1258 Boiling Springs Road • Spartanburg, SC 29303 • Phone 864‐541‐8736 / Fax 864‐541‐8776 www.crossroadsenv.net
LIMITED ASBESTOS INSPECTION REPORT
FOR
CLIENT SERVICES
Francis Marion & Sumter National Forest
4931 Broad River Road Columbia, SC 29212
SITE LOCATION
Lick Fork Lake Recreation Park State Hwy. S‐19‐392 Edgefield, SC 29824
INSPECTION DATE: March 11, 2020 REPORT DATE: March 18, 2020
INSPECTOR
Kay H. Horton – SC‐DHEC License #ASB‐23394
(864) 541‐8736
For
Crossroads Environmental, LLC 1258 Boiling Springs Road
Spartanburg, South Carolina 29303
(864) 541‐8736
CRE Project # 17946‐IN
TABLE OF CONTENTS
INSPECTION REPORT/LETTER
BACKGROUND INFORMATION
BUILDING/AREA DESCRIPTION
INSPECTION STRATEGY/SAMPLING PROTOCOL
RESULTS
CLOSING STATEMENTS AND LIMITATIONS
ATTACHMENTS
ATTACHMENT I: ASBESTOS SUMMARY TABLE
ATTACHMENT II: LABORATORY REPORT
ATTACHMENT III: BUILDING/AREA SKETCH
ATTACHMENT IV: INSPECTOR’S LICENSE/ACCREDITATION
March 18, 2020
Mr. Mike Alcorn Forest Service 4931 Broad River Road Columbia, SC 29212
Re: Limited Asbestos Inspection Report Lick Fork Lake Recreation Site
State Hwy. S‐19‐392, Edgefield, SC 29824 CRE Project Number: 17946‐IN
Dear Mr. Alcorn:
Crossroads Environmental, LLC (CRE) completed a comprehensive asbestos inspection of two (2) structures within the Lick Fork Lake Recreation Park, located at State Highway South‐19‐392 in Edgefield, South Carolina on March 18, 2020. The inspection was performed by a SC‐DHEC Licensed Asbestos Inspector, and in accordance with South Carolina Department of Health and Environmental Control (SC‐DHEC) and Environmental Protection Agency (EPA) Requirements. A detailed summary table of the sampling is included in Attachment I; however, this report should be read in its entirety.
Building Description
CRE’s scope of work included sampling suspect material in association with the former pump house (Bldg. 810), and “day use” bath house (Bldg. Bldg. 809) within the Lick Fork Lake Recreation Park. Both buildings are of cinder block construction. The pump house has a shingled roof, and the bath house has a metal roof over felt underlayment. The only materials identified within the pump house and “day use” bath house were roofing material on both roofs, and caulk/filler around one toilet in the bath house. While on site, the 10,000 gallon cistern, which is located by the pump house, was inspected. It is of concrete construction with a metal hatch. No suspect asbestos‐containing materials were identified in association with the cistern.
Inspection Strategy/Sampling Protocol
The inspection consisted of grouping suspect asbestos containing materials into homogeneous areas based on the color and texture of the material, and then performing representative sampling of the materials included in those homogeneous
Limited Asbestos Inspection Report March 18, 2020 Lick Fork Lake Recreation Park Page 2 of 2 Project Number: 17946‐IN areas. SC‐DHEC has requirements for the minimum number of samples that can be collected from each homogeneous area (three samples of each miscellaneous material, three samples of each type of thermal system insulation, and the sample requirements for surfacing are based on square footage). Following completion of the on‐site inspection/sampling, samples were submitted to an accredited laboratory for analysis.
Results
EPA recognizes a material as Asbestos Containing Material (ACM) if an asbestos content of greater than one percent asbestos is detected in a representative sample analyzed by polarized light microscopy.
Results indicated that no asbestos was detected in the materials sampled.
Closing Statements and Limitations
Every effort was made to identify all materials in accessible areas. There is the possibility that suspect materials were not identified in inaccessible areas. If any suspect material is discovered that is not included within this report, it should be sampled before it is physically disturbed.
