These are architectural and engineering design drawings for the renovation of Room P111 in Building 1 at the U.S. National Poultry Research Center in Athens, Georgia. The comprehensive set of 25 technical drawings covers multiple disciplines including architectural plans, demolition plans, mechanical systems, electrical systems, plumbing, fire alarm, and telecommunications infrastructure.
Key renovation scope includes replacing electrical panels, installing new lighting and power systems, renovating HVAC equipment, updating plumbing fixtures, adding a new service sink, replacing an existing water source heat pump, and upgrading telecommunications infrastructure. The project involves selective demolition of existing systems, with careful preservation of some existing equipment like freezers. The drawings are dated for a December 2024 implementation, with a 100% design submittal and detailed specifications for contractor execution, focusing on modernizing and upgrading the research facility's room P111 infrastructure.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING 1, NATIONAL POULTRY RESEARCH CENTER
RENOVATE ROOM P111
ATHENS, GEORGIA
U.S. DEPARTMENT OF AGRICULTURE
AGRICULTURAL RESEARCH SERVICE
A/E DESIGN CONTRACT #12405B21D0003
A/E DESIGN TASK ORDER #12805B24F0352
NO SCALEVICINITY MAP
DRAWING NO.SHEET NO. TITLE
T-101
HM101
AD101
A-001 A-101 A-201 P-101 P-601
MD101
M-101 M-501 M-502 M-601 M-701 E-001 E-002
ED101
E-101 E-201 E-202 E-301 E-601 F-101 T-101 T-102
1 OF ?
2 OF ?
3 OF ?
4 OF ?
5 OF ?
6 OF ?
7 OF ?
8 OF ?
9 OF ?
10 OF ?
11 OF ?
12 OF ?
13 OF ?
14 OF ?
15 OF ?
16 OF ?
17 OF ?
18 OF ?
19 OF ?
20 OF ?
21 OF ?
22 OF ?
23 OF ?
24 OF ?
25 OF ?
TITLE SHEET
PARTIAL FIRST FLOOR PLAN - HAZARDOUS MATERIAL
PARTIAL FIRST FLOOR PLANS - DEMOLITION
ARCHITECTURAL NOTES AND LEGEND
PARTIAL FIRST FLOOR PLANS
SCHEDULES AND DETAILS
PARTIAL FIRST FLOOR PLUMBING PLAN
PLUMBING SCHEDULE AND DETAILS
PARTIAL FIRST FLOOR HVAC DEMOLITION PLAN
PARTIAL FIRST FLOOR HVAC PLAN
MECHANICAL DETAILS
MECHANICAL DETAILS
MECHANICAL SCHEDULES AND DETAILS
MECHANICAL CONTROLS
ELECTRICAL NOTES
ELECTRICAL LEGEND
ELECTRICAL DEMOLITION
POWER PLAN
LIGHTING PLAN
LIGHTING DETAILS
EQUIPMENT PLAN
POWER SCHEDULES AND RISER
FIRE ALARM PLAN
TELECOMMUNICATIONS PLAN
TELECOMMUNICATION FIBER PLAN
INDEX OF DRAWINGS NO SCALELOCATION MAP
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
TITLE SHEET
T-101
1 XX4/22/2025
RPP
RPP
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
ATLANTA
PROJECT LOCATION,
ATHENS, GEORGIA
AUGUSTA
MACON
DALTON
NATIONAL POULTRY RESEARCH CENTER
950 COLLEGE STATION ROAD
ATHENS, GA 30605
PROJECT LOCATION
COLLEGE STATION ROAD
STATE OF GEORGIA
100% DESIGN SUBMITTAL
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
Z:\
Jo bs \61
-A
US
DA
B1 Re no va te P1
La b - At he ns
G A\0
7 W ork ing Fo lde r\A rch
\HM
1.d wg Ap r 2 3,
- 3 :18 pm c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
PARTIAL FIRST FLOOR PLAN
HAZARDOUS MATERIALS
HM101
1 XX12/10/2024
RPP
RPP
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
P128
CHASE
P122
STORAGE
P125
JANITOR
PP-5
STAIR
P120
STORAGE
P119
FREEZER
P118
FREEZER
P117
FREEZER
P116
FREEZER
P115
FREEZER
P114
FREEZER
P113
FREEZER
P112
STORAGE
P101
CORRIDOR
P109
WOMEN
P110
MEN
P111
STORAGE
P121
LAB
ELEVATOR
ENVIRONMENTAL NOTES
AD101
1 PARTIAL FIRST FLOOR PLAN - HAZARDOUS MATERIALS
SCALE: 1/4"= 1'-0"
BUILDING 1 - KEY PLAN
AREA OF
WORK
1. THE CONTRACTOR MUST REMOVE AND DISPOSE OF ALL ASBESTOS CONTAINING BUILDING MATERIALS (ACBM) AS HAZARDOUS ASBESTOS WASTE IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL
REGULATIONS.
2. THE CONTRACTOR MUST NOTIFY THE GEORGIA STATE DEPARTMENT OF HEALTH AND ENVIRONMENT A
MINIMUM OF 10 DAYS PRIOR TO ANY DEMOLITION WORK AT THE FACILITY.
3. ALL MECHANICAL AND PLUMBING PIPE JOINT INSULATION IS CONSIDERED AS ASBESTOS CONTAINING MATERIALS. THESE MATERIALS MUST BE REMOVED AND DISPOSED OF AS HAZARDOUS WASTE AND NEW, NON-ASBESTOS PIPE JOINT INSULATION MUST BE PROVIDED TO REPLACE THAT REMOVED. SEE
SPECIFICATION 02 82 00, 'ASBESTOS REMEDIATION' AND THE ASBESTOS SURVEY REPORT BY TERRACON
DATED JANUARY 20, 2025 FOR ADDITIONAL INFORMATION.
4. BUILDING 1 WILL BE OCCUPIED DURING CONSTRUCTION. PROVIDE PROPER CONTAINMENT AND
VENTILATION DURING HAZARDOUS MATERIAL ABATEMENT PROCEDURES AS DIRECTED BY
SPECIFICATIONS.
5. CONTRACTOR IS REQUIRED TO HIRE A STATE OF GEORGIA LICENSED ASBESTOS PROJECT DESIGNER AS
REQUIRED IN SPECIFICATIONS.
LEGEND
HAZARDOUS MATERIAL ABATEMENT AREAS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
Z:\
Jo bs \61
-A
US
DA
B1 Re no va te P1
La b - At he ns
G A\0
7 W ork ing Fo lde r\A rch
\AD
1.d wg Ap r 2 3,
- 3 :18 pm c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
PARTIAL FIRST FLOOR PLANS
DEMOLITION
AD101
1 XX12/10/2024
RPP
RPP
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
P128
CHASE
P122
STORAGE
P125
JANITOR
PP-5
STAIR
P120
STORAGE
P119
FREEZER
P118
FREEZER
P117
FREEZER
P116
FREEZER
P115
FREEZER
P114
FREEZER
P113
FREEZER
P112
STORAGE
P101
CORRIDOR
P109
WOMEN
P110
MEN
P111
STORAGE
P121
LAB
ELEVATOR
4'-0"±
9' -0
GENERAL NOTES
1. ITEMS DENOTED BY DASHED LINES MUST BE DEMOLISHED.
2. EXISTING OVERALL DIMENSIONS ARE PROVIDED FOR GENERAL BIDDING
PURPOSES ONLY.
3. PERFORM ALL HAZARDOUS WASTE ABATEMENT PRIOR TO PERFORMING ANY
OTHER WORK UNDER THIS CONTRACT.
KEYED DEMOLITION NOTES
1. REMOVE EXISTING HVAC EQUIPMENT (SEE MECH.)
2. REMOVE EXISTING ELECTRICAL DEVICES (SEE ELEC.)
3. REMOVE EXISTING 6' HIGH CHAIN LINK FENCING. APPROXIMATELY 41'-6".
4. REMOVE EXISTING 4' CHAIN LINK GATE, RETAIN FOR REINSTALLATION.
5. SAWCUT AND REMOVE EXISTING 6" WIDE CONCRETE CURB , EPOXY
GROUT TO MATCH ADJACENT FINISH FLOOR ELEVATION AS REQUIRED.
6. REMOVE FENCE AS REQUIRED TO REINSTALL EXISTING 4' GATE.
7. REMOVE QUARRY TILE FLOOR AND SETTING BED IN AREA OF NEW WORK.
8. REMOVE HVAC DUCTWORK AND EQUIPMENT, (SEE MECH.)
9. REMOVE LIGHT FIXTURES (SEE ELEC.)
10. SAWCUT AND REMOVE WALL AS REQUIRED FOR NEW DOOR OPENING
11. EXISTING FREEZERS TO REMAIN, PROTECT DURING CONSTRUCTION.
AD101
1 BUILDING 1 PARTIAL DEMOLITION FLOOR PLAN
SCALE: 1/8"= 1'-0"
P128
CHASE
P122
STORAGE
P125
JANITOR
PP-5
STAIR
P120
STORAGE
P119
FREEZER
P118
FREEZER
P117
FREEZER
P116
FREEZER
P115
FREEZER
P114
FREEZER
P113
FREEZER
P112
STORAGE
P101
CORRIDOR
P109
WOMEN
P110
MEN
P111
STORAGE
P121
LAB
ELEVATOR
AD101
2 BUILDING 1 PARTIAL DEMOLITION REFLECTED CEILING PLAN
SCALE: 1/8"= 1'-0"
BUILDING 1 - KEY PLAN
AREA OF
WORK
LEGEND
REMOVE FENCE
FENCE TO REMAIN
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
'-0
'-7
'-2
41'-6" ±
14'-4"± 5'-6" ±
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
Z:\
Jo bs \61
-A
US
DA
B1 Re no va te P1
La b - At he ns
G A\0
7 W ork ing Fo lde r\A rch \A-
1.d wg Ap r 2 3,
- 3 :18 pm c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
ARCHITECTURAL NOTES & LEGEND
A-001
1 XX12/10/2024
RPP
RPP
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
DEMOLITION NOTES
1. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS
PRIOR TO PERFORMING WORK OR FABRICATION OR PURCHASE
OF EQUIPMENT, MATERIALS, AND ASSEMBLIES, BRING ANY
DISCREPANCIES TO THE ATTENTION OF THE CONTRACTING
OFFICER FOR FINAL DETERMINATION.
