1258 Boiling Springs Road • Spartanburg, SC 29303 • Phone 864-541-8736 / Fax 864-541-8776 www.crossroadsenv.net
ASBESTOS INSPECTION REPORT
FOR
CLIENT
Francis Marion & Sumter National Forest
4931 Broad River Road Abbeville, SC 29620
SITE LOCATION
Woods Ferry Campground
Structures Scheduled for Demolition Carlisle, SC 29031
INSPECTION DATE: March 19, 2020 REPORT DATE: March 24, 2020
INSPECTOR
Evans Harris – SC-DHEC License #BI-01224
(864) 541-8736
For
Crossroads Environmental, LLC 1258 Boiling Springs Road
Spartanburg, South Carolina 29303
(864) 541-8736
CRE Project # 17965-IN
TABLE OF CONTENTS
INSPECTION REPORT/LETTER
• BACKGROUND INFORMATION
• BUILDING/AREA DESCRIPTION
• INSPECTION STRATEGY/SAMPLING PROTOCOL
• RESULTS
• RELEVANT REGULATORY REQUIREMENTS/RECOMMENDATIONS
• CLOSING STATEMENTS AND LIMITATIONS
ATTACHMENTS
• ATTACHMENT I: ASBESTOS SUMMARY TABLE
• ATTACHMENT II: LABORATORY REPORT
• ATTACHMENT III: BUILDING/AREA SKETCH
• ATTACHMENT IV: INSPECTOR’S LICENSE/ACCREDITATION
March 24, 2020
Mr. Mike Alcorn Forest Service Francis Marion & Sumter National Forest Service 4931 Broad River Road Columbia, SC 29212
Re: Asbestos Inspection Report Woods Ferry Campground (Structures to be Demolished)
Carlisle, SC 29031 CRE Project Number: 17965-IN
Dear Mr. Alcorn:
Crossroads Environmental, LLC (CRE) completed asbestos inspections of multiple structures within Woods Ferry Campground, located in Carlisle, South Carolina on March 19, 2020. The inspection was performed by a SC-DHEC Licensed Asbestos Inspector, and in accordance with South Carolina Department of Health and Environmental Control (SC-DHEC) and Environmental Protection Agency (EPA) Requirements. A detailed summary table of the sampling is included in Attachment I;
however, this report should be read in its entirety.
Building Description
CRE’s scope of work included sampling suspect material(s) associated with the ‘Pump House/Storage Tank’ (Bldg. 724), ‘Loop A Bath House’ (Bldg. 714), and ‘Loop B Bath House’ (Bldg. 715). The ‘Pump House/Storage Tank’ structure is of concrete construction, but features silver coating on the flat, concrete roof and a skim/paint layer on the exterior sides of the storage tank structure. The ‘Loop A Bath House’ and ‘Loop B Bath House’ are identical structures. They feature CMU construction, with a flat, tar and felt roof. There is a suspect skim coat over the interior CMU walls within the men’s and women’s restrooms of both structures.
Inspection Strategy/Sampling Protocol
The inspection consisted of grouping suspect asbestos containing materials into homogeneous areas based on the color and texture of the material, and then performing representative sampling of the materials included in those homogeneous areas. SC-DHEC has requirements for the minimum number of samples that can be
Asbestos Inspection Report March 24, 2020 Wood Ferry Campground (Structures to be Demolished) Page 2 of 3 Project Number: 17965-IN collected from each homogeneous area (three samples of each miscellaneous material, three samples of each type of thermal system insulation, and the sample requirements for surfacing are based on square footage). Following completion of the on-site inspection/sampling, samples were submitted to an accredited laboratory for analysis.
As of June 27, 2008, SC-DHEC requires that any non-friable organically bound (NOB) material that is suspect to contain asbestos, such as floor tile, mastics, roofing material, and caulking must be analyzed by transmission electron microscopy (TEM) if polarized light microscopy (PLM) analyses of that material indicate that no asbestos was detected.
Results
EPA recognizes a material as Asbestos Containing Material (ACM) if an asbestos content of greater than one percent asbestos is detected in a representative sample analyzed by polarized light microscopy.
