Attachment 3 - Drawings Submittal.PDF
PDF 9 MB Posted
- Attached to
- Outdoor Fitness Facility
- Solicitation number
- FA664822R0002
About this file
This document contains drawings and plans for the construction of an outdoor fitness facility at Homestead Air Reserve Base in Florida. The project will construct a new 2,000 square foot slab on grade and steel frame canopy to accommodate an outdoor fitness area consisting of a 50 foot by 40 foot layout. Drawings show the proposed site plan and location, and include details of existing utilities and infrastructure. The related federal contract opportunity is a solicitation from the Department of the Air Force Reserve Command to complete the outdoor fitness facility. The selected contractor will construct the new slab and canopy in accordance with sustainable design and construction practices as required by executive orders.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LS
LS
LS
LS
LS
LS
Bougainville Blvd.
Tuskegee Blvd.
Ploesti R d.
Elmendorf St.
Campbell Dr.
A m m o
W a y
A m
W y
W e s t o v e r
S t
T u s k e g e
B l v d
F l i g h t l i n
R d
H u s h
H u
H u
H u
H u s h H o u s e R d
Bivouac Rd.
C o r a l
S e a
B l v d
T u r n e r
S t
S a c r a m e n t o
A v e
C a l i f o r n i a
A v e
C a l i f o r n i a
A v e
C o r a l
S e a
B l v d
N e v a d a
A v e
Arizona Ave.
Nevada Ave.
New Mexico Ave.
Reno Ave.
S t
L u l e v a r d
A l a b a
A v e
G e o r g i e
B i k i v d
F l o r i e
Florida Ave.
S o u
C r o l i e
M i s s i s s i p p e
T e x a s A v e
S
N z a i r v d
S
N z a i v d
P i l s
T
A
X
I
W
Y
D
T
A
X
I
W
C
T
A
X
I
W a m y e
T i m
B i k i v d
B i k i v d
D o w
S t.
Bougainville Blvd.
B o u g a i n v i l v d
St. Nazaire Blvd.
S
L u l e v a r d
S a n d i a
A v e
T
A
X
I
W
E
T
A
X
I
W
S p e e d w a y
B l v d
S c h w e i n f u
LS
B u u n
Biggs St.
WATER TAP
WATER TAP
WATER TAP
CAP
CLEAN OUT
CLEAN OUT
6/V
LS
LS
LS
LS
LS
LS
LS
LS
LS
6/V
LS
LS
LS
c o m c o m
A-1
SITE PLAN
OUTDOOR FITNESS FACILITY AT HOMESTEAD AIR RESERVE BASE (HARB)
DESCRIPTION OF WORK:
29050 Coral Sea Blvd, Homestead, FL 33039
SCALE: 3/32"=1'-0"
1 OVERALL SITE PLAN
N
N.T.S.
LOCATION PLAN
N
INDEX OF DRAWINGS
100%
SUBMITTAL
AREA OF WORK
PROJECT #: KYJM 19-9003
SHEET
NUMBER:
REVISIONS:
PR
O
JE
C
T:
O
UT
D O
O R
FI
TN
ES
S
FA
C
IL
ITY
B
UI
LD
IN
G B
-3
A T
HO
M
ES
TE
A D
A
IR
R
ES
ER
V
E
BA
SE
(H
A
RB
100% SUBMITTAL: 09/10/20
A U R E L I O
5735 SW 39TH STREET
M I A M I , F L 3 3 1 5 5 T E L : 3 0 5 . 7 7 6 . 3 2 7 6
DELGADO
ADALBERTO
HO
M
ES
TE
A D
, F L
MEP ENGINEER
STRUCTURAL ENGINEER
archmiamiaad@gmail.com
A R 0 0 1 3 6 3 6
ARCHITECT
C
LI
EN
T:
A D
V A
N C
ED
S
S
PO
B O
X
HU
M A
C A
O , P
.R . 0
PR
O
JE
C
T
: K
YJ
M
9-
C
O
RA
L
SE
A B
O
UL
EV
A
RD
C O
N
TA
C T:
Lu is
A lb er to
R oi g, P
E
C
EO
M O
BI
LE
: 7
-5
-6
EM
A
IL
: a ro ig ad va nc ed ss in c.
co m
C A R L A B, I N C.