2. CONTRACTOR MUST PROVIDE TEMPORARY STRUCTURAL
SUPPORT FOR EXISTING CONSTRUCTION DURING THE PROJECT
(AS REQUIRED).
3. CONTRACTOR TO ENSURE THE MEANS OF EGRESS REMAIN
CLEAR OF DEBRIS THROUGHOUT ENTIRETY OF PROJECT
SCOPE.
4. THE DEMOLITION PLANS APPROXIMATE THE EXTENT OF
DEMOLITION. CONTRACTOR REQUIRED TO PROVIDE
DEMOLITION AND REMOVE ALL MATERIALS AS REQUIRED TO
PROVIDE NEW WORK. ANY DISCREPANCY TO BE VERIFIED WITH
THE CONTRACTING OFFICER PRIOR TO COMMENCEMENT IN
WRITING.
5. ALL DEMOLITION DEBRIS MUST BE REMOVED FROM THE PROJECT
LIMITS AND DISPOSED OF IN A MANNER AS REQUIRED BY LAW AND
LOCAL REGULATIONS. THE CONTRACTOR WILL BE RESPONSIBLE
FOR ALL DISPOSAL PERMITS AND REGULATIONS REQUIREMENTS.
WASTE DISPOSAL IS THE RESPONSIBILITY OF THE CONTRACTOR
BUT AT ANY TIME DURING OR AFTER THE PERFORMANCE OF THIS
CONTRACT, IT IS DETERMINED BY THE CONTRACTING OFFICER OR
THEIR AUTHORIZED REPRESENTATIVE THAT THE CONTRACTOR
HAS NOT COMPLIED WITH THE REQUIREMENTS OF THE CONTRACT
THE CONTRACTOR WILL BE REQUIRED TO TAKE ANY CORRECTIVE
ACTION DIRECTED BY THE CONTRACTING OFFICER OR OTHER
COMPETENT AUTHORITY AT NO ADDITIONAL COST TO THE
GOVERNMENT. ANY FINE, FEE, OR PENALTY ASSESSED BY THE
REGULATING AUTHORITY AS A RESULT OF THE CONTRACTOR'S
FAILURE TO COMPLY WITH THIS PROVISION MUST BE PAID BY THE
CONTRACTOR.
6. THE CONTRACTOR MUST CONTROL THE SPREAD OF DUST AND
DEBRIS OUTSIDE OF THE WORK AREAS.
7. THE CONTRACTOR MUST PROVIDE CLEAN, STRAIGHT, NEAT CUTS
FOR DEMOLITION THAT MINIMIZE IMPACTS AND ADVERSE AFFECTS
ON EXISTING FINISHES. COORDINATE THE LOCATION OF THE CUTS
TO ACCOMMODATE FINAL FINISHES.
8. THE PROJECT IS DESIGNED TO BE VIABLE IN ITS FULLY
CONSTRUCTED, FINAL CONFIGURATION. IT IS THE CONTRACTORS
RESPONSIBILITY TO ENSURE THE SAFETY AND STABILITY OF ALL
COMPONENTS DURING CONSTRUCTION.
GENERAL NOTES: ARCHITECTURAL
1. REVIEW ALL PROJECT DOCUMENTS PRIOR TO STARTING
CONSTRUCTION. REPORT ANY DISCREPANCIES TO CONTRACTING
OFFICER PRIOR TO PROCEEDING WITH WORK. DIMENSIONS AND
CONDITIONS RELATING TO EXISTING CONSTRUCTION ARE TO BE
FIELD VERIFIED. THE CONTRACTOR MUST IMMEDIATELY
COMMUNICATE, IN WRITING TO THE CONTRACTING OFFICER,
CONCERNS WHERE THEY BELIEVE DESIGN DOCUMENTS ARE
INSUFFICIENT, INADEQUATE, OR INCORRECT FOR PERFORMING
THE CONSTRUCTION WORK.
2. THE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE
DRAWINGS ARE NOT INTENDED TO INDICATE OR DESCRIBE ALL
WORK REQUIRED FOR THE FULL PERFORMANCE AND
COMPLETION OF THE REQUIREMENTS OF THE CONTRACT
DOCUMENTS.
3. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE
PORTION OF THE CONTRACT DOCUMENTS MUST NOT BE
CONSTRUED TO EXCLUDE OTHER ITEMS NECESSARY OR
IMPLIED THEREFROM.
4. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION
OF ALL PARTS OF THE WORK SO THAT NO WORK MAY BE LEFT
IN AN UNFINISHED OR INCOMPLETE CONDITION.
5. ALL WORK MUST CONFORM TO APPLICABLE INDUSTRY AND
MANUFACTURER'S PUBLISHED STANDARDS FOR QUALITY OF
MATERIALS AND WORKMANSHIP, AS WELL AS, ALL
REQUIREMENTS IN THESE DRAWINGS AND SPECIFICATIONS.
ANY CONFLICTING REQUIREMENTS OF THE SOURCES LISTED
ABOVE MUST BE BROUGHT TO THE CONTRACTING OFFICER'S
ATTENTION PRIOR TO PROCEEDING WITH THE WORK.
6. THE CONTRACTOR MUST PROTECT ANY EXISTING, IN-PLACE,
AND NEW WORK.
7. ALL WORK NOTED "N.I.C." IS NOT MEANT TO BE PART OF THE
CONSTRUCTION SCOPE OF WORK AGREEMENT.
8. THE CONTRACTOR MUST PAY FOR AND COORDINATE THE
REMOVAL AND LEGAL DISPOSAL OF MATERIALS AND RUBBISH.
9. ONCE ON SITE, THE CONTRACTOR MUST VERIFY ALL
DIMENSIONS AND MUST VERIFY ALL NEW AND EXISTING
CONDITIONS, SHOWN ON THESE DRAWINGS. THE CONTRACTOR
MUST NOTIFY THE CONTRACTING OFFICER IN WRITING OF ANY
DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.
10. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN, LARGE
SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. THE
CONTRACTOR MUST NOTIFY THE CONTRACTING OFFICER IN
WRITING OF ANY DIFFERING CONDITIONS BEFORE
COMMENCEMENT OF WORK.
11. NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION,
AND ALTERATION OPERATIONS MUST BE APPLIED.
12. WALL AND/OR CEILING ASSEMBLIES THAT ARE IDENTIFIED WITH
A FIRE RESISTIVE RATING MUST BE CONSTRUCTED AS
DETAILED HEREIN.
13. DIMENSIONS SHOWN ARE TO FACE OF STUD AND FACE OF CMU
(U.N.O.).
14. PROVIDE EXPANSION AND CONTROL JOINTS IN ALL WORK AS
PER PRODUCT MANUFACTURER'S STANDARDS.
15. THE CONTRACTOR MUST PERFORM ALL WORK IN ACCORDANCE
WITH ALL APPLICABLE CODES, ORDINANCES AND REGULATORY
AGENCIES AND MUST OBTAIN NECESSARY BUILDING AND FIRE
PERMITS FROM ALL AUTHORITIES HAVING JURISDICTION.
16. ALL INTERIOR FINISH MATERIALS MUST COMPLY WITH THE
REQUIREMENTS OF ALL APPLICABLE CODES, ORDINANCES AND
REGULATORY AGENCIES.
17. ALL DISSIMILAR METALS MUST BE ISOLATED FROM EACH OTHER
AND CEMENTITIOUS SURFACES TO AVOID GALVANIC
CORROSION.
18. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS
AND MATERIALS. SHEETS ARE TO BE REVIEWED AND NOTES ON
INDIVIDUAL SHEETS MUST BE APPLIED TO RELATED DRAWINGS
AND DETAILS.
19. A FINISH INDICATION ON A WALL MEANS THE ENTIRE LENGTH
AND HEIGHT OF WALL IS TO BE FINISHED OR FIRE-RATED AS
INDICATED.
20. WHEN NON-DIMENSIONED PARTITIONS APPEAR IN CONJUNCTION
WITH DOOR OPENINGS, THE DOOR WIDTH AND THE DOOR FRAME
DETAILS DETERMINE THE LOCATION OF ADJACENT WALLS AND
FRAMES.
21. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE
DETAILED. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN
INTENT CANNOT BE DETERMINED, CONSULT THE CONTRACTING
OFFICER BEFORE PROCEEDING WITH THE WORK.
22. THE CONTRACTOR MUST COORDINATE ALL MECHANICAL AND
ELECTRICAL FLOOR AND WALL SLEEVES INCLUDING CONDUITS
WITH ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE
PROTECTION, STRUCTURAL AND ARCHITECTURAL DRAWINGS.
23. PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES
AND AS REQUIRED FOR MECHANICAL EQUIPMENT AND PLUMBING
WORK. ALL ACCESS PANELS MUST BE CONCEALED AND
LOCATIONS MUST BE REVIEWED WITH THE ARCHITECT PRIOR TO
PROCEEDING.
24. ALL PIPE DUCTS AND BUS DUCTS THAT PENETRATE FLOOR SLABS
OR WALL PARTITIONS MUST BE INSTALLED IN A MANNER THAT
WILL PRESERVE THE MOISTURE RESISTIVENESS, FIRE RATING,
AND STRUCTURAL INTEGRITY OF THE BUILDING.
25. DO NOT CUT INTO, REMOVE OR ALTER ANY STRUCTURAL MEMBER
OR PORTION OF THE FLOOR SYSTEM UNLESS IT IS SPECIFICALLY
NOTED OR SHOWN ON THE STRUCTURAL DRAWINGS.
26. THE CONTRACTOR MUST PLAN HIS/HER WORK TO PROVIDE
ADEQUATE PROTECTION FOR PERSONS AND PROPERTY AT ALL
TIMES, AND EXECUTE THE WORK IN SUCH A MANNER TO AVOID
ANY HAZARD TO PERSONS AND PROPERTY AS NECESSARY.
27. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE COMPLETE
SECURITY OF THE SITE WHILE THE JOB IS IN PROGRESS AND
UNTIL THE JOB IS COMPLETE.
28. ALL DEBRIS MUST BE REMOVED FROM THE PREMISES BY
CONTRACTOR AND ALL ALL AREAS MUST BE LEFT IN CLEAN
CONDITION AT ALL TIMES.
29. CONTRACTOR MUST TAKE ALL NECESSARY PRECAUTIONS TO
ENSURE THE SAFETY OF THE STAFF AND WORKERS AT ALL TIMES.
30. THE CONTRACTOR MUST PROVIDE TEMPORARY WATER, POWER,
AND TOILET FACILITIES AS REQUIRED.
31. ALL CONSTRUCTION MUST COMPLY WITH ALL GOVERNING
BUILDING CODES AND ORDINANCES..
32. ALL EQUIPMENT MUST BE SECURELY MOUNTED TO THE FLOOR
PER OEM REQUIREMENTS AS WELL AS CODE REQUIREMENTS.
33. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF
SECURITY BADGE ACCESS REQUIREMENTS. COORDINATE
ACCESS REQUIREMENTS WITH USNPRC PROJECT MANAGER
MINIMUM OF ONE WEEK PRIOR TO BASE ACCESS.
GENERAL NOTES - CONTINUED
SCALE:
DETAIL, TITLE
1" = 20'-0"
S100
INDICATES DETAIL, NUMBER
DRAWING SCALE
NORTH ARROW
SECTION NUMBER
SHEET WHERE SECTION IS FOUND
BUILDING SECTION MARK
C100
DETAIL NUMBER, TYP.
AREA COVERED BY DETAIL
SHEET WHERE
DETAIL IS FOUND CALLOUT HEAD
SYMBOLS VIEW TITLES
PLAN SYMBOLS
ROOM NAME
101 ROOM
TAG
DOOR
NUMBER
STRUCTURAL
GRID
IDENTIFICATION
A KEYNOTE
TAG
WALL
TYPE
A
W1 VIEW WINDOW
NUMBER
AE301
AE301
AE301
ELEVATION (INTERIOR OR EXTERIOR)
ELEVATION NUMBER
SHEET WHERE ELEVATION IS FOUND
SHEET WHERE
DETAIL IS FOUND
S-# SIGNAGE
TYPE
APPLICABLE CODES AND STANDARDS
ABBREVIATIONS TITLE EDITION
IBC INTERNATIONAL BUILDING CODE 2021
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
Z:\
Jo bs \61
-A
US
DA
B1 Re no va te P1
La b - At he ns
G A\0
7 W ork ing Fo lde r\A rch \A-
1.d wg Ap r 2 3,
- 3 :18 pm c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
PARTIAL FIRST FLOOR PLANS
A-101
1 XX09/25/2024
RPP
RPP
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
P128
CHASE
P122
MECHANICAL
P125
JANITOR
PP-5
STAIR
P120
STORAGE
P119
FREEZER
P118
FREEZER
P117
FREEZER
P116
FREEZER
P115
FREEZER
P114
FREEZER
P113
FREEZER
P112
STORAGE
P101
CORRIDOR
P109
WOMEN
P110
MEN
P121A
WORK ROOM
ELEVATOR
P111
STORAGE
P121
ENGINEERING CENTER
7'-10"±
5'-6"14'-6"±
'-6
8'
4'45'-0"±
A-101
1 BUILDING 1 PARTIAL FLOOR PLAN
SCALE: 1/8"= 1'-0" A-101
2 BUILDING 1 PARTIAL REFLECTED CEILING PLAN
SCALE: 1/8"= 1'-0"
P128
CHASE
P122
STORAGE
P125
JANITOR
PP-5
STAIR
P120
STORAGE
P119
FREEZER
P118
FREEZER
P117
FREEZER
P116
FREEZER
P115
FREEZER
P114
FREEZER
P113
FREEZER
P112
STORAGE
P101
CORRIDOR
P109
WOMEN
P110
MEN
P121A
WORK ROOM
ELEVATOR
P111
STORAGE
P121
ENGINEERING CENTER
GENERAL NOTES
1. DIMENSIONS FROM FACE OF FINISHED WALL.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS.
3. EXISTING STRUCTURE IS EXPOSED. BOTTOM OF 2ND FLOOR SLAB IS PAINTED.
IN SHADED AREA, METAL DECKING IS EXPOSED AND UNPAINTED.
KEYED NOTES
1. NEW SINK (SEE PLUMBING)
2. REINSTALL EXISTING GATE IN NEW OPENING. PROVIDE FENCE POST
REQUIRED FOR HINGE AND LATCH POST.
3. EXISTING FREEZERS TO REMAIN.
4. SUSPENDED LIGHTS (SEE ELEC.)
5. SUSPENDED CABLE TRAY (SEE ELEC.)
6. PAINT CEILING (CONCRETE AND METAL) AND STRUCTURE
7. EXISTING METAL DECKING, PAINT (± 285 SQ. FT.)
8. EXTEND CMU WALL TO DECK ABOVE TO CLOSE OPENING ABOVE DOOR.
S-1
S-1
A A
A
A
A
A
B
A-201
BUILDING 1 - KEY PLAN
AREA OF
WORK
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
10'-10"
C
C
C
D
D
D
D
D
D
8"
8"
8"
8"
ROOM NUMBER
BRAILLE
ROOM NAME
BRAILLE
ENGINEERING
CENTER
P121
DOOR SCHEDULE
DOOR
WD HGT THK
SIZE
ELEV.
DOOR
MAT'L HEAD
FRAME
FIRE
RATING
LABEL
HDW
SET
NO
REMARKS
(2) 3'-0" 7'-0" A MTL -- HW-11 3/4" PAIR - PAINTED
JAMB SILL
4/A-201 5/A-201 --
(2) 3'-0" 7'-0" A MTL -- HW-11 3/4" PAIR - PAINTED4/A-201 5/A-201 --
103 3'-0" 7'-0" B MTL -- HW-21 3/4" EXIT ONLY6/A-201 7/A-201 --
ROOM NO ROOM NAME FLOOR BASE
MAT'L FINISH
EAST WALL
MAT'L FINISH
WEST WALL
MAT'L FINISH
NORTH WALL
MAT'L FINISH
SOUTH WALL
WALLS
MAT'L HEIGHT
CEILING NOTES
P111 EX GWB
MECHANICAL
WORKROOM
RES
RES 6" RB P
GWB/
EX CMU P GWB P P GWB PP121
P121A
P122
P P P
RES
STORAGE
ENGINEERING CENTER
RB
6" RB
P - - GWB P GWB P
P P P P
FINISH SCHEDULE
EXP FINISHES AT NEW PARTITIONS ONLY+/- 12'-8"
PAINT EXISTING EXPOSED
STRUCTURAL STEEL COLUMNS AND
BEAMS, PAINT UNDERSIDE OF
EXISTING CEILING DECK. EPOXY
PAINT TO 8' AFF.
EXP +/- 12'-8"
EXP +/- 12'-8"
EXP +/- 12'-8"
GWB/
EX. CMU
EX CMU EX CMU EX CMU EX CMU EX CMU
ABBREVIATIONS
EX EXISTING
EXP EXPOSED
GWB GYPSUM WALL BOARD
CMU CONCRETE MASONRY UNIT
RES RESINOUS COATING
RB RUBBER BASE - 4"
P PAINT
GWB/
EX CMU
GWB/
EX CMU
GWB/
EX CMU
GWB/
EX CMU
PAINT EXISTING EXPOSED
STRUCTURAL STEEL COLUMNS AND
BEAMS, PAINT UNDERSIDE OF
EXISTING CEILING DECK. EPOXY
PAINT TO 8' AFF.
PAINT EXISTING EXPOSED
STRUCTURAL STEEL COLUMNS AND
BEAMS, PAINT UNDERSIDE OF
EXISTING CEILING DECK. EPOXY
PAINT TO 8' AFF.
INTERIOR PARTITION
EXTEND PARTITION TO DECK AND
SEAL WITH ACOUSTICAL SEALANT
A
5/8" 3 5/8"
5/8"
5/8" GYP.BD.
3-5/8" METAL
STUDS @ 16" O.C.
5/8" GYP.BD.
3 12" SOUND
ATTENUATION
BLANKET
INTERIOR PARTITION INFILL
GYPSUM BOARD FURRING
TO 8'-0" AFF
B
5 5/8"
6" CMU BLOCK
5/8" GYP.BD.
5/8" GYP.BD.
7/8" MTL. FURRING
CHANNELS @ 16" O.C.
7/8" MTL. FURRING
CHANNELS @ 16" O.C.
INTERIOR PARTITION
GYPSUM BOARD FURRING
TO 8'-0" AFF
C
EXISTING WALL
CONSTRUCTION
5/8" GYP.BD.
5/8" GYP.BD.
7/8" MTL. FURRING
CHANNELS @ 16" O.C.
7/8" MTL. FURRING
CHANNELS @ 16" O.C.
INTERIOR PARTITION
GYPSUM BOARD FURRING
TO 8'-0" AFF
D
EXISTING WALL
CONSTRUCTION 5/8" GYP.BD.
7/8" MTL. FURRING
CHANNELS @ 16" O.C.
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
Z:\
Jo bs \61
-A
US
DA
B1 Re no va te P1
La b - At he ns
G A\0
7 W ork ing Fo lde r\A rch \A-
1.d wg Ap r 2 3,
- 3 :18 pm c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
SCHEDULES & DETAILS
A-201
1 XX12/10/2024
RPP
RPP
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
SCALE:
SIGNAGE SCHEDULE
NOT TO SCALE
A-201
S-1
SCALE:
PARTIAL WALL SECTION
1-1/2" = 1'-0"
A-201
EXISTING CONCRETE
FLOOR SLAB
6" CMU BLOCK INFILL AT
EXISTING OPENING
EXISTING STEEL
CHANNEL LINTEL
TO REMAIN
EXISTING CMU PARTITION
6' -8
VE
R
IF
Y)
HORIZONTAL REINFORCEMENT
@ 16" O.C. VERTICALLY
SCALE:
DOOR & FRAME ELEVATION
3/8" = 1'-0"
A-201
PAIR 1 3/4" THICK HEAVY DUTY
HOLLOW METAL DOORS AND
HOLLOW METAL FRAME
A
6" X 34" VISION
LITE --14" THICK
CLEAR GLASS
7' -0
2"
2" 6'-0" 2"
6"
HOLLOW METAL DOOR
HOLLOW METAL
DOOR FRAME
3-5/8" METAL STUDS
16" O.C.
