APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief ofEngineering)
SUBMITTED:
(Chief of Contracts Design)
SHEET NAME:PROJECT NUMBER:
CHECKED: DATE:
DRAWN:
OFFICE OF CIVIL
ENGINEERS
KEESLER AIR FORCE BASE
A. MARASCA G. REED
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
A R C H I T E C T S
1091 TOMMY MUNRO DR.
BILOXI, MS 39532
Telephone: 228.594.2323 www.egh.ms
STAMPENGINEERARCHITECT
100% SUBMITTAL
KEESLER AFB, BILOXI, MISSISSIPPI
PROJECT NUMBER: MAHG 11−1042
EGH PROJECT # 21−006
REPAIR BRYAN HALL B6901
CIVIL & STRUCTURAL
ENGINEER:
LIVE OAK ENGINEERING
MECHANICAL,
ELECTRICAL, &
TELECOMM ENGINEER:
DELL CONSULTING
KTC
KLK 02.18.2022
MAHG11-1042
MAHG111042 BRYAN HALL
RENOVATION
TITLE SHEET G008
02.18.2022
VOLUME 2 OF 2
ATTACHMENT 4
SOLICITATION FA301023R0001
1557824398E Text Box
1557824398E Text Box
1557824398E Text Box
1557824398E Text Box
REV A - 08/04/2022
Parking
Parking
Parking Parking
Parking
Parking
Parking
"L" ST.
"I" ST
GATE 7
GATE 8
GATE 2
GATE 3
GATE 9
GATE 1
IN
ST
RUM
EN
T
RU
NW
AY
Parking
"H" ST
Parking
M
EA
DO
W S
DR
IV
E
HANGAR ROAD
Gas Metering Station
R O D E N B E R G
A V E N U E
G A
LA
X Y
S
TR
E E T
Dia. #4
PLOESTI DRIVE
PHANTOM STREET
THUNDERBOLT STREET
EA
GL
E
ST
R
EE
T
ILS
Softball Dia. #5 Softball
Auto Wash Rack
OVE
R
RUN
FALCON STREET
B A
#5 Tank
Parking
Tr oo p Wa lk
HERC
ULES STREET
Review Stand
NW
-SE RUNWAY (DISUSED)
TA
XI
W
AY
Pa rk in g
TAXIWAY # 3
AIRCRAFT PARKING APRON #1
TAXIW
AY #
BAY RIDGE
CAPEHART
HOUSING
C
UR
TIS
D
RI
VE
A R N O
LD
Gas Reg. & Metering Sta.
CABELL STREET
SH
AD
YLA
WN
SHADOWLAWN
WHERRY HOUSING
M
IT
C
HE
LL
C
IR
CL
E
PINELAWN
POWER CIRCLE
GRASSLAWN
ORVILLE WRIGHT
Substation
PA
TR
IC
K
DR
IV
E
PATTON AVEHA
RM
ON
C
IR
C
LE
HA
RM
ON
C
IR
C
LE
FE
C
HE
T
DR
IV
E
FE
C
HE
T
DR
IV
E
VAN
DEN
BER
G
DRIVE
CHANNEL
CIRCLE
Measuring Set Temp. & Humidity
Tower
Parking
NE
-S
W R
UN
W
AY
0' X
TAXIWAY # 4
TA
XI
W
AY
AI
RC
RA
FT
P
AR
KI
NG
A
PR
ON #2
TAXIWAY # 5
AREA
STORAGE
AMMO
Fire
Area Training
PLAYGROUND
MARINA
PARK
S
IX
TH
S T
"D" ST
HOUSING
PINEHAVEN
"B" STREET
"C" STREET
"A" STREET
"M"
ST
MS Power Easement
"C" ST
Parking
Tennis Courts
Track Cinder
"Z " S
T "Z
" S T
"X S T
"E " S
T
Substation Power
"D" ST
Parking
S E C O N D
S T
FI
FT
H S
T
CHAPPIE JAMES AVE
Parking
Parking
"L" ST
Parking
Parking
1516 14
Parking
Rec Pad
P a rk in g
Rec Pad
Parking
03 0504
Monument
Parking
Parking
Parking
"C" Street Ditch
S
IX
TH
S
TR
E E T
"D" STREET
S COURT ST SOUTH
D E
VO
N
W
AY
"G" ST
MEADOWS DR
SERVICE DR
"H" ST
Parking
F
IR
S T S
TR
E E T
Parking
Parking
Water Tower
Parking
TA
XI
W
AY
AI
RC
RA
FT
P
AR
KI
NG
A
PR
ON #2
Parking Parking
FI
FT
H S
T
LA
R C H E R
B
LV
D
P a rk in g
Parking
Monument
TH
IR
D
S T
Parking
"E" STParking
Parking
BAYVIEW STREET
YORKSHIRE ROAD
B A U G H M A N
B
LV
D
Parking
Water Tank #6
Parking
B E N
AV
O N
R O
AD
M
IN
D
EN
R O
AD
K E N S
IN
G
TO
N
D R
IV
E CONCORD CIRCLE
Parking
Tennis Courts
S COURT ST NORTH
N COURT ST
Storage Boat
Tower Water
XX
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X
X
X
X
X
XX
X X
XX
X
XX
X
XX XX
X
X
X
X
X
X
X X X
X
X X
XX
X
X
X X
X X
XX
X
X X
XX
X
X
X
X
X
X X
X X
X
X
X
XX
XX
X X
X X
X
X
X
X
X X
X
X
X
X X
XX
XX
XX
XX
XX
X
XXXX
XXXX
XX
XXXX
XXXX
XX
XXXX
XXXX
XX
XX
X
XXX
"Z " S
T
XXX
XXXX
XXXX
XXX
XXXX
XXXX
XX
XXXX
X
XXXX
XX
XX
X
X
XXXX
XX
XXXX
XX
X
"E " S
T
Rec Pad
X
XX
Parking
Z E R O
S
TR
E E T
X X
XX
XX
XX
XXXX
XX XX
Z E R O
S
TR
E E T
XX
XX
XX
XX
XX
XXXX
XXXX
XX XX
XXXX
XX
XX XX
XXX
XX X
GULFPORT
BILOXI
KEESLER AIR FORCE BASE OCEAN
SPRINGS
BAY ST. LOUIS 20 MI.
NEW ORLEANS LA. 100 MI.
INTERSTATE 10
INTERSTATE 110
US ROUTE 90
MISSISSIPPI SOUND
BILOXI BACK BAY
PASS ROAD
PASCAGOULA 20 MI.
MOBILE AL. 50 MI.
US ROUTE 90
INTERSTATE 10
US
ROUTE
DESIGN TEAM
ARCHITECT
ELEY GUILD HARDY ARCHITECTS, PA
1091 TOMMY MUNRO DRIVE
BILOXI, MS 39532
228.594.2323
KYLE KISH, AIA, CDT, P.I.C.
EMAIL: kkish@egh.ms
DANIEL HAMBURG, AIA, LEED AP
EMAIL: dhamburg@egh.ms
JOSEPH CRAIN, AIA
EMAIL: jcrain@egh.ms
TAYLOR CLAUSSEN, AIA, NCIDQ
EMAIL: tclaussen@egh.ms
HEIDI SCHATTIN, AIA, LEED AP
EMAIL: hschattin@egh.ms
CIVIL ENGINEER
LIVE OAK ENGINEERING
955-B HOWARD AVENUE
BILOXI, MS 39530
228.207.0070
LLOYD "LES" SEYMOUR, P.E.
EMAIL: les@liveoakengineering.com
STRUCTURAL ENGINEER
LIVE OAK ENGINEERING
955-B HOWARD AVENUE
BILOXI, MS 39530
228.424.6455
CHARLES CHAPMAN, P.E.
