Attachment 6 - E. EHRM Infrastructure Addendum 1 - Part 2 of 2.pdf
PDF 9 MB Posted
- Attached to
- 36C77623B0063 - EHRM Infrastructure System Upgrades, Chicago, IL - Solicitation Federal contract opportunity
- Solicitation number
- 36C77623B0063
About this file
This is a solicitation for infrastructure system upgrades at the Captain James A. Lovell Federal Health Care Center campus in Chicago, Illinois. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas. Key work includes mechanical, electrical, telecommunications, and fire protection upgrades. The solicitation includes architectural drawings, mechanical plans, electrical plans, and fire protection drawings depicting the scope of work. Bids are due by July 14, 2023 with award anticipated by August 4, 2023. The set-aside category is unspecified.
View the file
Other files for this federal contract opportunity
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MECHANICAL
ROOM
B103
STORAGE
ROOM
B104
ELEV
BELEV1
STAIRS
BST3
MECHANICAL
ROOM
B101
MECH
ROOM
B102
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
3/8/23
1017.A-101
BASEMENT FLOOR PLAN
SFTM
SCALE: 1/8" = 1'-0"
BASEMENT FLOOR PLAN -B1017F4 0' 4' 8' 16' 32'
1/8"=1'-0"
0' 2' 4' 8' 16'
1/4"=1'-0"
NO ARCHITECTURAL
WORK ON THIS FLOOR
"FOR CONTRACTOR
REFERENCE ONLY"
NORTH
FULLY SPRINKLERED
STAIRS
1ST4
STERILE
STORAGE
1076A
STAFF
LOUNGE
CORRIDOR
IRM ADMIN
OFFICE
ADMIN OFFICE
RECORDS
OFFICE
SUPPLY
CORRIDOR
CORRIDOR
OFFICE
TLT
SOIL
UTIL
DUTY
ROOM
DIAGNOSIS
ORAL
TLT
1083A
TLT
DIAGNOSIS
ORAL
DIAGNOSIS
ORAL
DIAGNOSIS
ORAL
WAITING
AREA
DARK ROOM
1085A
DENTAL
X-RAY
OFFICE
ELEC
CLO
COMM
CLO
STAFF
LOUNGE
CORRIDOR
CORRIDOR
OFFICE
SUPPLY
SUPPLY
OFFICE
1094B
OFFICE
1094A
OFFICE
OFFICE
VEST
CORRIDOR
CORRIDOR
JAN
STO
OFFICE
OFFICE
OFFICE
STAFF
LOUNGE
VEST
FEMALE
TOILET
MALE
TOILET
BIOMED
WORKSHOP
LOUNGE
TOILET
STAIRS
1ST5
RECEPTION/
RECORDS
RECEIVING
RECEPTION
CORRIDOR
VENDING
VESTIBULE
ELEVATOR
LOBBY
ELEV
1ELEV1
ELEV
1ELEV2
STAIRS
1ST3
CORRIDOR
1ELEV2
JAN
ENDO
SUPPLY
SUPPLY
SOIL
UTIL
SUPPLY
1007A
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
CORRIDOR
CORRIDOR
COMPUTER
ROOM
MALE
LOCKERS
MALE
TOILET
1009A
F TLT
1009B
ENDO
DTR
ENDO
DTR
ENDO
DTR
ENDO
DTR
ENDO
DTR
WAITING
AREA
VESTIBULE
OFFICE
OFFICE
OFFICE
TOILET
1016A
RECEPTION/
ADMIN
ENDO
SUPPLY
1029A
MALE
TOILET
M
TOILET
1022A
F LOCKER
F TLT
1020A
STAIRS
1ST2
STAIRS
1ST1
ENDO
DTR
ENDO
DTR
ENDO
DTR
ENDO
DTR
ENDO
DTR
GEAR
LOCKER
ENDO
STERILE
SUPPLY
VESTIBULE
CORRIDOR
STAFF
LOUNGE
ELEC
CLO
COMM
CLO
STAFF
LOUNGE
CORRIDOR
COMPUTER
ROOM
ELEC
CLO
COMM
CLO
STAFF
LOUNGE
CORRIDOR
COMPUTER
ROOM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
3/8/23
1017.A-102
FIRST FLOOR PLAN
SFTM
SCALE: 1/8" = 1'-0"
FIRST FLOOR PLAN - NORTH -B1017F4 SCALE: 1/8" = 1'-0"
FIRST FLOOR PLAN - SOUTH -B1017F7 0' 4' 8' 16' 32'
1/8"=1'-0"
0' 2' 4' 8' 16'
1/4"=1'-0"
SCALE: 1/4"=1'-0"
EXISTING TR - 1012 - DEMO PLANC9
SCALE: 1/4"=1'-0"
EXISTING TR - 1087 - DEMO PLANB2
SCALE: 1/4"=1'-0"
TR - 1087 - REMODEL PLANC2
SCALE: 1/4"=1'-0"
TR - 1012 - REMODEL PLAND9
1017.A-102 C9&D9
1017.A-102 B2&C2
NO ARCHITECTURAL
WORK IN THIS ROOM
"FOR CONTRACTOR
REFERENCE ONLY"
NO ARCHITECTURAL
WORK IN THIS ROOM
"FOR CONTRACTOR
REFERENCE ONLY"
NORTH
FULLY SPRINKLERED
KEY PLAN
F4 F7
15 15
STAIRS
2ST3
WAITING
ROOM
ELEVATOR
LOBBY
ELEV
2ELEV2
ELEV
2ELEV1
POST OP
DOR
DOR
DOR
DOR
DOR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
FLAMMABLE
STORAGE
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
WORK
ROOM
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
OFFICE
OFFICE
OFFICE
WAITING
WAITING
AREA
WAITING
AREA
CORRIDOR
CORRIDOR
CORRIDOR
STAFF
LOUNGE
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
RESTORATIVE
DTR
PHARMACY
DECONTAMINATION
CSR
CLEAN
CSR
STERILE
CSR
CORRIDOR
SCRUB/
SUPPLY
SOIL
UTILITY
TOILET
SUPPLY
SUPPLY
ADMINISTRATIVE
OFFICE
JAN
MALE
TOILET
FEMALE
TOILET
STERILE
SUPPLY
WAITING
AREA
RECRUIT
F TOILET
ELEC
CLO
DOCTOR
OFFICE/LOUNGE
COMM
CLO
SUPPLY
OFFICE
OFFICE
TOILET
TOILET
CORRIDOR
CORRIDOR
STAIRS
2ST4
CORRIDOR
RECRUIT
M TOILET
MALE
TOILET
FEMALE
TOILET
RESTORATIVE
DTR
RESTORATIVE
DTR
STAIRS
2ST5
TR
OFFICE
2030A
SEDATION
RECOVERY
IV
SEDATION
OFFICE
SEDATION
RECOVERY
OFFICE
DOR/
SEDATION
DOR/
SEDATION
DOR/
SEDATION
DOR
DOR
STERILE
SUPPLY
OFFICE
DOR
DOR
DOR
DOR
DOR
DOR
DOR
DOR
DOR
DOR
SUPPLY
DOR
DOR
DOR
DOR
STAIRS
2ST1
CORRIDOR
CORRIDOR
CORRIDOR
STAFF
LOUNGE
BIO HAZ
RECRUIT
LOUNGE
F TLT/
LOCKER
2017A
VESTIBULE
GR LKR
RECEP/
WAITING
2015STAIRS
2ST2
ADMINISTRATIVE
OFFICE
OFFICE
STRLZR
CLEAN
CSR
DECON
CSR
WORK
ROOM
STORAGE
BULK
STORAGE
GR LKR
CORRIDOR
2ELEV2
ELEC
CLO
COMM
CLO
ELEC
CLO
COMM
CLO
TR
SUPPLY
15 15
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
3/8/23
1017.A-103
SECOND FLOOR PLAN
SFTM
SCALE: 1/8" = 1'-0"
SECOND FLOOR PLAN - NORTH -B1017F4 SCALE: 1/8" = 1'-0"
SECOND FLOOR PLAN - SOUTH -B1017F7 0' 4' 8' 16' 32'
1/8"=1'-0"
0' 2' 4' 8' 16'
1/4"=1'-0"
SCALE: 1/4"=1'-0"
EXISTING TR - 2112 - DEMO PLANC1 SCALE: 1/4"=1'-0"
TR - 2112 - REMODEL PLANC3
SCALE: 1/4"=1'-0"
TR - 2123 - REMODEL PLANB3SCALE: 1/4"=1'-0"