ENGINEER AND PLANNERS
CERTIFICATE OF AUTHORIZATION 6419
8730 S.W. 25 ST., MIAMI, FL 33165
TEL: 305 283-3512; FAX: 305 226-0438
Building B-389
ARCHITECT
ADALBERTO A. DELGADO R.A.
5735 SW 39TH STREET
MIAMI, FL 33155
AR 0013636
PH: 305-776-3276
CIVIL ENGINEER
C A R L A B, I N C.
ENGINEER AND PLANNERS
CERTIFICATE OF AUTHORIZATION 6419
8730 S.W. 25 ST., MIAMI, FL 33165
TEL: 305 283-3512; FAX: 305 226-0438
STRUCTURAL ENGINEER
MEP ENGINEER
LIGHTNING PROTECTION
ENGINEER
AutoCAD SHX Text 6"
AutoCAD SHX Text
FS
AutoCAD SHX Text 90%%d BEND
AutoCAD SHX Text
90%%D BEND, 1999/1988
AutoCAD SHX Text
FIRE DELUGE
AutoCAD SHX Text
DELUGE
AutoCAD SHX Text
DELUGE
AutoCAD SHX Text 4"F
AutoCAD SHX Text 6"F
AutoCAD SHX Text 6"F
AutoCAD SHX Text 6"F
AutoCAD SHX Text 2"
AutoCAD SHX Text
AFFF
AutoCAD SHX Text 1"
AutoCAD SHX Text EASEMENT TO COUNTY FOR WATER. 6' TO EACH SIDE OF MAIN AND SOUTH 6' FROM THE METER
AutoCAD SHX Text EASEMENT TO COUNTY FOR WATER. 6' TO EACH SIDE OF MAIN AND SOUTH 6' FROM THE METER
AutoCAD SHX Text 6"
AutoCAD SHX Text 3"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 4"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
6"FW
AutoCAD SHX Text P.I.V.
AutoCAD SHX Text
POSS BURIED 16" VALVE AND CAP
AutoCAD SHX Text 12" D.I.P.
AutoCAD SHX Text P.I.V.
AutoCAD SHX Text 16"
AutoCAD SHX Text 10" D.I.P. 1988
AutoCAD SHX Text 6" D.I.P.
AutoCAD SHX Text 6" D.I.P.
AutoCAD SHX Text P.I.V.
AutoCAD SHX Text
AFFF RETURN
AutoCAD SHX Text
AFFF FEED
AutoCAD SHX Text 2.5"
AutoCAD SHX Text 1.5"
AutoCAD SHX Text 6"
AutoCAD SHX Text 8"
AutoCAD SHX Text 1.5"
AutoCAD SHX Text 4"
AutoCAD SHX Text
10" TEST HEADER TANK RETURN 10" TANK RETURN
AutoCAD SHX Text 10"TANK RETURN 12" SUPPLY MANIFOLD 2x50KGAL AST
AutoCAD SHX Text 12" D.I.P. 1990
AutoCAD SHX Text 6"
AutoCAD SHX Text TWO 12" D.I.P.<1'APART.~3' COVER. LOCATION AND SIZE CONFIRMED NOT LIKE AS-BUILTS ON APR 05 EXCAVATION
AutoCAD SHX Text
AutoCAD SHX Text 6" SINGLE CHECK BP 12"x6" REDUCER
AutoCAD SHX Text
OLD/NEW CONNECTION
AutoCAD SHX Text 2"
AutoCAD SHX Text
LEAK FIXED EARLY 07
AutoCAD SHX Text
LEAK DETECTED 28 SEP 06. EST 5 GPM.