EMAIL: charles@liveoakengineering.com
MECHANICAL ENGINEER
DELL CONSULTING
129 EAST GOVERNMENT STREET
PENSACOLA, FL32502
850.332.5687 x103
JASON MATIACIO, P.E., BCxP, BEMP, LEED AP BD+C EMAIL: Jason@DellConsultingLLC.com
ELECTRICAL ENGINEER
DELL CONSULTING
129 EAST GOVERNMENT STREET
PENSACOLA, FL32502
850.332.5687 x103
HAL DELL, P.E., RCDD, LEED AP BD+C
EMAIL: Hal@DellConsultingLLC.com
TELECOMMUNICATIONS
DELL CONSULTING
129 EAST GOVERNMENT STREET
PENSACOLA, FL32502
850.332.5687 x103
HAL DELL, P.E., RCDD, LEED AP BD+C
EMAIL: Hal@DellConsultingLLC.com
ABBREVIATIONS
& AND
@ AT
< ANGLE
A/C AIR CONDITIONING
ACT ACOUSTICAL CEILING TILE
ADDT'L ADDITIONAL
ADJ ADJUSTABLE
AF ACCESS FLOORING
AFD AUTOMATIC FIRE DAMPER
AFF ABOVE FINISH FLOORING
ALUM ALUMINUM
ALT ALTERNATE
ARCH ARCHITECT
BET BETWEEN
BIT BITUMEN
BJ BAR JOIST
BLDG BUILDING
BLK BLOCK
BLK'G BLOCKING
BLT BUILT
BM BEAM
BO BOTTOM OF
BOT BOTTOM
B.R. BACKER ROD
CAP CAPACITY
CB CATCH BASIN
C/C CENTER TO CENTER
CCTV CLOSED CIRCUIT ELEVATION
CFH CUBIC FEET/HOUR
CFM CUBIC FEET/MINUTE
CI. CAST IRON
C.J. CONTROL JOINT
CL CLEAR
CLG CEILING
CLO CLOSET
CLR COLOR
CMU CONCRETE MASONRY UNIT
CONTR. CONTRACTOR
COL COLUMN
COMP COMPRESSION/COMPRESSED
CONC CONCRETE
COND CONDENSATE
CONST CONSTRUCTION
CONT CONTINUOUS
CPLING COUPLING
CPT CARPET
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTR CENTERS
C CENTER LINE
C.W. COLD WATER
D/DIA DIAMETER
DB DRY BULB
DBL DOUBLE
DEFL DEFLECTION
DEPT. DEPARTMENT
DET/DTL DETAIL
DISP. DISPENSER
DK DARK
DN DOWN
D.P. DAWNPROOFING
DS DOWNSPOUT
DWG(S) DRAWING(S)
EA EACH
EDF ELECTRIC DRINKING FOUNTAIN
EF EXHAUST FAN
EFC EACH FACE
EJ EXPANSION JOINT
ELEC. ELECTRICAL
EL/ELEV ELEVATION
EMBED EMBEDDED
ENGR. ENGINEER
ENT ENTERING/ENTRY
EOP EXISTING OVERHEAD PRIMARY
EQ EQUAL
EQUIP. EQUIPMENT
ES EXPOSED STRUCTURE
ESP EXTERNAL STATIC PRESSURE
EXH EXHAUST
EXPAN EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FAC FIRE ALARM CABINET
FD FLOOR DRAIN
FAR FIRE ALARM REMOTE
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FINISH FLOOR ELEVATION
FH FIRE HYDRANT
FIN FINISH
FLR FLOOR
F.O.C. FACE OF CONCRETE
F.O.B. FACE OF BRICK
FR FRAME
FS FLOW SWITCH
FT FOOT/FEET
FTG FOOTING
GA GAUGE
GALV GALVANIZED
G.C. GENERAL CONTRACTOR
G.F. CMU GROUND FACE CMU
GL GLASS
GPM GALLONS PER MINUTE
GYP.BD GYPSUM BOARD
HB HOSE BIBB
HC HANDICAP
HD/WR HARDWARE
HM HOLLOW METAL
HDN. HAND
HP HIGH POINT
HORIZ. HORIZONTAL
HR HOUR
HT HEIGHT
H.W. HOT WATER
HVAC. HEATING, VENTILATION,
AIR CONDITIONING
IC INTERCOM
INSUL INSULATION
INT INTERIOR
INV INVERT
JAN JANITOR
JT JOINT
JST JOIST
L LENGTH, LONG
LAM LAMINATED(D)
L.A.T. LAY-IN ACOUSTICAL CEILING
LAV LAVATORY
LF LINEAR FEET
LG LEG
LP LIGHT POLE
MA MIXED AIR
MAS. MASONRY
MAT'L MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR/MFGR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
M.O. MANSONRY OPENING
MOD. MODIFIED
MRV MOISTURE RELEASE VENT
M.T. METAL THRESHOLD
MTD MOUNTED
MTL METAL
N/A NOT APPLICABLE
NF NATURAL FINISH
NIC NOT IN CONTRACT
NO./# NUMBER
NOM NOMINAL
NR NARROW RIB
NS NOT SHOWN
NTS NOT TO SCALE
OA OUTSIDE AIR
O.C. ON CENTER
OCEW ON CENTER EACH WAY
OH OVERHEAD
OPN'G OPENING
OPP. OPPOSITE
OZ. OUNCE
+/-.± PLUS OR MINUS
P/PT PAINT
PART'N PARTITION
PDI WATER HAMMER ARRESTOR
PF PREFINISH(ED)
PL PLATE
?? PROPERTY LINE
PLAS. PLASTIC LAMINATE
PLYWD. PLYWOOD
PNL PANEL
PP POWER POLE
PR PAIR
PREFAB PREFABRICATED
PROJ PROJECTION
PSF POUNDS/SQUARE FOOT
PSI POUNDS/SQUARE INCH
P.T.D. PAPER TOWEL DISPENSER
PVC POLYVINYL CHLORIDE
QT QUARRY TILE
QTB QUARRY TILE BASE
QTY QUANTITY
R/RAD RADIUS
RA RETURN AIR
RB RUBBER BASE
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCED
REQ'D REQUIRED
RET RETURN
RM ROOM
RPM REVOLUTIONS PER MINUTE
RTU ROOF-TOP UNIT
SA SUPPLY AIR
SAN SANITARY
SCWD SOLID CORE WOOD
SD SPLITTER DAMPER
SECT SECTION
SF STOREFRONT/SQUARE FEET
SHT SHEET
SIM SIMILAR
SL SLOPE
SP SPACING
SPEC SPECIFIED/SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STRUCT. STRUCTURAL
SUP SUPPLY
SUSP SUSPENDED
SYN SYNTHETIC
T&B TOP AND BOTTOM
TBM TEMPORARY BENCH MARK
TEL TELEPHONE
T&G TOUNGE AND GROOVE
TH/THK THICK
THRESH. THRESHOLD
TLT TOILET
T.O. TOP OF
T.O.B. TOP OF BEAM
TOS TOP OF STRUCTURE
TP TOILET PAPER HOLDER
TRTD TREATED
TYP TYPICAL ALL SIMILAR
CONDITIONS
U.C. UNDER COUNTER
U.L. UNDERWRITER'S LABORATORY
UNO UNLESS NOTED OTHERWISE
VAR VARIES
VD VOLUME DAMPER
VERT VERTICAL
V.C.T. VINYL COMPOSITION TILE
VTR VENT-THRU-ROOF
V.W.C. VINYL WALL COVERING
W. WIDE, WIDTH
W/ WITH
WCO WALL CLEANOUT
WD WOOD
WG WATER GAUGE
WGVP WATER GAUGE VISION PANEL
WH WATER HEATER
WP WATERPROOFING
WV WATER VAUVE
WMF WELDED WIRE FABRIC
DRAWING INDEX
GRAPHIC LEGEND
WOOD BLOCKING
CONT BATT INSULATION /
ACOUSTICAL BATTS
FLOOR DRAIN
ROOM DESIGNATION
DOOR OPENING
WINDOW TYPE
COLUMN GRID LINE
DETAIL
ELEVATION
BUILDING SECTION / DETAIL
100A
ROOM NAME
A300
XX
A
6.2
WALL PARTITION TYPE
A200
A520
DOO3 PHOTO DESIGNATION
LOCATION
X
X
XX
X
X DEMO KEYNOTES
RENOVATION KEYNOTES
MATERIAL LEGEND
EARTH
CONCRETE IN
SECTION/PLAN
WOOD DOOR
METAL IN SECTION
GRASS
FINISH WOOD
ROUGH WOOD
CONSTRUCTION
IN SECTION
RIGID INSULATION
CAST STONE
PROJECT MAP
BASE CONTRACTING
BLDG 4605
VECTRUS
BLDG 4705
MAIN GATE / VISITORS CENTER
(WHITE AVE VIA HWY 90)
SECURITY
POLICE
BLDG 3524
CONTRACTOR'S
TRUCK ROUTE
BLDG 6901
NOTE: CONTRACTOR TO
FINALIZE LAYDOWN AREAS
AND TRUCK ROUTES AFTER
AWARD. INFORMATION GIVEN
IS FOR PRICING ONLY.
VICINITY MAP
1. ALL DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO QUANTIFY THE
MATERIALS SPECIFIED AND INDICATE THEIR INTENDED RELATIONSHIP TO EACH
OTHER. THE DRAWINGS ARE NOT TO BE SCALED. THE VARIOUS SCALES USED ON
THE DRAWINGS MAY NOT ALLOW FOR ALL THE FITTINGS, OFFSETS, AND
ACCESSORIES THAT MAY BE REQUIRED TO COMPLETE THE WORK. THE
CONTRACTOR SHALL CAREFULLY INVESTIGATE THE CONDITIONS THAT WOULD
AFFECT THE WORK TO BE PERFORMED AND SHALL ARRANGE SUCH WORK AS
NECESSARY TO COMPLY WITH THE INTENT OF THE CONSTRUCTION CONDITIONS.
2. THIS PROJECT CONTAINS ASBESTOS MATERIAL IN THE CONSTRUCTION AREA-
SEE ASBESTOS REPORT FOR MORE INFORMATION.
3. THIS PROJECT CONTAINS LEAD BASE PAINT MATERIAL IN THE CONSTRUCTION
AREA- SEE LEAD BASED PAINT REPORT FOR MORE INFORMATION.
GENERAL NOTES
APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief ofEngineering)
SUBMITTED:
(Chief of Contracts Design)
SHEET NAME:PROJECT NUMBER:
CHECKED: DATE:
DRAWN:
OFFICE OF CIVIL
ENGINEERS
KEESLER AIR FORCE BASE
A. MARASCA G. REED
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
A R C H I T E C T S
1091 TOMMY MUNRO DR.
BILOXI, MS 39532
Telephone: 228.594.2323 www.egh.ms
STAMPENGINEERARCHITECT
CIVIL & STRUCTURAL
ENGINEER:
LIVE OAK ENGINEERING
MECHANICAL,
ELECTRICAL, &
TELECOMM ENGINEER:
DELL CONSULTING
KTC
KLK 02.18.2022
MAHG11-1042
MAHG111042 BRYAN HALL
RENOVATION
DRAWING INDEX &
PROJECT INFORMATION G009
VOLUME 1 VOLUME 2
INDEX - GENERAL (VOL 1)
G000 TITLE SHEET
G001 DRAWING INDEX & PROJECT INFORMATION
G002 PHASING PLAN
G003 EXISTING CONDITIONS - TOPO PAGE 1
G004 EXISTING CONDITIONS - TOPO PAGE 2
G005 EXISTING CONDITIONS - TOPO PAGE 3
G006 EXISTING CONDITIONS - TOPO PAGE 4
G007 STRUCTURE TABLE
INDEX - LIFE SAFETY
LS100 CODE INFORMATION
LS101 1ST FLOOR LIFE SAFETY PLAN
LS102 2ND FLOOR LIFE SAFETY PLAN
INDEX - CIVIL
C100 DEMOLITION PLAN
C200 CIVIL SITE PLAN
C201 DETAIL SHEET
C400 SITE UTILITY PLAN
C500 SITE DETAILS
INDEX - STRUCTURAL
S000 GENERAL NOTES
S001 GENERAL NOTES CONT.
