ATTACHMENT 7 - Drawings 6 of 13.pdf
PDF 19 MB Posted
- Solicitation number
- 36C77623B0005
About this file
This document provides details on a federal solicitation and related file. The solicitation number 36C77623B0005 is for the Construction of the EHRM Infrastructure Upgrades at the Cincinnati VAMC, Project #539-21-701, issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The opportunity type is a solicitation for construction services to upgrade infrastructure at the Cincinnati VA Medical Center. Attachment 7 appears to include drawings related to the project scope of work. No further information is provided on pricing, response dates, or other contractual requirements.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
COMP. RM. 134 - DEMO
MD-461-FT.64.1
CL / KW
ENLARGED FLOOR PLANS - FIRST
FLOOR
1. DEMOLISH DIFFUSERS BACK TO MAINS AND CAP.
WHERE LINETYPE INDICATES DEMOLITION; DEMOLISH THE MECHANICAL DUCTWORK, PIPING, AND EQUIPMENT AS INDICATED. DEMOLITION SHALL BE COMPLETE AND INCLUDE: CONTROLS, INSULATION, HANGERS, AND SUPPORTS.
1.
REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
2.
/2
8/
UP
DN
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
WORKOUT 220 - DEMO
MD-462-FT.64.2
CL / KW
ENLARGED FLOOR PLANS - SECOND
FLOOR
1. DEMOLISH THERMOSTAT AND RETAIN FOR INSTALLATION
AS SHOWN ON M-462-FT.64.2.
2. MEASURE AIRFLOW OF SUPPLY DIFFUSER ON THIS
SYSTEM PRIOR TO CONSTRUCTION. RE-BALANCE
EXISTING SUPPLY DIFFUSER IN ITS NEW LOCATION TO
MATCH THE PRE-CONSTRUCTION DIFFUSER AIRFLOW.
SEE M-462-FT.64.2 FOR RELOCATED DIFFUSER LOCATION.
WHERE LINETYPE INDICATES DEMOLITION; DEMOLISH THE MECHANICAL DUCTWORK, PIPING, AND EQUIPMENT AS INDICATED. DEMOLITION SHALL BE COMPLETE AND INCLUDE: CONTROLS, INSULATION, HANGERS, AND SUPPORTS.
1.
REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
2.
/2
8/
VAV
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
NURSES STATION 313 - DEMO
MD-463-FT.64.3
CL / KW
ENLARGED FLOOR PLANS - THIRD
FLOOR
1. DEMOLISH THERMOSTAT AND RETAIN FOR INSTALLATION
IN NEW OFFICE 313A AS SHOWN ON M-463-FT.64.3.
2. DEMO BACK TO MAIN AND CAP.
3. MEASURE AIRFLOW OF EXISTING DIFFUSER TO REMAIN
PRIOR TO CONSTRUCTION. ADJUST VAV AIRFLOW TO
CFM OF DIFFUSER TO REMAIN.
WHERE LINETYPE INDICATES DEMOLITION; DEMOLISH THE MECHANICAL DUCTWORK, PIPING, AND EQUIPMENT AS INDICATED. DEMOLITION SHALL BE COMPLETE AND INCLUDE: CONTROLS, INSULATION, HANGERS, AND SUPPORTS.
1.
REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
2.
/2
8/
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
BUILDING TB - DEMO
MD-480-C.TB.1
TB
CL / KW
ENLARGED FLOOR PLANS - FIRST
FLOOR
KEYED NOTES
1. DEMOLISH DIFFUSER BACK TO MAIN AND CAP AIR TIGHT.
2. DEMOLISH RETURN GRILLE AND DUCT BACK TO MAIN
AND CAP AIR TIGHT. SAVE RETURN GRILLE FOR
INSTALLATION AS SHOWN ON M-480-C.TB.1. MEASURE
RETURN GRILLE AIRFLOW PRIOR TO REMOVING TO
BALANCE THE GRILLE CORRECTLY ON THE NEW
INSTALLATION.
3. MEASURE AIRFLOWS OF ALL SUPPLY DIFFUSERS ON
THIS SYSTEM PRIOR TO CONSTRUCTION. EVENLY
RE-BALANCE EXISTING SUPPLY DIFFUSERS TO REMAIN
TO MATCH THE PRE-CONSTRUCTION TOTAL SYSTEM
AIRFLOW.