Results indicated that greater than one percent asbestos was detected in the silver coating on the tops of the ‘Pump House/Storage Tank’ structure; and the interior wall CMU skim coat in the men’s and women’s restrooms of the ‘Loop A’ and ‘Loop B’ ‘Bath House(s)’.
Relevant Regulatory Requirements/Recommendations
Friability-Friable materials are defined as materials that can be reduced to powder by hand pressure. It should be noted that non-friable materials may become friable depending on the method of removal. All non-friable materials must be removed by properly accredited asbestos personnel. If the non-friable materials are removed in a friable manner, then all regulations in regards to friable abatement will apply, and the abatement must be performed by a SC-DHEC Licensed Asbestos Contractor, and in accordance with all state and federal regulations.
Air Monitoring-Air monitoring by a SC-DHEC Licensed Air Monitor will be required on this project.
CRE can further assist with Project Design, Air Monitoring, and/or help in selecting an asbestos abatement contractor.
Closing Statements and Limitations
Every effort was made to identify all materials in accessible areas. There is the possibility that suspect materials were not identified in inaccessible areas. If any
Asbestos Inspection Report March 24, 2020 Wood Ferry Campground (Structures to be Demolished) Page 3 of 3 Project Number: 17965-IN suspect material is discovered that is not included within this report, it should be sampled before it is physically disturbed.
This document has been prepared by Crossroads Environmental, LLC at the request of and for the exclusive use of the Forest Service. This report represents the findings from the date that it was inspected, and is limited in scope to that indicated above.
Crossroads Environmental, LLC appreciates the opportunity to provide the Forest Service with our consultative services. Should you have any questions or need additional information, please do not hesitate to contact us.
Sincerely, Evans Harris Licensed Inspector
Kay Horton President
Attachments- (4)
ATTACHMENT I
ASBESTOS SUMMARY TABLE
Asbestos Inspector's Accreditation #: BI-01224 Asbestos Inspector Printed Name: Evans Harris Page 1 of 2
CRE JOB #: 17965-IN
Location:
Client: DATE: 3/19/2020
HA#
Type of Material TSI, Surf, Misc.
Material Type Sample Number Asbestos Content
(PLM)
Asbestos Content
(TEM)
Location of Sample
Approx.
Quantity
Physical Condition
Location/ Comments
001 3%C / NW Pump House
002 S/P / NE Pump House
003 / S/P West storage tank
004 NAD / SE side
005 NAD / NW side
006 NAD / NE side
007 3%C / North wall, Men's restroom
008 S/P / East wall, Men's restroom
009 S/P / South wall, Women's restroom
010 Tar 010 Felt
NAD
NAD
NW corner over Men's restroom
011 Tar 011 Felt
NAD
NAD
NW corner over Men's restroom
012 Tar 012 Felt
NAD
NAD
NW corner over Men's restroom
013 3%C / West wall, Men's restroom
014 S/P / East wall, Women's restroom
015 S/P / West wall, Women's restroom
04 Misc Tar & Felt Roofing N/A Good; Non-
Friable Located as roof field over the 'Loop A Bath House'.
03 Surf CMU Skim Coat ≈600 sq. ft.
Minor
Damage;
Friable
Located on the CMU interior walls of the men's and women's restrooms in the 'Loop A Bath House'.
02 Surf Paint/Skim Coat N/A Damaged;
Friable Located on the exterior sides of the 'Storage Tank' structure.
01 Surf Silver Coating ≈350 sq. ft.
Damaged;
Friable
Located on the top(s) of the 'Pump House/Storage Tank' structure.
Please Note: Material is not consistent throughout, and does not cover the surfaces entirely.
05 Surf CMU Skim Coat ≈600 sq. ft.
Minor
Damage;
Friable
Located on the CMU interior walls of the men's and women's restrooms in the 'Loop B Bath House'.
