This is a summary of an attachment to a federal contract solicitation. The attachment is for EHRM infrastructure upgrades for the Department of Veterans Affairs Technology Acquisition Center in Chicago, Illinois. The related solicitation, number 36C77623B0063, seeks proposals for upgrades to the EHRM infrastructure system. Offerors should respond by the specified deadline to upgrade and maintain the EHRM system, including necessary hardware, software, and support services. Pricing is to be provided for a one year base period and four one-year options. The solicitation is set aside for small businesses. The incumbent contractor was not specified. Responses are due by the date listed on the federal contracting website for this opportunity from the Department of Veterans Affairs Technology Acquisition Center.
View the file
Other files for this federal contract opportunity
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNOLOGY SYMBOL LIST
SYMBOL: DESCRIPTION: NOTE:
EQUIPMENT
LIST ABBREV.:
#D
W
#D#V 1.
WALL INFORMATION OUTLET, COMBINATION
TELEPHONE/DATA COMMUNICATION
SC-IO-W
1.WALL INFORMATION OUTLET, WALL TELEPHONESC-IO-W
1.
FLOOR INFORMATION OUTLET, DATA COMMUNICATION
ONLY
SC-IO-F
WAP
1.
CEILING INFORMATION OUTLET, DATA
COMMUNICATION ONLY, WIRELESS ACCESS POINT
SC-IO-C
#D#V 1.
FLOOR INFORMATION OUTLET, COMBINATION
TELEPHONE/DATA COMMUNICATION
SC-IO-F
#D 1.
CEILING INFORMATION OUTLET, DATA
COMMUNICATION ONLY
SC-IO-C
#D 1.
WALL INFORMATION OUTLET, DATA COMMUNICATION
ONLY
SC-IO-W
M
T
2.CARD READER (ROUGH-IN ONLY)N/A
CSS 2.CONTROLLED SECURITY SCHEME SCHEDULE
IDENTIFIER
N/A
TECHNOLOGY GENERAL NOTES:
1. ###-### INDICATES TECHNOLOGY EQUIPMENT SCHEDULE ITEM LABELED AS "EQUIPMENT
LIST ABBREVIATION"
2. REFER TO TECHNOLOGY EQUIPMENT SCHEDULE AND SPECIFICATIONS FOR FULL
DESCRIPTIONS AND MANUFACTURERS OF ALL DEVICES.
TECHNOLOGY MOUNTING SUBSCRIPT KEY:
A MOUNT AT +6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH
H MOUNT ORIENTED HORIZONTALLY
L MOUNT IN CASEWORK
M MOUNT IN MODULAR FURNITURE
S MOUNT IN SURFACE RACEWAY
A SLASH IS USED BETWEEN TWO SUBSCRIPTS, E.G., A/H.
1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR
ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS
ON THIS PAGE FOR ADDITIONAL INFORMATION.
2. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, ABOVE CEILING, IN FLOOR SLAB, ETC.
UNLESS OTHERWISE INDICATED ON THE PLANS OR IN THE SPECIFICATIONS. CONDUIT IN
MECHANICAL ROOMS AND STORAGE ROOMS WITHOUT CEILINGS MAY BE EXPOSED ON
BUILDING STRUCTURE.
3. BOXES LOCATED ON OPPOSITE SIDES OF NON-RATED WALLS SHALL BE OFFSET A MINIMUM
OF 6" HORIZONTALLY. BOXES ON OPPOSITE SIDES OF FIRE RATED WALLS SHALL BE
OFFSET A MINIMUM OF 24" HORIZONTALLY. "THRU-THE-WALL" BOXES SHALL NOT BE
ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER.
4. VERIFY ALL FURNITURE, MODULAR FURNITURE, AND EQUIPMENT LOCATIONS WITH
ARCHITECTURAL PLANS, ELEVATIONS, AND REVIEWED SHOP DRAWINGS. PRIOR TO MAKING
THE ACTUAL TELECOMMUNICATIONS INSTALLATION, ADJUST OUTLETS OR CONNECTION
LOCATIONS TO ACCOMMODATE FURNITURE AND/OR EQUIPMENT.
5. TELECOMMUNICATIONS EQUIPMENT SHALL BE MOUNTED TO ALLOW ACCESS TO
ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF TELECOMMUNICATION
DEVICES ON EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR SHALL BE APPROVED IN
ADVANCE BY THE OTHER CONTRACTOR.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL
OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE
EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR
SEALED INTO OPENINGS.
7. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL
BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF
THROUGH-PENETRATION FIRESTOPS. REFER TO DIVISION 7 FOR ADDITIONAL INFORMATION
AND REQUIREMENTS SPECIFIC TO FIRESTOPPING.
8. THE TECHNOLOGY CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF
THE CEILINGS, CEILING TILES, AND CEILING GRID ASSOCIATED WITH THE AREAS OF WORK
BY ALL CONTRACTORS.
9. ALL LADDER RACK AND CABLE TRAY SIZES ARE AS DEFINED ON THE DRAWINGS. REFER TO
SPECIFICATION SECTION 27 05 36 FOR APPROVED MANUFACTURERS AND INSTALLATION
REQUIREMENTS. PROTECT BEND RADIUS OF CABLE BY ADDING WATERFALL FOR
TRANSITIONING OF CABLE TRAY TO RACK.
10. FLUSH MOUNT ALL TELECOMMUNICATION OUTLETS AT +18" FROM FLOOR (CENTERLINE
DIMENSION), EXCEPT WHERE OTHERWISE NOTED. OUTLETS MAY BE SURFACE MOUNTED
WHEN CONDUIT IS SPECIFIED EXPOSED.
11. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO THE
WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES
DAMAGE IS RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE
RATING, AND FINISH.
12. ALL ADDITIONAL FLOOR SLEEVES SHALL REQUIRE THE CONTRACTOR TO SCAN THE FLOOR
PRIOR TO CORING. NO WORK SHALL PROCEED WITHOUT VERIFICATION THE CORE
LOCATION IS CLEAR OF CONDUIT WITHIN THE DECK.
13. TEMPORARY FIRESTOPPING COMPOSED OF MINERAL WOOL SHALL BE INSTALLED IN ALL
WALL AND FLOOR PENETRATIONS AT THE END OF EVERY WORK SHIFT WHILE WORK IS IN
PROGRESS. UN-SEALED OPENINGS ARE NOT ALLOWED TO PROVIDE PROTECTION AGAINST
FIRE/SMOKE SPREAD THROUGH UN-SEALED PENETRATIONS.
14. RE-INSTALL CEILING TILES AT THE END OF EVERY WORK SHIFT DURING CABLE
INSTALLATION.
15. ALL BACKBOX INSTALLED IN A FIRE-RATED WALL SHALL BE INSTALLED WITH FIRE PUTTY
PADS.
TECHNOLOGY INSTALLATION NOTES:
1. THE EXISTING DATA NETWORK IS TO REMAIN OPERATIONAL DURING THE INSTALLATION OF
THE NEW TELECOM ROOM EQUIPMENT. THE SYSTEM SHALL NOT BE DISRUPTED UNLESS
COORDINATED IN ADVANCE WITH THE OWNER AND ENGINEER AND AT THEIR DISCRETION
ON DATE AND TIME.
2. REFER TO THE DRAWINGS FOR THE LOCATIONS OF THE NEW TELECOM ROOM HEADEND
EQUIPMENT AND THE EXISTING TELECOM ROOM EQUIPMENT LOCATIONS.
3. CONSTRUCT NEW TELECOMMUNICATIONS ROOMS AND/OR EXPAND EXISTING TO REMAIN
TELECOMMUNICATIONS ROOMS. RENOVATION AND CONSTRUCTION OF NEW
TELECOMMUNICATION ROOMS SHALL BE COMPLETED AT THE START OF THE PROJECT.
4. FUSION SPLICE THE EXISTING FIBER FROM THE EXISTING INCOMING LOCATION AS
IDENTIFIED IN THE FIBER DIAGRAM. MAINTAIN THE EXISTING FIBER AND FEEDS TO THE
EXISTING TELECOMMUNICATIONS ROOM AS CURRENTLY CONSTRUCTED UNTIL THE END OF
THE PROJECT.
5. ROUTE NEW FIBER TO THE NEW TELECOMMUNICATIONS ROOMS. IN EXISTING TO REMAIN
TELECOMMUNICATIONS ROOMS, ROUTE A NEW FIBER BACKBONE TO THE NEW CLOSET
LOCATIONS. MAINTAIN THE EXISTING ROOMS AND FIBER BACKBONE CABLING UNTIL THE
AREA BEING SERVED BY EACH RESPECTIVE TELECOMMUNICATIONS ROOM HAS BEEN RE-
FED.
6. PROVIDE NEW A/B POWER PANELS, HVAC, AND GROUNDING IN NEW AND EXISTING TO
REMAIN ROOMS. POWER ALL TELECOMMUNICATIONS ROOM LOADS FROM THE NEW PANELS.
7. FOR NEW OR EXPANDED TELECOMMUNICATIONS ROOMS, PROVIDE NEW CABLES FROM THE
EXISTING OUTLETS TO THE NEW ROOMS. REMOVE ALL EXISTING CABLING AFTER NEW
CABLES HAVE BEEN PULLED TO THE OUTLETS TO MAINTAIN OPERATIONAL CAPABILITY OF
THE SPACES TO THE GREATEST EXTENT POSSIBLE.