WHERE LINETYPE INDICATES DEMOLITION; DEMOLISH THE MECHANICAL DUCTWORK, PIPING, AND EQUIPMENT AS INDICATED. DEMOLITION SHALL BE COMPLETE AND INCLUDE: CONTROLS, INSULATION, HANGERS, AND SUPPORTS.
1.
REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
2.
/2
8/
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
CONFERENCE 105 - DEMO
MD-490-C.TE.1
TE
CL / KW
ENLARGED FLOOR PLANS - FIRST
FLOOR
1. DEMOLISH DIFFUSER AND DUCTWORK BACK TO MAIN
AND CAP AIR TIGHT.
2. MEASURE AIRFLOWS OF ALL SUPPLY DIFFUSERS ON
THIS SYSTEM PRIOR TO CONSTRUCTION. EVENLY
RE-BALANCE EXISTING SUPPLY DIFFUSERS TO REMAIN
TO MATCH THE PRE-CONSTRUCTION TOTAL SYSTEM
AIRFLOW.
WHERE LINETYPE INDICATES DEMOLITION; DEMOLISH THE MECHANICAL DUCTWORK, PIPING, AND EQUIPMENT AS INDICATED. DEMOLITION SHALL BE COMPLETE AND INCLUDE: CONTROLS, INSULATION, HANGERS, AND SUPPORTS.
1.
REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
2.
/2
8/
X8
X1
X8
X8
32X1426X12
X8
8" RS
1'' CCD
1'' CCD
2'' RL
8" RS
2" RL
2" RL UP
1 18" RS UP
2" RL UP
1 18" RS UP
24x22
24x22
MD
MD
1" CCD 1" CCD
8" RS UP
8" RL UP
8" RL
8" RS
1" CCD UP
EX CD
1" CCD
8" RL UP
8" RS UP
8" RS
8" RL
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELE. EQUIP. RM. A035 - NEW
M-401-C.1.B
CL / KW
ENLARGED FLOOR PLANS -
BASEMENT
Scale: 1/4" = 1'
TELE. ROOM B021 - NEW
Scale: 1/4" = 1'
ELECTRIC CLOSET A0005 - NEW
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
1. AHU-038 COOLING COIL CONDENSATE.
2. ROUTE CONDENSATE DOWN TO JANITOR'S SINK.
3. ROUTE REFRIGERANT PIPING UP THROUGH FIRST
FLOOR. SEE M-403-C.1.2 FOR CONTINUATION.
4. TIE CONDENSATE INTO EXISTING PUMP AND
CONDENSATE PIPING.
5. ALL SUPPLY DUCT IN A035 SHALL BE INTERNALLY LINED
WITH 1/2" FLEXIBLE ELASTOMERIC INSULATION.
6. ROUTE REFRIGERANT PIPING FROM AIR HANDLING UNIT
UP THROUGH THIRD FLOOR TO CONDENSING UNIT. SEE
M-404-C.1.3 FOR CONTINUATION. ROUTE REFRIGERANT IN
LOCATION OF THE EXISTING REFRIGERANT PIPING THAT
IS SHOWN TO BE DEMOLISHED ON MD-401-C.1.B.
7. TIE EXISTING THERMOSTATS INTO NEW AIR HANDLING
UNITS.
8. ROUTE REFRIGERANT PIPING UP TO FIRST FLOOR. SEE
M-402-C.1.1 FOR CONTINUATION.
9. ENSURE EXISTING AHU-035B IS IN OPERATION AND
EXISTING AHU-035A IS OFF. CLOSE THE MANUAL DAMPER
ON AHU-035A DUCTWORK AND DEMOLISH DUCTWORK AS
NECESSARY BETWEEN AHU-035A AND THE DAMPER.
AHU-035A TO HAVE A TEMPORARY DUCT SETUP TO
BLOW CONDITIONED AIR AROUND THE PLAN SOUTH END
OF THE WALL DIVIDING A035. ONCE TEMPORARY
DUCTWORK IS IN PLACE, AHU-035A SHALL BE IN
OPERATION AND AHU-035B SHALL BE TURNED OFF.
