ATTACHMENT 10 - Drawings 9 of 13.pdf

PDF 18 MB Posted

Attached to
36C77623B0005 EHRM Infrastructure Upgrades - Cincinnati Project #539-21-701
Solicitation number
36C77623B0005
Issued by

About this file

This document provides details on a federal solicitation and related file attachment. The solicitation number is 36C77623B0005 for the EHRM Infrastructure Upgrades - Cincinnati Project #539-21-701 opportunity with the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation is for construction services to upgrade the infrastructure at the Cincinnati VAMC. Attachment 10 contains drawings related to the project. The response is due by an unspecified date, and the award date was not included. The document provides relevant information on the federal agency, project name and number, opportunity type, and services required without unnecessary legal language or clauses.

View the file

Other files

File Type Posted
36C77623B0005 0004 - Extension 3-10-23.pdf PDF
Technical Questions and Answers - Cincinnati EHRM.pdf PDF
36C77623B0005 0003.pdf PDF
36C77623B0005 0002 - EHRM Infrastructure Upgrades - Cincinnati.pdf PDF
Site Visit Sign-In Sheet - 36C77632B0005 EHRM Infrastructure Construction - Cincinnati VAMC.pdf PDF
ATTACHMENT 24 - Construction Wage Rates - Hamilton 01-13-2023.pdf PDF
36C77623B0005 0001 - EHRM Infrastructure Upgrades - Cincinnati.pdf PDF
Site Visit Memorandum.pdf PDF
ATTACHMENT 4 - Drawings 3 of 13.pdf PDF
ATTACHMENT 23 - Contractor Safety - Environmental Form.pdf PDF
ATTACHMENT 6 - Drawings 5 of 13.pdf PDF
ATTACHMENT 18 - Technology Narrative.pdf PDF
ATTACHMENT 13 - Drawings 12 of 13.pdf PDF
ATTACHMENT 15 - Plumbing Narrative.pdf PDF
ATTACHMENT 19 - Hazardous Materials Inspection Report.pdf PDF
ATTACHMENT 24 - Construction Wage Rates - Hamilton 1-13-2022.pdf PDF
ATTACHMENT 21 - COVID-19 Safety Protocols 12-14-21.pdf PDF
ATTACHMENT 14 - Drawings 13 of 13.pdf PDF
ATTACHMENT 20 - Brand Name Justification.pdf PDF
ATTACHMENT 22 - Limitations on Subcontracting - Nov 2022.pdf PDF
ATTACHMENT 9 - Drawings 8 of 13.pdf PDF
ATTACHMENT 16 - Mechanical Narrative.pdf PDF
ATTACHMENT 7 - Drawings 6 of 13.pdf PDF
ATTACHMENT 3 - Drawings 2 of 13.pdf PDF
ATTACHMENT 17 - Electrical Narrative.pdf PDF
ATTACHMENT 2 - Drawings 1 of 13.pdf PDF
ATTACHMENT 25 - Site Visit Instructions.pdf PDF
ATTACHMENT 8 - Drawings 7 of 13.pdf PDF
ATTACHMENT 11 - Drawings 10 of 13.pdf PDF
ATTACHMENT 12 - Drawings 11 of 13.pdf PDF
ATTACHMENT 5 - Drawings 4 of 13.pdf PDF
36C77623B0005 Solicitation - Cincinnati EHRM.pdf PDF
ATTACHMENT 1 - Specifications.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Infusion A449

Stair 5 S*4*5

Sub. Lab.

A453 Pharm.

A454

Exam A455

Elec.

A456

Stor.

A457A

S.B.

A457B

Tlt.

A457C

D.B.

A457D

Proc.

A457E

Nurse

Station A457F

Lab.

A457G

Exam A458

Exam A458A

Exam A458B

Exam A458C

Elec.

A459

Stor.

A460

Soil. Util.

A461

CL. Lin.

A462

Exam A463

Exam 2 A464

Exam 4 A465

Exam 6 A466

Exam 8 A467

Exam 10 A468

Exam 9 A469

Exam 7 A470

Exam 5 A471

Exam 3 A472

Exam 1 A473

Exam A474

KIT.

A475

Supp.

A476

HAC

A477

GCRC

Corridor A457

Tlt.

A457H

Tlt.

A474A

Tlt.

A464A

Tlt.

A473A

Tlt.

A465A

Tlt.

A471A

Tlt.

A467A

Tlt.

A470A

Tlt.

A463A

DNUP

4 3

3 3

3 3

3 3

LOW VOLTAGE/ IT

Ross & Baruzzini Inc.

1600 Riveredge Parkway NW Suite 900 Atlanta, GA 30328

Project Number

Building Number

Drawing Number

Drawn By:Checked By:Issue Date:

Location

Project TitlePhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANT

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

100% CONSTRUCTION

DOCUMENTS

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

Scale:

FULLY SPRINKLERED

1/8" = 1'-0"

TD-153-C.1.4

TECHNOLOGY DEMOLITION FOURTH

FLOOR PARTIAL PLAN - D

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST. CINCINNATI, OH. 45220

539-21-701

TL

04-MAY-2022

PR

C1

1/8" = 1'-0"

TECHNOLOGY DEMOLITION FOURTH FLOOR PARTIAL PLAN - D

D B

A

GENERAL NOTES:

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS OTHERWISE NOTED.

3. EXISTING TELECOMMUNICATIONS ROOM OR IT CLOSET. CONTRACTOR SHALL DEMO

ALL PATCH PANELS AND CABLING RELATED TO THIS PROJECT. CONTRACTOR SHALL

REMOVE ALL DATA CABLES FROM THE DEVICE TO THE SOURCE. CONTRACTOR SHALL

COORDINATE WITH THE COR PRIOR TO BEGINNING WORK IN EACH TELECOM ROOM

(TR) OR IT CLOSET.

4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT, ELECTRICAL CABLES AND

EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT DATA RELATED. COORDINATE

WITH COR PRIOR TO REMOVING CABLING FROM WALL FIELDS OR FROM WALL

MOUNTED EQUIPMENT.

5. BUILDING AUTOMATION SYSTEMS (BAS), PACS, AND ELECTRONIC SECURITY SYSTEMS

CABLES SHALL NOT BE REMOVED. COORDINATE WITH COR TO IDENTIFY BAS, PACS,

OR SECURITY CABLES.

6. EXISTING TELECOMMUNICATIONS OUTLET. CONTRACTOR SHALL REMOVE ALL DEVICE

FACEPLATES AND MODULAR JACKS. EXISTING OUTLET BOXES AND CONDUITS SHALL

BE PRESERVED FOR REUSE.

7. CONTRACTOR SHALL REMOVE ALL DATA CABLES EXCEPT CATEGORY 6A OR UNLESS

OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE WITH THE COR PRIOR TO

REMOVING CABLES, OUTLETS, FACE PLATES, PATCH PANELS, AND PATCH CABLES.

8. CABLES SHALL NOT BE ABANDONED IN PLACE WITHOUT PRIOR APPROVAL OF THE

COR.

9. WHERE CABLES ARE TO BE REMOVED, CONTRACTOR SHALL COMPLETELY REMOVE

THE CABLE FROM OUTLET TO PATCH PANEL.

10. CONTRACTOR SHALL REMOVE NON-CATEGORY 6/6A FACE PLATES, MODULAR JACKS,

AND PATCH PANELS AFTER CUT OVER TO NEW CATEGORY 6A CABLE PLANT.

11. CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR J-HOOKS, THAT ARE NOT TO BE

REUSED SHALL BE PRESERVED FOR REUSE. COORDINATE WITH THE COR PRIOR TO

REMOVING CABLE SUPPORTS.

12. NURSE CALL SYSTEM TO BE MAINTAINED IN EXISTING LOCATIONS. CONTRACTOR

SHALL COORDINATE NEW EQUIPMENT LOCATION WITH THE COR PRIOR TO MOVING

THE NURSE CALL SYSTEM OR BEFORE WALL DEMOLITION BEGINS.

KEYED NOTES:

1. EXISTING TELECOMMUNICATIONS ROOM. DEMO ALL PATCH PANELS AND CABLING

RELATED TO THE IT/LV PROJECT. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,

ELECTRICAL CABLES AND EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT

DATA RELATED. REMOVE ALL IT RELATED CABLES FROM THE DEVICE TO THE SOURCE.

2. EXISTING CONDITIONS WERE NOT OBSERVED. REMOVE ALL IT DATA CABLES FROM

THE DEVICE TO THE SOURCE.

TRUE NORTH PLAN NORTH

Description Date

A/C Shaft

Adm. Asst.

A540

Elec.

A537A

Work Room A537F

Exam

Room 5 A555

Clos.

A556

Exam

Room 4 A557A

Surgery

Office A557B

Procedure

Room A557C

Procedure

Room A557D

Exam A558

Waiting

Area A559

Clerk A559A

Class Rm.

A564

Exam 7 A566

Exam 6 A567

Exam 5 A568

Elec.

A560

Tele A561

Soil A562

HAC

A562A

Stor.

A563A

Pain Nurse A563

Stor.

A564A

Stor.

A565A

Supp Clos A567A

Corridor C*5*4

Telesurgery

Office A554

Tlt.

A553

Skin and

Wound

Care Clinic A551

Closet A551A

Stor.

A551B

Stair 5 S*5*5

Medical

Service

Office B537

Medical

Service B538

Office B539

Chief Office B540

Adm Asst.

A541

Chief Med.

Svc.

A542

Dirty

Equipment A537B

Db. Wtr.

A539

Storage A537E

Clean

Supply A537D

Oxygen

Storage

Equipment

Room A537C

Office B537A

Med Svc B501

Office B503

Office B504

Conferece

Room B523

Cleric B524

Rolling

Storage B525

IV

Ante-Room B526

IV Prep B526A

IV Buff B526B

Closet B526C

Tlt.