8. AFTER NEW CABLING HAS BEEN INSTALLED, REMOVE EXISTING BACKBONE CABLING IN
TELECOMMUNICATIONS ROOMS BEING ABANDONED.
9. REFER TO THE TECHNOLOGY DEMOLITION NOTES FOR ADDITIONAL REQUIREMENTS.
TECHNOLOGY PHASING NOTES
GENERAL NOTES:
1. ALL SYMBOLS AND ABBREVIATIONS LISTED MAY NOT BE APPLICABLE TO THIS PROJECT.
REFER TO THE GENERAL TECHNOLOGY EQUIPMENT SCHEDULE FOR MORE COMPLETE
DESCRIPTION AND ITEMS.
2. ALL SYMBOLS AND ABBREVIATIONS REFER TO TECHNOLOGY SHEETS ONLY AS DEFINED ON
THE SHEET INDEX. REFER TO THE TECHNOLOGY NOTES FOR ADDITIONAL INFORMATION.
3. ALL SYMBOLS LISTED ABOVE ARE FOR REFERENCE ONLY. REFER TO PLANS AND LINE TYPE
KEY FOR NEW, EXISTING TO REMAIN AND TO BE REMOVED ITEMS FOR ADDITIONAL
INFORMATION.
4. REFER TO RISERS ON SHEET(S): TN601.
TECHNOLOGY SYMBOL NOTES:
1. "#V/#D" INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION. REFER TO
INFORMATION OUTLET SCHEDULE ON TN701 AND F1/TN502 FOR ADDITIONAL INFORMATION.
2. ROUGH-IN ONLY. REFER TO DETAIL E8/TN501 FOR ROUGH-IN REQUIREMENTS OF ACCESS
CONTROLLED DOORS.
CABLE TRAY, CHANNEL TRAY, BASKET
TRAY
LADDER RACK
WIDTH X HEIGHT
WIDTH X HEIGHT
DIAMETERø C CONDUIT
CONDUIT DOWN
CONDUIT UP
CONDUIT SLEEVE
CONTINUATION
SC-GND-1
SC-ER-1
SC-VWM-1
SC-MPP-1
PA-CPW-1 FIRE RATED PATHWAY
GROUND BAR WALL MOUNTED
EQUIPMENT RACK
VERTICAL WIRE MANGER
PATCH PANEL
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
PLAN OR DETAIL SCALE
DETAIL REFERRED TO BY SECTION CUT
SHEET DETAIL IS LOCATED
ON
NAME
VIEW NAME
1/8" = 1'-0"
M101
SIMSIM
INDICATES SIMILAR DETAIL REFERENCED
IN MULTIPLE LOCATIONS
LEVEL NAME
10'-0" HEIGHT ABOVE
PROJECT 0'-0"
1 INDICATES NOTE USED TO DESCRIBE
ADDITIONAL INFORMATION ABOUT
WORK REQUIRED, SPECIFIC TO THE
SHEET AND/OR DETAIL
VIEW KEY
LINE TYPE AND TAG KEY:
NEW WORK BY THIS CONTRACTOR (WIDE LINE)
NEW
EXISTING TO BE REMOVED (SHORT DASHED PATTERN)
NEW UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)
EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE)
EXISTING
EXISTING TO BE REMOVED BY OTHERS (SHORT DASHED PATTERN)
EXISTING UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)
HALFTONING DOES NOT MODIFY SCOPE.
'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING
TAG-1 UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL
INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST
INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL
T101
SECURITY CONTRACTORS.C.
ASBESTOS ABATEMENT CONTRACTOR
FIRE PROTECTION CONTRACTORF.P.C.
PLUMBING CONTRACTORP.C.
GENERAL CONTRACTORG.C.
MECHANICAL CONTRACTORM.C.
ELECTRICAL CONTRACTORE.C.
A.C.
CONTRACTOR ABBREVIATION KEY
ABBR: DESCRIPTION:
TECHNOLOGY CONTRACTORT.C.
M
A X
20" MAX.
M
A X
20"-25" MAX.
M
A X
M
IN
. 4
M
A X
M
A X
10" MAX. 10"-24" MAX.
ADA GUIDELINES - FRONT ACCESS
ADA STANDARDS FOR ACCESSIBLE DESIGN
INSTALL ABOVE COUNTER
DEVICE AT 44" ABOVE
FINISHED FLOOR.
INSTALL ABOVE COUNTER
DEVICE AT 40" ABOVE
FINISHED FLOOR.
INSTALL DEVICE AT 18"
ABOVE FINISHED FLOOR.
ADA GUIDELINES - SIDE ACCESS
INSTALL DEVICE AT 44"
ABOVE FINISHED FLOOR.
INSTALL DEVICE AT 42"
ABOVE FINISHED FLOOR.
1. THE DRAWINGS INDICATE EXISTING ITEMS TO BE REMOVED. THE DRAWINGS ARE
INTENDED TO INDICATE THE SCOPE OF WORK REQUIRED AND DO NOT INDICATE EVERY
BOX, CONDUIT, OR WIRE THAT MUST BE REMOVED.
2. ITEMS (i.e. SPEAKERS, SWITCHES, ETC.) REMOVED AND NOT RELOCATED REMAIN THE
PROPERTY OF THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
DISPOSAL OF MATERIAL THE OWNER DOES NOT WANT TO REUSE OR RETAIN. (i.e., FOR
MAINTENANCE PURPOSES).
3. EXISTING TO REMAIN DEVICES WITHIN OR ADJACENT TO THE PATH OF CONSTRUCTION
SHALL BE PROTECTED IN PLACE. DEVICES THAT MUST BE REMOVED SHALL BE TESTED
PRIOR TO REMOVAL, PROTECTED FROM DAMAGE, AND RE-INSTALLED IN ITS ORIGINAL
LOCATION DURING THE NEW CONSTRUCTION PHASE OF THE PROJECT.
4. OBTAIN APPROVAL FROM THE OWNER BEFORE TURNING OFF THE POWER TO EQUIPMENT,
SYSTEMS, PANELS, ETC. COORDINATE ALL OUTAGES WITH OWNER. CONDUIT CONCEALED
IN WALL CONSTRUCTION MAY BE ABANDONED IN PLACE IF NOT AFFECTED BY OTHER
CONSTRUCTION.
5. ALL CONDUIT SHALL BE REMOVED WHERE WALLS ARE BEING REMOVED. WHERE CONDUIT
IS IN THE CONCRETE SLAB, CUT OFF FLUSH, PULL OUT WIRE, AND PLUG. WHERE CONDUIT
IS RUN EXPOSED, ALL ASSOCIATED CLAMPS, SUPPORTS, HANGERS, ETC., SHALL ALSO BE
REMOVED.
6. COORDINATE ALL WORK WITH OTHER CONTRACTORS AT THE JOB SITE BEFORE REMOVING
EXISTING EQUIPMENT AND INSTALLING NEW ITEMS.
7. EXISTING CONDUIT IN GOOD CONDITION, MAY BE REUSED IN PLACE. RELOCATING EXISTING
CONDUIT SHALL NOT BE ALLOWED. BONDING CONDUCTORS SHALL BE INSTALLED IN ALL
REUSED CONDUIT TO ASSURE PROPER GROUND PATH.
8. EQUIPMENT REMOVAL IN CERTAIN LOCATIONS MAY REQUIRE THE INSTALLATION OF A
JUNCTION BOX TO RECONNECT CIRCUITS THAT REMAIN IN OPERATION. EXTEND CONDUIT
AND WIRING AS REQUIRED TO MAINTAIN POWER TO REMAINING EQUIPMENT.
9. DEVICES TO BE REMOVED SHALL HAVE ALL CONNECTED WIRING REMOVED TO THE
SOURCE.
10. DEVICES NOT TO BE REMOVED SHALL BE PROTECTED FROM THE ENVIRONMENT, AND ALL
ASSOCIATED CABLE/RACEWAYS ARE TO REMAIN AND BE PROTECTED. T.C. SHALL BE
RESPONSIBLE FOR REPAIR OF ANY INTERRUPTIONS TO PROTECTED DEVICES.
11. REFER TO SPECIFICATIONS SECTION 27 05 00 AND 27 05 05 FOR ADDITIONAL
12. ALL ABANDONED EQUIPMENT IN THE TELECOMMUNICATION ROOMS BEING ABANDONED OR
TURNED OVER TO THE NAVY SHALL BE REMOVED AS PART OF THE CONTRACTORS SCOPE.
THIS INCLUDES BUT NOT LIMITED TO RACKS, CABINETS, PATCH PANEL, VOICE WALLFIELDS
AND BONDING SYSTEMS. COORDINATE WITH OWNER PRIOR TO REMOVAL.
13. CONTRACTOR IS TO REMOVE ALL REPLACED CABLING IN ITS ENTIRETLY TO THE TR. NO
CABLING SHALL BE ABANDONED IN PLACE.