DEMOLISH AHU-035B, ASSOCIATED CONDENSING UNIT,
REFRIGERANT PIPING, AND CONDENSATE PIPING AS
SHOWN. DEMOLISH THE REMAINING EXISTING
DUCTWORK AS SHOWN ON THE PLANS AND NOT
RELATED TO AHU-035B OPERATION. ONCE THE
DEMOLITION OF THESE ITEMS IS COMPLETE, NEW
EQUIPMENT INSTALLATION CAN BEGIN. INSTALL ACU-23,
CU-14, ASSOCIATED REFRIGERANT PIPING AND
CONDENSATE PIPING. INSTALL ALL NEW DUCTWORK PER
THE PLANS. INSTALL DUCTWORK FOR ACU-24 BUT STOP
AFTER THE INSTALLATION OF THE MOTORIZED DAMPER
TO ALLOW FOR THE INSTALLATION OF ACU-24. ENSURE
THE DAMPER FOR ACU-24 IS CLOSED AND THE DAMPER
FOR ACU-23 IS OPEN. ACU-23 AND CU-14 CAN BE
STARTED UP TO PROVIDE COOLING FOR A035. EXISTING
AHU-035A CAN BE TURNED OFF. DEMOLISH AHU-035A,
ASSOCIATED CONDENSING UNIT, ASSOCIATED
REFRRIGERANT PIPING, AND CONDENSATE PIPING.
INSTALL NEW EQUIPMENT AND DUCT AS SHOWN ON THE
PLANS. ONCE INSTALLATION IS COMPLETE, ACU-23 AND
ACU-24 TO OPERATE AS SHOWN ON M600. SEE
MD-401-C.1.B FOR DEMOLITION SCOPE OF WORK
DRAWING FOR A035.
1-ACU 1
1-ACU 2
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
1-ACU 23
1-ACU 24
S-1
S-1
S-1
S-1
S-1
/2
8/
1" CCD
1" CCD DN
8" RL
8" RS UP
8" RS
8" RL
8" RS
8" RL
4" RS
8" RL UP
8" RS UP
8" RL UP
8" RL
4" RS
1" CCD
1" CCD DN
8" RL
8" RS
8" RS DN
8" RL DN
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM A134A - NEW
M-402-C.1.1
CL / KW
ENLARGED FLOOR PLANS - FIRST
FLOOR
Scale: 1/4" = 1'
TELECOM ROOM A144A - NEW
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
1. INSTALL DEMOLISHED RETURN GRILLE AS SHOWN ON
MD-402-C.1.1. CONNECT FLEXIBLE RETURN DUCT TO
RETURN GRILLE.
2. INSTALL DEMOLISHED SUPPLY DIFFUSER AS SHOWN ON
MD-402-C.1.1. CONNECT SUPPLY DUCT TO SUPPLY
DIFFUSER.
3. INSTALL CATCH PANS. SEE DETAIL 1 ON SHEET M-500.
PROVIDE WITH SMALL CONDENSATE PUMP SIMILAR TO
WHAT IS PROVIDED WITH ACU EQUIPMENT.
4. ROUTE CONDENSATE DOWN TO JANITOR'S SINK.
5. ROUTE REFRIGERANT PIPING UP TO SECOND FLOOR.
SEE M-403-C.1.2 FOR CONTINUATION.
6. ROUTE REFRIGERANT ALONG ROOF AND RISE UP IN THE
CORNER OF THE BUILDING TIGHT TO WALL TO REMAIN
CLEAR OF THE CANTEEN WINDOW AS MUCH AS
POSSIBLE. REFRIGERANT PIPING TO ENTER CEILING
AREA OF THE CANTEEN.
1-ACU 4
1-ACU 6
1-ACU 5
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
1-CU 3
1-CU 2
/2
8/
1" CCD
EX 1" CCD DN
8" RL
8" RS
8" RS
8" RL
1" CCD
EX 1" CCD DN
8" RS UP
8" RL UP
8" RL UP/DN
8" RS UP/DN
8" RL
8" RS
EXISTING
REFRIGERANT
PIPING
VAV 1" CCD
1" CCD
1" CCD DN
8" RL UP
8'' RS UP
8" RL
8" RS
8" RL
8" RS
8" RS DN
8" RL DN
8" RS UP
8" RL UP
8" RS DN 5
8" RS UP
8" RL DN 3
8" RL UP
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM A2006A - NEW
M-403-C.1.2
CL / KW
ENLARGED FLOOR PLANS - SECOND
FLOOR
Scale: 1/4" = 1'
TELECOM ROOM B232 - NEW
Scale: 1/4" = 1'
TELECOM ROOM C236A - NEW
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
1. INSTALL CATCH PANS. SEE DETAIL 1 ON SHEET M-500.
PROVIDE WITH SMALL CONDENSATE PUMP SIMILAR TO
WHAT IS PROVIDED WITH ACU EQUIPMENT.
