TOWER INSPECTION REPORT

SITE NAME:

FOR:

HEIGHT / TYPE:

DATE:

Ft Riley

Ft. Riley Kansas NEC

7/14/2021

SITE COORDINATES:

FCC ID:

N 39.09528 W -96.7975

Tower Attachment Identification

# Attachment CL Elev (ft) Make Model Type Azimuth Downtilt Tower Leg Mount

Location Feedline size Line Color Code Coax Face

1 Wifi Antenna Left 16 Yagi 150 0 C 1/C 1/2 A/C

2 Wifi Antenna Left 21 Yagi 150 0 C 1/C 1/2 A/C

3 Wifi Antenna Left 22 Yogi 150 0 1/C 1/2 A/C

4 Wifi Antenna Right 26 Yogi 150 0 1/C 1/2 C/A

5 Wifi Antenna Left 29 Yogi 200 0 1/B 1/2 C/A

6 Wifi Antenna Right 31 Yogi 150 0 1/C 1/2 B/C

7 Wifi Antenna Left 36 Yogi 0 1/B 1/2 A/B

8 Omni Antenna Upright Left 38 Omni 0 1/C 1/2 A/B

9 Omni Antenna Upright Right 102 Dipole 0 1/A 1/2 B/C

10 Omni Antenna Upright Left 225 Dipole 0 3/A 1 5/8 B/C

11 Omni Antenna Upright Right 225 Dipole 0 3/A 7/8 A/C

12 Omni Antenna Inverted Left 316 Omni 0 3/B 1 5/8 B/C

13 Omni Antenna Inverted Right 316 Omni 0 3/B 1 5/8 A/B

14 Omni Antenna Upright Left 339 Omni 0 3/A 7/8

15 Omni Antenna Upright Right 339 Omni 0 3/A 1 5/8 A/B

16 Omni Antenna Upright Left 339 Omni 0 3/A 1 5/8 C/A

17 Omni Antenna Inverted Left 373 Omni 0 3/B 1 5/8 B/C

18 Omni Antenna Upright Left 383 Omni 0 3/A 7/8 B/C

19 Omni Antenna Upright Left 386 Omni 0 3/A 7/8 A/C

20 Omni Antenna Upright Right 386 Omni 0 3/A 1 5/8 A/C

Tower Orientation

A

BC

1 – Tower Leg

A B C

2 – Sector Mount

A

B

C

D

3 – Boom Arm

Customer Date

Site

Guy Level Size (in) Horiz. Dist (ft) Azimuth

(deg) Type

Breaking

Strength @

Temp

Existing

Tension (lb) % of BS

Results of

Tension test

TB Gap

80 0.5625 239 310 GP 27,698.60 3,036.25 11.0% Good

160 0.5625 239 310 GP 29,416.74 2,642.48 9.0% Marginal

239 0.5625 239 310 GP 31,021.70 2,586.70 8.3% Marginal

309 0.625 239 310 TSL 38,843.81 3,317.08 8.5% Marginal

309 0.625 239 310 TSR 38,843.81 3,295.71 8.5% Marginal

407 0.5625 239 310 GP 33,024.63 3,378.49 10.2% Good

80 0.5625 239 190 GP 27,927.93 4,088.39 14.6% Marginal

160 0.5625 239 190 GP 29,553.46 3,340.47 11.3% Good

239 0.5625 239 190 GP 31,021.70 3,565.25 11.5% Good

309 0.625 239 190 TSL 38,760.93 4,382.30 11.3% Good

309 0.625 239 190 TSR 38,760.93 4,190.99 10.8% Good

407 0.5625 239 190 GP 32,923.77 3,797.35 11.5% Good

80 0.5625 239 140 GP 27,760.20 3,164.35 11.4% Good

160 0.5625 239 140 GP 29,455.01 2,905.25 9.9% Good

239 0.5625 239 140 GP 31,021.70 2,845.99 9.2% Good

309 0.625 239 140 TSL 38,820.91 3,521.99 9.1% Good

309 0.625 239 140 TSR 38,820.91 3,628.08 9.3% Good

407 0.5625 239 140 GP 32,997.16 3,501.17 10.6% Good

Good 9-12%

Marginal

7% to <9% or

>12% to 15%

Poor <7% or >15%

Ft Riley

Guy Tension Record

Ft. Riley Kansas NEC 7/14/2021

Tower Height / Type 415 Ambient Temp

EIA-222-G section 13.3.2 states that the maximum deviation from the design initial tension shall be (i) ±10% for guys up to and including 1 in. [25mm] in diameter and (ii) ±5% for guys greater than 1in. [25mm] in diameter, of the specified design initial tension at an anchorage, corrected for the ambient temperature. Standard industry practice assumes initial guy design tensions at 10% of cable breaking strength. This chart's GOOD/MARGINAL/FAIL threshold values reflect the guy tensions with respect to 10% of breaking strength. Actual initial design tensions may differ; consult original tower erection drawings for actual design tensions.

Customer Date

Site

Guy Level Size (in) Horiz. Dist

(ft)

Azimuth

(deg) Type

Breaking

Strength @

Temp

FINAL

Tension (lb) % of BS

80 0.5625 239 310 GP 27,698.60

160 0.5625 239 310 GP 29,416.74

239 0.5625 239 310 GP 31,021.70

309 0.625 239 310 TSL 38,843.81

309 0.625 239 310 TSR 38,843.81

407 0.5625 239 310 GP 33,024.63

80 0.5625 239 190 GP 27,927.93

160 0.5625 239 190 GP 29,553.46

239 0.5625 239 190 GP 31,021.70

309 0.625 239 190 TSL 38,760.93

309 0.625 239 190 TSR 38,760.93

407 0.5625 239 190 GP 32,923.77

80 0.5625 239 140 GP 27,760.20

160 0.5625 239 140 GP 29,455.01

239 0.5625 239 140 GP 31,021.70

309 0.625 239 140 TSL 38,820.91

309 0.625 239 140 TSR 38,820.91

407 0.5625 239 140 GP 32,997.16

Good 9-12%

Marginal 7-15%

Poor <7%, >15%

Ft Riley

FINAL TENSIONS

EIA-222-G section 13.3.2 states that the maximum deviation from the design initial tension shall be (i) ±10% for guys up to and including 1 in. [25mm] in diameter and (ii) ±5% for guys greater than 1in. [25mm] in diameter, of the specified design initial tension at an anchorage, corrected for the ambient temperature. Standard industry practice assumes initial guy design tensions at 10% of cable breaking strength. This chart's GOOD/MARGINAL/FAIL threshold values reflect the guy tensions with respect to 10% of breaking strength. Actual initial design tensions may differ; consult original tower erection drawings for actual design tensions. This report is the FINAL tension values after adjustments.

Ft. Riley Kansas NEC

Tower Height / Type 415 Ambient Temp

File details come from the government source that posted it. Updated .