TECHNOLOGY DEMOLITION NOTES
TECHNOLOGY ABBREVIATION KEY
ENTRANCE FACILITYEF-#
MAIN CROSS-CONNECTMC-#
TELECOMMUNICATIONS ROOMTR-#
ABOVE FINISHED FLOORAFF
BELOW FINISHED CEILINGBFC
CONDUITC
SIMILARSIM
TYPICALTYP
MOUNTING HEIGHT ABOVE FINISHED FLOOR+#
JUNCTION BOXJ-BOX
ABBR: DESCRIPTION:
UNLESS OTHERWISE NOTEDUON
FIELD OF VIEWFOV
DOUBLE POLE DOUBLE THROWDPDT
PAN TILT ZOOMPTZ
POWER OVER ETHERNETPOE
ABOVE FINISHED GRADEAFG
DELAYED EGRESSDE
1. ALL CABLING IS TO BE INSTALL PER THE LATEST STANDARDS.
2. ALL TESTING EITHER REQUIRED BY RULE, SPEC OR CODE OR AT THE REQUEST OF THE
COR, ARE SOLELY THE RESPONSIBILITY OF THE CONTRACTOR FOR BOTH TIME AND
DOLLARS.
3. ALL CABLES ARE TO BE END TO END REEL TESTED PRIOR TO UNSPOOLING AND AT
LEAST 10 DAYS PRIOR TO INSTALLATION.
4. PASSING TEST RESULTS FOR EACH REEL, CLEARING IDENTIFYING CABLE TYPE AND
REEL#, TO BE SUBMITTED TO COR NOT LESS THAN 72 HOURS PRIOR TO INSTALLATION
5. INSTALLATION OF CABLE TO BE IN ACCORDANCE WITH SECTION 27 15 00.
6. ALL CABLES, TRAYS, AND CONDUITS ARE TO BE LABELED AT INITIAL INSTALL PER THE
TIA-568-C.1 AND TIA-606 STANDARDS.
7. ALL CABLE TRAYS, CONDUITS AND PATHWAYS INSTALLATIONS SHALL BE PER THE
TIA-569-B STANDARD.
8. ALL INSTALLATIONS ARE TO ADHERE TO THE MANUFACTURES BEND RADIUS
RECOMMENDATIONS. ANY CABLE FOUND TO BE IN A RADIUS TIGHTER THAT
RECOMMENDED WITH BE, AT THE SOLE DISCRETION OF THE COR, EITHER TESTED FOR
FITNESS, FITNESS BEING AS DETERMINED BY THE COR, OR BE REPLACED, IN FULL, AT
THE CONTRACTORS SOLE EXPENSE IN BOTH TIME AND DOLLARS.
9. ANY CABLE FOUND TO SHOW DAMAGE OF ANY KIND SHALL, AT THE SOLE DISCRETION OF
THE COR, BE EITHER, TESTED FOR FITNESS, FITNESS BEING DETERMINED SOLELY BY
THE COR, OR BE REPLACED AT THE CONTRACTORS SOLE EXPENSE IN BOTH TIME AND
DOLLARS.
10. ANY TERMINATION SHOWING SIGNS OF DAMAGE, OF POOR INSTALLATION QUALITY, OR
NOT PASSING TESTING, SHALL BE REPLACED AT THE CONTRACTOR'S SOLE EXPENSE IN
BOTH TIME AND DOLLARS.
11. ALL CABLING IS TO BE INSTALLED IN SUCH A MANOR AS TO HAVE SMOOTH FLOWING
CABLE RUNS WITHOUT CABLES WRAPPING, THRU OR AROUND OTHER CABLES. THIS IS
TO INCLUDE EXISTING CABLES WITHIN A RUN.
12. ALL CABLES UPON ENTERING THE TR OR MC SHALL TAKE A MINIMUM OF ONE RUN, A
MINIMUM OF 20', TO ATTAIN SERVICE LOOP, AROUND THE RACETRACK PRIOR TO
WATERFALLING DOWN TO THE RACK FOR TERMINATION.
13. ALL CABLES SHALL BE LABELED, IN ACCORDANCE WITH THE TIA-606 STANDARD, AT BOTH
TERMINATION POINTS AND PRIOR TO ENTERING OR EXITING A THRUWAY, CABLE WAY, OR
CONDUIT.
14. ONLY RIGID METAL CAN SUPPORT CABLE. USE OF PLASTICS, ZIP TIES OR OTHER
MATERIALS IS NOT PERMITTED TO SUPPORT CABLES.
15. BUNDLING OF CABLES CAN ONLY BE ACCOMPLISHED UTILIZING A VELCRO TYPE CABLE
WRAP. USE OF ZIP TIES TO BUNDLE CABLE IS NOT PERMISSIBLE.
16. CABLES TRANSITIONING INTO OR OUT OF A CABLE TRAY SHOULD CLEANLY TRANSITION
WITHOUT WRAPPING THRU OR AROUND OTHER CABLES.
17. SMALL CABLE COUNTS CANNOT PASS THRU WALLS, FLOORS OR CEILINGS WITHOUT
BEING IN RIGID CONDUIT AND MUST BE FIRE STOPPED ON BOTH SIDES UTILIZING
APPROVED FIRESTOPPING METHODS.
18. J-HOOKS ARE PERMISSIBLE FOR UP TO 6 CIRCUITS.
19. CABLE CANNOT BE UNSUPPORTED FOR DISTANCES GREATER THAN 4'.
20. CABLE CAN ONLY BE SUPPORTED BY COMPONENTS OR SYSTEMS SPECIFICALLY
DESIGNED FOR THAT PURPOSE. UTILIZATION OF PIPING, CONDUIT OR OTHER CABLE IS
NOT PERMISSIBLE.
21. ALL CABLING NO LONGER ACTIVE AFTER A TR CUTOVER SHOULD BE COMPLETELY
DEMOED FROM SOURCE TO POINT OF SERVICE.
GENERAL CABLING NOTES:
1. CUTOVERS SHALL BE PER SINGLE, INDIVIDUAL, TR.
2. WHERE PERMITTED THE CONTRACTOR IS SOLELY RESPONSIBLE FOR PROVIDING ALL
APPROPRIATELY BADGED RESOURCES TO PROVIDE ALL REQUIRED ESCORTS WITHOUT
RELIANCE ON ANY VA OR GOVERNMENT STAFF.
3. EACH CUTOVER SHALL BE SCHEDULED NOT LESS THAN 10 DAYS FROM THE COMPLETED
INSTALL OF THE NETWORK SWITCHES.
4. THE DURATION OF THE CUTOVER SHALL BE COORDINATED WITH THE COR PRIOR TO
SUBMISSION OF THE SCHEDULING REQUEST.
5. A CUTOVER SHALL NOT BE SCHEDULED UNTIL ANY AND ALL DEFICIENCIES FROM EITHER
THE INSPECTIONS, TESTING OR RECORDS ARE MITIGATED AND ACCEPTED BY THE COR IN
WRITING.
6. THE CONTRACTOR SHALL SUBMIT THE REQUEST FOR NETWORK CUTOVER, TO THE COR,
TAKING INTO ACCOUNT THE REQUIREMENT FOR THE PRE-NETWORK SWITCH
INSTALLATION INSPECTION TIMELINES.
7. THE REQUEST FOR CUTOVER SHALL CONTAIN A FULLY DEVELOPED, STEP BY STEP,
TIMELINE PLAN TAKING INTO ACCOUNT ANY AND ALL TASK, COORDINATION, OUTAGES,
LOGISTICAL REQUIREMENTS, AND ANY OTHER REQUIREMENTS NECESSARY FOR A
SUCCESSFUL EVOLUTION, IN TIMELINE, IN AN EDITABLE ELECTRONIC FORMAT, FOR COR
APPROVAL.
8. THE COR SHALL USE BEST EFFORTS TO SCHEDULE THE REQUESTED DATES BUT THE
ULTIMATE TIMELINE SHALL BE BASED UPON THE AVAILABILITY AND LOGISTICS OF ALL
PARTIES.
9. UPON FINAL TERMINATION AND TESTING OF EACH SERVICE PANEL EACH CIRCUIT A
COMPLETE END TO END TEST SHALL BE PERFORMED.
10. UPON THE PASSING TEST THE OWNER SHALL CONNECT EACH CERTIFIED CIRCUIT FROM
THE ASSIGNED PATCH PORT, UTILIZING THE CONTRACTOR PROVIDED 6A PATCH CABLE,
TO THE NETWORK PORT.
11. A FINAL THRU PUT FROM THE DATA CENTER TO THE SERVICE PORT SHOULD BE LOGGED
AND ADDED TO THE RECORD.
12. ANY AND ALL DEFICIENCIES ENCOUNTERED DURING THE CUTOVER ARE TO BE
CORRECTED PRIOR TO THE CONTRACTOR DEMOBILIZING FROM THE CUTOVER
EVOLUTION.
GENERAL CUTOVER NOTES:
1. THE CONTRACTOR IS RESPONSIBLE FOR SCHEDULING, WITH THE COR, A
CONSTRUCTION WALK THRU AT LEAST 10 DAYS PRIOR TO CONSTRUCTION START OF A
TR LOCATION. THE WALKTHROUGH SHOULD HAVE IN ATTENDANCE THE SUPERVISOR
FOR THE GENERAL CONTRACTOR AS WELL AS EACH SUBCONTRACTOR PERFORMING
WORK WITHIN THE TR.
