This solicitation is seeking a contractor to perform HVAC repairs, exterior wall repairs and modifications, fire alarm system work, sealant replacement, and metal roof repairs and modifications at NNPTC BEQ Building 2403 and 2404 at Joint Base Charleston in South Carolina. The project magnitude is estimated between $5,000,000 to $10,000,000. The solicitation is set aside for SDVOSBs and will use trade-off source selection procedures. The NAICS code for this opportunity is 236220. The closing date is TBD and notice of award is expected within 45 days of closing, with a notice to proceed to be issued within 60 days of award. The Department of the Air Force Air Mobility Command is the contracting agency. Any questions should be directed to the point of contact provided.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NEW MANUFACTURER OVER MOUNTING OR

SYMBOL OR PART DESCRIPTION MANUFACTURER ALL ROUGH IN

EXISTING NUMBER QTY REQUIREMENTS

NEW 708-031-00 SINGLE ACTION MANUAL PULL STATION MONACO

4 INCH SQUARE BOX -

2-1/8" DEEP WITH

SINGLE GANG RING

NEW M501M ADDRESSABLE MINI MONITOR MODULE SYSTEM SENSOR

4 INCH SQUARE BOX 2-

1/8" SQUARE

W/EXTENSION

NEW 2251B PHOTOELECTRIC SMOKE DETECTOR SYSTEM SENSOR

SEE SPECIFIED BASE OR

HOUSING

NEW B210LP FLANGED MOUNTING BASE SYSTEM SENSOR

4 INCH SQUARE BOX

W/ SINGLE GANG

RING

NEW 2251B PHOTOELECTRIC SMOKE DETECTOR SYSTEM SENSOR

SEE SPECIFIED BASE OR

HOUSING

NEW B200S-LF-IV INTELLIGENT PROGRAMMABLE LOW FREQUENCY SOUNDER BASE SYSTEM SENSOR

4 INCH SQUARE 2-1/8"

DEEP

NEW DNR PHOTO SMOKE DUCT HOUSING - NO RELAY SYSTEM SENSOR - - -

NEW 2251BR REMOTE TEST CAPABLE ADDRESSABLE LOW-PRO-FILE

PHOTOELECTRIC SMOKE DETECTOR

SYSTEM SENSOR

SEE SPECIFIED BASE OR

HOUSING

NEW RTS151KEY REMOTE TEST STATION WITH KEY SYSTEM SENSOR 20 SINGLE GANG BOX

NEW CO1224TR CARBON MONOXIDE DETECTOR SYSTEM SENSOR

4 INCH SQUARE BOX

W/ SINGLE GANG

RING

NEW M501M ADDRESSABLE MINI MONITOR MODULE SYSTEM SENSOR

4 INCH SQUARE BOX 2-

1/8" SQUARE

W/EXTENSION

NEW M500M ADDRESSABLE MONITOR MODULE SYSTEM SENSOR 2

4 INCH SQUARE BOX -

2-1/8" DEEP

W/EXTENSION

NEW M500DM INTELLIGENT DUAL MONITOR MODULE SYSTEM SENSOR 16

4 INCH SQUARE 2-1/8"

DEEP W/EXTENSION

RING

NEW M500R ADDRESSABLE RELAY MODULE SYSTEM SENSOR 12

4 INCH SQUARE BOX -

2-1/8" DEEP

W/EXTENSION

NEW BB-2 2 MODULE ENCLOSURE SYSTEM SENSOR 2 4.9" H x 3.3" W x 1.9" D

NEW IM-10 CLIP PROTOCOL INTELLIGENT TEN INPUT MONITOR MODULE SYSTEM SENSOR 4 SEE SPECIFIED

ENCLOSURE

NEW MR-101/T 10A ISOLATION RELAY - SPDT - TRACK MOUNTED AP&C 48 3.25" H x 2.125" W x 1.5" D

NEW SPSWL-CLR-ALERT (15cd) ALERT SPEAKERSTROBE - WALL - WHITE - 15cd SYSTEM SENSOR 28

4 INCH SQUARE BOX -

2-1/8" DEEP

W/EXTENSION

NEW SPSWL-CLR-ALERT (30cd) ALERT SPEAKERSTROBE - WALL - WHITE - 30cd SYSTEM SENSOR 3

4 INCH SQUARE BOX -

2-1/8" DEEP

W/EXTENSION

NEW SPSWL-CLR-ALERT (75cd) ALERT SPEAKERSTROBE - WALL - WHITE - 75cd SYSTEM SENSOR 3

4 INCH SQUARE BOX -

2-1/8" DEEP

W/EXTENSION

NEW SPSWL-CLR-ALERT (95cd) ALERT SPEAKERSTROBE - WALL - WHITE - 95cd SYSTEM SENSOR 0

4 INCH SQUARE BOX -

2-1/8" DEEP

W/EXTENSION

NEW SPSWL-CLR-ALERT (110cd) ALERT SPEAKERSTROBE - WALL - WHITE - 110cd SYSTEM SENSOR 0

4 INCH SQUARE BOX -

2-1/8" DEEP

W/EXTENSION

NEW SPSWL-CLR-ALERT (135cd) ALERT SPEAKERSTROBE - WALL - WHITE - 135cd SYSTEM SENSOR 0

4 INCH SQUARE BOX -

2-1/8" DEEP

W/EXTENSION

NEW SPSWL-CLR-ALERT (185cd) ALERT SPEAKERSTROBE - WALL - WHITE - 185cd SYSTEM SENSOR 0

4 INCH SQUARE BOX -

2-1/8" DEEP

W/EXTENSION

NEW SPWL SPEAKER ONLY - WALL - WHITE SYSTEM SENSOR 300

4 INCH SQUARE BOX 2-

1/8" DEEP

W/EXTENSION

NEW SPWK OUTDOOR WEATHERPROOF SPEAKER - WHITE SYSTEM SENSOR 96 WEATHERPROOF

BACKBOX INCLUDED

EXISTING SPRINKLER FLOW SWITCH

FURNISHED AND

INSTALLED BY OTHERS

EXISTING SPRINKLER TAMPER SWITCH

FURNISHED AND

INSTALLED BY OTHERS

EXISTING SPRINKLER PRESSURE SWITCH

FURNISHED AND

INSTALLED BY OTHERS

NEW MANUFACTURER OVER MOUNTING OR

SYMBOL OR PART DESCRIPTION MANUFACTURER ALL ROUGH IN

EXISTING NUMBER QTY REQUIREMENTS

NEW 227-955-XX MAAP-X COMBINATION FIRE/MNS CONTROL PANEL MONACO 1 28" H x 18" W x 3.6" D

NEW 176-276-00 MAAP-X CPU PCB MONACO 1 MOUNTS INSIDE PANEL

NEW 176-273-00 ANALOG ADDRESSABLE CONTROLLER II (AAC II) MONACO 1 MOUNTS INSIDE PANEL

NEW 176-271-00 MAAP-X CORE II PCB MONACO 1 MOUNTS IN AAC II

INSIDE PANEL

NEW 176-272-00 SPEAKER OUTPUT CARD (SOC) MONACO 1 MOUNTS IN AAC II

INSIDE PANEL

NEW 176-194-00 ADDRESSABLE DRIVER CARD (ADC) MONACO 6 MOUNTS IN AAC II

INSIDE PANEL

NEW 176-268-02 ISOLATED MULTIPLEXER KIT FOR LOC CONNECTION MONACO 1 MOUNTS INSIDE PANEL

NEW PS-12550 SEALED LEAD ACID BATTERY - 55Ah POWER SONIC 4 8.15" H x 5.45" W x 9.04" L

NEW 710-072-01 LOC/RDU WITH TOUCH SCREEN MONACO 1 - - -

NEW PS-12260 SEALED LEAD ACID BATTERY - 26Ah POWER SONIC 2 4.92" H x 6.97" W x 6.56" L

NEW SPB-320 320 WATT SUPERVISED AUDIO POWER BOOSTER WHEELOCK 1 36 " H x 24" W x 6" D

NEW SP4Z-A/B SUPERVISED SPEAKER AUDIO SPLITTER WHEELOCK 4 MOUNTED INSIDE

PANEL

NEW PS-12330 SEALED LEAD ACID BATTERY - 33Ah POWER SONIC 4 6.22" H x 5.14" W x 7.72" L

NEW SPB-320 320 WATT SUPERVISED AUDIO POWER BOOSTER WHEELOCK 1 36 " H x 24" W x 6" D

NEW SP4Z-A/B SUPERVISED SPEAKER AUDIO SPLITTER WHEELOCK 2 MOUNTED INSIDE

PANEL

NEW PS-12330 SEALED LEAD ACID BATTERY - 33Ah POWER SONIC 4 6.22" H x 5.14" W x 7.72" L

NEW PSN-106 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY POTTER 1 16-1/8" W x 16-3/4" H x 3-1/2" D