DOUBLE STUDS
AT HEADER
2"
A-201
5 DOOR JAMB
SCALE: 3"= 1'-0"
HOLLOW METAL
DOOR FRAME
DOUBLE 3-5/8" METAL
STUDS AT JAMB
METAL JAMB ANCHORS
3 PER JAMB
CAULK PERIMETER
OF FRAME BOTH
SIDES
6"
2"
HOLLOW METAL DOOR
A-201
4 DOOR HEAD
SCALE: 3"= 1'-0"
SCALE: 1 1/2"=1'-0"
0 6" 1' 2'
SCALE: 3"=1'-0"
3"0 6" 1'
SCALE: 3/8"=1'-0"
0 1' 2' 4' 8'
7' 2"
2" 3' 2"
1 3/4" THICK HEAVY DUTY
HOLLOW METAL DOOR AND
HOLLOW METAL FRAME
B
EXISTING CMU
WALL
8" CMU LINTEL
BLOCK
PR. ∠5"X3"X3/8" LLV
MIN. BEARING 8"
EACH SIDE
CAULK PERIMETER
OF FRAME BOTH
SIDES
EXISTING CMU
WALL
CAULK PERIMETER
OF FRAME BOTH
SIDES
A-201
7 DOOR JAMB
SCALE: 3"= 1'-0"
A-201
6 DOOR HEAD
SCALE: 3"= 1'-0" SCALE:
PARTITION TYPES
NOT TO SCALE
A-2018'
-0 " W
AI
N
SC
O
T
AT
E
XI
ST
IN
G W
AL
LS
5/8" GYPSUM BOARD
WAINSCOT ON 7/8"
METAL FURRING
CHANNELS
METAL CORNER BEAD
2"
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
Z:\
Jo bs \61
-A
US
DA
B1 Re no va te P1
La b - At he ns
G A\0
7 W ork ing Fo lde r\M ec h\P
-10 1.d wg Ap r 2 3,
- 9 :45 am c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
PARTIAL FIRST FLOOR PLUMBING PLAN
P-101
1 XX12/10/2024
RPP
SME
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
P128
CHASE
P122
STORAGE
P125
JANITOR
PP-5
STAIR
P120
STORAGE
P119
FREEZER
P118
FREEZER
P117
FREEZER
P116
FREEZER
P115
FREEZER
P114
FREEZER
P113
FREEZER
P112
STORAGE
P101
CORRIDOR
P109
WOMEN
P110
MEN
P121A
WORK ROOM
ELEVATOR
P111
STORAGE
P121
ENGINEERING CENTER
GENERAL NOTES
1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PATCH DAMAGED
INSULATION, ADD INSULATION TO ALL DOMESTIC WATER PIPING
WHERE MISSING, AND TO PROTECT ALL EXISTING INSULATION IN
THE AREA OF WORK.
ROUTE SANITARY TO EXISTING FLOOR DRAIN.
ROUTE DOMESTIC HOT AND COLD WATER TO
EXISTING MAIN OVERHEAD. SEE DETAIL 4/P-601.
P-1
3/4" CA DOWN TO AIR HOSE REEL. MOUNT
HOSE REEL APPROX. 6'-6" AFF. USE RUBBER
AIR REEL STOPPERS TO MAKE ACCESS TO
AIR HOSE READILY AVAILABLE. PROVIDE
ADJUSTABLE WALL-MOUNTED PRESSURE
REGULATOR WITH VISIBLE PRESSURE GAUGE
PRIOR TO HOSE REEL CONNECTION.
LEGEND
EXIST.
LEGEND
AFF
CA
CP
DCW
DHW
FD
GCO
SSWR
TYP.
VTR
WCO
WH
ABOVE FINISHED FLOOR
COMPRESSED AIR PIPING
AIR COMPRESSOR
DOMESTIC COLD WATER PIPING
DOMESTIC HOT WATER PIPING
FLOOR DRAIN
GRADE CLEAN OUT
SANITARY SEWER PIPING
TYPICAL
VENT THROUGH ROOF
WALL CLEAN OUT
WATER HEATERCA
3/4" CA DOWN TO AIR HOSE REEL. MOUNT
HOSE REEL APPROX. 6'-6" AFF. USE RUBBER
AIR REEL STOPPERS TO MAKE ACCESS TO
AIR HOSE READILY AVAILABLE.PROVIDE
ADJUSTABLE WALL-MOUNTED PRESSURE
REGULATOR WITH VISIBLE PRESSURE
GAUGE PRIOR TO HOSE REEL CONNECTION.
CP-1
P-101
1 BUILDING 1 PARTIAL PLUMBING FLOOR PLAN
SCALE: 1/8"= 1'-0"
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
BUILDING 1 - KEY PLAN
AREA OF
WORK
P-101
1 BUILDING 1 PARTIAL PLUMBING EXISTING FLOOR PLAN
SCALE: 1/8"= 1'-0"
EXISTING FLOOR
DRAIN LOCATION
1" CA
1. ROUTE 3/4" DRAIN PIPING TO EXISTING MOP SINK LOCATED IN
JANITOR P125. PROVIDE EQUIPMENT PAD AND SPRING
ISOLATORS. SEE DETAIL 3/P-601.
X
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
Z:\
Jo bs \61
-A
US
DA
B1 Re no va te P1
La b - At he ns
G A\0
7 W ork ing Fo lde r\M ec h\P
-60 1.d wg Ap r 2 3,
- 9 :45 am c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
PLUMBING SCHEDULE AND DETAILS
P-601
1 XX12/10/2024
RPP
SME
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
12-7/8"
8"
-1
/4 " 12
-1
/2
SCALE:
SERVICE SINK DETAIL
NOT TO SCALE
2" WASTE & P-TRAP
INSULATED
18" 18"
72"
30-7/8"
P-601
PLUMBING FIXTURE SCHEDULE
MARK DESCRIPTION CW HW WASTE VENT BASIS OF DESIGN REMARKS
P-1 1/2" 1/2" 2" 2"SERVICE SINK KRATOS
(BOWL) 29N-006
WATERLOO
(FAUCET) 750FW812
PROVIDE TYPE 304 STAINLESS STEEL COMPARTMENT SINK WITH
GALVINIZED STEEL LEGS AND ADJUSTABLE BULLET FEET. PROVIDE
WITH 2 GPM AERATOR,CHROME-PLATED BRASS CONSTRUCTED
SWINGING SPOUT ON 8" CENTERS.
INTERIOR WALL
TERMINATED
SLEEVE FLUSH
WITH FINISHED
WALL SURFACES.
SEAL OR CAULK
SLEEVES THRU FIRE
WALLS IN A SMOKE
TIGHT MANNER,
WITH FIRE STOP
MATERIAL.
PIPE AND
INSULATION TO BE
CENTERED IN
SLEEVE. DO NOT
SUPPORT PIPE FROM
SLEEVE.
BACK UP MATERIAL
FINISHED WALL
WHERE EXPOSED,
PROVIDE FINISHED
ESCUTCHEON
PLATE FLUSH
AGAINST WALL,
AND OF SIZE TO
COMPLETELY
COVER OPENING.
STEEL PIPE
SLEEVE OF SIZE
TO PASS PIPE AND
INSULATION.
SCALE:
TYPICAL PIPE SLEEVES THRU WALLS
NOT TO SCALEP-601
3/8" TOGGLE BOLT HILTI
MODEL 00066365
BEAM CLAMP,
GALVANIZED, B-LINE,
MODEL B305
TUBING CLAMP. B-LINE
MODEL B2038
EXISTING
CONCRETE
BLOCK WALL
SCALE:
TYPICAL PIPE SUPPORT DETAIL
NOT TO SCALEP-601
18"18"
18"
SCALE:
SERVICE SINK WASTE
CONNECTION DETAIL
NOT TO SCALEP-601
EXISTING FLOOR DRAIN
SHUT-OFF VALVE
1/2" INSULATED DOMESTIC COLD
AND HOT WATER ROUTED TO
CONNECTION AT EXISTING MAINS
SHUT-OFF VALVE
1/2" INSULATED DOMESTIC COLD
AND HOT WATER ROUTED TO
CONNECTION AT EXISTING MAINS
EXISTING DOMESTIC COLD AND
HOT WATER MAINS
1" AIR MAIN
TAKE-OFF TOP
3/4" CA DROP
DOMESTIC CA REEL
W/50'-1/2" HOSE
LINCOLN MODEL
85010-50 OR
APPROVED EQUAL BALL VALVE
NOTE: HOSE REELS TO BE MOUNTED AT 6'-6"
ABOVE FINISH FLOOR.
P-601
5 TYPICAL HOSE REEL INSTALLATION
TYPEMARK MOTOR
POWER
(HP)
AIR COMPRESSOR SCHEDULE
5 597 460/3
BASIS OF
DESIGN
FLOW AT
MAX
PRESSURE
(CFM)
14CP-1 80
TANK
SIZE
(GAL)
WEIGHT
(LBS)
VOLTS/
PHASE
TWO STAGE INGERSOLL RAND
2475N5
MAX
PRESSURE
(PSIG)
SINK AND FAUCET PER
SCHEDULE FIXTURE
ADJUSTABLE PRESSURE REGULATOR
SPRING ISOLATORS(4)
CONCRETE PAD.
4" THICK LEVEL REINFORCED
DRAIN TRAP.
AUTOMATIC LIQUID
D
DUPLEX AIR COMPRESSOR PACKAGE MOUNTED
ON TANK. MOTORS PRE-WIRED TO STARTER AND
ALTERNATOR CONTROL PANEL. REQUIRES TWO
POWER CONNECTION WITH DISCONNECTS BY DIV. 16.