S101 FIRST FLOOR REFERENCE PLAN
S102 2ND FLOOR REFERENCE PLAN
S103 ROOF REFERENCE PLAN
S104 ENLARGED REFERENCE PLANS
S105 ENLARGED REFERENCE PLANS
S201 TYPICAL DETAILS
S202 TYPICAL DETAILS
S203 TYPICAL DETAILS FOR SLAB ENCLOSURE & OPENINGS
S204 TYPICAL DETAILS FOR SLAB ENCLOSURE & OPENINGS
S301 SECTIONS
S401 ENLARGED SECTIONS
INDEX - DEMOLITION
AD001 DEMO SITE PLAN
AD002 HAZARDOUS MATERIALS PLAN
AD100 DEMO CRAWL SPACE PLAN
AD101 DEMO 1ST FLOOR - OVERALL
AD102 DEMO 2ND FLOOR - OVERALL
AD103 DEMO 1ST FLOOR - PART A
AD104 DEMO 1ST FLOOR - PART B
AD105 DEMO 1ST FLOOR - PART C
AD106 DEMO 1ST FLOOR - PART D
AD107 DEMO 2ND FLOOR - PART A
AD108 DEMO 2ND FLOOR - PART B
AD109 DEMO 2ND FLOOR - PART C
AD110 DEMO 2ND FLOOR - PART D
AD111 INTERIOR DEMOLITION PHOTOS
AD112 EXTERIOR DEMOLITION PHOTOGRAPHS
AD130 DEMO ROOF PLAN
AD131 EXISTING ROOF PHOTOS
AD132 ROOF DEMO DETAILS
AD133 CANOPY DEMO DETAILS
AD200 DEMO ELEVATIONS
INDEX - ARCHITECTURAL
A001 NEW SITE PLAN
A002 SITE DETAILS
A100 CRAWL SPACE PLAN
A101 FIRST FLOOR - OVERALL
A102 2ND FLOOR - OVERALL
A103 1ST FLOOR - PART A
A104 1ST FLOOR - PART B
A105 1ST FLOOR - PART C
A106 1ST FLOOR - PART D
A107 2ND FLOOR - PART A
A108 2ND FLOOR - PART B
A109 2ND FLOOR - PART C
A110 2ND FLOOR - PART D
A120 RCP - 1ST FLOOR - OVERALL
A121 RCP - 2ND FLOOR - OVERALL
A122 1ST FLOOR RCP - PART A
A123 1ST FLOOR RCP - PART B
A124 1ST FLOOR RCP - PART C
A125 1ST FLOOR RCP - PART D
A126 2ND FLOOR RCP - PART A
A127 2ND FLOOR RCP - PART B
A128 2ND FLOOR RCP - PART C
A129 2ND FLOOR RCP - PART D
A130 ROOF PLAN
A200 ELEVATIONS
A400 ENLARGED FLOOR PLANS
A401 PLAN DETAILS
A402 NEW ROOF DETAILS
A403 CANOPY DETAILS
A410 ENLARGED STAIR PLANS
A411 ENLARGED STAIR PLANS
A412 ENLARGED STAIR SECTIONS
A600 PARTITION TYPES
A601 CRAWL SPACE & 1ST FLOOR OPENING
SCHEDULE
A602 2ND FLOOR OPENING SCHEDULE
A603 FRAME TYPES/ HJS DETAILS
A604 HJS DETAILS
INDEX - INTERIORS
I100 FIRST FLOOR - FINISH PLAN - OVERALL
I101 SECOND FLOOR - FINISH PLAN - OVERALL
I102 FIRST FLOOR - FURNITURE PLAN - OVERALL
I103 SECOND FLOOR - FURNITURE PLAN - OVERALL
I104 FIRST FLOOR - SIGNAGE PLAN - OVERALL
I105 SECOND FLOOR - SIGNAGE PLAN - OVERALL
I400 ENLARGED FINISH FLOOR PLANS
I401 ENLARGED FINISH FLOOR PLANS
I402 ENLARGED MILLWORK PLANS & ELEVATIONS
I403 MILLWORK DETAILS & INTERIOR RENDERINGS
I404 ENLARGED MILLWORK PLANS & ELEVATIONS
I405 ENLARGED MILLWORK PLANS & ELEVATIONS
I406 INTERIOR ELEVATIONS
I410 ENLARGED FURNITURE PLANS
I600 1ST FLOOR FINISH SCHEDULE & KEY
I601 2ND FLOOR FINISH SCHEDULE
INDEX - GENERAL (VOL 2)
G008 TITLE SHEET
G009 DRAWING INDEX & PROJECT INFORMATION
INDEX - FIRE PROTECTION
FP001 LEGENDS, NOTES & ABBREVIATIONS
FP111 1ST FLOOR OVERALL PLAN - FIRE PROTECTION
FP112 2ND FLOOR OVERALL PLAN - FIRE PROTECTION
INDEX - MECHANICAL
M001 LEGENDS, NOTES & ABBREVIATIONS
M100 SITE PLAN - MECHANICAL
MD100 CRAWLSPACE OVERALL PLAN - DEMOLITION
MD101 1ST FLOOR OVERALL PLAN - DEMOLITION
MD102 2ND FLOOR OVERALL PLAN - DEMOLITION
MD103 1ST FLOOR PART A PLAN - DEMOLITION
MD104 1ST FLOOR PART B PLAN - DEMOLITION
MD105 1ST FLOOR PART C PLAN - DEMOLITION
MD106 1ST FLOOR PART D PLAN - DEMOLITION
MD107 2ND FLOOR PART A PLAN - DEMOLITION
MD108 2ND FLOOR PART B PLAN - DEMOLITION
MD109 2ND FLOOR PART C PLAN - DEMOLITION
MD110 2ND FLOOR PART D PLAN - DEMOLITION
MD130 ROOF PLAN - DEMOLITION
M603 SCHEDULES
M604 SCHEDULES
M605 SCHEDULES
M606 CHILLED WATER PIPING DIAGRAM
M607 HEATING HOT WATER PIPING DIAGRAM
M701 CONTROLS
M702 CONTROLS
M703 CONTROLS
M704 CONTROLS
M705 CONTROLS
M706 CONTROLS
M707 CONTROLS
M110 CRAWLSPACE PLAN
M111 1ST FLOOR OVERALL PLAN - DUCTWORK
M112 2ND FLOOR OVERALL PLAN - DUCTWORK
M113 1ST FLOOR PART A PLAN - DUCTWORK
M114 1ST FLOOR PART B PLAN - DUCTWORK
M115 1ST FLOOR PART C PLAN - DUCTWORK
M116 1ST FLOOR PART D PLAN - DUCTWORK
M117 2ND FLOOR PART A PLAN - DUCTWORK
M118 2ND FLOOR PART B PLAN - DUCTWORK
M119 2ND FLOOR PART C PLAN - DUCTWORK
M120 2ND FLOOR PART D PLAN - DUCTWORK
M131 1ST FLOOR OVERALL PLAN - PIPING
M132 2ND FLOOR OVERALL PLAN - PIPING
M161 ROOF PLAN
M401 ENLARGED PLANS & ELEVATIONS
M402 ENLARGED PLANS & ELEVATIONS
M403 ENLARGED PLANS & ELEVATIONS
M404 ENLARGED PLANS & ELEVATIONS
M405 ENLARGED PLANS & ELEVATIONS
M406 ENLARGED PLANS & ELEVATIONS
M407 ENLARGED PLANS & ELEVATIONS
M408 ENLARGED PLANS & ELEVATIONS
M409 ENLARGED PLANS & ELEVATIONS
M410 ENLARGED PLANS & ELEVATIONS
M411 ENLARGED PLANS & ELEVATIONS
M412 ENLARGED PLANS & ELEVATIONS
M413 ENLARGED PLANS & ELEVATIONS
M501 DETAILS
M502 DETAILS
M601 SCHEDULES
M602 SCHEDULES
INDEX - PLUMBING
P001 LEGENDS, NOTES & ABBREVIATIONS
PD100 CRAWLSPACE OVERALL PLAN - DEMOLITION
PD101 1ST FLOOR OVERALL PLAN - DEMOLITION
PD102 2ND FLOOR OVERALL PLAN - DEMOLITION
PD130 ROOF PLAN - DEMOLITION
PD401 1ST FLOOR ENLARGED PLANS - DEMOLITION
PD402 1ST FLOOR PART C PLAN - DEMOLITION
P111 1ST FLOOR OVERALL PLAN - WASTE & VENT
P112 2ND FLOOR OVERALL PLAN - WASTE & VENT
P130 CRAWLSPACE OVERALL PLAN - DOMESTIC
WATER
P131 1ST FLOOR OVERALL PLAN - DOMESTIC WATER
P132 2ND FLOOR OVERALL PLAN - DOMESTIC WATER
P161 ROOF PLAN - STORM & VENT
P401 1ST FLOOR REST ROOM ENLARGED PLANS -
WASTE & VENT
P402 2ND FLOOR REST ROOM ENLARGED PLANS -
WASTE & VENT
P403 1ST FLOOR REST ROOM ENLARGED PLANS -
DOMESTIC WATER
P404 2ND FLOOR REST ROOM ENLARGED PLANS -
DOMESTIC WATER
P405 1ST FLOOR MECHANICAL ENLARGED PLANS
P406 2ND FLOOR MECHANICAL ENLARGED PLANS
P501 DETAILS
P502 DETAILS
P503 DETAILS
P601 SCHEDULES
P901 WASTE & VENT RISER DIAGRAMS
P902 WASTE & VENT RISER DIAGRAMS
P903 WASTE & VENT RISER DIAGRAMS
P904 DOMESTIC WATER RISER DIAGRAMS
P905 DOMESTIC WATER RISER DIAGRAMS
P906 DOMESTIC WATER RISER DIAGRAMS
INDEX - ELECTRICAL
E001 LEGEND AND NOTES
E002 ABBREVIATIONS
E100 SITE PLAN- ELECTRICAL
ED100 CRAWLSPACE FLOOR PLAN - DEMOLITION
ED101 1ST FLOOR OVERALL PLAN - DEMOLITION
ED102 2ND FLOOR OVERALL PLAN - DEMOLITION
ED103 ROOF OVERALL PLAN - DEMOLITION
ED130 ROOF PLAN - DEMOLITION
E708 SCHEDULES
E709 SCHEDULES
E710 SCHEDULES
E711 SCHEDULES
E712 SCHEDULES
E713 SCHEDULES
E714 SCHEDULES
E715 SCHEDULES
E716 SCHEDULES
E717 SCHEDULES
E718 SCHEDULES
E719 SCHEDULES
E720 -- NOT USED --
E721 -- NOT USED --
E110 CRAWLSPACE FLOOR PLAN - LIGHTING
E111 1ST FLOOR OVERALL PLAN - LIGHTING
E112 2ND FLOOR OVERALL PLAN - LIGHTING
