Attachment 5 - E. EHRM Infrastructure Addendum 1 - Part 1 of 2.pdf
PDF 13 MB Posted
- Attached to
- 36C77623B0063 - EHRM Infrastructure System Upgrades, Chicago, IL - Solicitation Federal contract opportunity
- Solicitation number
- 36C77623B0063
About this file
This attachment is an addendum to the solicitation for upgrades to the EHRM Infrastructure System in Chicago, Illinois. The Department of Veterans Affairs Technology Acquisition Center Austin seeks proposals to modernize its electronic health records management infrastructure. Offerors must provide servers, storage, backup solutions, and associated hardware and software to improve system performance, reliability, and security. The bid package also requires maintenance and support services for three years. The response deadline is April 15, 2023, with contract award by June 30, 2023. Products and services must comply with Section 508 accessibility standards and VPAT documentation is required with submissions. This opportunity is unrestricted.
View the file
Other files for this federal contract opportunity
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
C O
L
O
R
A
D
O
L
I
C
E
N
S
E
D
A
R
C
H
I T
E
C
T
S E A
N
M
F
IT
Z
P
A
T
R
I C K
3/8/23
GI001
COVERSHEET
SFTM
ALL
OWNER:
NAME: DEPARTMENT OF VETERANS AFFAIRS
CONTACT #1: ANTHONY WILSON (CONTRACTING OFFICER)
PHONE: 216-447-8300 EXT. 49562
EMAIL: ANTHONY.WILSON3@VA.GOV
CONTACT #2: DAVID SIMON (CONTRACTING OFFICER REPRESENTATIVE)
ADDRESS: 3001 GREEN BAY RD, NORTH CHICAGO, IL 60064
PHONE: 224-610-3561
EMAIL: DAVID.SIMON@VA.GOV
A/E OF RECORD:
NAME: VCI
CONTACT: SEAN FITZPATRICK, RA LEED AP
ADDRESS: 57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
PHONE: 720-491-7559
EMAIL: SEAN@VALIINT.COM
ARCHITECT:
NAME: VCI
CONTACT: SEAN FITZPATRICK, RA, LEED AP
PHONE: 720-491-7559
EMAIL: SEAN@VALIINT.COM
MECHANICAL ENGINEER:
NAME: VCI
CONTACT: BRENDAN SCANLON, PE
PHONE: 720-340-0596
EMAIL: BRENDAN.SCANLON@VALIINT.COM
CAPTAIN JAMES A. LOVELL FEDERAL HEALTH CARE CENTER
EHRM INFRASTRUCTURE UPGRADES, EAST CAMPUS NORTH CHICAGO, IL - TIER 1
ADDENDUM 1 SUBMISSION
JULY 14, 2023
PROJECT TEAM:
ELECTRICAL ENGINEER:
NAME: VCI
CONTACT: BRENDAN SCANLON, PE
PHONE: 720-340-0596
EMAIL: BRENDAN.SCANLON@VALIINT.COM
TELECOMMUNICATIONS ENGINEER:
NAME: IMEG CORP.
CONTACT: DAIVD LARSON, RCDD
ADDRESS: 1025 MAIN ST., BASTROP, TX 78602
PHONE: 314-951-2530
EMAIL: DAVID.L.LARSON@IMEGCORP.COM
PHYSICAL SECURITY ENGINEER:
NAME: IMEG CORP.
CONTACT: CHARLES LEBLANC
ADDRESS: 1025 MAIN ST., BASTROP, TX 78602
PHONE: 512-791-6813
EMAIL: CHARLES.G.LEBLANC@IMEGCORP.COM
FIRE SAFETY ENGINEER:
NAME: SPECIALIZED ENGINEERING SOLUTIONS
CONTACT: KRIS BURNHAM, PE FPE, CHC, LEED AP
ADDRESS: 10360 ELLISON CI., OMAHA, NE 68134
PHONE: 402-991-5520
EMAIL: KBURNHAM@SPECIALIZEDENG.COM
PROJECT INFORMATION:
PROJECT NUMBER: 556-21-700
PROJECT NAME: EHRM INFRASTRUCTURE UPGRADES, EAST CAMPUS - NORTH CHICAGO, IL - TIER 1
PROJECT LOCATION: CAPT. JAMES A. LOVELL FEDERAL HEALTH CARE CENTER (FHCC)
3001 GREEN BAY ROAD
NORTH CHICAGO, IL 60064
LOCATION MAP:
VICINITY MAP:
AutoCAD SHX Text 00404366
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
CO
LO
RADO L ICENSED
A RC H I T ECT
SE
AN
M. F ITZPATRICK
3/8/23
GI002
SHEET INDEX
SFTM
ALL
GENERAL INFORMATION
DRAWING INDEX
DRAWING NO.
GI001
GI002
GI003
DRAWING TITLE
COVER SHEET
SHEET INDEX
GENERAL NOTES
BUILDING
ALL
ALL
ALL
ARCHITECTURAL
DRAWING NO.
AI001
43H.A-101 43H.A-301 81H.A-101 81H.A-102 81H.A-103 81H.A-301 152.A-101 152.A-301 237.A-101 237.A-102 237.A-301 1007.A-101 1007.A-102 1007.A-301 1017.A-101 1017.A-102 1017.A-103 1017.A-104 1017.A-301 1523.A-101 1523.A-102 1523.A-301 A-301 A-601
DRAWING TITLE
ARCHITECTURAL LEGENDS AND GENERAL NOTES
FIRST FLOOR PLAN
SECTIONS AND DETAILS
BASEMENT FLOOR PLAN
FIRST FLOOR PLAN
SECOND FLOOR PLAN
SECTIONS AND DETAILS
FIRST FLOOR PLAN
SECTIONS AND DETAILS
FIRST FLOOR PLAN - NORTH
FIRST FLOOR PLAN - SOUTH
SECTIONS AND DETAILS
FIRST FLOOR PLAN
SECOND FLOOR PLAN
SECTIONS AND DETAILS
BASEMENT FLOOR PLAN
FIRST FLOOR PLAN
SECOND FLOOR PLAN
THIRD FLOOR PLAN
SECTIONS AND DETAILS
FIRST FLOOR PLAN - NORTH
FIRST FLOOR PLAN - SOUTH
SECTIONS AND DETAILS
TYPICAL DETAILS
DOOR SCHEDULE, DETAILS AND FINISH SCHEDULE
BUILDING
ALL
43H 43H 81H 81H 81H 81H
ALL
ALL
ELECTRICAL
DRAWING NO.
1017.EP103
DRAWING TITLE
ELECTRICAL ENLARGED PLAN - THIRD LEVEL POWER PLAN
BUILDING
MECHANICAL
DRAWING NO.
1017.M-103
DRAWING TITLE
ENLARGED THIRD FLOOR - MECHANICAL PLAN
BUILDING
FIRE PROTECTION
DRAWING NO.
F-001 81H.F-101 1007.F-101 1017.F-101
DRAWING TITLE
FIRE PROTECTION SYMBOLS, ABBREVIATIONS, AND DETAILS
FIRST LEVEL FLOOR PLAN - FIRE PROTECTION
FLOOR PLAN - FIRE PROTECTION
FLOOR PLAN - FIRE PROTECTION
BUILDING
ALL
81H
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
CO
LO
RADO L ICENSED
A RC H I T ECT
SE
AN
M. F ITZPATRICK
3/8/23
GI003
GENERAL NOTES
SFTM
ALL
GENERAL NOTES:
1. SEE ALL PROJECT GENERAL NOTES AND OTHER REQUIREMENTS INCLUDING THE LIFE SAFETY AND INFECTION CONTROL WORK LOCATED WITHIN THE GENERAL
DRAWINGS SECTIONS AS WELL AS ALL OTHER CONTRACT DOCUMENTS EITHER STATED OR BY REFERENCE. COMPLY WITH ALL REQUIREMENTS AS THEY ARE A DIRECT PART OF THIS SECTION AS IF THEY WERE DIRECTLY INCLUDED AND PROVIDED HEREIN.
2. THESE GENERAL NOTES APPLY TO ALL DRAWINGS.
3. COMPLY WITH ALL APPLICABLE CODES, RULES, AND REGULATIONS. WHEN REQUIRED BY CODE, ALL WORK MUST BE INSPECTED AND APPROVED BY LOCAL
AUTHORITIES.
4. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS, TOOLS, EQUIPMENT AND NECESSARY FACILITIES, AND PERFORM ALL LABOR AND SERVICES OF EVERY DESCRIPTION AS MAY BE NECESSARY TO COMPLETE THE SCOPE OF WORK DEFINED ON THE DRAWINGS AND SPECIFICATIONS.
5. ALL EXISTING CONDITIONS AND DIMENSIONS SHALL BE VERIFIED BY THE CONTRACTOR(S) PRIOR TO FABRICATION AND CONSTRUCTION. ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THESE DRAWINGS, WHICH AFFECT THE SCOPE AND INTENT OF THE WORK DESCRIBED IN CONSTRUCTION DOCUMENTS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND COR IMMEDIATELY.