This document has been prepared by Crossroads Environmental, LLC at the request of and for the exclusive use of the Forest Service. This report represents the findings from the date that it was inspected, and is limited in scope to that indicated above.
Crossroads Environmental, LLC appreciates the opportunity to provide the Forest Service with our consultative services. Should you have any questions or need additional information, please do not hesitate to contact us.
Sincerely, Kay Horton President
HJ
Attachments‐ (4)
ATTACHMENT I
ASBESTOS SUMMARY TABLE
CRE JOB #: 17946‐IN
Location:
Client: DATE: 3/11/2020
HA#
Type of
Material
TSI, Surf, Misc.
Material Type Sample Number
Asbestos
Content
(PLM)
Asbestos
Content
(TEM)
Location of
Sample
Approx.
Quantity
Physical
Condition Location/ Comments
161‐Shingle
161‐Felt
NAD
NAD
Old Pump House
162‐Shingle
162‐Felt
NAD
NAD
Old Pump House
163‐Shingle
163‐Felt
NAD
NAD
Old Pump House
164 NAD /
"Day Use" Bath
House
165 NAD /
"Day Use" Bath
House
166 / NAD
"Day Use" Bath
House
167 NAD /
"Day Use" Bath
House
168 NAD /
"Day Use" Bath
House
169 NAD /
"Day Use" Bath
House
Located in the women's restroom of the "day use" bath house.
03 Misc.
Felt Paper Under
Metal Roof N/A N/A
Located on the roof of the "day use" bath house.
02 Misc. N/A
Misc.
Roofing Shingles &
Felt Paper
Caulk/Filler
Around Toilet N/A
N/A
CROSSROADS ENVIRONMENTAL, LLC ASBESTOS INSPECTION REPORT
Lick Fork Lake Recreation Park; State Hwy S‐19‐392, Edgefield, SC 29824
Francis Marion & Sumter National Forest
Key: A=Amosite, C=Chrysotile, Cr=Crocidolite, Tr=Tremolite, Ac=Actinolite Asbestos, Misc.=Miscellaneous, HA#=Homogeneous Area #, PLM=Polarized Light Microscopy, TEM=Transmission Electron Microscopy, /=PLM and/or TEM Analysis Not Required sq.ft.=Square Feet, cu.ft.=Cubic Feet, ln.ft.=Linear Feet, HJI=Hard Joint Insulation, TSI=Thermal System Insulation, BUR=Built‐up Roofing, Surf=Surfacing
NAD=No Asbestos Detected, SP=Stop Positive
Located on the roof of the picnic area pump house.
N/A
Asbestos Inspector's Accreditation #: ASB-23394 Asbestos Inspector Printed Name: Kay H. Horton Page 1 of 1
ATTACHMENT II
LABORATORY REPORT(S)
March 16, 2020
Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
CLIENT PROJECT: Lick Fork Lake, 17946-IN
CEI LAB CODE: A203264
Dear Customer:
Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on March 13, 2020. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.
Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.
Thank you for your business and we look forward to continuing good relations.