2. THE CONTRACTOR IS RESPONSIBLE FOR SCHEDULING, WITH THE COR, AN INTERIM
INSPECTION OF EACH TR LOCATION NOT LESS THAN 10 DAYS PRIOR TO THE MID POINT
OF COMPLETION FOR THE TR LOCATION. THE PROGRESS AT THIS POINT SHALL BE
UTILIZED TO ADJUST PROJECT SCHEDULE PER SECTION 01 32 16.15.
3. THE CONTRACTOR IS RESPONSIBLE FOR SCHEDULING, WITH THE COR, A PRE-NETWORK
SWITCH INSTALLATION INSPECTION, NOT LESS THAN 10 DAYS PRIOR TO THE SCHEDULED
NETWORK SWITCH INSTALL DATE, AT WHICH TIME ALL SCOPE, EXCEPT FINAL
TERMINATION OF THE SERVICE END AND FINAL CIRCUIT TESTING FROM PATCH THRU
SERVICE RECEPTACLE, SHALL BE COMPLETE.
4. ANY DEFICIENCIES FOUND SHALL BE CORRECTED IN A MANOR AS TO NOT IMPEDE
SCHEDULED EVENTS INCLUDING, BUT NOT LIMIT TO, THE CUTOVER.
5. A FINAL INSPECTION IS TO BE SCHEDULED AFTER A MINIMUM 10 DAYS OF FULL
OPERATIONAL RUN TIME.
6. ANY DEFICIENCIES SHALL BE CORRECTED WITHIN 72 HOURS AND, UPON THE COR'S
SOLE DISCRETION, CAN RESULT IN ADDITIONAL INSPECTIONS UNTIL THE TR MEETS ALL
REQUIREMENTS.
7. A LESSONS LEARNED DOCUMENT, COVERING THE COMPLETE BUILD AND ACCEPTANCE
OF THE INDIVIDUAL TR IS DUE NOT MORE THAN 10 DAYS AFTER FINAL ACCEPTANCE.
GENERAL TR ACCEPTANCE NOTES:
SUGGESTED MATRIX OF RESPONSIBILITY
ITEM: SHOWN ON:
FURNISHED
BY:
INSTALLED
BY: NOTES:
TECHNOLOGY ROUGH-IN, REFER TO
TECHNOLOGY EQUIPMENT SCHEDULE
AND SPECIFICATIONS FOR DEFINITION
T-SERIES E.C. E.C. 3. 4.
INFORMATION OUTLET FACEPLATES,
JACKS, AND TERMINATIONS
T-SERIES T.C. T.C.
CONDUIT SLEEVES (WHEN SHOWN ON
DRAWINGS)
T-SERIES E.C. E.C.
CONDUIT SLEEVES (NOT SHOWN BUT
REQUIRED FOR PROPER INSTALLATION
OF SYSTEM)
N/A T.C. T.C. 2. 4.
TELECOMMUNICATION SYSTEMS
ROUGH-IN
T-SERIES E.C. E.C. 1.
TELECOMMUNICATION EQUIPMENT,
CABLING, AND TERMINATIONS
T-SERIES T.C. T.C.
CABLE TRAY (INCLUDING WIRE BASKET
TRAY) REFER TO SPECIFICATION
SECTION 27 05 28 FOR DEFINITION
T-SERIES E.C. E.C.
LADDER RACK T-SERIES T.C. T.C. 5.
GROUNDING LUGS ON TECHNOLOGY
EQUIPMENT
T-SERIES T.C. E.C. 6.
BONDING SYSTEM FOR TECHNOLOGY
SYSTEM, REFER TO SPECIFICATION
SECTION 27 05 26 FOR DEFINITION
T-SERIES E.C. E.C. 7. 8.
CONNECTION OF TECHNOLOGY
BONDING SYSTEM TO THE ELECTRICAL
GROUND SYSTEM
T-SERIES E.C. E.C.
LINE VOLTAGE POWER (+120V OR
GREATER)
E-SERIES E.C. E.C.
LINE VOLTAGE POWER (NOT SHOWN
BUT REQUIRED FOR PROPER
INSTALLATION OF SYSTEM)
N/A T.C. E.C. 2. 4.
LINE VOLTAGE POWER FOR DOOR
HARDWARE POWER SUPPLIES
ARCH SPEC E.C. E.C.
LOW VOLTAGE CABLING FOR
TECHNOLOGY SYSTEMS
T-SERIES T.C. T.C.
CABLE HANGERS AND SUPPORTS OR
OTHER CABLE ROUTING METHODS
(OTHER THAN CONDUIT AND CABLE
TRAY)
T-SERIES T.C. T.C. 5.
FLOOR BOX (ROUGH-IN) T & E SERIES E.C. E.C.
SUGGESTED MATRIX OF RESPONSIBILITY NOTES
1. LOCATIONS OF TELECOMMUNICATIONS ROUGH-INS SHALL BE INDICATED BY THE INFORMATION
OUTLET SYMBOLS ON THE DRAWINGS. REFER TO THE TECHNOLOGY SYMBOL LIST FOR
ADDITIONAL INFORMATION.
2. BASED ON THE INHERENT DIFFERENCES IN PRODUCTS FROM VARIOUS MANUFACTURERS, ALL
REQUIRED EQUIPMENT MAY NOT BE SHOWN ON THE DRAWINGS FOR ALL ACCEPTABLE
MANUFACTURERS.
3. INCLUDES BACKBOXES AND CONDUIT REQUIRED FOR THE TECHNOLOGY SYSTEMS
INSTALLATION. THE E.C. SHALL BASE THE BID ON THE BASIS OF DESIGN SHOWN ON THE
CONTRACT DOCUMENTS.
4. ALL CHANGES TO THE SLEEVES, BACKBOXES, CONDUITS, AND POWER REQUIRED BECAUSE OF
THE T.C.'S SELECTION OF AN ALTERNATE ACCEPTABLE MANUFACTURER OR FROM SYSTEM
CONFIGURATIONS THAT ARE LEFT TO THE CHOICE OF THE CONTRACTOR SHALL BE INCLUDED
IN THE T.C.'S BID. THIS BID SHALL INCLUDE INSTALLATION BY A LICENSED ELECTRICIAN.
5. UNLESS TRADE RULES DICTATE OTHERWISE.
6. FURNISHED AS PART OF THE EQUIPMENT WHEN POSSIBLE, OR FURNISHED TO THE E.C. FOR
INSTALLATION IN THE FIELD.
7. INCLUDES ALL CONDUCTORS, GROUND BARS, AND TERMINATIONS FOR THE COMPLETE
BONDING SYSTEM REQUIRED BY THE SPECIFICATIONS.
8. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF PANELS AND SWITCHBOARDS SHOWN
IN THE TECHNOLOGY BONDING RISER DIAGRAM AND TYPICAL TELECOM ROOM BONDING FLOW
DIAGRAM.