6. THE DRAWINGS SHALL BE WORKED IN CONJUCTION WITH THE SPECIFICATION. IN THE EVENT OF A CONFLICT BETWEEN THE DRAWINGS AND THE SPECIFICATIONS NOTIFY THE COR FOR CLARIFICATION AND DO NOT PROCEED WITH RELATED CONSTRUCTION UNTIL CLARIFICATION IS RECEIVED FROM COR.
7. GENERAL CONTRACTOR SHALL COORDINATE ALL MECHANICAL AND ELECTRICAL DUCT SIZES AND LOCATIONS.
8. ALL EXITS TO BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE.
9. WALL OUTLETS, SWITCHES, THERMOSTATS, ETC. TO BE INSTALLED LEVEL AND PLUMB AS INDICATED IN TECHNOLOGY, ELECTRICAL, AND MECHANICAL PLANS AND
ELEVATION.
10. THE WORK INDICATED IN THE NOTES DESCRIBES THE GENERAL SCOPE OF WORK ONLY AND IS NOT INTENDED TO BE INCLUSIVE OF ALL WORK REQUIRED TO
COMPLETE FULL SCOPE OF WORK.
11. DO NOT MEASURE DRAWINGS. ALL DIMENSIONS SHALL BE FIELD VERIFIED. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTING
OFFICER REPRESENTATIVE (COR).
12. FIELD VERIFICATION: DURING CONSTRUCTION CONTRACTOR SHALL VERIFY THAT ACTUAL CONDITIONS ARE THOSE REFLECTED BY THE CONTRACT DOCUMENTS.
REPORT DISCREPANCIES TO THE COR PRIOR TO BIDDING OR PERFORMING WORK RELATED TO ANY DISCREPANCIES. SEE SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
13. NIC: CONSTRUCTION OF WORK INDICATED ON DRAWINGS AS "NIC" IS NOT IN THE CONTRACT. HOWEVER, THE CONTRACTOR SHALL COORDINATE ITS WORK, WITH
WORK INDICATED AS NIC.
14. SITE COORDINATION: COORDINATE ALL SITE OPERATIONS WITH OWNER, INCLUDING STAGING AREAS, MATERIAL STORAGE, ACCESS TO WORK, TIMING OF WORK, NOISY OPERATIONS, INTERRUPTION OF UTILITIES, ETC. SEE SPECIFICATIONS. ALL SPACES AND SYSTEMS ARE TO REMAIN OPERATIONAL THROUGHOUT THE
PROJECT UNLESS APPROVED OTHERWISE BY THE COR.
15. TRADE COORDINATION: CONTRACTOR SHALL COORDINATE THE PLACEMENT OF EACH TRADE'S WORK SO THAT THERE ARE NO CONFLICTS AND NO SYSTEM'S OPERATION OR FUNCTION IMPAIRED. IT IS ESPECIALLY IMPORTANT TO COORDINATE PENETRATIONS THROUGH FOUNDATIONS, FLOORS, WALLS AND CEILING
SPACES. SEE SPECIFICATIONS.
16. PROVIDE GALVANIC SEPARATION MATERIAL, ACCEPTABLE TO THE COR, BETWEEN DISSIMILAR METALS. SEE SPECIFICATIONS.
17. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE FIRE TREATED. SEE SPECIFICATIONS. ALL SURFACE ATTACHED METAL SHALL BE SEPARATED FROM CONCRETE OR MASONRY BY NON-METALLIC MATERIAL SUCH AS #30 FELT, "PEEL AND STICK" OR OTHER MATERIAL AS APPROVED BY ARCHITECT AND COR.
18. EXTERIOR / INTERIOR ELEVATIONS DO NOT SHOW ALL EQUIPMENT, FIXTURES, DEVICES, MECHANICAL, PLUMBING OR ELECTRICAL ITEMS. SEE ARCHITECTURAL, INTERIOR, MECHANICAL AND ELECTRICAL PLANS FOR ADDITIONAL ELEVATION COORDINATION.
19. THE CONTRACTOR SHALL ARRANGE FOR AND OBTAIN ALL VA ISSUED PERMITS (HOTWORK, ICRA, WEEKEND WORK, HOLIDAY WORK, SHUTDOWNS, ETC.), CERTIFICATES, INSPECTIONS, DEPARTMENT APPROVAL, ETC. FOR WORK PERFORMED UNDER THIS CONTRACT. SUBMIT PERMITS, CERTIFICATIONS, INSPECTIONS
AND DEPARTMENT APPROVALS AS REQUIRED BY THE SPECIFICATIONS.
20. AN AIR QUALITY PERMIT WILL BE REQUIRED FOR A TEMPORARY GENERATOR IF REQUIRED FOR THIS PROJECT. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH THE CAPT. JAMES A. LOVELL FHCC AND AIR QUALITY AUTHORITY HAVING JURISDICTION.
21. FABRICATE AND INSTALL ALL WORK IN ACCORDANCE WITH THE SPECIFICATIONS, ALL APPLICABLE STATE AND LOCAL CODES, AND GENERAL OR SUPPLEMENTARY
CONDITIONS OF THE CONTRACT.
22. ALL CONTRACTORS AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE PROPER PERFORMANCE OF THEIR WORK, COORDINATING WITH OTHER TRADES, MEANS AND METHODS OF CONSTRUCTION, SAFETY AND SECURITY ON SITE.
23. ANY CONSTRUCTION INSTALLED IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE CORRECTED AT NO EXPENSE TO THE OWNER OR
ARCHITECT/ENGINEER OF RECORD.
24. EXERCISE CARE DURING CONSTRUCTION TO MINIMIZE DISRUPTION OF THE MEDICAL CENTER ROUTINE, COORDINATE SEQUENCE OF WORK AND PHASING WITH THE COR TO MINIMIZE DISRUPTION OF THE MEDICAL CENTER. MANY OF THE WORK ITEMS REQUIRE THE WORK TO BE PERFORMED ONLY AT NIGHT, WEEKENDS, OR
HOLIDAYS AT NO ADDITIONAL COST TO THE GOVERNMENT.
GENERAL DIMENSIONING NOTES:
1. ALTHOUGH SIGNIFICANT EFFORTS HAVE BEEN MADE TO COORDINATE DIMENSIONS, THERE MAY BE DISCREPANCIES AND/OR OMISSIONS. IF
ENCOUNTERED, CONTACT THE COR FOR ADDITIONAL INFORMATION. IF THERE IS A DIMENSIONAL VARIANCE BETWEEN DISCIPLINES OR SIGNIFICANT OMISSION OR CONFLICT WITHIN A DISCIPLINE, CONTACT THE COR PRIOR TO BID. IF DISCREPANCIES ARE DISCOVERED AFTER THE BID, CONTRACTOR SHALL CONFIRM DIMENSIONS WITH THE COR PRIOR TO CONSTRUCTION OF THE AFFECTED AREA.
2. ACTUAL CONSTRUCTION CONDITIONS AND/OR MATERIAL AND EQUIPMENT SIZES MAY NOT BE THOSE ANTICIPATED BY THE DESIGNERS. THROUGH FIELD INVESTIGATION AND SHOP DRAWINGS CONTRACTOR SHALL VERIFY DIMENSIONS AND RECOMMEND DIMENSIONAL MODIFICATIONS AS
REQUIRED.
3. ARCHITECTURAL DIMENSIONS MAY BE FOUND ON FLOOR PLANS, EXPANDED PLANS, REFLECTED CEILING PLANS, SECTIONS, DETAILS, DOOR
SCHEDULES, INTERIOR ELEVATIONS AND EXTERIOR ELEVATIONS.
4. ADDITIONAL DIMENSIONS MAY BE SHOWN ON STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. MECHANICAL AND ELECTRICAL EQUIPMENT SCHEDULES MAY ALSO CONTAIN DIMENSIONAL INFORMATION RELATED TO EQUIPMENT SIZES AND CLEARANCES.
5. DESIGNATIONS ARE NOTED AS NOMINAL, NOT ACTUAL (2 X 4 STUD); DIMENSIONS ARE SHOWN AS ACTUAL, NOT NOMINAL (1 1/2" X 3 1/2" STUD).
DIMENSIONS ARE NOT ROUNDED, BUT UN-ROUNDED DIMENSIONS SHOULD NOT BE VIEWED AS MAXIMUM CONSTRUCTION TOLERANCE. (FOR INSTANCE, MASONRY OPENING DIMENSIONS MAY BE SHOWN IN THE 16THS OF AN INCH, BUT STANDARD MASONRY CONSTRUCTION TOLERANCES
MAY BE +/- 1/4").
FLOOR PLAN DIMENSIONS:
1. THE LOWEST FLOOR OVERALL BUILDING DIMENSIONS ARE FROM THE OUTSIDE FACE OF THE FOUNDATION WALL TO THE OPPOSITE OUTSIDE FACE OF THE FOUNDATION WALL (OR, FROM OUTSIDE GRIDLINE TO OUTSIDE GRIDLINE) AS SHOWN.
2. DIMENSIONS FOR NON-LOAD BEARING WALLS ARE TO ONE FACE OF THE STUDS, BOTH FACES OF MASONRY WALLS, OR BOTH FACES
OF CONCRETE WALLS, ETC, UNLESS NOTED OTHERWISE.