EXISTING TR - 2123 - DEMO PLANB1
REMODEL KEYED NOTES
DEMOLITION NOTES
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET ARCHITECTURAL GENERAL NOTES
30 M SMOKE ZONE BARRIER
1 HR FIRE BARRIER
2 HOUR FIRE BARRIER
SMOKE RESISTIVE HAZARDOUS ENCLOSURE
30 M SMOKE ZONE BARRIER - EXISTING
1 HR FIRE BARRIER - EXISTING
2 HOUR FIRE BARRIER - EXISTING
SMOKE RESISTIVE HAZARDOUS ENCLOSURE
- EXISTING
FIRE EXTINGUISHER CABINET - NEW
FIRE EXTINGUISHER CABINET - EXISTING
FIRE RATED WALL LEGEND
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
1017.A-103 C1&C3
1017.A-103 B1&B3
6ALL WALLS
NO ARCHITECTURAL
WORK IN THIS ROOM
"FOR CONTRACTOR
REFERENCE ONLY"
NO ARCHITECTURAL
WORK IN THIS ROOM
"FOR CONTRACTOR
REFERENCE ONLY"
NORTH
4 5
4 5
FULLY SPRINKLERED
KEY PLAN
F4 F7
1 1
PERIO
DTR
PERIO
DTR
PERIO
DTR
PERIO
DTR
PERIO
DTR
PERIO
DTR
PERIO
DTR
PERIO
DTR
PERIO
DTR
PERIO
DTR
PERIO
DTR
PERIO
DTR
PERIO
DTR
OFFICE
3021A
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
3046A
OFFICE
WAITING
ROOM
STAIRS
3ST3
STAFF
LOUNGE
STERILE
SUPPLY
ELEV
3ELEV2
ELEVATOR
LOBBY
ELEV
3ELEV1
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
BMS/SAFETY
OFFICE
JANITOR
CLOSET
RECRUIT
TOILET
PERIO
RECEPTION
PERIO
SUPPLY
CONFERENCE
ROOM
MECHANICAL
ROOM
A/V
STORAGE
STAIRS
3ST5
STAIRS
3ST4
CORRIDOR
VEST
VEST
CORRIDOR
MALE
LOCKERS
3013B
MALE
TLT/SHWR
3013A
FEMALE
TLT/SHWR
3009A
FEMALE
LOCKERS
3009B
ADMIN/LOUNGE
/CONFERENCE
CORRIDOR
ADMINISTRATIVE
OFFICE
OFFICE
PERIO
GEAR LKR
ELEC
CLO
TR
CONFERENCE
ROOM
STAFF
TOILET
STAFF
TOILET
PROS
DTR
PROS
DTR
SOILED
UTILITY
PROS
LAB
OFFICE
OFFICE
OFFICE
PERIO
GEAR
LKR
ELEC
CLO
TR
OFFICE
OFFICE
PERIO
GEAR
LKR
ELEC
CLO
TR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
3/8/23
1017.A-104
THIRD FLOOR PLAN
SFTM
SCALE: 1/8" = 1'-0"
THIRD FLOOR PLAN -B1017F4 0' 4' 8' 16' 32'
1/8"=1'-0"
0' 2' 4' 8' 16'
1/4"=1'-0"
SCALE: 1/4"=1'-0"
TR - 3036 - REMODEL PLAND7
SCALE: 1/4"=1'-0"
EXISTING TR - 3036 - DEMO PLANB7
REMODEL KEYED NOTES
DEMOLITION NOTES
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET ARCHITECTURAL GENERAL NOTES
30 M SMOKE ZONE BARRIER
1 HR FIRE BARRIER
2 HOUR FIRE BARRIER
SMOKE RESISTIVE HAZARDOUS ENCLOSURE
30 M SMOKE ZONE BARRIER - EXISTING
1 HR FIRE BARRIER - EXISTING
2 HOUR FIRE BARRIER - EXISTING
SMOKE RESISTIVE HAZARDOUS ENCLOSURE
- EXISTING
FIRE EXTINGUISHER CABINET - NEW
FIRE EXTINGUISHER CABINET - EXISTING
FIRE RATED WALL LEGEND
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
6ALL WALLS
4 5
11017.A-104 B7&D7
NORTH
FULLY SPRINKLERED
Second Floor 110' - 6"
First Floor 100' - 0"
Third Floor 122' - 0"
Roof Structure 133' - 6"
COMPUTER
ROOM
COMPUTER
ROOM
TR
TR
TR
TR
EXIST. CONCRETE FLOOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
3/8/23
1017.A-301
SECTIONS AND DETAILS
SFTM
0' 2' 4' 8' 16'
1/4"=1'-0"
SCALE: 1/4"=1'-0"
BUILDING SECTION -B1017B1
REMODEL KEYED NOTES
DEMOLITION NOTES
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
SCALE: 1/4"=1'-0"
BUILDING SECTION -B1017B3
EXIST. STUD WALLS
EXIST. FLOOR STRUCTURE
EXIST. CEILING
EXIST. CONCRETE FLOOR
EXIST. STUD WALLS
EXIST. FLOOR STRUCTURE
EXIST. CEILING
EXIST. ROOF STRUCTURE EXIST. ROOF STRUCTURE
6 ALL WALLS
EXIST. STUD WALLS
EXIST. CEILING
5 ALL WALLS
6ALL WALLS
5ALL WALLS
4ALL WALLS
6ALL WALLS
4 ALL WALLS
12 EXIST. FLOOR STRUCTURE
6 ALL WALLS
EXIST. STUD WALLS
EXIST. CEILING
5 ALL WALLS
4 ALL WALLS
FULLY SPRINKLERED
COMM
A/V ROOM
RECORDS
F TLT
M TLT
VESTIBULE
OFFICE
OFFICE
OFFICE
DTR
DENTAL
X-RAY
OFFICE
SUPPLY/
PREP RM
DENTAL
X-RAY
DENTAL
X-RAY
DENTAL
X-RAY
SUCTION
OFFICE
1055A
OPTICAL
LABORATORY
CLEAN
UTILITY
MECHANICAL
ROOM
MECH
LOUNGE
OFFICE
FEMALE
LOCKERS
RECORDS
VEST
MALE
LOCKERS
FEMALE
LOCKERS
ADMINISTRATIVE
OFFICE
M TLT
F TLT
KITCHEN
CORRIDOR
CORRIDOR
CORRIDOR
OLD
PROCEDURE
NOW OFFICE
OFFICE
XRAY
XRAY
XRAY
DTR
DTR
DTR
DTR
DTR
DTR
DTR
DTR
DTR
DTR
CORRIDOR
CORRIDOR
CORRIDOR
STAGING
AREA
SOIL
UTILITY
STER
SUPP
1003A
SUPP
STAGING
X-RAY
CORRIDOR
CORRIDOR
RECEPTION
SUPP
1039JAN
VESTIBULE
STAGING
AREA
SUPPLY
MECH
F. TLT
M. TLT
TR
TR
COMM
COMM
A/V
ROOM
A/V
ROOM
OLD
PROCEDURE
NOW
OFFICE
CORRIDOR
MECH
CORRIDOR
MECH
TR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
C O
L
O
R
A
D
O
L
I
C
E
N
S
E
D
A
R
C
H
I T
E
C
T
S E A
N
M
F
IT
Z
P
A
T
R
I C K
3/8/23
1523.A-101
FIRST FLOOR PLAN - NORTH
SFTM
SCALE: 1/8" = 1'-0"
FIRST FLOOR PLAN - NORTH -B1523
F5
SCALE: 1/4" = 1'-0"
EXISTING TR - 1011 - DEMO PLAN
B2
0' 4' 8' 16' 32'
1/8"=1'-0"
0' 2' 4' 8' 16'
1/4"=1'-0"
SCALE: 1/4" = 1'-0"
TR - 1011 - REMODEL PLAN
B4
SCALE: 1/4" = 1'-0"
EXISTING TR - 1061 - DEMO PLAN
D2
SCALE: 1/4" = 1'-0"
TR - 1061 - REMODEL PLAN
D4
SCALE: 1/4" = 1'-0"
EXISTING TR - 1030 - DEMO PLAN
F2
SCALE: 1/4" = 1'-0"
TR - 1030 - REMODEL PLAN
F4
1. NEW 45-MINUTE-RATED WOOD DOOR W/ HM FRAME. - SEE
DOOR SCHEDULE
2. NEW GWB/METAL STUD 1 HR FIRE WALL, EXTEND TO BOTTOM
OF STRUCTURE OR HARDPAN CEILING. FIRESTOP ALL
PENETRATIONS.
3. INFILL OPENING TO MATCH EXIST WALL CONSTRUCTION.
4. EXISTING WALL –REPAIR ALL EXISTING HOLES IN SHEETROCK
AND FIRE CAULK ALL EXISTING PENETRATIONS TO MAKE INTO
A 1-HR FIRE WALL.
