This is a Technical Capability Submittal template for a federal construction contract to renovate interior lighting and flooring at the David Wills House within Gettysburg National Military Park. The template requires offerors to document project experience, contractor qualifications, and biobased product compliance for solicitation 140P4226R0030.

The submittal requests detailed information on referenced projects including project title, location, owner, and a complete contractor list identifying prime and subcontractors with their roles, contract prices (original and final), and performance periods. Offerors must address seven specific project experience questions covering work performed, alignment with solicitation requirements, cost and schedule variances with explanations, problem resolution, and successful means and methods. Personnel resumes must be submitted for key positions, including current role, supervisor information, work experience for the past five years, education summary, and a statement of qualification for the contract. Additionally, offerors must demonstrate prior experience with biobased products by identifying specific products to be used, their biobased content percentages, and relevant contracts from the past two years. The template specifies minimum biobased content requirements across numerous product categories including paints, coatings, adhesives, cleaners, lubricants, and composite panels. This is a 100% small business set-aside contract with a NAICS code of 236220 (Commercial and Institutional Building Construction) and small business size standard of $45 million, with an expected 90-calendar-day performance period.

View the file

Other files for this federal contract opportunity

Other files attached to GETT RENO INTERIOR LIGHTING FLOORING DWH, newest first.
File Type Posted
Sol_140P4226R0030_Amd_0003.pdf PDF
Sol_140P4226R0030_Amd_0002.pdf PDF
Attachment_7_-_140P4226R0030_Past_Performance_Questionnaire_0002.docx DOCX document
Sol_140P4226R0030_Amd_0001.pdf PDF
Attachment_3_-_Wage_Determination__PA20260073.pdf PDF
Attachment_5_-_Certifications_From_Section_K.docx DOCX document
Sol_140P4226R0030.pdf PDF
Attachment_2_-_Drawings_2005_(For_Reference_ONLY).pdf PDF
Attachment_1_-_SOW_DWH_Interior_Lighting_and_Flooring.docx DOCX document
Attachment_6_-_Limitations_on_Subcontracting_compliance_worksheet.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Experience Questionnaire

Submit responses to the questions below that address experience relative to the elements noted under the Project Experience evaluation subfactor in solicitation section L. Limit submittals to the quantity of projects and timeframes required in the solicitation. Expand the response sections shown below as needed to adequately address each question (this questionnaire may be expanded to multiple pages if needed).

Offeror
Company Name

REFERENCED PROJECT INFORMATION

Project Title
Title
Project Location
City, State
Brief Project Description
Description
Project Owner
Company Name
POC:
First & Last Name
Phone:
(XXX) XXX-XXXX

CONTRACTOR LIST

List Contractor(s) whose experience on the referenced project is being submitted for evaluation on this proposed project. If more than one contractor is listed (i.e. prime and subcontractors), provide information specific to that contractor.

Contractor Name
Role on Referenced Project

(Prime or Sub)

Trade
Price

(list for each contractor’s specific work) Performance Period (calendar days) (list for each contractor’s specific work)

Original
Final
Original
Final
Sparky’s Electrical Company
Prime
Prime
$XXX,XXX
$X,XXX,XXX
XX
XX
ABC Plumbing & Heating, Co
Subcontractor
Plumbing & Mechanical
$X,XXX,XXX
$X,XXX,XXX
XXX
XXX

Subcontractor

PROJECT EXPERIENCE QUESTIONS

1. Describe the project work performed by all contractors listed above.

Response

2. Identify which Project Experience elements listed in section L of the solicitation each contractor’s work addresses.

Response

3. Describe & provide reasons for any changes to the original price for the work described in question 2 above.

Response

4. Describe and provide reasons for any changes to the original schedule for the work described in question 2 above.

Response

5. Describe problems, associated with the work described in question 2 above, which were encountered and how they were resolved. Describe how the offeror’s proposal accounts for similar issues.

Response

6. Describe the means and methods, associated with the work described in question 2 above, which were successful. Would you implement the same means and methods on the proposed project? Why or why not?

Response

7. Provide any other additional project information you believe should be presented.

Response

PERSONNEL RESUME TEMPLATE

Employee’s Name:

PROPOSED POSITION TITLE:

SUPERVISOR'S NAME:

CURRENT POSITION WITH THE CONTRACT FIRM:

TIME IN CURRENT POSITION: (Yrs. Mos.)

RESPONSIBLE FOR THE WORK OF: PERSONS

DESCRIPTION OF SCOPE OF CURRENT JOB: (Use attached sheet if necessary)

WORK EXPERIENCE: (Beginning with the most recent for the past 5 years.)

