This is Attachment 3 to a federal contract solicitation containing photographs and documentation of existing roof conditions for Building 2-3 at the North Central Soil Conservation Research Laboratory (NCSCRL), a USDA-ARS facility located in Morris, Minnesota. The photographs, taken in March 2025, document the current state of the roof requiring replacement and serve as reference materials for contractors developing bids and proposals. The attachment includes exterior roof views showing deteriorated conditions, ponding water, damaged membrane material, and compromised flashing, along with close-up detail photographs of roof penetrations, vents, and perimeter conditions. Interior photographs document the metal deck substrate, showing rust, corrosion, and water damage patterns.
The roof core samples extracted from three locations (north perimeter, center, and south perimeter) reveal the existing roof assembly composition, which includes membrane layers and substrate board over a metal deck with an underlying ½-inch layer of plywood or particle board that could not be fully retrieved during coring. The photographs collectively demonstrate significant roof deterioration including widespread ponding, material degradation, failed seals, rust on metal components, and evidence of water infiltration. Contractors are instructed to confirm all existing conditions and measurements prior to initiating project activities, indicating this attachment provides reference documentation rather than definitive specifications for the roof replacement work.
View the file
Other files for this federal contract opportunity
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 3:
Photographs
Building 2-3 Roof Replacement North Central Soil Conservation Research Laboratory (NCSCRL) USDA-ARS, Morris, MN
Attachment 3: Photographs
General Notes
1. Photographs shown below were taken in March 2025. The Contactor may use the photographs as a reference / resource in developing their bid / proposal. The Contractor shall confirm all existing conditions and measurements prior to proceeding with any project activities.
PENTHOUSE
BUILDING 2BUILDING 3
BUILDING 8
Photo 2
Photo 1
Photo 3 Photo 4 Photo 5
Building 2-3 Existing Roof Conditions
Photo 6 Photo 7 Photo 8 Photo 9 Photo 10
*Photos of Roof from building interior are shown in Photos 11-11c. Roof cores in Photos 12-12b.
Photo 1
Photo 2
Photo 3
Photo 4
Photo 4a
Photo 4b
Photo 5
Photo 5a
Photo 6 Photo 6a
Photo 7
Photo 7a
Photo 7b
Photo 8 Photo 8b
Photo 8a
Photo 9
Photo 10
Photo 10a
Photo 10b
Photos of Metal Deck from Building 2-3 Interior
Photo 11aPhoto 11 Photo 11cPhoto 11b
Roof Cores
Photo 12 Photo 12a Photo 12b
Roof core taken from center of roof. Roof core taken from north perimeter of roof. Roof core taken from south perimeter of roof.
Note: ½” of plywood/particle board was not able to be retrieved and exists between the last layer (substrate board) and metal deck.