5. EXTEND EXISTING WALL UP TO B.O. STRUCTURE. NEW WALL
EXTENSION TO BE 1 HR. FIRE WALL.
6. LINE FULL LENGTH OF WALL WITH 3/4" FIRE-RETARDANT
PLYWOOD BACKERBOARD PANELS 4'W X 8'H.; MOUNT
PLYWOOD 12" ABOVE FINISH FLOOR TO ALLOW FOR
INSTALLATION OF RESILIENT BASE. PAINT PANELS FIRE
RESISTANT PAINT, HIGH-GLOSS WHITE - 2 COATS. LEAVE
STICKERS UNPAINTED OR REMOVE AND REAPPLY TO
CLEARLY INDICATE FIRE RATING. PAINT ALL REMAINING
WALLS AROUND AND ABOVE PLYWOOD.
7. ACCESS CONTROL, COORDINATE WITH TECHNOLOGY.
8. NOT USED
9. NOT USED
10. SERVER RACK - SEE TELECOM DWGS
11. COMPUTER ROOM A/C UNIT - SEE MECHANICAL DWGS.
12. NEW STATIC-DISSIPATIVE VINYL TILE FLOORING TO MEET ISTS
4.1.1 AND 4" RESILIENT BASE - SEE ROOM FINISH SCHEDULE
13. NOT USED
14. REPAIR/PAINT FLOORS AND WALLS AS REQUIRED AFTER
REMOVAL OF TECHNOLOGY EQUIPMENT.
15. WATERPROOF WALL PER DETAIL B1/A-301.
16. RELOCATED DRINKING FOUNTAIN, SEE MECHANICAL DWGS.
17. FILL REMOVED FLOOR TRENCH WITH CONCRETE AND LEVEL
WITH FLOOR AS REQUIRED FOR INSTALLATION OF NEW
FLOORING.
18. INSTALL NEW FIRE EXTINGUISHER CABINET.
REMODEL KEYED NOTES
1. REMOVE EXIST DOOR/FRAME/HW - PREP FOR NEW
DOOR/FRAME OR INFILL TO MATCH EXIST. WALL CONST - SEE
RENOVATION PLAN & DOOR SCHEDULE.
2. REMOVE EXIST DOOR LEAF/HW - EXIST. FRAME TO REMAIN
PREP - SEE RENOVATION PLAN.
3. DEMO PORTION OF EXIST. WALL FOR NEW DOOR OPENING -
SEE RENOVATION PLAN.
4. REMOVE EXISTING SUSPENDED ACOUSTICAL CEILING
ASSEMBLY IN ITS ENTIRETY
5. REMOVE EXIST. FINISH FLOORING AND 4" RESILIENT BASE.
PREP EXPOSED SUBSTRATE FOR NEW STATIC-DISSIPATIVE
TILE, SDT
6. NOT USED
7. DEMO EXIST. WALL - PATCH FLOOR AND WALLS AS REQ'D
FOR NEW FINISHES
8. REMOVE EXIST. WALL-MOUNTED PLYWOOD AND EQUIPMENT -
SEE TECHNOLOGY DWGS. FOR EQUIPMENT DEMO.
9. EXIST. ACCESS CONTROL - SEE TECHNOLOGY DWGS. FOR
RELOCATION AND REPLACEMENT
10. EXISTING EQUIPMENT RACK - SEE TECHNOLOGY DWGS. FOR
DEMO.
11. NOT USED
12. REMOVE EXIST. PLUMBING FIXTURE, SEE MECHANICAL.
13. REMOVE EXIST. COUNTERTOP.
14. REMOVE EXIST. OVERHEAD COILING DOOR AND ALL
ASSOCIATED TRACKS, HARDWARE, ETC.
15. REMOVE EXIST. GYPSUM BOARD CEILING IN ITS ENTIRETY.
16. REMOVE EXIST. ALUMINUM FLOOR TRENCH AND PREP FOR
INFILL. SEE MECH AND ELEC DRAWINGS FOR REMOVAL OF
UTILITIES FROM FLOOR TRENCH.
DEMOLITION NOTES
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
ARCHITECTURAL GENERAL NOTES
1. EXISTING STRUCTURAL GRIDS, BEAMS AND COLUMNS SHOWN
ARE FOR COORDINATION AND ORIENTATION PURPOSES ONLY
AND NOT FOR ACTUAL LOCATIONS OR SIZE OF COMPONENTS.
THE CONTRACTOR IS TO FIELD VERIFY LOCATIONS OF
COLUMNS AND STRUCTURAL MEMBERS / ELEMENTS.
2. THE AREAS OF WORK SHOWN ARE ASSOCIATED WITH AN
OPERATING FACILITY THAT MUST REMAIN IN SERVICE
24-HOURS A DAY, 7-DAYS A WEEK.
3. SCHEDULE WORK TO MINIMIZE DISRUPTION OF SERVICES.
4. COORDINATE WORK SCHEDULE WITH THE CONTRACTING
OFFICER'S REPRESENTATIVE (COR).
5. COORDINATE WORK WITH ALL OTHER TRADES. VERIFY ALL
EXISTING CONDITIONS PRIOR TO BEGINNING WORK TO
CONFIRM ACCURACY IN THE DRAWINGS. REPORT ANY
DISCREPANCIES TO THE VA COR.
6. DO NOT SCALE THE DRAWINGS. FIELD VERIFY ALL
DIMENSIONS AND EXISTING ARCHITECTURAL AND
STRUCTURAL CONDITIONS.
7. PROVIDE SMOOTH, LEVEL TRANSITIONS FROM NEW FINISH TO
EXISTING FINISH TO REMAIN.
8. GENERAL CONTRACTOR TO PROVIDE AND INSTALL ALL NEW
FINISHES TO COMPLETE THE WORK AS NECESSARY.
9. REMOVE AND REPLACE ELECTRICAL / DATA PLATES, BOXES,
LIGHTS AND ACCESSORIES AS NECESSARY. ADJUST
ELECTRICAL / DATA COMPONENTS AS NECESSARY.
10. PROTECT ADJACENT SURFACES TO REMAIN PRIOR TO
CONSTRUCTION. ANY DAMAGE MUST BE FIXED AT THE
CONTRACTORS EXPENSE.
11. THE GENERAL CONTRACTOR SHALL PROVIDE ICRA DUST
PARTITIONS PER INFECTION CONTROL AND ENVIRONMENTAL
PLANS, AND COORDINATED WITH THE COR PRIOR TO
CLOSING OFF AREAS OF WORK FROM ACTIVE AREAS OF THE
BUILDING.
12. ALL WALLS ARE DIMENSIONED TO FACE OF STUDS, UNLESS
NOTED OTHERWISE.
13. REFER TO MECHANICAL DRAWINGS FOR NEW MECHANICAL
UNITS AND WORK IN ROOMS.
14. REFER TO ELECTRICAL DRAWINGS FOR LIGHTING LOCATIONS
AND WORK IN ROOMS.
15. REFER TO TECHNOLOGY / TELECOM DRAWINGS FOR
TELECOM AND SERVER RACKS, CABLE TRAYS, CABLE JACK
LOCATIONS AND ITEMS RELATED TO TELECOM WORK.
16. REFER TO HAZARDOUS MATERIALS SPECIFICATIONS AND
NOTES ON ENVIRONMENTAL DRAWINGS FOR ABATEMENT
PROCEDURES OF HAZARDOUS MATERIALS.
17. EXISTING AND NEW CABLE TRAYS NOT SHOWN FOR CLARITY
OF ARCHITECTURAL SCOPE OF WORK. REFER TO
TECHNOLOGY / TELECOM DRAWINGS FOR INFORMATION
RELATED TO THESE ITEMS.
18. REFERENCE TECHNOLOGY / TELECOM DRAWINGS FOR
AREAS WHERE NEW DATA JACK WALL OUTLETS WILL BE
PROVIDED IN ROOMS OUTSIDE OF THE TELECOM ROOMS.
PATCH AND PAINT AROUND DATA JACK WALL OUTLET AS
NEEDED. COORDINATE PAINT COLOR WITH EXISTING WALL
COLOR AND VA COR.
19. FIRE-AND SMOKE-SEAL ALL THROUGH-WALL PENETRATIONS
TO COMPLY WITH FIRE-SMOKE RATING APPLICABLE TO WALL.
PROVIDE A MINIMUM OF 1-HOUR FIRE-SMOKE RATING WHERE
WALL RATING IS NOT SHOWN.
20. ALL HOLES THAT ARE LEFT IN ANY WALL AFTER REMOVAL OF
DUCTWORK, PLUMBING, ELECTRICAL, TECHNOLOGY, ETC.
MUST BE REPAIRED WITH GYPSUM BOARD AND TAPE OR
FILLED WITH FIRE CAULKING.