2. INSTALL MITERED ELBOW TO EXISTING RETURN AIR
DUCT AND ROUTE NEW DUCT TO NEW RETURN GRILLE
LOCATION. NEW RETURN DUCT SIZE, TYPE AND
PRESSURE CLASS TO MATCH EXISTING DUCTWORK.
INSULATE USING 1.5" THICK FIBERGLASS BLANKET
INSULATION, 1.5 LB DENSITY.
3. INSTALL RETURN GRILLE SAVED FROM DEMOLITION,
SEE MD-403-C.1.2 FOR REFERENCE.
4. ROUTE CONDENSATE DOWN TO JANITOR'S SINK.
5. ROUTE REFRIGERANT PIPING UP THROUGH THIRD
FLOOR. SEE M-405-C.1.4 FOR CONTINUATION.
6. ROUTE REFRIGERANT PIPING DOWN THROUGH FIRST
FLOOR. SEE M-401-C.1.B FOR CONTINUATION. ROUTE
REFRIGERANT PIPING UP TO THIRD FLOOR. SEE
M-404-C.1.3 FOR CONTINUATION.
7. RE-BALANCE DIFFUSER TO AIRFLOW PRIOR TO
CONSTRUCTION. BALANCE VAV TO MATCH (2) SUPPLY
DIFFUSER TOTALS FOR CONFERENCE ROOM. IF VAV
MINIMUM AIRFLOW IS HIGHER THAN TOTAL DIFFUSER
AIRFLOW FOR THAT VAV, INCREASE THE DIFFUSER
AIRFLOWS EVENLY TO MEET THE MINIMUM VAV
AIRFLOW CFM.
8. RE-BALANCE DIFFUSER TO AIRFLOW PRIOR TO
CONSTRUCTION. BALANCE VAV TO MATCH SUPPLY
DIFFUSER TOTAL. IF VAV MINIMUM AIRFLOW IS HIGHER
THAN TOTAL DIFFUSER AIRFLOW FOR THAT VAV,
INCREASE THE DIFFUSER AIRFLOWS EVENLY TO MEET
THE MINIMUM VAV AIRFLOW CFM.
9. BALANCE RETURN GRILLE CFM TO MATCH SUPPLY
DIFFUSER CFM.
1-ACU 7
1-ACU 9
1-ACU 11
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
8X 8 R
A
1-CU 5
Scale: 1/4" = 1'
A/C SHAFT REFFRIGERANT PIPING - NEW
7 7
/2
8/
EX 1" CCD DN
S-1
VAV
EX
EX
EX
EX
R-1
EX
8" DIA
DN
UP
VAV
1" CCD EX 1" CCD UP/DN
8" RL
8" RS
8" RL UP
8" RS UP
VAV
1" CCD
1" CCD
1" CCD
1" CCD
8" RL UP
8" RS UP
1" CCD
T
MECHANICAL
A3002
8" RL DN
8" RS DN
8'' RL
8'' RS
8'' RL DN
8'' RS DN
4" RS
8" RL
PIPE SUPPORT
PIPE SUPPORT
8" RS
2" RL
2" RL
8'' RS
2" RL
1 18" RS
2" RL
1 18" RS
1" CCD
4" RS UP
8" RL UP
4" RS UP / DN
8" RL UP / DN
8 " RS
8" RL
8 " RS
8" RL
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM B312D - NEW
M-404-C.1.3
CL / KW
ENLARGED FLOOR PLANS - THIRD
FLOOR
Scale: 1/4" = 1'
FAMILY WAITING C310 AND SLEEPING ROOM 383A - NEW
Scale: 1/4" = 1'
TELECOM ROOM C3006 - NEW
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
1-ACU 13
1-ACU 14
1-ACU 16
1. INSTALL CATCH PANS. SEE DETAIL 1 ON SHEET M-500.
COLLECT CATCH PAN AND ACU CONDENSATE BEFORE
CONNECTING TO CONDENSATE PUMP.
2. ROUTE CONDENSATE DOWN TO JANITOR'S SINK.
3. ROUTE REFRIGERANT PIPE ALONG ROOF. ROUTE
PIPING UP ALONG MECHANICAL ROOM WALL AND
ENTER THE MECHANICAL ROOM AT A SIMILAR
ELEVATION TO THE EXISTING REFRIGERANT PIPING.
4. ROUTE REFRIGERANT PIPING DOWN TO SECOND
FLOOR. SEE M-403-C.1.2 FOR CONTINUATION.