INTAKE AIR FILTER
PRESSURE RELIEF VALVE,
SET 100 PSIG
OIL FILTER
SCALE:
AIR COMPRESSOR DETAIL
NOT TO SCALEP-601
NOTE:
MOUNT SINK IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
x6 x1 x1 x1 x1 x1 x1
12"Ø x1
12x12
19x16 x8
12x8
12x8
12x8
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
Z:\
Jo bs \61
-A
US
DA
B1 Re no va te P1
La b - At he ns
G A\0
7 W ork ing Fo lde r\M ec h\M
D1
.dw g
Ap r 2
3,
- 9
:45 am c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
PARTIAL FIRST FLOOR
HVAC DEMOLITION PLAN
MD101
1 XX12/10/2024
RPP
SME
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
P128
CHASE
P122
STORAGE
P125
JANITOR
PP-5
STAIR
P120
STORAGE
P119
FREEZER
P118
FREEZER
P117
FREEZER
P116
FREEZER
P115
FREEZER
P114
FREEZER
P113
FREEZER
P112
STORAGE
P101
CORRIDOR
P109
WOMEN
P110
MEN
P111
STORAGE
P121
LAB
ELEVATOR
DEMOLITION KEYED NOTES
1. DISMANTLE AND REMOVE EXISTING DUCTWORK, INSULATION,
HANGERS, DAMPERS, GRILLES, REGISTERS, DIFFUSERS,
THERMOSTATS, AND ALL APPURTENANCES. REMOVE ALL DUCT
MOUNTED CONTROL DEVICES AND SENSORS.
2. DISMANTLE AND REMOVE EXISTING AIR HANDLING UNIT,
INSULATION, HANGERS, DAMPERS, CONTROL DEVICES AND ALL
APPURTENANCES.
3. DISMANTLE AND REMOVE EXISTING DEHUMIDIFICATION UNIT,
INSULATION, HANGERS, DAMPERS, CONTROL DEVICES AND ALL
APPURTENANCES.
4. DISMANTLE AND REMOVE EXISTING CONDENSING UNIT,
INSULATION, HANGERS, DAMPERS, CONTROL DEVICES AND ALL
APPURTENANCES. DEMOLISH EXISTING PIPING BACK TO
ISOLATION VALVES.
5. CAP EXISTING DUCTWORK TO REMAIN.
6. DISMANTLE AND REMOVE EXISTING UNIT HEATER, INSULATION,
HANGERS, CONTROL DEVICES AND ALL APPURTENANCES.
DEMOLISH EXISTING PIPING BACK TO ISOLATION VALVES.
CONTRACTOR IS RESPONSIBLE FOR PROPER ABATEMENT OF
INSULATION CONTAINING ASBESTOS.
7. EXISTING HYDRONIC PIPING TO REMAIN.
8. EXISTING LOUVER TO REMAIN.
9. EXISTING 1-1/2" CONDENSATE PIPING TO REMAIN.
X
LEGEND
POINT OF DEMOLITION
MD101
1 HVAC DEMOLITION FLOOR PLAN
SCALE: 1/8"= 1'-0"
EXISTING 1-1/2" CONDENSATE DOWN TO
EXISTING EQUIPMENT CONNECTION
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
BUILDING 1 - KEY PLAN
AREA OF
WORK
"Ø
"Ø
16"Ø
"Ø
"Ø
14"Ø
"Ø
"Ø
12"Ø
20"Ø x1
6"Ø8Ø
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
Z:\
Jo bs \61
-A
US
DA
B1 Re no va te P1
La b - At he ns
G A\0
7 W ork ing Fo lde r\M ec h\M
1.d wg Ap r 2 3,
- 9 :45 am c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
PARTIAL FIRST FLOOR HVAC PLAN
M-101
1 XX12/10/2024
RPP
SME
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
P128
CHASE
P122
STORAGE
P125
JANITOR
PP-5
STAIR
P120
STORAGE
P119
FREEZER
P118
FREEZER
P117
FREEZER
P116
FREEZER
P115
FREEZER
P114
FREEZER
P113
FREEZER
P112
STORAGE
P101
CORRIDOR
P109
WOMEN
P110
MEN
P121A
WORK ROOM
ELEVATOR
P111
STORAGE
P121
ENGINEERING CENTER
GENERAL NOTES
1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PATCH AND
PROTECT ALL EXISTING INSULATION IN THE AREA OF WORK.
SAG-1
SAG-1
SAG-1
SAG-1
SAG-1
SAG-1
SAG-1
SAG-1
SAG-1
SAG-1
SAG-1
SAG-1
SAG-1
RAG-1
RAG-1
RAG-1
RAG-1
RAG-1
RAG-1
RAG-1
RAG-1
ROUTE 10"x10" OUTDOOR
AIR INTAKE TO EXISTING
LOUVER. MODIFY SHEET
METAL CAP AS NEEDED FOR
DUCT CONNECTION
LEGEND
POINT OF RECONNECTION
WSHP-1
M-101
1 HVAC FLOOR PLAN
SCALE: 1/8"= 1'-0"
KEYED NOTES
1. PROVIDE UNIT WITH CONDENSATE PUMP AND ROUTE
INSULATED 3/4" CONDENSATE OVERHEAD TO EXISTING MOP
SINK LOCATED IN JANITOR P125. PROVIDE UNIT WITH EQUPMENT
PAD.
2. CONNECT 1-1/2" CONDENSER SUPPLY AND RETURN PIPING TO
EXISTING.
X
1-1/2" CONDENSER SUPPLY
AND RETURN PIPING
EF-1L-1
EAG-1
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
BUILDING 1 - KEY PLAN
AREA OF
WORK
CONDENSER SUPPLY
CONDENSER RETURN
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
Z:\
Jo bs \61
-A
US
DA
B1 Re no va te P1
La b - At he ns
G A\0
7 W ork ing Fo lde r\M ec h\M
-50 1.d wg Ap r 2 3,
- 9 :45 am c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
MECHANICAL DETAILS
M-501
1 XX12/10/2024
RPP
SME
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
20% MAXIMUM
AREA REDUCTION
R=H (MIN.)
L
W 15°H
W
L
DIM. "D"
ELEVATION
VIEW
PLAN
VIEW
DUCT DIM.
(SEE PLAN)
DUCT "VENTURI"
DEPRESSION DETAIL
NOTE: USE DETAIL
WHERE REQUIRED BY
FIELD CONDITIONS.
H R
TRANS.
DN.
TRANS.
UP
MIN. 2/3
"D"
TYPICAL
OBSTRUCTION TO
DUCT PATH
3"
CABLE WRAP
AROUND BEAM
AND BAR JOIST CL20
DUCTMATE
CLUTCHERS
WR20 CABLE
DUCT
DUCT
INSULATION
THREADED ROD
DOUBLE NUT
UNISTRUT OR
ANGLE
UNISTRUT BAR
BAR JOIST
CL20
DUCTMATE
CLUTCHER OR
EQUAL
DUCTMATE
WR20 CABLE
OR EQUAL
MINIMUM 3/8"
DIA. THREADED
ROD
12 GAUGE
GALVANIZED
STEEL
DUCT
DUCT
INSULATION
DOUBLE NUT
DUCT
EXTERNAL INSULATION WHERE
SPECIFIED
NOTE: FOR SIZES UP TO 60"
WITH 10' MAXIMUM SPACING.
NOTE: SEMI-CIRCLE
HANGER. 61"-72" DIAMETER
WITH 10' MAXIMUM
SPACING.
END VIEW ELEVATION VIEW
2"3 1/2" 1"
NOTE: FOR SIZES UP TO 60"
WITH 10' MAXIMUM SPACING.
SINGLE
DOUBLE
NOTE: 10' MAXIMUM SPACING.
97-120
85-96
72-84
61-72
DUCT SIZE (IN.) STRUT SIZE
1 5/8 X 1 5/8 X 12 GA
N/A
N/A
N/A
2 1/2 X 2 1/2 X 1/4
2 X 2 X 1/4
N/A
ANGLE SIZE
3 X 3 X 1/4
3/8
ROD SIZE
3/8
3/8
3/8
SCALE:
DUCT HANGER DETAILS
N.T.S
M-501
SCALE:
DUCT DEPRESSION FOR STRUCTURAL CONFLICTS DETAIL
N.T.S
M-501
PROVIDE MANUAL OPPOSED DAMPER IN EACH BRANCH LINE
UNLESS OTHERWISE NOTED ON DRAWINGS. DAMPERS SHALL
BE INSTALLED IN ACCESSIBLE LOCATION NEAR TRUNK DUCT
AND MINIMUM OF 5'-0" FROM ANY AIR INLET OR OUTLET
DEVICE. COORDINATE W/ ACCESS DOORS IN NON-ACCESSIBLE
CEILINGS.
TRUNK
DUCT
OVAL BRANCH
DUCT
45° CLINCH COLLAR PER SMACNA
USE AT ALL BRANCH TAPS
UNLESS
SPLITTER DAMPERS ARE
INDICATED.
BELL-MOUTH
FITTING
NOTE:
MANUAL BALANCING DAMPERS SHALL BE PROVIDED IN ALL BRANCH RUN-OUTS TO
DIFFUSERS, R.A AND EXHAUST GRILLES, UNLESS SPECIFICALLY NOTED OTHERWISE
ON DRAWINGS.
LOCATE DAMPERS SO THEY ARE ACCESSIBLE FROM LAY-IN CEILING OR ACCESS
DOORS.
ROUND
DUCT
SCALE:
BRANCH DUCT TAP DETAIL
N.T.S
M-501
SCALE:
HOUSE KEEPING PAD DETAIL
N.T.S
M-501
HOUSEKEEPING PADS MUST EXTEND
A MINIMUM OF 6" BEYOND ALL SIDES
OF SUPPORTED EQUIPMENT UNLESS
OTHERWISE INDICATED. PADS MUST
BE A MINIMUM OF 4" THICK
PROVIDE 3000 PSI CONCRETE
HOUSEKEEPING PADS FOR
ALL GROUND AND/OR FLOOR
MOUNTED EQUIPMENT
EDGE OF
SUPPORTED
EQUIPMENT
CHAMFERED
EDGED ALL
SIDES
FLOOR
ALL PADS INSTALLED ON CONCRETE
FLOORS ARE TO BE PROVIDED WITH #4
REBAR DOWEL RODS PENETRATING A
MINIMUM OF 2" INTO BOTH THE PAD
AND THE SUPPORTING FLOOR.