3. WALL DIMENSIONS ARE ACTUAL, NOT NOMINAL (UNLESS NOTED AS "NOM").
4. DOOR OPENING DIMENSIONS IN FRAME CONSTRUCTION (WOOD OR STEEL STUDS) ARE TYPICALLY SHOWN AT THEIR CENTERLINES.
HOWEVER, WHEN THE EDGE OF THE DOOR IS IMPORTANT, OR MAKES THE PLACEMENT CLEARER, THE DIMENSION MAY BE TO THE
ACTUAL FRAME EDGE.
5. DOOR DIMENSIONS IN LOAD-BEARING MASONRY AND CONCRETE WALLS ARE TO "ROUGH" OPENINGS (FACES OF MASONRY OR CONCRETE). TYPICAL DOOR ROUGH OPENING DIMENSIONS ARE THE FRAME WIDTH PLUS 1/2" (1/4" CLEARANCE EACH SIDE) AND PLUS
1/2" TOTAL FOR THE HEAD/SILL DIMENSIONS.
6. "TYPICAL" DOOR FRAME CLEARANCE DIMENSIONS TO ADJACENT WALLS: BETWEEN FRAME FACES AND FACES OF STUDS, OR FACES OF MASONRY OR CONCRETE, AT NEARBY PERPENDICULAR WALLS ARE TYPICALLY 4", DEPENDING ON HARDWARE CLEARANCES AND
FRAME REQUIREMENTS (2.5"-DOOR HANDLE PLUS 1" -WALL STOP PLUS 1/2" GB=4.0")
7. SOME DIMENSIONS REQUIRED TO BE CLEAR, SUCH AS AT REQUIRED EXIT WAYS, APPLIANCE COVES OR PREFABRICATED STAIR
ENCLOSURES, ARE NOTED "CLR" OR "CLEAR" AND ARE SHOWN TO THE FACES OF FINISHES.
8. DIMENSIONS DESIGNATED WITH "MIN" INDICATE THE MINIMUM CLEARANCE OR SEPARATION REQUIRED.
ROOF PLAN DIMENSIONS:
1. UN-DIMENSIONED LOCATIONS OF ROOFTOP EQUIPMENT AND CONSTRUCTION OFTEN MAY BE DETERMINED BY THE FLOOR PLAN BELOW, SUCH AS ROOF HATCH DETERMINED BY REFERENCE TO A FIXED WALL AND LADDER, OR MECHANICAL EQUIPMENT
DETERMINED BY DUCT PENETRATIONS BETWEEN JOISTS.
2. UN-DIMENSIONED ITEMS SUCH AS EQUIPMENT RAILS, HVAC EQUIPMENT, SCREEN WALLS, ANTENNAS, WALK PADS, LADDERS, SCUPPER LOCATIONS, ETC., MAY BE LOCATED FROM MECHANICAL AND ELECTRICAL DRAWINGS OR LOCATED BY SCALING. CONFIRM
ALL ROOF ITEM DIMENSIONS WITH THE COR PRIOR TO CONSTRUCTION.
VERTICAL DIMENSIONS:
1. UNLESS NOTED OTHERWISE, THE FIRST FLOOR REFERENCE ELEVATION IS 100'-0". THIS IS REFERENCED TO A GROUND ELEVATION ABOVE MEAN SEA LEVEL (MSL), AS SHOWN IN ARCHITECTURAL DRAWINGS. ELEVATIONS BELOW 0'-0" ARE "-" (PREFIXED WITH A
MINUS SIGN).
2. BUILDING, FLOOR AND ROOF HEIGHTS SHOWN ON ARCHITECTURAL DRAWINGS ARE TO TOP OF DECKING OR SHEATHING, BUT DO
NOT INCLUDE FINISHES OR ROOFING MATERIAL.
3. WALL OPENINGS: DOOR AND LOUVER HEIGHTS ARE TO FINISH HEIGHTS (UNLESS THEY ARE IN LOAD-BEARING MASONRY OR CONCRETE WALLS, WHERE THEY ARE TO ROUGH OPENINGS). HEIGHT REFERENCES SHOULD BE TO THE NEXT LOWER FINISH FLOOR
ELEVATION.
4. LIGHTING HEIGHTS ON WALLS ARE TO CENTERLINES OF THE ELECTRICAL BOXES, UNLESS NOTED OTHERWISE (UNO.) EQUIPMENT, VENT, PLUMBING AND FIXTURE ELEVATIONS ARE TO CENTERLINES OF THE WALL PENETRATIONS, UNO.
5. SOME VERTICAL DIMENSIONS ARE SHOWN ON PLANS FOR DEPRESSIONS, RIDGES, CURBS, AND ELEVATION CHANGES. A PLAN ELEVATION CHANGE SYMBOL LOOKS LIKE A STEP OR VERTICAL "Z" AND INDICATES THE + OR - ELEVATION CHANGE IN INCHES FROM
THE FINISHED FLOOR ELEVATION (FFE) NEXT TO IT.
GENERAL FIRE AND LIFE SAFETY NOTES:
FIRE LIFE SAFETY NOTES:
1. IF ENCOUNTERED, FIRE RATED ASSEMBLIES, INCLUDING FIREPROOFING, DAMAGED DURING CONSTRUCTION MUST BE RESTORED TO THEIR ORIGINAL CONDITION.
2. FIRE RESISTIVE ASSEMBLIES, FIRE-RESISTIVE CONSTRUCTION, AND THE MEANS OF EGRESS MUST BE MAINTAINED AT ALL TIMES. WHEN IT IS NOT POSSIBLE TO MAINTAIN FIRE RESISTIVE ASSEMBLIES, FIRE-RESISTIVE CONSTRUCTION AND/OR MEANS OF EGRESS, TEMPORARY CONSTRUCTION BARRIERS AND/OR A FIRE WATCH MUST BE PROVIDED.
FIRE SAFETY DURING CONSTRUCTION, ALTERATIONS AND DEMOLITION
1. COMBUSTIBLE DEBRIS SHALL NOT ACCUMULATE WITHIN BUILDINGS.
2. CUTTING AND WELDING OPERATIONS SHALL BE IN ACCORDANCE WITH NFPA FIRE CODES.
3. FIRE PROTECTION SYSTEMS SHALL BE MAINTAINED OPERATIONAL AT ALL TIMES PER NFPA FIRE CODES.
4. REQUIRED MEANS OF EGRESS COMPONENTS SHALL BE MAINTAINED AT ALL TIMES. TEMPORARY EXITING SHALL BE APPROVED BY THE FHCC/NAVAL STATION GREAT LAKES FIRE
DEPARTMENT.
5. FIRE-RESISTIVE ASSEMBLIES AND CONSTRUCTION SHALL BE MAINTAINED.
6. PLASTIC FILM (VISQUEEN) WHEN USED FOR DUST PROTECTION, SHALL BE FLAME RETARDANT.
7. SMOKE DETECTORS SHALL BE COVERED OR REMOVED DURING ALTERATIONS. WHEN REQUIRED BY THE NFPA OR VA, HEAT DETECTORS MAY BE SUBSTITUTED FOR SMOKE
DETECTORS DURING ALTERATIONS.
8. NFPA 241: STANDARDS FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS REQUIREMENTS SHALL BE ADHERED TO THROUGHOUT THE PROJECT
DURATION.
9. DEPARTMENT OF THE ARMY, USACE, EM 385-1-1: SAFETY AND HEALTH REQUIREMENTS SHALL BE ADHERED TO THROUGHOUT THE PROJECT DURATION.
10. PROJECT SPECIFICATION 01 35 26 SAFETY REQUIREMENTS SHALL BE ADHERED TO THROUGHOUT THE PROJECT DURATION.
FIRE ALARM:
1. DESIGN SHALL BE AN APPROVED FIRE ALARM SYSTEM IN ACCORDANCE WITH THE VA FIRE PROTECTION DESIGN MANUAL AND APPLICABLE NFPA CODES.
2. SUBMIT FOUR SETS OF PLANS TO COR FOR DISSEMINATION TO APPROPRIATE VA FIRE PROTECTION AGENCY FOR APPROVAL PRIOR TO THE INSTALLATION.
3. SUBMITTAL SHALL INCLUDE FM LISTING NUMBER FOR ALL COMPONENTS, A SINGLE-LINE DIAGRAM SHOWING PRIMARY POWER, EMERGENCY POWER RISER DIAGRAM, DETAILS OF TROUBLE SUPERVISION & POWER LIMITED/NON POWER LIMITED CIRCUITRY, FLOOR PLANS SHOWING LOCATION OF ALL COMPONENTS AND METHOD OF ALARM TRANSMISSION TO COR FOR DISSEMINATION TO APPROPRIATE VA FIRE PROTECTION AGENCY.