30 M SMOKE ZONE BARRIER
1 HR FIRE BARRIER
2 HOUR FIRE BARRIER
SMOKE RESISTIVE HAZARDOUS ENCLOSURE
30 M SMOKE ZONE BARRIER - EXISTING
1 HR FIRE BARRIER - EXISTING
2 HOUR FIRE BARRIER - EXISTING
SMOKE RESISTIVE HAZARDOUS ENCLOSURE
- EXISTING
FIRE EXTINGUISHER CABINET - NEW
FIRE EXTINGUISHER CABINET - EXISTING
FIRE RATED WALL LEGEND
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
1523.A-101
F2&F4
A-101
1523.B2&B4
1523.A-101
D2&D4
6ALL WALLS
B3
1523.A-301
B1
1523.A-301
NO ARCHITECTURAL
WORK IN THIS ROOM
"FOR CONTRACTOR
REFERENCE ONLY"
NO ARCHITECTURAL
WORK IN THIS ROOM
"FOR CONTRACTOR
REFERENCE ONLY"
NO ARCHITECTURAL
WORK IN THIS ROOM
"FOR CONTRACTOR
REFERENCE ONLY"
NO ARCHITECTURAL
WORK IN THIS ROOM
"FOR CONTRACTOR
REFERENCE ONLY"
NORTH
4 5
ALL WALLS
NON-SPRINKLERED
KEY PLAN
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
EM-LTG
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
LL1
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
LH1
AutoCAD SHX Text T
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text
MDS
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
PP-NN
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
LL2A
AutoCAD SHX Text
LL2
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
LH2
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-121)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-713)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-725)
AutoCAD SHX Text D
AutoCAD SHX Text
VFD
AutoCAD SHX Text
VFD
AutoCAD SHX Text
VFD
AutoCAD SHX Text
(VFD-
AutoCAD SHX Text 525)
AutoCAD SHX Text
VFD
AutoCAD SHX Text
(VFD-
AutoCAD SHX Text 885)
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-845)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-893)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-941)
AutoCAD SHX Text
(PNL-237)
AutoCAD SHX Text
SWITCHGEAR
AutoCAD SHX Text
(TDT-317)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-681)
AutoCAD SHX Text T
AutoCAD SHX Text
(TDT-681)
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
LL1A
AutoCAD SHX Text
(PNL-133)
AutoCAD SHX Text
400A DIST
AutoCAD SHX Text T
AutoCAD SHX Text
(TDT-417)
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -473) http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html AutoCAD SHX Text
MDS
AutoCAD SHX Text
VFD
AutoCAD SHX Text
(TDT-681)
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
LL1A
AutoCAD SHX Text
400A DIST
http://www.2learncad.com/free_cad_blocks.html AutoCAD SHX Text
MDS
AutoCAD SHX Text
VFD
AutoCAD SHX Text
(TDT-681)
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
LL1A
AutoCAD SHX Text
400A DIST
http://www.2learncad.com/free_cad_blocks.html AutoCAD SHX Text
E-PNL
http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html AutoCAD SHX Text
E-PNL
http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html AutoCAD SHX Text Z
AutoCAD SHX Text Z
AutoCAD SHX Text Z
AutoCAD SHX Text Z
AutoCAD SHX Text Z
AutoCAD SHX Text Z
AutoCAD SHX Text Z
AutoCAD SHX Text Z
AutoCAD SHX Text B
AutoCAD SHX Text Z
AutoCAD SHX Text Z
AutoCAD SHX Text Z
AutoCAD SHX Text Z
AutoCAD SHX Text T
AutoCAD SHX Text D
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text Z
AutoCAD SHX Text T
AutoCAD SHX Text T-1
AutoCAD SHX Text
AutoCAD SHX Text
1LP1
AutoCAD SHX Text
AutoCAD SHX Text
1LP2
AutoCAD SHX Text
AutoCAD SHX Text
1LP3
AutoCAD SHX Text
AutoCAD SHX Text
1LP5
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
AutoCAD SHX Text
1LP4
AutoCAD SHX Text
AutoCAD SHX Text
1HP1
AutoCAD SHX Text
AutoCAD SHX Text
1HP2
AutoCAD SHX Text
1LP6
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
PP-N
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
EM-LTG
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
LL1
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
LH1
AutoCAD SHX Text
OS
AutoCAD SHX Text
OS
AutoCAD SHX Text T
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text
MDS
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
PP-NN
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
LL2A
AutoCAD SHX Text
LL2
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
LH2
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-282)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-382)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-982)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-154)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-210)
AutoCAD SHX Text P-6
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -458)
AutoCAD SHX Text P-7
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -378)
AutoCAD SHX Text
EF7
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -530)
AutoCAD SHX Text
EF4
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -190)
AutoCAD SHX Text
EF5
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -846)
AutoCAD SHX Text
EF1
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -534)
AutoCAD SHX Text
TE-3
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -338)
AutoCAD SHX Text
TE-4
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -690)
AutoCAD SHX Text
TE-5
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -950)
AutoCAD SHX Text P-8
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -398)
AutoCAD SHX Text P-9
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -526)
AutoCAD SHX Text
VFD
AutoCAD SHX Text
(VFD-
AutoCAD SHX Text 186)
AutoCAD SHX Text
VFD
AutoCAD SHX Text
(VFD-
AutoCAD SHX Text 910)
AutoCAD SHX Text
VFD
AutoCAD SHX Text
(VFD-
AutoCAD SHX Text 430)
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -606)
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -570)
AutoCAD SHX Text
(PNL-378)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-121)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-713)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-725)
AutoCAD SHX Text D
AutoCAD SHX Text
VFD
AutoCAD SHX Text
VFD
AutoCAD SHX Text
VFD
AutoCAD SHX Text
(VFD-
AutoCAD SHX Text 525)
AutoCAD SHX Text
VFD
AutoCAD SHX Text
(VFD-
AutoCAD SHX Text 885)
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-845)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-893)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-941)
AutoCAD SHX Text
(PNL-237)
AutoCAD SHX Text
SWITCHGEAR
AutoCAD SHX Text
(TDT-317)
AutoCAD SHX Text D
AutoCAD SHX Text
(DS-681)
AutoCAD SHX Text T
AutoCAD SHX Text
(TDT-681)
AutoCAD SHX Text
E-PNL
AutoCAD SHX Text
LL1A
AutoCAD SHX Text
(PNL-133)
AutoCAD SHX Text
400A DIST
AutoCAD SHX Text
(MDP-457)
AutoCAD SHX Text
MDP
AutoCAD SHX Text
LMDP1
AutoCAD SHX Text
(DP-369)
AutoCAD SHX Text
DP
AutoCAD SHX Text
(TDT-169)
AutoCAD SHX Text
(PNL-717)
AutoCAD SHX Text
(PNL-873)
AutoCAD SHX Text
(PNL-662)
AutoCAD SHX Text
(PNL-497)
AutoCAD SHX Text
(PNL-917)
AutoCAD SHX Text
(PNL-365)
AutoCAD SHX Text
(PNL-185)
AutoCAD SHX Text
(PNL-189)
AutoCAD SHX Text
(DS-
AutoCAD SHX Text 165)
AutoCAD SHX Text T
AutoCAD SHX Text
(TDT-417)
AutoCAD SHX Text
(MSDS
AutoCAD SHX Text -473)
AutoCAD SHX Text 00404366
TR
A/V ROOM
CORR
VEST
OFFICE
GYM
LOUNGE
OFFICE
OFFICE
EXAM
ROOM
OBSERVATION
AREA
EXAM
ROOM
EXAM
ROOM
CORRIDOR
FEMALE
LOCKERS
WAITING/
CHECK-IN
CORRIDOR
CORRIDOR
CORRIDOR
OPEN
OFFICE
CLEAN
ROOM
1080MALE
LOCKERS
M TLT
DPT.