NEW PS-12330 SEALED LEAD ACID BATTERY - 33Ah POWER SONIC 2 6.22" H x 5.14" W x 7.72" L

NEW PSN-106 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY POTTER 1 16-1/8" W x 16-3/4" H x 3-1/2" D

NEW PS-12330 SEALED LEAD ACID BATTERY - 33Ah POWER SONIC 2 6.22" H x 5.14" W x 7.72" L

NEW PSN-106 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY POTTER 1 16-1/8" W x 16-3/4" H x 3-1/2" D

NEW PS-12330 SEALED LEAD ACID BATTERY - 33Ah POWER SONIC 2 6.22" H x 5.14" W x 7.72" L

NEW PSN-106 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY POTTER 1 16-1/8" W x 16-3/4" H x 3-1/2" D

NEW PS-12330 SEALED LEAD ACID BATTERY - 33Ah POWER SONIC 2 6.22" H x 5.14" W x 7.72" L

NEW PSN-106 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY POTTER 1 16-1/8" W x 16-3/4" H x 3-1/2" D

NEW PS-12120 SEALED LEAD ACID BATTERY - 12Ah POWER SONIC 2 3.66" H x 3.86" W x 5.94" L

NEW PSN-106 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY POTTER 1 16-1/8" W x 16-3/4" H x 3-1/2" D

NEW PS-12120 SEALED LEAD ACID BATTERY - 12Ah POWER SONIC 2 3.66" H x 3.86" W x 5.94" L

NEW PSN-106 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY POTTER 1 16-1/8" W x 16-3/4" H x 3-1/2" D

NEW PS-12120 SEALED LEAD ACID BATTERY - 12Ah POWER SONIC 2 3.66" H x 3.86" W x 5.94" L

NEW PSN-106 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY POTTER 1 16-1/8" W x 16-3/4" H x 3-1/2" D

NEW PS-12120 SEALED LEAD ACID BATTERY - 12Ah POWER SONIC 2 3.66" H x 3.86" W x 5.94" L

Barracks Buildng 2408

Circuit NUMBER NUMBER NUMBER NUMBER NUMBER CIRCUIT TOTAL SIGNAL LOSS ID OF OF SPKRS OF SPKRS OF SPKRS OF SPKRS VOLTAGE POWER Wire Gauge:

on DISTANCE SPEAKERS TAPPED AT TAPPED AT TAPPED AT TAPPED AT (25 / 70) LOAD 16

Floor Plan [ft] 1/4 [W] 1/2 [W] 1 [W] 2 [W] [V] [W] [dB]

1ST FLOOR - AREA A 1A:A1 800 28 20 1 7 70 25.00 -0.35

1ST FLOOR - AREA B 1A:A2 1200 44 5 30 9 70 34.25 -0.70

80.00 Panel Watts Available

59.25 Watts Used

20.75 Watts Remaining

1ST FLOOR - AREA C 1A:A3 1200 36 1 25 1 9 70 31.75 -0.65

1ST FLOOR - AREA D 1A:A4 1000 34 2 24 1 7 70 27.50 -0.47

80.00 Panel Watts Available

59.25 Watts Used

20.75 Watts Remaining

2ND FLOOR - AREA A 1A:A5 900 30 1 21 1 7 70 25.75 -0.40

2ND FLOOR - AREA B 1A:A6 1300 43 2 32 9 70 34.50 -0.76

80.00 Panel Watts Available

60.25 Watts Used

19.75 Watts Remaining

2ND FLOOR - AREA C 1A:A7 1300 39 1 29 9 70 32.75 -0.72

2ND FLOOR - AREA D 1A:A8 1100 34 2 24 1 7 70 27.50 -0.52

80.00 Panel Watts Available

60.25 Watts Used

19.75 Watts Remaining

3RD FLOOR - AREA A 1B:A1 1000 30 1 21 1 7 70 25.75 -0.44

3RD FLOOR - AREA B 1B:A2 1400 43 2 32 9 70 34.50 -0.82

80.00 Panel Watts Available

60.25 Watts Used

19.75 Watts Remaining

3RD FLOOR - AREA C 1B:A3 1400 39 1 29 9 70 32.75 -0.78

3RD FLOOR - AREA D A1:A4 1200 34 2 24 1 7 70 27.50 -0.57

80.00 Panel Watts Available

60.25 Watts Used

19.75 Watts Remaining

[W] = WATTS

[V] = VOLTS

[dB] = DECIBEL [ft] = FEET

VLine = voltage on line (typically 25 volts or 70 volts) RRef = wire resistance based on gauge of wire used (in ohms/ft.)

PLoss = power loss (in dB) PRated = power driven on line from the amplifier (in watts)

NOTE:

DUE TO SITE CONDITIONS SIGNAL CIRCUIT ROUTING CAN CHANGE FROM WHAT IS INDICATED

ON SHOP DRAWINGS.

Losses in wiring shall not be greater than -1dB

RL = wire gauge resistance (in ohms)

PLoss = 10 * Log [1 - ((2 * RL) / (2 * RL + (VLine squared / PRated))] RL = (RRef / 1000) * D

With variables defined as follows:

D = length of wire used (in feet)

* This is the MAXIMUM allowed value per speaker. For specific power tap, for individual speakers, see the floor plans.

METHOD USED TO CALCULATE SPEAKER POWER LOSS:

AMP:1A (SPB-320 - TOP AMPLIFIER - CIRCUIT 1) SPEAKER LOSS CALCULATIONS

AMP:1A (SPB-320 - TOP AMPLIFIER - CIRCUIT 2) SPEAKER LOSS CALCULATIONS

Joint Base Charleston

AMP:1B (SPB-320 - TOP AMPLIFIER - CIRCUIT 1) SPEAKER LOSS CALCULATIONS

AMP:1B (SPB-320 - TOP AMPLIFIER - CIRCUIT 2) SPEAKER LOSS CALCULATIONS

AMP:1A (SPB-320 - BOTTOM AMPLIFIER - CIRCUIT 1) SPEAKER LOSS CALCULATIONS

AMP:1A (SPB-320 - BOTTOM AMPLIFIER - CIRCUIT 2) SPEAKER LOSS CALCULATIONS

Standby Total Alarm Total Part Number Qty Description Current Standby Current Alarm

710-072-01 1 LOC/RDU WITH TOUCH SCREEN 0.235000 0.235000 0.235000 0.235000

Total Panel Standby 0.235000 Total Panel Alarm 0.235000

TOTAL STANDBY AMPS 0.24 AMPS

STANDBY HOURS 72 HOURS

STANDBY AMP HOURS 16.92 AMP HOURS

TOTAL ALARM AMPS 0.24 AMPS

ALARM MINUTES 15 MINUTES

ALARM AMP HOURS 0.06 AMP HOURS

TOTAL 16.98 AMP HOURS

20% DERATING FACTOR 20.37 AMP HOURS NEEDED

(2) 26 AH BATTERIES

Joint Base Charleston Barracks Buildng 2408 LOC BATTERY CALCULATION

PANEL EQUIPMENT

ACTUAL BATTERIES BEING SUPPLIED

BATTERY CABINET REQUIRED

Standby Total Alarm Total Part Number Qty Description Current Standby Current Alarm

SPB-320 1 320 WATT SUPERVISED AUDIO POWER BOOSTER 0.120000 0.120000 18.000000 18.000000

SP4Z-A/B 4 SUPERVISED SPEAKER AUDIO SPLITTER 0.015000 0.060000 0.015000 0.060000

Total Panel Stby 0.180000 Total Panel Alarm 18.060000

TOTAL STANDBY AMPS 0.18 AMPS

STANDBY HOURS 72 HOURS

STANDBY AMP HOURS 12.96 AMP HOURS

TOTAL ALARM AMPS 18.06 AMPS

ALARM MINUTES 15 MINUTES

ALARM AMP HOURS 4.52 AMP HOURS

TOTAL 17.48 AMP HOURS

20% DERATING FACTOR 20.97 AMP HOURS NEEDED

4 33 AH BATTERIES

BATTERY CABINET REQUIRED

ACTUAL BATTERIES TO BE INSTALLED

Joint Base Charleston Barracks Buildng 2408 AMP:1A BATTERY CALCULATION

RPS PANEL EQUIPMENT

Standby Total Alarm Total Part Number Qty Description Current Standby Current Alarm

