ATTACHMENT 4 - Drawings 3 of 13.pdf

PDF 11 MB Posted

Attached to
36C77623B0005 EHRM Infrastructure Upgrades - Cincinnati Project #539-21-701
Solicitation number
36C77623B0005
Issued by

About this file

This document provides details on a federal solicitation opportunity and a related file attachment. The solicitation number is 36C77623B0005 for the EHRM Infrastructure Upgrades - Cincinnati Project #539-21-701 opportunity. The Department of Veterans Affairs Technology Acquisition Center Austin is seeking construction services for infrastructure upgrades at the Cincinnati VAMC, as described in the related drawing attachment file. The solicitation type is for construction of the specified upgrades at the medical center.

View the file

Other files

File Type Posted
36C77623B0005 0004 - Extension 3-10-23.pdf PDF
Technical Questions and Answers - Cincinnati EHRM.pdf PDF
36C77623B0005 0003.pdf PDF
36C77623B0005 0002 - EHRM Infrastructure Upgrades - Cincinnati.pdf PDF
Site Visit Sign-In Sheet - 36C77632B0005 EHRM Infrastructure Construction - Cincinnati VAMC.pdf PDF
ATTACHMENT 24 - Construction Wage Rates - Hamilton 01-13-2023.pdf PDF
36C77623B0005 0001 - EHRM Infrastructure Upgrades - Cincinnati.pdf PDF
Site Visit Memorandum.pdf PDF
ATTACHMENT 23 - Contractor Safety - Environmental Form.pdf PDF
ATTACHMENT 6 - Drawings 5 of 13.pdf PDF
ATTACHMENT 18 - Technology Narrative.pdf PDF
ATTACHMENT 13 - Drawings 12 of 13.pdf PDF
ATTACHMENT 15 - Plumbing Narrative.pdf PDF
ATTACHMENT 19 - Hazardous Materials Inspection Report.pdf PDF
ATTACHMENT 24 - Construction Wage Rates - Hamilton 1-13-2022.pdf PDF
ATTACHMENT 21 - COVID-19 Safety Protocols 12-14-21.pdf PDF
ATTACHMENT 14 - Drawings 13 of 13.pdf PDF
ATTACHMENT 20 - Brand Name Justification.pdf PDF
ATTACHMENT 22 - Limitations on Subcontracting - Nov 2022.pdf PDF
ATTACHMENT 9 - Drawings 8 of 13.pdf PDF
ATTACHMENT 10 - Drawings 9 of 13.pdf PDF
ATTACHMENT 16 - Mechanical Narrative.pdf PDF
ATTACHMENT 7 - Drawings 6 of 13.pdf PDF
ATTACHMENT 3 - Drawings 2 of 13.pdf PDF
ATTACHMENT 17 - Electrical Narrative.pdf PDF
ATTACHMENT 2 - Drawings 1 of 13.pdf PDF
ATTACHMENT 25 - Site Visit Instructions.pdf PDF
ATTACHMENT 8 - Drawings 7 of 13.pdf PDF
ATTACHMENT 11 - Drawings 10 of 13.pdf PDF
ATTACHMENT 12 - Drawings 11 of 13.pdf PDF
ATTACHMENT 5 - Drawings 4 of 13.pdf PDF
36C77623B0005 Solicitation - Cincinnati EHRM.pdf PDF
ATTACHMENT 1 - Specifications.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

UP

EXIST.

TELECOM ROOM

B312D

EXIST.

RESEARCH OFFICE

B312

EXIST.

OFFICE

B312A

EXIST.

STAIR 3

B*3*3

14'-0"±

'-1

/4

TELECOM

ROOM

C3006

EXIST.

CONSULTATION

C3005

EXIST.

LOBBY

C3001

EXIST.

POST OP

C3040

EXIST.

PREP./RECOVERY

C3039

EXIST.

STAFF WORKRM.

C3007

EXIST.

RECEPTION

C3004

EXIST.

CORRIDOR

C*3*11

15'-9 1/2"±

6' -6

2'-6"

5'-8"

EXIST.

FAMILY WAITING

C310

EXIST.

LACTATION

C312

EXIST.

GRIEVE CONSULT.

C313

EXIST.

SOCIAL WORKER

A383

EXIST.

STORAGE

C308

EXIST.

ON CALL

A381

EXIST.

CORRIDOR

C*3*17

1717B312 B312D

C3006

A383A

1 EXISTING TELECOM ROOM B312D - ROOM RENOVATION

SCALE: 1/4" = 1'-0" 3 TELECOM ROOM C3006 - ROOM RENOVATION

SCALE: 1/4" = 1'-0"

5 RESIDENT OFFICE/OVERNIGHT A383A- ROOM RENOVATION

SCALE: 1/4" = 1'-0"

X2

X2

X2

X4

X2 X2

X2

RESIDENT OFFICE/

OVERNIGHT

A383A

1 2532

'-6

12'-4"±

16'-4 3/8"±

6' -2

/4

X2

X2A

X4

X2

X4

7 TELECOM ROOM C305 - ROOM RENOVATION

SCALE: 1/4" = 1'-0"

TELECOM

ROOM

C305

EXIST.

OFFICE

C306

EXIST.

CORRIDOR

C*3*17

C305

8'-4"±

'-9

2 3

X2

X4

X2

X4

X4

EXIST.

TELECOM ROOM

B312D

EXIST.

RESEARCH OFFICE

B312

EXIST.

OFFICE

B312A

EXIST.

STAIR 3

B*3*3

EXIST.

CONSULTATION

C3005

EXIST.

LOBBY

C3001

EXIST.

POST OP

C3040

EXIST.

PREP./RECOVERY

C3039

EXIST.

STAFF WORKRM.

C3007

EXIST.

RECEPTION

C3004

EXIST.

CORRIDOR

C*3*11

EXIST.

FAMILY WAITING

C310

EXIST.

LACTATION

C312

EXIST.

GRIEVE CONSULT.

C313

EXIST.

SOCIAL WORKER

A383

EXIST.

STORAGE

C308

EXIST.

ON CALL

A381

EXIST.

CORRIDOR

C*3*17

TELECOM

ROOM

C3006

2 EXISTING TELECOM ROOM B312D - CEILING RENOVATION

SCALE: 1/4" = 1'-0" 4 TELECOM ROOM C3006 - CEILING RENOVATION

SCALE: 1/4" = 1'-0"

6 RESIDENT OFFICE/OVERNIGHT A383A - CEILING RENOVATION

SCALE: 1/4" = 1'-0"

OD

OD

RESIDENT OFFICE/

OVERNIGHT

A383A

8 TELECOM ROOM C305 - CEILING RENOVATION

SCALE: 1/4" = 1'-0"

TELECOM

ROOM

C305 EXIST.

OFFICE

C306

EXIST.

CORRIDOR

C*3*17

OD

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANTRevisions: Date:

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

FULLY SPRINKLERED

539-21-701

4-MAY-2022

100% CONSTRUCTION

DOCUMENTS

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST., CINCINNATI, OH

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

ETS

T

TA

GE

S

R I

E T E X

FO

T

CE

TI

H

AS

DER CRA

F. BIAN

C

OJO

SE

P

H

7 6 22 1

5/4/22

AS-403-C.1.3

ENLARGED FLOOR PLANS -

3RD FLOOR RENOVATION

IAR

C1

1. REFERENCE GENERAL NOTES ON SHEET GI-004.

2. UNLESS NOTED OTHERWISE, ALL EXISTING WALLS

ARE 5/8" GYPSUM BOARD/3 5/8"METAL STUD FRAMED

TO UNDERSIDE OF PRIMARY BUILDING FRAMING

STRUCTURE (1 HR. FIRE RATED - CONSTRUCTION

SIMILAR TO U.l. DESIGN NO. U465). CONTRACTOR TO

VERIFY.

3. UNLESS NOTED OTHERWISE, ALL EXISTING DOOR

ASSEMBLIES ARE SOLID CORE WOOD DOORS/HOLLOW

METAL FRAME TYPICAL (3'-0" X 7'-0").

4. UNLESS NOTED OTHERWISE ALL EXISTING LAY-IN

CEILING ASSEMBLIES ARE 2' X 2' STANDARD GRID WITH

FISSURED TILES AT 8'-0" A.F.F. TYPICAL.

5. UNLESS NOTED OTHERWISE, ALL EXISTING STEEL

COLUMN FUR-OUTS ARE GYPSUM BOARD/METAL STUD

FRAMED TYPICAL.

6. PARTIAL OR ENTIRE RECONSTRUCTION OF SOME

EXISTING CEILING ASSEMBLIES THOUGH OUT THE

ENTIRE BUILDING(S), ESPECIALLY IN CORRIDORS,

WILL BE NECESSARY. REFERENCE ALL DISCIPLINE

DEMOLITION DRAWINGS. RECONSTRUCTION IS TO

INCLUDE MISCELLANEOUS PATCHING /REPAIR TO

MATCH EXISTING OR BETTER CONDITIONS.

7. EXISTING FIRE-RATED WALL IDENTIFICATION

INDICATED ONLY FOR IMMEDIATE AFFECTED ROOM

WALLS. CONTRACTOR SHALL VERIFY FULL EXTENT OF

EXISTING FIRE-RATED WALLS AT ADJACENT AREAS.

8. ALL NEW WALLS SHALL BE PARTITION TYPE '1' UNLESS

OTHERWISE NOTED.

9. UNLESS NOTED OTHERWISE AT ALL ROOMS WHERE

EXISTING LAY-IN CEILING IS REMOVED AND IS TO

BECOME A "NO CEILING" ROOM, THE EXISTING

GYPSUM BOARD ABOVE PREVIOUSLY REMOVED

CEILING IS TO BE FULLY TAPED, FLOATED, TEXTURED

AND PAINTED TO MATCH EXISTING WALLS.

GENERAL NOTES - RENOVATION

1. EXISTING DOOR/FRAME ASSEMBLY TO REMAIN.

2. PROVIDE CARD READER.

3. PROVIDE ROOM SIGNAGE.

4. PROVIDE NEW FLOORING AND BASE AS SCHEDULED.

5. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE IN THIS ROOM THAT MAY REQUIRE MINOR

DEMOLITION, PATCHING AND REPAIR OF EXISTING

FLOOR SUBSTRATE, WALL OR MISCELLANEOUS

ASSEMBLIES.

6. PROVIDE 8'x4'x3/4" 'AC' FACED FIRE-RATED PLYWOOD

VERTICALLY ON ALL WALLS AS INDICATED. PAINT WITH 2

COATS MIN. FIRE-RATED PAINT. COORDINATE EXACT

LOCATION A.F.F. WITH TECHNOLOGY AND ELECTRICAL

DRAWINGS AND EXISTING CONDITIONS.

7. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE OF EXISTING AND NEW COMPONENTS AT

CEILING LEVEL.

8. EXISTING FLOOR AND BASE TO REMAIN. REPAIR AS

NECESSARY TO MATCH EXISTING CONDITIONS OR

BETTER.

9. EXISTING VCT FLOORING AND RUBBER BASE TO REMAIN.

10. LIMITED RENOVATION TO EXISTING CEILING ASSEMBLY

PER MEP AND TECHNOLOGY DRAWINGS WORK SCOPE.

11. RELOCATED EXISTING MARKER BOARD.

12. RELOCATED EXISTING MILLWORK.

13. CEILING FUR-DOWN ABOVE.

14. NEW GYPSUM BOARD/METAL STUD FRAMED FUR-DOWN

TO MATCH EXISTING HEIGHT. NO JOINTS

UNLESS NOTED OTHERWISE.

15. RELOCATED EXISTING LIGHT FIXTURE.

16. RELOCATED EXISTING TV MONITOR.

17. EXISTING ALUMINUM FLOOR AND WALL (EACH SIDE)

EXPANSION JOINT COVERS TO REMAIN.

18. EXISTING GYPSUM BOARD/METAL STUD FRAMED

FUR-DOWN TO REMAIN.

19. RELOCATED EXISTING FIRE EXTINGUISHER.

20. EXISTING EXTERIOR WINDOW TO REMAIN.

21. REINSTALL EXISTING SALVAGED WOOD BASE AND CHAIR

RAIL. PROVIDE BALANCE OF MATERIAL AS NEEDED TO

COMPLETE JOB. PAINT ALL BASE AND CHAIR RAIL IN

ENTIRE ROOM.

22. EXISTING PLASTER ON CMU TO UNDERSIDE OF EXISTING

STRUCTURE (4" OR 8" CMU PER WALL THICKNESS

DEPICTED GRAPHICALLY). FIRE-RATED WALL.

CONTRACTOR VERIFY.

23. EXISTING ROOM SIGNAGE.

24. EXISTING CARD READER.

25. REFERENCE DOOR SCHEDULE.

26. PAINT INTERIOR SIDE OF EXISTING WINDOW GLAZING

ONLY "FLAT BLACK".

27. REINSTALLED EXISTING ROOM SIGNAGE.

28. REINSTALLED EXISTING CARD READER.

29. PLASTER ASSEMBLY INFILL AT EXISTING WALL AS

DETAILED AT EXISTING WINDOW OPENING.

30. ENSURE EXISTING WALL VENT IS SECURELY CLOSED

SHUT PRIOR TO COVER-UP.

31. PROVIDE WALL PROTECTION TO MATCH EXISTING.

32. PROVIDE NEW CEILING AS SCHEDULED.

33. PROVIDE GYPSUM BOARD/STEEL STUD FRAMED

FUR-DOWN AS DETAILED.

34. PROVIDE 2' X 2' RAISED FLOOR SYSTEM AT 10" ABOVE

THE 4TH FLOOR LEVEL.

35. ELECTRICAL CONDUITS AND MECHANICAL PIPING PER

MEP DRAWINGS.

36. PROVIDE 5/8" GYPSUM BOARD WHERE EXISTING TILE

WAINSCOT AND SUBSTRATE WAS REMOVED. TEXTURE

AND FINISH TO MATCH EXISTING ADJACENT WALLS (4'-0"±

HIGH, LOCATE AS INDICATED BY HEAVY LINE).

37. TEXTURE AND FINISH EXISTING GYPSUM BOARD

SUBSTRATE TO MATCH EXISTING ADJACENT WALLS.

38. GYPSUM BOARD ASSEMBLY INFILL AS DETAILED AT

EXISTING WINDOW OPENING.

39. PROVIDE INFILL PER KEYED NOTE 29 AT VOID LEFT BY

HEATER REMOVED.

40. PROVIDE 1" THICK MINIMUM CONCRETE INFILL FLUSH

WITH EXISTING CONCRETE TOPPING WHERE PORTIONS

OF EXISTING CMU WALLS ARE REMOVED.

41. PROVIDE PAINTED WOOD CHAIR RAIL TO MATCH

EXISTING.

42. REINSTALLED EXISTING SHELF.

43. PROVIDE GYPSUM BOARD/METAL STUD FRAMED CHASE

FROM FLOORS ABOVE . MINIMIZE SIZE AND REFERENCE

MEP DRAWINGS FOR COMPONENTS TO BE IN CHASE.

44. RAMP AND RAILS BY RAISED FLOOR SYSTEM

MANUFACTURER.

45. ROOM PERIMETER WALLS TO BE FULLY SEALED TOP

AND BOTTOM ON BOTH SIDES OF WALL. EXTERIOR WALL

SEAL INTERIOR SIDE ONLY.

KEYED NOTES - RENOVATION

46. TEMPORARY ALUMINUM RAMP BY CONTRACTOR TO BE

RETURNED TO OWNER AT END OF JOB.

47. MODULAR BRICK INFILL ON EXTERIOR TO MATCH

EXISTING. TOOTH-IN AND MATCH MORTAR.

KEYED NOTES - RENOVATION (CONT.)

EXISTING WALL TO REMAIN

NEW WALL CONSTRUCTION

EXISTING DOOR/FRAME ASSEMBLY

TO REMAIN

EXISTING WINDOW ASSEMBLY

TO REMAIN

NEW WINDOW ASSEMBLY

NEW DOOR/FRAME ASSEMBLY

1 HR. FIRE-RATED WALL (EXISTING)

2 HR. FIRE-RATED WALL (EXISTING)

LEGEND - RENOVATION

FIRE-RATED WALL (NEW OR EXISTING

1 HOUR UNLESS NOTED OTHERWISE)

TRUE NORTH PLAN

NORTH

TRUE NORTH PLAN

NORTH

TRUE NORTH PLAN

NORTH

TRUE NORTH PLAN

NORTH

TRUE NORTH PLAN

NORTH

TRUE NORTH PLAN

NORTH

TRUE NORTH PLAN

NORTHTRUE NORTH PLAN

NORTH

1 TELECOM ROOM A441 - ROOM RENOVATION

SCALE: 1/4" = 1'-0"

3 EXIST. COMPUTER A437C - ROOM RENOVATION

SCALE: 1/4" = 1'-0"

A437A

A437

A437C

15'-4"±

9' -1

2 23

A441

TELECOM

ROOM

A441

EXIST. IRM

NOC

A437

EXIST. CPU

ROOM

A437C

EXIST. SERVICE

LOBBY

A436

3'-2 1/2"

7' -0

X3B X3B

X3B X3B

'-6

13'-8"±

'-1

1"

3'-3"

17'-7 1/4"±

10'-0" (1/12 RAMP SLOPE)

4444 5

X4 X2A

X2A

X2A

X2A

X2

X2

2 28

2 TELECOM ROOM A441 - CEILING RENOVATION

SCALE: 1/4" = 1'-0"

4 EXIST. COMPUTER A437C - CEILING RENOVATION

SCALE: 1/4" = 1'-0"

OD 77

TELECOM

ROOM

A441

EXIST. IRM

NOC

A437

EXIST. CPU

ROOM

A437C

EXIST. SERVICE

LOBBY

A436

OD OD

OD

OD OD

OD

OD

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANTRevisions: Date:

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

FULLY SPRINKLERED

539-21-701

4-MAY-2022

100% CONSTRUCTION

DOCUMENTS

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST., CINCINNATI, OH

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

ETS

T

TA

GE

S

R I

E T E X

FO

T

CE

TI

H

AS

DER CRA

F. BIAN

C

OJ

O

SE

P

H

7 6 22 1

5/4/22

AS-404-C.1.4

ENLARGED FLOOR PLANS -

FOURTH FLOOR - RENOVATION

IAR

IAR, JFB

1. REFERENCE GENERAL NOTES ON SHEET GI-004.

2. UNLESS NOTED OTHERWISE, ALL EXISTING WALLS

ARE 5/8" GYPSUM BOARD/3 5/8"METAL STUD FRAMED

TO UNDERSIDE OF PRIMARY BUILDING FRAMING

STRUCTURE (1 HR. FIRE RATED - CONSTRUCTION

SIMILAR TO U.l. DESIGN NO. U465). CONTRACTOR TO

VERIFY.

3. UNLESS NOTED OTHERWISE, ALL EXISTING DOOR

ASSEMBLIES ARE SOLID CORE WOOD DOORS/HOLLOW

METAL FRAME TYPICAL (3'-0" X 7'-0").

4. UNLESS NOTED OTHERWISE ALL EXISTING LAY-IN

CEILING ASSEMBLIES ARE 2' X 2' STANDARD GRID WITH

FISSURED TILES AT 8'-0" A.F.F. TYPICAL.

5. UNLESS NOTED OTHERWISE, ALL EXISTING STEEL

COLUMN FUR-OUTS ARE GYPSUM BOARD/METAL STUD

FRAMED TYPICAL.

6. PARTIAL OR ENTIRE RECONSTRUCTION OF SOME

EXISTING CEILING ASSEMBLIES THOUGH OUT THE

ENTIRE BUILDING(S), ESPECIALLY IN CORRIDORS,

WILL BE NECESSARY. REFERENCE ALL DISCIPLINE

DEMOLITION DRAWINGS. RECONSTRUCTION IS TO

INCLUDE MISCELLANEOUS PATCHING /REPAIR TO

MATCH EXISTING OR BETTER CONDITIONS.

7. EXISTING FIRE-RATED WALL IDENTIFICATION

INDICATED ONLY FOR IMMEDIATE AFFECTED ROOM

WALLS. CONTRACTOR SHALL VERIFY FULL EXTENT OF

EXISTING FIRE-RATED WALLS AT ADJACENT AREAS.

8. ALL NEW WALLS SHALL BE PARTITION TYPE '1' UNLESS

OTHERWISE NOTED.

9. UNLESS NOTED OTHERWISE AT ALL ROOMS WHERE

EXISTING LAY-IN CEILING IS REMOVED AND IS TO

BECOME A "NO CEILING" ROOM, THE EXISTING

GYPSUM BOARD ABOVE PREVIOUSLY REMOVED

CEILING IS TO BE FULLY TAPED, FLOATED, TEXTURED

AND PAINTED TO MATCH EXISTING WALLS.

GENERAL NOTES - RENOVATION

1. EXISTING DOOR/FRAME ASSEMBLY TO REMAIN.

2. PROVIDE CARD READER.

3. PROVIDE ROOM SIGNAGE.

4. PROVIDE NEW FLOORING AND BASE AS SCHEDULED.

5. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE IN THIS ROOM THAT MAY REQUIRE MINOR

DEMOLITION, PATCHING AND REPAIR OF EXISTING

FLOOR SUBSTRATE, WALL OR MISCELLANEOUS

ASSEMBLIES.

6. PROVIDE 8'x4'x3/4" 'AC' FACED FIRE-RATED PLYWOOD

VERTICALLY ON ALL WALLS AS INDICATED. PAINT WITH 2

COATS MIN. FIRE-RATED PAINT. COORDINATE EXACT

LOCATION A.F.F. WITH TECHNOLOGY AND ELECTRICAL

DRAWINGS AND EXISTING CONDITIONS.

7. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE OF EXISTING AND NEW COMPONENTS AT

CEILING LEVEL.

8. EXISTING FLOOR AND BASE TO REMAIN. REPAIR AS

NECESSARY TO MATCH EXISTING CONDITIONS OR

BETTER.

9. EXISTING VCT FLOORING AND RUBBER BASE TO REMAIN.

10. LIMITED RENOVATION TO EXISTING CEILING ASSEMBLY

PER MEP AND TECHNOLOGY DRAWINGS WORK SCOPE.

11. RELOCATED EXISTING MARKER BOARD.

12. RELOCATED EXISTING MILLWORK.

13. CEILING FUR-DOWN ABOVE.

14. NEW GYPSUM BOARD/METAL STUD FRAMED FUR-DOWN

TO MATCH EXISTING HEIGHT. NO JOINTS

UNLESS NOTED OTHERWISE.

15. RELOCATED EXISTING LIGHT FIXTURE.

16. RELOCATED EXISTING TV MONITOR.

17. EXISTING ALUMINUM FLOOR AND WALL (EACH SIDE)

EXPANSION JOINT COVERS TO REMAIN.

18. EXISTING GYPSUM BOARD/METAL STUD FRAMED

FUR-DOWN TO REMAIN.

19. RELOCATED EXISTING FIRE EXTINGUISHER.

20. EXISTING EXTERIOR WINDOW TO REMAIN.

21. REINSTALL EXISTING SALVAGED WOOD BASE AND CHAIR

RAIL. PROVIDE BALANCE OF MATERIAL AS NEEDED TO

COMPLETE JOB. PAINT ALL BASE AND CHAIR RAIL IN

ENTIRE ROOM.

22. EXISTING PLASTER ON CMU TO UNDERSIDE OF EXISTING

STRUCTURE (4" OR 8" CMU PER WALL THICKNESS

DEPICTED GRAPHICALLY). FIRE-RATED WALL.

CONTRACTOR VERIFY.

23. EXISTING ROOM SIGNAGE.

24. EXISTING CARD READER.

25. REFERENCE DOOR SCHEDULE.

26. PAINT INTERIOR SIDE OF EXISTING WINDOW GLAZING

ONLY "FLAT BLACK".

27. REINSTALLED EXISTING ROOM SIGNAGE.

28. REINSTALLED EXISTING CARD READER.

29. PLASTER ASSEMBLY INFILL AT EXISTING WALL AS

DETAILED AT EXISTING WINDOW OPENING.

30. ENSURE EXISTING WALL VENT IS SECURELY CLOSED

SHUT PRIOR TO COVER-UP.

31. PROVIDE WALL PROTECTION TO MATCH EXISTING.

32. PROVIDE NEW CEILING AS SCHEDULED.

33. PROVIDE GYPSUM BOARD/STEEL STUD FRAMED

FUR-DOWN AS DETAILED.

34. PROVIDE 2' X 2' RAISED FLOOR SYSTEM AT 10" ABOVE

THE 4TH FLOOR LEVEL.

35. ELECTRICAL CONDUITS AND MECHANICAL PIPING PER

MEP DRAWINGS.

36. PROVIDE 5/8" GYPSUM BOARD WHERE EXISTING TILE

WAINSCOT AND SUBSTRATE WAS REMOVED. TEXTURE

AND FINISH TO MATCH EXISTING ADJACENT WALLS (4'-0"±

HIGH, LOCATE AS INDICATED BY HEAVY LINE).

37. TEXTURE AND FINISH EXISTING GYPSUM BOARD

SUBSTRATE TO MATCH EXISTING ADJACENT WALLS.

38. GYPSUM BOARD ASSEMBLY INFILL AS DETAILED AT

EXISTING WINDOW OPENING.

39. PROVIDE INFILL PER KEYED NOTE 29 AT VOID LEFT BY

HEATER REMOVED.

40. PROVIDE 1" THICK MINIMUM CONCRETE INFILL FLUSH

WITH EXISTING CONCRETE TOPPING WHERE PORTIONS

OF EXISTING CMU WALLS ARE REMOVED.

41. PROVIDE PAINTED WOOD CHAIR RAIL TO MATCH

EXISTING.

42. REINSTALLED EXISTING SHELF.

43. PROVIDE GYPSUM BOARD/METAL STUD FRAMED CHASE

FROM FLOORS ABOVE . MINIMIZE SIZE AND REFERENCE

MEP DRAWINGS FOR COMPONENTS TO BE IN CHASE.

44. RAMP AND RAILS BY RAISED FLOOR SYSTEM

MANUFACTURER.

45. ROOM PERIMETER WALLS TO BE FULLY SEALED TOP

AND BOTTOM ON BOTH SIDES OF WALL. EXTERIOR WALL

SEAL INTERIOR SIDE ONLY.

KEYED NOTES - RENOVATION

46. TEMPORARY ALUMINUM RAMP BY CONTRACTOR TO BE

RETURNED TO OWNER AT END OF JOB.

47. MODULAR BRICK INFILL ON EXTERIOR TO MATCH

EXISTING. TOOTH-IN AND MATCH MORTAR.

KEYED NOTES - RENOVATION (CONT.)

EXISTING WALL TO REMAIN

NEW WALL CONSTRUCTION

EXISTING DOOR/FRAME ASSEMBLY

TO REMAIN

EXISTING WINDOW ASSEMBLY

TO REMAIN

NEW WINDOW ASSEMBLY

NEW DOOR/FRAME ASSEMBLY

1 HR. FIRE-RATED WALL (EXISTING)

2 HR. FIRE-RATED WALL (EXISTING)

LEGEND - RENOVATION

FIRE-RATED WALL (NEW OR EXISTING

1 HOUR UNLESS NOTED OTHERWISE)

TRUE NORTH PLAN

NORTH

TRUE NORTH PLAN

NORTH

TRUE NORTH PLAN

NORTH TRUE NORTH PLAN

1 TELECOM ROOM A540 - ROOM RENOVATION

A540

44 66

20 26 30

15'-8"±

9' -3

X3A

X3A X3A

TELECOM

ROOM

A540

EXIST.

CHIEF OFFICE

B540

EXIST.

CORRIDOR

C*5*1

EXIST.

ADMIN. ASST.

B541

EXIST.

CHIEF MED.

B542

2 TELECOM ROOM A540 - CEILING RENOVATION

SCALE: 1/4" = 1'-0"

OD

TELECOM

ROOM

A540

EXIST.

CHIEF OFFICE

B540

EXIST.

CORRIDOR

C*5*1

EXIST.

ADMIN. ASST.

B541

EXIST.

CHIEF MED.

B542

OD

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANTRevisions: Date:

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

FULLY SPRINKLERED

539-21-701

4-MAY-2022

100% CONSTRUCTION

DOCUMENTS

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST., CINCINNATI, OH

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

ETS

T

TA

GE

S

R I

E T E X

FO

T

CE

TI

H

AS

DER CRA

F. BIAN

C

OJ

O

SE

P

H

7 6 22 1

5/4/22

AS-405-C.1.5

ENLARGED FLOOR PLAN -

FIFTH FLOOR - RENOVATION

IAR

IAR, JFB

1. REFERENCE GENERAL NOTES ON SHEET GI-004.

2. UNLESS NOTED OTHERWISE, ALL EXISTING WALLS

ARE 5/8" GYPSUM BOARD/3 5/8"METAL STUD FRAMED

TO UNDERSIDE OF PRIMARY BUILDING FRAMING

STRUCTURE (1 HR. FIRE RATED - CONSTRUCTION

SIMILAR TO U.l. DESIGN NO. U465). CONTRACTOR TO

VERIFY.

3. UNLESS NOTED OTHERWISE, ALL EXISTING DOOR

ASSEMBLIES ARE SOLID CORE WOOD DOORS/HOLLOW

METAL FRAME TYPICAL (3'-0" X 7'-0").

4. UNLESS NOTED OTHERWISE ALL EXISTING LAY-IN

CEILING ASSEMBLIES ARE 2' X 2' STANDARD GRID WITH

FISSURED TILES AT 8'-0" A.F.F. TYPICAL.

5. UNLESS NOTED OTHERWISE, ALL EXISTING STEEL

COLUMN FUR-OUTS ARE GYPSUM BOARD/METAL STUD

FRAMED TYPICAL.

6. PARTIAL OR ENTIRE RECONSTRUCTION OF SOME

EXISTING CEILING ASSEMBLIES THOUGH OUT THE

ENTIRE BUILDING(S), ESPECIALLY IN CORRIDORS,

WILL BE NECESSARY. REFERENCE ALL DISCIPLINE

DEMOLITION DRAWINGS. RECONSTRUCTION IS TO

INCLUDE MISCELLANEOUS PATCHING /REPAIR TO

MATCH EXISTING OR BETTER CONDITIONS.

7. EXISTING FIRE-RATED WALL IDENTIFICATION

INDICATED ONLY FOR IMMEDIATE AFFECTED ROOM

WALLS. CONTRACTOR SHALL VERIFY FULL EXTENT OF

EXISTING FIRE-RATED WALLS AT ADJACENT AREAS.

8. ALL NEW WALLS SHALL BE PARTITION TYPE '1' UNLESS

OTHERWISE NOTED.

9. UNLESS NOTED OTHERWISE AT ALL ROOMS WHERE

EXISTING LAY-IN CEILING IS REMOVED AND IS TO

BECOME A "NO CEILING" ROOM, THE EXISTING

GYPSUM BOARD ABOVE PREVIOUSLY REMOVED

CEILING IS TO BE FULLY TAPED, FLOATED, TEXTURED

AND PAINTED TO MATCH EXISTING WALLS.

GENERAL NOTES - RENOVATION

1. EXISTING DOOR/FRAME ASSEMBLY TO REMAIN.

2. PROVIDE CARD READER.

3. PROVIDE ROOM SIGNAGE.

4. PROVIDE NEW FLOORING AND BASE AS SCHEDULED.

5. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE IN THIS ROOM THAT MAY REQUIRE MINOR

DEMOLITION, PATCHING AND REPAIR OF EXISTING

FLOOR SUBSTRATE, WALL OR MISCELLANEOUS

ASSEMBLIES.

6. PROVIDE 8'x4'x3/4" 'AC' FACED FIRE-RATED PLYWOOD

VERTICALLY ON ALL WALLS AS INDICATED. PAINT WITH 2

COATS MIN. FIRE-RATED PAINT. COORDINATE EXACT

LOCATION A.F.F. WITH TECHNOLOGY AND ELECTRICAL

DRAWINGS AND EXISTING CONDITIONS.

7. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE OF EXISTING AND NEW COMPONENTS AT

CEILING LEVEL.

8. EXISTING FLOOR AND BASE TO REMAIN. REPAIR AS

NECESSARY TO MATCH EXISTING CONDITIONS OR

BETTER.

9. EXISTING VCT FLOORING AND RUBBER BASE TO REMAIN.

10. LIMITED RENOVATION TO EXISTING CEILING ASSEMBLY

PER MEP AND TECHNOLOGY DRAWINGS WORK SCOPE.

11. RELOCATED EXISTING MARKER BOARD.

12. RELOCATED EXISTING MILLWORK.

13. CEILING FUR-DOWN ABOVE.

14. NEW GYPSUM BOARD/METAL STUD FRAMED FUR-DOWN

TO MATCH EXISTING HEIGHT. NO JOINTS

UNLESS NOTED OTHERWISE.

15. RELOCATED EXISTING LIGHT FIXTURE.

16. RELOCATED EXISTING TV MONITOR.

17. EXISTING ALUMINUM FLOOR AND WALL (EACH SIDE)

EXPANSION JOINT COVERS TO REMAIN.

18. EXISTING GYPSUM BOARD/METAL STUD FRAMED

FUR-DOWN TO REMAIN.

19. RELOCATED EXISTING FIRE EXTINGUISHER.

20. EXISTING EXTERIOR WINDOW TO REMAIN.

21. REINSTALL EXISTING SALVAGED WOOD BASE AND CHAIR

RAIL. PROVIDE BALANCE OF MATERIAL AS NEEDED TO

COMPLETE JOB. PAINT ALL BASE AND CHAIR RAIL IN

ENTIRE ROOM.

22. EXISTING PLASTER ON CMU TO UNDERSIDE OF EXISTING

STRUCTURE (4" OR 8" CMU PER WALL THICKNESS

DEPICTED GRAPHICALLY). FIRE-RATED WALL.

CONTRACTOR VERIFY.

23. EXISTING ROOM SIGNAGE.

24. EXISTING CARD READER.

25. REFERENCE DOOR SCHEDULE.

26. PAINT INTERIOR SIDE OF EXISTING WINDOW GLAZING

ONLY "FLAT BLACK".

27. REINSTALLED EXISTING ROOM SIGNAGE.

28. REINSTALLED EXISTING CARD READER.

29. PLASTER ASSEMBLY INFILL AT EXISTING WALL AS

DETAILED AT EXISTING WINDOW OPENING.

30. ENSURE EXISTING WALL VENT IS SECURELY CLOSED

SHUT PRIOR TO COVER-UP.

31. PROVIDE WALL PROTECTION TO MATCH EXISTING.

32. PROVIDE NEW CEILING AS SCHEDULED.

33. PROVIDE GYPSUM BOARD/STEEL STUD FRAMED

FUR-DOWN AS DETAILED.

34. PROVIDE 2' X 2' RAISED FLOOR SYSTEM AT 10" ABOVE

THE 4TH FLOOR LEVEL.

35. ELECTRICAL CONDUITS AND MECHANICAL PIPING PER

MEP DRAWINGS.

36. PROVIDE 5/8" GYPSUM BOARD WHERE EXISTING TILE

WAINSCOT AND SUBSTRATE WAS REMOVED. TEXTURE

AND FINISH TO MATCH EXISTING ADJACENT WALLS (4'-0"±

HIGH, LOCATE AS INDICATED BY HEAVY LINE).

37. TEXTURE AND FINISH EXISTING GYPSUM BOARD

SUBSTRATE TO MATCH EXISTING ADJACENT WALLS.

38. GYPSUM BOARD ASSEMBLY INFILL AS DETAILED AT

EXISTING WINDOW OPENING.

39. PROVIDE INFILL PER KEYED NOTE 29 AT VOID LEFT BY

HEATER REMOVED.

40. PROVIDE 1" THICK MINIMUM CONCRETE INFILL FLUSH

WITH EXISTING CONCRETE TOPPING WHERE PORTIONS

OF EXISTING CMU WALLS ARE REMOVED.

41. PROVIDE PAINTED WOOD CHAIR RAIL TO MATCH

EXISTING.

42. REINSTALLED EXISTING SHELF.

43. PROVIDE GYPSUM BOARD/METAL STUD FRAMED CHASE

FROM FLOORS ABOVE . MINIMIZE SIZE AND REFERENCE

MEP DRAWINGS FOR COMPONENTS TO BE IN CHASE.

44. RAMP AND RAILS BY RAISED FLOOR SYSTEM

MANUFACTURER.

45. ROOM PERIMETER WALLS TO BE FULLY SEALED TOP

AND BOTTOM ON BOTH SIDES OF WALL. EXTERIOR WALL

SEAL INTERIOR SIDE ONLY.

KEYED NOTES - RENOVATION

46. TEMPORARY ALUMINUM RAMP BY CONTRACTOR TO BE

RETURNED TO OWNER AT END OF JOB.

47. MODULAR BRICK INFILL ON EXTERIOR TO MATCH

EXISTING. TOOTH-IN AND MATCH MORTAR.

KEYED NOTES - RENOVATION (CONT.)

EXISTING WALL TO REMAIN

NEW WALL CONSTRUCTION

EXISTING DOOR/FRAME ASSEMBLY

TO REMAIN

EXISTING WINDOW ASSEMBLY

TO REMAIN

NEW WINDOW ASSEMBLY

NEW DOOR/FRAME ASSEMBLY

1 HR. FIRE-RATED WALL (EXISTING)

2 HR. FIRE-RATED WALL (EXISTING)

LEGEND - RENOVATION

FIRE-RATED WALL (NEW OR EXISTING

1 HOUR UNLESS NOTED OTHERWISE)

TRUE NORTH PLAN

NORTH

TRUE NORTH PLAN

'-2

/4

TELECOM

ROOM

A643

EXIST.

MEDICAL RESIDENT

A642

EXIST.

STAIR 1

S*6*1

EXIST.

CORRIDOR

C*6*1

15'-5 7/8"±

A643

1 TELECOM ROOM A643 - ROOM RENOVATION

SCALE: 1/4" = 1'-0"

X3B

X3C

X3B

EXIST.

MEDICAL RESIDENT

A642

EXIST.

STAIR 1

S*6*1

EXIST.

CORRIDOR

C*6*1

TELECOM

ROOM

A643

2 TELECOM ROOM A643 - CEILING RENOVATION

SCALE: 1/4" = 1'-0"

OD

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANTRevisions: Date:

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

FULLY SPRINKLERED

539-21-701

4-MAY-2022

100% CONSTRUCTION

DOCUMENTS

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST., CINCINNATI, OH

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

ETS

T

TA

GE

S

R I

E T E X

FO

T

CE

TI

H

AS

DER CRA

F. BIAN

C

OJO

S

EP

H

7 6 22 1

5/4/22

AS-406-C.1.6

ENLARGED FLOOR PLANS -

6TH FLOOR RENOVATION

IAR

C1

1. REFERENCE GENERAL NOTES ON SHEET GI-004.

2. UNLESS NOTED OTHERWISE, ALL EXISTING WALLS

ARE 5/8" GYPSUM BOARD/3 5/8"METAL STUD FRAMED

TO UNDERSIDE OF PRIMARY BUILDING FRAMING

STRUCTURE (1 HR. FIRE RATED - CONSTRUCTION

SIMILAR TO U.l. DESIGN NO. U465). CONTRACTOR TO

VERIFY.

3. UNLESS NOTED OTHERWISE, ALL EXISTING DOOR

ASSEMBLIES ARE SOLID CORE WOOD DOORS/HOLLOW

METAL FRAME TYPICAL (3'-0" X 7'-0").

4. UNLESS NOTED OTHERWISE ALL EXISTING LAY-IN

CEILING ASSEMBLIES ARE 2' X 2' STANDARD GRID WITH

FISSURED TILES AT 8'-0" A.F.F. TYPICAL.

5. UNLESS NOTED OTHERWISE, ALL EXISTING STEEL

COLUMN FUR-OUTS ARE GYPSUM BOARD/METAL STUD

FRAMED TYPICAL.

6. PARTIAL OR ENTIRE RECONSTRUCTION OF SOME

EXISTING CEILING ASSEMBLIES THOUGH OUT THE

ENTIRE BUILDING(S), ESPECIALLY IN CORRIDORS,

WILL BE NECESSARY. REFERENCE ALL DISCIPLINE

DEMOLITION DRAWINGS. RECONSTRUCTION IS TO

INCLUDE MISCELLANEOUS PATCHING /REPAIR TO

MATCH EXISTING OR BETTER CONDITIONS.

7. EXISTING FIRE-RATED WALL IDENTIFICATION

INDICATED ONLY FOR IMMEDIATE AFFECTED ROOM

WALLS. CONTRACTOR SHALL VERIFY FULL EXTENT OF

EXISTING FIRE-RATED WALLS AT ADJACENT AREAS.

8. ALL NEW WALLS SHALL BE PARTITION TYPE '1' UNLESS

OTHERWISE NOTED.

9. UNLESS NOTED OTHERWISE AT ALL ROOMS WHERE

EXISTING LAY-IN CEILING IS REMOVED AND IS TO

BECOME A "NO CEILING" ROOM, THE EXISTING

GYPSUM BOARD ABOVE PREVIOUSLY REMOVED

CEILING IS TO BE FULLY TAPED, FLOATED, TEXTURED

AND PAINTED TO MATCH EXISTING WALLS.

GENERAL NOTES - RENOVATION

1. EXISTING DOOR/FRAME ASSEMBLY TO REMAIN.

2. PROVIDE CARD READER.

3. PROVIDE ROOM SIGNAGE.

4. PROVIDE NEW FLOORING AND BASE AS SCHEDULED.

5. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE IN THIS ROOM THAT MAY REQUIRE MINOR

DEMOLITION, PATCHING AND REPAIR OF EXISTING

FLOOR SUBSTRATE, WALL OR MISCELLANEOUS

ASSEMBLIES.

6. PROVIDE 8'x4'x3/4" 'AC' FACED FIRE-RATED PLYWOOD

VERTICALLY ON ALL WALLS AS INDICATED. PAINT WITH 2

COATS MIN. FIRE-RATED PAINT. COORDINATE EXACT

LOCATION A.F.F. WITH TECHNOLOGY AND ELECTRICAL

DRAWINGS AND EXISTING CONDITIONS.

7. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE OF EXISTING AND NEW COMPONENTS AT

CEILING LEVEL.

8. EXISTING FLOOR AND BASE TO REMAIN. REPAIR AS

NECESSARY TO MATCH EXISTING CONDITIONS OR

BETTER.

9. EXISTING VCT FLOORING AND RUBBER BASE TO REMAIN.

10. LIMITED RENOVATION TO EXISTING CEILING ASSEMBLY

PER MEP AND TECHNOLOGY DRAWINGS WORK SCOPE.

11. RELOCATED EXISTING MARKER BOARD.

12. RELOCATED EXISTING MILLWORK.

13. CEILING FUR-DOWN ABOVE.

14. NEW GYPSUM BOARD/METAL STUD FRAMED FUR-DOWN

TO MATCH EXISTING HEIGHT. NO JOINTS

UNLESS NOTED OTHERWISE.

15. RELOCATED EXISTING LIGHT FIXTURE.

16. RELOCATED EXISTING TV MONITOR.

17. EXISTING ALUMINUM FLOOR AND WALL (EACH SIDE)

EXPANSION JOINT COVERS TO REMAIN.

18. EXISTING GYPSUM BOARD/METAL STUD FRAMED

FUR-DOWN TO REMAIN.

19. RELOCATED EXISTING FIRE EXTINGUISHER.

20. EXISTING EXTERIOR WINDOW TO REMAIN.

21. REINSTALL EXISTING SALVAGED WOOD BASE AND CHAIR

RAIL. PROVIDE BALANCE OF MATERIAL AS NEEDED TO

COMPLETE JOB. PAINT ALL BASE AND CHAIR RAIL IN

ENTIRE ROOM.

22. EXISTING PLASTER ON CMU TO UNDERSIDE OF EXISTING

STRUCTURE (4" OR 8" CMU PER WALL THICKNESS

DEPICTED GRAPHICALLY). FIRE-RATED WALL.

CONTRACTOR VERIFY.

23. EXISTING ROOM SIGNAGE.

24. EXISTING CARD READER.

25. REFERENCE DOOR SCHEDULE.

26. PAINT INTERIOR SIDE OF EXISTING WINDOW GLAZING

ONLY "FLAT BLACK".

27. REINSTALLED EXISTING ROOM SIGNAGE.

28. REINSTALLED EXISTING CARD READER.

29. PLASTER ASSEMBLY INFILL AT EXISTING WALL AS

DETAILED AT EXISTING WINDOW OPENING.

30. ENSURE EXISTING WALL VENT IS SECURELY CLOSED

SHUT PRIOR TO COVER-UP.

31. PROVIDE WALL PROTECTION TO MATCH EXISTING.

32. PROVIDE NEW CEILING AS SCHEDULED.

33. PROVIDE GYPSUM BOARD/STEEL STUD FRAMED

FUR-DOWN AS DETAILED.

34. PROVIDE 2' X 2' RAISED FLOOR SYSTEM AT 10" ABOVE

THE 4TH FLOOR LEVEL.

35. ELECTRICAL CONDUITS AND MECHANICAL PIPING PER

MEP DRAWINGS.

36. PROVIDE 5/8" GYPSUM BOARD WHERE EXISTING TILE

WAINSCOT AND SUBSTRATE WAS REMOVED. TEXTURE

AND FINISH TO MATCH EXISTING ADJACENT WALLS (4'-0"±

HIGH, LOCATE AS INDICATED BY HEAVY LINE).

37. TEXTURE AND FINISH EXISTING GYPSUM BOARD

SUBSTRATE TO MATCH EXISTING ADJACENT WALLS.

38. GYPSUM BOARD ASSEMBLY INFILL AS DETAILED AT

EXISTING WINDOW OPENING.

39. PROVIDE INFILL PER KEYED NOTE 29 AT VOID LEFT BY

HEATER REMOVED.

40. PROVIDE 1" THICK MINIMUM CONCRETE INFILL FLUSH

WITH EXISTING CONCRETE TOPPING WHERE PORTIONS

OF EXISTING CMU WALLS ARE REMOVED.

41. PROVIDE PAINTED WOOD CHAIR RAIL TO MATCH

EXISTING.

42. REINSTALLED EXISTING SHELF.

43. PROVIDE GYPSUM BOARD/METAL STUD FRAMED CHASE

FROM FLOORS ABOVE . MINIMIZE SIZE AND REFERENCE

MEP DRAWINGS FOR COMPONENTS TO BE IN CHASE.

44. RAMP AND RAILS BY RAISED FLOOR SYSTEM

MANUFACTURER.

45. ROOM PERIMETER WALLS TO BE FULLY SEALED TOP

AND BOTTOM ON BOTH SIDES OF WALL. EXTERIOR WALL

SEAL INTERIOR SIDE ONLY.

KEYED NOTES - RENOVATION

46. TEMPORARY ALUMINUM RAMP BY CONTRACTOR TO BE

RETURNED TO OWNER AT END OF JOB.

47. MODULAR BRICK INFILL ON EXTERIOR TO MATCH

EXISTING. TOOTH-IN AND MATCH MORTAR.

KEYED NOTES - RENOVATION (CONT.)

EXISTING WALL TO REMAIN

NEW WALL CONSTRUCTION

EXISTING DOOR/FRAME ASSEMBLY

TO REMAIN

EXISTING WINDOW ASSEMBLY

TO REMAIN

NEW WINDOW ASSEMBLY

NEW DOOR/FRAME ASSEMBLY

1 HR. FIRE-RATED WALL (EXISTING)

2 HR. FIRE-RATED WALL (EXISTING)

LEGEND - RENOVATION

FIRE-RATED WALL (NEW OR EXISTING

1 HOUR UNLESS NOTED OTHERWISE)

TRUE NORTH PLAN

NORTH

7' -2

1 25

8 9 8 98 9

A704A

A702A

8'-3"±

6' -2

20 26

38 30 X2B

X2C

X2B

X2B

X2C

X2B

EXIST.

INTERVIEW

A702

EXIST.

STORAGE

A704B

STORAGE

A702A

EXIST. SENSORY

THERAPY

A704

EXIST.

CORRIDOR

C*7*2

7'-4"±

STORAGE

A704A

1 STORAGE A702A & STORAGE A704A - ROOM RENOVATION

SCALE: 1/4" = 1'-0"

3 TELECOM ROOM A732A - ROOM RENOVATION

SCALE: 1/4" = 1'-0"

EXIST. OCCUPATIONAL

THERAPY

A732

EXIST.

CORRIDOR

C*7*1

15'-6"±

TELECOM

ROOM

A732A

A732A

A732

'-0

44 666

X1A

X1A

20 26 30

2 STORAGE A702A & STORAGE A704A - CEILING RENOVATION

SCALE: 1/4" = 1'-0"

EXIST.

INTERVIEW

A702

STORAGE

A702A

EXIST. SENSORY

THERAPY

A704

EXIST.

CORRIDOR

C*7*2

STORAGE

A704A

EXIST.

STORAGE

A704B

4 TELECOM ROOM A732A - CEILING RENOVATION

SCALE: 1/4" = 1'-0"

EXIST. OCCUPATIONAL

THERAPY

A732

EXIST.

CORRIDOR

C*7*1

TELECOM

ROOM

A732A

OD

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANTRevisions: Date:

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

FULLY SPRINKLERED

539-21-701

4-MAY-2022

100% CONSTRUCTION

DOCUMENTS

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST., CINCINNATI, OH

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

ETS

T

TA

GE

S

R I

E T E X

FO

T

CE

TI

H

AS

DER CRA

F. BIAN

C

OJ

O

SE

P

H

7 6 22 1

5/4/22

AS-407-C.1.7

ENLARGED FLOOR PLAN -

SEVENTH FLOOR - RENOVATION

IAR

IAR, JFB

1. REFERENCE GENERAL NOTES ON SHEET GI-004.

2. UNLESS NOTED OTHERWISE, ALL EXISTING WALLS

ARE 5/8" GYPSUM BOARD/3 5/8"METAL STUD FRAMED

TO UNDERSIDE OF PRIMARY BUILDING FRAMING

STRUCTURE (1 HR. FIRE RATED - CONSTRUCTION

SIMILAR TO U.l. DESIGN NO. U465). CONTRACTOR TO

VERIFY.

3. UNLESS NOTED OTHERWISE, ALL EXISTING DOOR

ASSEMBLIES ARE SOLID CORE WOOD DOORS/HOLLOW

METAL FRAME TYPICAL (3'-0" X 7'-0").

4. UNLESS NOTED OTHERWISE ALL EXISTING LAY-IN

CEILING ASSEMBLIES ARE 2' X 2' STANDARD GRID WITH

FISSURED TILES AT 8'-0" A.F.F. TYPICAL.

5. UNLESS NOTED OTHERWISE, ALL EXISTING STEEL

COLUMN FUR-OUTS ARE GYPSUM BOARD/METAL STUD

FRAMED TYPICAL.

6. PARTIAL OR ENTIRE RECONSTRUCTION OF SOME

EXISTING CEILING ASSEMBLIES THOUGH OUT THE

ENTIRE BUILDING(S), ESPECIALLY IN CORRIDORS,

WILL BE NECESSARY. REFERENCE ALL DISCIPLINE

DEMOLITION DRAWINGS. RECONSTRUCTION IS TO

INCLUDE MISCELLANEOUS PATCHING /REPAIR TO

MATCH EXISTING OR BETTER CONDITIONS.

7. EXISTING FIRE-RATED WALL IDENTIFICATION

INDICATED ONLY FOR IMMEDIATE AFFECTED ROOM

WALLS. CONTRACTOR SHALL VERIFY FULL EXTENT OF

EXISTING FIRE-RATED WALLS AT ADJACENT AREAS.

8. ALL NEW WALLS SHALL BE PARTITION TYPE '1' UNLESS

OTHERWISE NOTED.

9. UNLESS NOTED OTHERWISE AT ALL ROOMS WHERE

EXISTING LAY-IN CEILING IS REMOVED AND IS TO

BECOME A "NO CEILING" ROOM, THE EXISTING

GYPSUM BOARD ABOVE PREVIOUSLY REMOVED

CEILING IS TO BE FULLY TAPED, FLOATED, TEXTURED

AND PAINTED TO MATCH EXISTING WALLS.

GENERAL NOTES - RENOVATION

1. EXISTING DOOR/FRAME ASSEMBLY TO REMAIN.

2. PROVIDE CARD READER.

3. PROVIDE ROOM SIGNAGE.

4. PROVIDE NEW FLOORING AND BASE AS SCHEDULED.

5. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE IN THIS ROOM THAT MAY REQUIRE MINOR

DEMOLITION, PATCHING AND REPAIR OF EXISTING

FLOOR SUBSTRATE, WALL OR MISCELLANEOUS

ASSEMBLIES.

6. PROVIDE 8'x4'x3/4" 'AC' FACED FIRE-RATED PLYWOOD

VERTICALLY ON ALL WALLS AS INDICATED. PAINT WITH 2

COATS MIN. FIRE-RATED PAINT. COORDINATE EXACT

LOCATION A.F.F. WITH TECHNOLOGY AND ELECTRICAL

DRAWINGS AND EXISTING CONDITIONS.

7. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE OF EXISTING AND NEW COMPONENTS AT

CEILING LEVEL.

8. EXISTING FLOOR AND BASE TO REMAIN. REPAIR AS

NECESSARY TO MATCH EXISTING CONDITIONS OR

BETTER.

9. EXISTING VCT FLOORING AND RUBBER BASE TO REMAIN.

10. LIMITED RENOVATION TO EXISTING CEILING ASSEMBLY

PER MEP AND TECHNOLOGY DRAWINGS WORK SCOPE.

11. RELOCATED EXISTING MARKER BOARD.

12. RELOCATED EXISTING MILLWORK.

13. CEILING FUR-DOWN ABOVE.

14. NEW GYPSUM BOARD/METAL STUD FRAMED FUR-DOWN

TO MATCH EXISTING HEIGHT. NO JOINTS

UNLESS NOTED OTHERWISE.

15. RELOCATED EXISTING LIGHT FIXTURE.

16. RELOCATED EXISTING TV MONITOR.

17. EXISTING ALUMINUM FLOOR AND WALL (EACH SIDE)

EXPANSION JOINT COVERS TO REMAIN.

18. EXISTING GYPSUM BOARD/METAL STUD FRAMED

FUR-DOWN TO REMAIN.

19. RELOCATED EXISTING FIRE EXTINGUISHER.

20. EXISTING EXTERIOR WINDOW TO REMAIN.

21. REINSTALL EXISTING SALVAGED WOOD BASE AND CHAIR

RAIL. PROVIDE BALANCE OF MATERIAL AS NEEDED TO

COMPLETE JOB. PAINT ALL BASE AND CHAIR RAIL IN

ENTIRE ROOM.

22. EXISTING PLASTER ON CMU TO UNDERSIDE OF EXISTING

STRUCTURE (4" OR 8" CMU PER WALL THICKNESS

DEPICTED GRAPHICALLY). FIRE-RATED WALL.

CONTRACTOR VERIFY.

23. EXISTING ROOM SIGNAGE.

24. EXISTING CARD READER.

25. REFERENCE DOOR SCHEDULE.

26. PAINT INTERIOR SIDE OF EXISTING WINDOW GLAZING

ONLY "FLAT BLACK".

27. REINSTALLED EXISTING ROOM SIGNAGE.

28. REINSTALLED EXISTING CARD READER.

29. PLASTER ASSEMBLY INFILL AT EXISTING WALL AS

DETAILED AT EXISTING WINDOW OPENING.

30. ENSURE EXISTING WALL VENT IS SECURELY CLOSED

SHUT PRIOR TO COVER-UP.

31. PROVIDE WALL PROTECTION TO MATCH EXISTING.

32. PROVIDE NEW CEILING AS SCHEDULED.

33. PROVIDE GYPSUM BOARD/STEEL STUD FRAMED

FUR-DOWN AS DETAILED.

34. PROVIDE 2' X 2' RAISED FLOOR SYSTEM AT 10" ABOVE

THE 4TH FLOOR LEVEL.

35. ELECTRICAL CONDUITS AND MECHANICAL PIPING PER

MEP DRAWINGS.

36. PROVIDE 5/8" GYPSUM BOARD WHERE EXISTING TILE

WAINSCOT AND SUBSTRATE WAS REMOVED. TEXTURE

AND FINISH TO MATCH EXISTING ADJACENT WALLS (4'-0"±

HIGH, LOCATE AS INDICATED BY HEAVY LINE).

37. TEXTURE AND FINISH EXISTING GYPSUM BOARD

SUBSTRATE TO MATCH EXISTING ADJACENT WALLS.

38. GYPSUM BOARD ASSEMBLY INFILL AS DETAILED AT

EXISTING WINDOW OPENING.

39. PROVIDE INFILL PER KEYED NOTE 29 AT VOID LEFT BY

HEATER REMOVED.

40. PROVIDE 1" THICK MINIMUM CONCRETE INFILL FLUSH

WITH EXISTING CONCRETE TOPPING WHERE PORTIONS

OF EXISTING CMU WALLS ARE REMOVED.

41. PROVIDE PAINTED WOOD CHAIR RAIL TO MATCH

EXISTING.

42. REINSTALLED EXISTING SHELF.

43. PROVIDE GYPSUM BOARD/METAL STUD FRAMED CHASE

FROM FLOORS ABOVE . MINIMIZE SIZE AND REFERENCE

MEP DRAWINGS FOR COMPONENTS TO BE IN CHASE.

44. RAMP AND RAILS BY RAISED FLOOR SYSTEM

MANUFACTURER.

45. ROOM PERIMETER WALLS TO BE FULLY SEALED TOP

AND BOTTOM ON BOTH SIDES OF WALL. EXTERIOR WALL

SEAL INTERIOR SIDE ONLY.

KEYED NOTES - RENOVATION

46. TEMPORARY ALUMINUM RAMP BY CONTRACTOR TO BE

RETURNED TO OWNER AT END OF JOB.

47. MODULAR BRICK INFILL ON EXTERIOR TO MATCH

EXISTING. TOOTH-IN AND MATCH MORTAR.

KEYED NOTES - RENOVATION (CONT.)

EXISTING WALL TO REMAIN

NEW WALL CONSTRUCTION

EXISTING DOOR/FRAME ASSEMBLY

TO REMAIN

EXISTING WINDOW ASSEMBLY

TO REMAIN

NEW WINDOW ASSEMBLY

NEW DOOR/FRAME ASSEMBLY

1 HR. FIRE-RATED WALL (EXISTING)

2 HR. FIRE-RATED WALL (EXISTING)

LEGEND - RENOVATION

FIRE-RATED WALL (NEW OR EXISTING

1 HOUR UNLESS NOTED OTHERWISE)

TRUE NORTH PLAN

NORTH

TRUE NORTH PLAN

NORTH

TRUE NORTH PLAN

NORTH

1 TELECOM ROOM A838 - ROOM RENOVATION

A838

15'-11"±

9' -7

8 9

20 26 30

X3B

X3B

TELECOM

ROOM

A838

EXIST.

WAITING

B801

EXIST.

CONFERENCE

A839EXIST.

CORRIDOR

C*8*1

2 TELECOM ROOM A838 - CEILING RENOVATION

SCALE: 1/4" = 1'-0"

TELECOM

ROOM

A838

EXIST.

WAITING

B801

EXIST.

CONFERENCE

A839EXIST.

CORRIDOR

C*8*1

OD OD

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANTRevisions: Date:

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

FULLY SPRINKLERED

539-21-701

4-MAY-2022

100% CONSTRUCTION

DOCUMENTS

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST., CINCINNATI, OH

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

ETS

T

TA

GE

S

R I

E T E X

FO

T

CE

TI

H

AS

DER CRA

F. BIAN

C

OJ

O

SE

P

H

7 6 22 1

5/4/22

AS-408-C.1.8

ENLARGED FLOOR PLAN -

EIGHTH FLOOR - RENOVATION

IAR

IAR, JFB

1. REFERENCE GENERAL NOTES ON SHEET GI-004.

2. UNLESS NOTED OTHERWISE, ALL EXISTING WALLS

ARE 5/8" GYPSUM BOARD/3 5/8"METAL STUD FRAMED

TO UNDERSIDE OF PRIMARY BUILDING FRAMING

STRUCTURE (1 HR. FIRE RATED - CONSTRUCTION

SIMILAR TO U.l. DESIGN NO. U465). CONTRACTOR TO

VERIFY.

3. UNLESS NOTED OTHERWISE, ALL EXISTING DOOR

ASSEMBLIES ARE SOLID CORE WOOD DOORS/HOLLOW

METAL FRAME TYPICAL (3'-0" X 7'-0").

4. UNLESS NOTED OTHERWISE ALL EXISTING LAY-IN

CEILING ASSEMBLIES ARE 2' X 2' STANDARD GRID WITH

FISSURED TILES AT 8'-0" A.F.F. TYPICAL.

5. UNLESS NOTED OTHERWISE, ALL EXISTING STEEL

COLUMN FUR-OUTS ARE GYPSUM BOARD/METAL STUD

FRAMED TYPICAL.

6. PARTIAL OR ENTIRE RECONSTRUCTION OF SOME

EXISTING CEILING ASSEMBLIES THOUGH OUT THE

ENTIRE BUILDING(S), ESPECIALLY IN CORRIDORS,

WILL BE NECESSARY. REFERENCE ALL DISCIPLINE

DEMOLITION DRAWINGS. RECONSTRUCTION IS TO

INCLUDE MISCELLANEOUS PATCHING /REPAIR TO

MATCH EXISTING OR BETTER CONDITIONS.

7. EXISTING FIRE-RATED WALL IDENTIFICATION

INDICATED ONLY FOR IMMEDIATE AFFECTED ROOM

WALLS. CONTRACTOR SHALL VERIFY FULL EXTENT OF

EXISTING FIRE-RATED WALLS AT ADJACENT AREAS.

8. ALL NEW WALLS SHALL BE PARTITION TYPE '1' UNLESS

OTHERWISE NOTED.

9. UNLESS NOTED OTHERWISE AT ALL ROOMS WHERE

EXISTING LAY-IN CEILING IS REMOVED AND IS TO

BECOME A "NO CEILING" ROOM, THE EXISTING

GYPSUM BOARD ABOVE PREVIOUSLY REMOVED

CEILING IS TO BE FULLY TAPED, FLOATED, TEXTURED

AND PAINTED TO MATCH EXISTING WALLS.

GENERAL NOTES - RENOVATION

1. EXISTING DOOR/FRAME ASSEMBLY TO REMAIN.

2. PROVIDE CARD READER.

3. PROVIDE ROOM SIGNAGE.

4. PROVIDE NEW FLOORING AND BASE AS SCHEDULED.

5. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE IN THIS ROOM THAT MAY REQUIRE MINOR

DEMOLITION, PATCHING AND REPAIR OF EXISTING

FLOOR SUBSTRATE, WALL OR MISCELLANEOUS

ASSEMBLIES.

6. PROVIDE 8'x4'x3/4" 'AC' FACED FIRE-RATED PLYWOOD

VERTICALLY ON ALL WALLS AS INDICATED. PAINT WITH 2

COATS MIN. FIRE-RATED PAINT. COORDINATE EXACT

LOCATION A.F.F. WITH TECHNOLOGY AND ELECTRICAL

DRAWINGS AND EXISTING CONDITIONS.

7. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE OF EXISTING AND NEW COMPONENTS AT

CEILING LEVEL.

8. EXISTING FLOOR AND BASE TO REMAIN. REPAIR AS

NECESSARY TO MATCH EXISTING CONDITIONS OR

BETTER.

9. EXISTING VCT FLOORING AND RUBBER BASE TO REMAIN.

10. LIMITED RENOVATION TO EXISTING CEILING ASSEMBLY

PER MEP AND TECHNOLOGY DRAWINGS WORK SCOPE.

11. RELOCATED EXISTING MARKER BOARD.

12. RELOCATED EXISTING MILLWORK.

13. CEILING FUR-DOWN ABOVE.

14. NEW GYPSUM BOARD/METAL STUD FRAMED FUR-DOWN

TO MATCH EXISTING HEIGHT. NO JOINTS

UNLESS NOTED OTHERWISE.

15. RELOCATED EXISTING LIGHT FIXTURE.

16. RELOCATED EXISTING TV MONITOR.

17. EXISTING ALUMINUM FLOOR AND WALL (EACH SIDE)

EXPANSION JOINT COVERS TO REMAIN.

18. EXISTING GYPSUM BOARD/METAL STUD FRAMED

FUR-DOWN TO REMAIN.

19. RELOCATED EXISTING FIRE EXTINGUISHER.

20. EXISTING EXTERIOR WINDOW TO REMAIN.

21. REINSTALL EXISTING SALVAGED WOOD BASE AND CHAIR

RAIL. PROVIDE BALANCE OF MATERIAL AS NEEDED TO

COMPLETE JOB. PAINT ALL BASE AND CHAIR RAIL IN

ENTIRE ROOM.

22. EXISTING PLASTER ON CMU TO UNDERSIDE OF EXISTING

STRUCTURE (4" OR 8" CMU PER WALL THICKNESS

DEPICTED GRAPHICALLY). FIRE-RATED WALL.

CONTRACTOR VERIFY.

23. EXISTING ROOM SIGNAGE.

24. EXISTING CARD READER.

25. REFERENCE DOOR SCHEDULE.

26. PAINT INTERIOR SIDE OF EXISTING WINDOW GLAZING

ONLY "FLAT BLACK".

27. REINSTALLED EXISTING ROOM SIGNAGE.

28. REINSTALLED EXISTING CARD READER.

29. PLASTER ASSEMBLY INFILL AT EXISTING WALL AS

DETAILED AT EXISTING WINDOW OPENING.

30. ENSURE EXISTING WALL VENT IS SECURELY CLOSED

SHUT PRIOR TO COVER-UP.

31. PROVIDE WALL PROTECTION TO MATCH EXISTING.

32. PROVIDE NEW CEILING AS SCHEDULED.

33. PROVIDE GYPSUM BOARD/STEEL STUD FRAMED

FUR-DOWN AS DETAILED.

34. PROVIDE 2' X 2' RAISED FLOOR SYSTEM AT 10" ABOVE

THE 4TH FLOOR LEVEL.

35. ELECTRICAL CONDUITS AND MECHANICAL PIPING PER

MEP DRAWINGS.

36. PROVIDE 5/8" GYPSUM BOARD WHERE EXISTING TILE

WAINSCOT AND SUBSTRATE WAS REMOVED. TEXTURE

AND FINISH TO MATCH EXISTING ADJACENT WALLS (4'-0"±

HIGH, LOCATE AS INDICATED BY HEAVY LINE).

37. TEXTURE AND FINISH EXISTING GYPSUM BOARD

SUBSTRATE TO MATCH EXISTING ADJACENT WALLS.

38. GYPSUM BOARD ASSEMBLY INFILL AS DETAILED AT

EXISTING WINDOW OPENING.

39. PROVIDE INFILL PER KEYED NOTE 29 AT VOID LEFT BY

HEATER REMOVED.

40. PROVIDE 1" THICK MINIMUM CONCRETE INFILL FLUSH

WITH EXISTING CONCRETE TOPPING WHERE PORTIONS

OF EXISTING CMU WALLS ARE REMOVED.

41. PROVIDE PAINTED WOOD CHAIR RAIL TO MATCH

EXISTING.

42. REINSTALLED EXISTING SHELF.

43. PROVIDE GYPSUM BOARD/METAL STUD FRAMED CHASE

FROM FLOORS ABOVE . MINIMIZE SIZE AND REFERENCE

MEP DRAWINGS FOR COMPONENTS TO BE IN CHASE.

44. RAMP AND RAILS BY RAISED FLOOR SYSTEM

MANUFACTURER.

45. ROOM PERIMETER WALLS TO BE FULLY SEALED TOP

AND BOTTOM ON BOTH SIDES OF WALL. EXTERIOR WALL

SEAL INTERIOR SIDE ONLY.

KEYED NOTES - RENOVATION

46. TEMPORARY ALUMINUM RAMP BY CONTRACTOR TO BE

RETURNED TO OWNER AT END OF JOB.

47. MODULAR BRICK INFILL ON EXTERIOR TO MATCH

EXISTING. TOOTH-IN AND MATCH MORTAR.

KEYED NOTES - RENOVATION (CONT.)

EXISTING WALL TO REMAIN

NEW WALL CONSTRUCTION

EXISTING DOOR/FRAME ASSEMBLY

TO REMAIN

EXISTING WINDOW ASSEMBLY

TO REMAIN

NEW WINDOW ASSEMBLY

NEW DOOR/FRAME ASSEMBLY

1 HR. FIRE-RATED WALL (EXISTING)

2 HR. FIRE-RATED WALL (EXISTING)

LEGEND - RENOVATION

FIRE-RATED WALL (NEW OR EXISTING

1 HOUR UNLESS NOTED OTHERWISE)

TRUE NORTH PLAN

NORTH

TELECOM

ROOM

A916A

EXIST.

PSYCH. OFFICE

A919B

EXIST.

ELECTRIC

A916D

EXIST.

HAC

A915B

EXIST.

SERVICE LOBBY

A916

14'-8 1/4"±

8' -7

5'

-1 1"

8'-3 3/4"±

A916A

66 3

A916D

1 TELECOM ROOM A916A - ROOM RENOVATION

SCALE: 1/4" = 1'-0"

X1A X1

X1A

X1B X1B

EXIST.

PSYCH. OFFICE

A919B

EXIST.

ELECTRIC

A916D

EXIST.

HAC

A915B

EXIST.

SERVICE LOBBY

A916

TELECOM

ROOM

A916A

2 TELECOM ROOM A916A - CEILING RENOVATION

SCALE: 1/4" = 1'-0"

7 3332

OD

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANTRevisions: Date:

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

FULLY SPRINKLERED

539-21-701

4-MAY-2022

100% CONSTRUCTION

DOCUMENTS

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST., CINCINNATI, OH

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

ETS

T

TA

GE

S

R I

E T E X

FO

T

CE

TI

H

AS

DER CRA

F. BIAN

C

OJO

S

EP

H

7 6 22 1

5/4/22

AS-409-C.1.9

ENLARGED FLOOR PLANS -

9TH FLOOR RENOVATION

IAR

C1

1. REFERENCE GENERAL NOTES ON SHEET GI-004.

2. UNLESS NOTED OTHERWISE, ALL EXISTING WALLS

ARE 5/8" GYPSUM BOARD/3 5/8"METAL STUD FRAMED

TO UNDERSIDE OF PRIMARY BUILDING FRAMING

STRUCTURE (1 HR. FIRE RATED - CONSTRUCTION

SIMILAR TO U.l. DESIGN NO. U465). CONTRACTOR TO

VERIFY.

3. UNLESS NOTED OTHERWISE, ALL EXISTING DOOR

ASSEMBLIES ARE SOLID CORE WOOD DOORS/HOLLOW

METAL FRAME TYPICAL (3'-0" X 7'-0").

4. UNLESS NOTED OTHERWISE ALL EXISTING LAY-IN

CEILING ASSEMBLIES ARE 2' X 2' STANDARD GRID WITH

FISSURED TILES AT 8'-0" A.F.F. TYPICAL.

5. UNLESS NOTED OTHERWISE, ALL EXISTING STEEL

COLUMN FUR-OUTS ARE GYPSUM BOARD/METAL STUD

FRAMED TYPICAL.

6. PARTIAL OR ENTIRE RECONSTRUCTION OF SOME

EXISTING CEILING ASSEMBLIES THOUGH OUT THE

ENTIRE BUILDING(S), ESPECIALLY IN CORRIDORS,

WILL BE NECESSARY. REFERENCE ALL DISCIPLINE

DEMOLITION DRAWINGS. RECONSTRUCTION IS TO

INCLUDE MISCELLANEOUS PATCHING /REPAIR TO

MATCH EXISTING OR BETTER CONDITIONS.

7. EXISTING FIRE-RATED WALL IDENTIFICATION

INDICATED ONLY FOR IMMEDIATE AFFECTED ROOM

WALLS. CONTRACTOR SHALL VERIFY FULL EXTENT OF

EXISTING FIRE-RATED WALLS AT ADJACENT AREAS.

8. ALL NEW WALLS SHALL BE PARTITION TYPE '1' UNLESS

OTHERWISE NOTED.

9. UNLESS NOTED OTHERWISE AT ALL ROOMS WHERE

EXISTING LAY-IN CEILING IS REMOVED AND IS TO

BECOME A "NO CEILING" ROOM, THE EXISTING

GYPSUM BOARD ABOVE PREVIOUSLY REMOVED

CEILING IS TO BE FULLY TAPED, FLOATED, TEXTURED

AND PAINTED TO MATCH EXISTING WALLS.

GENERAL NOTES - RENOVATION

1. EXISTING DOOR/FRAME ASSEMBLY TO REMAIN.

2. PROVIDE CARD READER.

3. PROVIDE ROOM SIGNAGE.

4. PROVIDE NEW FLOORING AND BASE AS SCHEDULED.

5. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE IN THIS ROOM THAT MAY REQUIRE MINOR

DEMOLITION, PATCHING AND REPAIR OF EXISTING

FLOOR SUBSTRATE, WALL OR MISCELLANEOUS

ASSEMBLIES.

6. PROVIDE 8'x4'x3/4" 'AC' FACED FIRE-RATED PLYWOOD

VERTICALLY ON ALL WALLS AS INDICATED. PAINT WITH 2

COATS MIN. FIRE-RATED PAINT. COORDINATE EXACT

LOCATION A.F.F. WITH TECHNOLOGY AND ELECTRICAL

DRAWINGS AND EXISTING CONDITIONS.

7. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE OF EXISTING AND NEW COMPONENTS AT

CEILING LEVEL.

8. EXISTING FLOOR AND BASE TO REMAIN. REPAIR AS

NECESSARY TO MATCH EXISTING CONDITIONS OR

BETTER.

9. EXISTING VCT FLOORING AND RUBBER BASE TO REMAIN.

10. LIMITED RENOVATION TO EXISTING CEILING ASSEMBLY

PER MEP AND TECHNOLOGY DRAWINGS WORK SCOPE.

11. RELOCATED EXISTING MARKER BOARD.

12. RELOCATED EXISTING MILLWORK.

13. CEILING FUR-DOWN ABOVE.

14. NEW GYPSUM BOARD/METAL STUD FRAMED FUR-DOWN

TO MATCH EXISTING HEIGHT. NO JOINTS

UNLESS NOTED OTHERWISE.

15. RELOCATED EXISTING LIGHT FIXTURE.

16. RELOCATED EXISTING TV MONITOR.

17. EXISTING ALUMINUM FLOOR AND WALL (EACH SIDE)

EXPANSION JOINT COVERS TO REMAIN.

18. EXISTING GYPSUM BOARD/METAL STUD FRAMED

FUR-DOWN TO REMAIN.

19. RELOCATED EXISTING FIRE EXTINGUISHER.

20. EXISTING EXTERIOR WINDOW TO REMAIN.

21. REINSTALL EXISTING SALVAGED WOOD BASE AND CHAIR

RAIL. PROVIDE BALANCE OF MATERIAL AS NEEDED TO

COMPLETE JOB. PAINT ALL BASE AND CHAIR RAIL IN

ENTIRE ROOM.

22. EXISTING PLASTER ON CMU TO UNDERSIDE OF EXISTING

STRUCTURE (4" OR 8" CMU PER WALL THICKNESS

DEPICTED GRAPHICALLY). FIRE-RATED WALL.

CONTRACTOR VERIFY.

23. EXISTING ROOM SIGNAGE.

24. EXISTING CARD READER.

25. REFERENCE DOOR SCHEDULE.

26. PAINT INTERIOR SIDE OF EXISTING WINDOW GLAZING

ONLY "FLAT BLACK".

27. REINSTALLED EXISTING ROOM SIGNAGE.

28. REINSTALLED EXISTING CARD READER.

29. PLASTER ASSEMBLY INFILL AT EXISTING WALL AS

DETAILED AT EXISTING WINDOW OPENING.

30. ENSURE EXISTING WALL VENT IS SECURELY CLOSED

SHUT PRIOR TO COVER-UP.

31. PROVIDE WALL PROTECTION TO MATCH EXISTING.

32. PROVIDE NEW CEILING AS SCHEDULED.

33. PROVIDE GYPSUM BOARD/STEEL STUD FRAMED

FUR-DOWN AS DETAILED.

34. PROVIDE 2' X 2' RAISED FLOOR SYSTEM AT 10" ABOVE

THE 4TH FLOOR LEVEL.

35. ELECTRICAL CONDUITS AND MECHANICAL PIPING PER

MEP DRAWINGS.

36. PROVIDE 5/8" GYPSUM BOARD WHERE EXISTING TILE

WAINSCOT AND SUBSTRATE WAS REMOVED. TEXTURE

AND FINISH TO MATCH EXISTING ADJACENT WALLS (4'-0"±

HIGH, LOCATE AS INDICATED BY HEAVY LINE).

37. TEXTURE AND FINISH EXISTING GYPSUM BOARD

SUBSTRATE TO MATCH EXISTING ADJACENT WALLS.

38. GYPSUM BOARD ASSEMBLY INFILL AS DETAILED AT

EXISTING WINDOW OPENING.

39. PROVIDE INFILL PER KEYED NOTE 29 AT VOID LEFT BY

HEATER REMOVED.

40. PROVIDE 1" THICK MINIMUM CONCRETE INFILL FLUSH

WITH EXISTING CONCRETE TOPPING WHERE PORTIONS

OF EXISTING CMU WALLS ARE REMOVED.

41. PROVIDE PAINTED WOOD CHAIR RAIL TO MATCH

EXISTING.

42. REINSTALLED EXISTING SHELF.

43. PROVIDE GYPSUM BOARD/METAL STUD FRAMED CHASE

FROM FLOORS ABOVE . MINIMIZE SIZE AND REFERENCE

MEP DRAWINGS FOR COMPONENTS TO BE IN CHASE.

44. RAMP AND RAILS BY RAISED FLOOR SYSTEM

MANUFACTURER.

45. ROOM PERIMETER WALLS TO BE FULLY SEALED TOP

AND BOTTOM ON BOTH SIDES OF WALL. EXTERIOR WALL

SEAL INTERIOR SIDE ONLY.

KEYED NOTES - RENOVATION

46. TEMPORARY ALUMINUM RAMP BY CONTRACTOR TO BE

RETURNED TO OWNER AT END OF JOB.

47. MODULAR BRICK INFILL ON EXTERIOR TO MATCH

EXISTING. TOOTH-IN AND MATCH MORTAR.

KEYED NOTES - RENOVATION (CONT.)

EXISTING WALL TO REMAIN

NEW WALL CONSTRUCTION

EXISTING DOOR/FRAME ASSEMBLY

TO REMAIN

EXISTING WINDOW ASSEMBLY

TO REMAIN

NEW WINDOW ASSEMBLY

NEW DOOR/FRAME ASSEMBLY

1 HR. FIRE-RATED WALL (EXISTING)

2 HR. FIRE-RATED WALL (EXISTING)

LEGEND - RENOVATION

FIRE-RATED WALL (NEW OR EXISTING

1 HOUR UNLESS NOTED OTHERWISE)

TRUE NORTH PLAN

NORTH

ROOM

EXIST. ELEVATOR

MACHINE ROOM

EXIST.

CORRIDOR

C*B*2

EXIST.

TELECOM

EXIST.

BREAK ROOM

EXIST.

CORRIDOR

C*B*3

12'-8 5/8"±

12'-2"±

8' -2

/4

15'-7"±

000166

1 TELECOM ROOM 0001 - ROOM RENOVATION

SCALE: 1/4" = 1'-0"

X2

X2X5

X5

2 3

EXIST. ELEVATOR

MACHINE ROOM

EXIST.

CORRIDOR

C*B*2

EXIST.

TELECOM

EXIST.

BREAK ROOM

EXIST.

CORRIDOR

C*B*3

TELECOM

ROOM

2 TELECOM ROOM 0001 - CEILING RENOVATION

SCALE: 1/4" = 1'-0"

OD

Project Number

Building Number

Drawing Number

DrawnCheckedIssue Date

Location

Project Title

21 3 4 5 6 7 8 9 10

21 3 4 5 6 7 8 9 10

B

A

C

D

E

F

B

A

C

D

E

F

PhaseDrawing Title

Approved: Project Director

PROJECT MANAGEMENTCONSULTANTRevisions: Date:

U.S. Department of Veterans Affairs

Construction and Facilities Management

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

FULLY SPRINKLERED

539-21-701

4-MAY-2022

100% CONSTRUCTION

DOCUMENTS

CINCINNATI VAMC EHRM

INFRASTRUCTURE UPGRADES

3200 VINE ST., CINCINNATI, OH

8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com

ETS

T

TA

GE

S

R I

E T E X

FO

T

CE

TI

H

AS

DER CRA

F. BIAN

C

OJO

S

EP

H

7 6 22 1

5/4/22

AS-440-C.2.B

ENLARGED FLOOR PLANS -

BASEMENT FLOOR RENOVATION

IAR

C2

1. REFERENCE GENERAL NOTES ON SHEET GI-004.

2. UNLESS NOTED OTHERWISE, ALL EXISTING WALLS

ARE 5/8" GYPSUM BOARD/3 5/8"METAL STUD FRAMED

TO UNDERSIDE OF PRIMARY BUILDING FRAMING

STRUCTURE (1 HR. FIRE RATED - CONSTRUCTION

SIMILAR TO U.l. DESIGN NO. U465). CONTRACTOR TO

VERIFY.

3. UNLESS NOTED OTHERWISE, ALL EXISTING DOOR

ASSEMBLIES ARE SOLID CORE WOOD DOORS/HOLLOW

METAL FRAME TYPICAL (3'-0" X 7'-0").

4. UNLESS NOTED OTHERWISE ALL EXISTING LAY-IN

CEILING ASSEMBLIES ARE 2' X 2' STANDARD GRID WITH

FISSURED TILES AT 8'-0" A.F.F. TYPICAL.

5. UNLESS NOTED OTHERWISE, ALL EXISTING STEEL

COLUMN FUR-OUTS ARE GYPSUM BOARD/METAL STUD

FRAMED TYPICAL.

6. PARTIAL OR ENTIRE RECONSTRUCTION OF SOME

EXISTING CEILING ASSEMBLIES THOUGH OUT THE

ENTIRE BUILDING(S), ESPECIALLY IN CORRIDORS,

WILL BE NECESSARY. REFERENCE ALL DISCIPLINE

DEMOLITION DRAWINGS. RECONSTRUCTION IS TO

INCLUDE MISCELLANEOUS PATCHING /REPAIR TO

MATCH EXISTING OR BETTER CONDITIONS.

7. EXISTING FIRE-RATED WALL IDENTIFICATION

INDICATED ONLY FOR IMMEDIATE AFFECTED ROOM

WALLS. CONTRACTOR SHALL VERIFY FULL EXTENT OF

EXISTING FIRE-RATED WALLS AT ADJACENT AREAS.

8. ALL NEW WALLS SHALL BE PARTITION TYPE '1' UNLESS

OTHERWISE NOTED.

9. UNLESS NOTED OTHERWISE AT ALL ROOMS WHERE

EXISTING LAY-IN CEILING IS REMOVED AND IS TO

BECOME A "NO CEILING" ROOM, THE EXISTING

GYPSUM BOARD ABOVE PREVIOUSLY REMOVED

CEILING IS TO BE FULLY TAPED, FLOATED, TEXTURED

AND PAINTED TO MATCH EXISTING WALLS.

GENERAL NOTES - RENOVATION

1. EXISTING DOOR/FRAME ASSEMBLY TO REMAIN.

2. PROVIDE CARD READER.

3. PROVIDE ROOM SIGNAGE.

4. PROVIDE NEW FLOORING AND BASE AS SCHEDULED.

5. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE IN THIS ROOM THAT MAY REQUIRE MINOR

DEMOLITION, PATCHING AND REPAIR OF EXISTING

FLOOR SUBSTRATE, WALL OR MISCELLANEOUS

ASSEMBLIES.

6. PROVIDE 8'x4'x3/4" 'AC' FACED FIRE-RATED PLYWOOD

VERTICALLY ON ALL WALLS AS INDICATED. PAINT WITH 2

COATS MIN. FIRE-RATED PAINT. COORDINATE EXACT

LOCATION A.F.F. WITH TECHNOLOGY AND ELECTRICAL

DRAWINGS AND EXISTING CONDITIONS.

7. REFERENCE MEP AND TECHNOLOGY DRAWINGS FOR

WORK SCOPE OF EXISTING AND…