B503A

Storage B506

Conference

Rm.

B507

Office B508

Office B509

Office B510

Office B511

Office B512

Office B513

Office B514

Office B515

Office B516

Office B517

Storage B515A

Closet B507A

Dispensing

Area B536

Office B535C

Stair 3 S*5*3

Storage B505H

Sig. Clos.

B505G

Office B518

Corridor C*5*5

Office B505

Tlt.

B505A

Elec.

B505B

HAC

B521E

Stor.

B518A

Staff Tlt.

B535B

Stor.

B521D

Elec.

B521B

Cart Stor.

B535

Narc. Vault B521A Chief

B522

Compound

Picking B527Unit Dose

B535A

Corridor C*5*1

Closet A554A

MICU

Penthouse B505D

Fan Room B505E

Stair 4 S*5*4

DNUP

DN

UP

DN

N

S.R.

A519

S.R.

A522

Soil. Util.

A515

Nurse Manager

A528

S.R

A512

S.R.

A511

Clean Supply

A5093

Storage

A5087

Storage

A5100

Nourishment

A508

Single Room

A504

Clean Linen

A5083

Staff Toilet

A5085

Nurse Station

A506

Single Room

- Bariatric

A5097

Single Room

- Bariatric

A5098

Single Room

- Bariatric

A5099

Single Room

- Bariatric

A5086

Single Room

- Negative Pressure

A5088Single Room

- Negative Pressure

A5089

Single Room

A5090Single Room

- Negative Pressure

A5091 Single Room

- Bariatric Negative Pressure

A5092

Signals

A5094

Elec.

A5095

HAC

A5084

Family Lounge

A578HUC

A581 Consult

A580

Staff Lounge

A510

Telem.

A509

Elec.

A514

Office

A582

Meds

A505

Physical Therapy

A579

Staff Tlt

A513

D.R.

A501

D.R.

A502

Elec.

A516

D.R.

A517D.R.

A518

D.R.

A520

D.R.

A521

D.R.

A523

Storage

A525

S.R.

A526

S.R.

A527

Bath

A511A

Bath

A512A

Bath

A521A

Bath

A520A

Bath

A522A

Bath

A519A

Corridor

C-5-1

Bath

A523A

Bath

A518A

Bath

A517A

Bath

A526A

Bath

A502A

Bath

A501A

Bath

A527A

Corridor

C-5-2

Storage

A549

Corridor

C-5-1

Corridor

C-5-1

Toilet

A5097A

Toilet

A5098A Toilet

A5099A Toilet

A5086A

Toilet

A5088A Toilet

A5089A

Toilet

A5090A

Toilet

A5091A

Toilet

A5092A

Areaway

A-1

Areaway

A-2

Corridor

C-5-4

Anteroom

A5092B

Anteroom

A5091B

Corridor

C-5-1

Clean Linen

A524

Pgm. Supp.

Asst.

A575

Tlt.

A577

Waiting Area

A550

Office

A574

Staff Physician

A573

Exam 1

A572

Exam 2

A571

Exam 3

A570

Exam 4

A569

Stair #11

A5096

Clean Supply

A503

Bath

A504B

A L

IG

N

ALIGN

UPUP

LOW VOLTAGE/ IT

Ross & Baruzzini Inc.

1600 Riveredge Parkway NW Suite 900 Atlanta, GA 30328

Project Number

Building Number

Drawing Number

Drawn By:Checked By:Issue Date:

Location

Project TitlePhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANT

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

100% CONSTRUCTION

DOCUMENTS

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

Scale:

FULLY SPRINKLERED

1/16" = 1'-0"

TD-160-C.1.5

TECHNOLOGY DEMOLITION FIFTH

FLOOR OVERALL PLAN

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST. CINCINNATI, OH. 45220

539-21-701

TL

04-MAY-2022

PR

C1

1/16" = 1'-0"

TECHNOLOGY DEMOLITION FIFTH FLOOR OVERALL PLAN

GENERAL NOTES:

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS OTHERWISE NOTED.

3. EXISTING TELECOMMUNICATIONS ROOM OR IT CLOSET.

CONTRACTOR SHALL DEMO ALL PATCH PANELS AND CABLING

RELATED TO THIS PROJECT. CONTRACTOR SHALL REMOVE ALL

DATA CABLES FROM THE DEVICE TO THE SOURCE. CONTRACTOR

SHALL COORDINATE WITH THE COR PRIOR TO BEGINNING WORK IN

EACH TELECOM ROOM (TR) OR IT CLOSET.

4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT, ELECTRICAL

CABLES AND EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT

DATA RELATED. COORDINATE WITH COR PRIOR TO REMOVING

CABLING FROM WALL FIELDS OR FROM WALL MOUNTED EQUIPMENT.

5. BUILDING AUTOMATION SYSTEMS (BAS), PACS, AND ELECTRONIC

SECURITY SYSTEMS CABLES SHALL NOT BE REMOVED. COORDINATE

WITH COR TO IDENTIFY BAS, PACS, OR SECURITY CABLES.

6. EXISTING TELECOMMUNICATIONS OUTLET. CONTRACTOR SHALL

REMOVE ALL DEVICE FACEPLATES AND MODULAR JACKS. EXISTING

OUTLET BOXES AND CONDUITS SHALL BE PRESERVED FOR REUSE.

7. CONTRACTOR SHALL REMOVE ALL DATA CABLES EXCEPT CATEGORY

6A OR UNLESS OTHERWISE NOTED. CONTRACTOR SHALL

COORDINATE WITH THE COR PRIOR TO REMOVING CABLES,

OUTLETS, FACE PLATES, PATCH PANELS, AND PATCH CABLES.

8. CABLES SHALL NOT BE ABANDONED IN PLACE WITHOUT PRIOR

APPROVAL OF THE COR.

9. WHERE CABLES ARE TO BE REMOVED, CONTRACTOR SHALL

COMPLETELY REMOVE THE CABLE FROM OUTLET TO PATCH PANEL.

10. CONTRACTOR SHALL REMOVE NON-CATEGORY 6/6A FACE PLATES,

MODULAR JACKS, AND PATCH PANELS AFTER CUT OVER TO NEW

CATEGORY 6A CABLE PLANT.

11. CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR J-HOOKS, THAT ARE

NOT TO BE REUSED SHALL BE PRESERVED FOR REUSE.

COORDINATE WITH THE COR PRIOR TO REMOVING CABLE

SUPPORTS.

12. NURSE CALL SYSTEM TO BE MAINTAINED IN EXISTING LOCATIONS.

CONTRACTOR SHALL COORDINATE NEW EQUIPMENT LOCATION WITH

THE COR PRIOR TO MOVING THE NURSE CALL SYSTEM OR BEFORE

WALL DEMOLITION BEGINS.

KEYED NOTES:

1. EXISTING TELECOMMUNICATIONS ROOM. DEMO ALL PATCH PANELS

AND CABLING RELATED TO THE IT/LV PROJECT. DO NOT REMOVE ANY

WALL MOUNT EQUIPMENT, ELECTRICAL CABLES AND EQUIPMENT, OR

ANY CABLING OR DEVICE THAT IS NOT DATA RELATED. REMOVE ALL

IT RELATED CABLES FROM THE DEVICE TO THE SOURCE. REMOVE

ALL CABLE TRAY ORIGINATING FROM THIS SPACE. TO AFFORD

CEILING SPACE AND ACCOMIDATE PHASING OF NEW PATHWAY

CREATION, PLACE ALL CABLING WITHIN EXISTING CABLE TRAYS IN J-

HOOK SUPPORTS ON EXISTING THREADED ROD SUPPORTS.

D B

A

Medical

Service

Office B537

Medical

Service B538

Office B539

Chief Office

Dirty

Equipment A537B

Db. Wtr.

A539

Oxygen

Storage

Equipment

Room A537C

Office B537A

Med Svc B501

Office B503

Office B504

Conferece

Room B523

Cleric B524

Rolling

Storage B525

IV

Ante-Room B526

IV Prep B526A

IV Buff B526B

Closet B526C

Tlt.

B503A

Storage B506

Conference

Rm.

B507

Office B508

Office B509

Office B510

Office B511

Office B512

Office B513

Office B514

Office B515

Office B516

Office B517

Storage B515A

Closet B507A

Dispensing

Area B536

Office B535C

Stair 3 S*5*3

Storage B505H

Sig. Clos.

B505G

Office B518

Corridor C*5*5

Office B505

Tlt.

B505A

Elec.

B505B

HAC

B521E

Stor.

B518A

Staff Tlt.

B535B

Stor.

B521D

Elec.

B521B

Cart Stor.

B535

Narc. Vault B521A Chief

B522

Compound

Picking B527Unit Dose

B535A

MICU

Penthouse B505D

Fan Room B505E

Stair 4 S*5*4

DN

UP

DN

1 3

2 2

3 3

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

LOW VOLTAGE/ IT

Ross & Baruzzini Inc.

1600 Riveredge Parkway NW Suite 900 Atlanta, GA 30328

Project Number

Building Number

Drawing Number

Drawn By:Checked By:Issue Date:

Location

Project TitlePhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANT

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

100% CONSTRUCTION

DOCUMENTS

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

Scale:

FULLY SPRINKLERED

1/8" = 1'-0"

TD-161-C.1.5

TECHNOLOGY DEMOLITION FIFTH

FLOOR PARTIAL PLAN - A

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST. CINCINNATI, OH. 45220

539-21-701

TL

04-MAY-2022

PR

C1

1/8" = 1'-0"

TECHNOLOGY DEMOLITION FIFTH FLOOR PARTIAL PLAN - A

D

B

A

GENERAL NOTES:

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS OTHERWISE NOTED.