TELECOM ROOM REFERENCES
TELECOM ROOM
DETAIL / SHEET
REFERENCE
FLOOR PLAN
REFERENCE ARCH ROOM NUMBER
MC-1 B1/1017.TN401 F6/1017.TN102 1012
TR-1 B1/43H.TN401 43H.TN101 G50
TR-2 B1/81H.TN401 81H.TN102 133B
TR-3 B1/152.TN401 152.TN101 101
TR-4 C1/237.TN401 237.TN101A D131
TR-5 D1/237.TN401 237.TN101B M119
TR-6 B1/1007.TN401 1007.TN101 1125
TR-7 E1/1007.TN401 1007.TN102 2163
TR-8 B6/1017.TN401 1017.TN103 2123
TR-9 E1/1017.TN401 1017.TN104 3036
TR-10 B1/1523.TN401 1523.TN101N 1030
TR-11 E1/1523.TN401 1523.TN101S 1064
VCI
Project Management
Construction Management
Engineering Location
Issue Date
Project Number
Building Number
Drawing Number
Project Title
Checked Drawn
Drawing Title
Approved:
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
Project Director
Revisions: Date:
VA FORM 08 - 6231
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
556-21-700
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
CD (100%) SUBMITTAL
B
IM
/2
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M u p g ra d e s /T
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M C
.r v t
/8
/2
:5
:0
P M
TN001
TECHNOLOGY COVERSHEET
ALL
ACA SKM
North Chicago, IL
03/08/2023
TECHNOLOGY SHEET INDEX
TN001 TECHNOLOGY COVERSHEET
43H.TD101 FIRST FLOOR DEMOLITION - TECHNOLOGY - BLDG 43H
43H.TD102 SECOND FLOOR DEMOLITION - TECHNOLOGY - 43H
43H.TN101 FIRST FLOOR - TECHNOLOGY - BLDG 43H
43H.TN102 SECOND FLOOR - TECHNOLOGY - BLDG 43H
43H.TN401 TECHNOLOGY ROOM ENLARGEMENTS - BLDG 43H
81H.TD101 BASEMENT DEMOLITION - TECHNOLOGY - BLDG 81H
81H.TD102 FIRST FLOOR DEMOLITION - TECHNOLOGY - BLDG 81H
81H.TD103 SECOND FLOOR DEMOLITION - TECHNOLOGY - BLDG 81H
81H.TN101 BASEMENT - TECHNOLOGY - BLDG 81H
81H.TN102 FIRST FLOOR - TECHNOLOGY - BLDG 81H
81H.TN103 SECOND FLOOR - TECHNOLOGY -BLDG 81H
81H.TN401 TECHNOLOGY ROOM ENLARGEMENTS - BLDG 81H
152.TD101 FIRST FLOOR DEMOLITION - TECHNOLOGY - BLDG 152
152.TN101 FIRST FLOOR - TECHNOLOGY -BLDG 152
152.TN401 TECHNOLOGY ROOM ENLARGEMENTS - BLDG 152
237.TD101A FIRST FLOOR DEMOLITION - TECHNOLOGY - AREA A - BLDG 237
237.TD101B FIRST FLOOR DEMOLITION - TECHNOLOGY - AREA B - BLDG 237
237.TN101A FIRST FLOOR - TECHNOLOGY - AREA A -BLDG 237
237.TN101B FIRST FLOOR - TECHNOLOGY - AREA B - BLDG 237
237.TN401 TECHNOLOGY ROOM ENLARGEMENTS - BLDG 237
1007.TD101 FIRST FLOOR DEMOLITION - TECHNOLOGY - BLDG 1007
1007.TD102 SECOND FLOOR DEMOLITION - TECHNOLOGY - BLDG 1007
1007.TN101 FIRST FLOOR - TECHNOLOGY - BLDG 1007
1007.TN102 SECOND FLOOR - TECHNOLOGY - BLDG 1007
1007.TN401 TECHNOLOGY ROOM ENLARGEMENTS - BLDG 1007
1017.TD101 BASEMENT DEMOLITION - TECHNOLOGY - BLDG 1017
1017.TD102 FIRST FLOOR DEMOLITION - TECHNOLOGY - BLDG 1017
1017.TD103 SECOND FLOOR DEMOLITION - TECHNOLOGY - BLDG 1017
1017.TD104 THIRD FLOOR DEMOLITION - TECHNOLOGY - BLDG 1017
1017.TN101 BASEMENT - TECHNOLOGY - BLDG 1017
1017.TN102 FIRST FLOOR - TECHNOLOGY - BLDG 1017
1017.TN103 SECOND FLOOR - TECHNOLOGY - BLDG 1017
1017.TN104 THIRD FLOOR - TECHNOLOGY - BLDG 1017
1017.TN401 TECHNOLOGY ROOM ENLARGMENTS - BLDG 1017
1523.TD101N FIRST FLOOR DEMOLITION - TECHNOLOGY - NORTH - BLDG 1523
1523.TD101S FIRST FLOOR DEMOLITION - TECHNOLOGY - SOUTH - BLDG 1523
1523.TN101N FIRST FLOOR - TECHNOLOGY - NORTH - BLDG 1523
1523.TN101S FIRST FLOOR - TECHNOLOGY - SOUTH - BLDG 1523
1523.TN401 TECHNOLOGY ROOM ENLARGEMENTS - BLDG 1523
TN501 TECHNOLOGY DETAILS
TN503 TECHNOLOGY DETAILS
TN601 TECHNOLOGY DIAGRAMS
TN701 TECHNOLOGY SCHEDULES
GRAND TOTAL: 44
COMM
G80
TR
G50
LARGE WAITING
G67
LARGE EXAM
G69
LARGE EXAM
G71
SMALL EXAM
G73
SMALL KENNEL
G75
CORR
G74
STORAGE
G48 LARGE KENNEL
G76
CONFERENCE/ STAFF LOUNGE
G77
COURTYARD
STORAGE
G48A
CORRIDOR
G78
RECEPTION
G68
PHARM
G70
DOCTOR OFFICE
G72
OFFICE
G79
OFFICE
G79A
QUARANTINE
G83
QUARANTINE
G84
DECONTAMINATION
G86
VESTIBULE
G82
CORRIDOR
G81
CORRIDOR
G88
JAN
G85
DRY
STO
G90
FEED COOLER
G90A
CLEANED WASTE HOLDING
G91
FEED PREP
G89
CLEAN STORAGE
G87
RECEIVING/ EXAM/ WASH AREA
G92
CORR
G96
F TLT
G93
F SHOWER
G94
M TLT/ SHOWER
G95
CORR
G65
VEST
G64
TOILET
G63PROCEDURE
G61
STORAGE
G62
SUB-
STERILE
G58
SCRUB
G59
OR
G60X-RAY/ PRE-OP/ POST-OP
G56
CORRIDOR
G51
LAUNDRY/ STORAGE
G52
JAN
G55
DARK ROOM
G57TLT
G53
NECROPSY
G54
GAS MAINFOLD
G97
MED/LAB AIR
G98
STAIR
G64A SMALL WAITING
G66
CORRIDOR
G46
PIT
3D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
D
D
D
4D
D
2D
D
D
3D 2D 1V
D
D
V
D
D
V
2D
D
D
V
D
V
2V2D 2 D
D
V
V
2D
D
D
1D-WAP
1D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
D
EXISTING LOCATION OF VOICE
CABLING (#V) TERMINATIONS
EXISTING LOCATION OF DATA
AND WAP CABLING (#D)
TERMINATIONS
VCI
Project Management
Construction Management
Engineering Location
Issue Date
Project Number
Building Number
Drawing Number
Project Title
Checked Drawn
Drawing Title
Approved:
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
Project Director
Revisions: Date:
VA FORM 08 - 6231
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
556-21-700
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
CD (100%) SUBMITTAL
B
IM
/2
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M u p g ra d e s /T
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M C
.r v t
/8
/2
:5
:3
P M
43H.TD101
FIRST FLOOR DEMOLITION -
TECHNOLOGY - BLDG 43H
43H
ACA SKM
North Chicago, IL
03/08/2023
FULLY SPRINKLERED
1/8" = 1'-0"
FIRST FLOOR DEMOLITION - TECHNOLOGY - BLDG 43H
D1
SCALE: 1/8" = 1' - 0"
8 0 8 16246
N
GENERAL NOTES:
1. REFER TO TN001 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SERVED FROM EXISTING TELECOMMUNICATION
ROOMS (AS INDICATED).
3. ALL EXISTING CABLING SHOWN TO BE DEMO'D
SHALL BE REMOVED FROM END TO END AND
REPLACED WITH NEW DATA CABLES.
4. ALL VOICE (#V) LOCATIONS SHOWN HAVE THE
NUMBER OF CABLES INDICATED TERMINATED AT
THE FACEPLATE, PLUS AN ADDITIONAL
CATEGORY 3 CABLE COILED IN THE CEILING. THE
CONTRACTOR SHALL INCLUDE REMOVAL OF THE
COILED CABLE IN ADDITION TO THE #V LOCATION
NOTED TO BE DEMO'D AT EACH OUTLET
LOCATION IN ITS ENTIRETY TO SOURCE.
5. ALL WAP LOCATIONS SHOWN TO BE DEMO'D
REPRESENT REPLACEMENT OF DATA CABLING
ONLY. THE EXISTING ACCESS POINT DEVICE
SHALL BE PROTECTED IN PLACE WITH DATA
CABLING INSTALLED NEW WITH TERMINATION
WITHIN 5'-0" OF DEVICE. INSTALL PATCH CORD TO
COMPLETE INSTALLATION.
STORAGE
G48A
STAIR
G64A
TOILET
OPEN
OFFICE
OFFICE
OFFICE
MECH
STORAGE
OPEN
SPACE
1D-WAP
1D-WAP
1D-WAP
D
V
2D 1V 3D
2D2V 2D2V 2D2V
2D 1V 2V
VCI
Project Management
Construction Management
Engineering Location
Issue Date
Project Number
Building Number
Drawing Number
Project Title
Checked Drawn
Drawing Title
Approved:
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
Project Director
Revisions: Date:
VA FORM 08 - 6231
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
556-21-700
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
CD (100%) SUBMITTAL
B
IM
/2
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M u p g ra d e s /T
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M C
.r v t
/8
/2
:5
:3
P M
43H.TD102
SECOND FLOOR DEMOLITION -
TECHNOLOGY - 43H
43H
ACA SKM
North Chicago, IL
03/08/2023
FULLY SPRINKLERED
1/8" = 1'-0"
SECOND FLOOR DEMOLITION - TECHNOLOGY - 43H
D1
SCALE: 1/8" = 1' - 0"
8 0 8 16246
N
GENERAL NOTES:
1. REFER TO TN001 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SERVED FROM EXISTING TELECOMMUNICATION
ROOMS (AS INDICATED).
3. ALL EXISTING CABLING SHOWN TO BE DEMO'D
SHALL BE REMOVED FROM END TO END AND
REPLACED WITH NEW DATA CABLES.
4. ALL VOICE (#V) LOCATIONS SHOWN HAVE THE
NUMBER OF CABLES INDICATED TERMINATED AT
THE FACEPLATE, PLUS AN ADDITIONAL
CATEGORY 3 CABLE COILED IN THE CEILING. THE
CONTRACTOR SHALL INCLUDE REMOVAL OF THE
COILED CABLE IN ADDITION TO THE #V LOCATION
NOTED TO BE DEMO'D AT EACH OUTLET
LOCATION IN ITS ENTIRETY TO SOURCE.
