ATTACHMENT 5 DRAWINGS 549-20-222.pdf

PDF 44 MB Posted

Attached to
Y1DA--Renovate Dallas Medical Inpatient Unit For Patient Privacy & Pandemic (VA-24-00008151)
Solicitation number
36C25724R0005
Issued by

About this file

The document provided is Attachment 5 Drawings 549-20-222.pdf, which appears to be a set of technical drawings related to the federal contract opportunity Solicitation Number: 36C25724R0005, titled "Y1DA--Renovate Dallas Medical Inpatient Unit For Patient Privacy & Pandemic (VA-24-00008151)".

This solicitation is a Request for Proposal (RFP) for a firm fixed price construction contract project issued by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 17. The acquisition is a 100% competitive Small Business Set-Aside under NAICS code 236220. The drawings likely provide detailed specifications and design requirements for the renovation work to be performed under this contract.

View the file

Other files

File Type Posted
36C25724R0005 A0008 Conformed Solicitation.pdf PDF
36C25724R0005 0008.docx DOCX document
RFI Responses Part 5 Floor Plans Only.pdf PDF
RFI Responses Part 3.pdf PDF
RFI Responses Part 4.xlsx XLSX spreadsheet
36C25724R0005 0007.docx DOCX document
36C25724R0005 Site Visit Attendance List 2024.06.27.pdf PDF
36C25724R0005 0006.docx DOCX document
36C25724R0005 RFI Responses Part 1.pdf PDF
36C25724R0005 0005.docx DOCX document
36C25724R0005 RFI Responses Part 1.pdf PDF
36C25724R0005 A0005 Conformed Solicitation.pdf PDF
36C25724R0005 RFI Responses Part 2.pdf PDF
VA Medical Center Dallas Texas Building 2 AHERA Asbestos Inspection and Management Plan.pdf PDF
36C25724R0005 0004.docx DOCX document
36C25724R0005 Site Visit Attendance List.pdf PDF
36C25724R0005 0003.docx DOCX document
36C25724R0005 0002.docx DOCX document
36C25724R0005 A0002 Conformed Solicitation.pdf PDF
36C25724R0005 A0001.docx DOCX document
36C25724R0005 A0001 Updated Solicitation.pdf PDF
36C25724R0005 0001.docx DOCX document
36C25724R0005 A00001 Updated Solicitation.pdf PDF
ATTACHMENT 3 BACKGROUND INVESTIGATION.docx DOCX document
36C25724R0005_1.docx DOCX document
ATTACHMENT 7 VHA PCRA 2023_1.0.pdf PDF
ATTACHMENT 2 PAST PERFORMANCE QUESTIONNAIRE.docx DOCX document
ATTACHMENT 1 RELEASE OF CLAIMS.docx DOCX document
ATTACHMENT 8 SITE VISIT LOCATION.pdf PDF
ATTACHMENT 4 SPECIFICATIONS 549-20-222.pdf PDF
ATTACHMENT 6 VHA ICRA 2023_1.0.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

ISSUE FOR BID

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Engineering

B

IM

/V

A D

A

T H

F L O

O R

/5 -2

-2

-M

E -R

.r v t

/2

/2

:4 :1

A

M

2-GI-1.0

COVER SHEET / INDEX

O'Brien Engineering, Inc., Managing Partner

2340 E. Trinity Mills Rd. Ste 220

Carrollton, TX 75006

972-233-2288 www.obrieneng.com

O'Brien Engineering, Inc.

2340 E. Trinity Mills Rd Ste 220

Carrollton, TX 75006

972-233-2288 www.obrieneng.com

RENOVATE MEDICAL INPATIENT

UNIT FOR PATIENT PRIVACY &

COVID-19

DALLAS, TEXAS

549-20-222

Mr. Alex Muller-Poitevien, COR

11/04/2022 JEL TEB

OEI-LBL Joint Venture LLC

VA NORTH TEXAS HEALTH CARE SYSTEMS

DALLAS, TEXAS

RENOVATE MEDICAL INPATIENT UNIT FOR

PATIENT PRIVACY & COVID-19 : 549-20-222

Revisions: Date:

CHIEF OF STAFF

Womens Veterans Program Manager

2-GI-1.1A

SHEET INDEX

JL JM

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

ISSUE FOR BID

FULLY SPRINKLERED

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

MEP

O'Brien Engineering, Inc., Managing Partner 2340 E. Trinity Mills Rd. Ste 200 Carrollton, TX 75006 972-233-2288 www.obrieneng.com

OEI-LBL Joint Venture LLCO'Brien Engineering, Inc.

2340 E. Trinity Mills Rd Ste 220 Carrollton, TX 75006 972-233-2288 www.obrieneng.com

Mr. Alex Muller-Poitevien, COR

RENOVATE MEDICAL INPATIENT

UNIT FOR PATIENT PRIVACY &

COVID-19

DALLAS, TEXAS

549-20-222

11/04/2022Revisions: Date:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

O EI O EI - LBL

P:\0489001.006 VADA 8th Floor\0-Templates and Covers\Dwg\Sheets\549.20-222 - 2-GI-1.0A SHEET INDEX.dwg, 9/22/2021 9:21:45 AM, DWG To PDF.pc3

SHEET

NUMBER SHEET NAME SHEET

NUMBER SHEET NAME SHEET

NUMBER SHEET NAME

2-GI-1.0 COVER SHEET 2-PD-2.1 PLUMBING DEMOLITION PLAN 2-E-0.1 GENERAL NOTES AND ABBREVIATIONS 2-GI-1.0A SHEET INDEX 2-PG-2.1 LEVEL 8 MEDICAL GAS PLUMBING OVERALL PLAN 2-E-0.1 GENERAL NOTES AND ABBREVIATIONS 2-GI-1.1 GENERAL INFORMATION 2-PG-2.2 LEVEL 8 MEDICAL GAS PIPING PLAN - AREA 100-A 2-E-0.2 ELECTRICAL LEGEND 2-GI-1.2 LIFE SAFETY DATA/PLAN 2-PG-2.3 LEVEL 8 MEDICAL GAS PIPING PLAN - AREA 300 2-E-0.2 ELECTRICAL LEGEND 2-GI-1.3 SITE & PHASING PLAN 2-PG-2.4 LEVEL 8 MEDICAL GAS PIPING PLAN - AREA 200-A 2-ED-1-1 LEVEL 8 - ENLARGED DEMO - AUX FLOORPLAN

2-PG-2.5 LEVEL 8 MEDICAL GAS PIPING PLAN - AREAS 100-B & 200-B 2-EP-1-1 LEVEL 8 - ENLARGED ELECTRICAL POWER FLOORPLAN 2-PP-0.1 PLUMBING ABBREVIATIONS AND GENERAL NOTES 2-EP-1-4 LEVEL 9 - ELECTRICAL POWER ROOF PLAN

2-AI-2.0 LEVEL 7 REFERENCE FLOOR PLAN 2-PP-3.0 LEVEL 8 OVERALL PLUMBING PLAN 2-EP-1.1A LEVEL 8 - POWER PLAN - SUITE 100 2-AI-2.1 LEVEL 8 OVERALL FLOOR PLAN 2-PP-3.1 LEVEL 8 PLUMBING ENLARGED PLAN - AREA 100-A 2-EP-1.1B LEVEL 8 - POWER PLAN - SUITE 300 2-AI-2.2 LEVEL 8 ENLARGED FLOOR PLAN- AREA 100-A 2-PP-3.2 LEVEL 8 PLUMBING ENLARGED PLAN - AREA 200-A 2-EP-1.1C LEVEL 8 - POWER PLAN - SUITE 200 2-AI-2.3 LEVEL 8 ENLARGED FLOOR PLAN- AREA 300 2-PP-3.3 LEVEL 8 PLUMBING ENLARGED PLAN - AREA 300 2-EP-2.1A LEVEL 8 - ROOF POWER PLAN 2-AI-2.4 LEVEL 8 REFERENCE FLOOR PLAN- AREA 200-A 2-PP-3.4 LEVEL 8 PLUMBING ENLARGED PLAN - AREAS 100-B & 200-B 2-EP-2.1B - LEVEL 8 - ROOF POWER PLAN - SUITE 100 2-AI-2.5 LEVEL 8 ENLARDGED FLOOR PLAN - AREA 100B & 200-B 2-PP-3.5 LEVEL 7 OVERALL PLUMBING PLAN 2-EP-2.1C - LEVEL 8 - ROOF POWER PLAN - SUITE 200 2-AI-2.6 LEVEL 8 ENLARGED DEMOLITION PLAN 2-PP-3.6 LEVEL 7 PLUMBING ENLARGED PLAN - AREA 100-A 2-EP-3.1 - LEVEL 9 - PARTAIL ROOF POWER PLAN 2-AI-2.7 LEVEL 9 REFERENCE FLOOR PLAN 2-PP-3.7 LEVEL 7 PLUMBING ENLARGED PLAN - AREA 300 2-EP-4.1 - LEVEL 8 - ENLARGED MECHANICAL ROOM POWER FLOORPLAN 2-AI-2.7A EQUIPMENT PLAN - AREA 100/200 2-PP-3.8 LEVEL 7 PLUMBING ENLARGED PLAN - AREA 200-A 2-EP-6-0 ELECTRICAL SCHEDULES 2-AI-2.7B EQUIPMENT LIST - AREA 100/200 2-PP-3.9 LEVEL 7 PLUMBING ENLARGED PLAN - AREA 100-B & 200-B 2-EP-6-1 ELECTRICAL SCHEDULES A-AI-2.8 PATIENT LIFT COORDINATION 2-PP-5.1 PLUMBING SCHEDULES 2-EP-6-2 ELECTRICAL SCHEDULES

2-AI-2.9 FINISH PLAN 2-PP-6.1 PLUMBING DETAILS 2-EP-6-3 ELECTRICAL SCHEDULES

2-AI-3.1 DOOR SCHEDULE, DOOR TYPES, & FRAME TYPES 2-PP-7.1 OVERALL SANITARY RISER 2-EP-6-4 ELECTRICAL SCHEDULES 2-AI-4.1 STANDARD PARTITION TYPES 2-PP-7.2 OVERALL PLUMBING RISER- PRESSURE PIPING 2-EP-6-5 ELECTRICAL SCHEDULES 2-AI-4.3 MILLWORK DETAILS 2-PP-7.3 PLUMBING RISER - 100 A & B 2-EP-6-6 ELECTRICAL SCHEDULES 2-AI-4.4 INTERIOR ELEVATIONS 2-PP-7.4 PLUMBING RISER - AREA 200-A & B 2-EP-6-7 ELECTRICAL SCHEDULES 2-AI-4.5 PLUMBING DIAGRAMS / ACCESSORIES / MOUNTING HEIGHTS 2-PP-7.5 PLUMBING RISER - AREA 300 2-E-5.1 ELECTRICAL LIGHTING DETAILS

2-AI-5.1 REFLECTED CEILING PLAN 2-E-5.1 ELECTRICAL LIGHTING DETAILS

2-AI-7.0 AXONOMETRIC 2-E-5.2 ELECTRICAL LIGHTING DETAILS

2-M-0.1 MECHANICAL GENERAL NOTES & ABBREVIATIONS 2-E-5.2 ELECTRICAL LIGHTING DETAILS

2-MD-1.1 LEVEL 8 - MECHANICAL DEMO FLOORPLAN 2-E-601 ELECTRICAL RISER DIAGRAM A

2-S-1.1 STRUCTURAL NOTES 2-MH-0.2 AIR BALANCE ANALYSIS 2-E-602 ELECTRICAL RISER DIAGRAM B 2-S-2.1 LEVEL 8 & 9 PARTIAL PLANS 2-MH-1.1 LEVEL 8 - ENLARGED MECHANICAL FLOORPLAN 2-E-603 ELECTRICAL GROUNDING DIAGRAM