SPB-320 1 320 WATT SUPERVISED AUDIO POWER BOOSTER 0.120000 0.120000 18.000000 18.000000

SP4Z-A/B 2 SUPERVISED SPEAKER AUDIO SPLITTER 0.015000 0.030000 0.015000 0.030000

Total Panel Stby 0.150000 Total Panel Alarm 18.030000

TOTAL STANDBY AMPS 0.15 AMPS

STANDBY HOURS 72 HOURS

STANDBY AMP HOURS 10.80 AMP HOURS

TOTAL ALARM AMPS 18.03 AMPS

ALARM MINUTES 15 MINUTES

ALARM AMP HOURS 4.51 AMP HOURS

TOTAL 15.31 AMP HOURS

20% DERATING FACTOR 18.37 AMP HOURS NEEDED

4 33 AH BATTERIES

ACTUAL BATTERIES TO BE INSTALLED

BATTERY CABINET REQUIRED

Joint Base Charleston Barracks Buildng 2408 AMP:1B BATTERY CALCULATION

RPS PANEL EQUIPMENT

Standby Total Alarm Total Part Number Qty Description Current Standby Current Alarm

227-955-XX 1 MAAP-X COMBINATION FIRE/MNS CONTROL PANEL 0.000000 0.000000 0.000000 0.000000

176-276-00 1 MAAP-X CPU PCB 0.363000 0.363000 10.000000 10.000000

176-273-00 1 ANALOG ADDRESSABLE CONTROLLER II (AAC II) 0.000000 0.000000 0.000000 0.000000

176-271-00 1 MAAP-X CORE II PCB 0.000000 0.000000 0.000000 0.000000

176-272-00 1 SPEAKER OUTPUT CARD (SOC) 0.042000 0.042000 1.330000 1.330000

176-194-00 6 ADDRESSABLE DRIVER CARD (ADC) 0.045000 0.270000 0.000000 0.000000

176-268-02 1 ISOLATED MULTIPLEXER KIT FOR LOC CONNECTION 0.000000 0.000000 0.000000 0.000000

Total Panel Standby 0.675000 Total Panel Alarm 11.330000

M501M 24 ADDRESSABLE MINI MONITOR MODULE 0.000400 0.009600 0.005500 0.132000

2251B 17 PHOTOELECTRIC SMOKE DETECTOR 0.000300 0.005100 0.006500 0.110500

2251B 300 PHOTOELECTRIC SMOKE DETECTOR 0.000300 0.090000 0.006500 1.950000

2251BR 20 REMOTE TEST CAPABLE ADDRESSABLE LOW-PRO-FILE PHOTOELECTRIC SMOKE DETECTOR 0.000300 0.006000 0.006500 0.130000

RTS151KEY 20 REMOTE TEST STATION WITH KEY 0.012000 0.240000 0.012000 0.240000

M501M 4 ADDRESSABLE MINI MONITOR MODULE 0.000400 0.001600 0.005500 0.022000

Total Initiating Standby 0.352300 Total Initiating Alarm 2.584500

M500M 2 ADDRESSABLE MONITOR MODULE 0.000550 0.001100 0.005500 0.011000

M500DM 16 INTELLIGENT DUAL MONITOR MODULE 0.000750 0.012000 0.006000 0.096000

M500R 12 ADDRESSABLE RELAY MODULE 0.000300 0.003600 0.005500 0.066000

BB-2 2 2 MODULE ENCLOSURE 0.000000 0.000000 0.000000 0.000000

IM-10 4 CLIP PROTOCOL INTELLIGENT TEN INPUT MONITOR MODULE 0.003500 0.014000 0.060000 0.240000

Total Module Standby 0.030700 Total Module Alarm 0.413000

TOTAL STANDBY AMPS 1.06 AMPS

STANDBY HOURS 72 HOURS

STANDBY AMP HOURS 76.18 AMP HOURS

TOTAL ALARM AMPS 14.33 AMPS

ALARM MINUTES 15 MINUTES

ALARM AMP HOURS 3.58 AMP HOURS

TOTAL 79.76 AMP HOURS

20% DERATING FACTOR 95.71 AMP HOURS NEEDED

(4) 55 AH BATTERIES

BATTERY CABINET REQUIRED

BATTERIES TO BE WIRED IN SERIES/PARALLEL

Joint Base Charleston Barracks Buildng 2408

PANEL EQUIPMENT

FAMNS BATTERY CALCULATION

INITIATING DEVICES

ACTUAL BATTERIES BEING SUPPLIED

MODULES, CONTROL DEVICES AND MISC.

SYSTEM INPUTS A

C

TU

A

TE

C

O M

M O

N A

LA

RM

S

IG

N A

L

IN

D

IC

A

TO

R

A C

TU

A

TE

A

U D

IB

LE

A

LA

RM

S

IG

N

A L

A C

TU

A

TE

C

O M

M O

N S

U

PE

RV

IS

O

RY

S

IG

N A

L

IN

D

IC

A

TO

R

A C

TU

A

TE

A

U D

IB

LE

S U

PE

RV

IS

O

RY

S

IG

N

A L

A C

TU

A

TE

C

O M

M O

N T

RO

U

BL

E

SI

G

N A

L

IN

D

IC

A

TO

R

A C

TU

A

TE

A

U D

IB

LE

C O

M M

O N

T

RO

U

BL

E

SI

G N

A L

D

IS

PL

A

Y D

EV

IC

E A

D D

RE

SS

/Z O

N E

O N

M A

IN

D

IS

PL

A Y

D

IS

PL

A

Y D

EV

IC

E A

D D

RE

SS

/Z O

N E

O N

A

LL

A N

N

UN

C

IA

TO

RS

A C

TI

V

A

TE

A

LL

V

IS

U A

L D

EV

IC

ES

T

H

RO

U G

H O

U T

BU

IL

D

IN

G

A C

TI

V

A

TE

A

LL

A U

D

IB

LE

D

EV

IC

ES

T

H

RO

U G

H O

U T

BU

IL

D

IN

G

A C

TI

V

A

TE

S O

U N

D

ER

B A

SE

W

IT

H

IN

R

O O

M O

F A

LA

RM

A C

TI

V

A

TE

C A

RB

O

N M

O N

O

XI

D E

(C O

SO

U N

D

ER

SI

LE

N C

E G

EN

ER

A L

FI

RE

A

LA

RM

A

N N

O U

N C

EM

EN

T

SH

U

TD

O

W N

A

SS

O C

IA

TE

D A

IR

H

A N

D

LE

R U

N

IT

TR

A

N

SM

IT

Z

O N

E

T

O B

A

SE

D

M

A N

U A

L

PU

LL

S

TA

TI

O N

TR

A

N

SM

IT

Z

O N

E

T

O B

A

SE

D

SM

O

KE

D

ET

EC

TO

R)

TR

A

N

SM

IT

Z

O N

E

T

O B

A

SE

D

H

EA

T

D

ET

EC

TO

R)

TR

A

N

SM

IT

Z

O N

E

T

O B

A

SE

D

D

U C

T D

ET

EC

TO

R)

TR

A

N

SM

IT

Z

O N

E

T

O B

A

SE

D

SP

RI

N

KL

ER

T A

M

PE

R

SW

IT

C

H

TR

A

N

SM

IT

Z

O N

E

T

O B

A

SE

D

SP

RI

N

KL

ER

F

LO

W S

W

IT

C H

TR

A

N

SM

IT

Z

O N

E

T

O B

A

SE

D

C

O D

ET

EC

TO

R)

TR

A

N

SM

IT

Z

O N

E

T

O B

A

SE

D

IN

R O

O M

S M

O

KE

D

ET

EC

TO

R)

TR

A

N

SM

IT

Z

O N

E

T

O B

A

SE

D

SP

A

RE

TR

A

N

SM

IT

Z

O N

E

T

O B

A

SE

D

SP

A

RE

TR

A

N

SM

IT

Z

O N

E

T

O B

A

SE

D

M

A

SS

N O

TI

FI

C A

TI

O

N

IN

PU

T)

TR

A

N

SM

IT

Z

O N

E

T

O B

A

SE

D

C

O M

M O

N T

RO

U

BL

E)

MANUAL PULL STATION X X X X X X X

AREA SMOKE DETECTOR X X X X X X X

IN ROOM SYSTEM SMOKE DETECTOR X X X X X X

MASS NOTIFICATION INPUT 1 - EMERGENCY, EVACUATE TO DESIGNATED AREA X X X X X X X X MASS NOTIFICATION INPUT 2 - BOMB THREAT, EVACUATE AT NEAREST EXIT X X X X X X X X

