About this file
This is a Minimum Qualifications Form for contractors responding to the ONIX Marketplace Challenge for the USSPACECOM Command and Control Facility Design-Build contract opportunity. Offerors must certify compliance with five core minimum qualifications to be eligible for consideration.
Financial and bonding capacity is the first requirement, mandating that offerors demonstrate the ability to provide a project payment and performance bond of at least $2.5 billion based on non-C4IT construction value. Bonds may be provided by multiple entities provided the combined total meets the threshold, and alternative security measures such as irrevocable letters of credit, parent company guarantees, or corporate balance sheet pledges are permissible if they reach the required security threshold in combination with surety bonds. Offerors must submit a letter from a Treasury-listed surety confirming bonding capacity. The second qualification requires verified CMMC Level 2 (Self) compliance per 32 C.F.R. 170.3 for the offeror and core team members to handle Controlled Unclassified Information. The third qualification stipulates that all on-site Construction Surveillance Technicians must possess active Top Secret and Sensitive Compartmented Information clearances prior to deployment. The fourth and fifth qualifications address experience requirements: mega project experience as a prime contractor in collaborative architecture and engineering design of complex projects valued at $1 billion or greater within the past ten years, and DOW C4IT mega project experience valued at $500 million or greater, including enterprise Tier 3/4 data centers and 24/7 Joint Operations Centers. Additional qualifications include experience with minimum 10-megawatt data centers and design-build experience with accredited ICD/ICS 705 SCIF/SAPF spaces exceeding 100,000 contiguous GSF and certified MIL-STD-188-1A HEMP-shielded structures with successful Pulsed Current Injection testing. Offerors must identify specific project names and page numbers from the Challenge Statement for each experience-based qualification and may submit supporting documentation as needed.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 1-USSPACECOM Project Table.docx | DOCX document | |
| USSPACECOM C2F DBC Challenge Statement.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1 ONIX Marketplace Challenge:
USSPACECOM Command and Control Facility: Design-Build Contractor Attachment 4: Offeror's Minimum Qualifications: Corporate Structure and Financial Capability
| Name of Offeror: |
| Instructions: |
� Note "Yes" or "No" under Response for each of the minimum qualifications noted below.
� With each line requesting minimum project experience, identify the project name and the page number on which the project is cited in the Challenge Statement.
� If additional documentation is requested, provide it with the response to the Challenge Statement.
By submitting this Minimum Qualifications Form, Offeror certifies that the below statements are true and correct.
| Minimum Qualification | Description | Response |
| Financial and Bonding Capacity | The Offeror has the capacity to provide a project payment and performance bond of a minimum of $2.5 billion (construction value of non-C4IT Work). Note, the bonds may be provided by multiple entities, provided the total overall bonding capacity is met. |
Offerors may submit alternative security in lieu of or supplementing bonds for consideration by AFCEC. Such alternative security must provide sufficient assurances that in combination with surety bonds reach the required security threshold such as Irrevocable Letters of Credit, Parent Company Guarantees, and Corporate Balance sheet pledges or escrow/holdback accounts. Offerors must attach a letter from a surety listed by the Treasury confirming the bonding capacity meets the criteria outlined above.
| Cybersecurity Maturity | Offeror and core Team Members possess verified CMMC Level 2 (Self) compliance per 32 C.F.R §170.3 to handle Controlled Unclassified Information (CUI) |
| Construction Surveillance Technicians (CST) | All on site CST will possess active TS and Sensitive Compartmented Information (SCI) clearances prior to deployment |
| Mega Project Experience | Offeror has demonstrated experience as a prime contractor in the collaborative architecture and engineering design of a complex mega project valued at $1 billion or greater within the last 10 years. |
| Identify Project Name and page number of Challenge Statement where discussed | |
| DOW C4IT Mega Project Experience | Offeror or subcontractor has past performance integrating and/or overseeing the design and construction of DOQ Command, Control Communications, Computers, and Information Technology (C4IT) infrastructure valued at $500 million or greater, including enterprise Tier 3/4 data centers and 24/7 Joint Operations Center. |
| Identify Project Name and page number of Challenge Statement where discussed | |
| Data Center | Offeror or a subcontractor has experience with a minimum 10 megawatt Data Center |
| Identify Project Name and page number of Challenge Statement where discussed | |
| ICD 705 & Hemp Design-Build Experience | Offeror or subcontractor has experience designing and constructing accredited ICD/ICS 705 SCIF/SAPF spaces greater than 100,000 continguous GSF and certified MIL-STD-188-1A HELP-shielded structures with successful Pulsed Current Injection testing. |