2-MH-1.1A LEVEL 8 - MECHANICAL PLAN - SUITE 100 2-E-604 ELECTRICAL REVISED RISER DIAGRAM A 2-MH-1.1B LEVEL 8 - MECHANICAL PLAN - SUITE 300 2-E-605 ELECTRICAL REVISED RISER DIAGRAM B

2-FA-1.1 FIRE ALARM GENERAL NOTES 2-MH-1.1C LEVEL 8 - MECHANICAL PLAN - SUITE 200 2-EL-1-1 LEVEL 8 - ENLARGED ELECTRICAL LIGHTING PLAN 2-FA-2.1 FIRE ALARM PLAN 2.MH.1.1D ENLARGED MECHANICAL ROOM PLAN 2-EL-6.0 LUMINAIRE SCHEDULE 2-FP-1.1 FIRE PROTECTION GENERAL NOTES 2-MH-1.4 LEVEL 8 MECHANICAL ROOF PLAN SUITES 100 AND 200 2-ET-1-1 LEVEL 8 - ENLARGED TELECOM FLOORPLAN-LATEST 2-FP-2.1 FIRE PROTECTION PLAN 2-MH-1.5 LEVEL 9 MECHANICAL ROOF PLAN 2-ET-1.1 LEVEL 8 - ENLARGED TELECOM PLAN

2-MH-3.1 SUITE 100 HVAC SECTIONS 2-ET-1.1A LEVEL 8 -TELECOM SUITE 100 PLAN

2-MH-3.2 SUITE 200 HVAC SECTIONS 2-ET-1.1B LEVEL 8 -TELECOM SUITE 300 PLAN

2-MH-3.3 SUITE 300 HVAC SECTIONS 2-ET-1.1C LEVEL 8 -TELECOM SUITE 200 PLAN

2-MH-6.1 AHU-8 ISOLATED AIRFLOW SCHEMATIC

2-MH-6.2 HVAC SCHEDULE

2-MH-6.3 CONTROL DIAGRAMS AND SEQUENCES

2-MH-6.4 EQUIPMENT AND DUCTWORK DETAILS

2-MH-6.5 DUCTWORK AND EQUIPMENT SUPPORT DETAILS

2-MH-6.6 PIPE DETAILS

2-MH-6.7 PIPING SCHEMATICS

2-MP-1.1 LEVEL 8 - MECHANICAL PIPING PLAN

2-MP-1.1A LEVEL 8 - MECHANICAL HYDRONICS - SUITE 100

2-MP-1.1B LEVEL 8 - MECHANICAL HYDRONICS - SUITE 200

2-MP-1.1C LEVEL 8 - MECHANICAL HYDRONICS - SUITE 300

PLUMBING SHEETS

MECHANICAL SHEETS

SHEET INDEX

ELECTRICAL SHEETS

SHEET INDEX

GENERAL SHEETS

SHEET INDEX

ARCHITECTURAL SHEETS

STRUCTURAL SHEETS

FIRE ALARM / PROTECTION SHEETS

SHEET

NUMBER

SHEET NAME

SHEET

NUMBER

SHEET NAME

SHEET

NUMBER

SHEET NAME

2-GI-1.0 COVER SHEET 2-FA-1.1 FIRE ALARM GENERAL NOTES 2-MH-0.1 GENERAL NOTES & SHEET INDEX 2-GI-1.0A SHEET INDEX 2-FA-2.1 FIRE ALARM PLAN 2-MH-0.2 GENERAL NOTES & ABBREVIATIONS 2-GI-1.1 GENERAL INFORMATION 2-FP-1.1 FIRE PROTECTION GENERAL NOTES 2-MH-0.3 LEGENDS 2-GI-1.2 LIFE SAFETY DATA/PLAN 2-FP-2.1 FIRE PROTECTION PLAN 2-MD-1.1 LEVEL 8 - MECHANICAL DEMO FLOORPLAN

2-GI-1.3 SITE & PHASING PLAN 2-MH-1.0 AIR BALANCE ANALYSIS

2-MH-1.1 LEVEL 8 - ENLARGED MECHANICAL FLOORPLAN

2-PD-2.1 PLUMBING DEMOLITION PLAN 2-MH-1.1A LEVEL 8 - MECHANICAL PLAN - SUITE 100

2-AI-2.0 LEVEL 7 REFERENCE FLOOR PLAN 2-PG-2.1 LEVEL 8 MEDICAL GAS PIPING OVERALL PLAN 2-MH-1.1B LEVEL 8 - MECHANICAL PLAN - SUITE 200 2-AI-2.1 LEVEL 8 OVERALL FLOOR PLAN 2-PG-2.2 LEVEL 8 MEDICAL GAS PIPING PLAN - AREA 100-A 2-MH-1.1C LEVEL 8 - MECHANICAL PLAN - SUITE 300 2-AI-2.2 LEVEL 8 ENLARGED FLOOR PLAN- AREA 100-A 2-PG-2.3 LEVEL 8 MEDICAL GAS PIPING PLAN - AREA 300 2.MH.1.1D ENLARGED MECHANICAL ROOM PLAN 2-AI-2.3 LEVEL 8 ENLARGED FLOOR PLAN- AREA 300 2-PG-2.4 LEVEL 8 MEDICAL GAS PIPING PLAN - AREA 200-A 2-MH-1.4 LEVEL 8 MECHANICAL ROOF PLAN SUITES 100 AND 200 2-AI-2.4 LEVEL 8 REFERENCE FLOOR PLAN- AREA 200-A 2-PG-2.5 LEVEL 8 MEDICAL GAS PIPING PLAN - AREAS 100-B & 200-B 2-MH-1.5 LEVEL 9 MECHANICAL ROOF PLAN 2-AI-2.5 LEVEL 8 ENLARDGED FLOOR PLAN - AREA 100B & 200-B 2-PG-7.0 OVERALL MEDICAL GAS RISER 2-MH-3.1 SUITE 100 HVAC SECTIONS 2-AI-2.6 LEVEL 8 ENLARGED DEMOLITION PLAN 2-PP-0.1 PLUMBING ABBREVIATIONS AND GENERAL NOTES 2-MH-3.2 SUITE 200 HVAC SECTIONS 2-AI-2.7 LEVEL 9 REFERENCE FLOOR PLAN & LEVEL 8 ROOF 2-PP-3.0 LEVEL 8 OVERALL PLUMBING PLAN 2-MH-3.3 SUITE 300 HVAC SECTIONS 2-AI-2.7A EQUIPMENT PLAN - AREA 100/200 2-PP-3.1 LEVEL 8 PLUMBING ENLARGED PLAN - AREA 100-A 2-MH-6.1 AHU-8 ISOLATED AIRFLOW SCHEMATIC 2-AI-2.7B EQUIPMENT PLAN - AREA 300 & EQ LIST (ALL AREAS) 2-PP-3.2 LEVEL 8 PLUMBING ENLARGED PLAN - AREA 200-A 2-MP-1.1 LEVEL 8 - MECHANICAL PIPING PLAN A-AI-2.8 PATIENT LIFT COORDINATION 2-PP-3.3 LEVEL 8 PLUMBING ENLARGED PLAN - AREA 300 2-MP-1.1A LEVEL 8 - MECHANICAL HYDRONICS - SUITE 100 2-AI-2.9 FINISH PLAN 2-PP-3.4 LEVEL 8 PLUMBING ENLARGED PLAN - AREAS 100-B & 200-B 2-MP-1.1B LEVEL 8 - MECHANICAL HYDRONICS - SUITE 200 2-AI-3.1 DOOR SCHEDULE, DOOR TYPES, & FRAME TYPES 2-PP-3.5 LEVEL 7 OVERALL PLUMBING PLAN 2-MP-1.1C LEVEL 8 - MECHANICAL HYDRONICS - SUITE 300 2-AI-4.1 STANDARD PARTITION TYPES & NOTES 2-PP-3.6 LEVEL 7 PLUMBING ENLARGED PLAN - AREA 100-A 2-MH-6.2 HVAC SCHEDULES 2-AI-4.3 MILLWORK DETAILS 2-PP-3.7 LEVEL 7 PLUMBING ENLARGED PLAN - AREA 300 2-MH-6.3 CONTROL DIAGRAMS AND SEQUENCES 2-AI-4.4 INTERIOR ELEVATIONS 2-PP-3.8 LEVEL 7 PLUMBING ENLARGED PLAN - AREA 200-A 2-MH-6.4 EQUIPMENT AND DUCTWORK DETAILS 2-AI-4.5 PLUMBING DIAGRAMS / ACCESSORIES / MOUNTING HEIGHTS 2-PP-3.9 LEVEL 7 PLUMBING ENLARGED PLAN - AREA 100-B & 200-B 2-MH-6.5 DUCTWORK AND EQUIPMENT SUPPORT DETAILS 2-AI-5.1 REFLECTED CEILING PLAN 2-PP-5.1 PLUMBING SCHEDULES 2-MH-6.6 PIPE DETAILS

2-AI-7.0 AXONOMETRIC 2-PP-6.1 PLUMBING DETAILS 2-MH-6.7 PIPING SCHEMATICS

2-PP-7.1 OVERALL SANITARY RISER

2-PP-7.2 OVERALL PLUMBING RISER- PRESSURE PIPING

2-S-1.1 STRUCTURAL NOTES 2-PP-7.3 PLUMBING RISER - 100 A & B 2-E-1.0 COVER SHEET - GENERAL NOTES AND SHEET INDEX 2-S-2.1 LEVEL 8 & 9 PARTIAL PLANS 2-PP-7.4 PLUMBING RISER - AREA 200-A & B 2-E-1.1 GENERAL NOTES

2-PP-7.5 PLUMBING RISER - AREA 300 2-E-1.2 GENERAL NOTES, SYMBOLS AND ABBREVIATIONS

2-ED-1.1 LEVEL 8 - ENLARGED DEMO / AUX FLOORPLAN

2-EL-1.1 LEVEL 8 - ENLARGED ELECTRICAL LIGHTING FLOORPLAN

2-EP-1.1 LEVEL 8 - ENLARGED ELECTRICAL POWER FLOORPLAN

2-EP-1.1A LEVEL 8 - POWER PLAN - SUITE 100

2-EP-1.1B LEVEL 8 - POWER PLAN - SUITE 200

2-EP-1.1C LEVEL 8 - POWER PLAN - SUITE 300

2-EP-1.2 LEVEL 8 - ENLARGED MECHANICAL POWER FLOOR PLAN

2-EP-1.2A LEVEL 8 - MECHANICAL POWER PLAN - SUITE 100

2-EP-1.2B LEVEL 8 - MECHANICAL POWER PLAN - SUITE 200

2-EP-1.2C LEVEL 8 - MECHANICAL POWER PLAN - SUITE 300

2-EP-2.1A LEVEL 8 - MECHANICAL ROOF PLAN

2-EP-6.0 PANEL SCHEDULES

2-EP-6.1 PANEL SCHEDULES

2-EP-6.2 PANEL SCHEDULES

2-EP-6.3 PANEL SCHEDULES

2-EP-6.4 ELECTRICAL GROUNDING DIAGRAM

2-EP-6.5 ELECTRICAL REVISED RISER

2-ET-1.1 LEVEL 8 - ENLARGED TELECOM FLOOR PLAN

2-ET-1.1A LEVEL 8 - TELECOM - SUITE 100

2-ET-1.1B LEVEL 8 - TELECOM - SUITE 300

2-ET-1.1C LEVEL 8 - TELECOM - SUITE 200

MECHANICAL SHEETS

ELECTRICAL SHEETS

PLUMBING SHEETS

FIRE ALARM / PROTECTION SHEETSGENERAL SHEETS

ARCHITECTURAL SHEETS

STRUCTURAL SHEETS

0 COLUMN GRID LINE

DOOR NUMBER

SYMBOL

DETAIL - SECTION

POSITION ON SHEET

SHEET NUMBER

DETAIL - PLAN/ RCP

POSITION ON SHEET

SHEET NUMBER

WALL SECTION

POSITION ON SHEET

SHEET NUMBER

EXTERIOR ELEVATION

POSITION ON SHEET

SHEET NUMBER

INTERIOR ELEVATION

POSITION ON SHEET

SHEET NUMBER

EXTERIOR WALL TYPE TAG

EXTERIOR WINDOW

SIGN TYPE, SEE SIGNAGE

SCHEDULE

DRAWING NUMBER

DRAWING SCALE

VIEW TITLE

NOTES BY NUMBER

DRAWING REVISION

LEVEL DATUM

LEVEL NAME

LEVEL ELEVATION

NORTH ARROW

INTERIOR WINDOW

GRAPHIC SCALE

0 4'-0" 8'-0" 16'-0"

-G D

XX

XX

XXXX

7'-0" R 3'-11"

100°

SIM

X

X-XXX

DIMENSION TO FACE OF FINISH,

FACE OF CONCRETE, COLUMN

CENTERLINE, OR AS NOTED.