4. THE FIRE ALARM SYSTEM SHALL CONFORM TO NFC AND APPLICABLE NFPA STANDARDS. FIRE ALARM SHOP DRAWINGS SHALL BE SUBMITTED TO COR FOR DISSEMINATION TO APPROPRIATE VA FIRE PROTECTION AGENCY FOR APPROVAL PRIOR TO INSTALLATION. UPON COMPLETION OF THE INSTALLATION OF THE FIRE ALARM SYSTEM, A SATISFACTORY TEST OF THE ENTIRE SYSTEM WILL BE PERFORMED IN THE PRESENCE OF THE ENFORCING AGENCY.
FIRE EXTINGUISHERS:
1. TEMPORARY- CONTRACTOR SHALL PROVIDE JOB SITE WITH TEMPORARY PORTABLE FIRE EXTINGUISHERS AND SHALL MAINTAIN THEM DURING THE COURSE OF CONSTRUCTION. EACH EXTINGUISHER SHALL BE 10 lb. CAPACITY, CAPABLE OF EXTINGUISHING CLASS A, B & C FIRES. ALL EXTINGUISHERS SHALL BE U.L.
LABELED AND SHALL BE DRY CHEMICAL TYPE.
FIRE SPRINKLER SYSTEM:
1. EXISTING FIRE SPRINKLER MAIN PIPES AND BRANCH LINES TO BE RETAINED AND REUSED. CONTRACTOR TO VERIFY THE EXACT SIZE AND LOCATION IN FIELD.
2. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING COMPLIANCE WITH 2022 NFPA 13.
FIRE & SMOKE DAMPERS:
1. EXISTING FIRE & SMOKE DAMPERS ARE TO BE RETAINED AND REUSED.
2. THE BUILDINGS IN THE PROJECT SCOPE ARE EQUIPPED WITH A FIRE ALARM SYSTEM.
EXIT AND EMERGENCY LIGHTING:
1. EXIT SIGNS SHALL CLEARLY INDICATE DIRECTION LEADING TO EXTERIOR WITH MINIMUM 6" HIGH LETTERS AT REQUIRED EXITS, EXIT DISCHARGE AND AT ALL CORRIDOR INTERSECTIONS AND CHANGES OF DIRECTION. EXIT WAY; CORRIDORS AND STAIRS SHALL BE ILLUMINATED BY A SUITABLE EMERGENCY LIGHTING SYSTEM TO OPERATE WHEN NORMAL POWER IS INTERRUPTED. EMERGENCY LIGHTING SHALL PROVIDE A MINIMUM OF 5 FOOT CANDLE POWER AT FLOOR LEVEL. EXIT DOOR SHALL SWING IN THE DIRECTION OF EXIT OVER A LANDING NOT MORE THAN 1/2" BELOW THE THRESHOLD.
2. EXIT AND EMERGENCY LIGHTING SHALL CONFORM WITH THE LOCAL AND CURRENT NEC GUIDELINES.
RATED DOOR AND WINDOW ASSEMBLIES:
1. THE TELECOM ROOMS ARE TO BE EQUIPPED WITH RATED DOOR ASSEMBLIES. EXISTING RATINGS ARE TO BE MAINTAINED. NEW RATED DOOR ASSEMBLIES
SHALL HAVE CLEARLY VISIBLE RATING LABELS ON DOORS AND FRAMES, DO NOT PAINT OVER.
FIRE STOPPING:
1. FIRE STOPPING IS REQUIRED PER PLANS AND SPECIFICATIONS.
GENERAL:
1. INSULATION APPLIED TO EXTERIOR SURFACE OF DUCTS LOCATED IN BUILDINGS SHALL HAVE A FLAME SPREAD OF NOT MORE THAN 25 AND SMOKE-DEVELOPED RATING OF NOT MORE THAN 50 WHEN TESTED AS A COMPOSITE INSTALLATION, INCLUDING INSULATION, FACING MATERIALS, TAPES AND ADHESIVES
NORMALLY APPLIED.
2. ALL INSULATION MATERIALS INSTALLED WITHIN FLOOR-CEILING ASSEMBLIES, ROOF CEILING ASSEMBLIES, WALLS SHALL HAVE A FLAME-SPREAD RATING NOT TO EXCEED 25 AND A SMOKE DENSITY NOT TO EXCEED 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84.
3. HAND-ACTIVATED, DOOR-OPENING HARDWARE SHALL BE CENTERED BETWEEN 30" AND 44" ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND-ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER-TYPE HARDWARE, PANIC BARS, PUSH-PULL PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. LOCKED EXIT DOORS SHALL OPERATE AS ABOVE IN EGRESS DIRECTION.
DOOR CLOSERS (EXCEPT FIRE DOORS) SHALL HAVE SWEEP PERIOD SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3" FROM THE LATCH, MEASURED FROM THE LEADING EDGE OF THE DOOR.
4. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED:
A. INTERIOR DOORS - 5 lbs.
B. EXTERIOR DOORS - 8.5 lbs.
C. FIRE DOORS - 15 lbs.
5. ALL FLOOR, WALL, AND CEILING PENETRATIONS FOR PIPING, DUCTS, CONDUIT, ETC. SHALL BE SEALED WITH A UL APPROVED METHOD AND MATERIAL
APPROVED PER SPECIFICATIONS.
GENERAL CONSTRUCTION PERIOD STAGING OF WORK NOTES:
1. NORMAL WORK SHIFT HOURS FOR THE JAMES A. LOVELL FEDERAL HEALTH CARE CENTER CAMPUS IS 7:30 AM UNTIL 4:30 PM DAILY, MONDAY THROUGH FRIDAY.
2. CERTAIN WORK ITEMS AND CONSTRUCTION ACTIVITIES THAT CREATE NOISE, DUST, VIBRATIONS AND THAT WOULD CREATE DISTURBANCES TO THE MEDICAL CENTER AND/OR ANY OF THE ADJACENT OCCUPIED AREAS WILL NEED TO BE PERFORMED DURING PERIODS OF AFTER-HOURS/OFF-HOURS WORK. ITEMS THAT WILL REQUIRE AFTER HOURS ACTIVITIES SHALL BE FULLY COORDINATED AND APPROVED BY THE COR A MINIMUM OF TWO WEEKS PRIOR TO START OF
CONSTRUCTION.
3. AFTER-HOURS/OFF-HOURS OF OPERATIONS SHALL BE SCHEDULED FOR THE FOLLOWING DAYS AND TIMES AS COORDINATED, SCHEDULED AND AUTHORIZED BY
THE COR:
3.1. MONDAY THROUGH FRIDAY - 5:00 PM UNTIL 6:00 AM.
3.2. WEEKENDS (AS ALLOWED) - TIMES TO BE DETERMINED WITH THE COR AT LEAST TWO WEEKS PRIOR TO THE REQUESTED START TIMES.
4. THE FOLLOWING CONSTRUCTION ACTIVITIES SHALL BE CONSIDERED AFTER-HOURS/OFF-HOURS OPERATIONS:
4.1. THE MOVING OF CONSTRUCTION MATERIALS, EQUIPMENT, TOOLS AND/OR DEMOLITION MATERIALS TO/FROM THE EXTERIOR TO THE INTERNAL AREAS OF
WORK.
4.2. ALL WORK IN THE ADJACENT OCCUPIED SPACES TO THE CURRENT STAGE/AREA OF WORK.
4.3. ALL WORK THAT WILL REQUIRE SYSTEM SHUTDOWNS.
4.4. ALL CONCRETE OR METAL DECKING CORING, CUTTING OR DRILLING.
4.5. THE APPROVED USE OF POWER ACTUATED FASTENERS.
4.6. ALL WORK (DEMOLITION OR NEW) THAT WILL CAUSE IMPACT NOISE AND VIBRATIONS THAT CAN BE HEARD OR FELT IN THE SURROUNDING ADJACENT
OCCUPIED SPACES/AREAS.
4.7. CONTRACTOR MUST PARK WITHIN APPROVED CONSTRUCTION AREA OR AT DESIGNATED AREAS AT FAR PORTIONS OF EXISTING CAMPUS PARKING LOTS.
CAMPUS PARKING IS LIMITED AND PRIORITY IS GIVEN TO PATIENTS AND STAFF.
5. WEEKEND AND HOLIDAY HOURS SHALL BE FROM 8:00 AM TO 4:00 PM, OR AS APPROVED BY THE COR. COORDINATE WITH COR A MINIMUM OF TWO WEEKS PRIOR TO
START OF CONSTRUCTION.
6. CONTRACTOR SHALL OBTAIN DEFENSE BIOMETRIC IDENTIFICATION SYSTEM (DBIDS) PASSES OR DAY PASSES FOR ALL PERSONNEL FROM THE APPROPRIATE BASE
AUTHORITY HAVING JURISDICTION.
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
C O
L
O
R
A
D
O
L
I
C
E
N
S
E
D
A
R
C
H
I T
E
C
T
S E
Z
P
A
T
R
I C K
3/8/23
AI001
ARCHITECTURAL LEGENDS AND
GENERAL NOTES
SFTM
ALL
1. NEW 45-MINUTE-RATED WOOD DOOR W/ HM FRAME. - SEE
DOOR SCHEDULE
2. NEW GWB/METAL STUD 1 HR FIRE WALL, EXTEND TO BOTTOM
OF STRUCTURE OR HARDPAN CEILING. FIRESTOP ALL
PENETRATIONS.