HEAD
1070A
F TLT
1081A
VEST
LABORATORY
OFFICE
MECHANICAL
ROOM
COMM
LAB
RECEP
MECH
SHOT
LINE
CLASSROOM
BICILLIAN
BLOOD
DRAW
BIOHAZ
1089A
TLT
STAGING
CLINICAL
RECEP
SHOT
LINE
CORRIDOR
ELECTRICAL
RECORDS
STAGING
AREA
CLASSROOM
M TLT
OFFICE
F TLT
OFFICE
WAITING
ROOM
OFFICE
OFFICE
OFFICE
EXAM
ROOM
EXAM
ROOM
FITTING
OFFICE/
EXAM
OFFICE/
EXAM
OFFICE/
EXAM
FUNDUS
ROOM
JAN
1103TLT
VESTIBULE
WAIT
AREA
RECEP
CORRIDOR
CORRIDOR
CORRIDOR
VEST
CORRIDOR
AUDIO OFF
AUDIO OFF
OFFICE
OFFICE
OFFICE
TLT
EXAM
ROOM
OFFICE
VEST
EXAM
ROOM
EXAM
ROOM
EXAM
ROOM
EXAM
ROOM
OFFICE
OFFICE
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
EXAM
ROOM
OFFICE
OFFICE
OFFICE
RECEPTION/
ADMIN
WAITING
ROOM
VITALS
JAN
1131A
STORAGE
STAFF
LOUNGE
WAITING
ROOM
OFFICE
OFFICE
TLT
OFFICE
AUDIO BOOTH
EXAM
AUDIO BOOTH
EXAM
AUDIO BOOTH
EXAM
CLEAN
UTILITY
VEST
LPO
1070B
COMM
COMM
TR
RECORDS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
3/8/23
1523.A-102
FIRST FLOOR PLAN - SOUTH
SFTM
SCALE: 1/8" = 1'-0"
FIRST FLOOR PLAN - SOUTH -B1523F5
SCALE: 1/4" = 1'-0"
EXISTING TR - 1097 - DEMO PLANA2
0' 4' 8' 16' 32'
1/8"=1'-0"
0' 2' 4' 8' 16'
1/4"=1'-0"
SCALE: 1/4" = 1'-0"
TR - 1097 - REMODEL PLANB2
SCALE: 1/4" = 1'-0"
EXISTING TR - 1064 - DEMO PLAND2
SCALE: 1/4" = 1'-0"
TR - 1064 - REMODEL PLANF2
ALL WALLS
15 5
1523.A-101 D2&D4
1523.A-102 D2&F2
A-102 1523.A2&B2
NO ARCHITECTURAL
WORK IN THIS ROOM
"FOR CONTRACTOR
REFERENCE ONLY"
NO ARCHITECTURAL
WORK IN THIS ROOM
"FOR CONTRACTOR
REFERENCE ONLY"
NORTH
8" CMU
8" CMU
4 ALL WALLS5
NON-SPRINKLERED
KEY PLAN
Roof Structure 112' - 0"
First Floor 100' - 0"
Roof Structure 112' - 0"
First Floor 100' - 0"
TR
TR
TR
TR
EXIST. CONCRETE FLOOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
3/8/23
1523.A-301
SECTIONS AND DETAILS
SFTM
0' 2' 4' 8' 16'
1/4"=1'-0"
SCALE: 1/4"=1'-0"
BUILDING SECTION -B1523B1
6 ALL WALLS
REMODEL KEYED NOTES
DEMOLITION NOTES
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
SCALE: 1/4"=1'-0"
BUILDING SECTION -B1523B3
EXIST. STUD WALLS
EXIST. ROOF STRUCTURE
EXIST. CEILING
5 ALL WALLS
EXIST. CONCRETE FLOOR
6ALL WALLS
EXIST. STUD WALLS
EXIST. ROOF STRUCTURE
EXIST. CEILING
5ALL WALLS
SCALE: 1/4"=1'-0"
BUILDING SECTION -B1523D1 SCALE: 1/4"=1'-0"
BUILDING SECTION -B1523D3
EXIST. CONCRETE FLOOR
6 ALL WALLS
EXIST. CMU WALLS
EXIST. ROOF STRUCTURE
EXIST. CEILING
5 ALL WALLS
EXIST. CONCRETE FLOOR
6ALL WALLS
EXIST. CMU WALLS
EXIST. ROOF STRUCTURE
EXIST. CEILING
5ALL WALLS
4ALL WALLS 4 ALL WALLS
4ALL WALLS 4 ALL WALLS
38" CMU 3 CMU
NON-SPRINKLERED
PIPE, CONDUIT, DUCT,
ETC. SUPPORT EACH
SIDE OF WALL
FIRE SEAL SYSTEM IN
ALL RATED WALLS
PIPING OR ROUND
DUCTWORK
GLASS FIBER BOARD
OR BACKER ROD
DUCT SUPPORT
EACH SIDE OF WALL
FRAME OPENING WITH
STUDSRECTANGULAR
DUCTWORK
FIRE SEAL SYSTEM IN
ALL RATED WALLS
ADJACENT SPACE
W/ WATER
TELECOM
ROOM SIDE
TOP OF SLAB
RESILIENT BASE
NEW FLOORING
CAULK BOTTOM OF ALL
SHEETROCK TO
FLOORING
WATER RESISTANT
GYPSUM BOARD
8" TYP X GYP BOARD ON
SIDE OF STUD
PARTITION TYPE PER
PLANS
COVER OR FACE PLATE
FIRE PUTTY AROUND OUTLET,
EQUIPMENT, AND RECEPTACLES
FIRE CAULKING ALL AROUND AT
FACE PLATE
CONTINUE ACOUSTIC BATT
AROUND AND BEHIND BOX
BOX SIZE VARIES
CONDUIT
DETAILED BELOW
PARTITION TYPE PER
PLANS
COVER OR FACE PLATE
FIRE PUTTY AROUND OUTLET,
EQUIPMENT, AND RECEPTACLES
FIRE CAULKING ALL AROUND AT
FACE PLATE
CONTINUE ACOUSTIC BATT
AROUND AND BEHIND BOX
BOX SIZE VARIES
CONDUIT
R
EQ
. I F
BO
XE
S
AR
E U
N D
ER
4" A
PA
R
T
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
3/8/23
A-301
TYPICAL DETAILS
SFTM
ALL
SCALE: 3"=1'-0"
WALL WATERPROOFING DETAILB1
BUILDING WALL OR FLOOR
NOTE:
ISOLATION ASSEMBLY SHALL
BE DESIGNED TO WITHSTAND
0.5g LATERAL AND VERTICAL
PIPE OR ELECTRICAL CONDUIT
MANUF.
CONSULT
PROVIDE ESCUTCHEON AT
EXTERIOR WALL PENETRATIONS
NOTE:
ROOFING TO MEET SOLAR
REFLECTIVITY INDEX TO MEET ASHRAE
90.1 AND ENERGY STAR
REQUIREMENTS, MINIMUM SRI 82.
6" 6"
10A-501
A7 TYP.
NOTE A1:
PREP, BOND AND / OR FASTEN NEW MEMBRANES TO EXISTING PER
MANUFACTURER'S RECOMMENDATIONS FOR WARRANTY IN PREFERRED
BONDING METHODS MAY VARY BY SYSTEM OR LOCATION.
ROOFING TO MEET SOLAR REFLECTIVITY INDEX TO MEET ASHRAE 90.1 AND
ENERGY STAR REQUIREMENTS, MINIMUM SRI 82.