CENTERLINE

X

X X

X

A1

A101

SIM

A101

SIM

ROOM TAG (FOR SPECIALTY PLANS)

ROOM NAME

ROOM NUMBER

FLOOR FINISH

ROOM NAME

XXXX

FLOR

BASE

WALL

CEIL BASE TYPE

WALL FINISH

CEILING TYPE

A

A101

SIM

/1 2-AI-2.0

DRAWING REFERENCE SYSTEM

SHEET NUMBER

DRAWING NUMBER

Name Elevation

1/8" = 1'-0"

AC1

NORTH

INTERIOR PARTITION TYPE TAGA3

ROOM NAME

150 SF

ROOM NAME

150 SF

ROOM NAME

ROOM NUMBER

ROOM AREA

INSULATION (IF NEEDED)

ROOM TAG (FOR STANDARD PLANS)

BATT. INSULATION

CAST IN PLACE CONCRETE

CAST STONE

CONCRETE MASONRY/CMU

EARTH IN SECTION

FACE BRICK

GYP./GYPSUM BOARD

MARBLE

PARTICLE BOARD/PLYWOOD

ROOF INSULATION

STUCCO

CONTINUOUS WOOD BLOCKING

DISCONTINUOUS WOOD BLOCKING

FINISHED WOOD

GENERAL PROJECT DESCRIPTION

THIS PROJECT SHALL CONSIST OF INTERIOR RENOVATIONS TO AN EXISTING BUILDING AS DEFINED ON

THE CHART BELOW.

PROJECT TYPE YES NO

NEW CONSTRUCTION: (COMPLETELY NEW BUILDING AND SITE WORK)

ADDITION: (NEW CONSTRUCTION TO INCREASE SIZE OF EXISTING BUILDING)

RENOVATION: (REPLACEMENT OF EXISTING BUILDING COMPONENTS)

SYSTEM UPGRADES

ITEM YES NO

NEW STRUCTURAL SYSTEM

EXISTING STRUCTURAL SYSTEM AFFECTED

EXISTING EXTERIOR WALLS AFFECTED

EXTERIOR WALLS

EXISTING INTERIOR WALLS AFFECTED

EXISTING INTERIOR FINISHES AFFECTED

EXISTING ROOFING AFFECTED:

HVAC SYSTEMS AFFECTED:

ELECTRICAL SYSTEMS AFFECTED:

IT/ COMMS

1) CAT 6A CABLE TO BE INSTALLED

EQUIPMENT PLAN GENERAL NOTES

A. COORDINATE ALL EQUIPMENT MOUNTING HEIGHTS AND LOCATIONS WITH ARCHITECT, PRIOR TO INSTALLATION.

B. ITEMS SHOWN BLACK ARE PROVIDED BY CONTRACTOR AS PART OF THIS CONTRACT.

C. INCLUDE SURGE PROTECTION FOR ALL EQUIPMENT.

D. ALL EQUIPMENT SHOWN ON PLANS ARE GENERIC AND REPRESENTATIONAL FOR COORDINATION PURPOSES ONLY.

E. POWER, DATA, AND MED GAS LOCATIONS ARE GENERALLY SHOWN ON ARCHITECTURAL AND/OR MEP DRAWINGS. THE CONTRACTORS

SHALL COORDINATE AND PROVIDE ALL CONNECTIONS REQUIRED FOR ALL EQUIPMENT SCHEDULED AND SHOWN.

F. FOR ALL EQUIPMENT SCHEDULED TO BE OWNER FURNISHED - CONTRACTOR INSTALLED, THE CONTRACTOR SHALL COORDINATE WITH

THE OWNER AS REQUIRED TO RECIEVE AND INSTALL THE EQUIPMENT.

G. FOR EQUIPMENT SCHEDULED TO BE OWNER FURNISHED - OWNER INSTALLED, OR VENDOR FURNISHED - VENDOR INSTALLED, THE

CONTRACTOR SHALL COORDINATE WITH THE OWNER AND VENDOR AS REQUIRED TO ALLOW THE EQUIPMENT TO BE INSTALLED

PROPERLY. PROVIDE UTILITY CONNECTIONS AS REQUIRED.

H. FOR EQUIPMENT SCHEDULED TO BE CONTRACTOR FURNISHED - CONTRACTOR INSTALLED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL ASPECTS OF EQUIPMENT RECIEVING, INSTALLATION, AND UTILITY CONNECTION.

I. EQUIPMENT LIST CAN BE FOUND ON SHEET 2-AI-2.7B.

J. PROVIDE HEADWALLS AT ALL LOCATIONS SHOWN ON PLAN. FOR ADDITIONAL INFORMATION, SEE SHEET 2-AI-4.4

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: MR. ALEX MULLER-POITEVIEN, COR

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Architecture THESE DOCUMENTS

ARE FOR INTERIM

REVIEW AND ARE NOT

INTENDED FOR

CONSTRUCTION,

BIDDING, OR PERMIT

PURPOSES.

LBL Architects

1106 W. Randol Mill Rd, Suite 300

Arlington, TX 76012

817-265-1510 www.lblarchitects.com

OEI-LBL Joint Venture LLC

O'Brien Engineering, Inc., Managing Partner

Carrollton, TX 75006

972-233-2288

2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com

THOMAS R. MCCARTY

TEXAS ARCHITECT #20587

B

IM

/V

A D

A

T H

F L

O O

R /5

-2

-2

-A

-R

.r v t

/1 /2

:5

:0

A

M

2-GI-1.1

GENERAL INFORMATION RENOVATE MEDICAL INPATIENT

UNIT FOR PATIENT PRIVACY &

COVID-19

DALLAS, TEXAS

549-20-222

11/04/2022 TM TT

11/04/2022

ISSUE FOR BID

DRAWING LEGENDABBREVIATIONS

ACT. ACTUAL

ADJ. ADJUSTABLE

A.F.F. ABOVE FINISH FLOOR

A.F.S. ABOVE FINISH SLAB

AGG. AGGREGATE

AHJ AUTHORITY HAVING JURISDICTION

ALUM. ALUMINUM

BLDG. BUILDING

BK. BRICK

BM. BEAM

CAB. CABINET

CPT. CARPET

C.J. CONTROL JOINT

CENTERLINE

CG CORNER GUARD

CLG. CEILING

COL. COLUMN

CONC. CONCRETE

COND. CONDITION

CONT. CONTINUOUS

C.T. COUNTERTOP

DBL. DOUBLE

DEMO. DEMOLITION

DIA. DIAMETER

DIM. DIMENSION

DISP. DISPENSER

DN. DOWN

DWG. DRAWING

E.W.C. ELECTRIC WATER COOLER

EA. EACH

E.J. EXPANSION JOINT

EXP. EXPANSION

E.W. EACH WAY

EXT. EXTERIOR

EXIST. EXISTING

F.E.C. FIRE EXTINGUISHER CABINET

F.D. FINISH DIMENSION

F.D.V.B. FIRE DEPARTMENT VALVE BOX

F.F. FINISH FLOOR

FIN. FINISH(ED)

FRT. FIRE RETARDANT TREATED

G.I. GALVANIZED IRON

G.B./GYP.BD. GYPSUM BOARD

GA. GAUGE

GALV. GALVANIZED

GL. GLASS

H.M. HOLLOW METAL

H.S. HORIZONTAL IN SPLASH

I.C.U. INTENSIVE CARE UNIT

INT. INTERIOR

INSUL. INSULATION

I.T.C. INSTALLED THIS CONTRACT

K.S. KNEE SPACE

LAM. LAMINATED

LAV. LAVATORY

L.L.V. LONG LEG VERTICAL

L.L.H. LONG LEG HORIZONTAL

MANUF. MANUFACTURER

MAX. MAXIMUM

MECH. MECHANICAL

MIN. MINIMUM

M.O. MASONRY OPENING

MTL./MET. METAL

MNT. MOUNTED

N/A NOT APPLICABLE

NOM. NOMINAL

N.T.S. NOT TO SCALE

N.I.C. NOT IN CONTRACT

O.C. ON CENTER

O.D. OVERFLOW DRAIN

O.H/OPP.H. OPPOSITE HAND

P.D. PLAN DIMENSION

PLAS. LAM. PLASTIC LAMINATE

P.T. PORCELAIN TILE

P.T.D. PAPER TOWEL DISPENSER

RB RUBBER BASE

R./REV. REVISED/REVERSE

R./RAD. RADIUS

REINF. REINFORCE

REF. REFERENCE/REFER TO

REQ'D REQUIRED

R.D. ROOF DRAIN

RM. ROOM

R.O. ROUGH OPENING

SCHED. SCHEDULED

SAB. SOUND ATTENUATION BATTS

SHT. SHEET

SIM. SIMILAR

SL. SLOPE

STL. STEEL

S.S. STAINLESS STEEL

S.S.V. SOLID SURFACE VENEER

SUSP. SUSPENDED

S.V. SHEET VINYL

T.A.S. TEXAS ACCESSIBILITY STANDARDS

T.B. TACK BOARD

T.D.H. TEXAS DEPARTMENT OF HEALTH

TEMP. OR (T.) TEMPERED GLASS

THK. THICK

TOIL. TOILET

TYP. TYPICAL

U.C. UNDER COUNTER

UCR UNDER COUNTER REFRIGERATOR

U.L. UNDERWRITERS LABORATORIES

U.N.O. UNLESS NOTED OTHERWISE

UR. NEW URINAL

V.I.F. VERIFY IN FIELD

VCT VINYL COMPOSITION TILE

V.T. VINYL TILE

VERT. VERTICAL

W.C. NEW WATER CLOSET

WDW. WINDOW

WD. WOOD

WH WATER HEATER

W/ WITH

W/O WITHOUT

MATERIALS LEGEND

Revisions: Date:

Dallas VA 8th Floor

SP SP SP SP SP

S S S S S

UP

S S

S

S

S

S S

S

SS

S S

S S

S

SS

S S

S

S S S

S S S

S S

S

S

S S S S S S S

S

S

S S S

S S

S

S

S S

S

S S

S S S

S S

S

S

S S

S

S S

S

S S

S S

S S

S S

S

SS

S S

S S S

S S

SS

S S

S

SS

S

S

S

S

S

S

LIFE SAFETY SYMBOLS

XX PATH OF TRAVEL

(FOR CUMULATIVE DISTANCES

REFER TO SCHEDULE)

FIRE EXTINGUISHER AND RECESSED CABINET

FIRE EXTINGUISHER ON WALL BRACKET

FEC

FE

LIFE SAFETY PLANS GENERAL NOTES

A. ALL AREAS TO BE REMODELED ARE PROTECTED BY AUTOMATIC FIRE

SPRINKLER SYSTEM IN COMPLIANCE WITH N.F.P.A. THE EXISTING SYSTEM

SHALL BE MODIFIED TO FIT NEW WALL LAYOUT AS REQUIRED TO COMPLY

WITH CODE.