AutoCAD SHX Text
180,000 GAL UNDERGROUND WATER TANK 1944
AutoCAD SHX Text
REPLACEMENT DIP AND TWO COUPLES,2013
AutoCAD SHX Text
TWO 12"90°BENDS ELEV CHANGE
AutoCAD SHX Text
12"X6"REDUCER 6"90°BEND, 6"RISER OUT OFGRADE,6"90°BEND
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIRE DELUGE
AutoCAD SHX Text
16"X10"TEE.1991
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 10"RISER,10"TEE,10"OS&Y, 10x6"REDUCER, 6"GATE VALVE AND FLUSHING FLANGE, MOD 2008
AutoCAD SHX Text 6"
AutoCAD SHX Text 3"
AutoCAD SHX Text
1988/1999 COUPLE
AutoCAD SHX Text
10"TEE
AutoCAD SHX Text
CAPPED 2010
AutoCAD SHX Text
AutoCAD SHX Text
ACOUSTICAL TEST WELL
AutoCAD SHX Text
ACOUSTICAL TEST WELL
AutoCAD SHX Text 8"x8"TEE. PASSES UNDER DOMESTIC GRID
AutoCAD SHX Text 8"P.I.V
AutoCAD SHX Text
8"C-900 DR-14 FIRE SERVICE CONNECT
AutoCAD SHX Text
8"C-900 DR-14. APPROX 2'COVER OVER COMM. SEP 2013.
AutoCAD SHX Text
ACOUSTICAL TEST WELL
AutoCAD SHX Text
8"C-900 DR-14.EVERY OTHER JOINT MECHANICALLY RESTRAINED.TRACER WIRE.SEP 2013.
AutoCAD SHX Text
TWO 8"45°ELBOWS FOR HEIGHT OVER COMM DUCTS,LESS THAN 2'COVER
AutoCAD SHX Text
8"C-900 SLOPES DOWN TO OVER 3'COVER AND PASSES UNDER FIRE HYDRANT BRANCH
AutoCAD SHX Text
ACOUSTICAL TEST WELL
AutoCAD SHX Text
ACOUSTICAL TEST WELL
AutoCAD SHX Text
8"C-900 DR-14.OCT 2013.
AutoCAD SHX Text 8"C-900 DR-14.OCT 2013. AS LITTLE AS 1-FT APART FROM DOMESTIC MAIN AT ACOUSTICAL WELL
AutoCAD SHX Text
8"GATE VALVE
AutoCAD SHX Text
8"C-900 DR-14.EVERY OTHER JOINT MECHANICALLY RESTRAINED.TRACER WIRE.DEC 2013.
AutoCAD SHX Text 8"C-900 DR-14.EVERY OTHER JOINT MECHANICALLY RESTRAINED.TRACER WIRE.4'-8"COVER.JAN 2014.
AutoCAD SHX Text
8"GATE VALVE (TEMP)
AutoCAD SHX Text
16"GATE VALVE.1991
AutoCAD SHX Text
PASSES UNDER STORM SEWER PIPES
AutoCAD SHX Text
PASSES UNDER SANITARY SEWER PIPE.MIN 4'-8"COVER.
AutoCAD SHX Text
TWO 45° ELBOWS FOR ELEVATION CHANGETO PASS OVER U/I PIPE
AutoCAD SHX Text
PASSES UNDER ELECTRICAL
AutoCAD SHX Text 16"x8"REDUCER 2014
AutoCAD SHX Text
NO
AutoCAD SHX Text
PARKING
AutoCAD SHX Text ADDITION OF NEW 2000 S.F. DETACHED 1 STORY OPEN AIR GAZEBO STRUCTURE TO BE USED AS FOR OUTDOOR FITNESS .