MASS NOTIFICATION INPUT 3 - SEVERE WEATHER WARNING X X X X X X X X

MASS NOTIFICATION INPUT 4 - INTRUDER, FOLLOW DESIGNATED PLAN X X X X X X X X

MASS NOTIFICATION INPUT 5 - SHELTER IN-PLACE X X X X X X X X X

MASS NOTIFICATION INPUT 6 - EMERGENCY, USE ALTERNATE EXIT X X X X X X X X

MASS NOTIFICATION INPUT 7 - EMERGENCY HAS ENDED X X X X X X X X

MASS NOTIFICATION INPUT 8 - TEST OF MONACO MASS NOTIFICATION SYSTEM X X X X X X X X

MASS NOTIFICATION INPUT 9 - CO DETECTED X X X X X X X X

MASS NOTIFICATION INPUT 10 - EMS DEDICATED FIRE MESSAGE X X X X X X X X

CARBON MONOXIDE (CO) DETECTOR X X X X X X X

DUCT DETECTOR - SUPPLY SIDE X X X X X X

DUCT DETECTOR - RETURN SIDE X X X X X X

SPRINKLER FLOW SWITCH X X X X X X X

SPRINKLER TAMPER SWITCH X X X

SPRINKLER PRESSURE SWITCH X X X X X

FAMNS CONTROL PANEL COMMON TROUBLE X X X X X

FAMNS CONTROL PANEL AC POWER FAILURE X X X X X

FAMNS CONTROL PANEL LOW BATTERY X X X X X

REMOTE AMPLIFIER COMMON TROUBLE X X X X X

REMOTE AMPLIFIER AC LOSS X X X X X

REMOTE POWER SUPPLY COMMON TROUBLE X X X X X

REMOTE POWER SUPPLY AC LOSS X X X X X

OPEN CIRCUIT X X X X X

GROUND FAULT X X X X X

NOTIFICATION APPIANCE CIRCUIT SHORT X X X X X

SIGNALS TO CENTRAL STATION MONITORINGCONTROL UNIT ANNUNCIATION IN BUILDING

NOTIFICATION

AUXILLARY

CONTROL

OUTPUTS

AMPERAGE TOTAL

CURRENT DRAW 01A:P1A 01A:P1B 01A:P2A 01A:P2B 01A:P3A 01A:P3B 01A:P4A 01A:P4B 01A:P5A 01A:P5B 01A:P6A 01A:P6B DEVICES

PART # DESCRIPTION CANDELA AT 16VDC

B200S-LF-IV 520Hz SOUNDER BASE - 0.050000 4 4 4 4 6 8 8 6 6 6 6 6 68

CO1224TR CO DETECTOR - 0.040000 2 2

MR-101/T ISOLATION RELAY - 0.018000 1 1 1 1 1 1 1 1 1 1 1 1 12

800 800 800 800 1200 1200 1200 1200 1200 1200 1200 1200

0.218 0.218 0.218 0.298 0.318 0.418 0.418 0.318 0.318 0.318 0.318 0.318

14 14 14 14 14 14 14 14 14 14 14 14

1.071 0.000 1.071 0.000 2.343 0.000 3.080 0.000 2.343 0.000 2.343 0.000 5.25% 5.25% 5.25% 7.18% 11.49% 15.10% 15.10% 11.49% 11.49% 11.49% 11.49% 11.49% 14.75% 14.75% 14.75% 12.82% 8.51% 4.90% 4.90% 8.51% 8.51% 8.51% 8.51% 8.51%

14GA = 0.003070

METHOD USED TO CALCULATE VOLTAGE DROP:

Vd = Vs - (I * ((R * 2 * L)/1,000))) Vd = Voltage Drop Vs = Starting Voltage (20.4 VDC, end of battery useful life) I = Total Load of Circuit in Amps R = Resistance in Ohms per 1000 feet

N.A.C. #06

0.436 0.516 0.736 0.736 0.636 0.636

N.A.C. #01 N.A.C. #02 N.A.C. #03 N.A.C. #04 N.A.C. #05

Joint Base Charleston RPS:01A VOLTAGE DROP CALCULATIONS Barracks Buildng 2408 ON BOARD NACS

TOTAL AMPS AVAILABLE 10

TOTAL AMPS USED 3.696

TOTAL AMPS REMAINING 6.304

STARTING VOLTAGE (FOR CALCULATIONS ONLY) 20.4

ESTIMATED CIRCUIT LENGTH

TOTAL LOAD PER BRANCH(AMPS)

TOTAL CIRCUIT LOAD (AMPS)

WIRE GAUGE (12,14,16,18)

L = Length Of Circuit In Feet

Wire Resistance At 75 Degrees Celsius Ohms/ft

ACTUAL VOLTAGE DROP (4.08 VOLTS MAXIMUM)

ACTUAL VOLTAGE DROP PERCENTAGE (20% MAXIMUM)

SPARE PERCENTAGE

Standby Total Alarm Total Part Number Qty Description Current Standby Current Alarm

PSN-106 1 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY 0.075000 0.075000 0.075000 0.075000

Total Panel Stby 0.075000 Total Panel Alarm 0.075000

B200S-LF-IV 68 INTELLIGENT PROGRAMMABLE LOW FREQUENCY SOUNDER BASE 0.000300 0.020400 0.050000 3.400000

CO1224TR 2 CARBON MONOXIDE DETECTOR 0.020000 0.040000 0.040000 0.080000

Total Device Stby 0.060400 Total Device Alarm 3.480000

MR-101/T 12 10A ISOLATION RELAY - SPDT - TRACK MOUNTED 0.018000 0.216000 0.018000 0.216000

Total Module Stby 0.216000 Total Module Alarm 0.216000

TOTAL STANDBY AMPS 0.35 AMPS

STANDBY HOURS 72 HOURS

STANDBY AMP HOURS 25.30 AMP HOURS

TOTAL ALARM AMPS 3.77 AMPS

ALARM MINUTES 15 MINUTES

ALARM AMP HOURS 0.94 AMP HOURS

TOTAL 26.24 AMP HOURS

20% DERATING FACTOR 31.49 AMP HOURS NEEDED

2 33 AH BATTERIES

Joint Base Charleston Barracks Buildng 2408 RPS:01A BATTERY CALCULATION

RPS PANEL EQUIPMENT

MODULES, CONTROL DEVICES AND MISC. REQUIRING POWER FROM THIS POWER SUPPLY

ACTUAL BATTERIES TO BE INSTALLED

BATTERY CABINET REQUIRED

INITIATING DEVICES AND BASES REQUIRING POWER FROM THIS POWER SUPPLY

AMPERAGE TOTAL

CURRENT DRAW 01B:P1A 01B:P1B 01B:P2A 01B:P2B 01B:P3A 01B:P3B 01B:P4A 01B:P4B 01B:P5A 01B:P5B 01B:P6A 01B:P6B DEVICES

PART # DESCRIPTION CANDELA AT 16VDC

B200S-LF-IV 520Hz SOUNDER BASE - 0.050000 8 4 4 8 6 4 4 6 8 8 8 8 76

CO1224TR CO DETECTOR - 0.040000 2 2

MR-101/T ISOLATION RELAY - 0.018000 1 1 1 1 1 1 1 1 1 1 1 1 12

1000 1000 1000 1000 900 900 900 900 1300 1300 1300 1300

0.418 0.218 0.218 0.498 0.318 0.218 0.218 0.318 0.418 0.418 0.418 0.418

14 14 14 14 14 14 14 14 14 14 14 14

2.567 0.000 1.339 0.000 1.757 0.000 1.205 0.000 3.336 0.000 3.336 0.000 12.58% 6.56% 6.56% 14.99% 8.61% 5.91% 5.91% 8.61% 16.36% 16.36% 16.36% 16.36% 7.42% 13.44% 13.44% 5.01% 11.39% 14.09% 14.09% 11.39% 3.64% 3.64% 3.64% 3.64%

14GA = 0.003070

METHOD USED TO CALCULATE VOLTAGE DROP:

Vd = Vs - (I * ((R * 2 * L)/1,000))) Vd = Voltage Drop Vs = Starting Voltage (20.4 VDC, end of battery useful life) I = Total Load of Circuit in Amps R = Resistance in Ohms per 1000 feet

N.A.C. #06

0.636 0.716 0.536 0.536 0.836 0.836

N.A.C. #01 N.A.C. #02 N.A.C. #03 N.A.C. #04 N.A.C. #05

Joint Base Charleston RPS:01B VOLTAGE DROP CALCULATIONS Barracks Buildng 2408 ON BOARD NACS