B. LIFE SAFETY GENERAL NOTES

a. ALL PENETRATIONS MADE THROUGH RATED WALLS SHALL BE

CONSTRUCTED AND SEALED AS REQUIRED TO MAINTAIN THE

REQUIRED WALL RATING.

b. ALL DOORS, OPENINGS, AND RECESSED ACCESSORIES IN RATED

PARTITIONS SHALL BE CONSTRUCTED AND SEALED AS REQUIRED TO

MAINTAIN THE REQUIRED WALL RATING.

c. CORRIDOR ENCLOSURE WALLS AND CEILING SHALL BE

CONSTRUCTED AND SEALED TO RESIST THE PASSAGE OF SMOKE.

d. HIGHER RATED FIRE WALLS TAKE PRECEDENCE OVER LOWER RATED

WALLS & ARE TO CONTINUE THROUGH ALL SUCH INTERSECTIONS.

e. LOCATE FIRE EXTINGUISHER CABINETS 1’-8” FROM ANY ABUTTING

WALL, DOOR FRAME OR EDGE OF DOOR IN OPEN POSITION, UNLESS

NOTED OTHERWISE.

f. ALL SMOKE DETECTORS, HORNS, STROBES, EGRESS LIGHTING AND

OTHER LIFE SAFETY DEVICES SHALL BE HARDWIRED WITH BATTERY

BACKUP.

C. BUILDING CODE GENERAL NOTES

a. FOR INTERIOR RENOVATION PROJECTS:

1. BUILDING ENVELOPE IS EXISTING TO REMAIN. ANY

PENETRATIONS THAT ARE CREATED OR FILLED IN SHALL

MEET OR EXCEED ALL CURRENT APPLICABLE CODE

REQUIREMENTS.

b. EXTERIOR ENVELOPE, INCLUDING ALL FLOORS, WALLS, ROOF AREAS, OPENINGS, ETC. SHALL BE CONSTRUCTED TO MEET OR EXCEED ALL

APPLICABLE CODES AND REGULATIONS.

SMOKE BARRIER

NOTE: SOME SMOKE BARRIERS ARE FIRE RATED. SEE

FIRE RATED PARTITIONS IN THIS LEGEND.

SMOKE PARTITION

ONE HOUR FIRE RATED PARTITION

NOTE: SOME FIRE PARTITIONS ARE SMOKE BARRIERS. SEE

SMOKE BARRIERS IN THIS LEGEND.

TWO HOUR FIRE RATED PARTITION

NOTE: SOME FIRE PARTITIONS ARE SMOKE BARRIERS. SEE

SMOKE BARRIERS IN THIS LEGEND.

THREE HOUR FIRE RATED PARTITION

NOTE: SOME FIRE PARTITIONS ARE SMOKE BARRIERS. SEE

SMOKE BARRIERS IN THIS LEGEND.

NO ANTICIPATED WORK IN THIS AREA EXCEPT

AS REQUIRED BY THAT IN ADJACENT AREAS.

AREA TO REMAIN IN OPERATION

THROUGHOUT PROJECT DURATION.

CODE INFORMATION

BUILDING: 2018 INTERNATIONAL BUILDING CODE

ACCESSIBILITY: TEXAS ACCESSIBILITY STANDARDS 2012 EDITION

FIRE: 2018 INTERNATIONAL FIRE CODE

2018 NFPA 101

PLUMBING: 2018 INTERNATIONAL PLUMBING CODE

MECHANICAL: 2018 INTERNATIONAL MECHANICAL CODE

ELECTRICAL: 2017 NATIONAL ELECTRICAL CODE

ENERGY: 2018 INTERNATIONAL ENERGY CODE

2019 ASHRAE 90.1

OCCUPANCY CLASSIFICATIONS

GROUP I-2 - INSTITUTIONAL

CONSTRUCTION TYPE

TYPE I-B CONSTRUCTION (IBC 602.2) - NON COMBUSTIBLE CONCRETE FRAME AND DECKS

LIFE SAFETY: NFPA 101 LIFE SAFETY CODE 2012

TYPE I-332 (TABLE A.8.2.1.2) - NFPA 101 LIFE SAFETY CODE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

TOILET

WAITING

8C-309

348 SF TELECAR

ROOM

8C-308

124 SF

ELECTRICAL

8C-307

93 SF

TLT

8C-306

59 SF

COMMUNICATIONS

8C-303

156 SF

MECHANICAL

8C-302

1,185 SF

FAMILY

CONSULTATION/

EDUCATION

8C-311

186 SF

VERTICAL

CIRCULATION

PASS. ELEV.

P3

STAIRWELL - 2

STAIRWELL - 1

STAIRWELL - 5

8A 8B

8D

8C

8E

FE

FE

FEC

FECFEC

FEC

FEC FEC

FEC

8F8G8H

TLT

8C-305

59 SF

NURSE

MANAGER

8C-236

91 SF

NURSE

STATION

8C-235

230 SF

LOCKER

8C-202

104 SF

TLT

8C-204

51 SF

TLT

8C-203

51 SF

STAFF

LOUNGE

8C-205

166 SF

ELEVATOR

LOBBY

8C-300

174 SF

MEDICATION

8C-206

102 SF

CLEAN

UTILITY

8C-207

115 SF

ELECTRICAL

8C-208

131 SF

ISO

BARIATRIC

PATIENT

RM

8C-210

289 SF

PATIENT

RM

8C-220

249 SF

SOILED

HOLDING

8C-222

124 SF

JAN

8C-223

70 SF

NOURISHMENT

8C-224

107 SF

ISO

PATIENT

RM

8C-226

279 SF

TLT/SHWR

8C-227

79 SF

TLT/SHWR

8C-221

71 SF

PATIENT

RM

8C-218

256 SF

TLT/SHWR

8C-219

73 SF

TLT/SHWR

8C-217

70 SF

PATIENT

RM

8C-216

247 SF

PATIENT

RM

8C-214

247 SF

TLT/SHWR

8C-215

70 SF

MEDICAL

EQUIPMENT

8C-213

142 SF

CLEAN

LINEN

8C-212

62 SF

TLT/SHWR

8C-211

84 SF

ISO

PATIENT

RM

8C-229

280 SF

TLT/SHWR

8C-230

79 SF

ISO

PATIENT

RM

8C-232

300 SFTLT/SHWR

8C-233

81 SFMEDICAL

EQUIPMENT

8C-234

99 SF

PATIENT

RM

8C-123

247 SF

TLT/SHWR

8C-124

71 SF

MEDICAL

EQUIPMENT

8C-125

142 SF

TLT/SHWR

8C-129

84 SF

ISO

BARIATRIC

PATIENT

RM

8C-128

289 SF

CLEAN

LINEN

8C-126

66 SF

PATIENT

RM

8C-119

256 SF

TLT/SHWR

8C-120

73 SF

TLT/SHWR

8C-122

69 SF

PATIENT

RM

8C-121

247 SF

TLT/SHWR

8C-118

71 SF

PATIENT

RM

8C-117

249 SF

SOILED

HOLDING

8C-116

124 SF

JAN

8C-115

70 SF

NOURISHMENT

8C-114

107 SF

ELECTRICAL

8C-130

127 SF

CLEAN

UTILITY

8C-131

114 SF

MEDICATION

8C-132

103 SF

STAFF

LOUNGE

8C-133

173 SF

TLT

8C-135

51 SF

TLT

8C-136

51 SF

LOCKER

8C-134

101 SF

NURSE

STATION

8C-102

226 SF

NURSE

MANAGER

8C-103

91 SF

ISO

PATIENT

RM

8C-112

279 SF

TLT/SHWR

8C-113

79 SF

ISO

PATIENT

RM

8C-109

280 SF

ANTE

8C-108

80 SF

TLT/SHWR

8C-110

79 SF

ISO

PATIENT

RM

8C-106

303 SF

ANTE

8C-105

79 SF

TLT/SHWR

8C-107

81 SF MEDICAL

EQUIPMENT

8C-104

99 SF

SC-100

SC-300

SC-200

OCCUPANCY REQUIRED NUMBER

OF EXTINGUISHERS

OCCUPANCY

OCCUPANT LOAD

SERVED BY

CORRIDOR

FIRE RESISTANCE-RATING

(WITH SPRINKLER SYSTEM)

REQUIRED PROVIDED

PROVIDED NUMBER OF

EXTINGUISHERS

IBC I-2 7

IBC I-2 ALL 0-HOUR

(IBC TABLE 1018.1) (LIFE SAFETY CODE A.38.3.6.1, (3))

0-HOUR

AUTOMATIC SPRINKLER SYSTEM (IBC 903): YES (TIE INTO EXISTING)

STANDPIPE SYSTEM (IBC 905, NFPA 14): N/A

PORTABLE FIRE EXTINGUISHERS (IBC 906, NFPA 10): SEE BELOW

FIRE ALARM SYSTEM (IBC 907): YES (TIE INTO EXISTING, REQUIRED)

SMOKE CONTROL SYSTEM (IBC 909): N/A

NFPA HEALTH CARE ALL 0-HOUR 0-HOUR

CORRIDOR FIRE RESISTANCE

RATING

FIRE PROTECTION SYSTEMS SUMMARY

SMOKE COMPARTMENTS

ADJACENT COMPARTMENT

MAX TRAVEL DISTANCE TO

AREACOMPARTMENT

NFPA HEALTH CARE 7

OCCUPANCY

CLASSIFICATION

MAXIMUM

DEAD-END

DISTANCE

COMMON PATH

OF EGRESS TRAVEL

EXIT ACCESS

TRAVEL DISTANCE

TO SMOKE

COMPARTMENT OR

EXIT

MOST STRINGENT REQUIREMENTS OF: (IBC TABLE 1017.2) (LIFE SAFETY

CODE TABLE A.7.6)

200'-0" 20'-0" 75'-0"

NUMBER OF EXITS (IBC 1006):

ACCESS TO 2 EXITS ARE REQUIRED FROM ANY SPACE OF THE BUILDING

A MINIMUM OF 2 EXITS ARE PROVIDED.

NFPA

HEALTH CARE

EXITS AND ARRANGEMENT

MEANS OF EGRESS REQUIREMENTS

200'-0" 20'-0" 75'-0"IBC I-2

75'-0"MAXIMUM TRAVEL OF DISTANCE TO EXTINGUISHER:

7,144 SFSC-100

7,287 SFSC-200

2004,308 SFSC-300

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: MR. ALEX MULLER-POITEVIEN, COR

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Architecture THESE DOCUMENTS

ARE FOR INTERIM

REVIEW AND ARE NOT

INTENDED FOR

CONSTRUCTION,

BIDDING, OR PERMIT

PURPOSES.

LBL Architects

1106 W. Randol Mill Rd, Suite 300

Arlington, TX 76012

817-265-1510 www.lblarchitects.com

OEI-LBL Joint Venture LLC

O'Brien Engineering, Inc., Managing Partner

Carrollton, TX 75006

972-233-2288

2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com

THOMAS R. MCCARTY

TEXAS ARCHITECT #20587

B

IM

/V

A D

A

T H

F L

O O

R /5

-2

-2

-A

-R

.r v t

/1 /2

:5

:1

A

M

2-GI-1.2

LIFE SAFETY DATA/PLAN RENOVATE MEDICAL INPATIENT

UNIT FOR PATIENT PRIVACY &

COVID-19

DALLAS, TEXAS

549-20-222

11/04/2022 TM TWS

11/04/2022

ISSUE FOR BID

TRAVEL DISTANCE SCHEDULE

PATH

NAME DISTANCE

8A 113'

8B 144'

8C 133'

8D 89'

8E 151'

8F 113'

8G 144'

8H 169'

3/32" = 1'-0"

LEVEL 8 LIFE SAFETY PLAN

Revisions: Date:

UP

2J

PROJECT AREA

CONTRACTOR BLDG

ACCESS. SERVICE

ELEVATORS TO BE

UTILIZED FOR

ACCESS TO

PROJECT SITE

FREEDOM

GARAGE

LIBERTY

PARKING

GARAGE

TT51 3

13 11 78

TT49

LIBERTY LOOP

LIBERTY LOOP

LI

B

E R

T Y

L O

O P

LANCASTER RD.

DESIGNATED

CONTRACTORS

PARKING AND

STAGING AREAS.

ANN A

RBOR A

VENUE

VETERANS D

RIVE

G

LA

D E

W A

TE

R

A N

N A

R B

O R

A V

E N

U E

LANCASTER RD.

A V

E N

U E

O F

F

LA

G S

A V

E N

U E

O F

F

LA

G S

LI

B

E R

T Y

L O

O P

LI

B

E R

T Y

L O

O P

LIBERTY LOOP

LIBERTY LOOPLIBERTY LOOP

MAIN MEDICAL

CENTER ENTRANCE

SOUTH

ENTRANCE

EAST GATE

NORTH

ENTRANCE

EAST GATE

AREA CAN BE

UTILIZED FOR

DUMPSTERS & LAY-

DOWN AREA

WING 8C-400

THIS AREA IS TO REMAIN OPERATIONAL

THROUGHOUT PROJECT DURATION.

PHASING PLAN GENERAL NOTES

A. THE PHASES WILL BE COORDINATED WITH THE OWNER IN ORDER

TO ESTABLISH AN UNDERSTANDING OF AREAS OF CONSTRUCTION,

VISITOR CIRCULATION AND GENERAL TIMELINES, HOWEVER, THE

BIDDER MAY PROPOSE ALTERNATIVES WHICH SAVE TIME AND

MONEY, BUT THE OWNER IS NOT REQUIRED TO ACCEPT THE

ALTERNATIVES PROPOSED IF THEY DETERMINE THAT PATIENT

CARE AND SAFETY MAY BE COMPROMISED.

B. ALL MECHANICAL SYSTEMS MUST BE OPERATIONAL THROUGH

DURATION OF PROJECT UNLESS NOTED OTHERWISE.

C. COORDINATE ALL UTILITY OUTAGES WITH THE OWNER AND STAFF A

MINIMUM OF 2-WEEKS IN ADVANCE.

D. MAINTAIN AIR-TIGHT SEAL BETWEEN OCCUPIED AND

CONSTRUCTION SPACES.

E. EXTERIOR OF BUILDING MUST BE LEFT SECURE WHEN

CONSTRUCTION WORKERS ARE NOT PRESENT.

F. MAINTAIN A MINIMUM OF 5'-0" CLEAR WIDTH IN ALL CORRIDORS

THROUGHOUT PROJECT DURATION.

G. DEAD ENDS MUST NOT EXCEED 30'-0".

H. LOCATE CONSTRUCTION BARRICADES SO THAT PATIENT TO

CONSTRUCTION WORKER CONTACT IS MINIMIZED.

I. COORDINATE WITH OWNER AND STAFF WHEN OPERATIONS WILL

TAKE PLACE WHICH WILL INVOLVE DISRUPTIVE NOISE LEVELS,

SUCH AS HAMMERING, DRILLING, SAWING, SCREW GUNS, ETC.

J. ELEVATOR LOBBY WORK SHALL BE DONE IN PHASES TO ENSURE

UNIMPEDED EGRESS. CONTRACTOR TO COORDINATE WITH OWNER

TO DETERMINE THAT PATIENT CARE AND SAFETY IS NOT

COMPROMISED ON OTHER FLOORS.

PHASING PLAN LEGEND

PHASE 1

PHASE 2

NOT IN SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: MR. ALEX MULLER-POITEVIEN, COR

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Architecture THESE DOCUMENTS

ARE FOR INTERIM

REVIEW AND ARE NOT

INTENDED FOR

CONSTRUCTION,

BIDDING, OR PERMIT

PURPOSES.

LBL Architects

1106 W. Randol Mill Rd, Suite 300

Arlington, TX 76012

817-265-1510 www.lblarchitects.com

OEI-LBL Joint Venture LLC

O'Brien Engineering, Inc., Managing Partner

Carrollton, TX 75006

972-233-2288

2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com

THOMAS R. MCCARTY

TEXAS ARCHITECT #20587

B

IM

/V

A D

A

T H

F L

O O

R /5

-2

-2

-A

-R

.r v t

/1 /2

:5

:1

A

M

2-GI-1.3

SITE & PHASING PLAN RENOVATE MEDICAL INPATIENT

UNIT FOR PATIENT PRIVACY &

COVID-19

DALLAS, TEXAS

549-20-222

11/04/2022 TM TT

11/04/2022

ISSUE FOR BID

1 : 1400

SITE PLAN

INFECTION CONTROL RISK ASSESSMENT (ICRA) CLASS IV

ICRA TEAM WILL MEET TO DISCUSS REQUIREMENTS AFTER

CONSTRUCTION CONTRACT IS AWARDED.

1" = 20'-0"

LEVEL 8 PHASING PLAN

Revisions: Date:

BEDROO-2

BED

STORAGE

CLOSET

CONFERENCE

ROOM

BEDROOM-ISOLATION

COMMUNICATION

CLOSET

ELEC.

ROOM

BEDROOM-2

BEDBEDROOM-2

BEDBEDROOM-

2 BED

BEDROOM-

2 BED

BEDROOM-

2 BED

LINEN

ROON,

CLEAN

BEDROOM-

ISLOATION

UTILITY

ROOM,

SOILED

UTILITY

ROOM,

CLEAN NOURISHEMENT

HAC

BEDROOM-

2 BED

BEDROOM-

2 BED

TOILET,

SHOWER

TOILET,

SHOWER

TOILET,

SHOWER

TOILET,

SHOWER

TOILET,

SHOWER

Room

TOILET,

SHOWER

NURSE

STATION

TOILET,

SHOWER

TOILET,

SHOWER

TOILET,

SHOWER

TOILET LOCKER

ROOM

ALCOVE,

MED

CORRIDOR-D

NURSE

SUB-STATION

Room

HALLWAY

TELE OFFICE

MEDICATION

ROOM

ELEVATOR

LOBBY MEDITATION

ROOM

BEDROOM-

1 BED

BEDROOM-ISOLATION

LINEN

ROOM,

CLEAN

CLOSET

BEDROOM-

2 BED BEDROOM-

2-BED BEDROOM-

1 BED

UTILITY

SHAFT

CLOSET,

ELECTRICAL

COMMUNICATION

CLOSET

BEDROOM-

ISLOATIONTOILET

BEDROOM-

ISOLATION

BEDROOM-

ISOLATION

LINEN

ROOM,

SOILED

KITCHEN

HAC

UTILITY

ROOM

CLEAN

BEDROOM-

2 BED

BEDROOM-

2 BED

BEDROOM-

2 BED

ALCOVE

NURSE

STATION

TOILET

TOILET

STAIRWAY-8

ALCOVE

CORRRIDOR

- D

CHASE

TOILET

ALCOVE

TOILET TOILET

TOILET,

SHOWER

TOILET,

SHOWER

TOILET,

SHOWER

STAIRWAY-5

TOILET,

SHOWER

TOILET,

SHOWER

NURSE

STATIONOFFICE

LOCKER

ROOM

TOILET,

STAFF

TOILET,

STAFF

ABC

ROOM

OXYGEN

ROOM

NURSE

SUB-

STATION

CORRIDOR

ALCOVE,

OMNICELL

IT

CLOSET

MECHANICAL

ROOM

OFFICE

WAITINGROOM

STAIRWAY-7

COMPUTER

ROOM

CORRIDOR-D

PIPE

CHASE

BREAKROOM

LOCKER

ROOM

UTILITY

ROOM

CLEAN

LINEN

ROOM

CLEAN

KITCHEN

NOURISHMENT

NURSE

STATION

STORAGE

INTERDISCIPLINARY

ROOM

CONFERENCE

ROOM

BEDROOM

BEDROOMBEDROOM

COMMUNICATIONS

ELECTRICAL

BEDROOM-ISOLATION

TOILET,

SHOWER

UTILITY

ROOM,

SOILED

BEDROOM

BEDROOM

BEDROOM-

ISLOATION

BEDROOM-

ISOLATION BEDROOM BEDROOM HAC

BEDROOM

ALCOVE

TOILETTOILET

TOILET,

SHOWER

TOILET TOILET

ALCOVE,

MED

CART

TOILET,

SHOWER

TOILET,

SHOWER

TOILET,

SHOWER

TOILET,

SHOWER

TOILET,

SHOWER

TOILET,

SHOWER

NURSE

SUB

STATION

MEDICATION

OFFICE

STAIRWAY-3

CLOSET

CORRIDOR-D

TOILET,

SHOWER NURSES

SUBSTATION

TOILET,

SHOWER

TOILET,

SHOWER

TOILET,

SHOWER

CORRIDOR-D

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: MR. ALEX MULLER-POITEVIEN, COR

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Architecture THESE DOCUMENTS

ARE FOR INTERIM

REVIEW AND ARE NOT

INTENDED FOR

CONSTRUCTION,

BIDDING, OR PERMIT

PURPOSES.

LBL Architects

1106 W. Randol Mill Rd, Suite 300

Arlington, TX 76012

817-265-1510 www.lblarchitects.com

OEI-LBL Joint Venture LLC

O'Brien Engineering, Inc., Managing Partner

Carrollton, TX 75006

972-233-2288

2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com

THOMAS R. MCCARTY

TEXAS ARCHITECT #20587

B

IM

/V

A D

A

T H

F L

O O

R /5

-2

-2

-A

-R

.r v t

/1 /2

:5

:3

A

M

2-AI-2.0

LEVEL 7 REFERENCE FLOOR PLAN RENOVATE MEDICAL INPATIENT

UNIT FOR PATIENT PRIVACY &

COVID-19

DALLAS, TEXAS

549-20-222

11/04/2022 TM DC

11/04/2022

ISSUE FOR BID

1/16" = 1'-0"

LEVEL 7 EXISTING FLOOR PLAN

REFERENCE PLAN: THIS SHEET IS PROVIDED

FOR REFERENCE PURPOSES ONLY.

Revisions: Date:

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CLOSET

CLOSET

FIRE EXT.

CONFERENCE

RM

OFFICE

TOILET

CLOSET

TOILET

CORRIDOR

REFRESHMENT

BAR

OFFICE

OFFICE

OFFICE

OFFICE

TOILET

ELECTRICAL

RM

STORAGE

COMMUNICATION

CLOSET

OFFICEOFFICE

OFFICE

OFFICE

TOILET

STAIRWELL-3

WAITING

TELECAR

ROOM

ELECTRICAL

TLT

COMMUNICATIONS

MECHANICAL

FAMILY

CONSULTATION/

EDUCATION

STAIRWELL

- 2

STAIRWELL

- 1

STAIRWELL

- 5

UTILITY

SHAFTCORRIDOR

JAN NOURISHMENT

SOILED

HOLDING

NURSE

MANAGER

NURSE

STATION

LOCKER

STAFF

LOUNGE

ELECTRICAL

CLEAN

UTILITY

PATIENT

RM

PATIENT

RM

PATIENT

RM

TLT/SHWR

TLT/SHWR

TLT/SHWR TLT/SHWR

TLT/SHWR

PATIENT

RM

ISO

BARIATRIC

PATIENT

RM

CLEAN

LINEN

MEDICAL

EQUIPMENT

MEDICATION

ISO

PATIENT

RM

ISO

PATIENT

RM

ISO

PATIENT

RM

ANTE

TLT/SHWR

ANTE

TLT/SHWR

ANTE

TLT

TLT

TLT/SHWR

MEDICAL

EQUIPMENT

CORRIDOR

TLT

CORRIDOR

ANTE

JANNOURISHMENT SOILED

HOLDING

NURSE

MANAGER

NURSE

STATION

LOCKER

STAFF

LOUNGE

CLEAN

UTILITY

PATIENT

RM

PATIENT

RMPATIENT

RM

TLT/SHWR

TLT/SHWR

TLT/SHWRTLT/SHWR

TLT/SHWR

PATIENT

RM

ISO

BARIATRIC

PATIENT

RM

CLEAN

LINEN

MEDICAL

EQUIPMENT

MEDICATION

ISO

PATIENT

RM

ISO

PATIENT

RM

ISO

PATIENT

RM

ANTE

TLT/SHWR

ANTE

TLT/SHWR

ANTE

TLT

TLT

TLT/SHWR

MEDICAL

EQUIPMENT

CORRIDOR

ANTE

ELECTRICAL

Room

OFFICE

CLOSET

CLOSET

P1

P2

P3

P4

S5

S6

P6

P7

ELEVATOR

LOBBY

ELEVATOR

LOBBY

2-AI-2.2

2-AI-2.4

2-AI-2.3

2-AI-2.5

2-AI-2.5

OVERALL PLAN GENERAL NOTES

A. OVERALL PLAN IS PROVIDED AS A REFERENCE. SEE SHEET

AI-2.2 FOR ADDITIONAL INFORMATION INVOLVING GENERAL

NOTES AND NOTES BY NUMBER.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: MR. ALEX MULLER-POITEVIEN, COR

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Architecture THESE DOCUMENTS

ARE FOR INTERIM

REVIEW AND ARE NOT

INTENDED FOR

CONSTRUCTION,

BIDDING, OR PERMIT

PURPOSES.

LBL Architects

1106 W. Randol Mill Rd, Suite 300

Arlington, TX 76012

817-265-1510 www.lblarchitects.com

OEI-LBL Joint Venture LLC

O'Brien Engineering, Inc., Managing Partner

Carrollton, TX 75006

972-233-2288

2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com

THOMAS R. MCCARTY

TEXAS ARCHITECT #20587

B

IM

/V

A D

A

T H

F L

O O

R /5

-2

-2

-A

-R

.r v t

/1 /2

:5

:4

A

M

2-AI-2.1

LEVEL 8 OVERALL FLOOR PLAN RENOVATE MEDICAL INPATIENT

UNIT FOR PATIENT PRIVACY &

COVID-19

DALLAS, TEXAS

549-20-222

11/04/2022 TM DC

11/04/2022

ISSUE FOR BID

1/16" = 1'-0"

LEVEL 8 FLOOR PLAN

Revisions: Date:

REF

FLOOR PLAN LEGEND:

NEW CONSTRUCTION

EXISTING TO REMAIN

FLOOR PLAN GENERAL NOTES

A. AT ROOMS AND AREAS SCHEDULED TO RECEIVE NEW FINISHES: REMOVE EXISTING FINISHES AND

PREPARE AS REQUIRED PER FINISH MANUFACTURERS RECOMMENDATIONS TO RECEIVE NEW

FINISH.

B. WHERE NEW WALLS ABUT EXISTING SURFACES TO REMAIN, WORK SHALL BE PERFORMED TO

CREATE A SEAMLESS APPEARANCE.

C. ADD WOOD BLOCKING, FIRE RETARDANT WHERE REQUIRED BY CODE, FOR SECURING ALL

FIXTURES, EQUIPMENT, CABINETRY, FURNISHINGS, AND ALL OTHER ITEMS REQUIRING SIMILAR.

PROVIDE ADDITIONAL STRUCTURAL SUPPORT (ANGLES, CHANNELS, ETC.) WITHIN WALLS WHERE

WEIGHT OF ATTACHED ITEMS IS TOO GREAT TO BE SUPPORTED BY STUDS. ENSURE FLUSH,

STRAIGHT, WELL- SECURED INSTALLATION CONDITIONS.

D. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF

CONSTRUCTION AND COORDINATE ACCORDINGLY.

E. ALL FURNITURE PROVIDED AND INSTALLED BY OWNER SHOWN UNTAGGED AND DASHED FOR

REFERENCE ONLY.

F. REFER TO REFLECTED CEILING PLAN FOR LOCATIONS OF SOUND ATTENUATED PARTITIONS AND

ASSEMBLIES.

G. WHERE DOORS ARE AGAINST PERPENDICULAR WALL, FRAME TYPICAL SO THAT THE HINGE SIDE

EDGE OF ROUGH OPENING IS 4” FROM PERPENDICULAR WALL, UNLESS NOTED OTHERWISE.

H. PLACEMENT OF MECHANICAL UNITS SHOWN ON ARCHITECTURAL PLANS ARE DIAGRAMMATIC AND

FOR REFERENCE ONLY.

I. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED FOR PROPER INSTALLATION OF MATERIAL AND EQUIPMENT. PROVIDE DEMOLITION AND PATCH/REPAIR IN ALL

AREAS (WHETHER SPECIFICALLY SHOWN OR NOT) TO ACCOMMODATE ALL WORK REQUIRED.

J. PROVIDE EMPTY CONDUIT, J-BOXES AND PULL STRINGS FOR ALL TELEPHONE, COMMUNICATION, AUDIO/VISUAL, AND OTHER LOW VOLTAGE SYSTEMS AS INDICATED.

K. REFER TO LIFE SAFETY DRAWINGS FOR ADDITIONAL FIRE / SMOKE RATING REQUIREMENTS.

L. REFER TO EQUIPMENT DRAWINGS FOR ADDITIONAL EQUIPMENT SPECIFIC INFORMATION.

M. TYPICAL PARTITION TYPES:

a. ALL NON-LOAD BEARING INTERIOR PARTITIONS ARE TYPE "A3" UNLESS NOTED

OTHERWISE. PROVIDE SOUND ATTENUATION BATTS (S.A.B.) AT ALL INTERIOR PARTITIONS.

b. PROVIDE FURRING AT ENTIRE PERIMETER OF EXTERIOR WALLS WITHIN PROJECT SCOPE

WITH PARTITION TYPE "E2". UNLESS NOTED OTHERWISE. FILL CAVITY WITH THERMAL

INSULATION.

c. PROVIDE FURRING AT EXISTING COLUMNS AND MASONRY WALLS WITHIN PROJECT SCOPE

WITH PARTITION TYPE "E1" UNLESS NOTED OTHERWISE.

d. PROVIDE TYPE "E3" FOR PLUMBING CHASE WALLS UNLESS NOTED OTHERWISE.

N. PROVIDE NEW EXPANSION JOINT COVERS AT ALL WALLS, FLOORS AND HARD CEILINGS IN NEW

CONSTRUCTION OR REMODELED AREAS WHERE E.J. OCCUR.

STAIRWELL - 1

195 SF

JAN

8C-115

70 SF

NOURISHMENT

8C-114

107 SF

SOILED

HOLDING

8C-116

124 SF

NURSE

MANAGER

8C-103

91 SF

NURSE STATION

8C-102

226 SF

LOCKER

8C-134

101 SF

STAFF LOUNGE

8C-133

173 SF

ELECTRICAL

8C-130

127 SF

CLEAN UTILITY

8C-131

114 SF

PATIENT RM

8C-123

247 SF

PATIENT RM

8C-121

247 SF

PATIENT RM

8C-119

256 SF

TLT/SHWR

8C-124

71 SF

TLT/SHWR

8C-129

84 SF

TLT/SHWR

8C-122

69 SF

TLT/SHWR

8C-120

73 SF

TLT/SHWR

8C-118

71 SF

PATIENT RM

8C-117

249 SF

ISO BARIATRIC

PATIENT RM

8C-128

289 SF

CLEAN LINEN

8C-126

66 SF

MEDICAL

EQUIPMENT

8C-125

142 SF

MEDICATION

8C-132

103 SF

TLT

8C-135

51 SF

TLT

8C-136

51 SF

CORRIDOR

8C-101

1,792 SF

ANTE

8C-127

51 SF

CHARTING

EQUIP. ALCOVE

EQUIP.

ALCOVE

CRASH

CART

EQUIP.

ALCOVE

OMNI

CELL

8C-103 0-F3 -3E.0

8C-111 0-U1 -4D.2

8C -1

17 0- U

-4

D .2

8C -1

15 0- F3

-5 D

.0

8C -1

16 60 -F

-5

D .0

8C-136 0-F3 -2.

8C-135 0-F3 -2.

8C -1

34 0- F3

-1 R

.0

8C-118

0-FS1 -2K.0

8C-122

0-FS1 -2K.0

8C-121 0-U1 -4D.2

8C-123 0-U1 -4D.2

8C-124

0-FS1 -2K.0

8C-120

0-FS1 -2K.0

8C-129

0-FS1 -2K.0

8C -1

27 0- U

-4

D .2

8C -1

28 0- U

-4

D .2

8C -1

26 0- F3

-5 D

.1

8C -1

25 0- U

-4

D .2

8C -1

19 0- U

1L L

-4 D

.2

8C-112 0-U1 -4D.2

8C -1

31 60 -F

-5

D .0

8C -1

32 60 -F

-S

H -3

C .3

8C -1

33 0- F3

-1 R

.0

CLOSET

STAIRWELL - 2

176 SF

8C-101 -N27 -12E.1

2-AI-4.44

U/C/B CABINET,

TYP.

14'-9" 7'-6"

4' -4

2-AI-4.4 1211

2-AI-4.4 8

2-AI-4.4 9

ADA

BENCH

ADA

CLEAR

30" X 48"

2-AI-4.4

2-AI-4.4

2-AI-4.4 3

LO

C

K E

R S

A1

S2

S2

S2

S2

S2

S2 S2

S2

S2

S2

MS12-AI-4.4 15

S4

S4

S4 S4

2-AI-3.1

13'-2"

CLEAR

8'-0"

1'-2 1/2"

14'-5" 8'-6"

2'-6"

6'-0" 8'-4"

C

LE

AR

9' -0

8'

-1

8' -6

C

LE

AR

9' -0

C

LE

AR

'-1

/4

4'

-0

/4

3' -8

8'

-1 0"

V .I.

F.

6' -2

1' -2

/2

C

LE

AR

8' -0

1'-11 1/4"

1'-2"

CLEAR

8'-0"

V.I.F.

20'-2"

13'-2"

CLEAR

8'-0" 1'-2"

CLEAR

8'-0" 19'-7"

CLEAR

9'-0" 19'-11" 10'-7"

1'-5"

V.I.F.

5'-0 1/2" 8'-10" 8'-2" 10'-7" 11'-8"

3' -0

V .I.

F.

9' -1

1/

2"

3' -0

V .I.

F.

'-2

/4

V .I.

F.

8' -1

0"

V .I.

F.

6' -1

1/

2" 8'

-6

V.I.F.

8'-0 1/4" 7'-10 3/4" 12'-8"

1'-2"

7'-5" 6'-9"

V.I.F.

1'-4 1/2"

7' -8

/4

V .I.

F.

7' -8

/2

3'-7"

A6

A6

A6

A6

A6A6

A2

A2

A3

A3

A3

A3

A3

A2

2' -1

3'

-6

1'-7"

1' -0

2' -1

0"

S1

WC1

SH2

S1

WC1

SH2

S1

WC1

S1

WC1

S1

WC1

SH1

S1

WC1

S1

WC1

2-AI-3.1

2-AI-3.1

2-AI-3.1

2-AI-3.1

135°

45°

135°

V.I.F.

2'-3" 12'-2" 4'-0" 1'-7"

CLEAR

5'-0" 5'-7"

3' -0

3' -0

3'-0" 3'-2"

A4

A4

A5

3'-9" 3'-0"

1'-6" MIN.1'-6" MIN. 1'-6" MIN.

MIN.

1'-6"

C

LE

AR

5'

-0

M

IN

1' -0

2-AI-2.9

SH2

SH2

PROVIDE ACCESS DOOR

KEYPLAN

AREA 100-A AREA 200-A

AREA 300

AREA 100-B AREA 200-B

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: MR. ALEX MULLER-POITEVIEN, COR

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Architecture THESE DOCUMENTS

ARE FOR INTERIM

REVIEW AND ARE NOT

INTENDED FOR

CONSTRUCTION,

BIDDING, OR PERMIT

PURPOSES.

LBL Architects

1106 W. Randol Mill Rd, Suite 300

Arlington, TX 76012

817-265-1510 www.lblarchitects.com

OEI-LBL Joint Venture LLC

O'Brien Engineering, Inc., Managing Partner

Carrollton, TX 75006

972-233-2288

2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com

THOMAS R. MCCARTY

TEXAS ARCHITECT #20587

B

IM

/V

A D

A

T H

F L

O O

R /5

-2

-2

-A

-R

.r v t

/1 /2

:5

:5

A

M

2-AI-2.2

LEVEL 8 ENLARGED FLOOR PLAN -

AREA 100-A

RENOVATE MEDICAL INPATIENT

UNIT FOR PATIENT PRIVACY &

COVID-19

DALLAS, TEXAS

549-20-222

11/04/2022 TM DC

11/04/2022

ISSUE FOR BID

FLOOR PLAN NOTES BY NUMBER

A1 PROVIDE LEAD LINING AT FULL PERIMETER OF ROOM. ALL OPENINGS INTO ROOM TO BE LEAD

LINED AS WELL.

A2 ALIGN EXISTING AND NEW WALL SO THAT FACE OF FINISH IS IN SAME PLANE.

A3 MEDICAL GASES, SEE SHEET 2 A1-4.5 (EQUIPMENT MOUNTING HEIGHTS DIAGRAM).

A4 7'-0" GWB WRAPPED METAL STUD CASED OPENING WITH CORNER GUARDS.

A5 OVERHEAD PRIVACY CURTAIN TRACKS, TYPICAL.

A6 SWING UP GRAB BARS, TYPICAL. SEE TOILET ACCESSORIES SHEET 2AI-4.5.

A1

1/4" = 1'-0"

LEVEL 8 ENLARGED FLOOR PLAN - AREA 100-A

Revisions: Date:

MECHANICAL

8C-302

1,185 SF

FAMILY

CONSULTATION/

EDUCATION

8C-311

186 SF

STAIRWELL - 1

195 SF

TLT

8C-306

59 SF

ELECTRICAL

8C-307

93 SF

TELECAR ROOM

8C-308

124 SF

WAITING

8C-309

348 SF

COMMUNICATIONS

8C-303

156 SF

CORRIDOR

8C-301

438 SF

P-6

P-7

P-1

P-2

P-3

P-4

S-5

S-6

NURSE

MANAGER

8C-103

91 SF

TLT

8C-305

59 SF

CORRIDOR

8C-304

94 SF

Room

8C-310

46 SF

OFFICE

8C-312

276 SF

CLOSET

8C-312

7 SF

8C -3

02 90 -F

-5

D .2

8C-302

90-F21 -SH-14.1

8C -3

03 60 -F

-5

D .0

8C -3

08 60 -F

-3

E .0

8C-201

-N27 -12E.1

8C-306

0-F3 -2.

8C-305

0-F3 -2.

8C -3

07 60 -F

-5

D .0

8C-101

-N27 -12E.1

LO

C

K E

R S

V.I.F.

1'-4 1/2"

3'-7" V.I.F.

19'-6 1/2"

6' -1

3/

4" 1'

-2

7' -3

/4

8'

-1 0"

V .I.

F.

'-1

V .I.

F.

1' -6

/4

A2

90 90

WC1

S1

WC1

S1

2-AI-3.1

2-AI-3.1

A2

6'-6"

3'-2"

3'-9 1/4"

6'-8" 8'-6"

1'-6"

8C-304

0-C5

KEYPLAN

AREA 100-A AREA 200-A

AREA 300

AREA 100-B AREA 200-B

FLOOR PLAN NOTES BY NUMBER:

REFER TO SHEET 2-AI-2.2

FLOOR PLAN GENERAL NOTES

REFER TO SHEET 2-AI-2.2

FLOOR PLAN LEGEND:

NEW CONSTRUCTION

EXISTING TO REMAIN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: MR. ALEX MULLER-POITEVIEN, COR

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Architecture THESE DOCUMENTS

ARE FOR INTERIM

REVIEW AND ARE NOT

INTENDED FOR

CONSTRUCTION,

BIDDING, OR PERMIT

PURPOSES.

LBL Architects

1106 W. Randol Mill Rd, Suite 300

Arlington, TX 76012

817-265-1510 www.lblarchitects.com

OEI-LBL Joint Venture LLC

O'Brien Engineering, Inc., Managing Partner

Carrollton, TX 75006

972-233-2288

2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com

THOMAS R. MCCARTY

TEXAS ARCHITECT #20587

B

IM

/V

A D

A

T H

F L

O O

R /5

-2

-2

-A

-R

.r v t

/1 /2

:5

:0

A

M

2-AI-2.3

LEVEL 8 ENLARGED FLOOR PLAN -

AREA 300

RENOVATE MEDICAL INPATIENT

UNIT FOR PATIENT PRIVACY &

COVID-19

DALLAS, TEXAS

549-20-222

11/04/2022 Checker Author 11/04/2022

ISSUE FOR BID

1/4" = 1'-0"

LEVEL 8 ENLARGED FLOOR PLAN - AREA 300

Revisions: Date:

FLOOR PLAN NOTES BY NUMBER:

REFER TO SHEET 2-AI-2.2

FLOOR PLAN GENERAL NOTES

REFER TO SHEET 2-AI-2.2

FLOOR PLAN LEGEND:

NEW CONSTRUCTION

EXISTING TO REMAIN

STAIRWELL - 5

162 SF

TLT

8C-306

59 SF

COMMUNICATIONS

8C-303

156 SF

UTILITY SHAFT

52 SF

TLT

8C-305

59 SF

JAN

8C-223

70 SF

NOURISHMENT

8C-224

107 SF

SOILED

HOLDING

8C-222

124 SF

NURSE

MANAGER

8C-236

91 SF

NURSE STATION

8C-235

230 SF

LOCKER

8C-202

104 SF

STAFF LOUNGE

8C-205

166 SF

CLEAN UTILITY

8C-207

115 SF

PATIENT RM

8C-214

247 SF

PATIENT RM

8C-216

247 SF

PATIENT RM

8C-218

256 SF

TLT/SHWR

8C-215

70 SF

TLT/SHWR

8C-211

84 SF

TLT/SHWR

8C-217

70 SF

TLT/SHWR

8C-219

73 SF

TLT/SHWR

8C-221

71 SF

PATIENT RM

8C-220

249 SF

ISO BARIATRIC

PATIENT RM

8C-210

289 SF

CLEAN LINEN

8C-212

62 SF

MEDICAL

EQUIPMENT

8C-213

142 SF

MEDICATION

8C-206

102 SF

TLT

8C-204

51 SF

TLT

8C-203

51 SF

CORRIDOR

8C-201

1,843 SF

CHARTING

EQUIP. ALCOVE

EQUIP.

ALCOVE

CRASH

CART

EQUIP.

ALCOVE

OMNI

CELL

ELECTRICAL

8C-208

131 SF

ANTE

8C-209

51 SF

8C -3

03 60 -F

-5

D .0

8C -2

08 60 -F

-4

N

8C-201

-N27 -12E.1

8C -2

20 0 -U

-4

D .2

8C-225

0-U1 -4D.2

8C -2

23 0 -F

-5

D .0

8C -2

22 60 -F

-5

D .0

8C-236

0-F3 -3E.0

8C-203

0-F3 -2.

8C-204

0-F3 -2.

8C -2

02 0 -F

-1

R .0

8C-221

0-FS1 -2K.0

8C-217

0-FS1 -2K.0

8C-216

0-U1 -4D.2

8C-214

0-U1 -4D.2

8C-215

0-FS1 -2K.0

8C-219

0-FS1 -2K.0

8C-211

0-FS1 -2K.0

8C -2

09 0 -U

-4

D .2

8C -2

10 0 -U

-4

D .2

8C -2

12 0 -F

-5

D .1

8C -2

13 60 -U

-4

D .2

8C -2

18 0 -U

1L L

-4 D

.2

8C-226

0-U1 -4D.2

8C -2

07 60 -F

-5

D .0

8C -2

06 60 -F

-S

H -3

C .3

8C -2

05 0 -F

-1

R .0

A

A

A1

S2 S2

S2

S2

S2S2

S2

S2

S2

MS1

S2

8'-4" 6'-0" 2'-6"

8'-6" 14'-5" 1'-2 3/4"

CLEAR

8'-0"

V.I.F.

13'-1"

C

LE

AR

9' -0

8'

-1

8' -6

C

LE

AR

9' -0

2-AI-3.1

A6

A6A6

A6

A6

3' -0

A6

A3

A3

A3

A3

A3

2' -1

1'-2"

1'-10 1/2"

V.I.F.

20'-1 1/4"

CLEAR

8'-0"

S1

WC1 SH2

S1

WC1 SH2

S1

WC1SH2

S1

WC1

SH2

S1

WC1

SH1

S1

WC1

S1

WC1

WC1

WC1

2-AI-3.1

2-AI-3.1

2-AI-3.1

2-AI-3.1

2-AI-3.1

7' -8

/4

V .I.

F.

7' -8

/2

A4

A4

2-AI-4.46

THIS ROOM IS SIMILAR

TO 8C-102, ALL NOTES

APPLY, U.N.O.

THIS ROOM IS SIMILAR

TO 8C-114, ALL NOTES

APPLY, U.N.O.

2-AI-4.4 11

3'-9 1/4" 3'-5 1/2" 3'-5 1/2"

V.I.F.

8'-9 1/4"8'-1"7'-10"12'-8"

1'-2" 7'-0"7'-4"

8' -1

0" 6'

-1

1/ 2"

8' -6

'-1

/4

4'

-0

/4

3' -8

8'

-1 0"

6' -2

1' -2

/2

8' -6

/4

3' -0

V .I.

F.

9' -1

1/

2"

2' -1

0"

13'-1"

CLEAR

8'-0" 1'-2 3/4"

CLEAR

8'-0"19'-7"

CLEAR

9'-0"19'-6 1/4"10'-7"1'-5 3/4"

5'-0"

9'-3"8'-2"10'-7"11'-8"

A5

5'-7"

1'-6" MIN.

MIN.

1'-6"

C

LE

AR

5' -0

M

IN

1' -0

A6

PROVIDE ACCESS DOOR

KEYPLAN

AREA 100-A AREA 200-A

AREA 300

AREA 100-B AREA 200-B

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: MR. ALEX MULLER-POITEVIEN, COR

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Architecture THESE DOCUMENTS

ARE FOR INTERIM

REVIEW AND ARE NOT

INTENDED FOR

CONSTRUCTION,

BIDDING, OR PERMIT

PURPOSES.

LBL Architects

1106 W. Randol Mill Rd, Suite 300

Arlington, TX 76012

817-265-1510 www.lblarchitects.com

OEI-LBL Joint Venture LLC

O'Brien Engineering, Inc., Managing Partner

Carrollton, TX 75006

972-233-2288

2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com

THOMAS R. MCCARTY

TEXAS ARCHITECT #20587

B

IM

/V

A D

A

T H

F L

O O

R /5

-2

-2

-A

-R

.r v t

/1 /2

:5

:1

A

M

2-AI-2.4

LEVEL 8 ENLARGED FLOOR PLAN -

AREA 200-A

RENOVATE MEDICAL INPATIENT

UNIT FOR PATIENT PRIVACY &

COVID-19

DALLAS, TEXAS

549-20-222

11/04/2022 Checker Author 11/04/2022

ISSUE FOR BID

1/4" = 1'-0"

LEVEL 8 ENLARGED FLOOR PLAN - AREA 200-A

Revisions: Date:

ISO PATIENT RM

8C-106

303 SF

ISO PATIENT RM

8C-109

280 SF

ISO PATIENT RM

8C-112

279 SF

ANTE

8C-111

80 SF

TLT/SHWR

8C-113

79 SF

ANTE

8C-108

80 SF

TLT/SHWR

8C-110

79 SF

ANTE

8C-105

79 SF

TLT/SHWR

8C-107

81 SF

MEDICAL

EQUIPMENT

8C-104

99 SF

E Q

U

IP

A

L C

O V

E E

Q U

IP

A

L C

O V

E

8C-111

0-U1 -4D.2

8C-112

0-U1 -4D.2

8C-108

0-U1 -4D.2

8C-109

0-U1 -4D.2

8C-105

0-U1 -4D.2

8C-106

0-U1 -4D.2

C

-1

-U

-4 D

.2

8C-107

0-FS1 -2K.0

8C-110

0-FS1 -2K.0

8C-113

?-FS1 -2K.0

4' -4

S2

S2

S2

S2

S2

S2

S2

S2

S4

8' -1

1"

'-7

8' -1

1"

'-7

8' -1

1"

'-1

1' -0

11'-10" 3'-4" 8'-4" 1'-3" 1'-11"

V.I.F.

8'-11"

A6

A6

A6

A6

A6

A6

9' -8

2'

-8

A2

A3

A3

A3

A3

E3

6' -1

0"

'-8

6' -1

0"

'-8

6' -1

0" 2'

-1

'-6

'-6

'-0

1'-3"

1'-7"

S1

WC1

S1

WC1

S1

WC1

SH2

SH2

SH1

M

IN

1' -6

M

IN

1' -6

M

IN

1' -6

C

LE

AR

5' -0

M

IN

1' -0

2-AI-4.4

NURSE STATION

8C-235

230 SF

ISO PATIENT RM

8C-232

300 SF

ISO PATIENT RM

8C-229

280 SF

ISO PATIENT RM

8C-226

279 SF

ANTE

8C-225

80 SF

TLT/SHWR

8C-227

79 SF

ANTE

8C-228

79 SF

TLT/SHWR

8C-230

79 SF

ANTE

8C-231

79 SF

TLT/SHWR

8C-233

81 SF

MEDICAL

EQUIPMENT

8C-234

99 SF

E Q

U

IP

A

L C

O V

E

E Q

U

IP

A

L C

O V

E

8C-225

0-U1 -4D.2

8C-226

0-U1 -4D.2

8C-228

0-U1 -4D.2

8C-229

0-U1 -4D.2

8C-231

0-U1 -4D.2

8C-232

0-U1 -4D.2

C

-2

-U

-4 D

.2

8C-233

0-FS1 -2K.0

8C-230

0-FS1 -2K.0

8C-227

0-FS1 -2K.0

S2

S2

S2

S2

S2

S2

S2

S2

MS1

8'-11" 1'-11"

1'-3"

8'-4" 3'-4" V.I.F.

11'-10"

A6

A6

A6

A6

A6

A3

A3

A3

A3

E3

E3

E3

A6

'-0

'-6

'-6

9' -8

2'

-8

6' -1

0"

'-8

6' -1

0"

'-8

6' -1

0" 2'

-1

8' -1

1"

'-7

8' -1

1"

'-7

8' -1

1"

'-1

1' -0

S1

WC1

S1

WC1

S1

WC1

SH2

SH2

SH1

A4

2-AI-4.4 1

10'-7"9'-3"8'-2"

M

IN

1' -6

M

IN

1' -6

M

IN

1' -6

M

IN

1' -0

KEYPLAN

AREA 100-A AREA 200-A

AREA 300

AREA 100-B AREA 200-B

FLOOR PLAN NOTES BY NUMBER:

REFER TO SHEET 2-AI-2.2

FLOOR PLAN GENERAL NOTES

REFER TO SHEET 2-AI-2.2

FLOOR PLAN LEGEND:

NEW CONSTRUCTION

EXISTING TO REMAIN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: MR. ALEX MULLER-POITEVIEN, COR

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Architecture THESE DOCUMENTS

ARE FOR INTERIM

REVIEW AND ARE NOT

INTENDED FOR

CONSTRUCTION,

BIDDING, OR PERMIT

PURPOSES.

LBL Architects

1106 W. Randol Mill Rd, Suite 300

Arlington, TX 76012

817-265-1510 www.lblarchitects.com

OEI-LBL Joint Venture LLC

O'Brien Engineering, Inc., Managing Partner

Carrollton, TX 75006

972-233-2288

2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com

THOMAS R. MCCARTY

TEXAS ARCHITECT #20587

B

IM

/V

A D

A

T H

F L

O O

R /5

-2

-2

-A

-R

.r v t

/1 /2

:5

:2

A

M

2-AI-2.5

LEVEL 8 ENLARGED FLOOR PLAN -

AREAS 100-B & 200-B

RENOVATE MEDICAL INPATIENT

UNIT FOR PATIENT PRIVACY &

COVID-19

DALLAS, TEXAS

549-20-222

11/04/2022 Checker Author 11/04/2022

ISSUE FOR BID

1/4" = 1'-0"

LEVEL 8 ENLARGED FLOOR PLAN - AREA 100-B 1/4" = 1'-0"

LEVEL 8 ENLARGED FLOOR PLAN - AREA 200-B

Revisions: Date:

'-6

2-FCU8

BUS

8JHES

8J

LE

C 8J

L

8JH J

D A

T A

JH

EC

JH

EQ

JL

EQ

A. EXISTING PLAN CONFIGURATION & BUILDING INFORMATION HAS BEEN PROVIDED

BY THE OWNER AND BELIEVED TO REFLECT CURRENT CONDITIONS, CONTRACTOR

TO CONFIRM ALL EXISTING CONDITIONS PRIOR TO COMMENCING WORK. NOTIFY

ARCHITECT IF INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS ARE

DISCOVERED.

B. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT

FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION.

C. CONTRACTOR TO COORDINATE EXTENT OF DEMOLITION WORK REQUIRED WITH

WORK SHOWN ON PROPOSED FLOOR PLANS.

D. PROTECT ALL EXISTING WORK TO REMAIN & REPAIR DAMAGED AREAS TO MATCH

EXISTING ADJACENT SURFACES UNLESS NOTED OTHERWISE.

E. CONTRACTOR TO COORDINATE DEMOLITION ACTIVITIES WITH OWNER SO AS TO

MAINTAIN FULL FUNCTIONALITY OF ADJACENT OWNER OCCUPIED SPACES.

F. CONTRACTOR TO MAINTAIN MEANS OF EGRESS PATHWAYS AT ALL TIMES.

COORDINATE ALTERNATE PROVISIONS AND OBTAIN APPROVAL FROM OWNER AND

AUTHORITY HAVING JURISDICTION IF EXISTING MEANS OF EGRESS MUST BE

COMPROMISED.

G. WHERE EXISTING FINISHES ARE TO BE REMOVED, PATCH & PREPARE SUBSTRATE

TO RECEIVE NEW FINISHES IN ACCORDANCE WITH NEW FINISH MATERIAL

MANUFACTURER’S RECOMMENDATIONS.

H. UTILITIES THAT REMAIN, WITHIN EXISTING WALLS TO BE DEMOLISHED, ARE TO BE

REROUTED AS REQUIRED TO FACILITATE THE NEW PLAN CONFIGURATION.

I. LABEL & PACKAGE ALL COMPONENTS OF SALVAGED ITEMS TO BE DELIVERED TO

OWNER. COORDINATE LABEL & PACKAGE REQUIREMENTS & STORAGE LOCATION

WITH OWNER.

J. CONTRACTOR TO PROVIDE FIRE, SMOKE, DIRT, DUST & NOISE CONTAINMENT

BARRIERS BETWEEN THE WORK AREA & THE ADJACENT OWNER OCCUPIED

SPACES.

K. CONTRACTOR TO COORDINATE ALL UTILITY SYSTEM SHUTDOWN ACTIVITIES IN

ADVANCE WITH THE OWNER AND MAINTAIN FULL FUNCTIONALITY OF ADJACENT

OWNER OCCUPIED SPACES.

L. CONTRACTOR TO REMOVE ALL DEMOLITION DEBRIS AND CONSTRUCTION DEBRIS

ON A DAILY BASIS, COORDINATE MEANS, METHODS & ROUTES AND INFECTION

CONTROL PROTOCOLS WITH THE OWNER.

M. WHERE SELECTIVE DEMOLITION IS REQUIRED ADJACENT TO EXISTING SURFACES

TO REMAIN, PATCH AND REPAIR TO MATCH EXISTING SURFACES UNLESS NOTED

OTHERWISE.

N. ALL UTILITY SYSTEMS & OTHER COMPONENTS THAT ARE SCHEDULED FOR

DISCONNECTION SHALL BE REMOVED IN THEIR ENTIRETY, “DISCONNECT, CAP &

ABANDON IN PLACE” IS NOT ACCEPTABLE – UNLESS SPECIFICALLY NOTED

OTHERWISE.

O. REMOVE ALL INTERIOR FINISHES AND FURRING BACK TO INSIDE FACE OF

MASONRY AT EXTERIOR WALLS WITHIN PROJECT SCOPE U.N.O.

P. ALL FIRE BARRIER WALLS SHALL MEET 1 HOUR FIRE RATING WITH 45 MINUTE

RATED DOORS.

Q. CONTRACTOR SHALL PROVIDE ONE OF THE FOLLOWING (3) LIFE SAFETY

MEASURES LISTED BELOW IN ORDER TO MAINTAIN THE INTEGRITY OF THE FIRE

PROTECTION IN THE PROJECT AREA:

a. FIRE WATCH

b. INSTALL UPRIGHT SPRINKLERS

c. INSTALL HEAT DETECTION THROUGHOUT TO COMPLY WITH NFPA 72 SPACING.

THE DEVICES MUST BE COMPATIBLE WITH THE CURRENT FACILITY FIRE ALARM

SYSTEM.

S. ELEVATOR LOBBY WORK SHALL BE DONE IN PHASES TO ENSURE UNIMPEDED

EGRESS. CONTRACTOR TO COORDINATE WITH OWNER TO DETERMINE THAT

PATIENT CARE AND SAFETY IS NOT COMPROMISED ON OTHER FLOORS.

DEMOLITION PLAN GENERAL NOTES:

DEMOLITION PLAN LEGEND:

EXISTING TO BE DEMOLISHED

DEMOLITION AREA. MAJORITY OF WALLS, FLOORING,

CEILINGS, DUCTWORK, DOMESTIC WATER LINES AND

SIMILAR ABOVE CEILING INFRASTRUCTURE TO BE

REMOVED.

EXISTING TO REMAIN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: MR. ALEX MULLER-POITEVIEN, COR

VA FORM 08 - 6231

A

FULLY SPRINKLERED