5. ALL WAP LOCATIONS SHOWN TO BE DEMO'D
REPRESENT REPLACEMENT OF DATA CABLING
ONLY. THE EXISTING ACCESS POINT DEVICE
SHALL BE PROTECTED IN PLACE WITH DATA
CABLING INSTALLED NEW WITH TERMINATION
G80
TR
LARGE WAITING LARGE EXAM LARGE EXAM
SMALL EXAM
SMALL KENNEL
CORR
STORAGE
LARGE KENNEL
CONFERENCE/ STAFF LOUNGE
COURTYARD
STORAGE
CORRIDOR
RECEPTION PHARM DOCTOR OFFICE OFFICE OFFICE QUARANTINE QUARANTINE
DECONTAMINATION
VESTIBULE
CORRIDOR
CORRIDOR
JAN
DRY
STO FEED COOLER CLEANED WASTE HOLDING
FEED PREP
CLEAN STORAGE
RECEIVING/ EXAM/ WASH AREA
CORR
F TLT
F SHOWER
M TLT/ SHOWER
CORR
VEST
TOILET
PROCEDURE
STORAGE
SUB-
STERILE
SCRUB
OR
X-RAY/ PRE-OP/ POST-OP
CORRIDOR
LAUNDRY/ STORAGE
JAN
DARK ROOM
TLT
NECROPSY
GAS MAINFOLD MED/LAB AIR
STAIR
SMALL WAITING
CORRIDOR
TR
G50
G67 G69 G71
G73
G75 G74
G48
G76
G77
G48A
G78
G68 G70 G72 G79 G79A G83 G84
G86
G82
G81
G88
G85
G90 G90A G91
G89
G87
G92
G96
G93
G94
G95
G65
G64
G63
G61
G62
G58
G59
G60
G56
G51
G52
G55
G57
G53
G54
G97 G98
G64A
G66
G46
G80
M E D
G A S
S H U T
O F F
M E D
G A S
S H U T
O F F
M E D
G A S
S H U T
O F F
M E D
G A S
S H U T
O F F
M E D
G A S
C O N T
P N L
MED
GASCONT
PNL
M E D
G A S
S H U T
O F F
MED
GASCONT
PNL
P R E S S U R E
R E
B U
IL
D
IN
G
S T A T
IO
N
P R E S S U R E
R E
B U
IL
D
IN
G
S T A T
IO
N
PRESSURE
RE-BUILDING
STATION
PIT
P
P
P
P
FEC
N
NO
NO
V V
V
V A A
E
NE
NO
V
V
V
A
3D
D
D
D
3D
D
3D
D
D
3D 3D
D
D
D
D
3D
D
D
D
D
3D 3 D
D
3D
D
D
2D-WAP-NV
2D-WAP-NV
2D-WAP-NV
2D-WAP-NV
2D-WAP-NV
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
3D
3D
D
D
D
3D
D
D 3 D
D 2D-WAP-NV2D-WAP-NV
D
D
43H.TN401
B1
TR-1
43H.TN401
D1
VCI
Project Management
Construction Management
Engineering Location
Issue Date
Project Number
Building Number
Drawing Number
Project Title
Checked Drawn
Drawing Title
Approved:
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
Project Director
Revisions: Date:
VA FORM 08 - 6231
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
556-21-700
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
CD (100%) SUBMITTAL
B
IM
/2
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M u p g ra d e s /T
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M C
.r v t
/8
/2
:5
:4
P M
43H.TN101
FIRST FLOOR - TECHNOLOGY - BLDG
43H
43H
ACA SKM
North Chicago, IL
03/08/2023
FULLY SPRINKLERED
1/8" = 1'-0"
FIRST FLOOR - TECHNOLOGY - BLDG B43H
D1
SCALE: 1/8" = 1' - 0"
8 0 8 16246
N
GENERAL NOTES:
1. REFER TO TN001 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
2. TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
3. REFER TO TN701 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED. COORDINATE
DEMO AND CABLE REPLACEMENT WITH
OWNER. REFER TO THE PHASING NOTES IN
THE COVER SHEET FOR MORE INFORMATION.
5. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
6. ALL CABLES ON THIS FLOOR WILL BE SERVED
FROM THE COMM ROOM G50.
KEYNOTES;
1. PROVIDE 24 STRAND OS2 FIBER OPTIC CABLE FROM
EXISTING COMM CLOSET M105 TO TR-5.
G48A
STAIR
G64A
TOILET
OPEN
OFFICE
OFFICE
OFFICE
MECH
STORAGE
OPEN
SPACE
D
3D 3D 3D
3D 3D 3D
2D-WAP-NV 2D-WAP-NV
3D 3D
3D3D3D
VCI
Project Management
Construction Management
Engineering Location
Issue Date
Project Number
Building Number
Drawing Number
Project Title
Checked Drawn
Drawing Title
Approved:
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
Project Director
Revisions: Date:
VA FORM 08 - 6231
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
556-21-700
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
CD (100%) SUBMITTAL
B
IM
/2
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M u p g ra d e s /T
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M C
.r v t
/8
/2
:5
:4
P M
43H.TN102
SECOND FLOOR - TECHNOLOGY -
BLDG 43H
43H
ACA SKM
North Chicago, IL
03/08/2023
FULLY SPRINKLERED
1/8" = 1'-0"
SECOND FLOOR - TECHNOLOGY - 43H
D1
SCALE: 1/8" = 1' - 0"
8 0 8 16246
N
GENERAL NOTES:
1. REFER TO TN001 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
2. TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
3. REFER TO TN701 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED. COORDINATE
DEMO AND CABLE REPLACEMENT WITH
OWNER. REFER TO THE PHASING NOTES IN
THE COVER SHEET FOR MORE INFORMATION.
5. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
6. ALL CABLES ON THIS FLOOR WILL BE SERVED
FROM THE COMM ROOM G50.
CORR
G50
W
W R I
2D-ACP
2D-CAM-VA
CSS
CORR
G50
3D
43H.TN401
C3
SC-CAB-1
KEY NOTES:
1. TWO COMPARTMENT COLLOCATION CABINET WITH TWO LOCKABLE DOORS. ONE
COMPARTMENT FOR VA, ONE COMPARTMENT FOR NAVY. EACH 3D WORK AREA
OUTLET SHALL HAVE TWO DATA CABLES RAN TO THE NAVY COMPARTMENT AND
ONE RAN TO THE VA COMPARTMENT.
2. PROVIDE MUD RING AT OUTLETS ON WALLS WITH 3/4" BACKBOARD.
3. VERIFY FINAL MOUNTING LOCATION WITH VA IS PRIOR TO ROUGH-IN.
SC-GND-1
SPACE RESERVED FOR
ACCESS CONTROL
42 12
SC-CAB-1
(TYP.)
SC-HWM-1
SC-PDU-H
NETWORK SWITCH
SC-HWM-1
SC-BLK-1
SC-FDC-1
SC-BLK-1
SC-MPP-1
SC-MPP-1
SC-BLK-1
SC-BLK-1
SC-BLK-1
SC-MPP-1
SC-MPP-1
SC-MPP-1
SC-BLK-1
SC-HWM-1
NETWORK SWITCH
SC-HWM-1
NETWORK SWITCH
SC-HWM-1
SC-PDU-H
SC-PDU-H
NETWORK SWITCH
SC-HWM-1
SC-MPP-1
SC-UPS-1
SC-UPS-1 VA RACK
NAVY RACK
KEY NOTES:
1. PROVIDE RACK MOUNTED GROUND BAR SC-GND-2 AT TOP REAR OF RACK.
2. ALL FIBER OPTIC CABLE SHALL BE TERMINATED INTO THE NAVY RACK.
3. ALL UTP CABLING WILL ENTER THE TOP RIGHT SIDE AND ROUTE TO THE BAYS CAT6A
STRAIGHT PATCH PANELS. PATCH CABLES FROM THE LOWER BAYS WILL USE THE
LEFT SIDE VERTICAL CABLE CHANNELS TO ROUTE TO THE TOP BAY.
SC-BLK-1
SC-PDU-H
FRONT
SC-BLK-1
NETWORK SWITCH
NETWORK SWITCH
18"x6"
SC-CT-1
(TYP.)
PW-CPW-1
(TYP.)
VCI
Project Management
Construction Management
Engineering Location
Issue Date
Project Number
Building Number
Drawing Number
Project Title
Checked Drawn
Drawing Title
Approved:
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
Project Director
Revisions: Date:
VA FORM 08 - 6231
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
556-21-700
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
CD (100%) SUBMITTAL
B
IM
/2
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M u p g ra d e s /T
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M C
.r v t
/8
/2
:5
:4
P M
43H.TN401
TECHNOLOGY ROOM
ENLARGEMENTS - BLDG 43H
43H
ACA SKM
North Chicago, IL
03/08/2023
FULLY SPRINKLERED
1/4" = 1'-0"
DATA ROOM ENLARGEMENT TR-1
B1
SCALE: 1/4" = 1' - 0"
4 0 4 8123
1" = 1'-0"
EQUIPMENT RACK ELEVATION TR-1
C3
1/4" = 1'-0"
DATA ROOM PATHWAY TR-1
D1
MECH ROOM
B03
STORAGE
B02
STO
B06
MECH ROOM
B04
STORAGE
B10
STORAGE
B05
STORAGE
B07
STORAGE
B08A
STORAGE
B08B
STORAGE
B08C
STORAGE
B09
VESTIBULE
B08
ELEV
BELEV2
STAIR
BST2
STAIR
BST1
STORAGE
B01
ELEC ROOM
B13
ELECTRICAL ROOM
B14
FREIGHT ELEV
BELEV3
MECHANICAL ROOM
B11 BOILER ROOM
ENTRY
UP
UP
2D
2D
D
D
V
D
V
D
V
D
V
2D
2D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
VCI
Project Management
Construction Management
Engineering Location
Issue Date
Project Number
Building Number
Drawing Number
Project Title
Checked Drawn
Drawing Title
Approved:
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
Project Director
Revisions: Date:
VA FORM 08 - 6231
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
556-21-700
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
CD (100%) SUBMITTAL
B
IM
/2
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M u p g ra d e s /T
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M C
.r v t
/8
/2
:5
:4
P M
81H.TD101
BASEMENT DEMOLITION -
TECHNOLOGY - BLDG 81H
81H
ACA SKM
North Chicago, IL
03/08/2023
FULLY SPRINKLERED
1/8" = 1'-0"
BASEMENT DEMOLITION - TECHNOLOGY - B81H
D3
SCALE: 1/8" = 1' - 0"
8 0 8 16246
N
GENERAL NOTES:
1. REFER TO TN001 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SERVED FROM EXISTING TELECOMMUNICATION
ROOMS (AS INDICATED).