PROVIDE A MINIMUM OF FOUR (4)
DOWEL RODS PER PAD, WITH SPACING
OF DOWEL RODS AT 18" ON CENTER
MAXIMUM BOTH WAYS.
#4
REINFORCEMENT
MAX 4" ON
CENTER EACH
WAY
FLEXIBLE
CONNECTION
GASKETED
ACCESS
PANEL
ACOUSTICAL
LINING
SCALE:
IN-LINE EXHAUST FAN DETAIL
N.T.S
M-501
NOTES:
FRAMING
DUCT AS REQUIRED
FIXED BLADES
SEALANT
1. OVERALL SIZE OF OPENING SHOULD BE 1/4" OR 1/2" GREATER IN BOTH
DIRECTIONS THAN EXTERNAL DIMENSIONS OF LOUVER FOR SIZES < 48"
OR > 48", RESPECTIVELY.
2. MAXIMUM LOUVER WIDTH < 5FT, USE MULLION CONNECTED SECTIONS
FOR GREATER WIDTHS.
3. CAULK AND SEAL AROUND PERIMETER OF LOUVER SECTION AT WALL.
4. PROVIDE ALUMINUM OR GALV EXPANDED BIRD EXCLUSION SCREEN ON
OUTSIDE OF LOUVER. (MIN FREE AREA 80% OF GROSS AREA).
5. FOR AIR TIGHT SEAL PROVIDE VINYL GASKET ALONG FULL WIDTH OF
EACH BLADE.
6. CONSTRUCT LOUVER OF NON-FERROUS CORROSION RESISTANT
MATERIAL AND SECURE WITH SS OR ALUMINUM FASTENERS.
SCALE:
TYPICAL LOUVER DETAIL
N.T.S
M-501
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
Z:\
Jo bs \61
-A
US
DA
B1 Re no va te P1
La b - At he ns
G A\0
7 W ork ing Fo lde r\M ec h\M
-50 2.d wg Ap r 2 3,
- 9 :45 am c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
MECHANICAL DETAILS
M-502
1 XX12/10/2024
RPP
SME
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
CWR
CWS
NOTES:
1. CONTROL VALVE SHALL BE NORMALLY
CLOSED.
2. SUPPORT PIPING FROM FLOOR/CEILING
STRUCTURE. IN NO CASE SHALL WEIGHT OF
PIPING BE CARRIED BY COIL
3. STRUCTURAL TO PROVIDE BRACING FOR
ALL PIPING.
4. SEE SCHEDULE FOR RUN OUT PIPE SIZE AT
EACH COIL.
5. REFER TO FLOW DIAGRAM FOR LOCATION.
WSHP
WATER
COOLED
CONDENSER
OA MAIN
NOTES:
1. PROVIDE MANUAL VOLUME DAMPER AT EACH MAIN AT
EACH FLOOR, SUB-MAIN, BRANCH MAIN, AND BRANCH
TAKE-OFF. BRANCH DAMPER SHALL NOT SUBSTITUTE
FOR OBD AT TERMINAL.
2. PROVIDE CEILING ACCESS TO ALL DAMPERS
3. PROVIDE YOUNG REGULATOR OR DURO DYNE REMOTE
DAMPER ADJUSTMENT LINKAGE AND CEILING ACCESS
PLATE ASSEMBLY FROM CEILING AT HARD CEILINGS.
RA
OR
EA
AIR
MOVING
DEVICE
SCALE:
PIPE HANGER DETAILS
N.T.S
M-502
12" MIN
12" MIN
SINGLE PIPE CLEVIS
HANGER
U-CLAMP OR
CONDUIT
CLAMP
GALVANIZED
IRON TRAPEZE
OR UNISTRUT
16 GAUGE
GALVANIZED
SHEET SHIELD
WRAPPED FULLY
AROUND
INSULATION
INSULATION
PIPE
PROVIDE A SECTION OF
HIGH COMPRESSION
STRENGTH INSULATION AT
EACH HANGER POINT.
INSULATION SHALL BE HALF
ROUND AND EXTEND 2"
BEYOND GALVANIZED
SHIELD EACH WAY.
16 GAUGE
GALVANIZED
SHEET SHIELD
WRAPPED FULLY
AROUND
INSULATION
INSULATION
PIPE
HEAVY DUTY
CLEVIS
HANGER: MSS
SP-69 AND MSS
SP-58
PIPE
RIGID INSULATION INSERT
(12" LONG, 180^ ARC)
CLEVIS HANGER WITH
INSULATION SHIELD
INSULATION
BOLT & NUT
SUPPORT NUT
LOCKING NUT
TURNBUCKLE
W/LOCKNUT
HANGER ROD
SCALE:
CLEVIS HANGER DETAIL
N.T.S
M-502
MIN
MIN
3.5"
2" MIN
6.5"
DRAIN PAN
DRAIN LINE SHALL BE AT LEAST THE
SAME SIZE AS THE NIPPLE ON THE
DRAIN PAN. SEE PLANS FOR SIZES.
UNION
UNION FOR DRAINING
CLEAN OUT
SCALE:
CONDENSATE DRAIN P-TRAP DETAIL
N.T.S
M-502
NOTE:
INSULATE ALL CONDENSATE PIPING IN
BUILDING.
PIPE PENETRATION NOTES:
1. PROVIDE PITCH POCKET CONSTRUCTION, ADDITIONAL FLASHING, OR
WEATHER CAP AS REQUIRED FOR WATERPROOF CONSTRUCTION. DO NOT
MECHANICALLY ATTACH PIPE TO STRUCTURE IN ANY WAY.
2. SPACE BETWEEN PIPE AND SLEEVE SHALL BE FREE OF ANY FOREIGN
MATERIALS.
3. PIPE SHALL NOT CONTACT STRUCTURE AT ANY TIME. WEDGES ARE NOT BE
USED TO MAINTAIN PIPE POSITION.
4. PIPE MUST BE APPROXIMATELY CENTERED IN OPENING.
CAULK ALL JOINTS
AND SLEEVE ENDS
WATERTIGHT
PIPING
SCH. 40 PIPE STEEL SLEEVE
FOAM INSULATION OR
FIRE STOP MATERIAL
(FOR FIRE RATED
PARTITIONS)
PIPE INSULATION AS APPLICABLE
PARTITION
SCALE:
PIPE PENETRATION DETAIL
N.T.S
M-502
TOP OF COIL
FLEX CONNECTION (TYP.)
3/8'' MANUAL VENT COCK
WITH THREADED PIPE END
TEMPERATURE/PRESSURE TEST PORT (TYP.)
3-WAY CONTROL VALVE (3-WAY ONLY REQUIRED AT COIL
LOCATIONS INDICATED ON MECHANICAL DRAWINGS PROVIDE
STANDARD 2-WAY CONTROL VALVE ELSEWHERE)
UNION (TYP.)
BALANCING VALVE
COMBINATION BALANCING
VALVE & FLOW INDICATOR
THERMOMETER (TYP.)
SHUTOFF
VALVE (TYP.)
3/4'' DRAIN WITH
HOSE END
BRANCH MAIN
SUB-MAIN (2 OR
MORE BRANCH
MAINS)
MVD AT EACH MAIN DUCT TAKE-OFF
AT RISER AT EACH FLOOR (TYP)
LOCATE EACH MVD
AT EACH DUCT
TAKE-OFF (TYP)
RA BRANCH
PROVIDE W/OBD
EA BRANCH
PROVIDE W/OBD
STRAINER
SCALE:
WSHP CONDENSER WATER CONNECTION DETAIL
N.T.S
M-502
SCALE:
MANUAL VOLUME DAMPER DETAIL (MVD)
N.T.S
M-502
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
Z:\
Jo bs \61
-A
US
DA
B1 Re no va te P1
La b - At he ns
G A\0
7 W ork ing Fo lde r\M ec h\M
-60 1.d wg Ap r 2 3,
- 9 :45 am c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
MECHANICAL SCHEDULES AND DETAILS
M-601
1 XX12/10/2024
RPP
SME
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
NOTES:
1. SUBMIT FINISH/FRAME STYLE OFF ALL DEVICES FOR REVIEW.
2. PROVIDE WITH ALUMINUM CONSTRUCTION.
GRILLE, REGISTER AND DIFFUSER SCHEDULE
MARK TYPE USE
S
PANEL
SIZE IN.
NECK
SIZE IN.
