Attachment 7 - EP401 ENLARGED ELECTRICAL PLANS.pdf
PDF 208 KB Posted
- Attached to
- Y1MG--654-19-3-6360-0025, Construction, 654-19-914, Solar Panels New Parking Garage, (VA-19-00049803)
- Solicitation number
- 36C77621R0077
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C77621R0077 0001.docx | DOCX document | |
| Attachment 8 - Wage Determination SCA - WASHOE - 12-21-20.txt | TXT text file | |
| Attachment 9 - Wage Determination DBA - WASHOE - 2-12-21.txt | TXT text file | |
| Attachment 6 - EP101 POWER _ SIGNAL PLANS - LEVEL 1.pdf | ||
| 36C77621R0077_1.docx | DOCX document | |
| Attachment 3 - SI001 - GENERAL NOTES -STRUCTURAL.pdf | ||
| Attachment 2 - Specs.zip | ZIP file | |
| Attachment 4 - Contractor Safety and Environmental Record Evaluation Form.docx | DOCX document | |
| Attachment 1 - SOW - Reno Solar Array DB.docx | DOCX document | |
| Attachment 5 - Release of Claims.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
F F
S m
J
10 11
F
E
B
C
TELECOM
AND
SECURITY
ELECTRICAL
STORAGE
STORAGE
ACI
FIRE ALARM JUNCTION BOX
EM INVERTER
(BELOW)
ACI
'(F) PV INVERTER'
'PVPB-3'
PBLN1A -[24,N]G
'PBLN1A'
'SE015'
PBLN1A -[18,N]G
10 12
TELECOM RACKS
'PBLELS1A'
LCP-1
'ACCESS CONTROL PANEL'
PBLN1A-[10,12,2N]G
RCC-1
(F) ACCESS CONTROL
PBLN1A -[26,N]G
PBLN1A -[28,N]G
PBLN1A -[22,N]G
PBLN1A -[16,N]G
PBLN1A -[14,N]G
B
A
ELEVATOR
ELEVATOR
MACHINE
BUSSMAN SWITCH (SEE ONELINE)
20A/1P FUSED DISC. SWITCH
ELEVATOR
CONTROLLER
SP-1
AC1
PBLN1A -[20,N]G
PBLELS1A -[4,N]G
+60" AFG7
4 8
J-BOX FOR
ELEVATOR CAB
LIGHTING
SPD
SE015 -[3,N]G
PBLN1A -[32,N]G121
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
Architect / Civil Engineer:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Structural Engineers: E/T Engineers:
CARL WALKER INC.
8910 Purdue Rd.
Suite 400 Indianapolis, IN 46268
Tele: 317.735.3349 POC: Doug Gannon
PK ELECTRICAL, INC.
681 Sierra Rose Drive Suite B Reno, NV 89511
Tele: 775.826.9010 POC: Jason Aviles
M/P Engineers:
AINSWORTH ASSOCIATES
1420 Holcomb Avenue Suite 201 Reno, NV 89502
Tele: 775.329.9100 POC: Roger Gravelle
GUIDON DESIGN INC.
905 North Capitol Avenue Suite 100 Indianapolis, IN 46204
Tele: 317.800.6388 POC: Stacey Paul
B
IM
/1
V A
R e n o P a rk in g G a ra g e /1
V A
R e n o P a rk in g G a ra g e
V .r v t
/1
/2
:2
:4
A
M
EP401
ENLARGED ELECTRICAL PLANS PARKING GARAGE DESIGN
RENO, NV
654-250
2018/03/05 JEG PKE
BID DOCUMENTS
NOT SPRINKLERED
C. Patrick Cassady, COR
EP401 Scale: 1/4" = 1'-0"
A
ENLARGED IT ROOM POWER &
SIGNAL PLAN
EP401 Scale: 1/4" = 1'-0"
B
ENLARGED ELEVATOR POWER &
SIGNAL PLAN - LEVEL 1
SHEET NOTES
1. ONLY EQUIPMENT AND WIRING ASSOCIATED WITH ELEVATOR EQUIPMENT IS PERMITTED WITHIN ELEVATOR MACHINE ROOM, NO EXCEPTIONS. REFER TO NEC, ARTICLE 620.37. ONLY PIPING, WIRING OR EQUIPMENT DIRECTLY RELATED TO ELEVATOR (i.e. ELEVATOR PIT SUMP, PIT LIGHT AND SWITCH, PIT RECEPTACLE, ETC) IS
PERMITTED.
