Attachment 4 - Cascade Wind Tunnel (CWT) Photos.pdf
PDF 2 MB Posted
- Attached to
- USAFA - Cascade Wind Tunnel Removal
- Solicitation number
- FA700026Q0058
About this file
This document is a photographic record of the Cascade Wind Tunnel (CWT) removal project, containing 16 images documenting the facility's condition and components prior to decommissioning.
The photographs provide comprehensive visual documentation of the wind tunnel facility, including entrance hallway views, external structural elements of the main test chamber (front left side, corners, and walkways), internal components such as the middle section piping and ducting systems, interior test chamber views, and rear structural sections. Additional images detail the chiller unit (a Liebert model VH412WHAA0l with specifications including 460-volt, 3-phase, 60-hertz power requirements, serial number 693180-001, and R-22 refrigerant), its physical placement and connections to associated ductwork, and the building utility piping that requires capping. The documentation concludes with exit corridor views showing the facility's access points. The images collectively illustrate the scale, complexity, and interconnected systems of the CWT facility, including white composite structural panels, internal piping networks with yellow safety markings, test equipment with red and white coverings, control systems, and overhead ductwork arrangements. This photographic set appears designed to support the planning and execution of facility removal, demolition, or salvage operations by providing detailed visual reference of existing conditions and component locations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Cascade Wind Tunnel (CWT Removal Photos)
Photo 1 – Entrance View of Hallway to CWT Facility
Photo 2 (Left) – Front Left Side of CWT Photo 3 (Right) – Front Left Corner Walkway and CWT
Photo 4 – Cascade Wind Tunnel Middle Section and Internal Piping
Photo 5 (Left) – Left Side and Pipe Connection Photo 6 (Right) – Left Middle of CWT
Photo 7 – Middle Right of CWT and Piping
Photo 8 – CWT Interior
Photo 9 – Backside of CWT
Photo 10 – Side View of Chiller Unit
Photo 11 – Front View of Chiller Unit and Attachment to Duct Work
Photo 12 – Chiller Unit Information
Photo 13 – Duct Work and Chiller Unit
Photo 14 – Duct Work Wall View
Photo 15 – Building Utility Piping to be Capped
Photo 16 – Exit View of Doorway and Hallway
| Slide 1: Cascade Wind Tunnel (CWT Removal Photos) |
| Slide 2: Photo 1 – Entrance View of Hallway to CWT Facility |
| Slide 3: Photo 2 (Left) – Front Left Side of CWT Photo 3 (Right) – Front Left Corner Walkway and CWT |
| Slide 4: Photo 4 – Cascade Wind Tunnel Middle Section and Internal Piping |
| Slide 5: Photo 5 (Left) – Left Side and Pipe Connection Photo 6 (Right) – Left Middle of CWT |
| Slide 6: Photo 7 – Middle Right of CWT and Piping |
| Slide 7: Photo 8 – CWT Interior |
| Slide 8: Photo 9 – Backside of CWT |
| Slide 9: Photo 10 – Side View of Chiller Unit |
| Slide 10: Photo 11 – Front View of Chiller Unit and Attachment to Duct Work |
| Slide 11: Photo 12 – Chiller Unit Information |
| Slide 12: Photo 13 – Duct Work and Chiller Unit |
| Slide 13: Photo 14 – Duct Work Wall View |
| Slide 14: Photo 15 – Building Utility Piping to be Capped |
| Slide 15: Photo 16 – Exit View of Doorway and Hallway |
File details come from the government source that posted it. Updated .