Attachment 4 - ID Factor - 2FA Card Reader.pdf
PDF 982 KB Posted
- Solicitation number
- Not on record
About this file
This is a detailed product specification datasheet for IDFACTORS' 2-Factor Authentication Readers designed for NIST Limited Access Areas. The readers offer flexible, secure access control solutions with multiple interface options including contact, contactless, and dual-interface models compatible with various federal credentials like CAC, PIV, TWIC, and PIV-I. Key technical specifications include support for Wiegand and OSDP output formats, cryptographic algorithms (RSA, ECC, AES), and authentication levels ranging from Level 1 (little confidence) to Level 4 (very high confidence).
The product line features readers with configurable PIN modes, PKI challenge-response capabilities, and optional modules for 125 KHz Prox Cards and FIPS-140 cryptography. Environmental specifications allow for indoor and outdoor installations from -25°F to +130°F, with weatherized design and integration capabilities with major access control systems like Cisco, Honeywell, AMAG, and Lenel. Part numbers are provided for various configurations, including models with different communication protocols (Wiegand/OSDP) and optional cryptographic features, enabling precise selection for specific security requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sources Sought P1102 ESS.pdf | ||
| Sources Sought P1102 ESS.pdf | ||
| Attachment 1 - Response Form.docx | DOCX document | |
| Attachment 2 - Lenel Power Supply Encl.pdf | ||
| Attachment 3 - Altronix Power Supply Encl.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1/8/24, 12:16 PM Readers -new - IDFACTORS https://idfactors.com/allreaders/ 7/16
Download Datasheet
Back to top
2-Factor Contact, Contactless and Dual-Interface Readers for NIST Limited Access Areas.
The most flexible and trusted 2-Factor Readers used by the Federal Government and
Critical Infrastructure.
Available in Contact, Contactless or Dual Interface Models
Indoor or outdoor installation•
Contact slot incorporates a shutter to protect against rain and debris
Optional Dual Technology Module reads 125 KHz Prox Cards https://idfactors.com/allreaders/ 8/16
Configurable PIN to Card, Pin to Panel or pin Pass-through modes
Selectable Wiegand or OSDP modes• Supports CAC, PIV, TWIC, PIV-I, Mifare, DESfire PK-PACS and PACSID
Native CAK challenge-response;
verifies the certificate private key on CAC, PIV, PIV-I and PACSID cards.
Executes CAK verify in 1-Factor Mode and PAK verify in 2-Factor Mode
Optional FIPS-140 Crypto Module for FICAM Compliance
PKI certificates can be compiled (Wiegand) or downloaded (OSDP)
Contact Interface https://idfactors.com/allreaders/ 9/16
Contactless Interface
Dual Interface
Download Datasheet
Back to top
Michael Grosenheider Rectangle
Assurance Level1
Reader Specifications
IDFACTORS, Inc. l 2261 Fifth St. l Berkeley CA 94710 USA l 510.346.1510
Level 1 Level 2 Level 3 Level 4
AUTHENTICATION FACTORS SOME SOME PLUS HIGH VERY HIGH
1-FACTOR (Credential Only)
CONTACT (EntryPointTM) 74-01-1001
CONTACTLESS (EntryPointTM) 74-01-3001
CONTACTLESS w/ PKI CHALLENGE (CAK) (TrustPointTM)
74-01-4000
DUAL INTERFACE (EntryPointTM) 74-01-2002
DUAL INTERFACE w/ PKI CHALLENGE (CAK) (TrustPointTM)
74-01-4012
2-FACTOR (Credential + Pin or PIN)
CONTACTLESS + Pin to System (EntryPointTM) (2) 74-01-3002
CONTACTLESS + Pin to SYSTEM w/ PKI CHALLENGE (TrustPointTM) (2)
74-01-4002
CONTACT + PIN (EntryPointTM) 74-01-1002
CONTACT + PIN w/ PKI CHALLENGE (PAK) (TrustPointTM)
74-01-4001
DUAL INTERFACE: Contactless Mode w/ Pin to SYSTEM (EntryPointTM) (2) 74-01-2003
DUAL INTERFACE: Contact Mode w/ PIN to CARD (EntryPointTM) 74-01-2003
DUAL INTERFACE: Contactless Mode w/ CAK CHALLENGE (TrustPointTM)
74-01-4003
DUAL INTERFACE: Contact Mode w/ PIN to CARD w/ PKI CHALLENGE (TrustPointTM)
74-01-4003
3-FACTOR (Credential + PIN + BIO)
DUAL INTERFACE + PIN + BIO (SURFACE MOUNT) (3)
71-02-2222
DUAL INTERFACE + PIN + BIO w/ PKI CHALLENGE (SURFACE MOUNT) (3)
71-02-3222
