Attachment 8 - M-2505 Asbestos Report.pdf
PDF 2 MB Posted
- Attached to
- Fort Bragg DPW Vertical Construction Federal contract opportunity
- Solicitation number
- W91247-20-R-0009
About this file
This document contains an asbestos survey report for Building M-2505 at Fort Bragg, North Carolina, and details for a related federal contract opportunity. The asbestos survey report documents an inspection of the building conducted in June 2016, and identifies transite pipe insulation elbows located behind a wall in the building's foyer area as the only asbestos containing material found. The report provides background on the building, inspection methodology, laboratory analysis results, and certifications of the inspector.
The related federal contract opportunity is solicitation number W91247-20-R-0009 from the Department of the Army Materiel Command Mission and Installation Contracting Command for vertical construction services at Fort Bragg. The indefinite-delivery/indefinite-quantity contract will be for maintenance, repair, and minor construction projects across various trades such as carpentry, roofing, electrical work, and plumbing. The scope includes new construction, maintenance and repair work, energy conservation, and general construction tasks to support Fort Bragg facilities.
View the file
Other files for this federal contract opportunity
Show all 48
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Building M-2505 Fort Bragg, NC
Asbestos Survey for Demolition of
Fort Bragg, North Carolina
Prepared by Solomon Locklear of Carolina Environmental Design, LLC, Inspector
License Number 12601 for
The Directorate of Public Works, Ft. Bragg, North Carolina
Asbestos Survey Report Introduction
Scope of the Investigation
This report documents the asbestos inspection and survey of Building M-2505, located at Fort Bragg, North Carolina conducted on June 7th, 2016, by Solomon Locklear, NC asbestos inspector license number: NC12601.
Background
Building M-2505 is a single story structure that was used on Ft. Bragg as a chapel. The chapel has an estimated construction date of 1941 with a square footage of 3,710 square feet. The exterior of the building is constructed out of wood siding with the roof system of the building constructed in an “A” roof shape that is covered with a layer of asphalt roof shingles and roof felt. The interior of the building is constructed out of wood, drywall and an acoustical fiberboard material. The flooring system of the building is constructed out of wood joist that also has a layer of plywood and hardwood throughout the chapel. The HVAC system is located in the exterior of the mechanical room. The mechanical room has drywall/joint compound and concrete present throughout. The original HVAC system has been replaced with a newer system, but some of the original piping is still present in the chapel.
Conclusions
Asbestos was not detected in the following materials:
Asphalt Roof Shingle Roof Felt Wall/Ceiling Texture Material Drywall Concrete Panel Material
Asbestos detected in the following materials:
TSI Pipe Insulation Elbow
Limitations
As is the case with any asbestos inspection, materials that were not readily apparent or were located in concealed locations may not have been identified. If any material that is suspected to contain asbestos, and was not included in this report as a material identified and tested, is discovered, it should be evaluated for asbestos content before it is disturbed.
This report is not intended for use as an asbestos removal specification. It is not within the scope of this work to describe all appropriate precautions, safeguards and regulations relating to asbestos.
Sole Use Statement
This report is provided for the sole use of the Directorate of Public Works at Ft. Bragg. Reliance on this report by any third parties will be at such party’s sole risk, and Carolina Environmental Designs the survey disclaims liability for any use of or reliance on this report by third parties. All portions of this report, including attachments and figures, are interrelated and integral to this report and should not be transmitted independent of each other.
Photo of Asbestos Containing Material
TSI Pipe Insulation Elbows TSI Pipe Insulation Elbow Material Has Fallen From Original Position
Asbestos Containing Materials
MATERIAL CHARACTERISTICS ASSESSMENT
Sample Type Homogenous Area Description/Location
% Asbestos Yes/No/Presumed
Quantity/Type (If ACM)
Friable / Non-Friable Condition Disturbance
Potential
TSI
TSI Pipe Insulation Elbow
Located Behind Wall in Foyer Area of Chapel
Asbestos Detected 35% Asbestos
Chrysotile Undetermined
Amount Friable Poor
Laboratory Reports and Chain of Custody Forms
Sample Locations
Certifications and Accreditations
| Asbestos Survey for Demolition of |
| Building M-2505 |
| Fort Bragg, North Carolina |
| Introduction |
| Scope of the Investigation |
| Background |
| Conclusions |
| Limitations |
| Sole Use Statement |
| Asbestos Containing Materials |
| Laboratory Reports and Chain of Custody Forms |
| Sample Locations |
| Certifications and Accreditations |
File details come from the government source that posted it. Updated .