E113 1ST FLOOR PART A PLAN - LIGHTING
E114 1ST FLOOR PART B PLAN - LIGHTING
E115 1ST FLOOR PART C PLAN - LIGHTING
E116 1ST FLOOR PART D PLAN - LIGHTING
E117 2ND FLOOR PART A PLAN - LIGHTING
E118 2ND FLOOR PART B PLAN - LIGHTING
E119 2ND FLOOR PART C PLAN - LIGHTING
E120 2ND FLOOR PART D PLAN - LIGHTING
E131 1ST FLOOR OVERALL PLAN - POWER
E132 2ND FLOOR OVERALL PLAN - POWER
E133 1ST FLOOR PART A PLAN - POWER
E134 1ST FLOOR PART B PLAN - POWER
E135 1ST FLOOR PART C PLAN - POWER
E136 1ST FLOOR PART D PLAN - POWER
E137 2ND FLOOR PART A PLAN - POWER
E138 2ND FLOOR PART B PLAN - POWER
E139 2ND FLOOR PART C PLAN - POWER
E140 2ND FLOOR PART D PLAN - POWER
E143 1ST FLOOR PART A PLAN - MECHANICAL POWER
E144 1ST FLOOR PART B PLAN - MECHANICAL POWER
E145 1ST FLOOR PART C PLAN - MECHANICAL POWER
E146 1ST FLOOR PART C PLAN - MECHANICAL POWER
E147 2ND FLOOR PART A PLAN - MECHANICAL POWER
E148 2ND FLOOR PART B PLAN - MECHANICAL POWER
E149 2ND FLOOR PART C PLAN - MECHANICAL POWER
E150 2ND FLOOR PART D PLAN - MECHANICAL POWER
E161 ROOF PLAN - MECHANICAL POWER
E171 1ST FLOOR OVERALL PLAN - FIRE ALARM
E172 2ND FLOOR OVERALL PLAN - FIRE ALARM
E173 1ST FLOOR PART A PLAN - FIRE ALARM
E174 1ST FLOOR PART B PLAN - FIRE ALARM
E175 1ST FLOOR PART C PLAN - FIRE ALARM
E176 1ST FLOOR PART D PLAN - FIRE ALARM
E177 2ND FLOOR PART A PLAN - FIRE ALARM
E178 2ND FLOOR PART B PLAN - FIRE ALARM
E179 2ND FLOOR PART C PLAN - FIRE ALARM
E180 2ND FLOOR PART D PLAN - FIRE ALARM
E190 ROOF PLAN - LIGHTNING PROTECTION
E501 DETAILS
E502 DETAILS
E503 DETAILS
E504 DETAILS
E505 DETAILS
E506 DETAILS
E507 DETAILS
E601 SINGLE LINE DIAGRAM
E602 SINGLE LINE DIAGRAM
E701 SCHEDULES
E702 SCHEDULES
E703 SCHEDULES
E704 SCHEDULES
E705 SCHEDULES
E706 SCHEDULES
E707 SCHEDULES
INDEX - TELECOM
T001 LEGEND, NOTES & ABBREVIATIONS
T100 SITE PLAN - TELECOMMUNICATIONS
T110 CRAWLSPACE FLOOR PLAN -
TELECOMMUNICATIONS
T111 1ST FLOOR OVERALL FLOOR PLAN -
TELECOMMUNICATIONS
T112 2ND FLOOR OVERALL FLOOR PLAN -
TELECOMMUNICATIONS
T113 1ST FLOOR PART A FLOOR PLAN -
TELECOMMUNICATIONS
T114 1ST FLOOR PART B FLOOR PLAN -
TELECOMMUNICATIONS
T115 1ST FLOOR PART C FLOOR PLAN -
TELECOMMUNICATIONS
T116 1ST FLOOR PART D FLOOR PLAN -
TELECOMMUNICATIONS
T117 2ND FLOOR PART A FLOOR PLAN -
TELECOMMUNICATIONS
T118 2ND FLOOR PART B FLOOR PLAN -
TELECOMMUNICATIONS
T119 2ND FLOOR PART C FLOOR PLAN -
TELECOMMUNICATIONS
T120 2ND FLOOR PART D FLOOR PLAN -
TELECOMMUNICATIONS
T401 ENLARGED PLANS - TELECOMMUNICATIONS
T402 ENLARGED PLANS - TELECOMMUNICATIONS
T403 ENLARGED PLANS - TELECOMMUNICATIONS
T404 ENLARGED PLANS - TELECOMMUNICATIONS
T501 DETAILS
T502 DETAILS
T503 DETAILS
T504 DETAILS
T505 DETAILS
T601 RISER DIAGRAMS
T602 RISER DIAGRAMS
T603 RISER DIAGRAMS
T604 RISER DIAGRAMS
T605 RISER DIAGRAMS
FIRE PROTECTION LEGEND
ACT ACOUSTIC CEILING TILE
AHJ AUTHORITY HAVING JURISDICTION
BFP BACKFLOW PREVENTER
BOD BASIS OF DESIGN
FDC FIRE DEPARTMENT CONNECTION
FPS FEET PER SECOND
GAL GALLONS
GPM GALLONS PER MINUTE
IAW IN ACCORDANCE WITH
IBC INTERNATIONAL BUILDING CODE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NICET NATIONAL INSTITUTE FOR CERTIFICATION IN
ENGINEERING TECHNOLOGIES
PIV POST INDICATOR VALVE
PSI POUNDS PER SQUARE INCH
SF SQUARE FEET
FIRE PROTECTION ABBREVIATIONS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ALL FIRE PROTECTION AND SPRINKLER WORK SHALL BE PERFORMED
BY A LICENSED FIRE SPRINKLER CONTRACTOR IN THE STATE OF
MISSISSIPPI. ALL WORK SHALL BE IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS, APPLICABLE CODES AND
STANDARDS, AND NFPA 13. RE-CERTIFY SYSTEM AS REQUIRED BY
NFPA 13.
SYSTEM SHALL BE DESIGNED BY A NICET LEVEL III (OR HIGHER)
SPRINKLER SYSTEM TECHNICIAN WHO IS IN THE FULL TIME
EMPLOYMENT OF THE INSTALLING CONTRACTOR. SHOP/DESIGN
DRAWINGS AND HYDRAULIC CALCULATIONS SHALL BE REVIEWED BY A
PROFESSIONAL ENGINEER LICENSED IN MISSISSIPPI WITH AT LEAST
FIVE (5) YEARS DOCUMENTED FIRE PROTECTION EXPERIENCE.
FIRE PROTECTION WORK CONSISTS OF THE ADDITION OF A NEW WET
PIPE SPRINKLER SYSTEM TO AN EXISTING TWO-STORY BUILDING. NO
SPRINKLER SYSTEM CURRENTLY EXISTS.
CONTRACTOR SHALL OBTAIN A RECENT FIRE FLOW TEST PRIOR TO
BID. IN THE EVENT THAT A RECENT (WITHIN 6 MONTHS OF BID DATE)
FLOW TEST IS NOT AVAILABLE, THE CONTRACTOR SHALL CONDUCT
OR WITNESS A FLOW TEST PRIOR TO BID.
MAXIMUM WATER FLOW VELOCITY AS CALCULATED IN HYDRAULIC
CALCULATIONS SHALL NOT EXCEED 16 FPS.
CONTRACTOR SHALL VISIT THE SITE TO DETERMINE CONNECTION
POINTS AND PIPE ROUTING FOR THE REQUIRED SPRINKLER SYSTEM
INSTALLATION PRIOR TO BID.
COORDINATE HEAD LOCATIONS WITH REFLECTED CEILING PLANS AND
WORK OF OTHER TRADES.
PROVIDE FIRE STOPPING FOR ALL PIPING PENETRATING RATED
FLOORS, WALLS, PARTY WALLS AND CEILINGS. FIRE STOPPING
METHODS SHALL BE PER CODE REQUIREMENTS.
SPRINKLER HEADS LOCATED IN ACOUSTIC CEILING TILES SHALL BE IN
THE CENTER OF TILE.
ALL AREAS ARE LIGHT HAZARD UNLESS OTHERWISE NOTED
FIRE PROTECTION GENERAL NOTES
NAME OF FACILITY: BRYAN HALL
LOCATION: KEESLER AFB, MS
TYPE OF CONSTRUCTION: NON-COMBUSTIBLE
OWNER: KEESLER AFB FIRE MARSHAL
AUTHORITY HAVING JURISDICTION: KEESLER AFB, MS
GENERAL BUILDING HAZARD: LIGHT HAZARD
FIRE PROTECTION DESIGN CRITERIA
FLOW TEST DATE: JULY 12, 2021
FLOW TEST CONDUCTED BY: KEESLER AFB UTILITIES AUTHORITY
SOURCE OF WATER SUPPLY: MUNICIPAL, GRAVITY
STATIC PRESSURE: 68 PSIG
RESIDUAL PRESSURE: 55 PSIG
FLOW: 1278 GPM
PRELIMINARY FIRE FLOW TEST DATA
LIGHT HAZARD - WET SYSTEM
REMOTE AREA: 3000 SF
MAXIMUM AREA PER SPRINKLER: 225 SF
MINIMUM WATER FLOW DENSITY: 0.1 GPM/SF
PRELIMINARY SPRINKLER DEMAND: 390 GPM
HOSE STREAM: 250 GPM
ORDINARY HAZARD GROUP I - WET SYSTEM
REMOTE AREA: 3000 SF
MAXIMUM AREA PER SPRINKLER: 130 SF
MINIMUM WATER FLOW DENSITY: 0.15 GPM/SF
PRELIMINARY SPRINKLER DEMAND: 585 GPM
HOSE STREAM: 500 GPM
ORDINARY HAZARD GROUP II - WET SYSTEM
REMOTE AREA: 375 SF
MAXIMUM AREA PER SPRINKLER: 130 SF
MINIMUM WATER FLOW DENSITY: 0.2 GPM/SF
PRELIMINARY SPRINKLER DEMAND: 100 GPM
PRELIMINARY HYDRAULIC ANALYSIS
NEW PIPING
PIPE UP
PIPE DOWN
MEP Engineering
129 E. Government Street Pensacola, FL 32502
P: 850-332-5687 F:850-332-6629
APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief ofEngineering)
SUBMITTED:
(Chief of Contracts Design)
SHEET NAME:PROJECT NUMBER:
CHECKED: DATE:
DRAWN:
OFFICE OF CIVIL
ENGINEERS
KEESLER AIR FORCE BASE
A. MARASCA G. REED
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
A R C H I T E C T S
1091 TOMMY MUNRO DR.
BILOXI, MS 39532
Telephone: 228.594.2323 www.egh.ms
STAMPENGINEERARCHITECT
Mississippi Certificate Number E-1969
Dell Consulting project:21-072 Jason A. Matiacio 30457
IGL
JAM 02.18.2022
MAHG11-1042
MAHG111042 BRYAN HALL
RENOVATION
LEGENDS, NOTES &
ABBREVIATIONS FP001
R. R.
A
B
C
D
E
F
G
H
I
J
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
MECH
A126
MECH
D101
BOILER ROOM
D100
STAIR
D105
STAIR
B109
COMM
B115
COMM
A115
STOR
B127
COMM
C109
FILING
A104
INSTRUCT 5
(PIPELINE)
A100
INSTRUCT 4
(PIPELINE)
A101
INSTRUCT 3
(PIPELINE)
A102COPY
A103
INSTRUCT 2
(PIPELINE)
A105
INSTRUCT 1
(PIPELINE)
A106
FILING
B105
TLT
A107
CMNDR
A120
FILING
A116
SUPER TASK
A112
FILING
B116
STOR
B119
FILING
B120 CHIEF
B122
OFFICE
B126
OFFICE
B130
OFFICE
B131
OFFICE
B125
FILING
C110
INSTRUCT
(ADVANCED)
A109
SUPER WAITING
A110
INSTRUCT
(SUPERVISORS)
A111
HALL
A113
ELEC
A114
BLDG CONF
A117
SENIOR NCO
A119
WAITING
A118
MEN
B110
WOMEN
B111
INSTRUCT 6
(PIPELINE)
B108
INSTRUCT 7
(PIPELINE)
B107
INSTRUCT 8
(PIPELINE)
B106 COPY
B104
INSTRUCT 9
(PIPELINE)
B103
INSTRUCT 10
(PIPELINE)
B102
TLT
B101
BREAK ROOM
B112
ELEC
B114
HALL
B113
PERSONNEL
B118 WAITING AREA
B117
ADMIN
B121
TRASH
B123
CLASSROOM 1
A124
CLASSROOM 2
A123
JAN
A122
RESERVE WAITING
B128
STOR
B129 LIASON WAITING
B124
SERVER ROOM
D104
CLASSROOM 3
C103
CLASSROOM 4
C102
JAN
C101
CORRIDOR
1-2
CORRIDOR
1-6
CLASSROOM 7
C112
STOR
C111
ELEC
C108
HALL
C107
CLASSROOM 6
C106
CLASSROOM 5
C105
STUDENT BREAK
ROOM
(ADVANCED)
D115
STUDENT BREAK
ROOM (PIPELINE)
C113
STOR
C114CLASSROOM 9
C115
CLASSROOM 8
C116
MECH
C117
CORRIDOR
1-4
COMM/NODE
A125
MECH
C104
MECH
D112
CORRIDOR
1-5
CORRIDOR
1-7
MECH
B100
VENDING
B134
CORRIDOR
1-1
MECH
A108
WOMEN
A121
CORRIDOR
1-3
MEN
C100
COMM
D109
FILING
D110
LAB 1
B133
LAB 2
B132
LAB 3
D103
LAB 4
D102
SHELTER
STORAGE
D111
HALL
D107
ELEC
D108LAB 5
D106
LAB 7
D113
LAB 6
D114
PROVIDE COMPLETE FIRE SPRINKLER
COVERAGE IAW NFPA-13, NFPA-20, UFC
3-600-01, THE SPECIFICATIONS, AND AHJ.
1 2
1 1
4" FIRE LINE TO REMOTE FDC. COORDINATE
WITH CIVIL FOR CONTINUATION.
6" FIRE LINE TO SITE BFP. COORDINATE
WITH CIVIL FOR CONTINUATION.
LOBBY
1-0
6" FIRE LINE UP TO B200 MECHANICAL.
FP111
1ST FLOOR
30'-0"
2ND FLOOR
44'-0"
CRAWL SPACE
23'-10"
A
1ST FLOOR
30' - 0"
2ND FLOOR
44' - 0"
CRAWL SPACE
23' - 10"
4"-FIRE LINE TO
REMOTE FDC
6"-FIRE LINE TO
SITE BFP
MEP Engineering
129 E. Government Street Pensacola, FL 32502
P: 850-332-5687 F:850-332-6629
APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief ofEngineering)
SUBMITTED:
(Chief of Contracts Design)
SHEET NAME:PROJECT NUMBER:
CHECKED: DATE:
DRAWN:
OFFICE OF CIVIL
ENGINEERS
KEESLER AIR FORCE BASE
A. MARASCA G. REED
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
A R C H I T E C T S
1091 TOMMY MUNRO DR.
BILOXI, MS 39532
Telephone: 228.594.2323 www.egh.ms
STAMPENGINEERARCHITECT
Mississippi Certificate Number E-1969
Dell Consulting project:21-072 Jason A. Matiacio 30457
IGL
JAM 02.18.2022
MAHG11-1042
MAHG111042 BRYAN HALL
RENOVATION
1ST FLOOR OVERALL
PLAN - FIRE
PROTECTION
FP111
1/16" = 1'-0"FP111FP111
1 1ST FLOOR OVERALL PLAN - FIRE PROTECTION
SHEET NOTES
1 ORDINARY HAZARD GROUP I.
2 ORDINARY HAZARD GROUP II.
3 PROVIDE ALL PIPING WITHIN 5'-0" OF THE BUILDING FOOTPRINT. COORDINATE
WITH CIVIL FOR DEPTH OF COVER AND CONNECTION TO UNDERGROUND SITE
PIPING.
4 PROVIDE FLOOR CONTROL VALVE ASSEMBLY AND DRAIN RISER TO SERVE EACH
FLOOR LEVEL. PROVIDE TAMPER SWITCH AND FLOW SWITCH AND COORDINATE
WITH FIRE ALARM.
N
1/8" = 1'-0"FP111FP111
2 FIRE RISER SECTION
R.
A
B
C
D
E
F
G
H
I
J
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
STAIR
D204
JAN
D205
STAIR
B204
JAN
B205
FILING
A209
COMM
A208
FILING
D210
FILING
C210
COMM
C209
STOR
A212
STOR
B217
VENDING
B221
OFFICE
B219
MECH
D200
MECH
B200
MULTIPURPOSE
B203
CLASSROOM 12
A200
CLASSROOM 11
A201
CLASSROOM 10
A202
MECH
A203
STOR/TRASH
B214
CLASSROOM 15
A211
STOR
A210ELEC
A207
HALL
A206
CLASSROOM 14
A205
CLASSROOM 13
A204
MECH
B215
DRILL
B216CLASSROOM
B218
CUBE FARM
B220
CLASSROOM 17
A215
CLASSROOM 16
A216
MECH
A217
MECH
C204 CLASSROOM 18
C203
CLASSROOM 19
C202
CONFERENCE
ROOM
D203
LAB 12
D202 LAB 13
D201
CLASSROOM 27
D211
LAB 14
D206
CLASSROOM 22
C213
STOR
C211
ELEC
C208
HALL
C207
CLASSROOM 21
C206
CLASSROOM 20
C205
MECH
C218 CLASSROOM 23
C217
CLASSROOM 24
C216
CLASSROOM 25
C215
CLASSROOM 26
D215
LAB 15
D214
LAB 16
D213
MECH
D212
LACTATION
B222
CORRIDOR
2-2
CORRIDOR
2-6
CORRIDOR
2-4
JAN
A214
JAN
C201
STOR
B208
CORRIDOR
2-1
CORRIDOR
2-5
STOR
C214
CORRIDOR
2-7
CORRIDOR
2-3
WOMEN
A213
MEN
C200
MEN
B206
WOMEN
B207
FILING
B212
COMM
B211
COMM
D209
ELEC
D208
LAB 10
B201
LAB 9
B202
LAB 11
B213
HALL
B209
ELEC
B210
HALL
D207
PROVIDE COMPLETE FIRE SPRINKLER
COVERAGE IAW NFPA-13, NFPA-20, UFC
3-600-01, THE SPECIFICATIONS, AND AHJ.
1 1 1
1 1
STORAGE
B202.1
6" FIRE LINE DOWN TO B100 MECHANICAL.
FP111
MEP Engineering
129 E. Government Street Pensacola, FL 32502
P: 850-332-5687 F:850-332-6629
APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief ofEngineering)
SUBMITTED:
(Chief of Contracts Design)
SHEET NAME:PROJECT NUMBER:
CHECKED: DATE:
DRAWN:
OFFICE OF CIVIL
ENGINEERS
KEESLER AIR FORCE BASE
A. MARASCA G. REED
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
A R C H I T E C T S
1091 TOMMY MUNRO DR.
BILOXI, MS 39532
Telephone: 228.594.2323 www.egh.ms
STAMPENGINEERARCHITECT
Mississippi Certificate Number E-1969
Dell Consulting project:21-072 Jason A. Matiacio 30457
IGL
JAM 02.18.2022
MAHG11-1042
MAHG111042 BRYAN HALL
RENOVATION
2ND FLOOR OVERALL
PLAN - FIRE
PROTECTION
FP112
1/16" = 1'-0"FP111FP112
1 2ND FLOOR OVERALL PLAN - FIRE PROTECTION
SHEET NOTES
1 ORDINARY HAZARD GROUP I.
2 PROVIDE FLOOR CONTROL VALVE ASSEMBLY AND DRAIN RISER TO SERVE EACH
FLOOR LEVEL. PROVIDE TAMPER SWITCH AND FLOW SWITCH AND COORDINATE
WITH FIRE ALARM.
N
M
M
HVAC LEGEND
SUPPLY AIR DUCT UP
SUPPLY AIR DUCT DOWN
RETURN AIR DUCT UP
RETURN AIR DUCT DOWN
EXHAUST AIR DUCT UP
EXHAUST AIR DUCT DOWN
WxH
RECTANGULAR DUCTWORK, SIZES SHOWN ARE INTERNAL
CLEAR DIMENSIONS; FIRST FIGURE IS SIDE SHOWN
ø ø ø
ROUND GALVANIZED STEEL DUCTWORK;
SIZE SHOWN IS SHEET METAL DIAMETER
ROUND BRANCH DUCT TAKEOFF WITH SPIN-IN COLLAR
AND MANUAL VOLUME DAMPER
W xH
WxH RECTANGULAR BRANCH DUCT TAKE OFF WITH 45°
COLLAR AND MANUAL VOLUME DAMPER
EXISTING DUCTWORK
DEMO DUCTWORK
FACTORY FABRICATED/INSULATED FLEXIBLE ROUND DUCT
SQUARE THROAT ELBOW IN RECTANGULAR DUCT
WITH TURNING VANES
LONG RADIUS ELBOW (R = 1.5 x DIAMETER)
RECTANGULAR TO ROUND DUCT TRANSITION
RECTANGULAR TO RECTANGULAR DUCT TRANSITION
AUTOMATIC DAMPER (OPPOSED)
AUTOMATIC DAMPER (PARALLEL)
MANUAL VOLUME DAMPER
FD
FIRE DAMPER
SMOKE DAMPER
SD
FIRE/SMOKE DAMPER
FSD
CEILING DIFFUSER. PROVIDE SURFACE MOUNT STYLE WITH
TRIM RING FOR GYPSUM BOARD CEILING AND LAY-IN TYPE AT T-
BAR CEILING GRID. ROUND NECK SIZE AND AIRFLOW AS
INDICATED. BACK FACE OF DIFFUSER SHALL HAVE INSULATION
BLANKET. "24" = FACE SIZE; "08" = NECK DIAMETER
4-WAY THROW OR AS SHOWN ON PLANS
T THERMOSTAT
CONNECT TO EXISTING
PIPE DOWN
PIPE UP
RETURN AIR GRILLE. PROVIDE SURFACE MOUNT STYLE WITH
TRIM RING FOR GYPSUM BOARD CEILING AND LAY-IN TYPE AT T-
BAR CEILING GRID. PROVIDE REGISTERS WITH FACE-OPERATED
OPPOSED BLADE DAMPER. SIZE, AIRFLOW, DUCT COLLAR AS
INDICATED.