3. EXISTING TELECOMMUNICATIONS ROOM OR IT CLOSET. CONTRACTOR SHALL DEMO

ALL PATCH PANELS AND CABLING RELATED TO THIS PROJECT. CONTRACTOR SHALL

REMOVE ALL DATA CABLES FROM THE DEVICE TO THE SOURCE. CONTRACTOR SHALL

COORDINATE WITH THE COR PRIOR TO BEGINNING WORK IN EACH TELECOM ROOM

(TR) OR IT CLOSET.

4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT, ELECTRICAL CABLES AND

EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT DATA RELATED. COORDINATE

WITH COR PRIOR TO REMOVING CABLING FROM WALL FIELDS OR FROM WALL

MOUNTED EQUIPMENT.

5. BUILDING AUTOMATION SYSTEMS (BAS), PACS, AND ELECTRONIC SECURITY SYSTEMS

CABLES SHALL NOT BE REMOVED. COORDINATE WITH COR TO IDENTIFY BAS, PACS,

OR SECURITY CABLES.

6. EXISTING TELECOMMUNICATIONS OUTLET. CONTRACTOR SHALL REMOVE ALL DEVICE

FACEPLATES AND MODULAR JACKS. EXISTING OUTLET BOXES AND CONDUITS SHALL

BE PRESERVED FOR REUSE.

7. CONTRACTOR SHALL REMOVE ALL DATA CABLES EXCEPT CATEGORY 6A OR UNLESS

OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE WITH THE COR PRIOR TO

REMOVING CABLES, OUTLETS, FACE PLATES, PATCH PANELS, AND PATCH CABLES.

8. CABLES SHALL NOT BE ABANDONED IN PLACE WITHOUT PRIOR APPROVAL OF THE

COR.

9. WHERE CABLES ARE TO BE REMOVED, CONTRACTOR SHALL COMPLETELY REMOVE

THE CABLE FROM OUTLET TO PATCH PANEL.

10. CONTRACTOR SHALL REMOVE NON-CATEGORY 6/6A FACE PLATES, MODULAR JACKS,

AND PATCH PANELS AFTER CUT OVER TO NEW CATEGORY 6A CABLE PLANT.

11. CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR J-HOOKS, THAT ARE NOT TO BE

REUSED SHALL BE PRESERVED FOR REUSE. COORDINATE WITH THE COR PRIOR TO

REMOVING CABLE SUPPORTS.

12. NURSE CALL SYSTEM TO BE MAINTAINED IN EXISTING LOCATIONS. CONTRACTOR

SHALL COORDINATE NEW EQUIPMENT LOCATION WITH THE COR PRIOR TO MOVING

THE NURSE CALL SYSTEM OR BEFORE WALL DEMOLITION BEGINS.

KEYED NOTES:

1. EXISTING TELECOMMUNICATIONS ROOM. DEMO ALL PATCH PANELS AND CABLING

RELATED TO THE IT/LV PROJECT. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,

ELECTRICAL CABLES AND EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT

DATA RELATED. REMOVE ALL IT RELATED CABLES FROM THE DEVICE TO THE SOURCE.

2. EXISTING CONDITIONS WERE NOT OBSERVED. REMOVE ALL IT DATA CABLES FROM

THE DEVICE TO THE SOURCE.

Adm. Asst.

A540

128 SF

Elec.

A537A

Work Room A537F

Chief Office B540

Adm Asst.

A541

Chief Med.

Svc.

A542

Storage A537E

Clean

Supply A537D

Corridor C*5*1

N

S.R.

A519

S.R.

A522

Soil. Util.

A515

Nurse Manager

A528

S.R

A512

S.R.

A511

Clean Supply

A5093

Storage

A5087

Storage

A5100

Nourishment

A508

Single Room

A504

Clean Linen

A5083

Staff Toilet

A5085

Nurse Station

A506

Single Room

- Bariatric

A5097

Single Room

- Bariatric

A5098

Single Room

- Bariatric

A5099

Single Room

- Bariatric

A5086

Single Room

- Negative Pressure

A5088Single Room

- Negative Pressure

A5089

Single Room

A5090Single Room

- Negative Pressure

A5091 Single Room

- Bariatric Negative Pressure

A5092

Signals

A5094

Elec.

A5095

HAC

A5084

Family Lounge

A578HUC

A581 Consult

A580

Staff Lounge

A510

Telem.

A509

Elec.

A514

Office

A582

Meds

A505

Physical Therapy

A579

Staff Tlt

A513

D.R.

A501

D.R.

A502

Elec.

A516

D.R.

A517D.R.

A518

D.R.

A520

D.R.

A521

D.R.

A523

Storage

A525

S.R.

A526

S.R.

A527

Bath

A511A

Bath

A512A

Bath

A521A

Bath

A520A

Bath

A522A

Bath

A519A

Corridor

C-5-1

Bath

A523A

Bath

A518A

Bath

A517A

Bath

A526A

Bath

A502A

Bath

A501A

Bath

A527A

Corridor

C-5-2

Storage

A549

Corridor

C-5-1

Corridor

C-5-1

Toilet

A5097A

Toilet

A5098A Toilet

A5099A Toilet

A5086A

Toilet

A5088A Toilet

A5089A

Toilet

A5090A

Toilet

A5091A

Toilet

A5092A

Areaway

A-1

Areaway

A-2

Corridor

C-5-4

Anteroom

A5092B

Anteroom

A5091B

Corridor

C-5-1

Clean Linen

A524

Pgm. Supp.

Tlt.

A577

Physician

Exam 1

A572

Exam 2

A571

Exam 3

Exam 4

Stair #11

A5096

Clean Supply

A503

Bath

A504B

A L

IG

N

ALIGN

UPUP

3 3 3

1 1

2 2

2 2

2 2

2 2

2 2

2 22 2 2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2 2

LOW VOLTAGE/ IT

Ross & Baruzzini Inc.

1600 Riveredge Parkway NW Suite 900 Atlanta, GA 30328

Project Number

Building Number

Drawing Number

Drawn By:Checked By:Issue Date:

Location

Project TitlePhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANT

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

100% CONSTRUCTION

DOCUMENTS

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

Scale:

FULLY SPRINKLERED

1/8" = 1'-0"

TD-162-C.1.5

TECHNOLOGY DEMOLITION FIFTH

FLOOR PARTIAL PLAN - B

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST. CINCINNATI, OH. 45220

539-21-701

TL

04-MAY-2022

PR

C1

1/8" = 1'-0"

TECHNOLOGY DEMOLITION FIFTH FLOOR PARTIAL PLAN - B

D B

A

GENERAL NOTES:

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS OTHERWISE NOTED.

3. EXISTING TELECOMMUNICATIONS ROOM OR IT CLOSET. CONTRACTOR SHALL DEMO

ALL PATCH PANELS AND CABLING RELATED TO THIS PROJECT. CONTRACTOR SHALL

REMOVE ALL DATA CABLES FROM THE DEVICE TO THE SOURCE. CONTRACTOR SHALL

COORDINATE WITH THE COR PRIOR TO BEGINNING WORK IN EACH TELECOM ROOM

(TR) OR IT CLOSET.

4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT, ELECTRICAL CABLES AND

EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT DATA RELATED. COORDINATE

WITH COR PRIOR TO REMOVING CABLING FROM WALL FIELDS OR FROM WALL

MOUNTED EQUIPMENT.

5. BUILDING AUTOMATION SYSTEMS (BAS), PACS, AND ELECTRONIC SECURITY SYSTEMS

CABLES SHALL NOT BE REMOVED. COORDINATE WITH COR TO IDENTIFY BAS, PACS,

OR SECURITY CABLES.

6. EXISTING TELECOMMUNICATIONS OUTLET. CONTRACTOR SHALL REMOVE ALL DEVICE

FACEPLATES AND MODULAR JACKS. EXISTING OUTLET BOXES AND CONDUITS SHALL

BE PRESERVED FOR REUSE.

7. CONTRACTOR SHALL REMOVE ALL DATA CABLES EXCEPT CATEGORY 6A OR UNLESS

OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE WITH THE COR PRIOR TO

REMOVING CABLES, OUTLETS, FACE PLATES, PATCH PANELS, AND PATCH CABLES.

8. CABLES SHALL NOT BE ABANDONED IN PLACE WITHOUT PRIOR APPROVAL OF THE

COR.

9. WHERE CABLES ARE TO BE REMOVED, CONTRACTOR SHALL COMPLETELY REMOVE

THE CABLE FROM OUTLET TO PATCH PANEL.

10. CONTRACTOR SHALL REMOVE NON-CATEGORY 6/6A FACE PLATES, MODULAR JACKS,

AND PATCH PANELS AFTER CUT OVER TO NEW CATEGORY 6A CABLE PLANT.

11. CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR J-HOOKS, THAT ARE NOT TO BE

REUSED SHALL BE PRESERVED FOR REUSE. COORDINATE WITH THE COR PRIOR TO

REMOVING CABLE SUPPORTS.

12. NURSE CALL SYSTEM TO BE MAINTAINED IN EXISTING LOCATIONS. CONTRACTOR

SHALL COORDINATE NEW EQUIPMENT LOCATION WITH THE COR PRIOR TO MOVING

THE NURSE CALL SYSTEM OR BEFORE WALL DEMOLITION BEGINS.

KEYED NOTES:

1. EXISTING TELECOMMUNICATIONS ROOM. DEMO ALL PATCH PANELS AND CABLING

RELATED TO THE IT/LV PROJECT. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,

ELECTRICAL CABLES AND EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT

DATA RELATED. REMOVE ALL IT RELATED CABLES FROM THE DEVICE TO THE SOURCE.

2. EXISTING CONDITIONS WERE NOT OBSERVED. REMOVE ALL IT DATA CABLES FROM

THE DEVICE TO THE SOURCE.

