Attachment 6 - EP101 POWER _ SIGNAL PLANS - LEVEL 1.pdf

PDF 286 KB Posted

Attached to
Y1MG--654-19-3-6360-0025, Construction, 654-19-914, Solar Panels New Parking Garage, (VA-19-00049803)
Solicitation number
36C77621R0077
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E 9- 35 84

A S- 12 16

E 9- 12 06

E 9-

A S-

E 9-

E 9-

A S-

E 9-

E 9-

A S-

E 9-

E 9-

A S-

E 9-

E9-3584

AS-1216

E9-1206 E9-1206

AS-1216

E9-1235

E 9-

A S-

E 9-

E 9-

A S-

E 9-

E 9-

A S-

E 9-

E9-1206

AS-1216

E9-1235

E9-1206

AS-1216

E9-1235

E 9- 12 06

A S- 12 16

E 9- 12 35

E9-1206

AS-1216

E9-1235

E9-3584

AS-1216

E9-1206

NN

N

J J

H

2 4 5 6 7 8 9 10 11 14

G

F

E

B

A

D

C

12 133

STAIR 01

ELEVATOR

ELEVATOR

MACHINE

ELECTRICAL

STORAGE

STAIR 02

EP401

B

EP401

A

SHUNT TRIP

STATION

WP

WP

TELECOM

AND

SECURITY

STORAGE

'PBLN1A'

'SE015'

ACO

ACO

SE015SE015

WP

WP

#10's

ACO

SE015

2 2

M

(F) PV METER

(F) PV DISC.

(F) PV PB-1

FAAP

WP

6 6

PVPB-3 5 7

'PBLELS1A'

PBLN1A -[2,N]G

DOOR OPERATOR, TYP

3/4" C.PBLN1A -[30,N]G

(SPLIT CKT)

WP

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

Architect / Civil Engineer:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Structural Engineers: E/T Engineers:

CARL WALKER INC.

8910 Purdue Rd.

Suite 400 Indianapolis, IN 46268

Tele: 317.735.3349 POC: Doug Gannon

PK ELECTRICAL, INC.

681 Sierra Rose Drive Suite B Reno, NV 89511

Tele: 775.826.9010 POC: Jason Aviles

M/P Engineers:

AINSWORTH ASSOCIATES

1420 Holcomb Avenue Suite 201 Reno, NV 89502

Tele: 775.329.9100 POC: Roger Gravelle

GUIDON DESIGN INC.

905 North Capitol Avenue Suite 100 Indianapolis, IN 46204

Tele: 317.800.6388 POC: Stacey Paul

B

IM

/1

V A

R e n o P a rk in g G a ra g e /1

V A

R e n o P a rk in g G a ra g e

V .r v t

/1

/2

:2

:3

A

M

EP101

POWER & SIGNAL PLANS - LEVEL 1 PARKING GARAGE DESIGN

RENO, NV

654-250

2018/03/05 JEG PKE

BID DOCUMENTS

NOT SPRINKLERED

C. Patrick Cassady, COR

EP101 Scale: 1/8" = 1'-0"

A POWER & SIGNAL PLANS - LEVEL 1

GENERAL NOTES

SHEET NOTES

1. (F) AND/OR DASHED LINES INDICATE FUTURE EQUIPMENT, (N) AND/OR SOLID LINES INDICATE NEW EQUIPMENT

UNLESS NOTED OTHERWISE.

2. SEE FIRE ALARM MASTER LEGEND AND GENERAL NOTES.

3. ALL RECEPTACLES WITH WEATHER PROOF DESIGNATION SHALL BE PROVIDED WITH LOCKABLE METAL 'FLIP

STYLE' WEATHERPROOF COVER, HUBBELL #MX20508 OR EQUAL.

4. PIPING AND / OR DUCTWORK SHALL NOT BE ROUTED IN THE DEDICATED ELECTRICAL EQUIPMENT SPACE AT OR ABOVE ELECTRICAL SWITCHBOARDS, DISTRIBUTION BOARDS, PANELBOARDS, ETC. (PER 2005 NEC 110.26F).

PROVIDE DEPTH AND WIDTH OF WORKING SPACE FOR ELECTRICAL EQUIPMENT AS REQUIRED PER 2011 NEC

110.26. REFER TO DETAIL A/E005 FOR MORE INFORMATION.

5. THE CONTRACTOR SHALL OBTAIN ALL WIRING DIAGRAMS ASSOCIATED WITH MECHANICAL EQUIPMENT CONTROLS FROM MECHANICAL/CONTROLS CONTRACTOR. CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY CONTROLS CONTRACTOR. ANY CONDUIT REQUIRED FOR CONTROL WIRING SHALL BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR AND SHALL BE COMPLETED UNDER THE SUPERVISION OF

MECHANICAL/CONTROLS CONTRACTOR.

6. LOCATE ALL DISCONNECTS, STARTERS AND DRIVES WHERE ACCESSIBLE. PROVIDE ACCESS AND CLEARANCE AS

REQUIRED PER NEC. PROVIDE ACCESS HATCH IF LOCATED ABOVE HARD LID CEILING.

7. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR MECHANICAL UNIT MODEL NUMBERS AND SPECIFIC

ELECTRICAL REQUIREMENTS, OPTIONS AND ACCESSORIES.

8. INFORMATION ON MECHANICAL DRAWINGS SUPERSEDE INFORMATION SHOWN ON ELECTRICAL DRAWINGS.

ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL DRAWINGS PRIOR TO ROUGH-IN.

9. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING ELECTRICAL REQUIREMENTS FOR FINAL MECHANICAL EQUIPMENT INSTALLED. SHOULD THERE BE ANY DISCREPANCY BETWEEN ACTUAL EQUIPMENT INSTALLED AND ELECTRICAL OR MECHANICAL DRAWINGS, CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY

FOR CLARIFICATION AND FURTHER DIRECTION.

10. ALL CEILING MOUNTED DEVICE CONDUITS SHALL BE SURFACE MOUNTED AND UTILIZE BEAM BLOCKOUTS FOR

CONDUIT ROUTING. REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION.

11. VERTICAL COLUMNS SHALL BE ACCEPTABLE FOR EMBEDDED RACEWAY UPON STRUCTURAL ENGINEER'S

APPROVAL OF SUBMITTED SHOP DRAWINGS.

12. REFER TO STATEMENT OF BID ALTERNATES, SHEET EE001 FOR AREA DESIGNATIONS AND ADDITIONAL

INFORMATION.

1 REFER TO ONELINE DIAGRAM FOR ADDITIONAL INFORMATION.

2 BRANCH CIRCUIT & CONTROL WIRING TO ASSOCIATED INDOOR UNIT. REFER TO ONELINE DIAGRAM FOR CONDUIT

& WIRE SIZE.

3 REMOTE SHUNT TRIP SWITCH SHALL BE LOCATED A MINIMUM OF 7' AFG AT APPROVED FIRE DEPARTMENT LOCATION. SHUNT TRIP SWITCH SHALL BE LOCATED WITH A 12" EQUILATERAL RED TRIANGLE.

4 CONDUIT STUB FOR FUTURE ROOF-MOUNTED PV SYSTEM. REFER TO ONELINE DIAGRAM FOR ADDITIONAL

INFORMATION.

5 PULL BOX FOR FUTURE ROOF-MOUNTED PV SYSTEM. REFER TO ONELINE DIAGRAM FOR ADDITONAL

INFORMATION.

6 PROVIDE 240V, 2P, 30A, NEMA 3R, NON-FUSED DISCONNECT SWITCH.

7 BID ALTERNATE. REFER TO A/EE001.

8 PROVIDE ELECTRICAL CONNECTIONS TO MOTORIZED DOOR OPERATOR (DOOR OPERATOR PROVIDED BY GENERAL CONTRACTOR). ELECTRICAL CONTRACTOR SHALL INSTALL ALL ASSOCIATED DEVICES, CONDUIT, CABLING, ETC. FOR A COMPLETE AND OPERABLE SYSTEM. COORDINATE WITH GENERAL CONTRACTOR AND

VENDOR PRIOR TO ROUGH-IN.

Revisions: Date:

VHARENCASSAC

Oval

VHARENCASSAC

Oval

File details come from the government source that posted it. Updated .