Attachment 4 Tower Inspection (REDACTED) W911RX22Q0044.pdf
PDF 2 MB Posted
- Attached to
- Communication Tower Repair
- Solicitation number
- W911RX-22-Q-0044
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TOWER INSPECTION REPORT
SITE NAME:
FOR:
HEIGHT / TYPE:
DATE:
Ft Riley
Ft. Riley Kansas NEC
7/14/2021
SITE COORDINATES:
FCC ID:
N 39.09528 W -96.7975
Tower Attachment Identification
# Attachment CL Elev (ft) Make Model Type Azimuth Downtilt Tower Leg Mount
Location Feedline size Line Color Code Coax Face
1 Wifi Antenna Left 16 Yagi 150 0 C 1/C 1/2 A/C
2 Wifi Antenna Left 21 Yagi 150 0 C 1/C 1/2 A/C
3 Wifi Antenna Left 22 Yogi 150 0 1/C 1/2 A/C
4 Wifi Antenna Right 26 Yogi 150 0 1/C 1/2 C/A
5 Wifi Antenna Left 29 Yogi 200 0 1/B 1/2 C/A
6 Wifi Antenna Right 31 Yogi 150 0 1/C 1/2 B/C
7 Wifi Antenna Left 36 Yogi 0 1/B 1/2 A/B
8 Omni Antenna Upright Left 38 Omni 0 1/C 1/2 A/B
9 Omni Antenna Upright Right 102 Dipole 0 1/A 1/2 B/C
10 Omni Antenna Upright Left 225 Dipole 0 3/A 1 5/8 B/C
11 Omni Antenna Upright Right 225 Dipole 0 3/A 7/8 A/C
12 Omni Antenna Inverted Left 316 Omni 0 3/B 1 5/8 B/C
13 Omni Antenna Inverted Right 316 Omni 0 3/B 1 5/8 A/B
14 Omni Antenna Upright Left 339 Omni 0 3/A 7/8
15 Omni Antenna Upright Right 339 Omni 0 3/A 1 5/8 A/B
16 Omni Antenna Upright Left 339 Omni 0 3/A 1 5/8 C/A
17 Omni Antenna Inverted Left 373 Omni 0 3/B 1 5/8 B/C
18 Omni Antenna Upright Left 383 Omni 0 3/A 7/8 B/C
19 Omni Antenna Upright Left 386 Omni 0 3/A 7/8 A/C
20 Omni Antenna Upright Right 386 Omni 0 3/A 1 5/8 A/C
Tower Orientation
A
BC
1 – Tower Leg
A B C
2 – Sector Mount
A
B
C
D
3 – Boom Arm
Customer Date
Site
Guy Level Size (in) Horiz. Dist (ft) Azimuth
(deg) Type
Breaking
Strength @
Temp
Existing
Tension (lb) % of BS
Results of
Tension test
TB Gap
80 0.5625 239 310 GP 27,698.60 3,036.25 11.0% Good
160 0.5625 239 310 GP 29,416.74 2,642.48 9.0% Marginal
239 0.5625 239 310 GP 31,021.70 2,586.70 8.3% Marginal
309 0.625 239 310 TSL 38,843.81 3,317.08 8.5% Marginal
309 0.625 239 310 TSR 38,843.81 3,295.71 8.5% Marginal
407 0.5625 239 310 GP 33,024.63 3,378.49 10.2% Good
80 0.5625 239 190 GP 27,927.93 4,088.39 14.6% Marginal
160 0.5625 239 190 GP 29,553.46 3,340.47 11.3% Good
239 0.5625 239 190 GP 31,021.70 3,565.25 11.5% Good
309 0.625 239 190 TSL 38,760.93 4,382.30 11.3% Good
309 0.625 239 190 TSR 38,760.93 4,190.99 10.8% Good
407 0.5625 239 190 GP 32,923.77 3,797.35 11.5% Good
80 0.5625 239 140 GP 27,760.20 3,164.35 11.4% Good
160 0.5625 239 140 GP 29,455.01 2,905.25 9.9% Good
239 0.5625 239 140 GP 31,021.70 2,845.99 9.2% Good
309 0.625 239 140 TSL 38,820.91 3,521.99 9.1% Good
309 0.625 239 140 TSR 38,820.91 3,628.08 9.3% Good
407 0.5625 239 140 GP 32,997.16 3,501.17 10.6% Good
Good 9-12%
Marginal
7% to <9% or
>12% to 15%
Poor <7% or >15%
Ft Riley
Guy Tension Record
Ft. Riley Kansas NEC 7/14/2021
Tower Height / Type 415 Ambient Temp
EIA-222-G section 13.3.2 states that the maximum deviation from the design initial tension shall be (i) ±10% for guys up to and including 1 in. [25mm] in diameter and (ii) ±5% for guys greater than 1in. [25mm] in diameter, of the specified design initial tension at an anchorage, corrected for the ambient temperature. Standard industry practice assumes initial guy design tensions at 10% of cable breaking strength. This chart's GOOD/MARGINAL/FAIL threshold values reflect the guy tensions with respect to 10% of breaking strength. Actual initial design tensions may differ; consult original tower erection drawings for actual design tensions.
Customer Date
Site
Guy Level Size (in) Horiz. Dist
(ft)
Azimuth
(deg) Type
Breaking
Strength @
Temp
FINAL
Tension (lb) % of BS
80 0.5625 239 310 GP 27,698.60
160 0.5625 239 310 GP 29,416.74
239 0.5625 239 310 GP 31,021.70
309 0.625 239 310 TSL 38,843.81
309 0.625 239 310 TSR 38,843.81
407 0.5625 239 310 GP 33,024.63
80 0.5625 239 190 GP 27,927.93
160 0.5625 239 190 GP 29,553.46
239 0.5625 239 190 GP 31,021.70
309 0.625 239 190 TSL 38,760.93
309 0.625 239 190 TSR 38,760.93
407 0.5625 239 190 GP 32,923.77
80 0.5625 239 140 GP 27,760.20
160 0.5625 239 140 GP 29,455.01
239 0.5625 239 140 GP 31,021.70
309 0.625 239 140 TSL 38,820.91
309 0.625 239 140 TSR 38,820.91
407 0.5625 239 140 GP 32,997.16
Good 9-12%
Marginal 7-15%
Poor <7%, >15%
Ft Riley
FINAL TENSIONS
EIA-222-G section 13.3.2 states that the maximum deviation from the design initial tension shall be (i) ±10% for guys up to and including 1 in. [25mm] in diameter and (ii) ±5% for guys greater than 1in. [25mm] in diameter, of the specified design initial tension at an anchorage, corrected for the ambient temperature. Standard industry practice assumes initial guy design tensions at 10% of cable breaking strength. This chart's GOOD/MARGINAL/FAIL threshold values reflect the guy tensions with respect to 10% of breaking strength. Actual initial design tensions may differ; consult original tower erection drawings for actual design tensions. This report is the FINAL tension values after adjustments.
Ft. Riley Kansas NEC
Tower Height / Type 415 Ambient Temp
File details come from the government source that posted it. Updated .