Dates (From – To)
Position or Title
Company Name and Address
Reference and Phone Number

EDUCATION SUMMARY:

Name and Address of Institution
Dates Attended
Diploma or Certificate

High School

College

Technical

Trade Schools

PROVIDE A BRIEF STATEMENT OF WHY THIS PERSON IS BELIEVED TO BE QUALIFIED FOR THIS CONTRACT

140P4226R0030 GETT Renovate David Wills House Interior Lighting and Flooring

SAM Unique Entity ID #:

TIN #:

Biobased Certification

1. Offerors shall identify the Biobased products to be purchased and used under this contract. For each Biobased product. the offeror shall specify the percentage of Biobased content, and for the USDA-designated Biobased content products, the offeror shall demonstrate that the products to be used under this contract will contain the percentage specified in the USDA recommendations or the highest level of Biobased material practicable, consistent with USDA's recommended percentages of Biobased content Product Description % Biobased Content

2. The offeror shall document prior experience in specifying, purchasing, using, and installing Biobased products. The offeror shall provide a list for all relevant contracts over the past two years involving the specification, purchase, and/or use of Biobased products. The offeror shall include a list of the Biobased products specified, purchased, used, and installed.

The following is a list of categories for biopreferred products that may be required in performance of this construction contract:

· 2-Cycle Engine Oils – 34% Minimum BioBased Content

· Adhesive and Mastic Removers – 58% Minimum BioBased Content

· Adhesives - 24% Minimum BioBased Content

· Bathroom and Spa Cleaners – 74% Minimum BioBased Content

· Bioremediation Materials – 86% Minimum BioBased Content

· Carpets – 7% Minimum BioBased Content

· Cleaning Tools – 22% Minimum BioBased Content

· Composite Panels – Acoustical – 37% Minimum BioBased Content

· Composite Panels – Countertops – 89% Minimum BioBased Content

· Composite Panels – Structural Wall Panels – 94% Minimum BioBased Content

· Concrete Curing Agents – 59% Minimum BioBased Content

· Concrete Repair Materials - Concrete Materials – 23% Minimum BioBased Content

· Concrete Repair Materials – Concrete Patching – 69% Minimum BioBased Content

· Concrete and Asphalt Cleaners – 70% Minimum BioBased Content

· Concrete and Asphalt Release Fluids – 87% Minimum BioBased Content

· Corrosion Preventatives – 53% Minimum BioBased Content

· Dust Suppressants – 85% Minimum BioBased Content

· Electronic Components Cleaners – 91% Minimum BioBased Content

· Epoxy Systems – 23% Minimum BioBased Content

· Erosion Control Materials – 77% Minimum BioBased Content

· Exterior Paints and Coatings – 83% Minimum BioBased Content

· Floor Cleaners and Protectors – 77% Minimum BioBased Content

· Floor Coverings (Non-Carpet) – 91% Minimum BioBased Content

· Gear Lubricants – 58% Minimum BioBased Content

· Glass Cleaners – 49% Minimum BioBased Content

· Greases – Multipurpose– 72% Minimum BioBased Content

· Hand Cleaners and Sanitizers – Hand Cleaners – 64% Minimum BioBased Content

· Hand Cleaners and Sanitizers – Hand Sanitizers – 73% Minimum BioBased Content

· Inks – Printer Toner (Greater Than 25 Pages Per Minute) – 20% Minimum BioBased Content

· Inks – Printer Toner (Less Than 25 Pages Per Minute) – 34% Minimum BioBased Content

· Interior Paints and Coatings – Latex and Waterborne Alkyd – 20% Minimum BioBased Content

· Intermediates - Paint and Coating Components – 22% Minimum BioBased Content

· Metal Cleaners and Corrosion Removers – Other Metal Cleaners – 56% Minimum BioBased Content

· Multipurpose Cleaners – 56% Minimum BioBased Content

· Multipurpose Lubricants – 88% Minimum BioBased Content

· Surface Guards, Molding, and Trim – 26% Minimum BioBased Content

· Wall Coverings – 62% Minimum BioBased Content

· Wood and Concrete Sealers – Membrane Concrete Sealers – 11% Minimum Biobased Content

· Wood and Concrete Sealers – Penetrating Liquids – 79% Minimum Biobased Content

· Wood and Concrete Stains – 39% Minimum BioBased Content

Other BioBased Products not stated above that may be used as identified by Contractor.

File details come from the government source that posted it. Updated .