3. INFILL OPENING TO MATCH EXIST WALL CONSTRUCTION.
4. EXISTING WALL –REPAIR ALL EXISTING HOLES IN SHEETROCK
AND FIRE CAULK ALL EXISTING PENETRATIONS TO MAKE INTO
A 1-HR FIRE WALL.
5. EXTEND EXISTING WALL UP TO B.O. STRUCTURE. NEW WALL
EXTENSION TO BE 1 HR. FIRE WALL.
6. LINE FULL LENGTH OF WALL WITH 3/4" FIRE-RETARDANT
PLYWOOD BACKERBOARD PANELS 4'W X 8'H.; MOUNT
PLYWOOD 12" ABOVE FINISH FLOOR TO ALLOW FOR
INSTALLATION OF RESILIENT BASE. PAINT PANELS FIRE
RESISTANT PAINT, HIGH-GLOSS WHITE - 2 COATS. LEAVE
STICKERS UNPAINTED OR REMOVE AND REAPPLY TO
CLEARLY INDICATE FIRE RATING. PAINT ALL REMAINING
WALLS AROUND AND ABOVE PLYWOOD.
7. ACCESS CONTROL, COORDINATE WITH TECHNOLOGY.
8. NOT USED
9. NOT USED
10. SERVER RACK - SEE TELECOM DWGS
11. COMPUTER ROOM A/C UNIT - SEE MECHANICAL DWGS.
12. NEW STATIC-DISSIPATIVE VINYL TILE FLOORING TO MEET ISTS
4.1.1 AND 4" RESILIENT BASE - SEE ROOM FINISH SCHEDULE
13. NOT USED
14. REPAIR/PAINT FLOORS AND WALLS AS REQUIRED AFTER
REMOVAL OF TECHNOLOGY EQUIPMENT.
15. WATERPROOF WALL PER DETAIL B1/A-301.
16. RELOCATED DRINKING FOUNTAIN, SEE MECHANICAL DWGS.
17. FILL REMOVED FLOOR TRENCH WITH CONCRETE AND LEVEL
WITH FLOOR AS REQUIRED FOR INSTALLATION OF NEW
FLOORING.
18. INSTALL NEW FIRE EXTINGUISHER CABINET.
REMODEL KEYED NOTES
1. REMOVE EXIST DOOR/FRAME/HW - PREP FOR NEW
DOOR/FRAME OR INFILL TO MATCH EXIST. WALL CONST - SEE
RENOVATION PLAN & DOOR SCHEDULE.
2. REMOVE EXIST DOOR LEAF/HW - EXIST. FRAME TO REMAIN
PREP - SEE RENOVATION PLAN.
3. DEMO PORTION OF EXIST. WALL FOR NEW DOOR OPENING -
SEE RENOVATION PLAN.
4. REMOVE EXISTING SUSPENDED ACOUSTICAL CEILING
ASSEMBLY IN ITS ENTIRETY
5. REMOVE EXIST. FINISH FLOORING AND 4" RESILIENT BASE.
PREP EXPOSED SUBSTRATE FOR NEW STATIC-DISSIPATIVE
TILE, SDT
6. NOT USED
7. DEMO EXIST. WALL - PATCH FLOOR AND WALLS AS REQ'D
FOR NEW FINISHES
8. REMOVE EXIST. WALL-MOUNTED PLYWOOD AND EQUIPMENT -
SEE TECHNOLOGY DWGS. FOR EQUIPMENT DEMO.
9. EXIST. ACCESS CONTROL - SEE TECHNOLOGY DWGS. FOR
RELOCATION AND REPLACEMENT
10. EXISTING EQUIPMENT RACK - SEE TECHNOLOGY DWGS. FOR
DEMO.
11. NOT USED
12. REMOVE EXIST. PLUMBING FIXTURE, SEE MECHANICAL.
13. REMOVE EXIST. COUNTERTOP.
14. REMOVE EXIST. OVERHEAD COILING DOOR AND ALL
ASSOCIATED TRACKS, HARDWARE, ETC.
15. REMOVE EXIST. GYPSUM BOARD CEILING IN ITS ENTIRETY.
16. REMOVE EXIST. ALUMINUM FLOOR TRENCH AND PREP FOR
INFILL. SEE MECH AND ELEC DRAWINGS FOR REMOVAL OF
UTILITIES FROM FLOOR TRENCH.
DEMOLITION NOTES
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
ARCHITECTURAL GENERAL NOTES
1. EXISTING STRUCTURAL GRIDS, BEAMS AND COLUMNS SHOWN
ARE FOR COORDINATION AND ORIENTATION PURPOSES ONLY
AND NOT FOR ACTUAL LOCATIONS OR SIZE OF COMPONENTS.
THE CONTRACTOR IS TO FIELD VERIFY LOCATIONS OF
COLUMNS AND STRUCTURAL MEMBERS / ELEMENTS.
2. THE AREAS OF WORK SHOWN ARE ASSOCIATED WITH AN
OPERATING FACILITY THAT MUST REMAIN IN SERVICE
24-HOURS A DAY, 7-DAYS A WEEK.
3. SCHEDULE WORK TO MINIMIZE DISRUPTION OF SERVICES.
4. COORDINATE WORK SCHEDULE WITH THE CONTRACTING
OFFICER'S REPRESENTATIVE (COR).
5. COORDINATE WORK WITH ALL OTHER TRADES. VERIFY ALL
EXISTING CONDITIONS PRIOR TO BEGINNING WORK TO
CONFIRM ACCURACY IN THE DRAWINGS. REPORT ANY
DISCREPANCIES TO THE VA COR.
6. DO NOT SCALE THE DRAWINGS. FIELD VERIFY ALL
DIMENSIONS AND EXISTING ARCHITECTURAL AND
STRUCTURAL CONDITIONS.
7. PROVIDE SMOOTH, LEVEL TRANSITIONS FROM NEW FINISH TO
EXISTING FINISH TO REMAIN.
8. GENERAL CONTRACTOR TO PROVIDE AND INSTALL ALL NEW
FINISHES TO COMPLETE THE WORK AS NECESSARY.
9. REMOVE AND REPLACE ELECTRICAL / DATA PLATES, BOXES,
LIGHTS AND ACCESSORIES AS NECESSARY. ADJUST
ELECTRICAL / DATA COMPONENTS AS NECESSARY.
10. PROTECT ADJACENT SURFACES TO REMAIN PRIOR TO
CONSTRUCTION. ANY DAMAGE MUST BE FIXED AT THE
CONTRACTORS EXPENSE.
11. THE GENERAL CONTRACTOR SHALL PROVIDE ICRA DUST
PARTITIONS PER INFECTION CONTROL AND ENVIRONMENTAL
PLANS, AND COORDINATED WITH THE COR PRIOR TO
CLOSING OFF AREAS OF WORK FROM ACTIVE AREAS OF THE
BUILDING.
12. ALL WALLS ARE DIMENSIONED TO FACE OF STUDS, UNLESS
NOTED OTHERWISE.
13. REFER TO MECHANICAL DRAWINGS FOR NEW MECHANICAL
UNITS AND WORK IN ROOMS.
14. REFER TO ELECTRICAL DRAWINGS FOR LIGHTING LOCATIONS
AND WORK IN ROOMS.
15. REFER TO TECHNOLOGY / TELECOM DRAWINGS FOR
TELECOM AND SERVER RACKS, CABLE TRAYS, CABLE JACK
LOCATIONS AND ITEMS RELATED TO TELECOM WORK.
16. REFER TO HAZARDOUS MATERIALS SPECIFICATIONS AND
NOTES ON ENVIRONMENTAL DRAWINGS FOR ABATEMENT
PROCEDURES OF HAZARDOUS MATERIALS.
17. EXISTING AND NEW CABLE TRAYS NOT SHOWN FOR CLARITY
OF ARCHITECTURAL SCOPE OF WORK. REFER TO
TECHNOLOGY / TELECOM DRAWINGS FOR INFORMATION
RELATED TO THESE ITEMS.
18. REFERENCE TECHNOLOGY / TELECOM DRAWINGS FOR
AREAS WHERE NEW DATA JACK WALL OUTLETS WILL BE
PROVIDED IN ROOMS OUTSIDE OF THE TELECOM ROOMS.
PATCH AND PAINT AROUND DATA JACK WALL OUTLET AS
NEEDED. COORDINATE PAINT COLOR WITH EXISTING WALL
COLOR AND VA COR.
19. FIRE-AND SMOKE-SEAL ALL THROUGH-WALL PENETRATIONS
TO COMPLY WITH FIRE-SMOKE RATING APPLICABLE TO WALL.
PROVIDE A MINIMUM OF 1-HOUR FIRE-SMOKE RATING WHERE
WALL RATING IS NOT SHOWN.
20. ALL HOLES THAT ARE LEFT IN ANY WALL AFTER REMOVAL OF
DUCTWORK, PLUMBING, ELECTRICAL, TECHNOLOGY, ETC.