3. ALL EXISTING CABLING SHOWN TO BE DEMO'D
SHALL BE REMOVED FROM END TO END AND
REPLACED WITH NEW DATA CABLES.
4. ALL VOICE (#V) LOCATIONS SHOWN HAVE THE
NUMBER OF CABLES INDICATED TERMINATED AT
THE FACEPLATE, PLUS AN ADDITIONAL
CATEGORY 3 CABLE COILED IN THE CEILING. THE
CONTRACTOR SHALL INCLUDE REMOVAL OF THE
COILED CABLE IN ADDITION TO THE #V LOCATION
NOTED TO BE DEMO'D AT EACH OUTLET
LOCATION IN ITS ENTIRETY TO SOURCE.
5. ALL WAP LOCATIONS SHOWN TO BE DEMO'D
REPRESENT REPLACEMENT OF DATA CABLING
ONLY. THE EXISTING ACCESS POINT DEVICE
SHALL BE PROTECTED IN PLACE WITH DATA
CABLING INSTALLED NEW WITH TERMINATION
133B
STORAGE
133C
COMM
STORAGE AREA
TR
ADMINISTRATIVE SPACE
ENTRY
ADMINISTRATIVE OFFICE
MECH ROOM
REFRIGERATOR
133A
WAREHOUSE
OFFICE
STAIR
1ST4
MECH ROOM
OFFICE
136A
FREIGHT ELEV
1ELEV3
ELEV
1ELEV2
STORAGE
133D
STAIR
1ST3
STORAGE
130A
STORAGE AREA
CORRIDOR
ADMINISTRATIVE OFFICE
COOLER
129A
COOLER
ADMINISTRATIVE OFFICE
ADMINISTRATIVE OFFICE
RECEIVING
LOADING AREA
M/F TLT
125A
SHWR RM
RECEIVING
STAIR
1ST1
CLO
113A
VESTIBULE
ELEVATOR
1ELEV1
OFFICE
CORR
STAIR
1ST2
CORR
VAULT
MAIL RM
LOUNGE
M TLT
JAN
107A
F TLT
104A
FOYER
MECH CLO
OFFICE
OFFICE
ELEC
ROOM
133-A
DN
DN
UP
UP
UP
AED
2D
2D
2D
D
D
D
V
D
V
D
V
D
V
1D 1V
1D1V
1D 1V
2D2V
D
V
D
V
D
V
D
V
D
V
D
V
1D 2V1D 2V
1D1V 1D1V
D
V
2D
D
V
D
V
D
V
1D1V
1D1V
2D
1D 1V 1D 1V
D2 D
D
1D2V 2D 1V
D
V
1D 1V
2D
D
D
V
V
D
V
D
V
D
V
1D1V
1D 1V
D
V
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
REMOVE EXISTING
TELEPHONE PUNCH
BLOCKS
PULL BACK THE EXISTING FIBER
AND RE-ROUTE TO THE NEW
TELECOM ROOM SHOWN ON SHEET
81H.TN101
EXISTING LOCATION DATA CABLING
(#D) TERMINATIONS
EXISTING LOCATION DATA CABLING
(#D) TERMINATIONS
VCI
Project Management
Construction Management
Engineering Location
Issue Date
Project Number
Building Number
Drawing Number
Project Title
Checked Drawn
Drawing Title
Approved:
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
Project Director
Revisions: Date:
VA FORM 08 - 6231
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
556-21-700
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
CD (100%) SUBMITTAL
B
IM
/2
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M u p g ra d e s /T
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M C
.r v t
/8
/2
:5
:4
P M
81H.TD102
FIRST FLOOR DEMOLITION -
TECHNOLOGY - BLDG 81H
81H
ACA SKM
North Chicago, IL
03/08/2023
FULLY SPRINKLERED
1/8" = 1'-0"
FIRST FLOOR DEMOLITION - TECHNOLOGY - B81H
F3
SCALE: 1/8" = 1' - 0"
8 0 8 16246
N
GENERAL NOTES:
1. REFER TO TN001 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SERVED FROM EXISTING TELECOMMUNICATION
ROOMS (AS INDICATED).
3. ALL EXISTING CABLING SHOWN TO BE DEMO'D
SHALL BE REMOVED FROM END TO END AND
REPLACED WITH NEW DATA CABLES.
4. ALL VOICE (#V) LOCATIONS SHOWN HAVE THE
NUMBER OF CABLES INDICATED TERMINATED AT
THE FACEPLATE, PLUS AN ADDITIONAL
CATEGORY 3 CABLE COILED IN THE CEILING. THE
CONTRACTOR SHALL INCLUDE REMOVAL OF THE
COILED CABLE IN ADDITION TO THE #V LOCATION
NOTED TO BE DEMO'D AT EACH OUTLET
LOCATION IN ITS ENTIRETY TO SOURCE.
5. ALL WAP LOCATIONS SHOWN TO BE DEMO'D
REPRESENT REPLACEMENT OF DATA CABLING
ONLY. THE EXISTING ACCESS POINT DEVICE
SHALL BE PROTECTED IN PLACE WITH DATA
CABLING INSTALLED NEW WITH TERMINATION
WAREHOUSE
LABORATORY
203A
ADMINISTRATIVE OFFICE
STORAGE
VESTIBULE
STAIRS
2ST1
STORAGE
ADMINISTRATIVE OFFICE
WAREHOUSE
OFFICE
202B
OFFICE
202A
MECH ROOM
ELEV
2ELEV1 STAIRS
2ST2
STORAGE
MEN
WOMEN
HALL
HALL
OFFICE
CONF
OFFICE
OFFICE
OFFICE
OFFICE
OPEN
OFFICE
COPY
BREAK
DN
DN
1D-WAP
1D-WAP
1D-WAP
1D 1D
1D-WAP
1D-WAP
2D
1D-WAP
2D
1D-WAP
1D-WAP
D
D
D
D
D
2D
D
D
D2D 2D
D 2
D D
2D 2D
D
D
D
D
D
D
2D
D
D
D
D
D
D
2D 2D
4D
4D
1D-WAP
1D
D
D
-W A
P
D
V
1D1V
1D 1V1D 1V
1D1V
D
V
1D 1V 1D 1V 1D 1V
1D1V 1D1V
D
V
D
V
D
V
D
V
D
V
D
V
D
V
1D1V
D
2D D
1D-WAP 1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D
2D
VCI
Project Management
Construction Management
Engineering Location
Issue Date
Project Number
Building Number
Drawing Number
Project Title
Checked Drawn
Drawing Title
Approved:
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
Project Director
Revisions: Date:
VA FORM 08 - 6231
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
556-21-700
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
CD (100%) SUBMITTAL
B
IM
/2
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M u p g ra d e s /T
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M C
.r v t
/8
/2
:5
:4
P M
81H.TD103
SECOND FLOOR DEMOLITION -
TECHNOLOGY - BLDG 81H
81H
ACA SKM
North Chicago, IL
03/08/2023
FULLY SPRINKLERED
1/8" = 1'-0"
SECOND FLOOR DEMOLITION - TECHNOLOGY - B81H
F3
SCALE: 1/8" = 1' - 0"
8 0 8 16246
N
GENERAL NOTES:
1. REFER TO TN001 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY SYMBOL LIST.
2. ALL INFORMATION OUTLETS ON THIS SHEET
SERVED FROM EXISTING TELECOMMUNICATION
ROOMS (AS INDICATED).
3. ALL EXISTING CABLING SHOWN TO BE DEMO'D
SHALL BE REMOVED FROM END TO END AND
REPLACED WITH NEW DATA CABLES.
4. ALL VOICE (#V) LOCATIONS SHOWN HAVE THE
NUMBER OF CABLES INDICATED TERMINATED AT
THE FACEPLATE, PLUS AN ADDITIONAL
CATEGORY 3 CABLE COILED IN THE CEILING. THE
CONTRACTOR SHALL INCLUDE REMOVAL OF THE
COILED CABLE IN ADDITION TO THE #V LOCATION
NOTED TO BE DEMO'D AT EACH OUTLET
LOCATION IN ITS ENTIRETY TO SOURCE.