CROSSROADS ENVIRONMENTAL, LLC ASBESTOS INSPECTION REPORT
Wood Ferry Campground- Pump House/Storage Tank, Loop A Bath House, Loop B Bath House
Francis Marion & Sumter Forest Service
Key: A=Amosite, C=Chrysotile, Cr=Crocidolite, Tr=Tremolite, Ac=Actinolite Asbestos, Misc.=Miscellaneous, HA#=Homogeneous Area #, PLM=Polarized Light Microscopy, TEM=Transmission Electron Microscopy, /=PLM and/or TEM Analysis Not Required sq.ft.=Square Feet, cu.ft.=Cubic Feet, ln.ft.=Linear Feet, HJI=Hard Joint Insulation, TSI=Thermal System Insulation, BUR=Built-up Roofing, Surf=Surfacing NAD=No Asbestos Detected, SP=Stop Positive
Asbestos Inspector's Accreditation #: BI-01224 Asbestos Inspector Printed Name: Evans Harris Page 2 of 2
CRE JOB #: 17965-IN
Location:
Client: DATE: 3/19/2020
HA#
Type of Material TSI, Surf, Misc.
Material Type Sample Number Asbestos Content
(PLM)
Asbestos Content
(TEM)
Location of Sample
Approx.
Quantity
Physical Condition
Location/ Comments
CROSSROADS ENVIRONMENTAL, LLC ASBESTOS INSPECTION REPORT
Wood Ferry Campground- Pump House/Storage Tank, Loop A Bath House, Loop B Bath House
Francis Marion & Sumter Forest Service
Key: A=Amosite, C=Chrysotile, Cr=Crocidolite, Tr=Tremolite, Ac=Actinolite Asbestos, Misc.=Miscellaneous, HA#=Homogeneous Area #, PLM=Polarized Light Microscopy, TEM=Transmission Electron Microscopy, /=PLM and/or TEM Analysis Not Required sq.ft.=Square Feet, cu.ft.=Cubic Feet, ln.ft.=Linear Feet, HJI=Hard Joint Insulation, TSI=Thermal System Insulation, BUR=Built-up Roofing, Surf=Surfacing NAD=No Asbestos Detected, SP=Stop Positive
016 Tar 016 Felt
NAD
NAD
SW roof section
017 Tar 017 Felt
NAD
NAD
SW roof section
018 Tar 018 Felt
NAD
NAD
SW roof section
N/A Good; Non-
Friable Misc Tar & Felt Roofing06
Located as roof field over the 'Loop B Bath House'.
ATTACHMENT II
LABORATORY REPORT(S)
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E, App.E
17965-INProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Kay HortonAttn:Customer: Crossroads Environmental LLC 1258 Boiling Springs Rd Spartanburg, SC 29303
Analysis ID: 71939127_PLM
Date Reported: 3/21/2020
Date Received: 3/20/2020
Lab Order ID: 71939127
3% Chrysotile
Silver paint/Coating
Silver Non Fibrous Heterogeneous
Dissolved71939127PLM_1
Other 97%
Not Analyzed
Silver paint/Coating
71939127PLM_2
Not Analyzed
Silver paint/Coating
71939127PLM_3
None Detected
Exterior paint/Skim Tan Non Fibrous Heterogeneous
Ashed71939127PLM_4
Other 100%
None Detected
Exterior paint/Skim Tan Non Fibrous Heterogeneous
Ashed71939127PLM_5
Other 100%
None Detected
Exterior paint/Skim Tan Non Fibrous Heterogeneous
Ashed71939127PLM_6
Other 100%
CMU Skim
Cream Non Fibrous Heterogeneous
Crushed71939127PLM_7
Other 97%
Not Analyzed
CMU Skim
71939127PLM_8
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Jalen Moore (24)
P-F-002 r15 1/16/2021
EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E, App.E
17965-INProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Kay HortonAttn:Customer: Crossroads Environmental LLC 1258 Boiling Springs Rd Spartanburg, SC 29303
Analysis ID: 71939127_PLM
Date Reported: 3/21/2020
Date Received: 3/20/2020
Lab Order ID: 71939127
Not Analyzed
CMU Skim
71939127PLM_9
None Detected 010 - A
Tar & Felt Roofing tar