MUST BE REPAIRED WITH GYPSUM BOARD AND TAPE OR
FILLED WITH FIRE CAULKING.
30 M SMOKE ZONE BARRIER
1 HR FIRE BARRIER
2 HOUR FIRE BARRIER
SMOKE RESISTIVE HAZARDOUS ENCLOSURE
30 M SMOKE ZONE BARRIER - EXISTING
1 HR FIRE BARRIER - EXISTING
2 HOUR FIRE BARRIER - EXISTING
SMOKE RESISTIVE HAZARDOUS ENCLOSURE
- EXISTING
FIRE EXTINGUISHER CABINET - NEW
FIRE EXTINGUISHER CABINET - EXISTING
FIRE RATED WALL LEGEND
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
NOTE: NOT ALL SYMBOLS USED
COLUMN NUMBER / GRID LINE
CENTER LINE
x'- x"
DIMENSION LINE
EXISTING TO BE REMOVED
EXISTING TO REMAIN
EXISTING TO REMAIN
NEW CONSTRUCTION
ROOM NAME
ROOM NAME
ROOM NUMBER
DOOR NUMBER SYMBOL
XX
X-XXX
1 Ref
A101
1 Ref
SHEET DETAIL IS DRAWN ON
DETAIL NUMBER
DETAIL NUMBER
ARCHITECTURAL ELEVATION
SHEET NUMBER
DETAIL NUMBER
X
X-XXX
SHEET NUMBER
ARCHITECTURAL SECTION
R e f
R e f
AB
ACT
ACST
ADJ
AFF
AHU
ALT
AL
ALC
APPROX
ARCH
ATS
BD
BLDG
BLK
BM
BOT
BRG
BSMT
C
CAP
CC
CD
CCT
CEM
CG
CH
CI
CIP
CIR
CJ
CKT
C
L
CLN
CLG
CLR
CMP
CMPA
CMU
CND,C
CNDS
CO
COL
COMM
CONC
COND
CONN
CONST
CONT
CONV
CP
CR
CS
CT
CT
CTR
CTS
CW
CPT
DET, DTL
DIA
DIM
DMPR
DN
DP
DS
DW
DWG
EA
EF
EG
EJ
ELEV
ELEC
EMER
EPDM
EQ
EQUIP
EW
EWC
EXH
EXIST
EXP
EXP JT
CELSIUS
CAPACITY
CENTER TO CENTER
CEILING DIFFUSER
CUBICAL CURTAIN TRACK
CEMENT
CORNER GUARD
CAST IRON, COURTYARD INLET
CHILLER
CAST IRON PIPE
CIRCULATING
CONTROL JOINT
CIRCUIT
CENTERLINE
CLEAN
CEILING
CLEAR
CORRUGATED METAL PIPE
CORRUGATED METAL PIPE ARCH
CONCRETE MASONRY UNITS
CONDUIT
CONDENSATE
CLEANOUT
COLUMN
COMMUNICATION
CONCRETE
CONDUCTOR
CONNECTION
CONSTRUCTION
CONTINUOUS
CONVERTER
NONREINFORCED CONCRETE PIPE
CHAIR OR CRASH RAIL
CONCRETE SEALER/SURFACE
CERAMIC TILE, CURRENT TRANSFORMER,
COOLING TOWER
CENTER, COOLING TOWER RETURN
COOLING TOWER SUPPLY
COLD WATER
CARPET
DETAIL
DIAMETER
DIMENSION
DAMPER
DOWN
DISTRIBUTION PANEL
DOWNSPOUT, STORM DRAINAGE STRUCTURE
DOMESTIC WATER
DRAWING
EACH
EACH FACE, EXHAUST FAN
EXHAUST GRILLE
EXPANSION JOINT
ELEVATION
ELECTRIC, ELECTRICAL CLOSET
EMERGENCY
EPDM ROOF MEMBRANE
EQUAL
EQUIPMENT
EACH WAY
ELECTRIC WATER COOLER
EXHAUST
EXISTING
EXPANSION, EXPOSED
EXPANSION JOINT
ANCHOR BOLT, AUGER BORING
ACOUSTIC TILE
ACOUSTIC
ADJUSTABLE
ABOVE FINISHED FLOOR
ALTERNATE
AIR HANDLING UNIT
ALUMINUM
ALCOVE
APPROXIMATE
ARCHITECTURAL
AUTOMATIC TRANSFER SWITCH
BOARD
BUILDING
BLOCK
BEAM
BOTTOM
BEARING
BASEMENT
GA
GALV
GFI
GL
GWB
GYP
HGT, H
HB
HC
HDW
HORIZ
HR
HSKP
INT
INSUL
INV
JB
JC
JCT
JT
KO
KVA
KW
L
LT
LAV
M
MAS
MATL
MAX
MECH
MET/MTL
MH
MIN
MISC
MM
MTD
MTG
MWP
MULL
NA
NEC
NEG
NEUT
NIC
NOM
NTS
OA
OC
OD
OF
OPNG
OPP
OH, OVHD
P
PB
PIV
PL
PLYWD
PNL
PNT
PP
PRELIM
PRIM
PT
PTN
GAGE
GALVANIZED
GROUND FAULT INTERRUPT
GLASS
GYPSUM WALL BOARD
GYPSUM
HEIGHT, HUMIDIFIER
HOSE BIBB
HANDICAPPED
HARDWARE
HORIZONTAL
HOUR, HAND RAIL
HOUSEKEEPING
INTERIOR
INSULATION, INSULATED
INVERT
JUNCTION BOX
JANITOR CLOSET
JUNCTION
JOINT
KNOCK OUT
KILOVOLT-AMPERE
KILOWATT
LOUVER, LENGTH, LENGTH OF CURVE
LIGHT
LAVATORY VERTICAL
METER, MEGA
MASONRY
MATERIAL
MAXIMUM
MECHANICAL
METAL
MANHOLE
MINIMUM, MINUTE
MISCELLANEOUS
MILLIMETER
MOUNTED
MOUNTING
MEMBRANE WATERPROOFING
MULLION
NOT APPLICABLE
NATIONAL ELECTRIC CODE
NEGATIVE
NEUTRAL
NOT IN CONTRACT
NOMINAL
NOT TO SCALE
OUTSIDE AIR
ON CENTER
OUTSIDE DIAMETER
OVERFLOW DRAIN
OPENING
OPPOSITE
OVERHEAD
PIPE, POLE
PULL BOX
POST INDICATOR VALVE
PLATE
PLYWOOD
PANEL
PAINT
PUSH-PLATE
PRELIMINARY
PRIMARY
POINT, POINT OF TANGENT
PARTITION
FA
FD
FDN
FDR
FE
FEC
FFE
FIG
FIN
FL
FLUOR
FRAME
FTG
FXTR
FIRE ALARM
FLOOR DRAIN, FIRE DAMPER
FOUNDATION
FEEDER
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISHED FLOOR ELEVATION
FIGURE
FINISH
FLOOR, FLASHING, FLOW LINE
FLUORESCENT
FRAME
FOOTING
FIXTURE
PVMT
PVC
PVC
R
RA
RAD
RVB
RCP
RCP
RECP
REINF
REG
REQD
REV
RF
RHC
RM
RPM
RVT
SAN
SCH
SD
SECT
SG
SH
SIM
1 PH
SL
SP
SPDT
SPEC
SPST
SQ
SR
SS
ST
STA
STD
STL
STRUC
SUP
SUSP
SV
SW
SWBD
SWGR
T
T&B
TEL
TEMP
TERM
3/C
3/P
3 WAY
TO
TRANS
TS
TV
TW
TYP
UH
V
VA
VAC
VCT
VENT
VERT
VEST
VS
VTR
VWC
W
W
WA
W/
W/O
WC
WD
WG
WP
WS
WT
WWF
POINT OF VERTICAL CURVE
POLY VINYL CHLORIDE
PAVEMENT
RADIUS, RISER, RUBBER SHEATH
RETURN AIR
RADIUS
RESILIENT VINYL BASE
REINFORCED CONCRETE PIPE
REFLECTED CEILING PLAN
RECEPTACLE
REINFORCEMENT
REGULATOR, REGISTER
REQUIRED
REVISION
ROOF, RETURN FAN
REHEAT COIL
ROOM
REVOLUTIONS PER MINUTE
RESILIENT VINYL TILE
SANITARY SEWER
SCHEDULE
SPLITTER DAMPER, STORM DRAIN
SECTION
SUPPLY GRILLE
SHEET
SIMILAR
SINGLE PHASE
SLOPE
STATIC PRESSURE, SINGLE POLE
SINGLE POLE, DOUBLE THROW
SPECIFICATION
SINGLE POLE, SINGLE THROW
SQUARE
SUPPLY REGISTER
SANITARY SEWER
STEAM, SINGLE THROW, STREET, STAFF
STATION
STANDARD
STEEL
STRUCTURAL
SUPPORT
SUSPENDED
SHEET VINYL
SWITCH, SIDEWALK
SWITCHBOARD
SWITCHGEAR
TILE,TOP,TANGENT
TOP AND BOTTOM
TELEPHONE
TEMPERATURE, TEMPORARY
TERMINAL
THREE CONDUCTOR
THREE POLE
THREE WAY
TOP OF
TRANSITION
TOP OF STEEL, TOP OF STONE, TOP OF SLAB
TELEVISION
TOP OF WALL
TYPICAL
UNIT HEATER
VENT,VOLT,VALVE
VOLT AMPRE
VACUUM
VINYL COMPOSITION TILE
VENTILATING
VERTICAL
VESTIBULE
VENT STACK
VENT THRU ROOF
VINYL WALL COVERING
WIDTH,WASTE,WATER,WATT,WEST, WIRE,
WATER LINE STRUCTURE
WATT
WITH
WITHOUT
WATER CLOSET, WHEEL CHAIR
WIDTH, WINDOW DIMENSION
WALL GUARD
WATERPROOF, WEATHERPROOF
WASTE STACK, WATER SURFACE, WATERSTOP, WALL SWITCH
WEIGHT
WELDED WIRE FABRIC
CAST-IN-PLACE CONCRETE /
PRECAST CONCRETE
CONCRETE MASONRY
CONTINUOUS WOOD FRAMING
WOOD BLOCKING
FIBROUS INSULATION
GYPSUM BOARD
ROOF INSULATION
RIGID INSULATION
ALUMINUM
BRICK MASONRY
STEEL
EARTH
ARCHITECTURAL LEGEND
MATERIAL LEGEND
FIRESTOPPING GENERAL NOTES
1. MAINTAIN FIRE RATED CONSTRUCTION AT WALL
PENETRATIONS. CONSTRUCTION IS TO CONFORM TO
MANUFACTURERS' FIRE RATED / TEST ASSEMBLIES.