EXHAUST AIR GRILLE. PROVIDE SURFACE MOUNT STYLE WITH
TRIM RING FOR GYPSUM BOARD CEILING AND LAY-IN TYPE AT T-
BAR CEILING GRID. PROVIDE REGISTERS WITH FACE-OPERATED
OPPOSED BLADE DAMPER. SIZE, AIRFLOW, DUCT COLLAR AS
INDICATED.
DEMO PIPING
EXISTING PIPING
NEW PIPING
PIPE CAP
BALL VALVE
BUTTERFLY VALVE
CHECK VALVE
BALANCING VALVE
GATE VALVE
INLINE STRAINER VALVE
INLINE STRAINER WITH BLOWDOWN
VALVE AND HOSE BIBB
TWO WAY CONTROL VALVE
AUTOMATIC AIR VENT
PRESSURE REDUCING VALVE
RELIEF VALVE
GAUGE AND COCK
GAUGE TEST PORT (PETE'S PLUG)
THERMOMETER
THERMOWELL
UNION; DIELECTRIC CONNECTION
EQUIPMENT TAG
AHU
FLEXIBLE DUCT CONNECTION
NEW DUCTWORK
0 CD8
200 CFM
10ø
2424x24RG
400 CFM
10ø
2424x24EG
400 CFM
HVAC ABBREVIATIONS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
INSTALL ALL MECHANICAL EQUIPMENT IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS, CONTRACT
DOCUMENTS, AND APPLICABLE CODES AND STANDARDS.
CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. PROVIDE ALL FITTINGS, ACCESSORIES, PIPING, DUCTWORK, AND CONTROLS AS REQUIRED
FOR A FULLY FUNCTIONAL SYSTEM TO MEET THE DESIGN INTENT.
THE APPROXIMATE LOCATIONS OF EXISTING UTILITIES ARE SHOWN. THE CONTRACTOR SHALL DETERMINE THE EXACT
LOCATION AND SIZE OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK.
COORDINATE EQUIPMENT CLEARANCES (AS RECOMMENDED BY MANUFACTURER) WITH ALL DISCIPLINES BEFORE
INSTALLATION.
CONCRETE HOUSEKEEPING PADS FOR MECHANICAL EQUIPMENT SHALL BE MINIMUM 4-INCH THICKNESS. PAD SHALL EXTEND
BEYOND THE EQUIPMENT A MINIMUM OF 6 IN. ON ALL SIDES WITH CHAMFERED EDGES.
VERIFY CLEARANCE SPACE AVAILABLE, OFFSETS REQUIRED, STRUCTURAL OPENINGS, AND WORK BY OTHER TRADES PRIOR TO FABRICATION OF DUCTWORK AND PIPING. SUBMIT SHOP DRAWINGS ON DUCTWORK AND PIPING LAYOUT. COORDINATE
WITH STRUCTURE. PRESSURE TEST ALL DUCTWORK AND PIPING FOR LEAKS.
PROVIDE ACCESS PANELS FOR INSTALLATION IN WALLS AND CEILINGS, WHERE REQUIRED, TO SERVICE DAMPERS, VALVES, SMOKE DETECTORS, AND OTHER CONCEALED MECHANICAL EQUIPMENT.
PROVIDE ACCESS DOORS IN DUCTWORK TO PROVIDE ACCESS FOR ALL SMOKE DETECTORS, FIRE DAMPERS, VOLUME DAMPERS, COILS, AND OTHER ITEMS LOCATED IN THE DUCTWORK THAT REQUIRE SERVICE AND/OR INSPECTION.
ALL EQUIPMENT, PIPING, DUCTWORK, ETC. SHALL BE SUPPORTED AS DETAILED, SPECIFIED, AND REQUIRED TO PROVIDE A VIBRATION-FREE INSTALLATION. PROVIDE DUCT AND PIPE FLEX CONNECTIONS FOR ALL EQUIPMENT CONNECTIONS. PROVIDE VIBRATION ISOLATORS FOR ALL EQUIPMENT; SEE SPECIFICATIONS AND DETAILS. PROVIDE SEISMIC BRACING AS REQUIRED.
LOCATIONS AND SIZES OF FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED WITH ALL OTHER TRADES INVOLVED.
ALL EQUIPMENT REQUIRING CONDENSATE DRAIN LINES SHALL BE PIPED FULL SIZE OF THE UNIT DRAIN OUTLET TO THE NEAREST DISPOSAL POINT AS INDICATED. PROVIDE A TRAP ON ALL DRAIN OUTLETS AND SLOPE PIPING MINIMUM 1/8 IN. PER
FOOT.
PROVIDE AUTOMATIC AIR VENTS AT HIGH POINTS AND DRAIN VALVES AT LOW POINTS ON ALL PIPING.
PIPE INSULATION AND VAPOR BARRIERS SHALL BE CONTINUOUS THROUGH PIPE HANGERS.
ALL DUCTWORK DIMENSIONS, AS SHOWN ON THE DRAWINGS, ARE INTERNAL CLEAR DIMENSIONS.
COORDINATE DIFFUSER, REGISTER, AND GRILLE LOCATIONS WITH REFLECTED CEILING PLANS, LIGHTING, AND OTHER CEILING
MOUNTED DEVICES.
EXTERIOR LOUVERS ARE INDICATED FOR INFORMATION ONLY. LOUVER DIMENSIONS INDICATED DO NOT INCLUDE FRAME OR
FLANGES.
NO DUCTWORK OR PIPING SHALL RUN PARALLEL WITH AND OVER WALLS. AVOID ROUTING DUCTWORK AND PIPING OVER LIGHTS WHEREVER POSSIBLE. MAINTAIN MINIMUM 6” CLEARANCE BETWEEN HVAC INSULATION TO TOP OF LIGHTS. PROVIDE MANUFACTURER'S RECOMMENDED CLEARANCE AROUND MECHANICAL EQUIPMENT FOR PROPER OPERATION AND ROUTINE
MAINTENANCE.
SEAL ALL DUCT PENETRATIONS OF WALLS AIRTIGHT, REGARDLESS OF WHETHER WALLS ARE FIRE-RATED OR NOT. PROVIDE
SLEEVES AND SEAL ALL PIPE PENETRATIONS OF WALLS AIRTIGHT.
ALL OPENINGS IN FIRE WALLS DUE TO DUCTWORK, PIPING, CONDUIT, ETC. SHALL BE FIRE-STOPPED WITH AN APPROVED UL-
LISTED PRODUCT.
ALL AIR INTAKE OPENINGS TO EXTERIOR SHALL HAVE A MIN 10'-0” CLEARANCE FROM ANY EXHAUST OPENING TO PREVENT
RECIRCULATION.
MOUNT DUCTWORK AS HIGH AS POSSIBLE WHERE EXPOSED, UNLESS OTHERWISE NOTED.
THERMOSTATS INDICATED ADJACENT TO DOORWAYS SHALL BE LOCATED WITHIN 18" OF JAMB AND MOUNTED AT A HEIGHT
CONSISTENT WITH LIGHT SWITCHES.
ALL EXPOSED CONTROL WIRING (MECHANICAL AND ELECTRICAL ROOMS) SHALL BE IN CONDUIT. ALL REMAINING CONTROL
WIRING SHALL BE PLENUM-RATED CABLE.
COORDINATE CONTROLS WORK WITH EXISTING BUILDING AUTOMATION SYSTEM PROVIDER (JOHNSON CONTROLS). PROVIDE CONSISTENCY WITH EXISTING POINT NAMING, DYNAMIC GRAPHICS, SCHEDULING, AND ALARMS.
EXISTING CONDITIONS ARE BASED ON PREVIOUS AS-BUILT DRAWINGS AND FIELD INVESTIGATIONS, THEREFORE EXISTING
DUCTWORK, PIPING, AND EQUIPMENT SHOWN MAY NOT REFLECT ACTUAL INSTALLATION.
HVAC GENERAL NOTES
GPM GALLONS PER MINUTE
GV GRAVITY VENTILATOR
HD HEAD
HP HORSEPOWER
HR HOUR
HW HEATING HOT WATER
HWP HEATING HOT WATER PUMP
HWR HEATING HOT WATER RETURN
HWS HEATING HOT WATER SUPPLY
HZ HERTZ
IAW IN ACCORDANCE WITH
IN. INCH
KW KILOWATT
LAT LEAVING AIR TEMPERATURE
LB POUNDS
LWT LEAVING WATER TEMPERATURE
MAT MIXED AIR TEMPERATURE
MAX MAXIMUM
MBH THOUSANDS OF BTUH
MCA MINIMUM CIRCUIT AMPACITY
MFR MANUFACTURER
MIN MINIMUM
MOCP MAXIMUM OVERCURRENT PROTECTION
N/A NOT APPLICABLE
NC NORMALLY CLOSED
NO NORMALLY OPEN; NUMBER
NTS NOT TO SCALE
OA OUTDOOR AIR
OAL OUTDOOR AIR LOUVER
P PUMP
PD PRESSURE DROP
PH PHASE
PHC PREHEAT COIL
PSI POUNDS PER SQUARE INCH
QTY QUANTITY
R RADIUS; RELAY
RA RETURN AIR
RAT RETURN AIR TEMPERATURE
RG RETURN AIR GRILLE
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RPM REVOLUTIONS PER MINUTE
RR RETURN AIR REGISTER
SA SUPPLY AIR
SAT SUPPLY AIR TEMPERATURE
SF SQUARE FEET; SUPPLY FAN
SP STATIC PRESSURE
SR SUPPLY AIR REGISTER; SIDEWALL REGISTER
SS STAINLESS STEEL
TG TRANSFER GRILLE
TSP TOTAL STATIC PRESSURE
TYP TYPICAL
UC DOOR UNDERCUT
UH UNIT HEATER
V VOLTS
VAV VARIABLE AIR VOLUME
VFD VARIABLE FREQUENCY DRIVE
W WATTS
WB WET BULB
WC WATER COLUMN
WG WATER GAUGE
WPD WATER PRESSURE DROP
Φ DIAMETER
A AMPS
AAV AUTOMATIC AIR VENT
ACH AIR CHANGE PER HOUR
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
AP ACCESS PANEL
APD AIR PRESSURE DROP
AHRI AIR CONDITIONING, HEATING, AND
REFRIGERATION INSTITUTE
AS AIR SEPARATOR
B BOILER
BHP BRAKE HORSEPOWER
BTU BRITISH THERMAL UNIT
BTUH BTU PER HOUR
C CONDENSATE
CC COOLING COIL
CD CEILING DIFFUSER
CDWP CONDENSER WATER PUMP
CFM CUBIC FEET PER MINUTE
CH CHILLER
CHW CHILLED WATER
CHWP CHILLED WATER PUMP
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CO CLEANOUT
DB DRY BULB
DDC DIRECT DIGITAL CONTROLS
DEG DEGREE
DELTA-T TEMPERATURE DIFFERENCE
DEMO DEMOLISH
DG DOOR GRILLE
DN DOWN
DP DIFFERENTIAL PRESSURE
EA EACH
EAL EXHAUST AIR LOUVER
EAT ENTERING AIR TEMPERATURE
ECM ELECTRONICALLY COMMUTATED MOTOR
EF EXHAUST FAN
EFF EFFICIENCY
EG EXHAUST AIR GRILLE
ELEC ELECTRICAL
ER EXHAUST AIR REGISTER
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
EWT ENTERING WATER TEMPERATURE
EX. EXISTING
EXH EXHAUST AIR
F/A FIRE ALARM
°F DEGREE FAHRENHEIT
FCU FAN COIL UNIT
FD FIRE DAMPER; FLOOR DRAIN
FLA FULL LOAD AMPS
FLR FLOOR
FMS FLOW MEASURING STATION
FO FLAT OVAL
FPI FINS PER INCH
FPM FEET PER MINUTE
FRG FILTER RETURN GRILLE
FS FLOAT SWITCH; FLOW SWITCH
FSD FIRE AND SMOKE DAMPER
FT FEET
GA GAUGE
GAL GALLONS
THREE WAY CONTROL VALVE
FILTER RETURN AIR GRILLE. PROVIDE SURFACE MOUNT STYLE
WITH TRIM RING FOR GYPSUM BOARD CEILING AND LAY-IN TYPE
AT T-BAR CEILING GRID. ACCOMMODATE 2" MERV 8 FILTER.