5. ALL WAP LOCATIONS SHOWN TO BE DEMO'D
REPRESENT REPLACEMENT OF DATA CABLING
ONLY. THE EXISTING ACCESS POINT DEVICE
SHALL BE PROTECTED IN PLACE WITH DATA
CABLING INSTALLED NEW WITH TERMINATION
MECH ROOM
B03
STORAGE
B02
STO
B06
MECH ROOM
B04
STORAGE
B10
STORAGE
B05
STORAGE
B07
STORAGE
B08A
STORAGE
B08B
STORAGE
B08C
STORAGE
B09
VESTIBULE
B08
ELEV
BELEV2
STAIR
BST2
STAIR
BST1
STORAGE
B01
ELEC ROOM
B13
ELECTRICAL ROOM
B14
FREIGHT ELEV
BELEV3
MECHANICAL ROOM
B11 BOILER ROOM
ENTRY
UP
UP
UNEXCAVATED
SPACE
3D
3D
D
D
D 3
D D
3D
3D
2D-WAP-NV
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-NV
D
D
D
3D
D
-A C
P
2D-WAP-NV
2D-WAP-NV
2D-WAP-NV
2D-WAP-NV
2D-WAP-NV
2D-CAM-VA
VCI
Project Management
Construction Management
Engineering Location
Issue Date
Project Number
Building Number
Drawing Number
Project Title
Checked Drawn
Drawing Title
Approved:
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
Project Director
Revisions: Date:
VA FORM 08 - 6231
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
556-21-700
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
CD (100%) SUBMITTAL
B
IM
/2
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M u p g ra d e s /T
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M C
.r v t
/8
/2
:5
:4
P M
81H.TN101
BASEMENT - TECHNOLOGY - BLDG
81H
81H
ACA SKM
North Chicago, IL
03/08/2023
FULLY SPRINKLERED
SCALE: 1/8" = 1' - 0"
8 0 8 16246
N
1/8" = 1'-0"
BASEMENT - TECHNOLOGY - BLDG B81H
D3
GENERAL NOTES:
1. REFER TO TN001 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
2. TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
3. REFER TO TN701 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED. COORDINATE
DEMO AND CABLE REPLACEMENT WITH
OWNER. REFER TO THE PHASING NOTES IN
THE COVER SHEET FOR MORE INFORMATION.
5. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
6. ALL CABLES ON THIS FLOOR WILL BE SERVED
FROM THE NEW TELECOM ROOM. REFER TO
SHEET 81H.TN101 FOR LOCATION.
133-B
STORAGE AREA
TR
ADMINISTRATIVE SPACE
ENTRY
ADMINISTRATIVE OFFICE
MECH ROOM
REFRIGERATOR
WAREHOUSE
OFFICE
STAIR
MECH ROOM
OFFICE
FREIGHT ELEV
ELEV
STORAGESTAIR
STORAGE
STORAGE AREA
CORRIDOR
ADMINISTRATIVE OFFICE
COOLER
COOLER
ADMINISTRATIVE OFFICE
ADMINISTRATIVE OFFICE
RECEIVING
LOADING AREA
M/F TLT SHWR RM
RECEIVING
STAIRCLO
VESTIBULE
ELEVATOR
OFFICE
CORR
STAIR
CORR
VAULT
MAIL RM
LOUNGE
M TLTJAN F TLT
FOYER
MECH CLO
OFFICE
OFFICE
ELEC
ROOM
133A
1ST4
136A
1ELEV3
1ELEV2
133D1ST3
130A
129A
125A 125
1ST1113A
1ELEV1
1ST2
105107A 104A
133-A
DN
DN
UP
UP
UP
LOADING
DOCK
LOADING
DOCK
AED
3D
3D
3D
D
3D 3D
D
D
D
D
D
D
D
D
D
D
D
3D
D
D
3D
3D3D
3D 3D
3D
3D
3D
D
3D
3D
D
D
D
3D
3D
D
D
D
2D-WAP-NV
2D-WAP-VA
2D-WAP-NV
2D-WAP-NV
2D-WAP-NV
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
D
D
D
W
2D-WAP-NV
2D-WAP-NV
2D-WAP-NV
2D-WAP-NV
2D-WAP-NV
2D-WAP-NV
81H.TN401
B1
TR-2
81H.TN401
D1
SC-MPP-24
SC-MPP-24
VCI
Project Management
Construction Management
Engineering Location
Issue Date
Project Number
Building Number
Drawing Number
Project Title
Checked Drawn
Drawing Title
Approved:
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
Project Director
Revisions: Date:
VA FORM 08 - 6231
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
556-21-700
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
CD (100%) SUBMITTAL
B
IM
/2
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M u p g ra d e s /T
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M C
.r v t
/8
/2
:5
:4
P M
81H.TN102
FIRST FLOOR - TECHNOLOGY - BLDG
81H
81H
ACA SKM
North Chicago, IL
03/08/2023
FULLY SPRINKLERED
1/8" = 1'-0"
FIRST FLOOR - TECHNOLOGY - B81H
F3
SCALE: 1/8" = 1' - 0"
8 0 8 16246
N
KEYNOTES;
1. THE NEW TELECOM ROOM BACKBONE SHALL BE
SERVED WITH THE EXISTING FIBER PULLED BACK
FROM THE EXISTING CLOSET. REFER TO SHEET
81H.TD101 FOR EXISTING LOCATION.
2. INSTALL (24) CATEGORY 6A CABLE TO NAVY RACK.
GENERAL NOTES:
1. REFER TO TN001 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
2. TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
3. REFER TO TN701 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED. COORDINATE
DEMO AND CABLE REPLACEMENT WITH
OWNER. REFER TO THE PHASING NOTES IN
THE COVER SHEET FOR MORE INFORMATION.
5. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
FROM THE NEW TELECOM ROOM.
WAREHOUSE
LABORATORY
203A
ADMINISTRATIVE OFFICE
STORAGE
VESTIBULE
STAIRS
2ST1
STORAGE
ADMINISTRATIVE OFFICE
WAREHOUSE
OFFICE
202B
OFFICE
202A
MECH ROOM
ELEV
2ELEV1 STAIRS
2ST2
STORAGE
MEN
WOMEN
HALL
HALL
OFFICE
CONF
OFFICE
OFFICE
OFFICE
OFFICE
OPEN
OFFICE
COPY
BREAK
DN
DN
P
P
3D
2D-WAP-NV
2D-WAP-NV
2D-WAP-NV
3D 3D
2D-WAP-NV
2D-WAP-NV
3D
2D-WAP-NV
3D
2D-WAP-NV
2D-WAP-NV
D
D
D
3D
D
D
3D
D
3D
D
D
3D 3D
3D
3D
2D-WAP-NV
3D
D
D
3D
3D3D
3D
D3D 3D 3D
3D 3D
D
D
D
D
D
D
D
3D
D
3D D
2D-WAP-VA 2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-VA
2D-WAP-NV
VCI
Project Management
Construction Management
Engineering Location
Issue Date
Project Number
Building Number
Drawing Number
Project Title
Checked Drawn
Drawing Title
Approved:
VETERANS
HEALTH
ADMINISTRATION
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT EHRM INFRASTRUCTURE UPGRADES
CAPTAIN JAMES A. LOVELL FHCC
EAST CAMPUS - NORTH CHICAGO
Project Director
Revisions: Date:
VA FORM 08 - 6231
A
CD (100%) SUBMITTAL
(ISSUED FOR BID AND
CONSTRUCTION)
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
57 LOUIS PRIMA DR., SUITE B, COVINGTON, LA 70433
504.676.8337; John Vollman
556-21-700
Name: David Simon Department of Veterans Affairs
Phone: 224.610.3561 Email: david.simon@va.gov
CD (100%) SUBMITTAL
B
IM
/2
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M u p g ra d e s /T
.0
V A
-N o rt h
C h ic a g o
IL
-E
H R
M C
.r v t
/8
/2
:5
:4
P M
81H.TN103
SECOND FLOOR - TECHNOLOGY
-BLDG 81H
81H
ACA SKM
North Chicago, IL
03/08/2023
FULLY SPRINKLERED
1/8" = 1'-0"
SECOND FLOOR - TECHNOLOGY - B81H
F3
SCALE: 1/8" = 1' - 0"
8 0 8 16246
N
GENERAL NOTES:
1. REFER TO TN001 TECHNOLOGY COVERSHEET
FOR TECHNOLOGY GENERAL NOTES,
2. TECHNOLOGY INSTALLATION NOTES AND
SYMBOL LIST.
3. REFER TO TN701 FOR GENERAL TECHNOLOGY
EQUIPMENT SCHEDULE.
4. ALL INFORMATION OUTLETS ON THIS SHEET
TO BE CABLED ON A SCHEDULED BASIS WITH
OWNER WHILE OCCUPIED. COORDINATE
DEMO AND CABLE REPLACEMENT WITH
OWNER. REFER TO THE PHASING NOTES IN
THE COVER SHEET FOR MORE INFORMATION.
5. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
6. ALL CABLES ON THIS FLOOR WILL BE SERVED
FROM THE NEW TELECOM ROOM. REFER TO
SHEET 81H.TN101 FOR LOCATION.
133-B
W
CSS
W R I
D
-A C
P2D-CAM-VA
TR
81H.TN401
C3
SC-ER-1
SC-VWM-1
(TYP.)
(TYP.)
SC-TTB
(TYP.)
SC-GND-1
KEY…