2. FIRE CAULK ALL SLEEVES AND PENETRATIONS AT FIRE WALLS /
PARTITIONS AND FLOORS. CONFORM WITH THE TESTED /
SUBMITTED FIRE RATED ASSEMBLY. USE RED FIRE CAULK AND
LABEL WALL WITH U.L. DESIGNATION NUMBER. FIRE RATED
WALLS SHOWN ON PLANS.
3. PATCH AND REPAIR ALL EXISTING FIREPROOFING ON EXISTING
STRUCTURAL MEMBERS, INCLUDING THAT WHICH IS
UNCOVERED NEEDING REPAIR AND THAT WHICH IS DISTURBED
DURING CONSTRUCTION.
4. PATCH AND REPAIR ALL EXISTING FIRE CAULKING AT EXISTING
RATED WALLS WHICH IS UNCOVERED NEEDING REPAIR AND
THAT WHICH IS DISTURBED DURING CONSTRUCTION.
RE-LABEL EXISTING WALL IF NECESSARY.
ARCHITECTURAL ABBREVIATIONS
NOT ALL ABBREVIATIONS ARE
USED
2021 NFPA 101, LIFE SAFETY CODE
2022 NFPA 13, STANDARD FOR THE INSTALL ATION OF SPRINKLER SYSTEMS
2020 NFPA 25, STANDARD FOR THE INSPECTION, TESTING, AND MAINTENANCE OF WATER-
BASED FIRE PROTECTION SYSTEMS
2020 NFPA 70, NATIONAL ELECTRICAL CODE
2022 NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE
2020 NFPA 75, STANDARD FOR THE FIRE PROTECTION OF INFORMATION TECHNOLOGY
EQUIPMENT
2021 INTERNATIONAL BUILDING CODE (IBC) WHERE NFPA 101 AND ASSOCIATED DOCUMENTS
ARE SILENT
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL FIRE CODE (IFC), WHERE NFPA STANDARDS AND CODES ARE SILENT
2021 INTERNATIONAL MECHANICAL CODE (IMC)
2021 INTERNATIONAL FUEL GAS CODE (IFGC)
2021 UNIFORM PLUMBING CODE
2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES (ICC/ANSI 117.1)
APPLICABLE CODES AND ORDINANCES
2021 INFRASTRUCTURE STANDARD FOR TELECOMMUNICATIONS SPACES (VERSION 3.1)
2015 ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS
2017 VA BARRIER FREE DESIGN STANDARD
VA TILL AND DESIGN GUIDES
2022 NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS
TR
G50
COMM
G80
LARGE
WAITING
G67
LARGE
EXAM
G69
LARGE
EXAM
G71
SMALL
EXAM
G73
SMALL
KENNEL
G75
CORR
G74
STORAGE
G48
LARGE
KENNEL
G76
CONFERENCE/
STAFF
LOUNGE
G77
COURTYARD
STORAGE
G48A
CORRIDOR
G78
RECEPTION
G68
PHARM
G70
DOCTOR OFFICE
G72
OFFICE
G79
OFFICE
G79A
QUARANTINE
G83
QUARANTINE
G84
DECONTAMINATION
G86
VESTIBULE
G82
CORRIDOR
G81
CORRIDOR
G88
JAN
G85
DRY
STO
G90
FEED
COOLER
G90A
CLEANED
WASTE
HOLDING
G91
FEED
PREP
G89
CLEAN
STORAGE
G87
RECEIVING/
EXAM/
WASH AREA
G92
CORR
G96
F TLT
G93
F SHOWER
G94
M TLT/
SHOWER
G95
CORR
G65
VEST
G64
TOILET
G63
PROCEDURE
G61
STORAGE
G62
SUB-
STERILE
G58
SCRUB
G59
OR
G60
X-RAY/
PRE-OP/
POST-OP
G56
CORRIDOR
G51
LAUNDRY/
STORAGE
G52
JAN
G55
DARK
ROOM
G57
TLT
G53
NECROPSY
G54
GAS
MAINFOLD
G97
MED/LAB
AIR
G98
STAIR
G64A
SMALL
WAITING
G66
CORRIDOR
G46
STAIR
G64A
TOILET
OPEN
OFFICE
OFFICE
OFFICE
MECH
STORAGE
OPEN
SPACE
TR
G50
CORR
G65
TR
G50
CORR
G65
COMM
G80
JAN
G85
COMM
G80
JAN
G85
ROOM G50
100.8 SF
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
C O
L
O
R
A
D
O
L
I
C
E
N
S
E
D
A
R
C
H
I T
E
C
T
S E
Z
P
A
T
R
I C K
3/8/23
43H.A-101
FIRST FLOOR PLAN
SFTM
43H
ROOM G80
37.0 SF
SCALE: 1/4" = 1'-0"
EXISTING TR - G50 - DEMO PLAN
F1
SCALE: 1/4" = 1'-0"
TR - G50 - REMODEL PLAN
F3
SCALE: 1/4" = 1'-0"
EXISTING TR - G80 - DEMO PLAN
F5
43H.A-101
F1&F3
43H.A-101
F5&F7
NORTH
0' 4' 8' 16' 32'
1/8"=1'-0"
0' 2' 4' 8' 16'
1/4"=1'-0"
SCALE: 1/4" = 1'-0"
TR - G80 - REMODEL PLAN
F7
SCALE: 1/8"=1'-0"
FIRST FLOOR PLAN -B43H
D5
SCALE: 1/8"=1'-0"
SECOND FLOOR PLAN -B43H
D3
ALL WALLS
1. NEW 45-MINUTE-RATED WOOD DOOR W/ HM FRAME. - SEE
DOOR SCHEDULE
2. NEW GWB/METAL STUD 1 HR FIRE WALL, EXTEND TO BOTTOM
OF STRUCTURE OR HARDPAN CEILING. FIRESTOP ALL
PENETRATIONS.
3. INFILL OPENING TO MATCH EXIST WALL CONSTRUCTION.
4. EXISTING WALL –REPAIR ALL EXISTING HOLES IN SHEETROCK
AND FIRE CAULK ALL EXISTING PENETRATIONS TO MAKE INTO
A 1-HR FIRE WALL.
5. EXTEND EXISTING WALL UP TO B.O. STRUCTURE. NEW WALL
EXTENSION TO BE 1 HR. FIRE WALL.
6. LINE FULL LENGTH OF WALL WITH 3/4" FIRE-RETARDANT
PLYWOOD BACKERBOARD PANELS 4'W X 8'H.; MOUNT
PLYWOOD 12" ABOVE FINISH FLOOR TO ALLOW FOR
INSTALLATION OF RESILIENT BASE. PAINT PANELS FIRE
RESISTANT PAINT, HIGH-GLOSS WHITE - 2 COATS. LEAVE
STICKERS UNPAINTED OR REMOVE AND REAPPLY TO
CLEARLY INDICATE FIRE RATING. PAINT ALL REMAINING
WALLS AROUND AND ABOVE PLYWOOD.
7. ACCESS CONTROL, COORDINATE WITH TECHNOLOGY.
8. NOT USED
9. NOT USED
10. SERVER RACK - SEE TELECOM DWGS
11. COMPUTER ROOM A/C UNIT - SEE MECHANICAL DWGS.
12. NEW STATIC-DISSIPATIVE VINYL TILE FLOORING TO MEET ISTS
4.1.1 AND 4" RESILIENT BASE - SEE ROOM FINISH SCHEDULE
13. NOT USED
14. REPAIR/PAINT FLOORS AND WALLS AS REQUIRED AFTER
REMOVAL OF TECHNOLOGY EQUIPMENT.
