Attachment 3 - FireWorks System Equipment List.pdf

PDF 123 KB Posted

Attached to
FARS PHASE II UPGRADE/FIREWORKS INSTALL
Solicitation number
LT2517250001
Issued by

About this file

This document is an Equipment List for a FireWorks System installation, detailing specific hardware and software components for a federal contract. The equipment list includes 4 UL Listed FireWorks workstations, 2 UL Listed FireWorks servers, 2 LCD touch screen monitors, 6 redundant server client licenses, 1 color graphics software package, 2 wall mount bracket kits, 1 UPS, 2 UPS extenders, 1 server rack, 1 Cisco network switch, and 2 USB keyboards and mice.

Delivery specifications require the contractor to deliver all equipment to Building 1322 at 580 Goodfellow Street, Peterson Space Force Base, between 0800-1600 hours, Monday through Friday. The contractor must coordinate delivery with Material Control at (719) 556-7921 and email the Project Manager, with contact emails provided for Noemi Wikstrom and Mathew Hass from the Space Force.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INSTALL FIRE WORKS SYSTEM

Equipment / Description Qty

FW-UL7W (Workstation) UL Listed FireWorks workstation with 10 LTSC for the Standalone configuration.

FW-UL7S (Server) UL Listed FireWorks Server with Window 10 LTSC for FireWorks networked configuration, redundant and non-redundant

FW-24LCDUL

22" LCD monitor Touch Screen - 22'' 16:9 LCD 115 Vac 1680x1050 resolution capacitive touch screen with integral speakers.

FW-RCZZFP

New Redundant Server Client license. One Hasp PIN Code. Requires one new FW-CGSUL base package, ordered separately.

FW-CGSUL

Color Graphis Software with Common Controls

FW-42LCDHMK1

42'' wall mount bracket kit - single display, horizontal.

SM1500RMXL2UTAA

Uninterruptable Power Supply (UPS) (Does not need sole source)

BP36V42-3U

UPS extender (Does not need sole source)

Comm Server Rack (Does not need sole source) Type: 42U server rack with enclosure

CISCO SWITCH MODEL C9300-24S

Fire Alarm System Network Switch

USB Keyboard (Does not need sole source) 2

USB Mouse (Does not need sole source) 2

1. EQUIPMENT DELIVERY

1.1. The Contractor shall equipment specified in the Equipment List during the hours of 0800 thru 1600 hours, Monday through Friday. Deliver all equipment to Building 1322, 580 Goodfellow Street, Peterson SFB. The contractor shall coordinate delivery with Material Control at (719) 556-7921 and email the Project Manager at noemi.wikstrom.1@spaceforce.mil or Mathew Hass at Mathew.haas.14@spaceforce.mil mailto:noemi.wikstrom.1@spaceforce.mil mailto:Mathew.haas.14@spaceforce.mil