STANDARDS SUPPORTED
• ISO 7816 Card-to-Reader Interface • ISO 14443 Contactless Card-to-Reader
Interface • FIPS-201 • NIST 800-76 Biometric Data for PIV • NIST 800-96 Cryptographic Algorithms • NIST 800-116 (Guidance for Use of PIV in PACS)
SMART CARD CREDENTIAL SUPPORT
• CAC End Point
• PIV, TWIC, FRAC, PIV-I (Open Standard)
• IDFACTORS Crypto ID
LOGICAL & CARD READ PERFORMANCE
• T=0, T=1 Contact Interface • Type A and Type B Contactless Interface •
Contactless Read Range: 95+% at 1.5 inches (3.8 cm) • Maximum Read Range: less than 4 inches (10 cm) • Supports Accelerated Transmission Bit Rates 106, 212 and 424 Kbits per second • Default Wiegand format for FASC- N as defined in NIST 800-116 (Agency Code, System Code, Credential Number, Issue Code and Series Issue)
CRYPTOGRAPHIC ALGORITHM SUPPORT
•RSA-1024 •RSA-2048 •ECC-256 •AES 128 & 256 •3DES •SHA-1 •SHA-2
Michael Grosenheider Rectangle
WIEGAND & OSDP OUTPUT SUPPORT
• Wiegand 48 Bit • 56 Bit • 64 Bit • 75 Bit • 128 Bit • 200 Bit
• Contact factory for additional Wiegand format support
• OSDP
PHYSICAL
• High impact weather resistant polycarbonate
• 1 & 2-Factor Dimensions: 9.50” high x 5.00” wide x 2.75” deep
• 3-Factor Dimensions:
• Smart Card Connector rated to 500,000 insertions. Includes protective
Shutter to resist rain & insertion of foreign objects.
• BIO Scanner: Secugen (FIPS-201 Approved)
• Die Cast Metal Keypad
• Lighted Keypad
USER I/O
• 2-Factor: Red, Yellow & Green LED’s
• Audible Speaker for Keypad (Configurable)
• 3-Factor: High Intensity Red LED Display (2 line 16 Character)
ENVIRONMENTAL
• Indoor or Outdoor
• -25 F to +130 F (-32 C to + 66 C)
• UL rain tested design
• 95% relative humidity (non-condensing)
• Weatherized shield recommended for outdoor installations
ACCESS SYSTEM INTEGRATION
• Cisco •Quintron • •Honeywell Vindicator
• AMAG •Genetec •Lenel •Software House
• Andover •Galaxy •Sielox
• Call Factory for Other System Integrations
READER I/O PORTS
•Access System: RJ-45 & Standard Terminal Block •Programming: USB Connector (Printer Type Cable)
MODE CONTROL
• 2-Factor Readers: 1-Factor to 2-Factor Mode controlled by LED2
Line switched from Panel
• 3-Factor Readers: 1-Factor to 2-Factor & 3-Factor Mode is controlled by LED2 Line and 1 AUX relay from panel
ELECTRICAL
• Input: 12 - 18 Volt DC; 350 mA @ 12 VDC
CONFIGURABLE PERFORMANCE FEATURES
•Audible Keypad ON/OFF Control • LED Flashing Mode • Duress Alarm •PIN to Card or Pin to System •Multiple Output Formats based on Card Type
INSTALLATION
•1 & 2-Factor Readers: Mounting Plate Included (select 4 screws appropriate for wall material) or Single-Gang Wall Box •3-Factor Readers: Stainless Steel Mounting Plate Included (select 4 screws appropriate for wall material) or Double-Gang Wall Box.
Integrated 1/2" Conduit receiving port eliminates need for Condit Box.
NOTES
(1) ASSUARANCE LEVEL from OMB 04-04 & NIST 800-116 (1)
Level 1 = Little or Some confidence in the asserted identity
Level 2 = Some Plus confidence in the asserted identity
Level 3 = High Confidence in the asserted identity
Level 4 = Very High Confidence in the asserted identity
(2) Pin to System is not a recognized Use Case by OMB, FISMA, NIST or FICAM
(3) BIO match requires Contact Interface to enter PIN for 3-Factor Authentication
DEFINITIONS
PIN: Indicates PIN is Sent to the Credential in Contact Mode per FIPS-201 and NIST 800-116 Guidance Pin: Indicates Pin is sent to System Controller in Contactless Mode (Not Recognized by Federal Guidance). It should be noted that the User's PIN to credential is personal information and must not be stored in any database including a PACS. This means that a Pin must be different than the User's PIN for the credential which introduces multiple pins for the User to remember.
CAK: Card Authentication Key Challenge - Does not Require Pin Entry and can be Contactless or Contact
PAK: Personal Authentication Key Challenge - Requires PIN Entry in Contact Mode to Activate Private Key
File details come from the government source that posted it. Updated .