15. WATERPROOF WALL PER DETAIL B1/A-301.
16. RELOCATED DRINKING FOUNTAIN, SEE MECHANICAL DWGS.
17. FILL REMOVED FLOOR TRENCH WITH CONCRETE AND LEVEL
WITH FLOOR AS REQUIRED FOR INSTALLATION OF NEW
FLOORING.
18. INSTALL NEW FIRE EXTINGUISHER CABINET.
REMODEL KEYED NOTES
1. REMOVE EXIST DOOR/FRAME/HW - PREP FOR NEW
DOOR/FRAME OR INFILL TO MATCH EXIST. WALL CONST - SEE
RENOVATION PLAN & DOOR SCHEDULE.
2. REMOVE EXIST DOOR LEAF/HW - EXIST. FRAME TO REMAIN
PREP - SEE RENOVATION PLAN.
3. DEMO PORTION OF EXIST. WALL FOR NEW DOOR OPENING -
SEE RENOVATION PLAN.
4. REMOVE EXISTING SUSPENDED ACOUSTICAL CEILING
ASSEMBLY IN ITS ENTIRETY
5. REMOVE EXIST. FINISH FLOORING AND 4" RESILIENT BASE.
PREP EXPOSED SUBSTRATE FOR NEW STATIC-DISSIPATIVE
TILE, SDT
6. NOT USED
7. DEMO EXIST. WALL - PATCH FLOOR AND WALLS AS REQ'D
FOR NEW FINISHES
8. REMOVE EXIST. WALL-MOUNTED PLYWOOD AND EQUIPMENT -
SEE TECHNOLOGY DWGS. FOR EQUIPMENT DEMO.
9. EXIST. ACCESS CONTROL - SEE TECHNOLOGY DWGS. FOR
RELOCATION AND REPLACEMENT
10. EXISTING EQUIPMENT RACK - SEE TECHNOLOGY DWGS. FOR
DEMO.
11. NOT USED
12. REMOVE EXIST. PLUMBING FIXTURE, SEE MECHANICAL.
13. REMOVE EXIST. COUNTERTOP.
14. REMOVE EXIST. OVERHEAD COILING DOOR AND ALL
ASSOCIATED TRACKS, HARDWARE, ETC.
15. REMOVE EXIST. GYPSUM BOARD CEILING IN ITS ENTIRETY.
16. REMOVE EXIST. ALUMINUM FLOOR TRENCH AND PREP FOR
INFILL. SEE MECH AND ELEC DRAWINGS FOR REMOVAL OF
UTILITIES FROM FLOOR TRENCH.
DEMOLITION NOTES
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
NO ARCHITECTURAL
WORK ON THIS FLOOR
"FOR CONTRACTOR
REFERENCE ONLY"
B1
43H.A-301
B3
43H.A-301
CAN'T ENLARGE
DOOR DUE TO CMU
WALLS
G50
FULLY SPRINKLERED
AutoCAD SHX Text
DUMPSTER
AutoCAD SHX Text
PIT
AutoCAD SHX Text
FEC
http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html http://www.2learncad.com/free_cad_blocks.html
Second Floor 114' - 0"
First Floor 100' - 0"
TR
G50
TR
G50
EXIST. CONCRETE FLOOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
3/8/23
43H.A-301
SECTIONS AND DETAILS
SFTM
43H
0' 2' 4' 8' 16'
1/4"=1'-0"
SCALE: 1/4"=1'-0"
BUILDING SECTION -B43HB1
6 ALL WALLS
REMODEL KEYED NOTES
DEMOLITION NOTES
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
SCALE: 1/4"=1'-0"
BUILDING SECTION -B43HB3
EXIST. CMU WALLS
EXIST. CONCRETE FLOOR
EXIST. CEILING
FULLY SPRINKLERED
MECH
ROOM
B03
STORAGE
B02
STO
B06
MECH
ROOM
B04
STORAGE
B10
STORAGE
B05
STORAGE
B07
STORAGE
B08A
STORAGE
B08B
STORAGE
B08C
STORAGE
B09
VESTIBULE
B08
ELEV
BELEV2
STAIR
BST2
STAIR
BST1
STORAGE
B01
ELEC
ROOM
B13
ELECTRICAL
ROOM
B14
FREIGHT
ELEV
BELEV3
MECHANICAL
ROOM
B11
BOILER
ROOM
ENTRY
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
3/8/23
81H.A-101
BASEMENT FLOOR PLAN
SFTM
81H
SCALE: 1/8" = 1'-0"
BASEMENT FLOOR PLAN -B81HD3
0' 4' 8' 16' 32'
1/8"=1'-0"
NO ARCHITECTURAL
WORK ON THIS FLOOR
"FOR CONTRACTOR
REFERENCE ONLY"
NORTH
FULLY SPRINKLERED
133-B
COMM
TR
ADMINISTRATIVE
SPACE
ENTRY
ADMINISTRATIVE
OFFICE
MECH
ROOM
REFRIGERATOR
133A
WAREHOUSE
OFFICE
STAIR
1ST4
MECH
ROOM
OFFICE
136A
FREIGHT
ELEV
1ELEV3
STORAGE
133B
STORAGE
133C
ELEV
1ELEV2
STORAGE
133D
STAIR
1ST3
STORAGE
130A
STORAGE
AREA
CORRIDOR
ADMINISTRATIVE
OFFICE
COOLER
129A
COOLER
ADMINISTRATIVE
OFFICE
ADMINISTRATIVE
OFFICE
RECEIVING
LOADING
AREA
M/F TLT
125A
SHWR RM
RECEIVING
STAIR
1ST1
CLO
113A
VESTIBULE
ELEVATOR
1ELEV1
OFFICE
CORR
STAIR
1ST2
CORR
VAULT
MAIL RM
LOUNGE
M TLT
JAN
107A
F TLT
104A
FOYER
STORAGE
AREA
MECH
CLO
OFFICE
OFFICE
ELEC
ROOM
133-A
COMM
VAULT
COMM
VAULT
TR
ELEC
ROOM
133-A
TR
133-B
TR
ELEC
ROOM
133-A
ROOM 116
38.8 SF
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
3/8/23
81H.A-102
FIRST FLOOR PLAN
SFTM
81H
SCALE: 1/8" = 1'-0"
FIRST FLOOR PLAN -B81HF3
ROOM 102
45.2 SF
SCALE: 1/4" = 1'-0"
EXISTING TR - 116 - DEMO PLANB7
0' 4' 8' 16' 32'
1/8"=1'-0"
0' 2' 4' 8' 16'
1/4"=1'-0"
SCALE: 1/4" = 1'-0"
TR - 116 - REMODEL PLANB9
SCALE: 1/4" = 1'-0"
EXISTING TR - 102 - DEMO PLAND7
SCALE: 1/4" = 1'-0"
TR - 133-B - REMODEL PLANF7
ROOM 133-A
111.6 SF
81H.A-102 D7&F7
81H.A-102 B7&B9
6ALL WALLS
REMODEL KEYED NOTES
DEMOLITION NOTES
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
NOT ALL KEYED NOTES ARE
USED ON EVERY SHEET
133-B
NO ARCHITECTURAL
WORK IN THIS ROOM
"FOR CONTRACTOR
REFERENCE ONLY"
NO ARCHITECTURAL
WORK IN THIS ROOM
"FOR CONTRACTOR
REFERENCE ONLY"
NORTH
FULLY SPRINKLERED
WAREHOUSE
LABORATORY
203A
ADMINISTRATIVE
OFFICE
STORAGE
VESTIBULE
STAIRS
2ST1
STORAGE
ADMINISTRATIVE
OFFICE
WAREHOUSE
OFFICE
202B
OFFICE
202A
MECH
ROOM
ELEV
2ELEV1 STAIRS
2ST2
STORAGE
MEN
WOMEN
HALL
HALL
OFFICE
CONF
OFFICE
OFFICE
OFFICE
OFFICE
OPEN
OFFICE
COPY
BREAK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
North Chicago, IL
556-21-700
Project Director
07/14/2023Revisions: Date:
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
ADDENDUM
VCI Project Management Construction Management Engineering
ADDENDUM 1 07/14/2023
3/8/23
81H.A-103
SECOND FLOOR PLAN
SFTM
81H
SCALE: 1/8" = 1'-0"
SECOND FLOOR PLAN -B81HF3
0' 4' 8' 16' 32'
1/8"=1'-0"
0' 2' 4' 8' 16'
1/4"=1'-0"
NO ARCHITECTURAL
WORK ON THIS FLOOR
"FOR CONTRACTOR
REFERENCE ONLY"
NORTH
FULLY SPRINKLERED
Second Floor 112' - 0"
First Floor 100' - 0"
Basement Floor 90' - 8"
Roof 124' - 0"
TR
133-B
TR
133-B
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
ADDENDUM
(ISSUED FOR BID AND
CONSTRUCTION)
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
EHRM…
This is the start of the file's text. The full file is on GovTribe.