MAX CFM MAX PD
IN. WC FINISH PATTERN REMARKSR E
MAX. NOISE
CRITERIA (NC)
NOTES:
1. PROVIDE LOUVER WITH ALUMINUM INSECT SCREEN.
2. ALL LOUVERS MUST BE FLORIDA PRODUCT APPROVED.
MARK DESCRIPTION REMARKSAPPLICATION WIDTH
(IN)
HEIGHT
(IN)
FREE
AREA
(SF)
VOLUME
(CFM)
PRESSURE
DROP
(IN WG)
FREE
AREA
VELOCITY
(FPM)
BEGINNING POINT
OF WATER
PENETRATION,
BPWP (FPM)
L-1 SEE NOTES
BASIS
OF
DESIGN
MAKE
BASIS
OF
DESIGN
MODEL
FIXED BLADE
HURRICANE LOUVER
12 GREENHECK EHV-550EXHAUST 12 0.2 70 0.04 308
LOUVER SCHEDULE
DEPTH
(IN)
16X12 16X12 SIDEWALL SEE NOTESXSAG-1 DUCT MOUNTED
LOUVERED GRILLE 550
OFF
WHITE0.025 12
16X12 16X12 SIDEWALL SEE NOTESXRAG-1 DUCT MOUNTED
LOUVERED GRILLE 550
OFF
WHITE0.025 12
EAG-1 110 PERF. SEE NOTESCEILING MOUNTED
PERFORATED GRILLE X 12X12 6Ø
MATCH
CEILING0.025 15
WATER SOURCE HEAT PUMP (PART 1 OF 2)
OA
AIRFLOW
(TOTAL)
ESP
(IN H2O)
TSP
(IN H2O) TOTAL
MBH
SENS
MBH
EAT °F
(DB/WB)
EWT
(°F)
FLOW
(GPM)
WPD
(FT)
LAT °F
(DB/WB)
LWT
(°F)
COOLING
CAPACITY AIR SIDE WATER SIDEMARK TYPE SERVES HP
(EACH)
SUPPLY FAN
P121 &
P121A 240 127.22.0 89.2 57/53.7 70.3 90.1WSHP-1
NOTES:
1. ALL UNITS TO BE DOUBLE WALL WITH HINGED ACCESS DOORS.
2. PROVIDE UNITS WITH VARIABLE FREQUENCY DRIVE(S) AND SINGLE POINT POWER CONNECTIONS. COORDINATE WITH ELECTRICAL.
3. PROVIDE SMOKE DETECTORS IN SUPPLY AND RETURN DUCTS. COORDINATE WITH ELECTRICAL AND FIRE ALARM.
4. INTERLOCK AHU(S) VIA BAS TO DE-ENERGIZE ON ANY FIRE ALARM/SMOKE DETECTION IN THE BUILDING.
5. PROVIDE DISPOSABLE MERV 13 FINAL FILTERS.
6. PROVIDE UNIT WITH CONDENSATE PUMP.
VERTICAL
FLUID
WATER
BASIS
OF
DESIGN
TRANE 15.0 4.81.5
VOLTS/
PHASE
OPER.
WEIGHT
(LBS) REMARKS
SEE NOTES460V/3PH 857
PRE /
FINAL
FILTERS
NONE/
MERV 13
MOP
ELECTRICAL
AIRFLOW
MONITORING
STATION
LOCATION
OA INTAKE
DUCT
TOTAL
MBH
EAT °F
(DB)
EWT
(°F)
FLOW
(GPM)
WPD
(FT)
LAT °F
(DB)
LWT
(°F)
HEATING
CAPACITY AIR SIDE WATER SIDE
126.1 56.8 105.8 70.3 56.8
FLUID
WATER 15 4.8
WATER SOURCE HEAT PUMP (PART 2 OF 2)
TOTAL
AIRFLOW
(CFM)
MCA
20.65
FLA
18.70
80.6/66.21.5
EXHAUST FAN SCHEDULE
BASIS
OF DESIGN MAX
SONES
VOLTS/
PHASE FLA MCA MOP OTHER AS
NOTED
OPER.
WEIGHT
(LBS)
MARK
RPMDRIVES.P.
IN.WC.
AIRFLOW
CFM
FAN DATA ELEC. DATA
POWER
HP
CONTROL INTERLOCKS
SWITCH
REMARKSFAN
TYPE
EF-1 70 VARIABLENO 271/151.911640.2 SEE NOTESCENT. 1.3 1.6 15115/1DIRECTGREENHECK
SQ-70-VG
TYPE
INLINE
NOTES:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
2. PROVIDE WITH GRAVITY BACKDRAFT DAMPER.
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
Z:\
Jo bs \61
-A
US
DA
B1 Re no va te P1
La b - At he ns
G A\0
7 W ork ing Fo lde r\M ec h\M
-70 1.d wg Ap r 2 3,
- 9 :45 am c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
BUILDING 1, U.S. NATIONAL POULTRY RESEARCH CTR.
RENOVATE ROOM P111
ATHENS, GEORGIA
MECHANICAL CONTROLS
M-701
1 XX12/10/2024
RPP
SME
CG
SOUTHEAST AREA
STONEVILLE, MS
XXX
6124-A
XXX
XXX
XXX
XXX
ROOM THERMOSTAT WITH:
· DISPLAY
· ON/OFF CONTROL
· TEMPERATURE SETPOINT
ADJUSTMENT
· FAN SPEED ADJUSTMENT REFER TO FLOOR PLANS
FOR 3 WAY VALVE LOCATIONS
AI
T
INTEGRAL UNIT
CONTROLLER
AND SINGLE
POINT POWER
CONNECTION
CSR
E
DO
DI
START / STOP
RUN STATUS
CWR
CWS
T
AI
RA SA
WSHP
DO
DI
LAN TRUNK TO
OTHER DDC
CONTROLLER
A. THE WATER SOURCE HEAT PUMP UNIT SHALL BE CONTROLLED
BY A MANUFACTURER SUPPLIED BACNET CONTROLLER
INTEGRATED INTO THE BMS TO MAINTAIN THE ZONE
TEMPERATURE AT SETPOINT.
B. SCHEDULING: THE WATER SOURCE HEAT PUMP SYSTEM WILL BE
ENABLED BASED ON A TIME-OF-DAY (TOD) SCHEDULE AND SYSTEM
DEMAND AS INDICATED BY ZONE THERMOSTAT OR AS
PROGRAMMED BY THE BUILDING OPERATOR. SYSTEM OPERATION
SHALL BE ALLOWED AT ALL TIMES.
C. MODES OF OPERATION:
C.1. OCCUPIED MODE: DURING OCCUPIED MODE, ENABLE OPERATION
OF HEAT PUMP UNIT AND THE CONDENSER WATER SYSTEM AND
OPEN THE WSHP ISOLATION VALVE. THE REVERSING VALVE AND DX
COMPRESSORS SHALL BE STAGED AS REQUIRED TO MAINTAIN THE
SPACE TEMPERATURE HEATING (68F) AND COOLING (78F)
SETPOINTS (ADJ.). THE SUPPLY FAN SHALL RUN CONTINUOUSLY.
C.2. UNOCCUPIED MODE: DURING UNOCCUPIED MODE, DISABLE
OPERATION OF HEAT PUMP UNIT AND THE CONDENSER WATER
PLANT AND CLOSE THE WSHP ISOLATION VALVE. THE WSHP SHALL
CYCLE ON TO MAINTAIN THE UNOCCUPIED SPACE TEMPERATURE
SETBACK HEATING(55F) AND COOLING(85F) SETPOINTS (ADJ.). WHEN
A WALL SENSOR OVERRIDE BUTTON IS DEPRESSED DURING
UNOCCUPIED PERIOD, OPERATE THE SYSTEM IN OCCUPIED MODE
FOR ONE HOUR (ADJ.).
C.3. DEMAND SHED: UPON RECEIPT OF A DEMAND SHED SIGNAL, ALL
NON-CRITICAL ZONES SHALL RESET THEIR HEATING SETPOINT
DOWN BY 4°F AND THEIR COOLING SETPOINT UP BY 4°F. THE
DEMAND SHED MODE SHALL BE MANUALLY ENABLED OR DISABLED
BY AN OPERATOR BUTTON ON THE GRAPHICAL USER INTERFACE AS
WELL AS BY AN AUTOMATIC CAMPUS SIGNAL.
D. DX CYCLE CONTROL: INCORPORATE COMPRESSOR MINIMUM ON
TIME, COMPRESSOR MINIMUM OFF TIME, AND COMPRESSOR
ON/OFF DELAYS FOR PERIODS RECOMMENDED BY THE WSHP
MANUFACTURER.
OUTDOORS
ROOM
EF-DPS
L H
120 VAC NH
EXHAUST FAN TERMINALS
HAND OFF
AUTO
EF
STR
COIL
OVERLOADS
SEQUENCE OF OPERATION
CONTROL OF EF-1:
EXHAUST FAN MUST BE IN OPERATION
CONTINUOUSLY.
FUNCTION
PROOFS
& SAFETIES
EF-S EXHAUST FAN STATUS ON/OFF EXHAUST FAN FAILED TO START INFO
START/STOP EF-SS EXHAUST FAN START/STOP COMMAND ON/OFF
NOTES:
1. THE CONTRACTOR SHALL COMPLETE THE POINTS SCHEDULE AS INDICATED IN THE SPECIFICATION AND IN ACCORDANCE WITH THIS DRAWING.
SCALE:
EXHAUST FAN CONTROLS
NTS
DDC
CHWP1-SS
CHWP1-S
POINT NAME DESCRIPTION
SETTING
(WITH UNITS)
RANGE
(WITH UNITS)
IO
TYPE
ALARM CONDITION
(SEE NOTES)
ALARM
PRIORITY
ALARMING
BI
BO
M-701
SCALE:
WATER SOURCE HEAT PUMP CONTROLS
NTS
M-701
ELECTRICAL GENERAL NOTES:
1. THE WORK MUST CONFORM WITH ALL REQUIREMENTS OF:
· NFPA 70, NATIONAL ELECTRICAL CODE (NEC) (2020)
· NFPA 101, LIFE SAFETY CODE (2018)
· NFPA 780, STANDARDS FOR INSTALLATION OF LIGHTNING PROTECTION SYSTEMS (2020)
· IEEE C2, NATIONAL ELECTRICAL SAFETY CODE (NESC) (2017)
· UFC 1-200-01, DOD BUILDING CODE (GENERAL BUILDING REQUIREMENTS),
· UFC 1-200-02, HIGH PERFORMANCE AND SUSTAINABLE BUILDING REQUIREMENTS
· UFC 3-501-01, ELECTRICAL ENGINEERING
· UFC 3-520-01 INTERIOR ELECTRICAL SYSTEMS
· UFC 3-530-01, INTERIOR AND EXTERIOR LIGHTING AND CONTROLS
· UFC 3-550-01, EXTERIOR ELECTRICAL POWER DISTRIBUTION
· UFC 3-560-01, OPERATION AND MAINTENANCE: ELECTRICAL SAFETY
· UFC 3-575-01, LIGHTNING AND STATIC ELECTRICITY PROTECTION SYSTEMS
· UFC 3-580-01, TELECOMMUNICATIONS BUILDING CABLING SYSTEMS PLANNING AND DESIGN
· UFC 4-010-01, DOD ANTITERRORISM STANDARDS FOR BUILDINGS
· UFC 4-011-06, CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS
· ASHRAE 90.1, ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS (2013)
*CRITERIA AND STANDARDS LISTED ALSO INCLUDE SPECIFIED STANDARDS AND RELATED SECTIONS AS PART OF THE DESIGN.