24x24FRG
400 CFM
10⌀
W/H FO
FLAT OVAL DUCTWORK, SIZES SHOWN ARE INTERNAL CLEAR
DIMENSIONS; FIRST FIGURE IS SIDE SHOWN
MEP Engineering
129 E. Government Street Pensacola, FL 32502
P: 850-332-5687 F:850-332-6629
APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief ofEngineering)
SUBMITTED:
(Chief of Contracts Design)
SHEET NAME:PROJECT NUMBER:
CHECKED: DATE:
DRAWN:
OFFICE OF CIVIL
ENGINEERS
KEESLER AIR FORCE BASE
A. MARASCA G. REED
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
A R C H I T E C T S
1091 TOMMY MUNRO DR.
BILOXI, MS 39532
Telephone: 228.594.2323 www.egh.ms
STAMPENGINEERARCHITECT
Mississippi Certificate Number E-1969
Dell Consulting project:21-072 Jason A. Matiacio 30457
BGA
JAM 02.18.2022
MAHG11-1042
MAHG111042 BRYAN HALL
RENOVATION
LEGENDS, NOTES &
ABBREVIATIONS M001
D
EX. COOLING TOWER TO REMAIN
BLDG 6901
REMOVE EX. HVAC
SYSTEMS SERVING
GENERATOR BUILDING
IN THEIR ENITRETY.
MEP Engineering
129 E. Government Street Pensacola, FL 32502
P: 850-332-5687 F:850-332-6629
APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief ofEngineering)
SUBMITTED:
(Chief of Contracts Design)
SHEET NAME:PROJECT NUMBER:
CHECKED: DATE:
DRAWN:
OFFICE OF CIVIL
ENGINEERS
KEESLER AIR FORCE BASE
A. MARASCA G. REED
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
A R C H I T E C T S
1091 TOMMY MUNRO DR.
BILOXI, MS 39532
Telephone: 228.594.2323 www.egh.ms
STAMPENGINEERARCHITECT
Mississippi Certificate Number E-1969
Dell Consulting project:21-072 Jason A. Matiacio 30457
BGA
JAM 02.18.2022
MAHG11-1042
MAHG111042 BRYAN HALL
RENOVATION
SITE PLAN -
MECHANICAL M1001/32" = 1'-0"M405M100
1 SITE PLAN - MECHANICAL
N
J
I
H
G
F
E
D
C
B
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
REMOVE EX. CHWS&R AND
HWS&R PIPING BACK TO MECH
ROOM WALL PENETRATION. EX.
PIPING INSIDE MECH ROOM
SHALL REMAIN.
REMOVE EX. CHWS&R AND
HWS&R PIPING UP TO MECH
ROOMS ABOVE. PREPARE EX.
FLOOR PENETRATIONS FOR
INSTALLATION OF NEW PIPING.
REMOVE EX. CHWS&R AND
HWS&R PIPING UP TO MECH
ROOMS ABOVE. PREPARE EX.
FLOOR PENETRATIONS FOR
INSTALLATION OF NEW PIPING.
REMOVE EX. CHWS&R AND
HWS&R PIPING UP TO MECH
ROOMS ABOVE. PREPARE EX.
FLOOR PENETRATIONS FOR
INSTALLATION OF NEW PIPING.
REMOVE EX. CHWS&R AND
HWS&R PIPING UP TO MECH
ROOMS ABOVE. PREPARE EX.
FLOOR PENETRATIONS FOR
INSTALLATION OF NEW PIPING.
REMOVE EX. CHWS&R AND
HWS&R PIPING UP TO MECH
ROOMS ABOVE. PREPARE EX.
FLOOR PENETRATIONS FOR
INSTALLATION OF NEW PIPING.
A B
C D
MEP Engineering
129 E. Government Street Pensacola, FL 32502
P: 850-332-5687 F:850-332-6629
APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief ofEngineering)
SUBMITTED:
(Chief of Contracts Design)
SHEET NAME:PROJECT NUMBER:
CHECKED: DATE:
DRAWN:
OFFICE OF CIVIL
ENGINEERS
KEESLER AIR FORCE BASE
A. MARASCA G. REED
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
A R C H I T E C T S
1091 TOMMY MUNRO DR.
BILOXI, MS 39532
Telephone: 228.594.2323 www.egh.ms
STAMPENGINEERARCHITECT
Mississippi Certificate Number E-1969
Dell Consulting project:21-072 Jason A. Matiacio 30457
BGA
JAM 02.18.2022
MAHG11-1042
MAHG111042 BRYAN HALL
RENOVATION
CRAWLSPACE OVERALL
PLAN - DEMOLITION MD100
1/16" = 1'-0"MD100
1 CRAWLSPACE OVERALL PLAN - DEMOLITION
1.
2.
MECHANICAL DEMOLITION SCOPE CONSISTS OF REMOVING ALL EXISTING HVAC
SYSTEMS IN THEIR ENTIRETY INCLUDING ALL DUCTWORK, PIPING, SUPPORTS, AIR
TERMINAL UNITS, DIFFUSERS/GRILLES/REGISTERS, LOUVERS, AND CONTROLS,
UNLESS NOTED OTHERWISE.
PATCH AND SEAL UNUSED WALL AND/OR FLOOR OPENINGS TO MATCH EXISTING,
COORDINATE WITH STRUCTURAL.
GENERAL NOTES
N
N
NOT TO SCALE
KEY PLAN
G
F
E
D
C
B
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
EX. CHILLER AND ASSOCIATED PIPING TO
REMAIN
EX. CONDENSER WATER PUMP AND
ASSOCIATED PIPING TO REMAIN
EX. PRIMARY CHILLED WATER PUMP AND
ASSOCIATED PIPING TO REMAIN
EX. AHU-9A EX. AHU-12
EX. AHU-7
EX. AHU-8
EX. AHU-10
EX. BOILER, PRIMARY HEATING HOT
WATER PUMP, AND PRIMARY LOOP
PIPING TO REMAIN
EX. VFD
EX. VFD
EX. VFD
EX. VFD
A B
C D
MEP Engineering
129 E. Government Street Pensacola, FL 32502
P: 850-332-5687 F:850-332-6629
APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief ofEngineering)
SUBMITTED:
(Chief of Contracts Design)
SHEET NAME:PROJECT NUMBER:
CHECKED: DATE:
DRAWN:
OFFICE OF CIVIL
ENGINEERS
KEESLER AIR FORCE BASE
A. MARASCA G. REED
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
A R C H I T E C T S
1091 TOMMY MUNRO DR.
BILOXI, MS 39532
Telephone: 228.594.2323 www.egh.ms
STAMPENGINEERARCHITECT
Mississippi Certificate Number E-1969
Dell Consulting project:21-072 Jason A. Matiacio 30457
BGA
JAM 02.18.2022
MAHG11-1042
MAHG111042 BRYAN HALL
RENOVATION
1ST FLOOR OVERALL
PLAN - DEMOLITION MD101
1/16" = 1'-0"M405MD101
1 1ST FLOOR OVERALL PLAN - DEMOLITION
1.
2.
MECHANICAL DEMOLITION SCOPE CONSISTS OF REMOVING ALL EXISTING HVAC
SYSTEMS IN THEIR ENTIRETY INCLUDING ALL DUCTWORK, PIPING, SUPPORTS, AIR
TERMINAL UNITS, DIFFUSERS/GRILLES/REGISTERS, LOUVERS, AND CONTROLS,
UNLESS NOTED OTHERWISE.
PATCH AND SEAL UNUSED WALL AND/OR FLOOR OPENINGS TO MATCH EXISTING,
COORDINATE WITH STRUCTURAL.
GENERAL NOTES
N
N
NOT TO SCALE
KEY PLAN
H
G
F
E
D
C
B
A
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
EX. AHU-6EX. AHU-3
EX. AHU-5EX. AHU-2
EX. AHU-4EX. AHU-1
EX. AHU-11
EX. ERV-1
EX. SECONDARY
HEATING HOT
WATER PUMP
EX. SECONDARY
CHILLED WATER
PUMP
EX. VFD
EX. EAL
EX. OAL
A B
C D
MEP Engineering
129 E. Government Street Pensacola, FL 32502
P: 850-332-5687 F:850-332-6629
APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief ofEngineering)
SUBMITTED:
(Chief of Contracts Design)
SHEET NAME:PROJECT NUMBER:
CHECKED: DATE:
DRAWN:
OFFICE OF CIVIL
ENGINEERS
KEESLER AIR FORCE BASE
A. MARASCA G. REED
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
A R C H I T E C T S
1091 TOMMY MUNRO DR.
BILOXI, MS 39532
Telephone: 228.594.2323 www.egh.ms
STAMPENGINEERARCHITECT
Mississippi Certificate Number E-1969
Dell Consulting project:21-072 Jason A. Matiacio 30457
BGA
JAM 02.18.2022
MAHG11-1042
MAHG111042 BRYAN HALL
RENOVATION
2ND FLOOR OVERALL
PLAN - DEMOLITION MD102
1/16" = 1'-0"MD102
1 2ND FLOOR OVERALL PLAN - DEMOLITION
N
N
NOT TO SCALE
KEY PLAN
1.