Exam

Room 5 A555

Clos.

A556

Exam

Room 4 A557A

Surgery

Office A557B

Procedure

Room A557C

Procedure

Room A557D

Exam A558

Waiting

Area A559

Clerk A559A

Class Rm.

A564

Exam 7 A566

Exam 6 A567

Exam 5 A568

Elec.

A560

Tele A561

Soil A562

HAC

A562A

Stor.

A563A

Pain Nurse A563

Stor.

A564A

Stor.

A565A

Supp Clos A567A

Corridor C*5*4

Telesurgery

Office A554

Tlt.

A553

Skin and

Wound

Care Clinic A551

Closet A551A

Stor.

A551B

Stair 5 S*5*5

Closet A554A

DNUP

Pgm. Supp.

Asst.

A575

Tlt.

A577

Waiting Area

A550

Office

A574

Staff Physician

A573

Exam 1

A572

Exam 2

A571

Exam 3

A570

Exam 4

A569

3 3

3 3

3 3

1 1

3 3

2 2

2 2

2 2

2 2

LOW VOLTAGE/ IT

Ross & Baruzzini Inc.

1600 Riveredge Parkway NW Suite 900 Atlanta, GA 30328

Project Number

Building Number

Drawing Number

Drawn By:Checked By:Issue Date:

Location

Project TitlePhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANT

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

100% CONSTRUCTION

DOCUMENTS

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

Scale:

FULLY SPRINKLERED

1/8" = 1'-0"

TD-163-C.1.5

TECHNOLOGY DEMOLITION FIFTH

FLOOR PARTIAL PLAN - D

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST. CINCINNATI, OH. 45220

539-21-701

TL

04-MAY-2022

PR

C1

1/8" = 1'-0"

TECHNOLOGY DEMOLITION FIFTH FLOOR PARTIAL PLAN - D

D B

A

GENERAL NOTES:

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS OTHERWISE NOTED.

3. EXISTING TELECOMMUNICATIONS ROOM OR IT CLOSET. CONTRACTOR SHALL DEMO

ALL PATCH PANELS AND CABLING RELATED TO THIS PROJECT. CONTRACTOR SHALL

REMOVE ALL DATA CABLES FROM THE DEVICE TO THE SOURCE. CONTRACTOR SHALL

COORDINATE WITH THE COR PRIOR TO BEGINNING WORK IN EACH TELECOM ROOM

(TR) OR IT CLOSET.

4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT, ELECTRICAL CABLES AND

EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT DATA RELATED. COORDINATE

WITH COR PRIOR TO REMOVING CABLING FROM WALL FIELDS OR FROM WALL

MOUNTED EQUIPMENT.

5. BUILDING AUTOMATION SYSTEMS (BAS), PACS, AND ELECTRONIC SECURITY SYSTEMS

CABLES SHALL NOT BE REMOVED. COORDINATE WITH COR TO IDENTIFY BAS, PACS,

OR SECURITY CABLES.

6. EXISTING TELECOMMUNICATIONS OUTLET. CONTRACTOR SHALL REMOVE ALL DEVICE

FACEPLATES AND MODULAR JACKS. EXISTING OUTLET BOXES AND CONDUITS SHALL

BE PRESERVED FOR REUSE.

7. CONTRACTOR SHALL REMOVE ALL DATA CABLES EXCEPT CATEGORY 6A OR UNLESS

OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE WITH THE COR PRIOR TO

REMOVING CABLES, OUTLETS, FACE PLATES, PATCH PANELS, AND PATCH CABLES.

8. CABLES SHALL NOT BE ABANDONED IN PLACE WITHOUT PRIOR APPROVAL OF THE

COR.

9. WHERE CABLES ARE TO BE REMOVED, CONTRACTOR SHALL COMPLETELY REMOVE

THE CABLE FROM OUTLET TO PATCH PANEL.

10. CONTRACTOR SHALL REMOVE NON-CATEGORY 6/6A FACE PLATES, MODULAR JACKS,

AND PATCH PANELS AFTER CUT OVER TO NEW CATEGORY 6A CABLE PLANT.

11. CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR J-HOOKS, THAT ARE NOT TO BE

REUSED SHALL BE PRESERVED FOR REUSE. COORDINATE WITH THE COR PRIOR TO

REMOVING CABLE SUPPORTS.

12. NURSE CALL SYSTEM TO BE MAINTAINED IN EXISTING LOCATIONS. CONTRACTOR

SHALL COORDINATE NEW EQUIPMENT LOCATION WITH THE COR PRIOR TO MOVING

THE NURSE CALL SYSTEM OR BEFORE WALL DEMOLITION BEGINS.

KEYED NOTES:

1. EXISTING TELECOMMUNICATIONS ROOM. DEMO ALL PATCH PANELS AND CABLING

RELATED TO THE IT/LV PROJECT. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,

ELECTRICAL CABLES AND EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT

DATA RELATED. REMOVE ALL IT RELATED CABLES FROM THE DEVICE TO THE SOURCE.

2. EXISTING CONDITIONS WERE NOT OBSERVED. REMOVE ALL IT DATA CABLES FROM

THE DEVICE TO THE SOURCE.

Waiting

Room

Nurse

Station A600A603A604

A605

HAC

A606

A607

A608

A609

D.R.

A611

S.R.

A612

S.R. (Neg.

Pres.)

A614

Elec.

A615

Soiled

Utility A616

Elec.

A617

CL. Lin.

A618

D.R.

A619

S.R.

A620

S.R. (Neg.

Pres.)

A621

D.R.

A622

D.R.

A623

S.R. (Neg.

Pres.)

A624

CL. Supp.

A625

D.R.

A626

Stair 2 S*6*2

Storage A628

D.R.

A629

Nourish.

A630

D.R.

A631

Service

Lobby A632

Elec.

A632E

Medical

Conf.

A634B

Tlt.

A635

Phys.

Work Rm.

A632D

LKRS.

A637B

HAC

A637A

DB. Wtr.

A639

Research

Pulmonary

Lab.

A640

HHN Off.

A641

Chief

Medical

Res.

A642

A643

Stair 1 S*6*1

Elec.

A645

Equip. Stor.

A646

D.R.

A647

A648

D.R.

A649

Stair 5 S*6*5

A651

A652

A654 A655

A656 A657A658

A659

Elec.

A660

Elec.

A661

Soil. Util.

A662

A663

A663A

A664

A668 A669

A671A

A671

A672

CL. Lin.

A673

HAC

A674

A675A676

Tlt.

A604A

Tlt.

A607A

Tlt.

A611A

Tlt.

A612A

Tlt.

A614A

Tlt.

A619A

Tlt.

A621A

Tlt.

A620A

Tlt.

A622A

Tlt.

A623A

Tlt.

A626ATlt.

A624A

Tlt.

A629A

Tlt.

A631A

Trash

Chute A637

Medical

Conf.

A634C

Meeting

Room A634A

Sig. Clos.

A645A

Tlt.

A647A

Tlt.

A649A

Tlt.

A651A

Tlt.

A654A

Tlt.

A655A

Tlt.

A656A

Toilet A659A

Tlt.

A664A

A667A

A670

Tlt.

A675A

Tlt.

A672A

Corridor C*6*1

Off.

B601

Elec.

B619B

Soiled B619A

Echo.

B604

Storage B605

IV Tech.

Off.

B606

Conf. Rm.

B607

Stair 3 S*6*3

Exam B609

Exam B610

Office B611A

Exam B612A

Exam B612B

Exam B612C

Exam B612D

Toilet B613

Exam B614

Toilet B615

Exam B616

Exam B617

Secretary B618

Elec.

B607A

Sig. Clos.

B606A

Tlt.

B605A

Tlt.

B603

Adm. Asst.

B620

Social

Work Off.

B621

Phys.

B622

Conf.

Room B623

Chief

Admn.

Asst.

B624

Chief Phys.

B625

Phys.

B626

Phys.

B627

Phys.

B628

Phys.

B629

Clos.

B625A

Corridor C*6*5

Stor.

B632

Stor.

B633

Ward Stor.

B635

Pulmonary

Func. LAB B636

HAC

B634

Tlt.

B620A

Corridor C*6*2

Exam B611B

Closet B609A

Storage A646A

A/C Shaft A/C Shaft

A6002A

A6002

A6003AA6003A6004A

A6005

A6005A

A6006

A6006B

A6014A

A6013

A6013AA6012A

A6012

A6009

A6010

A6007B

A6007

A6007A

A6006A

A6004

A6000

A6008

C-6-6

A6001

C-6-6A

AREAWAYAREAWAY

A6011

A667

Tlt.

A666

C-6-3A

A658A

A657A

C-6-3A

A613

C-6-2A Tlt.

A608A

A602 A601

DN UP DNUP

DN UP

DN

UP

LOW VOLTAGE/ IT

Ross & Baruzzini Inc.

1600 Riveredge Parkway NW Suite 900 Atlanta, GA 30328

Project Number

Building Number

Drawing Number

Drawn By:Checked By:Issue Date:

Location

Project TitlePhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANT

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

100% CONSTRUCTION

DOCUMENTS

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

Scale:

FULLY SPRINKLERED

1/16" = 1'-0"

TD-170-C.1.6

TECHNOLOGY DEMOLITION SIXTH

FLOOR OVERALL PLAN

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST. CINCINNATI, OH. 45220

539-21-701

TL

04-MAY-2022

PR

C1

1/16" = 1'-0"

TECHNOLOGY DEMOLITION SIXTH FLOOR OVERALL PLAN

GENERAL NOTES:

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS OTHERWISE NOTED.

3. EXISTING TELECOMMUNICATIONS ROOM OR IT CLOSET.

CONTRACTOR SHALL DEMO ALL PATCH PANELS AND CABLING

RELATED TO THIS PROJECT. CONTRACTOR SHALL REMOVE ALL

DATA CABLES FROM THE DEVICE TO THE SOURCE. CONTRACTOR

SHALL COORDINATE WITH THE COR PRIOR TO BEGINNING WORK IN

EACH TELECOM ROOM (TR) OR IT CLOSET.

4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT, ELECTRICAL

CABLES AND EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT

DATA RELATED. COORDINATE WITH COR PRIOR TO REMOVING

CABLING FROM WALL FIELDS OR FROM WALL MOUNTED EQUIPMENT.

5. BUILDING AUTOMATION SYSTEMS (BAS), PACS, AND ELECTRONIC

SECURITY SYSTEMS CABLES SHALL NOT BE REMOVED. COORDINATE

WITH COR TO IDENTIFY BAS, PACS, OR SECURITY CABLES.

6. EXISTING TELECOMMUNICATIONS OUTLET. CONTRACTOR SHALL

REMOVE ALL DEVICE FACEPLATES AND MODULAR JACKS. EXISTING

OUTLET BOXES AND CONDUITS SHALL BE PRESERVED FOR REUSE.

7. CONTRACTOR SHALL REMOVE ALL DATA CABLES EXCEPT CATEGORY

6A OR UNLESS OTHERWISE NOTED. CONTRACTOR SHALL

COORDINATE WITH THE COR PRIOR TO REMOVING CABLES,

OUTLETS, FACE PLATES, PATCH PANELS, AND PATCH CABLES.

8. CABLES SHALL NOT BE ABANDONED IN PLACE WITHOUT PRIOR

APPROVAL OF THE COR.

9. WHERE CABLES ARE TO BE REMOVED, CONTRACTOR SHALL

COMPLETELY REMOVE THE CABLE FROM OUTLET TO PATCH PANEL.

10. CONTRACTOR SHALL REMOVE NON-CATEGORY 6/6A FACE PLATES,

MODULAR JACKS, AND PATCH PANELS AFTER CUT OVER TO NEW

CATEGORY 6A CABLE PLANT.

11. CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR J-HOOKS, THAT ARE

NOT TO BE REUSED SHALL BE PRESERVED FOR REUSE.

COORDINATE WITH THE COR PRIOR TO REMOVING CABLE

SUPPORTS.

12. NURSE CALL SYSTEM TO BE MAINTAINED IN EXISTING LOCATIONS.

CONTRACTOR SHALL COORDINATE NEW EQUIPMENT LOCATION WITH

THE COR PRIOR TO MOVING THE NURSE CALL SYSTEM OR BEFORE

WALL DEMOLITION BEGINS.

KEYED NOTES:

1. EXISTING TELECOMMUNICATIONS ROOM. DEMO ALL PATCH PANELS

AND CABLING RELATED TO THE IT/LV PROJECT. DO NOT REMOVE ANY

WALL MOUNT EQUIPMENT, ELECTRICAL CABLES AND EQUIPMENT, OR

ANY CABLING OR DEVICE THAT IS NOT DATA RELATED. REMOVE ALL

IT RELATED CABLES FROM THE DEVICE TO THE SOURCE. REMOVE

ALL CABLE TRAY ORIGINATING FROM THIS SPACE. TO AFFORD

CEILING SPACE AND ACCOMIDATE PHASING OF NEW PATHWAY

CREATION, PLACE ALL CABLING WITHIN EXISTING CABLE TRAYS IN J-

HOOK SUPPORTS ON EXISTING THREADED ROD SUPPORTS.

D B

A

Tlt.

A635

DB. Wtr.

A639

Research

Pulmonary

Lab.

A640

Medical

Conf.

A634C

Off.

B601

Elec.

B619B

Soiled B619A

Echo.

B604

Storage B605

IV Tech.

Off.

B606

Conf. Rm.

B607

Stair 3 S*6*3

Exam B609

Exam B610

Office B611A

Exam B612A

Exam B612B

Exam B612C

Exam B612D

Toilet B613

Exam B614

Toilet B615

Exam B616

Exam B617

Secretary B618

Elec.

B607A

Sig. Clos.

B606A

Tlt.

B605A

Tlt.

B603

Adm. Asst.

B620

Social

Work Off.

B621

Phys.

B622

Conf.

Room B623

Chief

Admn.

Asst.

B624

Chief Phys.

B625

Phys.

B626

Phys.

B627

Phys.

B628

Phys.

B629

Clos.

B625A

Corridor C*6*5

Stor.

B632

Stor.

B633

Ward Stor.

B635

Pulmonary

Func. LAB B636

HAC

B634

Tlt.

B620A

Exam B611B

Closet B609A

DN

UP

3 24

3 3

31 2

3 3

2 2

2 2

LOW VOLTAGE/ IT

Ross & Baruzzini Inc.

1600 Riveredge Parkway NW Suite 900 Atlanta, GA 30328

Project Number

Building Number

Drawing Number

Drawn By:Checked By:Issue Date:

Location

Project TitlePhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANT

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

100% CONSTRUCTION

DOCUMENTS

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

Scale:

FULLY SPRINKLERED

1/8" = 1'-0"

TD-171-C.1.6

TECHNOLOGY DEMOLITION SIXTH

FLOOR PARTIAL PLAN - A

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST. CINCINNATI, OH. 45220

539-21-701

TL

04-MAY-2022

PR

C1

1/8" = 1'-0"

TECHNOLOGY DEMOLITION SIXTH FLOOR PARTIAL PLAN - A

D B

A

GENERAL NOTES:

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS OTHERWISE NOTED.

3. EXISTING TELECOMMUNICATIONS ROOM OR IT CLOSET. CONTRACTOR SHALL DEMO

ALL PATCH PANELS AND CABLING RELATED TO THIS PROJECT. CONTRACTOR SHALL

REMOVE ALL DATA CABLES FROM THE DEVICE TO THE SOURCE. CONTRACTOR SHALL

COORDINATE WITH THE COR PRIOR TO BEGINNING WORK IN EACH TELECOM ROOM

(TR) OR IT CLOSET.

4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT, ELECTRICAL CABLES AND

EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT DATA RELATED. COORDINATE

WITH COR PRIOR TO REMOVING CABLING FROM WALL FIELDS OR FROM WALL

MOUNTED EQUIPMENT.

5. BUILDING AUTOMATION SYSTEMS (BAS), PACS, AND ELECTRONIC SECURITY SYSTEMS

CABLES SHALL NOT BE REMOVED. COORDINATE WITH COR TO IDENTIFY BAS, PACS,

OR SECURITY CABLES.

6. EXISTING TELECOMMUNICATIONS OUTLET. CONTRACTOR SHALL REMOVE ALL DEVICE

FACEPLATES AND MODULAR JACKS. EXISTING OUTLET BOXES AND CONDUITS SHALL

BE PRESERVED FOR REUSE.

7. CONTRACTOR SHALL REMOVE ALL DATA CABLES EXCEPT CATEGORY 6A OR UNLESS

OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE WITH THE COR PRIOR TO

REMOVING CABLES, OUTLETS, FACE PLATES, PATCH PANELS, AND PATCH CABLES.

8. CABLES SHALL NOT BE ABANDONED IN PLACE WITHOUT PRIOR APPROVAL OF THE

COR.

9. WHERE CABLES ARE TO BE REMOVED, CONTRACTOR SHALL COMPLETELY REMOVE

THE CABLE FROM OUTLET TO PATCH PANEL.

10. CONTRACTOR SHALL REMOVE NON-CATEGORY 6/6A FACE PLATES, MODULAR JACKS,

AND PATCH PANELS AFTER CUT OVER TO NEW CATEGORY 6A CABLE PLANT.

11. CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR J-HOOKS, THAT ARE NOT TO BE

REUSED SHALL BE PRESERVED FOR REUSE. COORDINATE WITH THE COR PRIOR TO

REMOVING CABLE SUPPORTS.

12. NURSE CALL SYSTEM TO BE MAINTAINED IN EXISTING LOCATIONS. CONTRACTOR

SHALL COORDINATE NEW EQUIPMENT LOCATION WITH THE COR PRIOR TO MOVING

THE NURSE CALL SYSTEM OR BEFORE WALL DEMOLITION BEGINS.

KEYED NOTES:

1. EXISTING TELECOMMUNICATIONS ROOM. DEMO ALL PATCH PANELS AND CABLING

RELATED TO THE IT/LV PROJECT. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,

ELECTRICAL CABLES AND EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT

DATA RELATED. REMOVE ALL IT RELATED CABLES FROM THE DEVICE TO THE SOURCE.

2. EXISTING CONDITIONS WERE NOT OBSERVED. REMOVE ALL IT DATA CABLES FROM

THE DEVICE TO THE SOURCE.

Waiting

Room

158 SF

Nurse

Station A600A603A604

A605

HAC

A606

A607

A608

A609

D.R.

A611

S.R.

A612

S.R. (Neg.

Pres.)

A614

Elec.

A615

Soiled

Utility A616

Elec.

A617

CL. Lin.

A618

D.R.

A619

S.R.

A620

S.R. (Neg.

Pres.)

A621

D.R.

A622

D.R.

A623

S.R. (Neg.

Pres.)

A624

CL. Supp.

A625

D.R.

A626

Stair 2 S*6*2

Storage A628

D.R.

A629

Nourish.

A630

D.R.

A631

Service

Lobby A632

Elec.

A632E

Medical

Conf.

A634B

A635

Phys.

Work Rm.

A632D

LKRS.

A637B

HAC

A637A

HHN Off.

A641

Chief

Medical

Res.

A642

A643

Stair 1 S*6*1

Elec.

A645

Equip. Stor.

A646

D.R.

A647

A669

A671A

A675A676

Tlt.

A604A

Tlt.

A607A

Tlt.

A611A

Tlt.