AutoCAD SHX Text A-1 COVER SHEET, OVERALL SITE PLAN, INDEX OF DRAWINGSCOVER SHEET, OVERALL SITE PLAN, INDEX OF DRAWINGS
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text
A-3 SITE PLANSITE PLAN
AutoCAD SHX Text A-2 SYMBOL LEGEND, ABBREVIATIONS, GENERAL DATA SYMBOL LEGEND, ABBREVIATIONS, GENERAL DATA
AutoCAD SHX Text
SEE 1/A-3 FOR SITE PLAN
AutoCAD SHX Text
A-4 FLOOR PLAN FLOOR PLAN
AutoCAD SHX Text
A-6 ROOF PLANROOF PLAN
AutoCAD SHX Text
A-7 EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS
AutoCAD SHX Text
A-8 EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS
AutoCAD SHX Text
A-9 BUILDING SECTIONSBUILDING SECTIONS
AutoCAD SHX Text
S001 STRUCTURAL NOTESSTRUCTURAL NOTES
AutoCAD SHX Text
S002 ROOF C&C WIND PRESSURES ROOF C&C WIND PRESSURES
AutoCAD SHX Text S100 FOUNDATION PLAN, COLUMN BLOCKOUT DETAILS, CONTROL JOINT DETAILSFOUNDATION PLAN, COLUMN BLOCKOUT DETAILS, CONTROL JOINT DETAILS
AutoCAD SHX Text
S101 FOOTING DETAILSFOOTING DETAILS
AutoCAD SHX Text
E-1.0 PHOTOMETRIC PLANSPHOTOMETRIC PLANS
AutoCAD SHX Text
E-1.1 LOW VOLTAGE LIGHTING PLANLOW VOLTAGE LIGHTING PLAN
AutoCAD SHX Text
E-1.2 CAT5 WIRING DIAGRAMCAT5 WIRING DIAGRAM
AutoCAD SHX Text
E-1.3 POWER PLAN, PANEL SCHEDULEPOWER PLAN, PANEL SCHEDULE
AutoCAD SHX Text E-2.0 ELECTRICAL RISER DIAGRAM, ELECTRICAL NOTES AND SYMBOLSELECTRICAL RISER DIAGRAM, ELECTRICAL NOTES AND SYMBOLS
AutoCAD SHX Text
LP-1 LIGHTNING PROTECTION PLANLIGHTNING PROTECTION PLAN
AutoCAD SHX Text
C-1 GRADING AND DRAINAGEGRADING AND DRAINAGE
AutoCAD SHX Text
S200 STRUCTURAL ROOF FRAMING PLANSTRUCTURAL ROOF FRAMING PLAN
AutoCAD SHX Text
S200 STRUCTURAL FRAMING DETAILSSTRUCTURAL FRAMING DETAILS
AutoCAD SHX Text
A-5 REFLECTED CEILING PLANREFLECTED CEILING PLAN
AutoCAD SHX Text
A-10 FENCE AND GATE DETAILSFENCE AND GATE DETAILS
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
AutoCAD SHX Text 10/22/2020
A-2
GENERAL DATA
A/C AIR CONDITIONING
ACT ACOUSTICAL TILE
ACT 1 ACOUSTICAL TILE
ADD ADDENDUM/ADHESIVE
ADJ ADJUSTABLE
ADM ADMIN/ADMINISTRATION
A/E ARCHITECT/ENGINEER
AFF ABOVE FINISHED FLOOR
ALUM ALUMINUM
ALT ALTERNATE
ANC ANCHOR (AGE)
ANT ANTENNA
APPROX APPROXIMATE
ARCH ARCHITECT (URAL)
AUTO AUTOMATIC
AVG AVERAGE
BD BOARD
BASE 1 RUBBER
BASE 2 CERAMIC TILE
BASE 3 QUARRY TILE
BEL BELOW
BTW BETWEEN
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BENCH MARK
BO BOTTOM OF
BOTT BOTTOM
BW BOTH WAYS
C/C CENTER TO CENTER
CC CENTER TO CENTER
CAB CABINET
CAM CAMERA
CCTV CLOSED CIRCUIT TELEVISION
CD CONDENSATE DRAIN
CEM CEMENT
CER CERAMIC
CIP CAST-IN-PLACE CONCRETE
CIR CIRCLE
CIRC CIRCUMFERENCE
CJ CONTROL JOINT
CL CHAIN LINK
CLF CHAIN LINK FENCE
CLG CEILING
CLOS CLOSET
CLR CLEAR (ANCE)
CMU CONCRETE MASONRY UNIT
COL COLUMN
COMM COMMUNICATIONS
COMP COMPOSITE
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS OR CONTINUE
CONTR CONTRACT (OR)
CORR CORRIDOR
CP CONTROL POINT
CPT CARPET (ED)
CWSR CHILLED WATER SUPPLY AND RETURN
CUFT CUBIC FEET (FOOT)
CUIN CUBIC INCH CUBIC YARD CUYD
DBL DOUBLE
DECOR DECORATIVE
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER DIA
DIM DIMENSION
DISP DISPENSER
DN DOWN
DO DOOR OPENING