2. ELEVATOR EQUIPMENT SHALL BE GROUNDED PER NEC, ARTICLE 620.82.
3. DISCONNECTING MEANS FOR ELEVATOR CONTROLS AND AUXILIARY EQUIPMENT (ELEVATOR CAR LIGHTS, POWER, VENTILATION AND HVAC) MUST BE CAPABLE OF BEING LOCKED IN THE OPEN POSITION. REFER TO NEC, ARTICLE 620.53 AND 620.54.
4. TELEPHONE SERVICE IS REQUIRED AT ELEVATOR CONTROLLER. REFER TO TELECOM DRAWINGS FOR MORE
INFORMATION AND COORDINATE WITH TELECOM CONTRACTOR.
5. COORDINATE WITH FIRE ALARM CONTRACTOR AND SIGNAL PLANS WITHIN THIS DRAWING PACKAGE FOR FIRE ALARM DEVICE REQUIREMENTS AND ELEVATOR EQUIPMENT CONNECTIONS TO FIRE ALARM SYSTEM / FACP.
6. HEAT DETECTORS LOCATED IN ELEVATOR EQUIPMENT ROOM SHALL HAVE A LOWER TEMPERATURE RATING AND
A HIGHER SENSITIVITY THAN THE SPRINKLER HEADS.
7. UPON ACTIVATION OF ANY AUTOMATIC FIRE DETECTION, THE ELEVATORS SHALL SIGNAL ELEVATOR RECALL TO
THE DESIGNATED LEVEL.
8. ELEVATOR ELECTRICAL INSTALLATIONS SHALL COMPLY WITH 14 24 00 AND DIVISION 26 SPECIFICATIONS.
GENERAL NOTES - ELEVATOR
GENERAL NOTES
PROVIDE RELAYS AND MONITOR MODULES FOR ELEVATOR INTEGRATION. COORDINATE WITH ELEVATOR
CONTRACTOR.
FUTURE ACCESS CONTROL BRANCH CIRCUIT. COORINATE WITH TELECOM DRAWING PRIOR TO FINAL
ROUGH-IN.
ELEVATOR CONTROLLER FURNISHED BY ELEVATOR CONTRACTOR. ELECTRICAL CONTRACTOR TO
COORDINATE FOR MAKING FINAL ELECTRICL CONNECTIONS.
PROVIDE A 240V, 3-POLE FUSED DISCONNECT SWITCH FOR ELEVATOR MAIN POWER SUPPLY BUSSMAN #PS6-100A-T20-R1-K-G-B-F3, EATON 'ES' SERIES, OR EQUAL UPON ENGINEER'S APPROVAL). DISCONNECT SWITCH SHALL BE PROVIDED WITH AN AUXILIARY CONTACT AND WIRED TO ELEVATOR CONTROLLER FOR CONTROL OF ERU (EMERGENCY RETURN UNIT). AUXILIARY CONTACT SHALL CAUSE ERU POWER SOURCE TO BE DISCONNECTED FROM ITS LOAD WHEN ELEVATOR MAIN POWER SUPPLY DISCONNECTING MEANS IS IN
THE OPEN POSITION.
PROVIDE A 1-POLE DISCONNECT SWITCH, LOCKABLE IN THE OPEN POSITION, FOR ELEVATOR CAB LIGHTS, POWER AND HVAC. COORDINATE FINAL CIRCUITING REQUIREMENTS WITH ELEVATOR CONTRACTOR PRIOR
TO ROUGH-IN.
RECEPTACLE FOR CORD-AND-PLUG SP-1 FLOAT SWITCHES AND ELEVATOR SHAFT LIGHTING. COORDINATE
FINAL LOCATION WITH PLUMBING CONTRACTOR PRIOR TO ROUGH-IN.