5. ROUTE REFRIGERANT PIPING UP TO FOURTH FLOOR.
SEE M-405-C.1.4 FOR CONTINUATION.
6. INSTALL NEW CONDENSING UNIT. ROUTE
REFRIGERANT PIPING FROM CONDENSING UNIT ON
THIRD FLOOR TO AIR HANDING UNIT IN TR A035
BASEMENT. SEE M-401-C.1.B FOR CONTINUATION.
7. SEE M-500 FOR PIPE SUPPORT DETAIL.
8. RE-BALANCE DIFFUSER TO AIRFLOW PRIOR TO
CONSTRUCTION. BALANCE VAV TO MATCH SUPPLY
DIFFUSER TOTAL. IF VAV MINIMUM AIRFLOW IS HIGHER
THAN TOTAL DIFFUSER AIRFLOW FOR THAT VAV,
INCREASE THE DIFFUSER AIRFLOWS EVENLY TO MEET
THE MINIMUM VAV AIRFLOW CFM.
9. RE-INSTALL RETAINED SUPPLY DIFFUSER. SEE
MD-404.C.1.3.
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
1 1
Scale: 1/4" = 1'
MECHANICAL A3002 - NEW
1-CU 11-CU 6
Scale: 1/4" = 1'
SECOND FLOOR ROOF - NEW
1-CU 14 1-CU 15
Scale: 1/4" = 1'
TELECOM ROOM C305 - NEW
SEE DETAIL #2, THIS SHEET,
FOR CONTINUATION
SEE DETAIL #5, THIS SHEET,
FOR CONTINUATION
1-ACU 15
/2
8/
/2
8/
8" RL DN / UP TO EIGHTH FLOOR
8" RS DN / UP TO EIGHTH FLOOR
8" RL DN
8" RS DN
1" CCD DN
8" RS
8" RL
1" CCD
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM A540 - NEW
M-406-C.1.5
CL / KW
ENLARGED FLOOR PLANS - FIFTH
FLOOR
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
1. INSTALL CATCH PANS. SEE DETAIL 1 ON SHEET M-500.
PROVIDE WITH SMALL CONDENSATE PUMP SIMILAR TO
WHAT IS PROVIDED WITH ACU EQUIPMENT.
2. ROUTE REFRIGERANT PIPING UP TO EIGHTH FLOOR.
SEE M-409-C.1.8 FOR CONTINUATION.
3. ROUTE REFRIGERANT PIPING DOWN TO FOURTH
FLOOR. SEE M-405-C.1.4 FOR CONTINUATION.
4. ROUTE CONDENSATE PIPING DOWN TO FOURTH
FLOOR. SEE M-405-C.1.4 FOR CONTINUATION.
5. ROUTE PIPING AROUND EXISTING AIR DUCT.
1-ACU 18
/2
8/
DN UP
EX 1" CCD UP/DN
8" RS DN
8" RL DN
8" RS
8" RL
8" RL
8" RS
8" RL UP / DN
8" RS UP / DN
1" CCD UP
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM A643 - NEW
M-407-C.1.6
CL / KW
ENLARGED FLOOR PLANS - SIXTH
FLOOR
1-ACU 19
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
1. ROUTE REFRIGERANT PIPING DOWN TO FIFTH FLOOR.
SEE M-106-C.1.5 FOR CONTINUATION.
/2
8/
A/C Shaft
8" RL DN TO FOURTH FLOOR
8" RS DN TO FOURTH FLOOR
8" RS
8" RL
1" CCD DN
FCU2-3
CUH CUH
8"Ø
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM A732 - NEW
M-408-C.1.7
CL / KW
ENLARGED FLOOR PLAN - SEVENTH
FLOOR
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
1. INSTALL CATCH PANS. SEE DETAIL 1 ON SHEET M-500.
PROVIDE WITH SMALL CONDENSATE PUMP SIMILAR TO
WHAT IS PROVIDED WITH ACU EQUIPMENT.
2. ROUTE REFRIGERANT PIPING DOWN TO FOURTH FLOOR.
SEE M-404-C.1.3 FOR CONTINUATION.
3. MEASURE DIFFUSER AIRFLOWS PRIOR TO
CONSTRUCTION. RE-BALANCE DIFFUSER TO MATCH
PRE-CONSTRUCTION AIRFLOW. RE-BALANCE VAV TO
MATCH TOTAL AIRFLOW FROM THE (3) DIFFUSERS.
4. INSTALL SUPPLY DIFFUSER FROM MD-408-C.1.7.
CONNECT SUPPLY DUCT FROM MAIN TO SUPPLY
DIFFUSER.