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Tianbao Bai, Ph.D., CIH Laboratory Director
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Polarized Light Microscopy
Prepared for
Crossroads Environmental
CLIENT PROJECT:
LAB CODE:
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORT DATE:
TOTAL SAMPLES ANALYZED:
# SAMPLES >1% ASBESTOS:
Lick Fork Lake, 17946-IN
A203264
03/16/20
Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY
PROJECT: Lick Fork Lake, 17946-IN LAB CODE: A203264
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
Layer 1 A51601 Brown,Black Roof Shingle None Detected161
Layer 2 A51601 Black Felt None Detected
Layer 1 A51602 Brown,Black Roof Shingle None Detected162
Layer 2 A51602 Black Felt None Detected
A51603 Sample Submitted for TEM Analysis
A51604 Gray Caulk/filler None Detected164
A51605 Gray Caulk/filler None Detected165
A51606 Sample Submitted for TEM Analysis
A51607 Black Felt Paper None Detected167
A51608 Black Felt Paper None Detected168
A51609 Black Felt Paper None Detected169
ASBESTOS BULK ANALYSIS
Lab Code: A203264 Date Received: 03-13-20 Date Analyzed: 03-13-20 Date Reported: 03-16-20
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
Project: Lick Fork Lake, 17946-IN
Fibrous
Brown,Black
A51601
20%Homogeneous
Fibrous Bound
45% 35%
Fiberglass Tar Silicates
None Detected Layer 1
Roof Shingle
Black Felt
A51601 75%Homogeneous
Fibrous Bound
25%Cellulose Tar None DetectedLayer 2
Brown,Black
A51602
20%Homogeneous
Fibrous Bound
45% 35%
Fiberglass Tar Silicates
None Detected Layer 1
Roof Shingle
Black Felt
A51602 75%Homogeneous
Fibrous Bound
25%Cellulose Tar None DetectedLayer 2
Sample Submitted for TEM Analysis
A51603
Gray Caulk/filler164
A51604 Homogeneous
Non-fibrous Bound
100% Binder None Detected
Gray Caulk/filler165
A51605 Homogeneous
Non-fibrous Bound
100% Binder None Detected
Sample Submitted for TEM Analysis
A51606
Lab Code: A203264 Date Received: 03-13-20 Date Analyzed: 03-13-20 Date Reported: 03-16-20
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
Project: Lick Fork Lake, 17946-IN
Fibrous
Black Felt Paper167
A51607 85%Homogeneous
Fibrous Bound
15%Cellulose Tar None Detected
Black Felt Paper168
A51608 85%Homogeneous
Fibrous Bound
15%Cellulose Tar None Detected
Black Felt Paper169
A51609 85%Homogeneous
Fibrous Bound
15%Cellulose Tar None Detected
LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORTING LIMIT: <1% by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points
REGULATORY LIMIT: >1% by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH
Greg Ruff
March 16, 2020
Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
CLIENT PROJECT: Lick Fork Lake, 17946-IN
LAB CODE: T200621
Dear Customer:
Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on March 13, 2020. The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method.
Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method is <1% depending on the processed weight and constituents of the sample.
Thank you for your business and we look forward to continuing good relations.
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Tianbao Bai, Ph.D., CIH
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Transmission Electron Microscopy
Prepared for
Crossroads Environmental
CLIENT PROJECT:
LAB CODE:
TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 Sec. 2.5.5.1
REPORT DATE:
Lick Fork Lake, 17946-IN
T200621
03/16/20
By: TRANSMISSION ELECTRON MICROSCOPY
Lab Code: T200621 Date Received: 03-13-20 Date Analyzed: 03-16-20 Date Reported: 03-16-20
Client ID Lab ID
Material Description
TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1
Client: Crossroads Environmental 1258 Boiling Springs Road Spartanburg, SC 29303
Project: Lick Fork Lake, 17946-IN
Sample Weight
(g)
Organic Material
Acid Soluble Material
Acid Insoluble Material
Asbestos
T03553 163 Roof Shingle 0.564 18.8 47.7 33.5 None
Detected
T03554 163 Felt 0.592 96.6 2.5 .9 None
Detected
T03555 166 Caulk/filler 0.413 19.6 29.5 50.9 None
Detected
LEGEND: None
METHOD: CHATFIELD & EPA/600/R-93/116 Sec. 2.5.5.1
LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)
REGULATORY LIMIT: >1% by weight
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request. Samples were received in acceptable condition unless otherwise noted.
Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH
Emily Morris
ATTACHMENT III
SAMPLE LOCATION SKETCH AND/OR PHOTOS
ATTACHMENT IV
ACCREDITATION(S)
| Title Page and TOC |
| SC inspection letter |
| ATTACHMENT I Asbestos |
| SC Asbestos Table |
| ATTACHMENT II Reports |
| A203264 |
| A203264_3_16_2020_9_34_22_Asbestos_Report |
| A203264 |
| T200621 |
| T200621_3_16_2020_11_19_57_TEM_Bulk_Chatfield_PLUS_Analysis_Worksheets_Report |
| T200621 |