DR DOOR
DS DOWNSPOUT & SCUPPER
DWG DRAWING
E/A EXHAUST AIR
EA EACH
EF EXHAUST FAN
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC (AL)
EWC ELECTRIC WATER COOLER
ELEV ELEVATOR
EMER EMERGENCY
EQ EQUAL
EQUIP EQUIPMENT
EQUIV EQUIVALENT
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EP EPOXY-PAINTED
EXPO EXPOSED TO STRUCTURE
EXT EXTERIOR
FA FIRE ALARM
FCA FIRE CONTROL ASSEMBLY
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FG FIXED GLASS
FHC FIRE HOSE CABINET
FIN FINISH (ED)
FLR FLASHING FLASH FLOOR(ING)
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FOS FACE OF STUDS
FR FRAME (D) (ING)
FT FOOT
FTG FOOTING
FURR FURR (ED) (ING)
FIXT FIXTURE
GA GAGE, GAUGE
GALV GALVANIZED
GC GENERAL CONTRACT (OR)
GL GLASS, GLAZING
GRND GROUND
GWB GYPSUM WALLBOARD
GYP GYPSUM
HB HOSE BIBB
HC HANDICAP
HDR HEADER
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HT HEIGHT
HVAC HEATING/VENTILATING/AIR CONDITIONING
HWH HOT WATER HEATER
INCL INCLUDE (D) (ING)
INS INSULATE (D) (ING)
INT INTERIOR
JT JOINT
KO KNOCKOUT
L LENGTH
LAM LAMINATE
LANDG LANDING
LAV LAVATORY
LBL LABEL
LH LEFT HAND
LL LIVE LOAD
LP LOW POINT
LT LIGHT
LVR LOUVER
MAS MASONRY
MAX MAXIMUM
MECH MECHANIC (AL)
M/E/P MECH/ELEC/PLUMBING
MFR MANUFACTURE (R)
MH METAL HALIDE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MSL MEAN SEA LEVEL
MO MASONRY OPENING
MT MOUNT (ING)
MTD MOUNTED
MTG MEETING
MTL METAL
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O/A OUTSIDE AIR
OC ON CENTER (S)
OD OUTSIDE DIAMETER
OF OVERFLOW
OFS OVERFLOW SCUPPER
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OS OVERFLOW SCUPPER
PC PRECAST
PORC PORCELAIN
PERF PERFORATE (D)
PERP PERPENDICULAR
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLS PLASTIC
PNEU PNEUMATIC
PNL PANEL
PREFAB PREFABRICATED (D)
PREP PREPARATION
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAINT (ED)
PVC POLYVINYL CHLORIDE
PAVE PAVEMENT
PWD PLYWOOD
QTY QUANTITY
RA R/A RETURN AIR
RAD RADIUS
RD ROOF DRAIN
REC RECEPTACLE
RECEPT RECEPTION
REF REFERENCE
REINF REINFORCE (ING)
REQD REQUIRED
REF REFRIGERATOR/FREEZER
RFL REFLECT (ED) (IVE) (OR)
RH RIGHT HAND
RL RAIL (ING)
RLD ROOF LADDER
RM ROOM
RO ROUGH OPENING
RP REFERENCE POINT
RWL RAINWATER LEADER
SA S/A SUPPLY AIR
SAN SANITARY
SCH SCHEDULE
SECT SECTION
SH SHELF
SHT SHEET
SIM SIMILAR
SNT SEALANT
SC SMOOTH CONCRETE
SL SLOPE
SPEC SPECIFICATION
SQ SQUARE
SST STAINLESS STEEL
STL STEEL
STD STANDARD
STO STORAGE
STRUC STRUCTURE
SUPV SUPERVISOR
SUR SURFACE
SUSP SUSPENDED
SYM SYMMETRICAL
SYS SYSTEM
TEL TELEPHONE
TEL TELEPHONE
TEMP TEMPERED
THK THICK (NESS)
TKT TICKET
TO TOP OF
TS TUBE STEEL
TYP TYPICAL
TILE 1 CERAMIC TILE
TILE 2 QUARRY TILE
UGND UNDERGROUND
UNL UNLIMITED
UON UNLESS OTHERWISE NOTED
UR URINAL
VEH VEHICLE
VEN VENEER
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VOL VOLUME
VTR VENT THROUGH ROOF
VCT VINYL COMPOSITION TILE
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDW WINDOW
WM WIRE MESH
WP WATERPROOFING
WT WEIGHT
WWF WELDED WIRE FABRIC
WS WAINSCOT
A6.01
APPROX. AREA
OF DETAIL
DETAIL DWG. NUMBER
SHEET No. ON WHICH DETAIL IS
DRAWN
DETAIL
REFERENCE
SYMBOL
APPROX.
LIMITS OF
SECTION
SECTION DRAWING NUMBER
SHEET No. ON WHICH SECTION IS
DRAWN
WALL/BLDG
SECTION
REFERENCE
SYMBOL
ELEVATION
SYMBOL
CENTER LINE
PROPERTY LINE
ELEVATION MARK
REVISION (NUMBER)
NORTH ARROW
ELEVATION
SHEET No. ON WHICH ELEVATION
IS DRAWN
DOOR
TYPE
WINDOW
TYPE
GENERAL SYMBOLS LEGEND
7/A8.01
W00
INTERIOR ELEVATION
SYMBOL INTERIOR ELEVATION.
DOOR NUMBER. SEE A7.01 FOR DOOR SCHEDULES
WINDOW TYPE. SEE A7.01 FOR WINDOW DETAILS
SHEET
NUMBER:
REVISIONS:
PR
O
JE
C
T:
O
UT
D O
O R
FI
TN
ES
S
FA
C
IL
ITY
B
UI
LD
IN
G B
-3
A T
HO
M
ES
TE
A D
A
IR
R
ES
ER
V
E
BA
SE
(H
A
RB
100% SUBMITTAL: 09/10/20
A U R E L I O
5735 SW 39TH STREET
M I A M I , F L 3 3 1 5 5 T E L : 3 0 5 . 7 7 6 . 3 2 7 6
DELGADO
ADALBERTO
HO
M
ES
TE
A D
, F L
MEP ENGINEER
STRUCTURAL ENGINEER
archmiamiaad@gmail.com
A R 0 0 1 3 6 3 6
ARCHITECT
C
LI
EN
T:
A D
V A
N C
ED
S
S
PO
B O
X
HU
M A
C A
O , P
.R . 0
PR
O
JE
C
T
: K
YJ
M
9-
C
O
RA
L
SE
A B
O
UL
EV
A
RD
C O
N
TA
C T:
Lu is
A lb er to
R oi g, P
E
C
EO
M O
BI
LE
: 7
-5
-6
EM
A
IL
: a ro ig ad va nc ed ss in c.
co m
ABBREVIATIONS
AutoCAD SHX Text
AutoCAD SHX Text A6.50
AutoCAD SHX Text
EL. +1'-0"
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
AutoCAD SHX Text
TYP. UNO
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text C
AutoCAD SHX Text
LSLS
X X
X X
X X
X X
X X
XX
Elmendorf St.
W e s t o v e r
S t
St. Lo Boulevard
BUILDING
BUILDING
A B
A-3
SITE PLAN
SCALE: 1/32"=1'-0"
1 SITE PLAN
N
SHEET
NUMBER:
REVISIONS:
PR
O
JE
C
T:
O
UT
D O
O R
FI
TN
ES
S
FA
C
IL
ITY
B
UI
LD
IN
G B
-3
A T
HO
M
ES
TE
A D
A
IR
R
ES
ER
V
E
BA
SE
(H
A
RB
100% SUBMITTAL: 09/10/20
A U R E L I O
5735 SW 39TH STREET
M I A M I , F L 3 3 1 5 5 T E L : 3 0 5 . 7 7 6 . 3 2 7 6
DELGADO
ADALBERTO
HO
M
ES
TE
A D
, F L
MEP ENGINEER
STRUCTURAL ENGINEER
archmiamiaad@gmail.com
A R 0 0 1 3 6 3 6
ARCHITECT
C
LI
EN
T:
A D
V A
N C
ED
S
S
PO
B O
X
HU
M A
C A
O , P
.R . 0
PR
O
JE
C
T
: K
YJ
M
9-
C
O
RA
L
SE
A B
O
UL
EV
A
RD
C O
N
TA
C T:
Lu is
A lb er to
R oi g, P
E
C
EO
M O
BI
LE
: 7
-5
-6
EM
A
IL
: a ro ig ad va nc ed ss in c.
co m
AutoCAD SHX Text
EXISTING PARKING LOT.
AutoCAD SHX Text
NEW OPEN AIR STRUCTURE. SEE A-4 FOR FLOOR PLAN.
AutoCAD SHX Text
EXISTING BALL FIELD.
AutoCAD SHX Text
NEW FENCE.
AutoCAD SHX Text
EXISTING PAVED TRACK
AutoCAD SHX Text
REFERENCE POINT 01
AutoCAD SHX Text
ROOM # 102
AutoCAD SHX Text
(2) 1-1/2" CONDUIT IN CEILING FOR I/T AND TELECOM. SEE ELEC. DWGS.
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text
UNDERGROUND CONDUIT FOR TELECOM. COORD. W/ OWNER CONSULTANT.
TRENCH BELOW EXISTING RUNNING TRACK.
A-8
A C
A-72
A-8 2
A-7
B
A-8
XXX
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
XXXXXXXXXXXXXXXXXX
X X X
X
A-4
INTERMEDIATEEND
A-4
A-4
FLOOR PLAN
RCP
SCALE: 1/4"=1'-0"
1 FLOOR PLAN
N
SHEET
NUMBER:
REVISIONS:
PR
O
JE
C
T:
O
UT
D O
O R
FI
TN
ES
S
FA
C
IL
ITY
B
UI
LD
IN
G B
-3
A T
HO
M
ES
TE
A D
A
IR
R
ES
ER
V
E
BA
SE
(H
A
RB
100% SUBMITTAL: 09/10/20
A U R E L I O
5735 SW 39TH STREET
M I A M I , F L 3 3 1 5 5 T E L : 3 0 5 . 7 7 6 . 3 2 7 6
DELGADO
ADALBERTO
HO
M
ES
TE
A D
, F L
MEP ENGINEER
STRUCTURAL ENGINEER
archmiamiaad@gmail.com
A R 0 0 1 3 6 3 6
ARCHITECT
C
LI
EN
T:
A D
V A
N C
ED
S
S
PO
B O
X
HU
M A
C A
O , P
.R . 0
PR
O
JE
C
T
: K
YJ
M
9-
C
O
RA
L
SE
A B
O
UL
EV
A
RD
C O
N
TA
C T:
Lu is
A lb er to
R oi g, P
E
C
EO
M O
BI
LE
: 7
-5
-6
EM
A
IL
: a ro ig ad va nc ed ss in c.
co m
RUBBER FLOORING NOTES
A-4
SCALE: 3/4"=1'-0"2 PLAN - TYPICAL COLUMN BASE
DETAIL
SCALE: 3/4"=1'-0"3 SECTION - TYPICAL COLUMN BASE
DETAIL
SCALE: 3"=1'-0"4 ELEVATION - FLOOR MOUNTED SIT UP BAR
DETAIL
SCALE: 3"=1'-0"5 SECTION - FLOOR MOUNTED SIT UP BAR
DETAIL
AutoCAD SHX Text
EDGE OF CONC. SLAB.
AutoCAD SHX Text
RUBBERIZED FLOORING ON CONC. SLAB
AutoCAD SHX Text
STL. COLUMNS. SEE STRUCT. DWGS. TYP.
AutoCAD SHX Text
3' HIGH SPLIT FACE CMU ENCASEMENT. TYP.
AutoCAD SHX Text
R.W.L. AND CONC. SPLASH BLOCK. TYP.
AutoCAD SHX Text
CLEAR BETWEEN COLUMNS.
AutoCAD SHX Text
CLEAR BETWEEN COLUMNS.
AutoCAD SHX Text
EXISTING PARKING LOT
AutoCAD SHX Text
7' HIGH STL. PICKET FENCE. SEE 1/A-10.
AutoCAD SHX Text
(2)-3'X6'-8" GATES. SEE 3/A-10.
AutoCAD SHX Text
3'X6'-8" GATE. SEE 2/A-10.
AutoCAD SHX Text
7' HIGH STL. PICKET FENCE. SEE 1/A-10.
AutoCAD SHX Text V.I.F.
AutoCAD SHX Text
5"CONC. WALK.
AutoCAD SHX Text
3'X6'-8" GATE. SEE 2/A-10.
AutoCAD SHX Text
FLR. MOUNTED SIT-UP BAR. SEE 4/A-4. TYP.
AutoCAD SHX Text
4"X4"X16" SOLID SPLIT FACE CMU CAP.