SE
E
N O
TE
A
SCALE: 3"=1'-0"
PENETRATION FIRESTOPPING DETAILSD1
SCALE: 3"=1'-0"
ROOFING SYSTEM DETAILC9
SCALE: 1 1/2"=1'-0"
ROOF CURB DETAILE9
SCALE: 3"=1'-0"
MECH EQUIPMENT RESTRAINT DETAILB9
SCALE: 1 1/2"=1'-0"
EXTERIOR WALL PENETRATION DETAILF9
SCALE: 3"=1'-0"
TYP BACK BOX FIRE PUTTY DETAILE1
SEAL ALL AROUND WITH
RESILIENT NON-HARDENING
SEALER-TYP
1/2" TO 5/8" ANNULAR
SPACE-PACK SPACE WITH
FIBERGLASS MATERIAL
FILL OPENING WITH GROUT OR
SEALANT DEPENDING UPON
BUILDING MATERIALS PENETRATED
PIPE SLEEVE OR SHEET METAL SLEEVE
CAREFULLY CUT AND REMOVE
PORTION OF EXISTING
ROOFING AS NECESSARY
OPTIONAL METAL FRAMING
FOR HEIGHTS AND WIDTHS
GREATER THAN
FIRE-TREATED BLOCKING
CAN PROVIDE
REPLACE ROOF INSULATION
WHERE REMOVED FOR
INSTALLATION OF CURB
SECURE FIRE-TREATED NAILER
TO FIRE-TREATED BLOCKING
SECURED TO ROOF DECK
EXISTING SINGLE PLY
ROOFING SYSTEM
SEAL ALL SEAMS PER MANUFACTURER
SECURE LEVELED ROOF CURB TO FIRE
TREATED NAILER SECURED TO ROOF DECK
SEAL ALL FASTENERS THROUGH
CAP, SEAL CAP TO CURB
SEISMIC RESTRAINT FOR ROOF
EQUIPMENT
LAP EQUIPMENT PAD AND HORIZONTAL
UNDERLAYMENT MEMBRANE LAYER
OVER CURB FLASHING
LAP VERTICAL CURB FLASHING
MEMBRANE LAYER OVER EXISTING
ROOFING AT ROOF PENETRATION
OVERLAP HORIZONTAL MEMBRANE
LAYER AT BOTTOM OF ROOF CURB
FLASHING
VERIFY COMPOSITION OF EXISTING
ROOF ASSEMBLY, EXISTING
STRUCTURE TO REMAIN
NEW RIGID INSULATION, 3" MINIMUM
APPLY MASTIC OVER INSULATION
FASTENERS
COVER BOARD
CONTINUOUS WEATHER BARRIER
UNDERLAYMENT, WHERE OCCURS
SINGLE PLY ROOFING MEMBRANE
FASTENED OR ADHERED PER
MANUFACTURER
SINGLE PLY FLASHING MEMBRANE
FASTENED OR ADHERED PER
MANUFACTURER
CUT EXISTING ROOFING WHERE
NECESSARY FOR INSTALLATION OF
NEW SYSTEMS
PROVIDE 6" OF OVERLAPPING
MEMBRANE OVER FLASHING
SINGLE PLY ROOFING SYSTEM
FLOOR OR ROOF
RESILIENT PAD DESIGNED FOR 1/4"
MAX. STATIC DEFLECTION
STAINLESS STEEL BONDED PLATE
EQUIPMENT BASE
ANCHOR BOLT OR EXPANSION
ANCHOR
NEOPRENE WASHER AND SLEEVE
MAX. 4" NOMINAL STEEL PIPE SCHEDULE 10 OR GREATER
(MAX. 4" DIAMETER COPPER PIPE)
3/4" FLEXIBLE FOAM PIPE INSULATION
MIN. 1/2" DEPTH INTUMESCENT FIRESTOP SEALANT
(REQUIRED BOTH SIDES OF WALL ASSEMBLY)
MIN. 2 1/2" CONCRETE FLOOR
(MIN. 3" CONCRETE WALL
MIN. 2" MINERAL WOOL TIGHTLY PACKED
MIN. 1/2" FIRESTOP SEALANT BEAD AT ALL
POINTS OF CONTACT
MIN. 4 1/2" CONCRETE FLOOR
(MIN. 5" CONCRETE WALL
MIN. 4" MINERAL WOOL TIGHTLY PACKED
(ANNULAR SPACE = MIN. 11/16" MAX. 3 1/16")
UL C-AJ-5048
INSULATED PIPE PENETRATION THRU SLAB
NOTE:
1. 2HR FIRE-RATING FLOOR SHOWN
2. MAX. DIAMETER OF OPENING = 8"
UL W-L-5028
NOTE:
1. 2 HR FIRE-RATING SHOWN
2. MAX. DIAMETER OF
OPENING = 7 1/2"
INSULATED PIPE PENETRATION THRU PARTITION
MAX. 4" NOMINAL STEEL PIPE
SCHEDULE 40 OR GREATER
(MAX. 2" DIAMETER COPPER
PIPE OR TUBING)
MIN. 1/2" FIRESTOP SEALANT
BEAD AT ALL JOINTS OF CONTACT
GYPSUM WALL ASSEMBLY, FIRE-
RATING AS SCHEDULED
UL C-AJ-5198
NOTE:
1. 2HR FIRE-RATED CONCRETE
FLOOR SHOWN
2. MAX. DIAMETER OF OPENING = 7"
PIPE PENETRATION THRU SLAB
MAX. 2" STEEL PIPE SCHEDULE,
40 OR GREATER
MAX. 1" GLASS FIBER PIPE
INSULATION
MIN. 1/2" DEPTH INTUMESCENT FIRESTOP SEALANT
(REQUIRED BOTH SIDES OF WALL)
@ ALL POINTS OF CONTACT
METAL STUD FRAMING ALL
SIDES OF OPENING
MIN. 5/8" DEPTH INTUMESCENT
FIRESTOP SEALANT
3/4" FLEXIBLE FOAM PIPE
INSULATION
UL C-AJ-1149
MIN. 3" MINERAL WOOL TIGHTLY PACKED
(MAX. 12" DIAMETER OPENING)
NOTE:
1. 2HR FIRE-RATED CONCRETE FLOOR SHOWN
2. MAX. DIAMETER OF OPENING = 12"
3. PIPE OPTION
CAST IRON 10"
COPPER PIPE OR TUBING 4"
MIN. 1/2" FIRESTOP SEALANT BEAD AT ALL
POINTS OF CONTACT (BOTH SIDES OF WALL
ASSEMBLY)
MAX. DIA. PIPE OPTIONS
STEEL CONDUIT
EMT
MAX. DIA.
4" 4"
MAX. 10" DIA. NOMINAL STEEL PIPE
SCHEDULE 10 OR GREATER (SEE NOTE
3 FOR OTHER OPTIONS)
MIN. 1/2" DEPTH INTUMESCENT
FIRESTOP SEALANT
MIN. 4 1/2" CONCRETE FLOOR OR
UL CONCRETE BLOCK WALL
NOTE, ROOF DETAIL LOCATION:
ROOF DETAILS ARE FOR BUILDING 1017 WHERE
THERE ARE 2 MECHANICAL UNITS LOCATED ON THE
ROOF. SEE 1017.M-103 FOR UNIT LOCATION.
SCALE: 3"=1'-0"
BACK TO BACK BOX FIRE PUTTY DETAILE3
SPRAY-APPLIED
FIRE-RESISTIVE
MATERIAL
(SFRM)
CUT ONE LAYER GWB TO
FOLLOW PROFILE OF DECKING.
SEAL CONTINUOUSLY WITH
ACOUSTICAL SEALANT.
ACOUSTICAL SEALANT
SLOTTED TOP
TRACK
STUD
SAB
GWB
CONCRETE SLAB METAL DECK
(PERPENDICULAR TO FLUTES)
METAL DECK
(PARALLEL TO FLUTES)
DETAIL 1B - "SMOKE PARTITIONS AND SOUND-CONTROL WALLS"- ADDITIONAL NOTES:
1. UPGRADE TO DETAIL "1A" WHERE WALL IS DESIGNATED WITH A FIRE-RESISTANCE RATING.
2. FILL VOIDS WITH SOUND ATTENUATION BATTS (SAB).
3. SOUND WALLS AND SMOKE PARTITIONS REQUIRE THAT AT LEAST ONE LAYER OF GWB BE CUT TO FOLLOW UNDULATING SURFACES OF SUPERSTRUCTURES INCLUDING BUT NOT LIMITED TO FLUTES METAL DECKING. JOINT GWB TO SUPERSTRUCTURE WITH A CONTINUOUS BEAD OF ACOUSTICAL SEALANT.
4. BUILDING CODE REQUIRES THAT "SMOKE PARTITIONS" BE SEALED TO STRUCTURE AS INDICATED TO SUCCESSFULLY "….LIMIT THE PASSAGE OF SMOKE….".
FILL FLUTE VOID W/
SAB
GWB SOUND AND
SMOKE CLOSURE
STRIP SECURE TO
STRUCTURE AND SEAL
WITH ACOUSTICAL
SEALANT
1" 1" 2"x20 GA
STRAPS @ 16"
O.C.
ACOUSTICAL SEALANT
(BOTH SIDES)
SLOTTED TOP
TRACK
STUD
SAB
GWB
STEEL BEAM
20 GA Z-BARS
TO
ACCOMMODATE
SFRM
ACOUSTICAL
SEALANT (BOTH
SIDES)
5/ 8"
5/ 8"
5/ 8" 5/ 8"
FLOOR AND ROOF STRUCTURES VARY BY BUILDING.
CONTRACTOR TO VERIFY ALL FLOOR AND ROOF STRUCTURES.
SCALE: 3"=1'-0"
HEAD-OF-WALL CONDITIONS - STUD WALLS - 1 HR FIRE RATED WALLSF1
UL W-L-7042
UL W-L-7143
1 1
DOOR SCHEDULE (SEE ARCH SHEETS FOR LOCATIONS)
BLDG - DOOR # ROOM NAME
A
T" X W" X H"ELEV
DOOR
GR.
HDWR
2" X 3' X 7'
RTG.
FIREGLASS
43H-G50 EX FINISH HEIGHTWESTWESTEASTEAST
WALLS
SOUTHSOUTHFLOOR NORTHNORTH
ROOM FINISH SCHEDULE (SEE ARCH SHEETS FOR LOCATIONS)
LEGEND:
S -SEALED CONCRETE
VT -STATIC DISSIPATIVE VINYL TILE
4V -4" VINYL BASE
PP -PAINTED PLYWOOD
P -PAINTED GYPSUM BOARD
VT OPEN V
BASE
4V
CEILING
P/PP
MAT ELEV
FRAME
MAT HEAD JAMB THLD
DOOR / FRAME TYPES
DOOR AND WINDOW GENERAL NOTES LEGEND
1. CENTER DOOR PULL HARDWARE AT 36" A.F.F., ALL DOORS
TYPICAL.