Black Non Fibrous Heterogeneous
Dissolved71939127PLM_10
Other 100%
None Detected 010 - B
Tar & Felt Roofing felt
Black Non Fibrous Heterogeneous
Ashed71939127PLM_19
Cellulose Other 40% 60%
None Detected 011 - A
Tar & Felt Roofing tar
Black Non Fibrous Heterogeneous
Dissolved71939127PLM_11
Other 100%
None Detected 011 - B
Tar & Felt Roofing felt
Black Non Fibrous Heterogeneous
Ashed71939127PLM_20
Cellulose Other 40% 60%
Not Analyzed 012 - A
Tar & Felt Roofing tar - TEM
71939127PLM_12
Not Analyzed 012 - B
Tar & Felt Roofing felt - TEM
71939127PLM_21
CMU Skim
Cream Non Fibrous Heterogeneous
Crushed71939127PLM_13
Other 97%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E, App.E
17965-INProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Kay HortonAttn:Customer: Crossroads Environmental LLC 1258 Boiling Springs Rd Spartanburg, SC 29303
Analysis ID: 71939127_PLM
Date Reported: 3/21/2020
Date Received: 3/20/2020
Lab Order ID: 71939127
Not Analyzed
CMU Skim
71939127PLM_14
Not Analyzed
CMU Skim
71939127PLM_15
None Detected 016 - A
Tar & Felt Roofing tar
Black Non Fibrous Heterogeneous
Dissolved71939127PLM_16
Other 100%
None Detected 016 - B
Tar & Felt Roofing felt
Black Non Fibrous Heterogeneous
Ashed71939127PLM_22
Cellulose Other 40% 60%
None Detected 017 - A
Tar & Felt Roofing tar
Black Non Fibrous Heterogeneous
Dissolved71939127PLM_17
Other 100%
None Detected 017 - B
Tar & Felt Roofing felt
Black Non Fibrous Heterogeneous
Ashed71939127PLM_23
Cellulose Other 40% 60%
Not Analyzed 018 - A
Tar & Felt Roofing tar - TEM
71939127PLM_18
Not Analyzed 018 - B
Tar & Felt Roofing felt - TEM
71939127PLM_24
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
CROSSROADS ENVIRONMENTAL, LLC Page _ \ of _l_ Sample Chain of Custody Date Sent: ~ L lC\ L ~O 1258 Boiling Springs Road Project ID#: t ~h5- :CN Spartanburg, SC 29303 Submitted to: t,A-I Phone(864)541-8736 Number of Samples: ,~ E ~,1\ C'.A-i ~---
~ ;al\ tor ~•IV
Fax Results:
resul~rossroadsenv.net Shipping Info: # - ~
Ty~ofAna~ T~~round:
2 PLM .-, r, .-, r, .-, t...=...I ~ L-...J L-...J L-...J L-...J L..:J L-...J L-...J
24HR ~ 48HR 72HR 5Day PCM PLM TEM AAS Other Other:
Air Bulk Air Chips/
Bulk / Wipes_ S~al Instructions:
Water_ Stop Positive D PLM any layers not TEM'd
Sample ID# DESCRIPTION OF SAMPLE COMMENTS oo, L.:.\ '°" P~-~ Jr ~Ji ~.wo ft.AIL oo;).. J I o o"b ' oo\..,, -C: v-6..r-~cw-.P.n-::_-0- J st-~"' oo<S ' OOb J., 001 (.Mu L:.. r-,N\.
om gO(u " ~ 0\0 T~~~ ~-f-, f\.O.
0\) J 'l/
O\."}. ,i.,, ~M.
\{)\!) L./1.A I J. '5 t::, IV\,_ \J\,M
Ol~
O\~ ,I/
Q\\o T oA" J. F-~ ~f,/\..Q o, 1 I
_J
O\.t ..J.., n r 1fM t Accepteo t::U :
Signature & Date of Handlers:
Relinquished By: /J .4JA LJWtil ~ ~cted U
Received By:
Relinquished By: v Received By:
Relinquished By: Received By:
White: Lab Yellow: File
~ ~~ (0?).f>~
CRE FORM 10-002
REORDER FROM ACTION PRINTING 864.585.9581
3/21/2020 Project: 17965-IN
Lab Order ID: 71939177
Lab Notes
Description
Lab Sample ID
Sample ID
Semi-Quantitative Chatfield SOP 1988-02 Rev. 1
Asbestos LCL-UCL
(Wt. %)
Bulk Asbestos Analysis by Transmission Electron Microscopy
Date Received:
3/24/2020Date Reported:
Crossroads Environmental LLC 1258 Boiling Springs Rd Spartanburg, SC 29303
Customer:
Analysis ID: 71939177_TB
Attn: Evans Harris
Acid Sol.
