Attachment 2 - FARS Equipment List.pdf
PDF 145 KB Posted
- Attached to
- FARS PHASE II UPGRADE/FIREWORKS INSTALL
- Solicitation number
- LT2517250001
About this file
This file is an Equipment List for a Fire Alarm Reserve System (FARS) Phase II Upgrade, detailing specific networking and power equipment for Peterson Space Force Base. The list includes 8 Cisco Catalyst 9300 24 GE SFP Ports Uplink Switches with 480 Gbps switching capacity, 8 secondary power supplies rated at 715 watts, 350 multi-mode fiber SFP modules, 15 single-mode SFP modules, 10 multi-mode/single-mode fiber transceiver modules, 10 copper SFP modules, and 7 uninterruptable power supplies with 1500VA/900W rating. Additionally, the list includes 200 multi-mode and 10 single-mode fiber patching cables, each 50 feet long. Delivery instructions specify equipment must be delivered to Building 1322 at 580 Goodfellow Street, Peterson SFB, between 0800-1600 hours Monday through Friday, with coordination required through Material Control and notification to specific Space Force project managers.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 3 - FireWorks System Equipment List.pdf | ||
| Sources Sought_FARS PHASE II.docx | DOCX document | |
| Attachment 1 - Performance Work Statement (PWS).pdf | ||
| Attachment 4 - FARS Cyber Requirements.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UPGRADE FIRE ALARM SYSTEM - EQUIPMENT LIST
ITEM CHARACTERISTICS QUANTITY
Catalyst 9300 24 GE SFP Ports Uplink Switch, Cisco C9300-24S-A
24 SFP ports, supporting both 1Gbps and 10Gbps fiber optics.
480 Gbps of switching capacity
715 WAC 80+ platinum Conf 1 Secondary Power Supply Cisco PWR-C1-715WAC- P/2
Rated to provide 715 watts of power AC Input Modular power supply Compatible with Cisco Catalyst 9300 Series switches Supports Power over Ethernet (POE)
100BA SE SFP for GE MMF SFP port Cisco GLC-GE-100FX
Fast Ethernet SFP module Data Rate: 100 Mbps Fiber Type: Multi-Mode Fiber (MMF) Connector Type: LC duplex Wavelength: Operates at a wavelength of 1310 nm Reach: Supports a maximum distance of 2 km (kilometers) over MMF Hot Swappable: Yes, compatible with Cisco devices that have SFP ports Compatibility: Cisco equipment and other devices compliant with MSA (Multi-Source Agreement) for SFPs
100BA SE SFP for GE S Cisco GLC-GE-100FX
Cisco 100 base single mode SFP 15
1000BA SE-LX/LH SFP
transceiver module Cisco GLC-LH SMD
Speed - 1 Gbps (Gigabit Ethernet) Wavelength – 1310nm Media Type – Multimode Fiber (MMF) or Single mode Fiber (SMF) Distance (MMF) - Up to 550 meters (OM3) or 300 meters (OM2) Distance (SMF) - Up to 10 km (6.2 miles) Connector Type – LC (Lucent Connector) Digital Optical Monitoring (DOM)
1000BA SE-T SFP
Cisco GLC-TE
Speed - 1 Gbps (Gigabit Ethernet) Connector Type - RJ45 (Twisted Pair - Cat 5e, Cat 6) Cable Type – Twister Pair (Copper) Maximum Distance (Cat 5e/Cat 6) - Up to 100 meters (328 feet) Digital Optical Monitoring Compatible with networking equipment supporting Gigabit Ethernet over copper TAA Compliant
Uninterruptable Power Supply Trip Lite
SM1500RMXL2UTAA
Rating 1500VA / 900W 120V AC Output
Integrated Surge Protection Minimum 570-joule surge protection rating.
Nominal Input: 120V AC Voltage Range: 83V – 140V Minimum of 8 NEMA 5-15R outlets
Extended Battery Pack Tripp Lite BP36V42-3U
36V DC, 27Ah battery capacity 2U rackmount design Sealed lead-acid batteries Hot Swappable Plug and Play
Fiber Patching Cables Multi Mode LC to ST
50 Feet 200
Fiber Patching Cable Single Mode LC to ST
50 Feet 10
1. E QUIPMENT DELIVERY
1.1. The Contractor shall equipment specified in the Equipment List during the hours of 0800 thru 1600 hours, Monday through Friday. Deliver all equipment to Building 1322, 580 Goodfellow Street, Peterson SFB. The contractor shall coordinate delivery with Material Control at (719) 556-7921 and email the Project Manager at noemi.wikstrom.1@spaceforce.mil or Mathew Hass at Mathew.haas.14@spaceforce.mil mailto:noemi.wikstrom.1@spaceforce.mil mailto:Mathew.haas.14@spaceforce.mil
| UPGRADE FIRE ALARM SYSTEM - EQUIPMENT LIST |