2. ALL HARDWARE FASTENERS & SCREWS TO MATCH FINISH
OF HARDWARE ITEM. TYPICAL ALL ITEMS.
3. CONTRACTOR TO FIELD MEASURE ALL OPENINGS PRIOR TO
FABRICATION.
DOOR HARDWARE GROUPS
SEE SPECIFICATIONS SECTION 08 71 00 FOR DOOR HARDWARE
GROUPS AND REQUIREMENTS
AL - ALUMINUM
HM - HOLLOW METAL
ELEV - ELEVATION
THLD - THRESHOLD
HDWR - HARDWARE
RTG - RATING
TR ROOM
B
WELDED STEEL HM FRAME
HOLLOW METAL DOORS
-FLUSH
GALVANIZED
2" THICK INSULATED
SIZE
P/PP P/PP P/PPTR ROOM
TR ROOM
2" X 3' X 8' HW-SH-3D81H-133-B A WD A HM 45M
F1 F3 -
NOTES
CAN'T BE ENLARGED TO 8' DUE TO CMU WALLEX EX EX -- EX EX
2" X 3' X 8'152-101 A WD A HM 45M- F1 F3 -
TR ROOM 2" X 3' X 8'237-D131 A WD A HM 45M- F1 F3 -- -
TR ROOM 2" X 3' X 8'237-M119 A WD A HM 45M- F1 F3 -- -- -
TR ROOM 2" X 3' X 8'1007-1125 A WD A HM 45M- F1 F3 -
TR ROOM 2" X 3' X 8'1007-2163 A WD A HM 45M- F1 F3 -
2" X 3' X 7' CAN'T BE ENLARGED TO 8' DUE TO LOW CORRIDOR CEILING1017-2123 TR ROOM A WD A HM 45M- F1 F3 -
REPLACE DOOR & FRAME TO REVERSE SWING
2" X 3' X 7'1017-3036 EXTR ROOM - - CAN'T BE ENLARGED TO 8' DUE TO LOW CORRIDOR CEILINGEX EX EX -- EX EX
TR ROOM 2" X 3' X 8'1523-1030 A WD A HM 45M- F1 F3 -
2" X 3' X 7'1523-1064 EXTR ROOM - - CAN'T BE ENLARGED TO 8' DUE TO CMU WALLEX EX EX -- EX EX
BLDG - ROOM # ROOM NAME
43H-G20 TR ROOM
TR ROOM
TR ROOM
81H-133-B 152-101
TR ROOM237-D131
TR ROOM237-M119
TR ROOM1007-1125
TR ROOM1007-2163
1017-2123 TR ROOM
1017-3036 TR ROOM
TR ROOM1523-1030
1523-1064 TR ROOM
VT OPEN V4V P/PP P/PP P/PP P/PP
VT OPEN V4V P/PP P/PP P/PP P/PP
VT OPEN V4V P/PP P/PP P/PP P/PP
VT OPEN V4V P/PP P/PP P/PP P/PP
VT OPEN V4V P/PP P/PP P/PP P/PP
VT OPEN V4V P/PP P/PP P/PP P/PP
VT OPEN V4V P/PP P/PP P/PP P/PP
VT OPEN V4V P/PP P/PP P/PP P/PP
VT OPEN V4V P/PP P/PP P/PP P/PP
VT OPEN V4V P/PP P/PP P/PP P/PP
CONTRACTOR TO PREP WOOD DOOR AND FRAME FOR:
1. SARGENT 8200 ELECTROMECHANICAL MORTISE LOCK SET 71
ELECTRICAL (FAIL SAFE).
2. PROVIDE 34" ACCESS WITHIN DOOR FROM LOCKSET TO HINGE SIDE
OF DOOR
3. MC-7 HIGH SECURITY MAGNETIC DOOR SECURITY SWITCH.
4. COORDINATE EXACT LOCKSET AND SWITCH WITH THE PHYSICAL
SECURITY CONTRACTOR HIRED BY THE VA.
5. CONTRACTOR IS TO PROVIDE TEMPORARY MORTISE LOCK DURING
CONSTRUCTION OR COORDINATE INSTALLATION OF ACTUAL
LOCKSETS WITH THE VA.
HW-SH-3D
HW-SH-3D
HW-SH-3D
HW-SH-3D
HW-SH-3D
HW-SH-3D
HW-SH-3D
16 GA JAMB STUD
EXTEND WEB OF BOX STUDS
OVER JAMB STUD & ATTACH
w/ (3) #10 SMS @ 6" HEADERS
AND (2) #10 SMS @ 4" HEADERS
ATTACH TRACK TO HEADER w/
#10 SMS @ 12" OC, ALTERNATE
SIDES
DBL STUD BOX HEADER:
4"x20 GA @ OPNGS TO 6'-4" WIDE 6"x20 GA @ OPNGS TO 8'-4" WIDE
6"X16 GA @ OPNGS TO 12'-0" WIDE
EXTEND WEB & ATTACH TO JAMB
STUD BEYOND
SEE ELEVATION BELOW FOR
HEADER ATTACHMENT TO JAMB
STUD
ATTACH RUNNER TRACK TO STUD
BOXED HDR w/ #10 SMS @ 12" OC
TYP EACH FLANGE
TRACK
TRACK
OPENINGS FROM 3'-5" TO 12'-0" WIDE
ELEVATION
DBL STUD
NEW OR EXISTING WALL.
WALL TYPES VARY
CONT WALL CHANNEL WITH #6
SCREW SECURED TO EACH STUD
HEAVY-DUTY GWB MAIN RUNNER @
4'-0" O.C. AND HEAVY-DUTY GYP BD
CROSS 'T' @ 2'-0" O.C. - FASTEN TO
WALL CHANNEL WITH
" POP RIVETS
DRYWALL ATTACHMENT CLIP PER
MFR
" GYP BD
4 LENGTH OF
RUNNER (8" MAX)
SUSPENSION WIRE
SEE RCP FOR
CEILING HEIGHT
DOUBLE STUDS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
C O
L
O
R
A
D
O
L
I
C
E
N
S
E
D
A
R
C
H
I T
E
C
T
S E A
N
M
F
IT
Z
P
A
T
R
I C K
3/8/23
A-601
DOOR SCHEDULE, DETAILS AND
FINISH SCHEDULE
SFTM
ALL
SCALE: 3"=1'-0"
JAMB DETAIL
F1
SCALE: 3"=1'-0"
HEAD DETAIL
F2
SCALE: 3"=1'-0"
DOOR FRAMING DETAIL
F4
HM FRAME
GENERAL FINISH NOTES:
1. REFER TO SPECIFICATIONS FOR ADDITIONAL MATERIAL AND
INSTALLATION REQUIREMENTS.
2. REFER TO SHEET FINISH LEGEND AND ROOM FINISH
SCHEDULE.
3. REFER TO ARCHITECTURAL PLANS TO REFERENCE WALL TYPES.
4. PROVIDE MATERIALS FROM SAME PRODUCTION RUN FOR CONSISTENCY
TRANSITION NOTES:
1. INSTALL TRANSITIONS AT ALL DISSIMILAR FLOOR MATERIALS.
2. FOR ALL FLOOR FINISH AND PATTERN TRANSITIONS THAT OCCUR AT
DOORWAYS, TRANSITION MATERIALS AT CENTERLINE OF DOOR
WHEN DOOR PANEL IS IN THE CLOSED POSITION.
PAINTING NOTES:
1. ALL ADHESIVES AND PAINT TO BE LOW VOC/ODOR.
2. UNLESS OTHERWISE INDICATED, DO NOT PAINT FACTORY-
FINISHED ITEMS OR INSTALLER FINISHED ITEMS.
3. COORDINATE APPLICATIONS OF PAINTS AND ADHESIVES WITH COR.
4. PROVIDE SEALED ENVIRONMENT DURING HVAC FLUSH OUT PERIOD TO
ENSURE ODORS DO NOT TRANSMIT TO ADJACENT SPACES.
CODE NOTES:
1. ALL INTERIOR FINISHES SHALL HAVE FLAME SPREAD IN COMPLIANCE
WITH IBC 2009 TABLE 803.9
INSTALLATION NOTES:
1. ALL FLOOR TILE TO BE CENTERED IN ROOM UNO.
1/2" 9" 1/2"
RED SYMBOL AND
BLACK TEXT
9"X9" MAGNETICALLY
REMOVABLE SIGN
(ONE-PIECE)
5-3/16" X 9" CLEAR
ACETATE INSERT W/
COPY
QUARTER-ROUND
SILVER FRAME
PARTITION AS SCHEDULED
C CENTER LINE OF DOOR
TELECOM ROOM SIDE
L
CORRIDOR SIDE
ADJACENT SPACE
TELECOM
ROOM SIDE
INSTALL 3/4" PLYWOOD TO
8'AFF, MOUNT BOTTOM OF
PLYWOOD 12" AFF PROVIDE
3 ROWS OF HORIZ BACKING
TO SCREW PLYWOOD TO.