5. INSTALL EXHAUST GRILLES FROM MD-408-C.1.7.
CONNECT EXHAUST DUCT FROM MAIN TO EXHAUST
GRILLES.
6. INSTALL THERMOSTAT FROM MD-408-C.1.7.
7. CONTRACTOR TO MEASURE EXISTING DIFFUSER AND
GRILLE AIRFLOWS PRIOR TO CONSTRUCTION.
8. S-2 IN ROOM 704A TO BE BALANCED TO 1/3 OF THE
PRE-CONSTRUCTION AIRFLOW OF THE EXISTING
SUPPLY DIFFUSER. THE EXISTING SUPPLY DIFFUSER IN
ROOM 704 TO BE BALANCED TO 2/3 OF THE
PRE-CONSTRUCTION AIRFLOW.
9. CABINET UNIT HEATER IS EXISTING TO REMAIN.
10. INSTALL EXISTING THERMOSTAT IN NEW LOCATION. SEE
MD-408-C.1.7 FOR DETAILS ON REMAINING THERMOSTAT.
Scale: 1/4" = 1'
SOUTH SEVENTH FLOOR REWORK - NEW
1-ACU 20
5 5
S-2
9 9
/2
8/
DN UP
Stor.
A846A
Stor.
A846B
B802A
Dermatology
A838
Conf.
A839
Stor.
A841
HAC
A842
Stor.
A840
Corridor
C*8*1
Stair 1
S*8*1
A/C Shaft
8" RL DN TO FIFTH FLOOR
8" RS DN TO FIFTH FLOOR
8" RS
8" RL
1" CCD
1" CCD
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM A838 - NEW
M-409-C.1.8
CL / KW
ENLARGED FLOOR PLAN - EIGHTH
FLOOR
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
1. ROUTE CONDENSATE DOWN TO JANITOR'S SINK.
2. INSTALL CATCH PANS. SEE DETAIL 1 ON SHEET M-500.
PROVIDE WITH SMALL CONDENSATE PUMP SIMILAR TO
WHAT IS PROVIDED WITH ACU EQUIPMENT.
3. ROUTE REFRIGERANT PIPING DOWN THROUGH THIRD
FLOOR. SEE M-403-C.1.2 FOR CONTINUATION.
4. ROUTE REFRIGERANT PIPING DOWN INTO TR C311A
BELOW THROUGH EXISTING ABANDONED ROOF CURB.
5. ROUTE REFRIGERANT PIPING UP TO FIFTH FLOOR. SEE
M-106-C.1.5 FOR CONTINUATION.
6. DOWN TO C3006. SEE M-404-C.1.3 FOR CONTINUATION.
7. ROUTE REFRIGERANT PIPING BELOW EXHAUST
DUCTWORK.
8. 1-CU-7 AND REFRIGERANT PIPING TO BE LOCATED
NORTH OF THE LADDER TO THE PENTHOUSE ROOF SO
AS TO NOT IMPEDE ON IT'S USE.
1-ACU 21
/2
8/
1" CCD DN
8" RL UP
8" RS UP
8" RL
8" RS
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM A916A - NEW
M-410-C.1.9
CL / KW
ENLARGED FLOOR PLANS - NINTH
FLOOR
1-ACU 22
1. ROUTE CONDENSATE DOWN TO JANITOR'S SINK.
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
/2
8/
8" RL
8" RS
8" RS UP
8" RL UP
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM 0001 - NEW
M-420-C.2.B
CL / KW
ENLARGED FLOOR PLANS -
BASEMENT
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
2-ACU 1
1. INSTALL CATCH PANS. SEE DETAIL 1 ON SHEET M-500.
2. TIE CATCH PAN DRAIN INTO SUCTION SIDE OF
CONDENSATE PUMP FOR 2-ACU 1.
3. ROUTE CONDENSATE DOWN TO JANITOR'S SINK.
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
/2
8/
STORAGE
LAUNDRY
CLEAN
UTILITY
KITCHEN &
PANTRY
LOUNGE
NURSES'
STATION
WORK
ROOM
CHARTING
CORRIDOR
NURSING
HOME
RECEPTION
V. MEN
V. WOMEN
BATHING
SUITE
Omnicells
8" RS UP/DN
8" RL UP/DN
8" RL UP
8" RS UP
8" RS
8" RL
1" CCD
1" CCD
10'' DIA SA
6" DIA SA
FLEX DUCT
EXISTING
STORM PIPING
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM 1040A - NEW
M-421-C.2.1
CL / KW
ENLARGED FLOOR PLANS - FIRST
LEVEL
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
1. INSTALL CATCH PANS. SEE DETAIL 1 ON SHEET M-500.
2. INSTALL EXISTING THERMOSTAT THAT WAS
PREVIOUSLY DEMOLISHED ON MD-421-C.2.1. EXTEND
WIRING AS REQUIRED TO REACH NEW INSTALLATION
LOCATION.