TOTAL AMPS AVAILABLE 10

TOTAL AMPS USED 4.096

TOTAL AMPS REMAINING 5.904

STARTING VOLTAGE (FOR CALCULATIONS ONLY) 20.4

ESTIMATED CIRCUIT LENGTH

TOTAL LOAD PER BRANCH(AMPS)

TOTAL CIRCUIT LOAD (AMPS)

WIRE GAUGE (12,14,16,18)

L = Length Of Circuit In Feet

Wire Resistance At 75 Degrees Celsius Ohms/ft

ACTUAL VOLTAGE DROP (4.08 VOLTS MAXIMUM)

ACTUAL VOLTAGE DROP PERCENTAGE (20% MAXIMUM)

SPARE PERCENTAGE

Standby Total Alarm Total Part Number Qty Description Current Standby Current Alarm

PSN-106 1 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY 0.075000 0.075000 0.075000 0.075000

Total Panel Stby 0.075000 Total Panel Alarm 0.075000

B200S-LF-IV 76 INTELLIGENT PROGRAMMABLE LOW FREQUENCY SOUNDER BASE 0.000300 0.022800 0.050000 3.800000

CO1224TR 2 CARBON MONOXIDE DETECTOR 0.020000 0.040000 0.040000 0.080000

Total Device Stby 0.062800 Total Device Alarm 3.880000

MR-101/T 12 10A ISOLATION RELAY - SPDT - TRACK MOUNTED 0.018000 0.216000 0.018000 0.216000

Total Module Stby 0.216000 Total Module Alarm 0.216000

TOTAL STANDBY AMPS 0.35 AMPS

STANDBY HOURS 72 HOURS

STANDBY AMP HOURS 25.47 AMP HOURS

TOTAL ALARM AMPS 4.17 AMPS

ALARM MINUTES 15 MINUTES

ALARM AMP HOURS 1.04 AMP HOURS

TOTAL 26.52 AMP HOURS

20% DERATING FACTOR 31.82 AMP HOURS NEEDED

2 33 AH BATTERIES

Joint Base Charleston Barracks Buildng 2408 RPS:01B BATTERY CALCULATION

RPS PANEL EQUIPMENT

MODULES, CONTROL DEVICES AND MISC. REQUIRING POWER FROM THIS POWER SUPPLY

ACTUAL BATTERIES TO BE INSTALLED

BATTERY CABINET REQUIRED

INITIATING DEVICES AND BASES REQUIRING POWER FROM THIS POWER SUPPLY

CURRENT DRAW 01C:P1A 01C:P1B 01C:P2A 01C:P2B 01C:P3A 01C:P3B 01C:P4A 01C:P4B 01C:P5A 01C:P5B 01C:P6A 01C:P6B DEVICES

PART # DESCRIPTION CANDELA AT 16VDC

B200S-LF-IV 520Hz SOUNDER BASE - 0.050000 8 6 6 8 8 4 4 8 5 4 4 7 72

CO1224TR CO DETECTOR - 0.040000 0

MR-101/T ISOLATION RELAY - 0.018000 1 1 1 1 1 1 1 1 1 1 1 1 12

1300 1300 1300 1300 1100 1100 1100 1100 1000 1000 1000 1000

0.418 0.318 0.318 0.418 0.418 0.218 0.218 0.418 0.268 0.218 0.218 0.368

14 14 14 14 14 14 14 14 14 14 14 14

3.336 0.000 2.538 0.000 2.823 0.000 1.472 0.000 1.646 0.000 1.339 0.000

16.36% 12.44% 12.44% 16.36% 13.84% 7.22% 7.22% 13.84% 8.07% 6.56% 6.56% 11.08% 3.64% 7.56% 7.56% 3.64% 6.16% 12.78% 12.78% 6.16% 11.93% 13.44% 13.44% 8.92%

14GA = 0.003070

L = Length Of Circuit In Feet

Wire Resistance At 75 Degrees Celsius Ohms/ft

ACTUAL VOLTAGE DROP (4.08 VOLTS MAXIMUM)

ACTUAL VOLTAGE DROP PERCENTAGE (20% MAXIMUM)

SPARE PERCENTAGE

WIRE GAUGE (12,14,16,18)

STARTING VOLTAGE (FOR CALCULATIONS ONLY) 20.4

ESTIMATED CIRCUIT LENGTH

TOTAL LOAD PER BRANCH(AMPS)

TOTAL CIRCUIT LOAD (AMPS)

TOTAL AMPS AVAILABLE 10

TOTAL AMPS USED 3.816

TOTAL AMPS REMAINING 6.184

Joint Base Charleston RPS:01C VOLTAGE DROP CALCULATIONS Barracks Buildng 2408 ON BOARD NACS

N.A.C. #06

0.736 0.736 0.636 0.636 0.486 0.586

N.A.C. #01 N.A.C. #02 N.A.C. #03 N.A.C. #04 N.A.C. #05

METHOD USED TO CALCULATE VOLTAGE DROP:

Vd = Vs - (I * ((R * 2 * L)/1,000))) Vd = Voltage Drop Vs = Starting Voltage (20.4 VDC, end of battery useful life) I = Total Load of Circuit in Amps R = Resistance in Ohms per 1000 feet

Standby Total Alarm Total Part Number Qty Description Current Standby Current Alarm

PSN-106 1 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY 0.075000 0.075000 0.075000 0.075000

Total Panel Stby 0.075000 Total Panel Alarm 0.075000

B200S-LF-IV 72 INTELLIGENT PROGRAMMABLE LOW FREQUENCY SOUNDER BASE 0.000300 0.021600 0.050000 3.600000

CO1224TR 0 CARBON MONOXIDE DETECTOR 0.020000 0.000000 0.040000 0.000000

Total Device Stby 0.021600 Total Device Alarm 3.600000

MR-101/T 12 10A ISOLATION RELAY - SPDT - TRACK MOUNTED 0.018000 0.216000 0.018000 0.216000

Total Module Stby 0.216000 Total Module Alarm 0.216000

TOTAL STANDBY AMPS 0.31 AMPS

STANDBY HOURS 72 HOURS

STANDBY AMP HOURS 22.51 AMP HOURS

TOTAL ALARM AMPS 3.89 AMPS

ALARM MINUTES 15 MINUTES

ALARM AMP HOURS 0.97 AMP HOURS

TOTAL 23.48 AMP HOURS

20% DERATING FACTOR 28.18 AMP HOURS NEEDED

2 33 AH BATTERIES

MODULES, CONTROL DEVICES AND MISC. REQUIRING POWER FROM THIS POWER SUPPLY

ACTUAL BATTERIES TO BE INSTALLED

BATTERY CABINET REQUIRED

INITIATING DEVICES AND BASES REQUIRING POWER FROM THIS POWER SUPPLY

Joint Base Charleston Barracks Buildng 2408 RPS:01C BATTERY CALCULATION

RPS PANEL EQUIPMENT

AMPERAGE TOTAL

CURRENT DRAW 01D:P1A 01D:P1B 01D:P2A 01D:P2B 01D:P3A 01D:P3B 01D:P4A 01D:P4B 01D:P5A 01D:P5B 01D:P6A 01D:P6B DEVICES

PART # DESCRIPTION CANDELA AT 16VDC

B200S-LF-IV 520Hz SOUNDER BASE - 0.050000 8 8 8 8 8 6 6 8 8 4 4 8 84

CO1224TR CO DETECTOR - 0.040000 0

MR-101/T ISOLATION RELAY - 0.018000 1 1 1 1 1 1 1 1 1 1 1 1 12

1400 1400 1400 1400 1400 1400 1400 1400 1200 1200 1200 1200

0.418 0.418 0.418 0.418 0.418 0.318 0.318 0.418 0.418 0.218 0.218 0.418

14 14 14 14 14 14 14 14 14 14 14 14

3.593 0.000 3.593 0.000 3.593 0.000 2.734 0.000 3.080 0.000 1.606 0.000

17.61% 17.61% 17.61% 17.61% 17.61% 13.40% 13.40% 17.61% 15.10% 7.87% 7.87% 15.10% 2.39% 2.39% 2.39% 2.39% 2.39% 6.60% 6.60% 2.39% 4.90% 12.13% 12.13% 4.90%

14GA = 0.003070

L = Length Of Circuit In Feet

Wire Resistance At 75 Degrees Celsius Ohms/ft

ACTUAL VOLTAGE DROP (4.08 VOLTS MAXIMUM)

ACTUAL VOLTAGE DROP PERCENTAGE (20% MAXIMUM)

SPARE PERCENTAGE

WIRE GAUGE (12,14,16,18)