DOOR FRAME BEYOND CENTER LINE OF
FLOOR FINISH
CHANGE OR SEAM
TRANSITION STRIP
(TR-1) OR EQUAL,
REFER TO SCHEDULE
FOR INFORMATION
DOOR AS SCHEDULED
EXISTING FLOORING
NEW FLOORING
TOP OF SLAB
TOP OF SLAB
RESILIENT BASE AS
SCHEDULED, EACH
SIDE OF NEW WALL
EXISTING FLOORING
TO REMAIN, EXISTING
ROOM SIDE
NEW FLOORING
SCALE: 6"=1'-0"
TRANSITION TO EXISTING FLOORING
C9
SCALE: 6"=1'-0"
RESILIENT BASE DETAIL
E9
SCALE: NTS
EXAMPLE OF EXISTING SIGNAGE
D6
SCALE: 3"=1'-0"
DO NOT ENTER SIGN DETAIL
E6
GENERAL INTERIOR NOTES
BUILDINGS
81H
BUILDINGS
43H
BUILDINGS
A-301
F1
AT FIRE RATED
PARTITIONS
STRUCTURAL DECK VARIES BY BUILDING.
CONTRACTOR TO VERIFY ALL FLOOR AND ROOF
ASSEMBLIES
SOUND ATTENUATION
BATTS (SAB) PER
SCHEDULE.
CEILING LINE
5/8" GWB BOTH SIDES
A/C GRADE, 3/4" FIRE-
TREATED PLYWOOD TO 8'-0"
ABOVE FINISHED FLOOR
METAL STUDS, SIZE
PER SCHEDULE
BOTTOM OF PLYWOOD TO
BE AT 12" AFF
ACOUSTICAL OR RATED
SEALANT BOTH SIDES
FLOOR LINE
PROVIDE 3 ROWS OF HORIZ BACKING
TO SCREW PLYWOOD TO.
SCALE: 1 1/2"=1'-0"
TYP NEW WALL TYPE
E1
REPLACE SLIDE IN
ROOM NAME TO MATCH
EXISTING - TYPICAL ALL
ROOMS
REPLACE SLIDE IN
ROOM NAME TO MATCH
EXISTING - TYPICAL ALL
ROOMS
REPLACE SLIDE IN
ROOM NAME TO MATCH
EXISTING - TYPICAL ALL
ROOMS
CONTRACTOR TO
PROVIDE 1 NEW SIGN
FOR B81-H, TR 133-B
SCALE: 3"=1'-0"
GYPSUM BOARD CEILING
E3
UNDERSIDE OF STRUCTURE
OR INTERSTITIAL FLOOR MTL RUNNER, TYP
MTL STUD,
TYP
METAL
STUD
HEADER,
TYP.
HEIGHT SHALL
VARY
HM DOOR
FRAME, TYP
JAMB
ANCHOR
TYP
EXIST GWB &
MTL STUD
WALL TO
REMAIN
EXIST GWB &
MTL STUD
WALL TO
REMAIN
0' - 4" TYP
DOOR WIDTH AS
SCHEDULED
0' - 4" TYP
SCALE: 3/4"=1'-0"
DOOR FRAMING ELEVATION
F5
UL: U465 1
TO BE USED IN REPAIR AREAS WHERE
NEW WALLS ARE BUILT OR MOVED
AutoCAD SHX Text 00404366
SPD
TR 31
TR 31:2
TR 31:3
TR 31:7, 9,11
TR 31:2
TR 31:3
TR 31:2
TR 31:3TR 31:2
TR 31:3
TR 31:10, 12,14
TR 31:13, 15,17
TR 31:19, 21,23
TR 31:5
3RD FLOOR TR
OUTDOOR UNIT
2 ND FLOO R TR
OUTDOOR UNIT
1017.EP103
SSSF
3/4 INCH = 1 FOOT
4'4" 8" 1' 2'
NORTH
KEY PLAN
ELECTRICAL ENLARGED PLAN-
THIRD LEVEL POWER PLAN
F1 3TH FLOOR-ROOM 3035-NEW WORK
GENERAL NOTES
KEYED NOTES
TYP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
03/08/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
CD (100%) SUBMITTAL
VCI Project Management Construction Management Engineering
F4 ROOF LEVEL-NEW WORK
1. NEW 5KW RACK-MOUNTED 208 V UNINTERRUPTIBLE POWER SUPPLY (UPS) WITH
NEMA L21-20P INPUT AND L21-20R OUTPUT.
2. PROVIDE NEW BRANCH 20A 120/208 CIRCUIT FOR EACH RACK. PROVIDE NEW
CONDUIT, CONDUCTORS AND DEVICES TO SUPPLY EACH NEW L21-20R
RECEPTACLE. PROVIDE 3/4"C - 4#10 1#10 GND.
3. NEW POWER RECEPTACLE, SEE PANEL SCHEDULE ON SHEET E-701 FOR
ADDITIONAL INFORMATION.
4. PROVIDE SPD DEVICE IN SURFACE MOUNTED ENCLOSURE BELOW NEW
PANEL.SEE PANEL SCHEDULE ON SHEET E-701 FOR ADDITIONAL INFORMATION.
5. PROVIDE TWO (2) 208V 20A VERTICAL RACK POWER DISTRIBUTION UNITS.
6. PROVIDE 30A/2P NON-FUSED DISCONNECT.
7. PROVIDE 2 #8 + #10GND 3/4" IMC.
8. CONDENSATION PUMP. COORDINATE ELEVATION OF POWER OUTLET WITH MOUNTING
HEIGHT OF CONDENSATE PUMP.
9. PROVIDE LIGHTNING PROTECTION FOR THE OUTDOOR UNIT AND CONNECT TO THE
EXISTING CIRCUIT PER NFPA 780. SEE LIGHTNING PROTECTION SPECS.
FULLY SPRINKLERED
CU-02
CU-02
1. REFER TO EG001 FOR LEGENDS AND ABBREVIATIONS.
2. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING
WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL
PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN
REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
3. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION
WHERE FEASIBLE. CONSTRUCTION AREA CONDITIONS MAY DIFFER FROM
THOSE INDICATED.
4. MINIMUM BRANCH CIRCUIT SIZE SHALL BE 2#12, 1#12G., 3/4"C.
5. CONTRACTOR SHALL COORDINATE FINAL POINT OF CONNECTIONS
WITH VA COR PRIOR TO ROUGH-IN.
6. COORDINATE FINAL EQUIPMENT CONNECTIONS AT EQUIPMENT WITH
EQUIPMENT SUPPLIER, PRIOR TO ROUGH-IN.
7. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL LISTING
PANEL AND CIRCUIT FEEDING THE WIRING DEVICE.
8. UPDATE PANEL SCHEDULES AFFECTED BY RENOVATION.
9. NEW CIRCUIT BREAKERS PROVIDED SHALL MATCH THE EXISTING TYPE
OF CIRCUIT BREAKERS IN PANEL BEING RENOVATED.
10. CONTRACTOR SHALL COMPLY WITH LATEST VERSION OF NEC.
11. LOCATE DISCONNECT SWITCHES TO MAINTAIN WORKING
CLEARANCES PER NEC 110.26.
12. FOR EXISTING EQUIPMENT, SUCH AS WIRING DEVICES, CONDUITS, ETC.,
SHOWN ON PLANS TO BE REMOVED, COMPLETELY CUT/CAP CONDUITS AT
THE AREA OF WORK PERIMETER AND REMOVE CONDUIT WITHIN THE WORK AREA,
DISCONNECT WIRING AT THE OVERCURRENT PROTECTIVE DEVICE AND REMOVE
WIRING COMPLETELY FROM THE ABANDONED CONDUITS BACK TO JUNCTION
BOX OR PANEL
13. DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE OVERCURRENT
PROTECTIVE DEVICE. COMPLETELY REMOVE ALL ABANDONED WIRING.
14. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS
PASSING THROUGH RENOVATED AREAS AND SERVICING UNDISTURBED AREAS.
15. PROVIDE GROUNDING PER NEC ARTICLE 250.
3/8/2023
RD
ADDENDUM
07/14/2023
T
EXISTING AHU
EXISTING EF
1017.M-103
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
FULLY SPRINKLERED
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .