This file attachment provides drawings related to a federal construction contract opportunity issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation seeks bids for Project 202-318-REHAB Building Construction at the TOGUS VA Medical Center in Augusta, Maine. The opportunity involves rehabilitation and repair work on an existing building as depicted in the 20MB set of drawings. Bids are due by the date listed in solicitation number 36C77624B0006 for the design-bid-build construction project awarded as a firm-fixed price contract. The solicitation targets offers from small businesses under a total set-aside.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ARCHITECTURAL SYMBOLS
SHEET NUMBER
A-100 Sheet Number
Discipline Code
A-1 1/8" = 1'-0"
View Name
VIEW TITLE
Drawing Scale
Drawing Number
1/8" = 1'-0"
View NameA-1 A101R101
VIEW TITLE WITH REFERENCES
Drawing Scale
Sheet Number
Drawing Number
Reference Sheet Number
EXTERIOR ELEVATIONS
INTERIOR ELEVATIONS
A-200
A1 Position on Sheet
Sheet Number
Position on Sheet
Sheet Number
A1
A2B2
B1
A-350
MATCH LINES
MATCHLINE
SEE: A1/A-101B
Sheet Number
Position on Sheet
AREA REFERENCE
A
SEE: (X/X-XXX)
Reference to Area
View Reference for Additional Information
BUILDING SECTION
Position on Sheet
Sheet Number
SIM
X
X-XXX
SIM
X
X-XXX
WALL SECTION
Position on Sheet
Sheet Number
X
X-XXX
SIM
DETAIL - SECTION
SIM
X
X-XXX
Position on Sheet
Sheet Number
DETAIL - PLAN/RCP
SIM
X
X-XXX
Position on Sheet
Sheet Number
DRAWING REVISIONS
Revision Number
NORTH ARROW
True North
PLAN
NORTH Plan North
0 4'-0" 8'-0" 16'-0"
IF THIS IS NOT A 42"x30" SHEET IT IS A
REDUCED SIZE PLOT, USE GRAPHIC
SCALE ACCORDINGLY.
GRAPHIC SCALE
COLUMN GRID LINES
Column Grid Line (New)
Column Grid Line (Existing)
1 2
A
B
LEVEL DATUM
LEVEL XX
0' - 0"
Level Name
Level Elevation
SPOT ELEVATION
0'-0"
Spot Elevation
ROOM TAG
ROOM
NAME
ABC123
150 SF
Room Name
Room Number
CEILING TAG
CEILING HEIGHT
1' - 0"
Ceiling Type
Ceiling Height
DOOR NUMBER TAG
New Door Door Number Tag
1A
Existing Door Door Number Tag
1A101
WINDOW TAG
Interior Window Tag
XX
XX
Exterior Window Tag
CURTAIN WALL TAG
XX
Interior Curtain Wall Tag
Exterior Curtain Wall Tag
XX
AD100
Room Code Room Area Or Volume
1T
CURTAIN PANEL TAG
Interior Curtain Wall Tag
WALL TYPE TAG
≠ A# B
C
V V Item - VA Supplied & Installed
V C ITEM -
VA Supplied & Contractor Installed
C C Item - Contractor Supplied & Installed
FFE Tag (By JSN)A1000
TM FFE Tag Furnished By VA Equipment Vendor
? KEYNOTE
1"
R 1/2"
90°
DIMENSION TO FACE OF
FINISH, FACE OF CONCRETE,
COLUMN CENTERLINE, OR AS
NOTED.
DIMENSIONS
1"
Symbol Indicates No Sound
Attenuation
Partition Type
CMU/Stud Width
Partition Modifier Partition Modifier II
KEYNOTE TAG
SEE A-720 STANDARD PARTITION TYPES
Contract Limit line Style
Not In Contract Area
CONTRACT LIMIT GRAPHIC
LINE STYLES
Centerline
Demolished
Deduct Alternate
Overhead
FURNITURE, FIXTURE, & EQUIPMENT
8'-6"1
Name
Room Name Room Number
Existing Finish Key
Ceiling Height
TM Toilet Accessory Tag. See A-730
REFLECTED CEILING SYMBOLS
RECESSED LUMINAIRE (24"x24")
SMOKE DETECTOR
HVAC RETURN
DIFFUSER
EXIT LIGHT
HVAC EXHAUST
DIFFUSER
RECESSED ROUND DOWNLIGHT LUMINAIRE - INSTALL CENTERED
IN ACOUSTICAL CEILING TILE UNO
ACOUSTICAL TILE CEILING (24x24) (AT-1- REFER TO IN601)
GYPSUM BOARD CEILING (PAINTED P-3 UNO REFER TO SHEET IN601
FOR FINISH LEGEND)
ACCESS PANEL
HVAC SUPPLY
DIFFUSER
SPRINKLER
NEW
SIDEWALL DIFFUSER
ACOUSTICAL FELT CEILING FINISH (AT-3- REFER TO IN601)
VANITY LIGHT FIXTURE SECURITY CAMERA
SDSA
NURSE CALL DOME LIGHT
PENDANT LIGHT FIXTURE
SPEAKERPS
CEILING MOUNTED UTILITY
LIGHT FIXTURE
OCCUPANCY SENSOROS
FIRE ALARM STROBES
CABLE SUSPENDED CEILING BAFFLE (AT-2- REFER TO IN601)
LINEAR SUSPENDED
LIGHT FIXTURE
DECORATIVE PENDANT
LIGHT FIXTURE
WALL SCONCE
STAIRWELL WALL LIGHT
HVAC SUPPLY LINEAR
DIFFUSER
*HATCHED LIGHTS INDICATE EMERGENCY POWER
MATERIALS LEGEND
CONCRETE (SECTION)
GRANULAR FILL
CONCRETE MASONRY UNITS
BRICK
RIGID INSULATION (SECTION)
ACOUSTIC/THERMAL INSULATION (SECTION)
STEEL (SECTION)
ALUMINUM (SECTION)
WOOD FINISH (SECTION)
LUMBER FINISH (SECTION)
EARTHWORK (SECTION)
STUD WALL (PLAN & SECTION)
EXISTING WALL TO REMAIN (PLAN & SECTION)
DEMOLISHED WALL (PLAN &
SECTION)
EXISTING TO REMAIN
EXISTING TO BE REMOVED
EXISTING TO REMAIN
NEW CONSTRUCTION
DOOR NUMBER
SYMBOL AND MINIMUM
CLEARANCES
18" MIN.
12" MIN.
6" MIN.
1A
WALL LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
TRIPLE C - The A/E Group 100 Pearl Street, 14th floor Hartfort, CT 06103
(315) 484-5958 Mat Perkins
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP
MES GROUP
550 North Reo St. Suite 203 Tampa, FL 33609
(813) 289-4700 Nicholas Stephensen, P.E.
STRUCTURAL
C&S Companies 2575 E Camelback Rd, Suite 740 Phoenix, AZ 85016
(602) 997-7536 Bryan K. Salt, P.E. S.E.
B
IM
/4
-3
C o n s tr u c t S u b s ta n c e
U s e
R e s id e n ti a l R e h a b
B u ild in g /4
-3
.A u g u s ta
.A rc h .r v t
/2
/2
:0
:4
A
M
A-001
SYMBOLS, & GENERAL NOTES 402-318
BLDG 258
07/26/2022 MRP CJL
100% CONSTRUCTION
DOCUMENTS
ISSUED FOR BIDDING
Construct Substance Use Residential Rehab
1 VA Center, Augusta, Maine
ABBREVIATIONS
° DEGREE
± PLUS/MINUS
⌀ DIAMETER
≈ ALMOST EQUAL
∠ ANGLE
℄ CENTER LINE
Δ DELTA, DEFLECTION
ϕ ELECTRICAL PHASE
≠ NOT EQUAL
Ω OHM, OMEGA
BOUNDARY LINE
FLOW LINE
≡ IDENTITY
INITIAL LENGTH
MOMENT LINE
PROPERTY LINE, PLATE
½ ONE HALF FRACTION
¼ ONE QUARTER FRACTION
¾ THREE QUARTERS FRACTION
> GREATER THAN
≥ GREATER THAN OR EQUAL TO
< LESS THAN
≤ LESS THAN OR EQUAL TO
ABCDEFGHIJKMNOPQRSTUVWXYZ 1234567890
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AAMA AMERICAN ARCHITECTURAL
MANUFACTURERS ASSOCIATION
AB ANCHOR BOLT, AUGER BORING
ABA ARCHITECTURAL BARRIERS ACT
ABC AGGREGATE BASE COURSE
ABS AIR BREAK SWITCH
AC ASBESTOS CEMENT OR ASPHALTIC
CONCRETE
ACB AIR CIRCUIT BREAKER
ACI AMERICAN CONCRETE INSTITUTE
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACS PNL ACCESS PANEL
ACSR ALUMINUM CONDUCTOR STEEL
REINFORCED
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADDL ADDITIONAL
ADDN ADDITION
ADH ADHESIVE
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
ADB AUTOMATIC DOOR BOTTOM
ADO AUTOMATIC DOOR OPERATOR
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGA AMERICAN GAS ASSOCIATION
AGC ASSOCIATED GENERAL CONTRACTORS
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
AHR ANCHOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
AL ALUMINUM
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
AM ACOUSTIC MATERIAL
AMP AMPERE
AMT AMOUNT
ANOD ANODIZE
ANSI AMERICAN NATIONAL STANDARDS
INSTITUTE
ANT ANTENNA
AP ACCESS PANEL, APPROX.,
APPROXIMATE
APA AMERICAN PLYWOOD ASSOCIATION
APPD APPROVED
APPROX APPROXIMATE
APT APARTMENT
AR AS REQUIRED
ARR ARRESTOR
ARCH ARCHITECT, ARCHITECTURAL
ASB ASBESTOS
ASI ARCHITECT'S SUPPLEMENTAL
INSTRUCTION
ASKLR AUTOMATIC SPRINKLER
ASPH ASPHALT
ASSN ASSOCIATION
ASTM AMERICAN SOCIETY FOR TESTING AND
MATERIALS
ATCH ATTACHMENT
ATM AUTOMATIC TELLER MACHINE
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVE AVENUE
AVG AVERAGE
AW ACID WASTE
AWI ARCHITECTURAL WOODWORKING
INSTITUTE
AWPA AMERICAN WOOD PRESERVERS'
ASSOCIATION
AWS AMERICAN WELDING SOCIETY
AWT ACOUSTICAL WALL TREATMENT
B BASELINE, BOTTOM
B LABEL CLASS B DOOR
B PL BASE PLATE
BALC BALCONY
BAT BATTEN
BB BULLETIN BOARD
BD BOARD
BD FT BOARD FEET (FOOT)
BEJ BRICK EXPANSION JOINT
BEV BEVEL
BHMA BUILDER'S HARDWARE
MANUFACTURER'S ASSOCIATION
BI FLD DR BIFOLDING DOORS
BITUM BITUMINOUS
BKG BACKING
BLD BUILD
BLDG BUILDING
BLKT BLANKET
BLVD BOULEVARD
BM BEAM OR BENCHMARK
BO BOARD
BOT BOTTOM
BR BEDROOM, BOTTOM REGISTER
BRCG BRACING
BRDG BRIDGING
BRDG JST BRIDGING JOIST
BRG BEARING
BRG PL BEARING PLATE
BRKT BRACKET
BRZ BRONZE
BSMT BASEMENT
BTWN BETWEEN
BU BUSHEL
BUR BUILT-UP ROOFING
C CELSIUS, CHANNEL
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
C TO C CENTER TO CENTER
CAB CABINET
CAC CEILING ATTENUATION CLASS
CB CATCH BASIN, CORNER BEAD, CIRCUIT
BREAKER
CBB CEMENTITIOUS (BACKER) BOARD
CC CUBIC CENTIMETER, CONTRACTOR
SUPPLIED & INSTALLED
CCTV CLOSED CIRCUIT TELEVISION
CCW COUNTERCLOCKWISE
CD CONSTRUCTION DOCUMENTS,
CONTRACT DOCUMENTS, CEILING
DIFFUSER
CEM CEMENT
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED /
CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER
INSTALLED
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CENTER OF GRAVITY, CORNER GUARD
C&G CURB AND GUTTER
CGSFU CERAMIC GLAZED STRUCTURAL
FACING UNITS
CH CHILLER
CH BD CHALKBOARD
CHEM CHEMICAL
CHFR CHAMFER
CHK CHECK
CI CAST IRON
CIP CAST-IN-PLACE
CIR CIRCLE
CIRC CIRCULAR
CJ CONSTRUCTION JOINT OR CONTROL
JOINT
CL CENTER LINE
CLDG CLADDING
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CM² SQUARE CENTIMETER
CM³ CUBIC CENTIMETER
CM CONSTRUCTION MANAGEMENT
CMP CORRUGATED METAL PIPE
CMPA CORRUGATED METAL PIPE ARCH
CMU CONCRETE MASONRY UNIT
CND CONDUIT
CNDS CONDENSATE
CNR CORNER
CNTR COUNTER
CO CARBON MONOXIDE, CERTIFICATE OF
OCCUPANCY, CLEANOUT, OR COMPANY
CO2 CARBON DIOXIDE
CODP CLEANOUT W/ DECK PLUG
COL COLUMN
COM COMMON
COMB COMBINATION, COMBINED
COMM COMMUNICATION
COMP COMPONENT
CONC CONCRETE
CONC FLR CONCRETE FLOOR
COND CONDENSER OR CONDITION
CONF CONFERENCE
CONN CONNECT, CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUE
CONTR CONTRACTOR, CONTRACTION
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CORR CORRIDOR
CP NON-REINFORCED CONCRETE PIPE
CPM CRITICAL PATH METHOD
CPRS COMPRESSIBLE
CPT CARPET
CR CHAIR, CRASH RAIL
CRS COLD ROLLED STEEL
CRSI CONCRETE REINFORCING STEEL
INSTITUTE
CS CONCRETE SEALER/SURFACE
CSB CONCRETE SPLASH BLOCK
CSG CASING
CSI CONSTRUCTION SPECIFICATIONS
INSTITUTE
CSK COUNTER SUNK
CSMT CASEMENT
CSWK CASEWORK
CT CERAMIC TILE, CURRENT
TRANSFORMER, COOLING TOWER
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTG COATING
CTR CENTER, CONTOUR, COOLING TOWER
RETURN
CTRL CONTROL
CTV CABLE TELEVISION
CU COPPER C
CUH CABINET UNIT HEATER
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD CUBIC YARD
CURT CURTAIN
CW COLD WATER
CWB CAPILLARY WATER BARRIER
CWR COLD WATER RETURN
CYL CYLINDER
CYL L CYLINDER LOCK
D DEPTH OR PENNY (NAIL)
D LABEL CLASS D DOOR
DAT DATUM
DB DECIBEL, DRY BUILT, DIRECT BURIAL
DBL DOUBLE
DBL GLZ DOUBLE GLAZE
DC DIRECT CURRENT
DD DIVERSION DIKE
DEG, ° DEGREE
DEL DELETE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DI DUCTILE IRON
DIA, DIAMETER
DIAG DIAGONAL DIAGRAM
DIAG DIAGRAM DIAGONAL
DIFF DIFFERENCE OR DIFFUSER
DIM DIMENSION
DIR DIRECTION
DISP DISPENSER
DIST DISTANCE
DIV DIVIDE OR DIVISION
DL DEAD LOAD
DMPR DAMPER
DN DOWN
DP DISTRIBUTION
DOC DOCUMENT
DOUG FIR DOUGLAS FIR
DOZ DOZEN
DR DOOR, DRAIN, DRESSING ROOM, OR
DRIVE
DR CL DOOR CLOSER
DR FR DOOR FRAME
DR OPNG DOOR OPENING
DS DOWNSPOUT, STORM DRAINAGE
STRUCTURE
DSGN DESIGN
DW DISHWASHER, DOMESTIC WATER
DWD DRINKING WATER DISPENSER
DWG DRAWING
DWTR DUMBWAITER
E EAST
E LABEL CLASS E DOOR
EA EACH
EAM EXCEPT AS NOTED
EAT ENTERING AIR TEMPERATURE
EF EACH FACE, EXHAUST FAN
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
EG EXHAUST GRILLE
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC
ELEC DR OP ELECTRIC DOOR OPENER
ELEV ELEVATOR
EMER EMERGENCY
EMER SHR EMERGENCY SHOWER
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
ENGR ENGINEER
ENVIR ENVIRONMENT
E/P EDGE OF PAVEMEMNT
EPA ENVIRONMENTAL PROTECTION
AGENCY
EPDM ETHYLENE PROPYLENE DIENE
MONOMER
EPO EMERGENCY POWER OFF
EPS EXPANDED POLYSTYRENE BOARD
(INSULATION)
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ER EXHAUST REGISTER
ERD EXISTING ROOF DRAIN
ESC ESCAPE OR ESCUTCHEON
ESCAL ESCALATOR
ESMT EASEMENT
ESP ESPECIALLY
EST ESTIMATE
ETC AND SO FORTH OR ET CETERA
EVAP EVAPORATIVE
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXP BT EXPANSION BOLT
EXP JT EXPANSION JOINT
EXST GR EXISTING GRADE
EXT EXTERIOR, EXTERNAL, OR
EXTINGUISHER
EXT GR EXTERIOR GRADE
F FAHRENHEIT, FEMALE, FIRE, FUSE,
FILTER
FA FIRE ALARM
FAB FABRIC
FABX FIRE ALARM BOX
FAC FACTOR
FACIL FACILITY
FAS FASCIA
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FCTY FACTORY
FD FLOOR DRAIN, FIRE DAMPER
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF&E, FFE FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD, FLAT HEAD SCREWS, FIRE
HYDRANT
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHP FULL HEIGHT PARTITION
FHWS FLAT HEAD WOOD SCREW
FIG FIGURE
FIL FILLET
FIN FINISH
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIN WD FINISH WOOD
FIXT FIXTURE
FJ FELT JOINT
FL FLOORLINE, FLOOR, FLASHING, FLOW
LINE
FLASH FLASHING
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLR FLOOR
FLR FIN FLOOR FINISH
FLR SK FLOOR SINK
FLUOR FLUORESCENT
FLUOR FIX FLUORESCENT FIXTURE
FM FACTORY MUTUAL
FM-G FACTORY MUTUAL GLOBAL
FO FINISHED OPENING
FOC FACE OF CONCRETE OR FACE OF CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
4 WAY FOUR WAY
FOS FACE OF SLAB OR FACE OF STUD
FOUNT FOUNTAIN
FOW FACE OF WALL
FP FIRE PROTECTION OR FIREPROOF
FPH FROST PROOF HYDRANT
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RATING, FIRE RESISTANT, OR
FRAME
FR SNK FLUSHING RIM SINK
FREQ FREQUENCY
FRMG FRAMING
FRP FIBER REINFORCED POLYESTER OR
FIBERGLASS REINFORCED PLASTIC
FRZ FREEZER
FS FEDERAL SPECIFICATION, FULL SIZE
FSTNR FASTENER
FT FEET OR FOOT
FTG FOOTING
FURG FURRING
FURN FURNISH OR FURNITURE
FUT FUTURE
FW FIRE WATER
FWC FABRIC WALLCOVERING
G GROUND, GAS LINE, GRAM
GA GAGE OR GYPSUM ASSOCIATION
GAL GALLON, GALVANIZED
GALV GALVANIC OR GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR, GLAZED
COATING
GD GUARD
GDR GUARD RAIL
GEN GENERAL OR GENERATOR
GFI GROUND FAULT INTERRUPT
GFMU GROUND FACE MASONRY UNIT
GFRC GLASS-FIBER-REINFORCED CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GFRP GLASS-FIBER-REINFORCED PLASTIC
GI GALVANIZED IRON
GL GLASS
GLZ-C GLAZED BLOCK-CMU
GLZ-T GLAZED BLOCK-CLAY TILE
GL BLK GLASS BLOCK
GLU LAM GLUED LAMINATED WOOD
GR GRADE
GR FL GROUND FLOOR
GRAN GRANITE
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GSU GLAZED STRUCTURAL UNIT
GT GROUT
GUAR GUARANTEE
GUT GUTTER
GW GROUND WATER
GWB GYPUSM WALL BOARD
GYP GYPSUM
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H HIGH, HEIGHT, HUMIDIFIER
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HAC HOUSEKEEPING AIDS CLOSET
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIBB
HC HOLLOW CORE, HANDICAPPED
HCWD HOLLOW CORE WOOD DOOR
HD HARD DRAWN
HDBD HARDBOARD
HDNR HARDENER
HDO HIGH DENSITY OVERLAY
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR
(FILTER)
HEX HEXAGON
HF HIGH FREQUENCY
HGR HANGER
HGSW HORN GAP SWITCH
HID HIGH INTENSITY DISCHARGE
HM HECTOMETER
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HMDF HOLLOW METAL DOOR AND FRAME
HMF HOLLOW METAL FRAME
HNDRL HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HOSP HOSPITAL
HP HIGH PRESSURE, HIGH POINT,
HORSEPOWER
HPS HIGH PRESSURE SODIUM
HQ HEADQUARTERS
HR HOUR
HS HEAT-STRENGTHENED (GLASS) OR
HIGH STRENGTH
HSE HOUSE
HSKPG HOUSEKEEPING
HST HOIST
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR
CONDITIONING
HVY HEAVY
HW HOT WATER, HEAD WALL
HYD HYDRANT
HYDR HYDRAULIC
HZ HERTZ
I INTERSTATE (HIGHWAY) OR MOMENT
OF INERTIA
IAQ INDOOR AIR QUALITY
IBC INTERNATIONAL BUILDING CODE
ID IDENTIFICATION, INSIDE DIAMETER, OR
INTERIOR DESIGN
ID NO IDENTIFICATION NUMBER
IE INVERT ELEVATION
ILLUM ILLUMINATION
IMC INTERMEDIATE METAL CONDUIT
INCL INCLUDED
IND INDEPENDENT OR INDUSTRIAL
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INTERCOM INTERCOMMUNICATION
INTL INTERNATIONAL
INV INVERT
IP INLET PROTECTION
IRBF INDUSTRIAL RESIN BASE FLOORING
IRMA INVERTED ROOF MEMBRANE ASSEMBLY
IWH INSTANTANEOUS WATER HEATER
JAN JANITOR
J-BOX, JB JUNCTION BOX
JC JANITOR CLOSET
JCT JUNCTION
JT JOINT
JST JOIST
K KILO
KCP KEENE'S CEMENT PLASTER
KD KILN DRIED OR KNOCKED DOWN
KG KILOGRAM
KN KILONEWTON
KIT KITCHEN
KO KNOCKOUT
KPL KICKPLATE
KV KILOVOLT
KVA KILOVOLT-AMPERE
KW KILOWATT
L ANGLE, LOUVER, LENGTH, LENGTH OF
CURVE
LA LIGHTING ARRESTOR
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAM GL LAMINATED GLASS
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUND
LC LEAD COVERED
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LH LEFT HAND
LHR LEFT HAND REVERSE
LHR LEFT HAND REVERSE, LATENT HEAT
RATIO
LIB LIBRARY
LIN LINEAR
LINO LINOLEUM
LIQ LIQUID
LKR LOCKER
LKR RM LOCKER ROOM
LKWASH LOCKWASHER
LL LEAD LINED, LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMST LIMESTONE
LNDSCP LANDSCAPE
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
L/S LITERS PER SECOND
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
LVC LENGTH OF VERTICAL CURVE
LVD LOUVERED
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LWIC LIGHTWEIGHT INSULATING CONCRETE
LYR LAYER
M METER, MEGA
MACH MACHINE
MACH RM MACHINE ROOM
MAINT MAINTENANCE
MAN MANUAL
MAS MASONRY
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MB MACHINE BOLT
MCB METAL CORNER BEAD
MD METAL DECK
ME MECHANICAL ENGINEER
MEAS MEASURE
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MED MEDICAL, MEDIUM
MEK METHYL ETHYL KETONE
MEL MELAMINE
MEMB MEMBRANE
MEMO MEMORANDUM
MEZZ MEZZANINE
MF MILL FINISH
MFD MANUFACTURED
MFG MANUFACTURING
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MGT MANAGEMENT
MH MANHOLE
MIC MICROPHONE
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM MINUTE
MIN MINUTE MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MIT MITER
MKR MARKER
ML METAL LATH
MLDG MOLDING (MOULDING)
MLO MAIN LUG ONLY
MLWK MILLWORK
mm MILLIMETER
MMP MEMBRANE WATERPROOFING
MO MASONRY OPENING OR MOTOR
OPERATED
MOD MODEL, MODIFY OR MODULE
MOD BIT MODIFIED BITUMEN
MON MONITOR
MOPR MOP RACK
MP MEDIUM PRESSURE
MR MOISTURE RESISTANT
MS MACHINE SCREW OR MOP SINK
M/S METERS PER SECOND
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
MW MICROWAVE
MWP MEMBRANE WATERPROOFING
N NORTH
NA NOT APPLICABLE
NAAMM NATIONAL ASSOCIATION OF
ARCHITECTURAL METAL
MANUFACTURERS
NAT NATURAL
NATL NATIONAL
NC NOISE CRITERIA, NON-CORROSIVE
NCOMBL NONCOMBUSTIBLE
NDC NOSE DOWN CURB
NE NORTHEAST
NEC NATIONAL ELECTRICAL CODE
NEG NEGATIVE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NEUT NEUTRAL
NFC NATIONAL FIRE CODE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NPS NOMINAL PIPE SIZE
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
NRCA NATIONAL ROOFING CONTRACTORS
ASSOCIATION
NRP NON-REMOVABLE
NS NARROW STILE
NTS NOT TO SCALE
NUM NUMERAL
NW NORTHWEST
O/O OUT TO OUT
O OXYGEN
OA OUTSIDE AIR OR OVERALL
OC ON CENTER
OCB OIL CIRCUIT BREAKER
OCC OCCUPY
OCT OCTAGON
OD OUTSIDE DIAMETER OUTSIDE
DIMENSION
OD OUTSIDE DIMENSION OUTSIDE
DIAMETER
OF/CI OWNER FURNISHED/CONTRACTOR
INSTALLED
OFD OVERFLOW DRAIN
OFF OFFICE
OF/OI OWNER FURNISHED/OWNER INSTALLED
OH OVERHANG, OVERHEAD
OH DR OVERHEAD (COILING) DOOR
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
OPT OPTIONAL
OR OPERATING ROOM, OUTSIDE RADIUS
ORD ORDNANCE OR OVERFLOW ROOF
DRAIN
ORG ORGANIC
ORIG ORIGINAL
ORN ORNAMENTAL
OSD OPEN SITE DRAIN
OSHA OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION
OVHD OVERHEAD
OUT OUTLET
OZ OUNCE
P PIPE, POLE
Pa PASCALES
PA PUBLIC ADDRESS
PAR PARALLEL OR PARAPET
PARA PARAGRAPH
PART PARTIAL
PAT PATTERN
PB PUSHBUTTON, PULL BOX
PBD PARTICLEBOARD
PC PIECE, POLYCARBONATE, PORTLAND
CEMENT, PRECAST
PCA PORTLAND CEMENT ASSOCIATION
PCC PRECAST CONCRETE
PCCP CONCRETE PAVEMENT
PCD PAPER CUP DISPENSER
PCF POUNDS PER CUBIC FOOT
PCP PORTLAND CEMENT PLASTER
PED PEDESTAL
PEN PENETRATE
PEND PENDANT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PGBD PEGBOARD
PHAR PHARMACY
PHOTO PHOTOGRAPH
PHS PHILLIPS HEAD SCREW
PI POINT OF INTERSECTION
PIV POST INDICATOR VALVE
PJF PREFORMED JOINT FILLER
PKG PACKAGE
PL PROPERTY LINE, PLATE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER OR PLASTIC
PLAS CMU PLASTER COVERED CMU
PLBG PLUMBING
PLYWD PLYWOOD
PMTL PAINTED METAL
PNEU PNEUMATIC
PNL PANEL
PNT PAINT
PO POST OFFICE, PURCHASE ORDER
PO PURCHASE ORDER POST OFFICE
POLY POLYETHYLENE (PLASTIC)
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATE
PREFIN PREFINISH
PRELIM PRELIMINARY
PREP PREPARATION
PRESS PRESSURE
PREV PREVIOUS
PRIM PRIMARY
PRKG PARKING
PRMLD PREMOLDED
PROJ PROJECT
PROP PROPERTY
PRV PRESSURE RELIEF VALVE
PS PULL SWITCH
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT, PNEUMATIC TUBE, PRESSURE
TREATED, POINT OF TANGENT
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE (PLASTIC), POINT
OF VERTICAL CURVE
PVG PAVING
PVI POINT OF VERTICAL INTERSECTION
PVT POINT OF VERTICAL TANGENT
PVMT PAVEMENT
PWR POWER
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QRY QUARRY
QT QUARRY TILE
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QTR QUARTER
QTY QUANTITY
QUAD QUADRANT
QUAL QUALITY
R RADIUS, RISER, RUBBER, RETURN
RA RETURN AIR
RAD RADIATOR, RADIUS
RB RESILIENT BASE OR RUBBER BASE
RB HK ROBE HOOK
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REMOTE CONTROL
RCP REFLECTED CEILING PLAN,
REINFORCED CONCRETE PIPE
RCVR RECEIVER
RD ROAD OR ROOF DRAIN
REC RECESSED
RECD RECEIVED
RECPT RECEPTACLE
RECT RECTANGLE
RED REDUCING
REF REFERENCE OR REFRIGERATOR
REFR REFRACTORY, REFRIGERATION
REG REGISTER, REGULATOR
REINF REINFORCE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
RESIL T RESILIENT TILE
RET RETURN
REV REVISION
RF RADIO FREQUENCY, ROOF, RETURN
FAN
RFG ROOFING
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RGS RIGID GALVANIZED STEEL
RH RIGHT HAND
RHC REHEAT COIL
RHMS ROUND HEAD MACHINE SCREW
RHR RIGHT HAND REVERSE
RHWS ROUND HEAD WOOD SCREW
RI RUBBER INSULATED
RL ROOF LEADER
RLG RAILING
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RPM REVOLUTIONS PER MINUTE
RS ROUGH SAWN
RT RIGHT
RV ROOF VENT
RVS REVERSE
RVT RESILIENT VINYL TILE
RWD REDWOOD
RWL RAIN WATER LEADER
S SECOND, SOUTH, SANITARY, SEWER,
STRUCTURE
SA SUPPLY AIR
SALV SALVAGE
SAMP SAMPLE
SAN SANITARY SEWER
SAT SUSPENDED ACOUSTICAL TILE
SATC SUSPENDED ACOUSTICAL TILE CEILING
SB SPLASH BLOCK
SBS STYRENE BUTADIEN STYRENE
SBSTR SUBSTRATE
SC SHADING COEFFICIENT OR SOLID CORE
SCH SCHOOL, SCHEDULE
SCHED SCHEDULE
SCHEM SCHEMATIC
SCP SCUPPER
SCRN SCREEN
SCT STRUCTURAL CLAY TILE
SCWD SOLID CORE WOOD DOOR
SD SHOP DRAWINGS, SMOKE DETECTOR,
OR SOAP DISPENSER;
SDG SIDING
SE SOUTHEAST
SECT SECTION
SEG SEGMENT
SEL SELECT
SEP SEPARATE
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SG SUPPLY GRILLE
SGD SLIDING GLASS DOOR
1PH SINGLE PHASE
SGL SINGLE
SH SHEET
SHR SHOWER
SHR HD SHOWER HEAD
SHRD SHOWER DRAIN
SHT SHEET
SHT MTL FL SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SJI STEEL JOIST INSTITUTE
SK SKETCH
SKCP SUSPENDED KEENE'S CEMENT
PLASTER
SKLT SKYLIGHT
SL SLOPE
SLD WDW HORIZONTAL SLIDING WINDOW
SLDG SLIDING
SLNT SEALANT
SM SHEET METAL
SMH SANITARY MODULE
SMK SMOKE
SND SANITARY NAPKIN DISPENSER
SND INS SOUND INSULATION
SNDU SANITARY NAPKIN DISPOSAL UNIT
SP STATIC PRESSURE, SINGLE POLE
SPC SUSPENDED PLASTER CEILING
SPDT SINGLE POLE DOUBLE THROW
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SPST SINGLE POLE SINGLE THROW
SPLY SUPPLY
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SR SUPPLY REGISTER
SS SANITARY SEWER OR SERVICE SINK
SST STAINLESS STEEL
ST STAIRS, STREET, SINGLE THROW
STA STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIF STIFFENER
STL STEEL
STL JST STEEL JOIST
STL LNTL STEEL LINTEL
STL PL STEEL PLATE
STL RF DK STEEL ROOF DECK
STL TB STEEL TUBE
STL TR STEEL TRUSS
STNLS STAINLESS
STOR STORAGE
STR STRINGERS
STRUCT STRUCTURAL
STRUCT STL STRUCTURAL STEEL
SUB SUBSTITUTE
SURF SURFACE
SUP SUPPORT
SUSP SUSPEND
SUSP CLG SUSPENDED CEILING
SV SHEET VINYL
SV B SHEET VINYL BASE
SW SWITCH, SIDE WALK
SWBD SWITCHBOARD
SWDR SWING DOOR
SWGR SWITCH GEAR
SYM SYMBOL
SYNTH SYNTHETIC
SYS SYSTEM
T TREAD, TILE, TOP, TANGENT
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T&M TIME AND MATERIALS
TB THROUGH BOLT OR TOWEL BAR
TC TOP OF CURB
TCA TILE COUNCIL OF AMERICA
TCP TELEPHONE CONTROL PANEL
TEMPERATURE CONTROL PANEL;
TRAFFIC CONTROL PLAN
TD TOWEL DISPENSER
TECH TECHNICAL
TEL TELEPHONE
TEMP TEMPERATURE OR TEMPORARY
TER TERRAZZO
TERM TERMINAL
TH TOTAL HEAD (PUMPS)
THD THREAD
THERM THERMAL
THK THICKNESS
THRES THRESHOLD
THRSLD THRESHOLD
THRU THROUGH
THRUOUT THROUGHOUT
TK BD TACKBOARD
TMPD TEMPERED
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TO TOP OF ___
TO FDN TOP OF FOUNDATION
TOB TOP OF BEAM
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPH TOILET PAPER HOLDER
TR TOWEL RACK, TOP REGISTER
TRANS TRANSOM, TRANSITION
TRANS WD FIN TRANSPARENT WOOD FINISH
TRTD TREATED
TS TENSILE STRENGTH, TUBE STEEL, TOP
OF STEEL, TOP OF STONE, TOP OF
SLAB
TSTAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
U HEAT TRANSFER COEFFICIENT
UC UNDERCUT
UCD UNDERCUT DOOR
UCF UNDER COUNTER FREEZER
UCR UNDER COUNTER REFRIGERATOR
UGE UNDERGROUND ELECTRIC
UGND UNDERGROUND
UGT UNDERGROUND TELEPHONE
UH UNIT HEATER
UL UNDERWRITERS LABORATORIES
ULT ULTIMATE
UNFIN UNFINISH
UNO UNLESS NOTED OTHER WISE
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
UTIL UTILITY
UV ULTRAVIOLET
V VOLT, VENT, VALVE
VA VOLT AMPRE
VAC VACUUM
VAR VARIES
VB VINYL BASE
VC VARNISH CAMBRIC, VITRIFIED CLAY, VA
SUPPLIED & CONTRACTOR INSTALLED
VCT VINYL COMPOSITION TILE, VITRIFIED
CLAY TILE
VEH VEHICLE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VFAT VINYL FACED ACOUSTICAL TILE
VIC VICINITY
VID VIDEO
VIF VERIFY IN FIELD
VNR VENEER
VOC VOLATILE ORGANIC COMPOUND
VOL VOLUME
VOLT VOLTAGE
VP VENEER PLASTER
VPI VERTICAL POINT OF INTERSECTION
VPOC VERTICAL POINT OF CURVE
VPOT VERTICAL POINT OF TANGENT
VR VAPOR RETARDER
VS VENT STACK
VTR VENT THROUGH ROOF
VV VA SUPPLIED & INSTALLED
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
W WIDE, WEST, WIDTH, WASTE, WATER,
WATT, WIRE
W/ WITH
W/O WITHOUT
WA WATT
WARR WARRANTY
WB WET BULB
WBL WOOD BLOCKING
WC WALL COVERING OR WATER CLOSET
WC WL HNG WATER CLOSET, WALL HUNG
WCHR WATER CHILLER
WCL WL MTD WATER COOLER, WALL HUNG
WD WOOD, WINDOW DIMENSION
WDW WINDOW
WF WIDE FLANGE
WFAB WALL FABRIC
WFR WOOD FRAME
WFS WOOD FURRING STRIPS
WH WATER HEATER
WHSE WAREHOUSE
WL WATER LEVEL
WLD WELDED
WM WIRE MESH
WOM WALK OFF MATT
WP WATERPROOFING, WEATHERPROOF
WPD WATER PRESSURE DROP
WPM WATERPROOF MEMBRANE
WR WEATHER RESISTANT
WS WEATHERSTRIP, WASTE STACK, WATER
SURFACE, WATERSTOP
WSCT WAINSCOT
WT WEIGHT
WTB WALL TILE BASE
WTL WALL TILE
WWF WELDED WIRE FABRIC
X BRACE CROSS BRACE
XFMR TRANSFORMER
XPS EXTRUDED POLYSTYRENE BOARD
(INSULATION)
X-STR EXISTING STRUCTURE
YD YARD
YR YEAR
1. ACCESS TO EXISTING FIRE EXIT SHALL REMAIN
OPERATIONAL DURING ALL PHASES OF CONSTRUCTION.
ENSURE ADEQUATE EGRESS CLEARANCES ARE
MAINTAINED AND NOT IMPEDED DURING PHASED
CONSTRUCTION.
2. GENERAL NOTES APPLY TO ALL DRAWING SETS.
3. SUBCONTRACTORS FOR EACH TRADE ARE ADVISED THAT
INFORMATION PERTINENT TO THEIR WORK MAY OCCUR IN
OTHER PORTIONS OF THE CONTRACT DOCUMENTS. ALL
NOTES ARE TO BE REVIEWED AND APPLIED TO RELATED
BUILDING DOCUMENTS.
4. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS.
IF INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS
ARE DISCOVERED FOLLOW PROCEDURES LISTED IN
SECTION 01 26 13 REQUESTS FOR INFORMATION (RFI)
BEFORE AND/OR DURING CONSTRUCTION.
5. CROSS REFERENCES SHOWN ON DRAWINGS DO NOT
NECESSARILY INDICATE ALL LIKE CONDITIONS AND DO NOT
LIMIT APPLICATION OF ANY DRAWING OR DETAIL. WHERE
SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT
CANNOT BE DETERMINED, FOLLOW PROCEDURES LISTED
IN SECTION 01 26 13 REQUESTS FOR INFORMATION (RFI)
PRIOR TO PROCEEDING WITH WORK.
6. REVIEW SPECIFICATIONS FOR INSTRUCTIONS NOT SHOWN
ON DRAWINGS. INFORMATION COMMON TO SEVERAL
DRAWINGS MAY BE NOTED ON ONLY ONCE.
CONTRACTORS ARE RESPONSIBLE FOR ENTIRE SET OF
DOCUMENTS.
7. PATCH ALL HOLES IN EXISTING SURFACES AND WHERE
EQUIPMENT HAS BEEN REMOVED OR DEMOLITION HAS
OCCURRED AND PREPARE WALL SURFACES (PATCH, SKIM
COAT, PAINT AND FINISH TO MATCH ADJACENT SURFACES)
AS REQUIRED IN PREPARATION FOR NEW FINISHES
SCHEDULED. PATCH TO MATCH ADJACENT SURFACES IF
NOT SCHEDULED.
8. DIMENSIONS ARE TO STRUCTURAL GRIDLINE OR FACE OF
FINISHED WALL UNLESS NOTED OTHERWISE.
9. PROVIDE METAL BACKING AND/OR METAL BLOCKING IN
WALLS AS REQUIRED AT ALL WALL-MOUNTED ITEMS.
VERIFY HEIGHT AND LENGTH WITH ACTUAL EQUIPMENT.
REFER TO METAL BACKING AND BLOCKING DETAILS ON
SHEET A-722. AT EXISTING WALLS, REMOVE WALL
MATERIAL TO INSTALL METAL BACKING/BLOCKING FOR
NEW WALL-MOUNTED ITEMS.
10. ALL EXISTING FLOOR AND WALL OPENINGS AND
DEPRESSIONS NOT USED IN THE NEW WORK SHALL BE
FILLED OR CLOSED WITH MATERIALS TO MEET REQUIRED
FIRE RATING AND MATCH ADJACENT FINISHES.
11. DRAWINGS ARE NOT TO BE SCALED. CONTRACTOR TO
VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO
COMMENCING THE WORK.
12. COORDINATE WITH INTERIORS SHEETS FOR CORNER
GUARD AND WALL PROTECTION LOCATIONS AND DETAILS.
13. RADIUS EXPOSED COUNTERTOP CORNERS 2" RADIUS,
TYPICALLY. (2" WHERE 3MM EDGE BANDING, 1" RADIUS AT
PLAM EDGES.) SEE CASEWORK DETAILS.
14. CAULK ALL COUNTERTOPS, BACKSPLASHES AND CABINETS
AT LOCATIONS WHERE THEY MEET WALLS. SEAL ALL CUT-
OUTS IN COUNTERTOPS.
15. ALL CUTTING AND PATCHING REQUIRED FOR NEW
MECHANICAL AND ELECTRICAL WORK IN ALL EXISTING
SPACES SHALL BE BY THE RESPECTIVE CONTRACTORS.
16. MATCH ALL FINISHED WALL THICKNESS WHERE NEW
WALLS OCCUR IN LINE WITH EXISTING WALLS.
17. CONTRACTOR TO PROVIDE FIRE, SMOKE, DIRT, DUST &
NOISE CONTAINMENT BARRIERS BETWEEN THE WORK
AREA & THE ADJACENT OCCUPIED SPACES.
18. ALL PIPING, CONDUITS, AND RELATED MECHANICAL AND
ELECTRICAL ITEMS SHALL BE CONCEALED WITHIN
DRYWALL AND/OR PLASTER FURRING AS REQUIRED IN
FINISHED AREAS WHETHER SHOWN ON DRAWINGS OR NOT
UNLESS OTHERWISE NOTED.
19. SEAL AROUND ALL MECHANICAL AND ELECTRICAL
EQUIPMENT PENETRATIONS AT RATED WALLS, ABOVE AND
BELOW CEILINGS, WITH A UL APPROVED FIRE-STOPPING
MATERIAL.
20. ALL INTERIOR WALLS WILL BE TYPE 'S' CONSTRUCTION
UNLESS OTHERWISE INDICATED. ALL FRAMING AROUND
COLUMNS WILL BE TYPE 'L2' CONSTRUCTION UNLESS
OTHERWISE INDICATED. REFER TO REGULATORY PLAN
SHEETS GI001 FOR WALL RATINGS.
21. WHEN WALL PARTITIONS OF DIFFERENT FIRE RATING
INTERSECT, THE HIGHEST RATED PARTITION TAKES
PRECEDENT.
22. ALL EXISTING TO REMAIN CEILING AND WALL GRILLES,
DIFFUSERS AND LIGHTS, SPRINKLER HEADS, OCCUPANCY
AND FIRE ALARM DETECTORS TO BE CLEANED IN AREAS
OF CONSTRUCTION.
23. VERIFY THAT THE EXISTING WALLS REQUIRING FIRE
RATING ARE MAINTAINED, REPAIRED AND EXTENDED TO
STRUCTURE.
24. REFER TO LIFE SAFETY PLANS AND FLOOR PLANS FOR
LOCATION OF REQUIRED WALL RATINGS.
25. ALL THERMOSTAT LOCATIONS TO BE COORDINATED WITH
COR PRIOR TO INSTALLATION.
GENERAL SHEET NOTES:
Revisions: Date:
07/26/2022
UP
DN
DN
DN
DN
DN
UP
DEPARTMENT LEGEND
ALL RESIDENT SPACES
CIRCULATION
FEMALE RESIDENT
SPACES
MALE RESIDENT SPACES
PUBLIC
STAFF
UTILITY
M A
IN
E
S T
R E
E T
C O
R R
ID
O
R
CORRIDOR
A-131
ACTUAL: 416 SF
PROG: 0 SF
STAIR 2
S2-1
ACTUAL: 124 SF
PROG: 0 SF
STAFF
BREAK
A-109
ACTUAL: 190 SF
PROG: 120 SF
OFFICE 3
A-111
ACTUAL: 81 SF
PROG: 100 SF
STAFF
TLT
A-110
ACTUAL: 64 SF
PROG: 60 SF
OFFICE 2
A-113
ACTUAL: 104 SF
PROG: 100 SF
OFFICE 1
A-112
ACTUAL: 83 SF
PROG: 100 SF
SHARED
LAUNDRY
A-114
ACTUAL: 185 SF
PROG: 150 SF WOMEN'S
LOUNGE
A-116
ACTUAL: 224 SF
PROG: 400 SF
FAMILY
VISITATION
A-117
ACTUAL: 236 SF
PROG: 0 SF
STAIR 1
S1-1
ACTUAL: 187 SF
PROG: 0 SF
VESTIBULE
A-100
ACTUAL: 148 SF
PROG: 0 SF
WAITING
A-101
ACTUAL: 663 SF
PROG: 160 SF
RECEPTION
A-102
ACTUAL: 103 SF
PROG: 160 SF
REC
ROOM &
KITCHEN
A-103
ACTUAL: 857 SF
PROG: 0 SF
PUBLIC
TLT
A-104
ACTUAL: 65 SF
PROG: 60 SF
ELEVATOR
A-001
ACTUAL: 89 SF
PROG: 0 SF
UDS TLT
A-105
ACTUAL: 72 SF
PROG: 60 SF
EXAM RM
A-106
ACTUAL: 117 SF
PROG: 125 SF
MULTIPURPOSE
A-107
ACTUAL: 212 SF
PROG: 200 SF
MULTIPURPOSE
A-108
ACTUAL: 210 SF
PROG: 200 SF
CORRIDOR
A-130
ACTUAL: 180 SF
PROG: 0 SF
MEN'S
LOUNGE
A-115
ACTUAL: 331 SF
PROG: 400 SF TELECOM
ROOM
A-119
ACTUAL: 93 SF
PROG: 100 SF
HAC
A-118
ACTUAL: 70 SF
PROG: 70 SF
FIRE
RISER
ROOM
A-120
ACTUAL: 74 SF
PROG: 0 SF
CLOSET
A-101A
ACTUAL: 31 SF
PROG: 0 SF
D1
D2
PROGRAM SYMBOLS
UN-RATED PARTITION
SMOKE PARTITION
1 HOUR RATED PARTITION
1 HOUR RATED SMOKE PARTITION
DEPARTMENT LEGEND
BARIATRIC RESIDENT
ROOM
CIRCULATION
FEMALE RESIDENT
SPACES
MALE RESIDENT SPACES
STAFF
UTILITY
M A
IN
E
S T
R E
E T
C O
R R
ID
O
R B
E L
O W
STAIR 1
S2-1
ACTUAL: 189 SF
PROG: 0 SF
CORRIDOR
A-250
ACTUAL: 620 SF
PROG: 0 SF
UNIT 3
A-216
ACTUAL: 159 SF
PROG: 130 SF
SHARED
BATH
A-217
ACTUAL: 101 SF
PROG: 70 SF
SHARED
BATH
A-214
ACTUAL: 102 SF
PROG: 70 SF
UNIT 4
A-215
ACTUAL: 139 SF
PROG: 130 SF
UNIT 5
A-213
ACTUAL: 140 SF
PROG: 130 SF
UNIT 6
A-212
ACTUAL: 167 SF
PROG: 130 SF
UNIT 2
A-221
ACTUAL: 144 SF
PROG: 130 SF
UNIT 1
A-222
ACTUAL: 173 SF
PROG: 130 SF
SHARED
BATH
A-223
ACTUAL: 101 SF
PROG: 70 SF
SHARED
BATH
A-205
ACTUAL: 89 SF
PROG: 70 SF
SHARED
BATH
A-208
ACTUAL: 89 SF
PROG: 70 SF
PRIVATE
BATH
A-211
ACTUAL: 88 SF
PROG: 70 SF
UNIT 11
A-203
ACTUAL: 124 SF
PROG: 130 SF
UNIT 10
A-204
ACTUAL: 124 SF
PROG: 130 SF
UNIT 9
A-206
ACTUAL: 116 SF
PROG: 130 SF
UNIT 8
A-207
ACTUAL: 135 SF
PROG: 130 SF
UNIT 7
A-209
ACTUAL: 120 SF
PROG: 130 SF
LOGISTICS
SUPPLY
A-210
ACTUAL: 126 SF
PROG: 130 SF
BARIATRIC
BATH
A-202A
ACTUAL: 91 SF
PROG: 85 SF
BARIATRIC
UNIT 12
A-202
ACTUAL: 180 SF
PROG: 160 SF
STAIR 2
S2-2
ACTUAL: 149 SF
PROG: 0 SF
LINEN &
SUPPLY
STOR.
A-201
ACTUAL: 121 SF
PROG: 70 SF
NURSE
STATION
A-226
ACTUAL: 163 SF
STAFF
TLT
A-225
ACTUAL: 54 SF
PROG: 60 SF
ELEVATOR
A-002
ACTUAL: 89 SF
PROG: 0 SF
HAC
A-224
ACTUAL: 87 SF
PROG: 70 SF
MED
ROOM
A-227
ACTUAL: 115 SF
PROG: 80 SF
SECURE
CORRIDOR
A-220
95 SF
TELECOM
ROOM
A-219
ACTUAL: 93 SF
PROG: 100 SF
SOILED
UTILITY
A-419
ACTUAL: 98 SF
PROG: 70 SF
CORRIDOR
A-252
ACTUAL: 322 SF
PROG: 0 SF
CORRIDOR
A-251
ACTUAL: 603 SF
PROG: 0 SF
UTILITY
ACCESS
A-421
ACTUAL: 77 SF
PROG: 0 SF
UTILITY
CHASE
A-422
ACTUAL: 33 SF
PROG: 0 SF
D1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
TRIPLE C - The A/E Group 100 Pearl Street, 14th floor Hartfort, CT 06103
(315) 484-5958 Mat Perkins
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP
MES GROUP
550 North Reo St. Suite 203 Tampa, FL 33609
(813) 289-4700 Nicholas Stephensen, P.E.
STRUCTURAL
C&S Companies 2575 E Camelback Rd, Suite 740 Phoenix, AZ 85016
(602) 997-7536 Bryan K. Salt, P.E. S.E.
B
IM
/4
-3
C o n s tr u c t S u b s ta n c e
U s e
R e s id e n ti a l R e h a b
B u ild in g /4
-3
.A u g u s ta
.A rc h .r v t
/2
/2
:0
:5
A
M
A-002
PROGRAM FLOOR PLANS 402-318
BLDG 258
07/26/2022 M.PERKINS K.MACAULAY
100% CONSTRUCTION
DOCUMENTS
ISSUED FOR BIDDING
Construct Substance Use Residential Rehab
1 VA Center, Augusta, Maine
1/8" = 1'-0" F2
PROGRAM FLOOR PLAN - FIRST FLOOR
PROJECT SQUARE
FOOTAGES- PHASE 1
ROOM PROGRAM SCHEDULE - FIRST FLOOR
LEGEND NAME
ROOM PROGRAM
CODE
PROGRAM
AREA
ACTUAL
AREA
AREA
DIFFERENCE
UTILITY CHASE 41 SF
ELEC CLOSET 20 SF
CLOSET 15 SF
H20 3 SF
ALL RESIDENT SPACES
REC ROOM & KITCHEN DAYR1 0 SF 857 SF -857 SF
FAMILY VISITATION RAMR1 0 SF 236 SF -236 SF
SHARED LAUNDRY NULR1 150 SF 185 SF -35 SF
MULTIPURPOSE IPK01 200 SF 210 SF -10 SF
MULTIPURPOSE IPK01 200 SF 212 SF -12 SF
UDS TLT TNPG1 60 SF 72 SF -12 SF
CIRCULATION
CORRIDOR 0 SF 416 SF -416 SF
STAIR 1 0 SF 187 SF -187 SF
ELEVATOR 0 SF 89 SF -89 SF
STAIR 2 0 SF 124 SF -124 SF
CORRIDOR 0 SF 180 SF -180 SF
CORRIDOR 0 SF 239 SF -239 SF
CORRIDOR 0 SF 114 SF -114 SF
CORRIDOR 0 SF 502 SF -502 SF
CORRIDOR 0 SF 76 SF -76 SF
FEMALE RESIDENT SPACES
WOMEN'S LOUNGE DAYR1 400 SF 224 SF 176 SF
MALE RESIDENT SPACES
MEN'S LOUNGE DAYR1 400 SF 331 SF 69 SF
PUBLIC
VESTIBULE 0 SF 148 SF -148 SF
WAITING RCP02 160 SF 663 SF -503 SF
PUBLIC TLT TNPG1 60 SF 65 SF -5 SF
STAFF
RECEPTION RCP02 160 SF 103 SF 57 SF
OFFICE 3 OFA09 100 SF 81 SF 19 SF
EXAM RM TRGM1 125 SF 117 SF 8 SF
OFFICE 1 OFA09 100 SF 83 SF 17 SF
OFFICE 2 OFA09 100 SF 104 SF -4 SF
STAFF BREAK OFA07 120 SF 190 SF -70 SF
STAFF TLT TNPG1 60 SF 64 SF -4 SF
UTILITY
TELECOM ROOM 100 SF 93 SF 7 SF
HAC 70 SF 70 SF 0 SF
FIRE RISER ROOM 0 SF 74 SF -74 SF
CLOSET 0 SF 31 SF -31 SF
FIRST FLOOR 6223 SF
Grand total: 35 6223 SF
1/8" = 1'-0" C2
PROGRAM FLOOR PLAN - SECOND FLOOR
ROOM PROGRAM SCHEDULE - SECOND FLOOR
legend NAME
ROOM
PROGRAM
CODE
PROGRAM
AREA
ACTUAL
AREA
AREA
DIFFERENCE
BARIATRIC RESIDENT ROOM
BARIATRIC BATH TSPB1 85 SF 91 SF -6 SF
BARIATRIC UNIT 12 BRNP1 160 SF 180 SF -20 SF
CIRCULATION
STAIR 1 --- 0 SF 189 SF -189 SF
CORRIDOR --- 0 SF 620 SF -620 SF
STAIR 2 --- 0 SF 149 SF -149 SF
ELEVATOR --- 0 SF 89 SF -89 SF
CORRIDOR --- 0 SF 603 SF -603 SF
CORRIDOR --- 0 SF 322 SF -322 SF
FEMALE RESIDENT SPACES
UNIT 2 BRUN1 130 SF 144 SF -14 SF
UNIT 1 BRUN1 130 SF 173 SF -43 SF
SHARED BATH TSPG1 70 SF 101 SF -31 SF
SECURE CORRIDOR --- 0 SF 95 SF -95 SF
MALE RESIDENT SPACES
UNIT 3 BRUN1 130 SF 159 SF -29 SF
SHARED BATH TSPG1 70 SF 101 SF -31 SF
SHARED BATH TSPG1 70 SF 102 SF -32 SF
UNIT 4 BRUN1 130 SF 139 SF -9 SF
UNIT 5 BRUN1 130 SF 140 SF -10 SF
UNIT 6 BRUN1 130 SF 167 SF -37 SF
SHARED BATH TSPG1 70 SF 89 SF -19 SF
SHARED BATH TSPG1 70 SF 89 SF -19 SF
PRIVATE BATH TSPG1 70 SF 88 SF -18 SF
UNIT 11 BRUN1 130 SF 124 SF 6 SF
UNIT 10 BRUN1 130 SF 124 SF 6 SF
UNIT 9 BRUN1 130 SF 116 SF 14 SF
UNIT 8 BRUN1 130 SF 135 SF -5 SF
UNIT 7 BRUN1 130 SF 120 SF 10 SF
STAFF
STAFF TLT TNPG1 60 SF 54 SF 6 SF
NURSE STATION OFA07 163 SF
MED ROOM MEDP1 80 SF 115 SF -35 SF
UTILITY
LOGISTICS SUPPLY LCCL1 130 SF 126 SF 4 SF
LINEN & SUPPLY STOR. LCCL1 70 SF 121 SF -51 SF
HAC JANC1 70 SF 87 SF -17 SF
TELECOM ROOM COMC1 100 SF 93 SF 7 SF
SOILED UTILITY LCCL1 70 SF 98 SF -28 SF
UTILITY ACCESS LCCL1 0 SF 77 SF -77 SF
UTILITY CHASE LCCL1 0 SF 33 SF -33 SF
SECOND FLOOR 5416 SF
Grand total: 36 5416 SF
PROJECT SQUARE
FOOTAGES - PHASE 1
FIRST FLOOR:
NET SQUARE FEET (NSF) - 6,226 NSF
GROSS SQUARE FEET (GSF) - 6,379 GSF
SECOND FLOOR:
NET SQUARE FEET (NSF) - 5,416 NSF
GROSS SQUARE FEET (GSF) - 6,401 GSF
PROJECT TOTAL:
NET SQUARE FEET (NSF) - 11,647 NSF
GROSS SQUARE FEET (GSF) - 12,780 GSF
UNCONDITIONED PENTHOUSE:
GROSS SQUARE FEET (GSF) - 2,654 GSF
FIRST FLOOR:
NET SQUARE FEET (NSF) - 6,226 NSF
GROSS SQUARE FEET (GSF) - 6,379 GSF
SECOND FLOOR:
NET SQUARE FEET (NSF) - 5,416 NSF
GROSS SQUARE FEET (GSF) - 6,401 GSF
PROJECT TOTAL:
NET SQUARE FEET (NSF) - 11,647 NSF
GROSS SQUARE FEET (GSF) - 12,780 GSF
UNCONDITIONED PENTHOUSE:
GROSS SQUARE FEET (GSF) - 2,654 GSF
DEDUCTIVE ALTERNATES
D1
DEDUCTIVE ALTERNATE #1: REMOVE ALL SCOPE OF WORK ASSOCIATED
WITH ENCLOSING THE CONNECTING CORRIDOR A-131, INCLUDING THE
WALLS, WINDOW, CEILING, AND ROOF. THE RAISED CONCRETE SLAB AND
SUPPORTING WALLS SHALL REMAIN AND PROVIDE AN OUTSIDE
CONNECTION TO MAINE STREET. (~889 SF)
D2
DEDUCTIVE ALTERNATE #2: REMOVE ALL SCOPE OF WORK ASSOCIATED
WITH FINISHING OUT MEN'S LOUNGE ROOM A-115, WOMEN'S LOUNGE A-116,
AND FAMILY VISITATION A-117. PROVIDE STORAGE SPACE ONLY. (~813 SF)
NOTE: DEDUCTIVE ALTERNATES ARE CASCADING. EACH DEDUCT WILL BE TAKEN IN
SUCCESSION AND SHALL BE PRICED UNDER SEQUENTIAL, SEPARATE CLINs
(CONTRACT LINE ITEM NUMBER) SO DETERMINATIONS CAN BE MADE AND
PRIORITIES ESTABLISHED BASED ON BIDS RECEIVED.
DN
DN
DN
UP
UP
DN
DN
ARCHITECTURAL SYMBOL LEGEND
GENERAL SHEET NOTES
KEY PLAN
A. CONTRACTOR TO COORDINATE WITH ROOF INSTALLATION WARRANTY
REQUIREMENTS FOR ANY MODIFICATIONS TO ROOFING TO ENSURE NO
VIOLATIONS OCCUR OF THE WARRANTY. CONTRACTOR TO EMPLOY A
CERTIFIED ROOFING INSPECTOR MEETING THE REQUIREMENTS OF THE
INSTALLED ROOF. ALL WARRANTY VIOLATIONS WILL BE REQUIRED TO BE
CORRECTED PRIOR TO CLOSE OUT.
B. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE
RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA.
PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT
WALLS SHALL BE CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY
MEANS OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL. SEE
MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
C. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND CONDUIT
PIPING WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND
SHALL PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO
MAINTAIN REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
D. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD
VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM
THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN ADVANCE THE
LOCATION AND CONDITION OF THOSE EXISTING SYSTEMS SHOWN TO BE
MODIFIED OR REMOVED. CONTRACTOR TO NOTIFY ARCHITECT SHOULD
CONDITIONS BE FOUND TO DIFFER SIGNIFICANTLY FROM CONSTRUCTION
DOCUMENTS.
E. CONTRACTOR TO COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL
TRADES PRIOR TO INSTALLATION.
F. CONTRACTOR TO PROVIDE GALVANIC PROTECTION AS REQUIRED AT
CONNECTIONS BETWEEN ALL DISSIMILAR METALS.
G. ANY FLOOR, WALL, OR CEILING CUTTING OR FILLING THAT IS REQUIRED TO
COMPLETE THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT
AND RETURN TO MATCH EXISTING CONDITIONS AND FINISHES.
H. CONTRACTOR TO PROVIDE ESCUTCHEONS ON ALL NEW EXPOSED EXTERIOR
PIPE PENETRATIONS AND SEAL COMPLETELY.
I. CONTRACTOR TO PROVIDE TEMPORARY FLOORING WHILE MODIFYING
SUBFLOORING.
J. ANY LANDSCAPE, HARDSCAPE, FIXTURE, SIGNAGE AND SYSTEMS OR
PEDESTRIAN CONTROL DEVICES WITHIN THE TEMPORARY ACCESSIBLE
PATHWAY SHALL BE PROTECTED IN PLACE OR TEMPORARILY RELOCATED AS
NECESSARY FOR CONTINUED UNINTERRUPTED OPERATION,
ACCESS, MAINTENANCE AND / OR VISIBILITY.
INTERIOR STUD FRAMED WALL. SEE WALL TYPES
AREA OF NO WORK, FACILITY TO REMAIN OPERATIONAL
PROPOSED EXTERIOR WALL. SEE WALL SECTIONS
VA/VA ITEM - VA SUPPLIED & INSTALLED
VA/CC OR VC ITEM - VA SUPPLIED & CONTRACTOR
INSTALLED
CC/CC ITEM - CONTRACTOR SUPPLIED & INSTALLED
FURNITURE, FIXTURE, & EQUIPMENT INDICATORA1000
MATCHLINE
1 HR FIRE AND SMOKE BARRIER
2 HR FIRE AND SMOKE BARRIER
SMOKE RATED PARTITION / SMOKE BARRIER /
COMPARTMENT
1 HR FIRE RATED PARTITION
2 HR FIRE RATED PARTITION
EXPANSION JOINT
DEDUCTIVE ALTERNATE
FOUNDATION DRAIN - SEE CIVIL
KEYNOTES#
C1
A-301
C1
A-301
F4
A-301
F4
A-301
'-8
A-201
F6
A-201
F2
8' -2
/2
4 4
A
A
B
B
C
C
D
D E
E
STAIR 2
S2-1
124 SF
STAFF
BREAK
A-109
190 SF
STAFF
TLT
A-110
64 SF
OFFICE 3
A-111
81 SF
OFFICE 2
A-113
104 SF
OFFICE 1
A-112
83 SF
MULTIPURPOSE
A-108
210 SF
MULTIPURPOSE
A-107
212 SF
EXAM RM
A-106
117 SF
UDS TLT
A-105
72 SF
REC
ROOM &
KITCHEN
A-103
857 SF
PUBLIC
TLT
A-104
65 SF
ELEVATOR
A-001
89 SF
RECEPTION
A-102
103 SF
WAITING
A-101
663 SF
VESTIBULE
A-100
148 SF
STAIR 1
S1-1
187 SF
FAMILY
VISITATION
A-117
236 SF
WOMEN'S
LOUNGE
A-116
224 SF
MEN'S
LOUNGE
A-115
331 SF
SHARED
LAUNDRY
A-114
185 SF
1'-7 3/8" 14'-0"
1'-10"
7'-8" 23'-0" 20'-2" 24'-3"
1'-10"
17'-5 3/8" 76'-11" 21'-2"
CORRIDOR
A-131
416 SF
23'-6" 23'-0" 20'-2" 24'-3"
TELECOM
ROOM
A-119
93 SF
HAC
A-118
70 SF
FIRE
RISER
ROOM
A-120
74 SF
CLOSET
A-101A
31 SF
0.50.5
A.5
1' -1
0"
'-7
'-9
'-3
1'-10" 1'-10"
82'-5 7/8" 94'-7" 21'-2" SITE RAMP AND ENTRY STAIRS
1' -1
0"
'-3
7'
-3
'-8
8'
-1 0"
'-7
7'
-0 " 1'
-1 1"
S
IT
E S
T A
IR
5' -8
/4
O V
E R
A
LL
B U
IL
D
IN
G
'-3
U T
IL
IT
Y T
O W
E R
7' -1
B
A T
H R
O O
M
± 82'-8 1/2" 94'-4 3/8" 21'-2"
'-4
'-8
'-4
'-4
O
V E
R A
LL
7' -3
/8
46'-9 3/8" FUTURE EXPANSION FOOTPRINT 49'-2 1/4" 10'-6 1/2" 34'-10 1/4"
1' -8
'-0
'-7
MATCHLINE
SEE: F2/A-101B
MATCHLINE
SEE: F1/A-101A
CORRIDOR
A-130
180 SF
131B 131A
S 2-
107 103B
3A
S 1-
A
1A
101 100
S 1-
A-403
D8
A-403
E8 A-402
A8
A-402
A3
A-403
B7
A-402
E8
A-402
F3CORRIDOR
A-133
502 SF
CORRIDOR
A-132
114 SF
F E
C
UTILITY
CHASE
A-425A-425
A-450
D1
A-450
F1
A-451
B1
A-451
F1
ELEC
CLOSET
A-130AA-130A
CLOSET
A-130BA-130B
S A
-1
0B
0A CORRIDOR
A-134
76 SF
A-201
D3
A-201
B3
D1
D2
130C
FECA-601
FEC
STAIR 2
S2-1
124 SF
STAFF
BREAK
A-109
190 SF
STAFF
TLT
A-110
64 SF
OFFICE 3
A-111
81 SF
OFFICE 2
A-113
104 SF
OFFICE 1
A-112
83 SF
MULTIPURPOSE
A-108
210 SF
MULTIPURPOSE
A-107
212 SF
EXAM RM
A-106
117 SF
UDS TLT
A-105
72 SF
REC
ROOM &
KITCHEN
A-103
857 SF
PUBLIC
TLT
A-104
65 SF
ELEVATOR
A-001
89 SF
RECEPTION
A-102
103 SF
WAITING
A-101
663 SF
VESTIBULE
A-100
148 SF
STAIR 1
S1-1
187 SF
SHARED
LAUNDRY
A-114
185 SF
TELECOM
ROOM
A-119
93 SF
HAC
A-118
70 SF
FIRE
RISER
ROOM
A-120
74 SF
CLOSET
A-101A
31 SF
CORRIDOR
A-130
180 SF
131A
S 2-
107 103B
3A
S 1-
A
1A
101 100
S 1-
CORRIDOR
A-133
502 SF
CORRIDOR
A-132
114 SF
F E
C
UTILITY
CHASE
A-425A-425
ELEC
CLOSET
A-130AA-130A
CLOSET
A-130BA-130B
S A
-1
0B
0A
CORRIDOR
A-134
76 SF
B8
A-101
D1
D2
130C
A-601
RAISED WALKWAY
FLOOR
42" GUARD RAIL
EACH SIDE
NEW HM DOOR
AND FRAME
EXISTING WALL
NEW RETENTION
WALL AND
FOUNDATION
A-451
E5
EXISTING BRICK
HEADER TO REMAIN
N
AREA B
KEY PLAN
AREA A
WORK AREA
EXISTING BUILDING
EXISTING BUILDING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
TRIPLE C - The A/E Group 100 Pearl Street, 14th floor Hartfort, CT 06103
(315) 484-5958 Mat Perkins
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP
MES GROUP
550 North Reo St. Suite 203 Tampa, FL 33609
(813) 289-4700 Nicholas Stephensen, P.E.
STRUCTURAL
C&S Companies 2575 E Camelback Rd, Suite 740 Phoenix, AZ 85016
(602) 997-7536 Bryan K. Salt, P.E. S.E.
B
IM
/4
-3
C o n s tr u c t S u b s ta n c e
U s e
R e s id e n ti a l R e h a b
B u ild in g /4
-3
.A u g u s ta
.A rc h .r v t
/2
/2
:1
:0
A
M
A-101
ARCHITECTURAL FLOOR PLAN - FIRST FLOOR 402-318
BLDG 258
07/26/2022 M.PERKINS C. LOWERY
100% CONSTRUCTION
DOCUMENTS
ISSUED FOR BIDDING
Construct Substance Use Residential Rehab
1 VA Center, Augusta, Maine
1/8" = 1'-0" F1
ARCHITECTURAL FLOOR PLAN - FIRST FLOOR
1 BUILDING EXPANSION JOINT
2 NEW MANUAL OPERABLE PARTITION
3 DEDUCTIVE ALTERNATE #1: PROVIDE RAISED EXTERIOR CONCRETE WALK-WAY
IN LIEU OF ENCLOSED CORRIDOR.
4 NEW EXTERIOR DOOR IN EXISTING CORRIDOR WALL, MODIFY WALL
CONSTRUCTION AS REQUIRED.
5 DEDUCTIVE ALTERNATE #2: REMOVE ALL SCOPE OF WORK ASSOCIATED WITH
FINISH OUT MEN'S LOUNGE ROOM A-115, WOMENS LOUNGE A-116, AND FAMILY
VISITATION A-117. PROVIDE STORAGE SPACE ONLY.
1/8" = 1'-0" C1
ARCHITECTURAL FLOOR PLAN - FIRST FLOOR - DEDUCTIVE ALTERNATES
DEDUCTIVE ALTERNATES
D1
DEDUCTIVE ALTERNATE #1: REMOVE ALL SCOPE OF WORK ASSOCIATED
WITH ENCLOSING THE CONNECTING CORRIDOR A-131, INCLUDING THE
WALLS, WINDOW, CEILING, AND ROOF. THE RAISED CONCRETE SLAB AND
SUPPORTING WALLS SHALL REMAIN AND PROVIDE AN OUTSIDE
CONNECTION TO MAINE STREET. (~889 SF)
D2
DEDUCTIVE ALTERNATE #2: REMOVE ALL SCOPE OF WORK ASSOCIATED
WITH FINISHING OUT MEN'S LOUNGE ROOM A-115, WOMEN'S LOUNGE A-116,
AND FAMILY VISITATION A-117. PROVIDE STORAGE SPACE ONLY. (~813 SF)
NOTE: DEDUCTIVE ALTERNATES ARE CASCADING. EACH DEDUCT WILL BE TAKEN IN
SUCCESSION AND SHALL BE PRICED UNDER SEQUENTIAL, SEPARATE CLINs
(CONTRACT LINE ITEM NUMBER) SO DETERMINATIONS CAN BE MADE AND
PRIORITIES ESTABLISHED BASED ON BIDS RECEIVED.
3/16" = 1'-0" B8
WALKWAY SECTION - DED ALT #1
C1
A-301
C1
A-301
A-201
F2
'-8
131B
HW-12C
A-501
F6
A-501
B8
C1
A-352
F1
A-352
F3
A-352
M A
T C
H
LI
N E
S
E : F
2/ A
-1
B M
A T
C H
LI
E
: F 2/
A -1
B
4 4
A
A
B
B
0.50.5
A.5
A-450
D1
STAIR 2
S2-1
124 SF
MEN'S
LOUNGE
A-115
331 SF
SHARED
LAUNDRY
A-114
185 SF
CORRIDOR
A-130
180 SFCORRIDOR
A-131
416 SF
OFFICE 2
A-113
104 SF
OFFICE 1
A-112
83 SF
OFFICE 3
A-111
81 SF
STAFF
BREAK
A-109
190 SF
STAFF
TLT
A-110
64 SF
A-402
E8
1'-10" 23'-6"
5'-0" 3'-0 7/8" 4'-0" 5'-4" 4'-0" 5'-3 7/8"
25'-4"
A-403
B7
1' -1
1" 7'
-0
'-7
9'
-6
/8
T O
F .O
. S T
U D
9' -3
/4
F
.O . S
T U
D
7' -1
1/
8"
'-3
1' -1
0"
'-4
O
V E
R A
LL
1'-10 1/2" 10'-10" 3'-2" 1'-10"
17'-8 1/2"
12'-8 1/2" 5'-0"
1' -1
1" 5'
-2
1' -1
0"
7' -3
/8
5' -0
'-4
A T
C O
R R
ID
O
R
'-8
E
X T
E R
IO
R
F .O
. W A
LL
'-4
C
LE
A R
W
ID
T H
8' -2
/2
C
O R
R
ID
O R
W1 W1
1'-0" 4'-0" 2'-8" 1'-7 1/2"
W1 W1
7' -1
1/
4" 1'
-3
'-4
5'
-7
/4
3/
4"
'-0
/4
9'
-1
1/ 4"
5' -9
/8
6'
-0
/4
'-2
/4
7 1/4" 22'-6" 1'-0"
7 1/4" 16'-11" 5'-7" 1'-0"
6 3/4"8'-8 1/4"5'-5 1/2"9'-4 1/4" 7 1/4"
10"
6'-2" 7'-9 3/4" 8'-8 1/4" 6 3/4"
7 1/4"
3'-5 3/8" 10'-6 5/8"
7 1/4"
W6 W6
A
A6 11
H W
-R
HW-R1
131A
HW-SH-9
HW-3G
HW-3G
S 2-
H
W -S
H -4
HW-3G
H W
-2 G
A
J4
J4
J4
A4
J4
J4
J4
J4
J4
J4
A6
A
A
A4
J4
J4
A
J4
A6
A
A
A4
A6
A
A 8 A6
A6
A 6 A4
J4
J4
J4 J4
J4
J4
J4
A4
± 82'-4 7/8"
S A
-1
CORRIDOR
A-133
502 SF
1' -0
1'-1"
ELEC
CLOSET
A-130AA-130A
CLOSET
A-130BA-130B
0B
H W
-5 B
0A
H W
-5 D
UTILITY
CHASE
A-425
41 SF
A-201
D3
A-201
B3
A4
A
H1H1H1
H1 H1 H1 H1
A-201
F2
H1
130C
HW-12C
FECA
A
A-201
D3
REMOVE WALL AS
REQUIRED FOR NEW WORK
APPROXIMATE EXTERIOR
EDGE OF NEW WORK
CONNECTING CORRIDOR EXTERIOR VIEW DIAGRAM CONNECTING CORRIDOR INTERIOR VIEW DIAGRAM
APPROXIMATE OPENING IN EXTERIOR WALL
MIN.
1'-6"
MIN.
1'-6"
ARCHITECTURAL SYMBOL LEGEND
GENERAL SHEET NOTES
KEY PLAN
A. CONTRACTOR TO COORDINATE WITH ROOF INSTALLATION WARRANTY
REQUIREMENTS FOR ANY MODIFICATIONS TO ROOFING TO ENSURE NO
VIOLATIONS OCCUR OF THE WARRANTY. CONTRACTOR TO EMPLOY A
CERTIFIED ROOFING INSPECTOR MEETING THE REQUIREMENTS OF THE
INSTALLED ROOF. ALL WARRANTY VIOLATIONS WILL BE REQUIRED TO BE
CORRECTED PRIOR TO CLOSE OUT.
B. CONTRACTOR TO VALIDATE AND VERIFY ALL FIRE RATED AND/OR SMOKE
RATED WALLS AND ASSEMBLIES INDICATED ON PLANS IN WORK AREA.
PROVIDE ALL PIPING PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT
WALLS SHALL BE CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY
MEANS OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL. SEE
MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
C. CONTRACTOR SHALL COORDINATE ALL PIPING, PLUMBING, AND CONDUIT
PIPING WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND
SHALL PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO
MAINTAIN REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
D. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD
VERIFICATION WHERE FEASIBLE. ACTUAL CONDITIONS MAY DIFFER FROM
THOSE INDICATED. CONTRACTOR TO FIELD VERIFY IN ADVANCE THE
LOCATION AND CONDITION OF THOSE EXISTING SYSTEMS SHOWN TO BE
MODIFIED OR REMOVED. CONTRACTOR TO NOTIFY ARCHITECT SHOULD
CONDITIONS BE FOUND TO DIFFER SIGNIFICANTLY FROM CONSTRUCTION
DOCUMENTS.
E. CONTRACTOR TO COORDINATE ALL NEW EQUIPMENT LOCATIONS WITH ALL
TRADES PRIOR TO INSTALLATION.
F. CONTRACTOR TO PROVIDE GALVANIC PROTECTION AS REQUIRED AT
CONNECTIONS BETWEEN ALL DISSIMILAR METALS.
G. ANY FLOOR, WALL, OR CEILING CUTTING OR FILLING THAT IS REQUIRED TO
COMPLETE THIS PROJECT, THE CONTRACTOR SHALL PATCH AND PAINT
AND RETURN TO MATCH EXISTING CONDITIONS AND FINISHES.
H. CONTRACTOR TO PROVIDE ESCUTCHEONS ON ALL NEW EXPOSED EXTERIOR
PIPE PENETRATIONS AND SEAL COMPLETELY.
I. CONTRACTOR TO PROVIDE TEMPORARY FLOORING WHILE MODIFYING
SUBFLOORING.
J. ANY LANDSCAPE, HARDSCAPE, FIXTURE, SIGNAGE AND SYSTEMS OR
PEDESTRIAN CONTROL DEVICES WITHIN THE TEMPORARY ACCESSIBLE
PATHWAY SHALL BE PROTECTED IN PLACE OR TEMPORARILY RELOCATED AS
NECESSARY FOR CONTINUED UNINTERRUPTED OPERATION,
ACCESS, MAINTENANCE AND / OR VISIBILITY.
INTERIOR STUD FRAMED WALL. SEE WALL TYPES
AREA OF NO WORK, FACILITY TO REMAIN OPERATIONAL
PROPOSED EXTERIOR WALL. SEE WALL SECTIONS
VA/VA ITEM - VA SUPPLIED & INSTALLED
VA/CC OR VC ITEM - VA SUPPLIED & CONTRACTOR
INSTALLED
CC/CC ITEM - CONTRACTOR SUPPLIED & INSTALLED
FURNITURE, FIXTURE, & EQUIPMENT INDICATORA1000
MATCHLINE
1 HR FIRE AND SMOKE BARRIER
2 HR FIRE AND SMOKE BARRIER
SMOKE RATED PARTITION / SMOKE BARRIER /
COMPARTMENT
1 HR FIRE RATED PARTITION
2 HR FIRE RATED PARTITION
EXPANSION JOINT
DEDUCTIVE ALTERNATE
FOUNDATION DRAIN - SEE CIVIL
KEYNOTES#
℄℄ 10 '-8
8' -2
/2
1'
-2
/4
1' -2
/4
1/ 4"
WINDOW INFILL AREA -
UNKNOWN CONSTRUCTION
3' -0
3'
-0
1' -4
1/ 4"
4' -1
/4
4'
-1
/4
EXISTING WINDOW TO
BE REMOVED
4" 4"
STRUCTURAL CLAY TILE
BRICK VENEER
1' -0
1'
-0
REMOVE WALL STRUCTURE AS
REQUIRED FOR NEW WORK,
MODIFY / REPLACE AS REQUIRED
TO SUPPORT OPENING
EXISTING INTERIOR FINISH TO
REMAIN, PATCH / REPAIR /
REPLACE AS REQUIRED FOR
NEW WORK
IN AREA OF WALL
DEMOLITION; REMOVE
EXISTING STAINLESS STEEL
HANDRAIL
2 1/2"
1/2" 3" SILICONE EXTERIOR EXPANSION JOINT
INTERIOR ALUMINUM 3" EXPANSION JOINT COVER
FLOOR EXPANSION JOINT COVER BELOW
1' -0
3" SILICONE EXTERIOR EXPANSION JOINT
INTERIOR ALUMINUM 3" EXPANSION JOINT COVER
2 1/2" METAL STUD FRAMING W/
GYPSUM WALL-BOARD
A-501
F4
EXISTING TERRAZZO
WALL BASE DIES INTO
NEW GWB
NEW RB-1 WALL BASE
AT NEW GWB
EXISTING TERRAZZO
WALL BASE DIES INTO
NEW GWB
NEW RB-1 WALL BASE
AT NEW GWB
N
KEY PLAN
AREA A
WORK AREA
EXISTING BUILDING
EXISTING BUILDING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
TRIPLE C - The A/E Group 100 Pearl Street, 14th floor Hartfort, CT 06103
(315) 484-5958 Mat Perkins
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP
MES GROUP
550 North Reo St. Suite 203 Tampa, FL 33609
(813) 289-4700 Nicholas Stephensen, P.E.
STRUCTURAL
C&S Companies 2575 E Camelback Rd, Suite 740 Phoenix, AZ 85016
(602) 997-7536 Bryan K. Salt, P.E. S.E.
B
IM
/4
-3
C o n s tr u c t S u b s ta n c e
U s e
R e s id e n ti a l R e h a b
B u ild in g /4
-3
.A u g u s ta
.A rc h .r v t
/2
/2
:1
:1
A
M
A-101A
ARCHITECTURAL ENLARGED PLAN - FIRST
FLOOR PART A
402-318
BLDG 258
07/26/2022 M.PERKINS K.MACAULAY
100% CONSTRUCTION
DOCUMENTS
ISSUED FOR BIDDING
Construct Substance Use Residential Rehab
1 VA Center, Augusta, Maine
1/4" = 1'-0" F1
ARCHITECTURAL ENLARGED PLAN - FIRST FLOOR PART A
1 24" X 60" EXTERIOR ACCESS PANEL
DOOR…