Organic
(Wt. %)(Wt. %) (Wt. %)
None Detected-98%
012-A
71939177TBS_1
Tar & felt roofing tar
None Detected-100%
012-B
71939177TBS_2
Tar & felt roofing felt
None Detected-60.%
018-A
71939177TBS_3
Tar & felt roofing tar
None Detected-99%
018-B
71939177TBS_4
Tar & felt roofing felt
Daniel Schwartz (4)
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Approved Signatory
Page 1 of 1tem_2.2.001
Analyst
Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.
T-F-010 r15 1/15/2018 r'\ r\ r\ t /tf ~61111
[ Page-1.. of _L CROSSROADS ENVIRONMENTAL, LLC
, Sample Chain of Custeqy Date Sent: ?2 L \~ l ~O 1258 Boiling Springs Road Project ID#: \ ~bS- :c.JJ Spartanburg, SC 29303 · Submitted to: 68':I Ph<l>ne (864.) 541.-8736 ~ Number of Sampl~s: \t;&
Fax Results: I ~ ;{;,~ ·· - •V J ul . crossreads.env.net Shipping Info: I # .. -- -........ -- I
Ty~ofAn~ef T~round~
2 f>l,M I i.=.J y.JA L....../ L..J L..J L-.1 L.:;;.J L-.1 L..J
24HR "'( 48Hr 72HR 5Day PCM PLM TEM AAS Other Other:
Air Bulk Air Chips/
S~al lnstruJions: Bulk 7 Wipes_ Water_ Stop Positive D P!.M any layers not TEM'.d
Sample ID# DESCRIPTION OF SAMPLE COMMENTS
00\ ~, ,D,C ~A Jr _.,i\ • : ....... ft.All - J ool oo'?, '
OOy -c vb .r-~ Qf"'.P; _-0- J £> r ,
- oo<S \
OOb -1- 00'1 (_M.u ~ ~-.N'\.
00"/J QO(v ..,, ., 0\0 T oA- t .... o-G- P.oo--t=-,NO.
J I
0\ l ~I/
0\ "'). 'i., ~M.
\O\") L.M I L "5 t: "; N\. - .. \J\..M Ol"'\
O\~ .. v o\\? T ~ J. FeR!z ~f, l\,Q
01...1 .J ' '=I, O'-l/:, ,L,, rh 1£M t Acc~ptea ti.I
Signature & Date of Handlers: R~cted U · · Rel\nqu!shed By: /) .AJA 1Jba.tli Lt ReceivedBy: (
1 1.- ~h,o cv:3V~ Relrnqu,shed By: · v Received By: ~ f
Relinquished By: Received By: I I
White: Lab Yellow: File . 4
CRE FORM 1!><: ., ·RE(l!{DER FROM ACTION PRINTING 864.585.9!
ATTACHMENT III
SAMPLE LOCATION SKETCH AND/OR PHOTOS
ATTACHMENT IV
ACCREDITATION(S)
| Title Page and TOC 17965 |
| SC inspection letter 17965 |
| ATTACHMENT I Asbestos |
| ASBESTOS SUMMARY TABLE |
| SC Asbestos Table 17965 |
| Sheet1 |
| ATTACHMENT II Reports |
| LABORATORY REPORT(S) |
| 71939127_PLM |
| 71939177_TBS |
| ATTACHMENT III Sketch-Photo SC |
| SAMPLE LOCATION SKETCH AND/OR PHOTOS |
| Sketch Loop A 17965 |
| Sketch Loop B 17965 |
| Sketch Pump House 17965 |
| ATTACHMENT IV SC License |
| ACCREDITATION(S) |
ConsultBI_ConsultPD_Air Sampler_Exp.09-15-20
File details come from the government source that posted it. Updated .