3. TIE CATCH PAN DRAIN INTO SUCTION SIDE OF
CONDENSATE PUMP FOR 2-ACU 2.
4. ROUTE CONDENSATE DOWN TO DRAIN FOR LAUNDRY.
5. INSTALL DIFFUSER THAT IS SHOWN AS DEMO ON
MD-421-C.2.1. INSTALL NEW 10" DIA DUCT AND TIE IN
EXISTING 8" DIA DUCT FOR SLOT DIFFUSER NEAR
WINDOW.
6. MEASURE DIFFUSER AIRFLOWS PRIOR TO
CONSTRUCTION. RE-BALANCE DIFFUSER TO MATCH
PRE-CONSTRUCTION AIRFLOW. RE-BALANCE VAV TO
MATCH TOTAL AIRFLOW FROM THE (3) DIFFUSERS.
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
6 6
/2
8/
8" RS
8" RL
VAV-4-5
8" RS DN
8" RL DN
8" RL DN
8" RS DN
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
M-422-C.2.2
CL / KW
ENLARGED FLOOR PLANS - SECOND
LEVEL
1. ROUTE CONDENSATE DOWN TO DRAIN FOR LAUNDRY.
CONDENSATE DRAIN TO BE AN INDIRECT CONNECTION.
2. LOCATE CU ON ROOF ABOVE.
3. ROUTE REFRIGERANT PIPING ALONG ROOF. DROP
DOWN INTO SPACE AS SHOWN.
4. ROUTE REFRIGERANT PIPING ALONG ROOF. DROP
DOWN INTO CHASE AS SHOWN.
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
2-ACU 3
Scale: 1/4" = 1'
TELECOM ROOM 204 - NEW
Scale: 1/4" = 1'
SECOND FLOOR ROOF - NEW
2-CU 3
2-CU 2
2-CU 1
/2
8/
8" RS UP 3
8" RL UP
8" RS
8" RL
8" RS
8" RL
1" CCD
1" CCD
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM 13A - NEW
M-430-C.3.B
CL / KW
ENLARGED FLOOR PLANS -
BASEMENT
1. INSTALL CATCH PANS. SEE DETAIL 1 ON SHEET M-500.
ONLY INSTALL PAN BELOW PIPING THAT IS LOCATED IN
NEW TR SPACE. CONNECT CONDENSATE PIPING ON
THE SUCTION SIDE OF THE CONDENSATE PUMP FOR
THE ACU.
2. INSTALL DIFFUSER THAT WAS SHOWN AS DEMO ON
MD-430-C.3.B. CONNECT FLEX DUCT TO
DIFFUSER.MEASURE DIFFUSER AIRFLOW PRIOR TO
CONSTRUCTION. BALANCE DIFFUSER TO
PRE-CONSTRUCTION AIRFLOW.
3. INSTALL GRILLE THAT WAS SHOWN AS DEMO ON
MD-430-C.3.B.
4. ROUTE CONDENSATE TO NEAREST FLOOR DRAIN IN
MECHANICAL ROOM 13.
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
3-ACU 1
/2
8/
UP
1" CCD DN
1" CCD
8" RL
8" RS
8" RL
8" RS
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM 205 - NEW
M-440-C.8.2
CL / KW
ENLARGED FLOOR PLANS - SECOND
FLOOR
1. ROUTE CONDENSATE TO STORAGE ROOM AND ROUTE
CONDENSATE TO DRAIN SERVING EXISTING AIR
HANDLER IN THIS ROOM.
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
8-ACU 1
8-CU 1
/2
8/
8" RL UP
8" RS UP
8" RL
8" RS
VAV
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM 101 - NEW
M-450-C.15.1
CL / KW
ENLARGED FLOOR PLANS - FIRST
FLOOR
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
1. ROUTE CONDENSATE DRAIN PIPING DOWN THROUGH
FLOOR TO NEAREST FLOOR DRAIN IN BASEMENT
MECHANICAL ROOM B15. DO NOT ROUTE CONDENSATE
DOWN INTO ELEVATOR EQUIPMENT ROOM.