A612A

Tlt.

A614A

Tlt.

A619A

Tlt.

A621A

Tlt.

A620A

Tlt.

A622A

Tlt.

A623A

Tlt.

A626ATlt.

A624A

Tlt.

A629A

Tlt.

A631A

Trash

Chute A637

Meeting

Room A634A

Sig. Clos.

A645A

Tlt.

A675A

Tlt.

A672A

Corridor C*6*1

Corridor C*6*2

Storage A646A

A/C Shaft A/C Shaft

A6002A

A6002

A6003AA6003A6004A

A6005

A6005A

A6006

A6006B

A6014A

A6013

A6013AA6012A

A6012

A6009

A6010

A6007B

A6007

A6007A

A6006A

A6004

A6000

A6008

C-6-6

A6001

C-6-6A

AREAWAYAREAWAY

A6011

A613

C-6-2A Tlt.

A608A

A602 A601

DN UP

DN UP

3 3

3 3

1 1

3 4 4 3 2

1 3

32 23

3 3 3 3

2 2

2 2

2 2

2 2

2 2

2 2 2

2 2 2

LOW VOLTAGE/ IT

Ross & Baruzzini Inc.

1600 Riveredge Parkway NW Suite 900 Atlanta, GA 30328

Project Number

Building Number

Drawing Number

Drawn By:Checked By:Issue Date:

Location

Project TitlePhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANT

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

100% CONSTRUCTION

DOCUMENTS

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

Scale:

FULLY SPRINKLERED

1/8" = 1'-0"

TD-172-C.1.6

TECHNOLOGY DEMOLITION SIXTH

FLOOR PARTIAL PLAN - B

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST. CINCINNATI, OH. 45220

539-21-701

TL

04-MAY-2022

PR

C1

1/8" = 1'-0"

TECHNOLOGY DEMOLITION SIXTH FLOOR PARTIAL PLAN - B

D B

A

GENERAL NOTES:

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS OTHERWISE NOTED.

3. EXISTING TELECOMMUNICATIONS ROOM OR IT CLOSET. CONTRACTOR SHALL DEMO

ALL PATCH PANELS AND CABLING RELATED TO THIS PROJECT. CONTRACTOR SHALL

REMOVE ALL DATA CABLES FROM THE DEVICE TO THE SOURCE. CONTRACTOR SHALL

COORDINATE WITH THE COR PRIOR TO BEGINNING WORK IN EACH TELECOM ROOM

(TR) OR IT CLOSET.

4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT, ELECTRICAL CABLES AND

EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT DATA RELATED. COORDINATE

WITH COR PRIOR TO REMOVING CABLING FROM WALL FIELDS OR FROM WALL

MOUNTED EQUIPMENT.

5. BUILDING AUTOMATION SYSTEMS (BAS), PACS, AND ELECTRONIC SECURITY SYSTEMS

CABLES SHALL NOT BE REMOVED. COORDINATE WITH COR TO IDENTIFY BAS, PACS,

OR SECURITY CABLES.

6. EXISTING TELECOMMUNICATIONS OUTLET. CONTRACTOR SHALL REMOVE ALL DEVICE

FACEPLATES AND MODULAR JACKS. EXISTING OUTLET BOXES AND CONDUITS SHALL

BE PRESERVED FOR REUSE.

7. CONTRACTOR SHALL REMOVE ALL DATA CABLES EXCEPT CATEGORY 6A OR UNLESS

OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE WITH THE COR PRIOR TO

REMOVING CABLES, OUTLETS, FACE PLATES, PATCH PANELS, AND PATCH CABLES.

8. CABLES SHALL NOT BE ABANDONED IN PLACE WITHOUT PRIOR APPROVAL OF THE

COR.

9. WHERE CABLES ARE TO BE REMOVED, CONTRACTOR SHALL COMPLETELY REMOVE

THE CABLE FROM OUTLET TO PATCH PANEL.

10. CONTRACTOR SHALL REMOVE NON-CATEGORY 6/6A FACE PLATES, MODULAR JACKS,

AND PATCH PANELS AFTER CUT OVER TO NEW CATEGORY 6A CABLE PLANT.

11. CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR J-HOOKS, THAT ARE NOT TO BE

REUSED SHALL BE PRESERVED FOR REUSE. COORDINATE WITH THE COR PRIOR TO

REMOVING CABLE SUPPORTS.

12. NURSE CALL SYSTEM TO BE MAINTAINED IN EXISTING LOCATIONS. CONTRACTOR

SHALL COORDINATE NEW EQUIPMENT LOCATION WITH THE COR PRIOR TO MOVING

THE NURSE CALL SYSTEM OR BEFORE WALL DEMOLITION BEGINS.

KEYED NOTES:

1. EXISTING TELECOMMUNICATIONS ROOM. DEMO ALL PATCH PANELS AND CABLING

RELATED TO THE IT/LV PROJECT. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,

ELECTRICAL CABLES AND EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT

DATA RELATED. REMOVE ALL IT RELATED CABLES FROM THE DEVICE TO THE SOURCE.

2. EXISTING CONDITIONS WERE NOT OBSERVED. REMOVE ALL IT DATA CABLES FROM

THE DEVICE TO THE SOURCE.

D.R.

A647

A648

D.R.

A649

Stair 5 S*6*5

A651

A652

A654 A655

A656 A657A658

A659

Elec.

A660

Elec.

A661

Soil. Util.

A662

A663

A663A

A664

A668 A669

A671A

A671

A672

CL. Lin.

A673

HAC

A674

Tlt.

A647A

Tlt.

A649A

Tlt.

A651A

Tlt.

A654A

Tlt.

A655A

Tlt.

A656A

Toilet A659A

Tlt.

A664A

A667A

A670

Tlt.

A675A

Tlt.

A672A

A667

Tlt.

A666

C-6-3A

A658A

A657A

C-6-3A

DNUP

1 2

2 2

2 2

LOW VOLTAGE/ IT

Ross & Baruzzini Inc.

1600 Riveredge Parkway NW Suite 900 Atlanta, GA 30328

Project Number

Building Number

Drawing Number

Drawn By:Checked By:Issue Date:

Location

Project TitlePhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANT

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

100% CONSTRUCTION

DOCUMENTS

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

Scale:

FULLY SPRINKLERED

1/8" = 1'-0"

TD-173-C.1.6

TECHNOLOGY DEMOLITION SIXTH

FLOOR PARTIAL PLAN - D

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST. CINCINNATI, OH. 45220

539-21-701

TL

04-MAY-2022

PR

C1

1/8" = 1'-0"

TECHNOLOGY DEMOLITION SIXTH FLOOR PARTIAL PLAN - D

D B

A

GENERAL NOTES:

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS OTHERWISE NOTED.

3. EXISTING TELECOMMUNICATIONS ROOM OR IT CLOSET. CONTRACTOR SHALL DEMO

ALL PATCH PANELS AND CABLING RELATED TO THIS PROJECT. CONTRACTOR SHALL

REMOVE ALL DATA CABLES FROM THE DEVICE TO THE SOURCE. CONTRACTOR SHALL

COORDINATE WITH THE COR PRIOR TO BEGINNING WORK IN EACH TELECOM ROOM

(TR) OR IT CLOSET.

4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT, ELECTRICAL CABLES AND

EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT DATA RELATED. COORDINATE

WITH COR PRIOR TO REMOVING CABLING FROM WALL FIELDS OR FROM WALL

MOUNTED EQUIPMENT.

5. BUILDING AUTOMATION SYSTEMS (BAS), PACS, AND ELECTRONIC SECURITY SYSTEMS

CABLES SHALL NOT BE REMOVED. COORDINATE WITH COR TO IDENTIFY BAS, PACS,

OR SECURITY CABLES.

6. EXISTING TELECOMMUNICATIONS OUTLET. CONTRACTOR SHALL REMOVE ALL DEVICE

FACEPLATES AND MODULAR JACKS. EXISTING OUTLET BOXES AND CONDUITS SHALL

BE PRESERVED FOR REUSE.

7. CONTRACTOR SHALL REMOVE ALL DATA CABLES EXCEPT CATEGORY 6A OR UNLESS

OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE WITH THE COR PRIOR TO

REMOVING CABLES, OUTLETS, FACE PLATES, PATCH PANELS, AND PATCH CABLES.

8. CABLES SHALL NOT BE ABANDONED IN PLACE WITHOUT PRIOR APPROVAL OF THE

COR.

9. WHERE CABLES ARE TO BE REMOVED, CONTRACTOR SHALL COMPLETELY REMOVE

THE CABLE FROM OUTLET TO PATCH PANEL.

10. CONTRACTOR SHALL REMOVE NON-CATEGORY 6/6A FACE PLATES, MODULAR JACKS,

AND PATCH PANELS AFTER CUT OVER TO NEW CATEGORY 6A CABLE PLANT.

11. CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR J-HOOKS, THAT ARE NOT TO BE

REUSED SHALL BE PRESERVED FOR REUSE. COORDINATE WITH THE COR PRIOR TO

REMOVING CABLE SUPPORTS.

12. NURSE CALL SYSTEM TO BE MAINTAINED IN EXISTING LOCATIONS. CONTRACTOR

SHALL COORDINATE NEW EQUIPMENT LOCATION WITH THE COR PRIOR TO MOVING

THE NURSE CALL SYSTEM OR BEFORE WALL DEMOLITION BEGINS.

KEYED NOTES:

1. EXISTING TELECOMMUNICATIONS ROOM. DEMO ALL PATCH PANELS AND CABLING

RELATED TO THE IT/LV PROJECT. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,

ELECTRICAL CABLES AND EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT

DATA RELATED. REMOVE ALL IT RELATED CABLES FROM THE DEVICE TO THE SOURCE.

2. EXISTING CONDITIONS WERE NOT OBSERVED. REMOVE ALL IT DATA CABLES FROM

THE DEVICE TO THE SOURCE.

A/C Shaft

Bath A711A

Soil. Util.

A712

Tele.

A713

Elec.

A714

S.R.

A715

Clean

Linen A716

S.R.

A717

S.R.

A718

Bed Room A719

Ex. Group A720

Bath A719A

Bed Room A722

Q.R.

A723

T.L.T.

A723A

T.L.T.

A722A

T.L.T.

A715A

Ante A711

Dining/Group

Room A705

Nurse

Station A705A

S.R.

A706

Bath A706A

Bath A707A

T.R.

A707

T.R.

A708

Bath A708A

Bath A709B

Ante A709

Obser.

A710

S.R.

A709A

Exist.

Seclusion A711B

Stair 2 S*7*2

Nurse

Station

Meds A725A

Stor.

A724

Nurse

Station A725

Nurse

Station

Work/Conference A725B

Break

Room A726

Corridor C*7*2

Storage A740

Waiting A774

Office #14 A743

Office #13 A744

Stair 5 S*7*5

Sensory

Therapy

Room A704

Storage A704B

Bath A702A

Interview

Room A702

Nurse Off.

A701

Chief Nurse

Off.

A700

Exam Rm.

A776

Office #18 A775

Reception A773

Training (6) A746 Stor.

A747

S. Office

#11A A748

S. Office

#11A A749

Office #12 A750

Group #2

(10-12) A751Office #10

A752 Tlt.

A753 Office #9

A754 Office #8

A755 Office #7

A756 Office #6

A757

Elec.

A758

Elec.

A759

HAC

A760

Ante A761

Office A762

Office #5 A763

Office #5A A764

Office #5B A765

Group #1

(12-20) A766

Office A767A

Office #2 A768

Office #3 A769

Testing A770

Vis. Bath A771

Copy Rm.

A773A

Staff Office A767

Lockers A727B

Service

Elev. Lobby A727

Laundry A728A

Trash

Chute A727A

Staff Tlt.

A736

Sig. Clos.

A734

Stair 1 S*7*1

HAC

A735

Stor.

A735A

Elec.

A739

Occupational

Therapy A732

Corridor C*7*1

DB Wtr.

A729

Storage A728CSocial

Worker A728D

Group

Room A728

Elec.

A728B

Soc.

Worker A730

O/T Off.

A731

Tlt.

A730A

Social

Worker B733A

Psych. Res.

B734

Tlt.

B734A

Waiting B705

Stat.

B704

Nurse Man.

B703

Soc.

Worker B702

Intake

Coor.

B701

Off.

B733

Off.

B733B

HAC

B732

Stor.

B731

Stor.

B719

Reception B705C

Elec B706

Break

Room B705D

Staff Tlt.

B705E

Signal

Closet B705F

Stair 3 S*7*3

Office B708

Office B709

Office B710

Office B711A

Tobacco &

Acohol

Research

Center B712

Group Rm.

B713

Off.

B714

Off.

B715A

Off.

B716A

Off.

B717

Off.

B715B

Off.

B714A

Off.

B721

Off.

B722

Off.

B723

Off.

B724

Group

Room B725

Off.

B726

Off.

B727

Wash

Room B728

Off.

B729

KLT

B730

Adm. Asst.

B716B

Bath B721A

Tlt.

B723A

Tlt.

B722A

Elec.

B720

Group

Room B725B

Tlt.

B726A

Off.

B711

Tlt.

B729A

Closet A728E

Clos.

A772

Office A741

Office A742

DN UP DNUP

DN UP

DN

UP

LOW VOLTAGE/ IT

Ross & Baruzzini Inc.

1600 Riveredge Parkway NW Suite 900 Atlanta, GA 30328

Project Number

Building Number

Drawing Number

Drawn By:Checked By:Issue Date:

Location

Project TitlePhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANT

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

100% CONSTRUCTION

DOCUMENTS

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

Scale:

FULLY SPRINKLERED

1/16" = 1'-0"

TD-180-C.1.7

TECHNOLOGY DEMOLITION SEVENTH

FLOOR OVERALL PLAN

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST. CINCINNATI, OH. 45220

539-21-701

TL

04-MAY-2022

PR

C1

1/16" = 1'-0"

TECHNOLOGY DEMOLITION SEVENTH FLOOR OVERALL PLAN

GENERAL NOTES:

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS OTHERWISE NOTED.

3. EXISTING TELECOMMUNICATIONS ROOM OR IT CLOSET.

CONTRACTOR SHALL DEMO ALL PATCH PANELS AND CABLING

RELATED TO THIS PROJECT. CONTRACTOR SHALL REMOVE ALL

DATA CABLES FROM THE DEVICE TO THE SOURCE. CONTRACTOR

SHALL COORDINATE WITH THE COR PRIOR TO BEGINNING WORK IN

EACH TELECOM ROOM (TR) OR IT CLOSET.

4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT, ELECTRICAL

CABLES AND EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT

DATA RELATED. COORDINATE WITH COR PRIOR TO REMOVING

CABLING FROM WALL FIELDS OR FROM WALL MOUNTED EQUIPMENT.

5. BUILDING AUTOMATION SYSTEMS (BAS), PACS, AND ELECTRONIC

SECURITY SYSTEMS CABLES SHALL NOT BE REMOVED. COORDINATE

WITH COR TO IDENTIFY BAS, PACS, OR SECURITY CABLES.

6. EXISTING TELECOMMUNICATIONS OUTLET. CONTRACTOR SHALL

REMOVE ALL DEVICE FACEPLATES AND MODULAR JACKS. EXISTING

OUTLET BOXES AND CONDUITS SHALL BE PRESERVED FOR REUSE.

7. CONTRACTOR SHALL REMOVE ALL DATA CABLES EXCEPT CATEGORY

6A OR UNLESS OTHERWISE NOTED. CONTRACTOR SHALL

COORDINATE WITH THE COR PRIOR TO REMOVING CABLES,

OUTLETS, FACE PLATES, PATCH PANELS, AND PATCH CABLES.

8. CABLES SHALL NOT BE ABANDONED IN PLACE WITHOUT PRIOR

APPROVAL OF THE COR.

9. WHERE CABLES ARE TO BE REMOVED, CONTRACTOR SHALL

COMPLETELY REMOVE THE CABLE FROM OUTLET TO PATCH PANEL.

10. CONTRACTOR SHALL REMOVE NON-CATEGORY 6/6A FACE PLATES,

MODULAR JACKS, AND PATCH PANELS AFTER CUT OVER TO NEW

CATEGORY 6A CABLE PLANT.

11. CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR J-HOOKS, THAT ARE

NOT TO BE REUSED SHALL BE PRESERVED FOR REUSE.

COORDINATE WITH THE COR PRIOR TO REMOVING CABLE

SUPPORTS.

12. NURSE CALL SYSTEM TO BE MAINTAINED IN EXISTING LOCATIONS.

CONTRACTOR SHALL COORDINATE NEW EQUIPMENT LOCATION WITH

THE COR PRIOR TO MOVING THE NURSE CALL SYSTEM OR BEFORE

WALL DEMOLITION BEGINS.

KEYED NOTES:

1. EXISTING TELECOMMUNICATIONS ROOM. DEMO ALL PATCH PANELS

AND CABLING RELATED TO THE IT/LV PROJECT. DO NOT REMOVE ANY

WALL MOUNT EQUIPMENT, ELECTRICAL CABLES AND EQUIPMENT, OR

ANY CABLING OR DEVICE THAT IS NOT DATA RELATED. REMOVE ALL

IT RELATED CABLES FROM THE DEVICE TO THE SOURCE. REMOVE

ALL CABLE TRAY ORIGINATING FROM THIS SPACE. TO AFFORD

CEILING SPACE AND ACCOMIDATE PHASING OF NEW PATHWAY

CREATION, PLACE ALL CABLING WITHIN EXISTING CABLE TRAYS IN J-

HOOK SUPPORTS ON EXISTING THREADED ROD SUPPORTS.

D B

A

DB Wtr.

A729

Storage A728CSocial

Worker A728D

Soc.

Worker A730

O/T Off.

Tlt.

A730A

Social

Worker B733A

Psych. Res.

B734

Tlt.

B734A

Waiting B705

Stat.

B704

Nurse Man.

B703

Soc.

Worker B702

Intake

Coor.

B701

Off.

B733

Off.

B733B

HAC

B732

Stor.

B731

Stor.

B719

Reception B705C

Elec B706

Break

Room B705D

Staff Tlt.

B705E

Signal

Closet B705F

Stair 3 S*7*3

Office B708

Office B709

Office B710

Office B711A

Tobacco &

Acohol

Research

Center B712

Group Rm.

B713

Off.

B714

Off.

B715A

Off.

B716A

Off.

B717

Off.

B715B

Off.

B714A

Off.

B721

Off.

B722

Off.

B723

Off.

B724

Group

Room B725

Off.

B726

Off.

B727

Wash

Room B728

Off.

B729

KLT

B730

Adm. Asst.

B716B

Bath B721A

Tlt.

B723A

Tlt.

B722A

Elec.

B720

Group

Room B725B

Tlt.

B726A

Off.

B711

Tlt.

B729A

DN

UP

1 333

1 1

4 4

4 3 3

3 4

LOW VOLTAGE/ IT

Ross & Baruzzini Inc.

1600 Riveredge Parkway NW Suite 900 Atlanta, GA 30328

Project Number

Building Number

Drawing Number

Drawn By:Checked By:Issue Date:

Location

Project TitlePhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANT

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

100% CONSTRUCTION

DOCUMENTS

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

Scale:

FULLY SPRINKLERED

1/8" = 1'-0"

TD-181-C.1.7

TECHNOLOGY DEMOLITION SEVENTH

FLOOR PARTIAL PLAN - A

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST. CINCINNATI, OH. 45220

539-21-701

TL

04-MAY-2022

PR

C1

1/8" = 1'-0"

TECHNOLOGY DEMOLITION SEVENTH FLOOR PARTIAL PLAN - A

D B

A

GENERAL NOTES:

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS OTHERWISE NOTED.

3. EXISTING TELECOMMUNICATIONS ROOM OR IT CLOSET. CONTRACTOR SHALL DEMO

ALL PATCH PANELS AND CABLING RELATED TO THIS PROJECT. CONTRACTOR SHALL

REMOVE ALL DATA CABLES FROM THE DEVICE TO THE SOURCE. CONTRACTOR SHALL

COORDINATE WITH THE COR PRIOR TO BEGINNING WORK IN EACH TELECOM ROOM

(TR) OR IT CLOSET.

4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT, ELECTRICAL CABLES AND

EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT DATA RELATED. COORDINATE

WITH COR PRIOR TO REMOVING CABLING FROM WALL FIELDS OR FROM WALL

MOUNTED EQUIPMENT.

5. BUILDING AUTOMATION SYSTEMS (BAS), PACS, AND ELECTRONIC SECURITY SYSTEMS

CABLES SHALL NOT BE REMOVED. COORDINATE WITH COR TO IDENTIFY BAS, PACS,

OR SECURITY CABLES.

6. EXISTING TELECOMMUNICATIONS OUTLET. CONTRACTOR SHALL REMOVE ALL DEVICE

FACEPLATES AND MODULAR JACKS. EXISTING OUTLET BOXES AND CONDUITS SHALL

BE PRESERVED FOR REUSE.

7. CONTRACTOR SHALL REMOVE ALL DATA CABLES EXCEPT CATEGORY 6A OR UNLESS

OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE WITH THE COR PRIOR TO

REMOVING CABLES, OUTLETS, FACE PLATES, PATCH PANELS, AND PATCH CABLES.

8. CABLES SHALL NOT BE ABANDONED IN PLACE WITHOUT PRIOR APPROVAL OF THE

COR.

9. WHERE CABLES ARE TO BE REMOVED, CONTRACTOR SHALL COMPLETELY REMOVE

THE CABLE FROM OUTLET TO PATCH PANEL.

10. CONTRACTOR SHALL REMOVE NON-CATEGORY 6/6A FACE PLATES, MODULAR JACKS,

AND PATCH PANELS AFTER CUT OVER TO NEW CATEGORY 6A CABLE PLANT.

11. CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR J-HOOKS, THAT ARE NOT TO BE

REUSED SHALL BE PRESERVED FOR REUSE. COORDINATE WITH THE COR PRIOR TO

REMOVING CABLE SUPPORTS.

12. NURSE CALL SYSTEM TO BE MAINTAINED IN EXISTING LOCATIONS. CONTRACTOR

SHALL COORDINATE NEW EQUIPMENT LOCATION WITH THE COR PRIOR TO MOVING

THE NURSE CALL SYSTEM OR BEFORE WALL DEMOLITION BEGINS.

KEYED NOTES:

1. EXISTING TELECOMMUNICATIONS ROOM. DEMO ALL PATCH PANELS AND CABLING

RELATED TO THE IT/LV PROJECT. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,

ELECTRICAL CABLES AND EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT

DATA RELATED. REMOVE ALL IT RELATED CABLES FROM THE DEVICE TO THE SOURCE.

2. EXISTING CONDITIONS WERE NOT OBSERVED. REMOVE ALL IT DATA CABLES FROM

THE DEVICE TO THE SOURCE.

A/C Shaft A/C Shaft

Bath A711A

Soil. Util.

A712

Tele.

A713

Elec.

A714

S.R.

A715

Clean

Linen A716

S.R.

A717

S.R.

A718

Bed Room A719

Ex. Group A720

Bath A719A

Bed Room A722

Q.R.

A723

T.L.T.

A723A

T.L.T.

A722A

T.L.T.

A715A

Ante A711

Dining/Group

Room A705

Nurse

Station A705A

S.R.

A706

Bath A706A

Bath A707A

T.R.

A707

T.R.

A708

Bath A708A

Bath A709B

Ante A709

Obser.

A710

S.R.

A709A

Exist.

Seclusion A711B

Stair 2 S*7*2

Nurse

Station

Meds A725A

Stor.

A724

Nurse

Station A725

Nurse

Station

Work/Conference A725B

Break

Room A726

Corridor C*7*2

Storage A740

Waiting A774

Sensory

Therapy

Room A704

Storage A704B

Bath A702A

Interview

Room A702

Nurse Off.

A701

Chief Nurse

Off.

A700

Exam Rm.

A776

Office #18 A775

Office A767A

Office #2 A768

Office #3 A769

Testing A770

Copy Rm.

A773A

Staff Office

Lockers A727B

Service

Elev. Lobby A727

Laundry A728A

Trash

Chute A727A

Staff Tlt.

A736

Sig. Clos.

A734

Stair 1 S*7*1

HAC

A735

Stor.

A735A

Elec.

A739

Occupational

Therapy A732

Corridor C*7*1

Group

Room A728

Elec.

A728B

O/T Off.

A731

Closet A728E

DN UP

DN UP

3 3 3

4 1

3 3

3 4

2 2

2 2

2 2

2 2

LOW VOLTAGE/ IT

Ross & Baruzzini Inc.

1600 Riveredge Parkway NW Suite 900 Atlanta, GA 30328

Project Number

Building Number

Drawing Number

Drawn By:Checked By:Issue Date:

Location

Project TitlePhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANT

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

100% CONSTRUCTION

DOCUMENTS

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

Scale:

FULLY SPRINKLERED

1/8" = 1'-0"

TD-182-C.1.7

TECHNOLOGY DEMOLITION SEVENTH

FLOOR PARTIAL PLAN - B

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST. CINCINNATI, OH. 45220

539-21-701

TL

04-MAY-2022

PR

C1

1/8" = 1'-0"

TECHNOLOGY DEMOLITION SEVENTH FLOOR PARTIAL PLAN - B

D B

A

GENERAL NOTES:

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS OTHERWISE NOTED.

3. EXISTING TELECOMMUNICATIONS ROOM OR IT CLOSET. CONTRACTOR SHALL DEMO

ALL PATCH PANELS AND CABLING RELATED TO THIS PROJECT. CONTRACTOR SHALL

REMOVE ALL DATA CABLES FROM THE DEVICE TO THE SOURCE. CONTRACTOR SHALL

COORDINATE WITH THE COR PRIOR TO BEGINNING WORK IN EACH TELECOM ROOM

(TR) OR IT CLOSET.

4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT, ELECTRICAL CABLES AND

EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT DATA RELATED. COORDINATE

WITH COR PRIOR TO REMOVING CABLING FROM WALL FIELDS OR FROM WALL

MOUNTED EQUIPMENT.

5. BUILDING AUTOMATION SYSTEMS (BAS), PACS, AND ELECTRONIC SECURITY SYSTEMS

CABLES SHALL NOT BE REMOVED. COORDINATE WITH COR TO IDENTIFY BAS, PACS,

OR SECURITY CABLES.

6. EXISTING TELECOMMUNICATIONS OUTLET. CONTRACTOR SHALL REMOVE ALL DEVICE

FACEPLATES AND MODULAR JACKS. EXISTING OUTLET BOXES AND CONDUITS SHALL

BE PRESERVED FOR REUSE.

7. CONTRACTOR SHALL REMOVE ALL DATA CABLES EXCEPT CATEGORY 6A OR UNLESS

OTHERWISE NOTED. CONTRACTOR SHALL COORDINATE WITH THE COR PRIOR TO

REMOVING CABLES, OUTLETS, FACE PLATES, PATCH PANELS, AND PATCH CABLES.

8. CABLES SHALL NOT BE ABANDONED IN PLACE WITHOUT PRIOR APPROVAL OF THE

COR.

9. WHERE CABLES ARE TO BE REMOVED, CONTRACTOR SHALL COMPLETELY REMOVE

THE CABLE FROM OUTLET TO PATCH PANEL.

10. CONTRACTOR SHALL REMOVE NON-CATEGORY 6/6A FACE PLATES, MODULAR JACKS,

AND PATCH PANELS AFTER CUT OVER TO NEW CATEGORY 6A CABLE PLANT.

11. CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR J-HOOKS, THAT ARE NOT TO BE

REUSED SHALL BE PRESERVED FOR REUSE. COORDINATE WITH THE COR PRIOR TO

REMOVING CABLE SUPPORTS.

12. NURSE CALL SYSTEM TO BE MAINTAINED IN EXISTING LOCATIONS. CONTRACTOR

SHALL COORDINATE NEW EQUIPMENT LOCATION WITH THE COR PRIOR TO MOVING

THE NURSE CALL SYSTEM OR BEFORE WALL DEMOLITION BEGINS.

KEYED NOTES:

1. EXISTING TELECOMMUNICATIONS ROOM. DEMO ALL PATCH PANELS AND CABLING

RELATED TO THE IT/LV PROJECT. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,

ELECTRICAL CABLES AND EQUIPMENT, OR ANY CABLING OR DEVICE THAT IS NOT

DATA RELATED. REMOVE ALL IT RELATED CABLES FROM THE DEVICE TO THE SOURCE.

2. EXISTING CONDITIONS WERE NOT OBSERVED. REMOVE ALL IT DATA CABLES FROM

THE DEVICE TO THE SOURCE.

Waiting Office #14 A743

Office #13 A744

Stair 5 S*7*5

Reception A773

Training (6) A746 Stor.

A747

S. Office

#11A A748

S. Office

#11A A749

Office #12 A750

Group…

This is the start of the file's text. The full file is on GovTribe.