STARTING VOLTAGE (FOR CALCULATIONS ONLY) 20.4

ESTIMATED CIRCUIT LENGTH

TOTAL LOAD PER BRANCH(AMPS)

TOTAL CIRCUIT LOAD (AMPS)

TOTAL AMPS AVAILABLE 10

TOTAL AMPS USED 4.416

TOTAL AMPS REMAINING 5.584

Joint Base Charleston RPS:01D VOLTAGE DROP CALCULATIONS Barracks Buildng 2408 ON BOARD NACS

N.A.C. #06

0.836 0.836 0.736 0.736 0.636 0.636

N.A.C. #01 N.A.C. #02 N.A.C. #03 N.A.C. #04 N.A.C. #05

METHOD USED TO CALCULATE VOLTAGE DROP:

Vd = Vs - (I * ((R * 2 * L)/1,000))) Vd = Voltage Drop Vs = Starting Voltage (20.4 VDC, end of battery useful life) I = Total Load of Circuit in Amps R = Resistance in Ohms per 1000 feet

Standby Total Alarm Total Part Number Qty Description Current Standby Current Alarm

PSN-106 1 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY 0.075000 0.075000 0.075000 0.075000

Total Panel Stby 0.075000 Total Panel Alarm 0.075000

B200S-LF-IV 84 INTELLIGENT PROGRAMMABLE LOW FREQUENCY SOUNDER BASE 0.000300 0.025200 0.050000 4.200000

CO1224TR 0 CARBON MONOXIDE DETECTOR 0.020000 0.000000 0.040000 0.000000

Total Device Stby 0.025200 Total Device Alarm 4.200000

MR-101/T 12 10A ISOLATION RELAY - SPDT - TRACK MOUNTED 0.018000 0.216000 0.018000 0.216000

Total Module Stby 0.216000 Total Module Alarm 0.216000

TOTAL STANDBY AMPS 0.32 AMPS

STANDBY HOURS 72 HOURS

STANDBY AMP HOURS 22.77 AMP HOURS

TOTAL ALARM AMPS 4.49 AMPS

ALARM MINUTES 15 MINUTES

ALARM AMP HOURS 1.12 AMP HOURS

TOTAL 23.89 AMP HOURS

20% DERATING FACTOR 28.67 AMP HOURS NEEDED

2 33 AH BATTERIES

MODULES, CONTROL DEVICES AND MISC. REQUIRING POWER FROM THIS POWER SUPPLY

ACTUAL BATTERIES TO BE INSTALLED

BATTERY CABINET REQUIRED

INITIATING DEVICES AND BASES REQUIRING POWER FROM THIS POWER SUPPLY

Joint Base Charleston Barracks Buildng 2408 RPS:01D BATTERY CALCULATION

RPS PANEL EQUIPMENT

CURRENT DRAW 01E:V1 CLASS A 01E:V3 CLASS A 01E:V5 CLASS A DEVICES

PART # DESCRIPTION CANDELA AT 16VDC RETURN RETURN RETURN

SPSWL-CLR-ALERT (15cd) WALL MOUNT SPEAKERSTROBE 15cd 0.043 2 6 2 10 SPSWL-CLR-ALERT (30cd) WALL MOUNT SPEAKERSTROBE 30cd 0.063 2 1 3 SPSWL-CLR-ALERT (75cd) WALL MOUNT SPEAKERSTROBE 75cd 0.107 1 1 2 SPSWL-CLR-ALERT (95cd) WALL MOUNT SPEAKERSTROBE 95cd 0.121 0 SPSWL-CLR-ALERT (110cd) WALL MOUNT SPEAKERSTROBE 110cd 0.148 0 SPSWL-CLR-ALERT (135cd) WALL MOUNT SPEAKERSTROBE 135cd 0.172 0 SPSWL-CLR-ALERT (185cd) WALL MOUNT SPEAKERSTROBE 185cd 0.222 0

800 1200 1200

0.319 0.000 0.321 0.000 0.193 0.000

14 14 14 14 14 14

1.567 0.000 2.365 0.000 1.422 0.000 7.68% 0.00% 11.59% 0.00% 6.97% 0.00% 12.32% 20.00% 8.41% 20.00% 13.03% 20.00%

14GA = 0.003070

L = Length Of Circuit In Feet

Wire Resistance At 75 Degrees Celsius Ohms/ft

ACTUAL VOLTAGE DROP (4.08 VOLTS MAXIMUM)

ACTUAL VOLTAGE DROP PERCENTAGE (20% MAXIMUM)

SPARE PERCENTAGE

WIRE GAUGE (12,14,16,18)

STARTING VOLTAGE (FOR CALCULATIONS ONLY) 20.4

ESTIMATED CIRCUIT LENGTH

TOTAL LOAD PER BRANCH(AMPS)

TOTAL AMPS AVAILABLE 10

TOTAL AMPS USED 0.833

TOTAL AMPS REMAINING 9.167

Joint Base Charleston RPS:01E VOLTAGE DROP CALCULATIONS Barracks Buildng 2408 ON BOARD NACS

N.A.C. #06N.A.C. #01 N.A.C. #02 N.A.C. #03 N.A.C. #04 N.A.C. #05

METHOD USED TO CALCULATE VOLTAGE DROP:

Vd = Vs - (I * ((R * 2 * L)/1,000))) Vd = Voltage Drop Vs = Starting Voltage (20.4 VDC, end of battery useful life) I = Total Load of Circuit in Amps R = Resistance in Ohms per 1000 feet

Standby Total Alarm Total Part Number Qty Description Current Standby Current Alarm

PSN-106 1 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY 0.075000 0.075000 0.075000 0.075000

Total Panel Stby 0.075000 Total Panel Alarm 0.075000

SPSWL-CLR-ALERT (15cd) 10 ALERT SPEAKERSTROBE - WALL - WHITE - 15cd 0.000000 0.000000 0.043000 0.430000

SPSWL-CLR-ALERT (30cd) 3 ALERT SPEAKERSTROBE - WALL - WHITE - 30cd 0.000000 0.000000 0.063000 0.189000

SPSWL-CLR-ALERT (75cd) 2 ALERT SPEAKERSTROBE - WALL - WHITE - 75cd 0.000000 0.000000 0.107000 0.214000

SPSWL-CLR-ALERT (95cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 95cd 0.000000 0.000000 0.121000 0.000000

SPSWL-CLR-ALERT (110cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 110cd 0.000000 0.000000 0.148000 0.000000

SPSWL-CLR-ALERT (135cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 135cd 0.000000 0.000000 0.172000 0.000000

SPSWL-CLR-ALERT (185cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 185cd 0.000000 0.000000 0.222000 0.000000

Total Not. Stby 0.000000 Total Not. Alarm 0.833000

TOTAL STANDBY AMPS 0.08 AMPS

STANDBY HOURS 72 HOURS

STANDBY AMP HOURS 5.40 AMP HOURS

TOTAL ALARM AMPS 0.91 AMPS

ALARM MINUTES 15 MINUTES

ALARM AMP HOURS 0.23 AMP HOURS

TOTAL 5.63 AMP HOURS

20% DERATING FACTOR 6.75 AMP HOURS NEEDED

2 12 AH BATTERIES

ACTUAL BATTERIES TO BE INSTALLED

NOTIFICATION DEVICES

Joint Base Charleston Barracks Buildng 2408 RPS:01E BATTERY CALCULATION

RPS PANEL EQUIPMENT

AMPERAGE TOTAL

CURRENT DRAW 01F:V1 CLASS A 01F:V3 CLASS A 01F:V5 CLASS A DEVICES

PART # DESCRIPTION CANDELA AT 16VDC RETURN RETURN RETURN

SPSWL-CLR-ALERT (15cd) WALL MOUNT SPEAKERSTROBE 15cd 0.043 2 2 2 6 SPSWL-CLR-ALERT (30cd) WALL MOUNT SPEAKERSTROBE 30cd 0.063 0 SPSWL-CLR-ALERT (75cd) WALL MOUNT SPEAKERSTROBE 75cd 0.107 1 1 SPSWL-CLR-ALERT (95cd) WALL MOUNT SPEAKERSTROBE 95cd 0.121 0 SPSWL-CLR-ALERT (110cd) WALL MOUNT SPEAKERSTROBE 110cd 0.148 0 SPSWL-CLR-ALERT (135cd) WALL MOUNT SPEAKERSTROBE 135cd 0.172 0 SPSWL-CLR-ALERT (185cd) WALL MOUNT SPEAKERSTROBE 185cd 0.222 0

1000 900 1300

0.193 0.000 0.086 0.000 0.086 0.000

14 14 14 14 14 14

1.185 0.000 0.475 0.000 0.686 0.000 5.81% 0.00% 2.33% 0.00% 3.36% 0.00% 14.19% 20.00% 17.67% 20.00% 16.64% 20.00%