SUMP PUMP AUDIBLE VISUAL ALARM PROVIDED WITH SUMP PUMP SYSTEM (BY OTHERS). ELECTRICAL
CONTRACTOR TO COORDINATE FOR MAKING FINAL ELECTRICAL CONNECTIONS.
REFER TO ONELINE DIAGRAM FOR CONDUIT AND WIRE SIZE.
COORDINATE OVERHEAD RECEPTACLES WITH TELECOM EQUIPMENT RACK AND OVERHEAD LADDER RACK
PRIOR TO ROUGH-IN.
BRANCH CIRCUIT & CONTROL WIRING TO ASSOCIATED OUTDOOR UNIT. REFER TO ONELINE DIAGRAM FOR
CONDUIT & WIRE SIZE.
REFER TO LIGHTING CONTROL ONELINE DIAGRAM AND DETAILS FOR ADDITIONAL INFORMATION.
PROVIDE SEPARATE FIRE ALARM SUPERVISED 120V BRANCH CIRCUIT FOR SHUNT BREAKER CONTROL
POWER.
1. (F) AND/OR DASHED LINES INDICATE FUTURE EQUIPMENT, (N) AND/OR SOLID LINES INDICATE NEW EQUIPMENT
UNLESS NOTED OTHERWISE.
2. SEE FIRE ALARM MASTER LEGEND AND GENERAL NOTES.
3. ALL RECEPTACLES WITH WEATHER PROOF DESIGNATION SHALL BE PROVIDED WITH LOCKABLE METAL 'FLIP
STYLE' WEATHERPROOF COVER, HUBBELL #MX20508 OR EQUAL.
4. PIPING AND / OR DUCTWORK SHALL NOT BE ROUTED IN THE DEDICATED ELECTRICAL EQUIPMENT SPACE AT OR ABOVE ELECTRICAL SWITCHBOARDS, DISTRIBUTION BOARDS, PANELBOARDS, ETC. (PER 2005 NEC 110.26F).
PROVIDE DEPTH AND WIDTH OF WORKING SPACE FOR ELECTRICAL EQUIPMENT AS REQUIRED PER 2011 NEC
110.26. REFER TO DETAIL A/E005 FOR MORE INFORMATION.
5. THE CONTRACTOR SHALL OBTAIN ALL WIRING DIAGRAMS ASSOCIATED WITH MECHANICAL EQUIPMENT CONTROLS FROM MECHANICAL/CONTROLS CONTRACTOR. CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY CONTROLS CONTRACTOR. ANY CONDUIT REQUIRED FOR CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR AND SHALL BE COMPLETED UNDER THE SUPERVISION OF
MECHANICAL/CONTROLS CONTRACTOR.
6. LOCATE ALL DISCONNECTS, STARTERS AND DRIVES WHERE ACCESSIBLE. PROVIDE ACCESS AND CLEARANCE
AS REQUIRED PER NEC. PROVIDE ACCESS HATCH IF LOCATED ABOVE HARD LID CEILING.
7. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR MECHANICAL UNIT MODEL NUMBERS AND SPECIFIC
ELECTRICAL REQUIREMENTS, OPTIONS AND ACCESSORIES.
8. INFORMATION ON MECHANICAL DRAWINGS SUPERSEDE INFORMATION SHOWN ON ELECTRICAL DRAWINGS.
ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL DRAWINGS PRIOR TO ROUGH-IN.
9. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING ELECTRICAL REQUIREMENTS FOR FINAL MECHANICAL EQUIPMENT INSTALLED. SHOULD THERE BE ANY DISCREPANCY BETWEEN ACTUAL EQUIPMENT INSTALLED AND ELECTRICAL OR MECHANICAL DRAWINGS, CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY
FOR CLARIFICATION AND FURTHER DIRECTION.
10. REFER TO STATEMENT OF BID ALTERNATES, SHEET EE001 FOR AREA DESIGNATIONS AND ADDITIONAL
INFORMATION.
Revisions: Date:
VHARENCASSAC
Oval