2. MINIMUM RACEWAY SIZE MUST BE 3/4". INCREASE RACEWAY SIZE AS REQUIRED TO LIMIT RACEWAY FILL RATIO TO LESS THAN 40% FULL FOR FEEDERS
AND 20% FOR BRANCH CIRCUITS IAW CNIFR REQUIREMENTS.
3. THE ELECTRICAL CONTRACTOR MUST CAREFULLY COORDINATE WORK WITH OTHER TRADES THROUGH THE GENERAL CONTRACTOR AND MUST BE RESPONSIBLE FOR SECURING SPACE REQUIREMENTS FOR ELECTRICAL EQUIPMENT CLEARANCE FOR RECESSED LUMINAIRES AND CORRECT ROUGH-IN
LOCATIONS OF ELECTRICAL CONNECTIONS.
4. VERIFY DOOR SWINGS WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING IN WALL SWITCHES. SWITCHES IN THE SAME LOCATION MUST BE GANGED
TOGETHER IN ONE COMMON BACKBOX AND MUST HAVE ONE COMMON FACE PLATE.
5. ALL FEEDERS AND BRANCH CIRCUITS MUST INCLUDE A GREEN INSULATED GROUND CONDUCTOR, SIZE PER NATIONAL ELECTRICAL CODE, OR AS SHOWN, CONNECTED TO EACH DEVICE AND OUTLET BOX ON THE CIRCUIT AND TO THE PANELBOARD GROUND BUS. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. MULTIPLE BRANCH CIRCUITS IN ONE RACEWAY REQUIRE ONLY ONE GROUND CONDUCTOR.
6. VERIFY LUMINAIRE, CEILING MOUNTED OCCUPANCY SENSOR LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS AND DIMENSIONS PRIOR TO INSTALLATION. VERIFY EXACT LOCATIONS OF MOTORS AND EQUIPMENT BEFORE ROUGHING-IN.
7. EXISTING ELECTRICAL WORK (NOT SHOWN) MUST REMAIN, UNLESS INDICATED OTHERWISE. SHOULD ANY EXISTING ELECTRICAL POWER, LIGHTING OR AUXILIARY CIRCUIT, FEEDER OR EQUIPMENT BE SEVERED, DISCONNECTED OR DELETED IN THE PROCESS OF CONSTRUCTION OR REMODELING WHICH IS DONE AS A RESULT OF CONTRACT PLANS AND SPECIFICATIONS, AND UNLESS SPECIFICALLY DESIGNATED BY THE DRAWINGS TO BE DELETED, THEN SAID CIRCUIT OR FEEDER MUST BE RESTORED TO WORKING CONDITION. THE RESTORATION MUST INCLUDE RE-ROUTING, RELOCATION, RECONNECTION OR REPLACEMENT AS MAY BE REQUIRED BY THE NEW WORK. ANY SUCH WORK REQUIRED MUST BE INCLUDED IN THE CONTRACT AND NO EXTRA COMPENSATION
WILL BE GRANTED.
8. NEW WORK MUST BE MADE TO TIE INTO THE EXISTING IN A UNIFORM MANNER, SIMILAR ITEMS OF NEW WORK MUST BE CHECKED AGAINST EXISTING
WORK
9. REFER TO ONE-LINE DIAGRAMS, SCHEDULES AND RISER DIAGRAMS FOR CONDUCTOR AND CONDUIT SIZES NOT SHOWN ON PLANS.
10. PROVIDE IS AN INCLUSIVE TERM USED TO DESCRIBE ASPECTS OF THE WORK TO BE ACCOMPLISHED, AND IS HEREBY DEFINED TO REQUIRE TO STORE, FURNISH, INSTALL, MOUNT, CONNECT, CONTROL AND POWER EQUIPMENT INDICATED, AS WELL AS ALL APPURTENANCES REQUIRED TO MAKE ELECTRICAL SYSTEMS OPERATE AS INDICATED WITHIN THESE DRAWINGS AND SPECIFICATIONS AND TO FULFILL THE SCOPE OF WORK.
11. DEMOLISH IS AN INCLUSIVE TERM USED TO DESCRIBE ASPECTS OF THE WORK TO BE ACCOMPLISHED, AND IS HEREBY DEFINED TO REQUIRE CONTRACTOR TO DISCONNECT EQUIPMENT FROM ALL CONNECTIONS, REMOVE FROM THE OWNER'S SITE, AND DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL LAWS AND ORDINANCES. COST OF DISPOSAL IS ENTIRELY THE CONTRACTOR'S RESPONSIBILITY.
12. ALL CONDUCTORS ARE COPPER UNLESS SPECIFICALLY NOTED AS ALUMINUM.
13. CONTRACTOR MUST FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE PROCUREMENT OF ANY MATERIALS AND
DEVELOPMENT OF ANY SHOP DRAWINGS OR SUBMITTALS.
14. PROVIDE LABELS ON ALL RECEPTACLES, WALL MOUNTED LIGHT SWITCHES/OCCUPANCY SENSORS AND JUNCTION BOXES INDICATING THE SOURCE PANEL & CIRCUIT(S). TEXT MUST BE BLACK, 1/4" IN HEIGHT PRINTED ON A CLEAR LABEL. HANDWRITTEN LABELS ARE NOT PERMITTED EXCEPT FOR JUNCTION BOXES LOCATED ABOVE FINISHED CEILING WHICH CAN BE HANDWRITTEN WITH AN INDELIBLE MARKER.
15. ALL EQUIPMENT PADS FOR INTERIOR ELECTRICAL EQUIPMENT MUST BE FLUSH WITH FRONT SIDE OF EQUIPMENT AND EXTEND AT LEAST 2" BEYOND
THE FOOTPRINT OF THE EQUIPMENT ON ALL OTHER SIDES.
ELECTRICAL ABBREVIATIONS:
A OR AMP
ACC
AC
AC
AF
AFF
AFG
AHU
AIC
AL
AM
ASYM
AT
ATS
AUTO
AWG
B
BC
BCW
BFF
BFG
BLDG
BMGB
C
CAT
CB
CCT
CCTV
CFCI
CH
CHWCP
CHWP
CHWSP
CKT
CMH
CMS
CP
CPT
CRAC
CRI
CT
CT
CU
CWP
D
DC
DF
DH or DUH
DHWCP
DISC
DOAS
DPST
DPDT
DSCU
DSHP
DSS
DWBP
DX
EC
ECB
EF
ELEC
EMH
EMT
E or EMER
EPA
EQUIP
ERV
ERU
EXIST or EX
EUH
EXP
EWC
EWH
F
FACP
FCU
FLEX
FWE
G OR GND
GFGI
GFI
GRS
GUH
GWH
H or HT
HAC
HOA
HP
HP
HT
HVU
HWCP
HWP
HWRP
HWSP
AMPERE(S)
AIR COOLED CHILLER
ALTERNATING CURRENT
AIR COMPRESSOR / AIR CURTAIN
AMP FRAME
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR HANDLING UNIT
AMPERE INTERRUPTING CAPACITY
ALUMINUM
AMMETER
ASYMMETRICAL
AMP TRIP
AUTOMATIC TRANSFER SWITCH
AUTOMATIC
AMERICAN WIRE GAUGE
BOILER
BRANCH CONTROLLER
BARE COPPER WIRE
BELOW FINISHED FLOOR
BELOW FINISHED GRADE
BUILDING
BUILDING MASTER GROUNDING BUSBAR
CONDUIT
CATEGORY
CIRCUIT BREAKER
CORRELATED COLOR TEMPERATURE
CLOSED CIRCUIT TELEVISION
CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CHILLER
CHILLED WATER CIRCULATING PUMP IN A PRIMARY-SECONDARY SYSTEM
CHILLED WATER PUMP
CHILLED WATER SUPPLY PUMP IN A PRIMARY-SECONDARY SYSTEM
CIRCUIT
COMMUNICATIONS MANHOLE
COMBINATION MOTOR STARTER
CONDENSATE PUMP
CONTROL POWER TRANSFORMER
COMPUTER ROOM AC UNIT
COLOR RENDERING INDEX
CURRENT TRANSFORMER
COOLING TOWER
COPPER OR CONDENSING UNIT
CONDENSER WATER PUMP
DEPTH
DIRECT CURRENT
DESTRATIFICATION FAN
DUCT HEATERS
DOMESTIC HOT WATER CIRCULATING PUMP
DISCONNECT SWITCH
DEDICATED OUTSIDE AIR SYSTEM (UNIT)
DOUBLE POLE SINGLE THROW
DOUBLE POLE DOUBLE THROW
DUCTLESS SPLIT CONDENSING UNIT (POWERS THE DSS INDOOR UNIT)
DUCTLESS SPLIT HEAT PUMP (POWERS THE DSS INDOOR UNIT)
DUCTLESS SPLIT SYSTEM (INDOOR UNIT)
DOMESTIC WATER BOOSTER PUMP
DIRECT EXPANSION (DX) COOLING COIL
EMPTY CONDUIT
ENCLOSED CIRCUIT BREAKER
EXHAUST FAN
ELECTRICAL
ELECTRICAL MANHOLE
ELECTRICAL METALLIC TUBING
EMERGENCY
EFFECTIVE PROJECTED AREA
EQUIPMENT
ENERGY RECOVERY VENTILATOR
ENERGY RECOVERY UNIT
EXISTING
ELECTRIC UNIT HEATER
EXPLOSION PROOF
ELECTRIC WATER COOLER
ELECTRIC WATER HEATER
FUSE
FIRE ALARM CONTROL PANEL
FAN COIL UNIT
FLEXIBLE
FURNISHED WITH EQUIPMENT
GROUND
GOVERNMENT FURNISHED GOVERNMENT INSTALLED
GROUND FAULT INTERRUPTER
GALVANIZE…