14GA = 0.003070

L = Length Of Circuit In Feet

Wire Resistance At 75 Degrees Celsius Ohms/ft

ACTUAL VOLTAGE DROP (4.08 VOLTS MAXIMUM)

ACTUAL VOLTAGE DROP PERCENTAGE (20% MAXIMUM)

SPARE PERCENTAGE

WIRE GAUGE (12,14,16,18)

STARTING VOLTAGE (FOR CALCULATIONS ONLY) 20.4

ESTIMATED CIRCUIT LENGTH

TOTAL LOAD PER BRANCH(AMPS)

TOTAL AMPS AVAILABLE 10

TOTAL AMPS USED 0.365

TOTAL AMPS REMAINING 9.635

Joint Base Charleston RPS:01F VOLTAGE DROP CALCULATIONS Barracks Buildng 2408 ON BOARD NACS

N.A.C. #06N.A.C. #01 N.A.C. #02 N.A.C. #03 N.A.C. #04 N.A.C. #05

METHOD USED TO CALCULATE VOLTAGE DROP:

Vd = Vs - (I * ((R * 2 * L)/1,000))) Vd = Voltage Drop Vs = Starting Voltage (20.4 VDC, end of battery useful life) I = Total Load of Circuit in Amps R = Resistance in Ohms per 1000 feet

Standby Total Alarm Total Part Number Qty Description Current Standby Current Alarm

PSN-106 1 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY 0.075000 0.075000 0.075000 0.075000

Total Panel Stby 0.075000 Total Panel Alarm 0.075000

SPSWL-CLR-ALERT (15cd) 6 ALERT SPEAKERSTROBE - WALL - WHITE - 15cd 0.000000 0.000000 0.043000 0.258000

SPSWL-CLR-ALERT (30cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 30cd 0.000000 0.000000 0.063000 0.000000

SPSWL-CLR-ALERT (75cd) 1 ALERT SPEAKERSTROBE - WALL - WHITE - 75cd 0.000000 0.000000 0.107000 0.107000

SPSWL-CLR-ALERT (95cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 95cd 0.000000 0.000000 0.121000 0.000000

SPSWL-CLR-ALERT (110cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 110cd 0.000000 0.000000 0.148000 0.000000

SPSWL-CLR-ALERT (135cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 135cd 0.000000 0.000000 0.172000 0.000000

SPSWL-CLR-ALERT (185cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 185cd 0.000000 0.000000 0.222000 0.000000

Total Not. Stby 0.000000 Total Not. Alarm 0.365000

TOTAL STANDBY AMPS 0.08 AMPS

STANDBY HOURS 72 HOURS

STANDBY AMP HOURS 5.40 AMP HOURS

TOTAL ALARM AMPS 0.44 AMPS

ALARM MINUTES 15 MINUTES

ALARM AMP HOURS 0.11 AMP HOURS

TOTAL 5.51 AMP HOURS

20% DERATING FACTOR 6.61 AMP HOURS NEEDED

2 12 AH BATTERIES

ACTUAL BATTERIES TO BE INSTALLED

NOTIFICATION DEVICES

Joint Base Charleston Barracks Buildng 2408 RPS:01F BATTERY CALCULATION

CURRENT DRAW 01G:V1 CLASS A 01G:V3 CLASS A 01G:V5 CLASS A DEVICES

PART # DESCRIPTION CANDELA AT 16VDC RETURN RETURN RETURN

SPSWL-CLR-ALERT (15cd) WALL MOUNT SPEAKERSTROBE 15cd 0.043 2 2 2 6 SPSWL-CLR-ALERT (30cd) WALL MOUNT SPEAKERSTROBE 30cd 0.063 0 SPSWL-CLR-ALERT (75cd) WALL MOUNT SPEAKERSTROBE 75cd 0.107 0 SPSWL-CLR-ALERT (95cd) WALL MOUNT SPEAKERSTROBE 95cd 0.121 0 SPSWL-CLR-ALERT (110cd) WALL MOUNT SPEAKERSTROBE 110cd 0.148 0 SPSWL-CLR-ALERT (135cd) WALL MOUNT SPEAKERSTROBE 135cd 0.172 0 SPSWL-CLR-ALERT (185cd) WALL MOUNT SPEAKERSTROBE 185cd 0.222 0

1300 1100 1000

0.086 0.000 0.086 0.000 0.086 0.000

14 14 14 14 14 14

0.686 0.000 0.581 0.000 0.528 0.000 3.36% 0.00% 2.85% 0.00% 2.59% 0.00% 16.64% 20.00% 17.15% 20.00% 17.41% 20.00%

14GA = 0.003070

L = Length Of Circuit In Feet

Wire Resistance At 75 Degrees Celsius Ohms/ft

ACTUAL VOLTAGE DROP (4.08 VOLTS MAXIMUM)

ACTUAL VOLTAGE DROP PERCENTAGE (20% MAXIMUM)

SPARE PERCENTAGE

WIRE GAUGE (12,14,16,18)

STARTING VOLTAGE (FOR CALCULATIONS ONLY) 20.4

ESTIMATED CIRCUIT LENGTH

TOTAL LOAD PER BRANCH(AMPS)

TOTAL AMPS AVAILABLE 10

TOTAL AMPS USED 0.258

TOTAL AMPS REMAINING 9.742

Joint Base Charleston RPS:01G VOLTAGE DROP CALCULATIONS Barracks Buildng 2408 ON BOARD NACS

N.A.C. #06N.A.C. #01 N.A.C. #02 N.A.C. #03 N.A.C. #04 N.A.C. #05

METHOD USED TO CALCULATE VOLTAGE DROP:

Vd = Vs - (I * ((R * 2 * L)/1,000))) Vd = Voltage Drop Vs = Starting Voltage (20.4 VDC, end of battery useful life) I = Total Load of Circuit in Amps R = Resistance in Ohms per 1000 feet

Standby Total Alarm Total Part Number Qty Description Current Standby Current Alarm

PSN-106 1 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY 0.075000 0.075000 0.075000 0.075000

Total Panel Stby 0.075000 Total Panel Alarm 0.075000

SPSWL-CLR-ALERT (15cd) 6 ALERT SPEAKERSTROBE - WALL - WHITE - 15cd 0.000000 0.000000 0.043000 0.258000

SPSWL-CLR-ALERT (30cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 30cd 0.000000 0.000000 0.063000 0.000000

SPSWL-CLR-ALERT (75cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 75cd 0.000000 0.000000 0.107000 0.000000

SPSWL-CLR-ALERT (95cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 95cd 0.000000 0.000000 0.121000 0.000000

SPSWL-CLR-ALERT (110cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 110cd 0.000000 0.000000 0.148000 0.000000

SPSWL-CLR-ALERT (135cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 135cd 0.000000 0.000000 0.172000 0.000000

SPSWL-CLR-ALERT (185cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 185cd 0.000000 0.000000 0.222000 0.000000

Total Not. Stby 0.000000 Total Not. Alarm 0.258000

TOTAL STANDBY AMPS 0.08 AMPS

STANDBY HOURS 72 HOURS

STANDBY AMP HOURS 5.40 AMP HOURS

TOTAL ALARM AMPS 0.33 AMPS

ALARM MINUTES 15 MINUTES

ALARM AMP HOURS 0.08 AMP HOURS

TOTAL 5.48 AMP HOURS

20% DERATING FACTOR 6.58 AMP HOURS NEEDED

2 12 AH BATTERIES

ACTUAL BATTERIES TO BE INSTALLED

NOTIFICATION DEVICES

Joint Base Charleston Barracks Buildng 2408 RPS:01G BATTERY CALCULATION

RPS PANEL EQUIPMENT

AMPERAGE TOTAL

CURRENT DRAW 01H:V1 CLASS A 01H:V3 CLASS A 01H:V5 CLASS A DEVICES

PART # DESCRIPTION CANDELA AT 16VDC RETURN RETURN RETURN

SPSWL-CLR-ALERT (15cd) WALL MOUNT SPEAKERSTROBE 15cd 0.043 2 2 2 6 SPSWL-CLR-ALERT (30cd) WALL MOUNT SPEAKERSTROBE 30cd 0.063 0 SPSWL-CLR-ALERT (75cd) WALL MOUNT SPEAKERSTROBE 75cd 0.107 0 SPSWL-CLR-ALERT (95cd) WALL MOUNT SPEAKERSTROBE 95cd 0.121 0 SPSWL-CLR-ALERT (110cd) WALL MOUNT SPEAKERSTROBE 110cd 0.148 0 SPSWL-CLR-ALERT (135cd) WALL MOUNT SPEAKERSTROBE 135cd 0.172 0 SPSWL-CLR-ALERT (185cd) WALL MOUNT SPEAKERSTROBE 185cd 0.222 0

1400 1400 1200

0.086 0.000 0.086 0.000 0.086 0.000

14 14 14 14 14 14

0.739 0.000 0.739 0.000 0.634 0.000 3.62% 0.00% 3.62% 0.00% 3.11% 0.00% 16.38% 20.00% 16.38% 20.00% 16.89% 20.00%

14GA = 0.003070

L = Length Of Circuit In Feet

Wire Resistance At 75 Degrees Celsius Ohms/ft

ACTUAL VOLTAGE DROP (4.08 VOLTS MAXIMUM)

ACTUAL VOLTAGE DROP PERCENTAGE (20% MAXIMUM)

SPARE PERCENTAGE

WIRE GAUGE (12,14,16,18)

STARTING VOLTAGE (FOR CALCULATIONS ONLY) 20.4

ESTIMATED CIRCUIT LENGTH

TOTAL LOAD PER BRANCH(AMPS)

TOTAL AMPS AVAILABLE 10

TOTAL AMPS USED 0.258

TOTAL AMPS REMAINING 9.742

Joint Base Charleston RPS:01H VOLTAGE DROP CALCULATIONS Barracks Buildng 2408 ON BOARD NACS

N.A.C. #06N.A.C. #01 N.A.C. #02 N.A.C. #03 N.A.C. #04 N.A.C. #05

METHOD USED TO CALCULATE VOLTAGE DROP:

Vd = Vs - (I * ((R * 2 * L)/1,000))) Vd = Voltage Drop Vs = Starting Voltage (20.4 VDC, end of battery useful life) I = Total Load of Circuit in Amps R = Resistance in Ohms per 1000 feet

Standby Total Alarm Total Part Number Qty Description Current Standby Current Alarm

PSN-106 1 10 AMP, 6 OUTPUT REMOTE POWER SUPPLY 0.075000 0.075000 0.075000 0.075000

Total Panel Stby 0.075000 Total Panel Alarm 0.075000

SPSWL-CLR-ALERT (15cd) 6 ALERT SPEAKERSTROBE - WALL - WHITE - 15cd 0.000000 0.000000 0.043000 0.258000

SPSWL-CLR-ALERT (30cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 30cd 0.000000 0.000000 0.063000 0.000000

SPSWL-CLR-ALERT (75cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 75cd 0.000000 0.000000 0.107000 0.000000

SPSWL-CLR-ALERT (95cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 95cd 0.000000 0.000000 0.121000 0.000000

SPSWL-CLR-ALERT (110cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 110cd 0.000000 0.000000 0.148000 0.000000

SPSWL-CLR-ALERT (135cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 135cd 0.000000 0.000000 0.172000 0.000000

SPSWL-CLR-ALERT (185cd) 0 ALERT SPEAKERSTROBE - WALL - WHITE - 185cd 0.000000 0.000000 0.222000 0.000000

Total Not. Stby 0.000000 Total Not. Alarm 0.258000

TOTAL STANDBY AMPS 0.08 AMPS

STANDBY HOURS 72 HOURS

STANDBY AMP HOURS 5.40 AMP HOURS

TOTAL ALARM AMPS 0.33 AMPS

ALARM MINUTES 15 MINUTES

ALARM AMP HOURS 0.08 AMP HOURS

TOTAL 5.48 AMP HOURS

20% DERATING FACTOR 6.58 AMP HOURS NEEDED

2 12 AH BATTERIES

ACTUAL BATTERIES TO BE INSTALLED

NOTIFICATION DEVICES

Joint Base Charleston Barracks Buildng 2408 RPS:01H BATTERY CALCULATION

WIRETAG CIRCUIT TYPE CIRCUIT DESCRIPTION WIRE EXAMPLE

(1) 18/2 SOLID TWISTED PAIR NON-SHIELDED RED (+) & BLACK (-) RS-485

(1) 14/2 SOLID TWISTED PAIR NON-SHIELDED RED (+) & BLACK (-) 24VDC AUX POWER

D1 SIGNALING LINE CIRCUIT (SLC) LOOP 1 -

1ST FLR - AREAS A AND B

D2 SIGNALING LINE CIRCUIT (SLC) LOOP 2 -

1ST FLR AREAS C AND D

D3 SIGNALING LINE CIRCUIT (SLC) LOOP 3 -

2ND FLR AREAS A AND B

D4 SIGNALING LINE CIRCUIT (SLC) LOOP 4 -

2ND FLR AREAS C AND D

D5 SIGNALING LINE CIRCUIT (SLC) LOOP 5 -

3RD FLR AREAS A AND B

D6 SIGNALING LINE CIRCUIT (SLC) LOOP 6 -

3RD FLR AREAS C AND D

Z MONITORING CIRCUIT FPL CABLE FPLR CABLE (1) 18/2 SOLID TWISTED PAIR NON-SHIELDED RED & BLACK FLOW, TAMPER, ANSUL, RPS, ETC

MONITORING

N NOTIFICATION APPLIANCE CIRCUIT

(N.A.C.) RPS TRIGGER CIRCUIT FPL CABLE FPLR CABLE (1) 14/2 SOLID TWISTED PAIR NON-SHIELDED RED (+) & BLACK (-) N.A.C. FROM FAMNS FOR RPS

TRIGGER CIRCUIT

V1 VISUAL N.A.C. #01

V3 VISUAL N.A.C. #03

V5 VISUAL N.A.C. #05

A AUDIO CIRCUIT FROM FAMNS PANEL

FOR REMOTE AMP TRIGGER FPL CABLE FPLR CABLE (1) 14/2 SOLID TWISTED PAIR NON-SHIELDED RED (+) & BLACK (-) AUDIO TRIGGER FROM FAMNS

PANEL

A1 AUDIO N.A.C. #01

A2 AUDIO N.A.C. #02

A3 AUDIO N.A.C. #03

A4 AUDIO N.A.C. #04

A5 AUDIO N.A.C. #05

A6 AUDIO N.A.C. #06

A7 AUDIO N.A.C. #07

A8 AUDIO N.A.C. #08

P1A 24VDC FROM OUTPUT #01

P1B 24VDC FROM OUTPUT #01

P2A 24VDC FROM OUTPUT #02

P2B 24VDC FROM OUTPUT #02

P3A 24VDC FROM OUTPUT #03

P3B 24VDC FROM OUTPUT #03

P4A 24VDC FROM OUTPUT #04

P4B 24VDC FROM OUTPUT #04

P5A 24VDC FROM OUTPUT #05

P5B 24VDC FROM OUTPUT #05

P6A 24VDC FROM OUTPUT #06

P6B 24VDC FROM OUTPUT #06

RLY RELAY CIRCUIT FPL CABLE FPLR CABLE (1) 18/4 SOLID TWISTED PAIR NON-SHIELDED RELAY CIRCUIT FOR FAN

SHUTDOWN

RTS REMOTE TEST SWITCH FPL CABLE FPLR CABLE (1) 18/4 SOLID TWISTED PAIR NON-SHIELDED RTS CIRCUIT FROM DUCT

DETECTOR

FPLR COMBO

CABLE

CABLE WIRE LEGEND

LOC LOCAL OPERATORS CONSOLE (LOC)

CIRCUIT

FPL COMBO

CABLE

FPL CABLE FPLR CABLE

&SOLID TWISTED PAIR NON-SHIELDED RED (+)14/224VDC AUX POWER CIRCUITS

(CONSTANT)

(1)VISUAL NOTIFICATION APPLIANCE

CIRCUIT (N.A.C.) RED (+)

(1) 16/2 SOLID TWISTED PAIR NON-SHIELDED RED (+)

14/2 SOLID TWISTED PAIR NON-SHIELDED

CABLE COLORS

RED (+) & BLACK (-)

BLACK (-)

ADDRESSABLE INITIATING DEVICES

BLACK (-)

FPLR CABLE

3/4" EMT CONDUIT - MASS NOTIFICATION CONDUIT

BLACK (-)

CONDUIT LEGEND

3/4" EMT CONDUIT - FIRE ALARM CONDUIT

FPL CABLE FPLR CABLE (1)

AUDIO NOTIFICATION APPLIANCE

CIRCUIT (N.A.C.) FPL CABLE

FPL CABLE FPLR CABLE (1) 18/2 SOLID TWISTED PAIR NON-SHIELDED

CABLE TYPE CABLE DESCRIPTION

01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38