2.
MECHANICAL DEMOLITION SCOPE CONSISTS OF REMOVING ALL EXISTING HVAC
SYSTEMS IN THEIR ENTIRETY INCLUDING ALL DUCTWORK, PIPING, SUPPORTS, AIR
TERMINAL UNITS, DIFFUSERS/GRILLES/REGISTERS, LOUVERS, AND CONTROLS,
UNLESS NOTED OTHERWISE.
PATCH AND SEAL UNUSED WALL AND/OR FLOOR OPENINGS TO MATCH EXISTING,
COORDINATE WITH STRUCTURAL.
GENERAL NOTES
F
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
EX. AHU-8
EX. AHU-7
EX. CHWS&R AND
HWS&R PIPING DN TO
CRAWLSPACE AND UP
TO SECOND FLOOR
EX. CHWS&R AND
HWS&R PIPING DN TO
CRAWLSPACE AND UP
TO SECOND FLOOR
EX. VFD
1 / MD105
/ M
D
1 / MD105
/ M
D
1 / MD106
/ M
D
/ M
D
1 / MD104
A B
C D
MEP Engineering
129 E. Government Street Pensacola, FL 32502
P: 850-332-5687 F:850-332-6629
APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief ofEngineering)
SUBMITTED:
(Chief of Contracts Design)
SHEET NAME:PROJECT NUMBER:
CHECKED: DATE:
DRAWN:
OFFICE OF CIVIL
ENGINEERS
KEESLER AIR FORCE BASE
A. MARASCA G. REED
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
A R C H I T E C T S
1091 TOMMY MUNRO DR.
BILOXI, MS 39532
Telephone: 228.594.2323 www.egh.ms
STAMPENGINEERARCHITECT
Mississippi Certificate Number E-1969
Dell Consulting project:21-072 Jason A. Matiacio 30457
BGA
JAM 02.18.2022
MAHG11-1042
MAHG111042 BRYAN HALL
RENOVATION
1ST FLOOR PART A PLAN
- DEMOLITION MD103
1/8" = 1'-0"M405MD103
1 1ST FLOOR PART A PLAN - DEMOLITION
N
N
NOT TO SCALE
KEY PLAN
# SHEET NOTES
1 REMOVE EXISTING HVAC SYSTEM IN ITS ENTIRETY INCLUDING DUCTWORK, PIPING,
SUPPORTS, AIR TERMINAL UNITS, AND DIFFUSERS/GRILLES/REGISTERS. REMOVE
CHILLED WATER AND HEATING HOT WATER BRANCH PIPING AND ACCESSORIES.
2 PROVIDE A TWO-TON PORTABLE AIR CONDITIONING UNIT TO CONTINUOUSLY
SERVE THE SPACE DURING CONSTRUCTION. PORTABLE UNIT SHALL BE REMOVED
ONCE CONSTRUCTION IS COMPLETE AND FCU-1.5 IS OPERATIONAL AND FULLY
UNDER CONTROL.
3 EXISTING AIR HANDLING UNIT SHALL BE TURNED OVER TO THE BASE IN GOOD
CONDITION. CAREFULLY DISCONNECT AND REMOVE AIR HANDLING UNIT FOR
FUTURE REUSE. CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING
OFFICER PRIOR TO DEMOLITION AND MOVE THE AIR HANDLING UNIT TO A
LOCATION ON BASE AS SPECIFIED BY THE CONTRACTING OFFICER.
4 COORDINATE WITH THE BASE CONTRACTING OFFICER AND JOHNSON CONTROLS
PRIOR TO REMOVAL OF ANY HVAC DIRECT DIGITAL CONTROL DEVICES AND
EQUIPMENT. THE FOLLOWING CONTROLS SHALL BE TURNED OVER TO THE BASE
IN GOOD CONDITION FOR FUTURE REUSE: ALL VMA FIELD CONTOLLERS, ALL FEC
FIELD CONTROLLERS, (1x) NAE, (1x) NCE, ALL ZONE DDC THERMOSTATS, AND ALL
DAMPER ACTUATORS.
D
C
B
A
14 15 16 17 18 19 20 21 22 23 24 25 26 27
EX. AHU-10
/ M
D
1 / MD105
/ M
D
1 / MD106
EX. VFD
EX. CHWS&R AND HWS&R
PIPING DN TO CRAWLSPACE
AND UP TO SECOND FLOOR
/ M
D
1 / MD106
1 / MD103
/ M
D
A B
C D
MEP Engineering
129 E. Government Street Pensacola, FL 32502
P: 850-332-5687 F:850-332-6629
APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief ofEngineering)
SUBMITTED:
(Chief of Contracts Design)
SHEET NAME:PROJECT NUMBER:
CHECKED: DATE:
DRAWN:
OFFICE OF CIVIL
ENGINEERS
KEESLER AIR FORCE BASE
A. MARASCA G. REED
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
A R C H I T E C T S
1091 TOMMY MUNRO DR.
BILOXI, MS 39532
Telephone: 228.594.2323 www.egh.ms
STAMPENGINEERARCHITECT
Mississippi Certificate Number E-1969
Dell Consulting project:21-072 Jason A. Matiacio 30457
BGA
JAM 02.18.2022
MAHG11-1042
MAHG111042 BRYAN HALL
RENOVATION
1ST FLOOR PART B PLAN
- DEMOLITION MD104
1/8" = 1'-0"M405MD104
1 1ST FLOOR PART B PLAN - DEMOLITION
N
N
NOT TO SCALE
KEY PLAN
# SHEET NOTES
1 REMOVE EXISTING HVAC SYSTEM IN ITS ENTIRETY INCLUDING DUCTWORK, PIPING,
SUPPORTS, AIR TERMINAL UNITS, AND DIFFUSERS/GRILLES/REGISTERS. REMOVE
CHILLED WATER AND HEATING HOT WATER BRANCH PIPING AND ACCESSORIES.
2 COORDINATE WITH THE BASE CONTRACTING OFFICER AND JOHNSON CONTROLS
PRIOR TO REMOVAL OF ANY HVAC DIRECT DIGITAL CONTROL DEVICES AND
EQUIPMENT. THE FOLLOWING CONTROLS SHALL BE TURNED OVER TO THE BASE
IN GOOD CONDITION FOR FUTURE REUSE: ALL VMA FIELD CONTOLLERS, ALL FEC
FIELD CONTROLLERS, (1x) NAE, (1x) NCE, ALL ZONE DDC THERMOSTATS, AND ALL
H
G
F
2 3 4 5 6 7 8 9 10 11 12 13 14
EX. AHU-9A
EX. CHWS&R AND HWS&R
PIPING DN TO CRAWLSPACE
AND UP TO SECOND FLOOR
/ M
D
1 / MD106
1 / MD103
/ M
D
/ M D
1 / MD104
/ M
D
1 / MD103
1 1
A B
C D
MEP Engineering
129 E. Government Street Pensacola, FL 32502
P: 850-332-5687 F:850-332-6629
APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief ofEngineering)
SUBMITTED:
(Chief of Contracts Design)
SHEET NAME:PROJECT NUMBER:
CHECKED: DATE:
DRAWN:
OFFICE OF CIVIL
ENGINEERS
KEESLER AIR FORCE BASE
A. MARASCA G. REED
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
A R C H I T E C T S
1091 TOMMY MUNRO DR.
BILOXI, MS 39532
Telephone: 228.594.2323 www.egh.ms
STAMPENGINEERARCHITECT
Mississippi Certificate Number E-1969
Dell Consulting project:21-072 Jason A. Matiacio 30457
BGA
JAM 02.18.2022
MAHG11-1042
MAHG111042 BRYAN HALL
RENOVATION
1ST FLOOR PART C PLAN
- DEMOLITION MD105
1/8" = 1'-0"M405MD105
1 1ST FLOOR PART C PLAN - DEMOLITION
N
N
NOT TO SCALE
KEY PLAN
# SHEET NOTES
1 REMOVE EXISTING HVAC SYSTEM IN ITS ENTIRETY INCLUDING DUCTWORK, PIPING,
SUPPORTS, AIR TERMINAL UNITS, AND DIFFUSERS/GRILLES/REGISTERS. REMOVE
CHILLED WATER AND HEATING HOT WATER BRANCH PIPING AND ACCESSORIES.
2 EXISTING AIR HANDLING UNIT SHALL BE TURNED OVER TO THE BASE IN GOOD
CONDITION. CAREFULLY DISCONNECT AND REMOVE AIR HANDLING UNIT FOR
FUTURE REUSE. CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING
OFFICER PRIOR TO DEMOLITION AND MOVE THE AIR HANDLING UNIT TO A
LOCATION ON BASE AS SPECIFIED BY THE CONTRACTING OFFICER.
3 COORDINATE WITH THE BASE CONTRACTING OFFICER AND JOHNSON CONTROLS
PRIOR TO REMOVAL OF ANY HVAC DIRECT DIGITAL CONTROL DEVICES AND
EQUIPMENT. THE FOLLOWING CONTROLS SHALL BE TURNED OVER TO THE BASE
IN GOOD CONDITION FOR FUTURE REUSE: ALL VMA FIELD CONTOLLERS, ALL FEC
FIELD CONTROLLERS, (1x) NAE, (1x) NCE, ALL ZONE DDC THERMOSTATS, AND ALL
H
G
F
14 15 16 17 18 19 20 21 22 23 24 25 26 27
EX. CHILLER TO REMAIN
EX. CONDENSER WATER PUMP TO REMAIN
EX. PRIMARY CHILLED WATER PUMP TO REMAIN
EX. AHU-12
EX. BOILER AND PRIMARY HEATING
HOT WATER PUMP TO REMAIN
/ M
D
1 / MD105
/ M
D
EX. VFD
EX. CHWS&R AND HWS&R
PIPING DN TO CRAWLSPACE
AND UP TO SECOND FLOOR
1 / MD103 1 / MD104
1 / MD104
UP TO MEZZANINE ABOVE
EX. EXH DUCT TO EX. EF ON
ROOF FOR HIGH TEMPERATURE
CONTROL TO REMAIN
EX. HIGH TEMPERATURE
CONTROL AND
REFRIGERANT PURGE EXH
DUCT TO REMAIN
2 3
A B
C D
MEP Engineering
129 E. Government Street Pensacola, FL 32502
P: 850-332-5687 F:850-332-6629
APPROVEDDRAWN
AIR EDUCATION AND TRAINING
COMMAND
DATEREVISION
UNITED STATES AIR
FORCE
MISSISSIPPI