2. ROUTE REFRIGERANT UP TO ROOF. SEE M-151-C.15.2.
3. MEASURE AIRFLOW OF EXISTING DIFFUSER TO REMAIN
PRIOR TO CONSTRUCTION. ADJUST VAV AIRFLOW TO
CFM OF DIFFUSER TO REMAIN. IF VAV MINIMUM
AIRFLOW IS HIGHER THAN TOTAL DIFFUSER AIRFLOW
FOR THAT VAV, INCREASE THE DIFFUSER AIRFLOWS
EVENLY TO MEET THE MINIMUM VAV AIRFLOW CFM.
15-ACU 1
/2
8/
1" CCD UP
1" CCD
8" RL UP/DN
8" RS UP/DN
8" RL UP
8" RS UP
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
COMP. RM. 134 - NEW
M-461-FT.64.1
CL / KW
ENLARGED FLOOR PLANS - FIRST
FLOOR
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
64-ACU 2
1. INSTALL CATCH PAN. SEE DETAIL 1 ON M-500 FOR
DETAIL.
2. ROUTE REFRIGERANT PIPING GOING UP AND DOWN IN
A COMPACT ARRANGEMENT TO KEEP PIPING OUT OF
THE WAY OF OTHER TRADES AS MUCH AS POSSIBLE.
/2
8/
8" RL DN
TYP. 2
1" CCD UP/DN
1" CCD
1" CCD
8" RS DN
TYP. 2
8" RL UP
8" RS UP
8" RL UP
TYP. 2
8" RS UP
TYP. 2
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.918.1766
GENERAL NOTES
KEYED NOTES
Scale: 1/4" = 1'
TELECOM ROOM 220 - NEW
M-462-FT.64.2
CL / KW
ENLARGED FLOOR PLANS - SECOND
FLOOR
1. INSTALL CATCH PANS. SEE DETAIL 1 ON SHEET M-500.
2. ROUTE REFRIGERANT PIPING GOING UP AND DOWN IN
A COMPACT ARRANGEMENT TO KEEP PIPING OUT OF
THE WAY OF OTHER TRADES AS MUCH AS POSSIBLE.
3. RELOCATE DIFFUSER THAT WAS NOTED TO BE
RETAINED IN MD-462-FT.64.2. RE-BALANCE EXISTING
SUPPLY DIFFUSER IN ITS NEW LOCATION TO MATCH
THE PRE-CONSTRUCTION DIFFUSER AIRFLOW.
4. INSTALL EXISTING THERMOSTAT IN NEW LOCATION.
SEE MD-462-FT.64.2 FOR DETAILS ON REMAINING
THERMOSTAT. 1
ALL EXISTING PIPING TO REMAIN IN A NEW TELECOM ROOM SHALL HAVE A CATCH PAN BELOW THE ENTIRE LENGTH OF
PIPE PER DETAIL 1 ON SHEET M-500.
1.
2. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD COORDINATE WITH STRUCTURAL. PROVIDE A
SEAL AROUND NEW PENETRATION.
3. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE TOP OF DOOR FRAME. COORDINATE FINAL ACU INSTALLATION
HEIGHTS WITH OTHER TRADES.
4. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK, OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS
BEFORE REMOVAL. SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5. REFRIGERANT LINE SIZES AND LENGTHS TO BE CONFIRMED BY THE CONTRACTOR FOR ACTUAL EQUIPMENT BEING
PROVIDED.
6. CONTRACTOR TO COORDINATE LOCATION AND MOUNTING OF MAG LOCK AND DOOR SECURITY PANEL WITH THE
MECHANICAL EQUIPMENT IN THE SPACE.
7. WHERE CONDENSATE PIPING TERMINATES, THE PIPING IS TO BE AIR-GAPPED TO DRAIN.
64-ACU 3
2 2
/2
8/
1" CCD DN
8" RL UP
TYP. 4
8" RS UP
TYP. 4
8" RS
8" RL
8" RS DN
TYP. 3
8" RL DN
TYP. 3
VAV
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
539-21-701
04-MAY-2022
100% CONSTRUCTION
DOCUMENTS
CINCINNATI VAMC EHRM
INFRASTRUCTURE UPGRADES
3200 VINE ST., CINCINNATI, OH
6 SOUTH OLD ORCHARD
WEBSTER GROVES, MO. 63119
T: 314.918.8383
F: 314.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .