This is a bulk sample analysis report for asbestos testing conducted by Mountain Laboratories for the Mann-Grandstaff VA Medical Center's Café & Kitchen Floors project. The analysis was performed for customer Chris Warner (Customer #1123) located at 4815 N. Assembly Building 32, Spokane, WA 99205, with testing completed on February 20, 2026.
Six samples were analyzed using EPA/600/R-93/116 and 40 CFR Part 763, Subpart E, Appendix E test methods. The samples consisted of floor tiles (samples 1A and 1B), floor grout (samples 2A and 2B), and terrazzo flooring (samples 3A and 3B). All six samples tested negative for asbestos presence, with no detectable asbestos types or percentages (N.D.). The non-fibrous material composition varied by sample type: floor tiles contained 100% other materials with black layers containing 60% quartz and 40% other materials; floor grout samples contained 60% quartz and 40% other materials; and terrazzo samples contained 15% quartz and 85% other materials. The laboratory notes that negative PLM (Polarized Light Microscopy) results should be confirmed with SEM or TEM testing and that sample results cannot be used to claim product certification or endorsement by NVLAP, NIST, or any federal government agency.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C26026R0109 Amendment 0003.docx | DOCX document | |
| 668-25-105 Pre-Bid Site Visit Sign-In Sheet 08-18-26.pdf | ||
| 36C26026R0109 Grease Traps RFI Questions and Answers.pdf | ||
| 36C26026R0109 Amendment 0002.docx | DOCX document | |
| 36C26026R0109 Amendment 0001.docx | DOCX document | |
| Attachment 2 - 668-25-105- Specs.pdf | ||
| 36C26026R0109.docx | DOCX document | |
| Attachment 1 - 668-25-105 - SOW.pdf | ||
| Attachment 9 - VA Site Visit Campus Map - Bldg 5.pdf | ||
| Attachment 6 - 668-25-105 - Price Breakout.xlsx | XLSX spreadsheet | |
| Attachment 4 - 668-25-105 - Past Performance Questionnaire.docx | DOCX document | |
| Attachment 3 - 668-25-105 - Wage Determination Spokane.pdf | ||
| RFP 36C26026R0109.docx | DOCX document | |
| Attachment 8 - VA Specific Special Contract Clause.docx | DOCX document | |
| Attachment 5 - 668-25-105 - Contractor Rules of Behavior.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MOUNTAIN LABORATORIES
BULK SAMPLE ANALYSIS FOR ASBESTOS
Mann- Grandstaff VA Medical Center Project: Café & Kitchen Floors
Chris Warner
4815 N. Assembly Bldg. 32
Spokane, WA 99205
Test Method: 40 CFR, Part 763, Subpart E, Appendix E and EPA/600/R-93/116 Customer #: 1123
Laboratory No. B26-7130 B26-7131 B26-7132
Sample ID No. 1A 1B 2A
Sample Description Floor Tile Floor Tile Floor Grout
Sample Treatment Teased/Crushed Teased/Crushed Teased/Crushed
Homogeneous No No Yes
Layered Yes Yes No
Fibrous No No No
Sample Color Tan/Black Tan/Black Gray
Asbestos Present No No No
Asbestos Type and
Percentage
Tile N.D.
Black Layer N.D.
Tile N.D.
Black Layer N.D.
N.D.
Total % Asbestos None None None
Other Fibrous Material
In Sample
Non-Fibrous Material
Tile:
Other 100%
Black Layer:
Quartz 60%
Other 40%
Tile:
Other 100%
Black Layer:
Other 40%
Quartz 60%
Other 40%
Date Analyzed: February 20, 2026 Analyzed By: Sydney Jeske
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written approval by Mountain Laboratories. Soil/Dust samples are not covered under NVLAP Accreditation.
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
MOUNTAIN LABORATORIES
BULK SAMPLE ANALYSIS FOR ASBESTOS
Mann- Grandstaff VA Medical Center Project: Café & Kitchen Floors
Chris Warner
4815 N. Assembly Bldg. 32
Spokane, WA 99205
Test Method: 40 CFR, Part 763, Subpart E, Appendix E and EPA/600/R-93/116 Customer #: 1123
Laboratory No. B26-7133 B26-7134 B26-7135
Sample ID No. 2B 3A 3B
Sample Description Floor Grout Terrazo Terrazo
Sample Treatment Teased/Crushed Teased/Crushed Teased/Crushed
Homogeneous Yes Yes Yes
Layered No No No
Fibrous No No No
Sample Color Gray Green Green
Asbestos Present No No No
Asbestos Type and
Percentage
N.D. N.D. N.D.
Total % Asbestos None None None
Other Fibrous Material
In Sample
Non-Fibrous Material
Other 40%
Quartz 15%
Oher 85%
Quartz 15%
Oher 85% Date Analyzed: February 20, 2026 Analyzed By: Sydney Jeske
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written approval by Mountain Laboratories. Soil/Dust samples are not covered under NVLAP Accreditation.
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
File details come from the government source that posted it. Updated .