AutoCAD SHX Text
4"X8"X16" SOLID SPLIT FACE CMU CAP.
AutoCAD SHX Text
CONT. SEALANT.
AutoCAD SHX Text
PAINTED STL. COLUMN. SEE STRUCT. DWGS..
AutoCAD SHX Text
SHEET MTL ANCHOR ON ALTERNATE COURSES. 1 PER FACE OF COLUMN.
AutoCAD SHX Text
4"X4"X16" SOLID SPLIT FACE CMU CAP.
AutoCAD SHX Text
PAINT COLUMN W/ BITUMINOUS PAINT AT VENEER FACING.
AutoCAD SHX Text
1/2" POURED RUBBER FLOOR.
AutoCAD SHX Text
2" GALV. PIPEW/ THREADED ENDS.
AutoCAD SHX Text
GALV.PIPE FITTINGS. TYP..
AutoCAD SHX Text
(4) 3/8"X3" CONC. ANCHORS.
AutoCAD SHX Text
2" GALV. PIPE W/THREADED ENDS.
AutoCAD SHX Text
GALV. PIPE FITTINGS. TYP.
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text RUBBER FLOORING TO BE 1/2" WET POURED EPDM (ETHYLENE PROPYLENE DIENE MONOMER) RUBBER AND POLYURETHANE BINDER FLOORING.
SUBMIT (2) 9"X9" SAMPLES FOR APPROVAL.
A-8
CB
A-8
FRONTSECTION
A-5
A-5
REFLECTED
CEILING PLAN
SHEET
NUMBER:
REVISIONS:
PR
O
JE
C
T:
O
UT
D O
O R
FI
TN
ES
S
FA
C
IL
ITY
B
UI
LD
IN
G B
-3
A T
HO
M
ES
TE
A D
A
IR
R
ES
ER
V
E
BA
SE
(H
A
RB
100% SUBMITTAL: 09/10/20
A U R E L I O
5735 SW 39TH STREET
M I A M I , F L 3 3 1 5 5 T E L : 3 0 5 . 7 7 6 . 3 2 7 6
DELGADO
ADALBERTO
HO
M
ES
TE
A D
, F L
MEP ENGINEER
STRUCTURAL ENGINEER
archmiamiaad@gmail.com
A R 0 0 1 3 6 3 6
ARCHITECT
C
LI
EN
T:
A D
V A
N C
ED
S
S
PO
B O
X
HU
M A
C A
O , P
.R . 0
PR
O
JE
C
T
: K
YJ
M
9-
C
O
RA
L
SE
A B
O
UL
EV
A
RD
C O
N
TA
C T:
Lu is
A lb er to
R oi g, P
E
C
EO
M O
BI
LE
: 7
-5
-6
EM
A
IL
: a ro ig ad va nc ed ss in c.
co m
C A R L A B, I N C.
ENGINEER AND PLANNERS
CERTIFICATE OF AUTHORIZATION 6419
8730 S.W. 25 ST., MIAMI, FL 33165
TEL: 305 283-3512; FAX: 305 226-0438
SCALE: 1/4"=1'-0"
1 REFLECTED CEILING PLAN
N
SCALE: 3/4"=1'-0"2 ELEVATION - FAN MOUNTING
DETAIL
SCALE: 3"=1'-0"3 GUY WIRE ANCHOR
DETAIL
SCALE: 3/4"=1'-0"4 ELEVATION - ROPE CLIMBING SUPPORT
DETAIL
CEILING FAN NOTES
AutoCAD SHX Text
HIGH BAY LED LIGHT FIXTURES. TYP.
AutoCAD SHX Text
CONT. MTL. GUTTER.
AutoCAD SHX Text
5" R.W.L.TYP. OF (4).
AutoCAD SHX Text
ROPE HOOKS. TYP. OF (2)
AutoCAD SHX Text
HIGH DENSITY POLYETHYLENE BIRD NETTING ANCHORED TO B.O. PURLINS.
AutoCAD SHX Text
STL. BEAM. SEE STRUCT. DWGS. TYP.
AutoCAD SHX Text O.H.
AutoCAD SHX Text O.H.
AutoCAD SHX Text O.H.
AutoCAD SHX Text O.H.
AutoCAD SHX Text
HVLS FAN. TYP. OF (4). SEE 2/A-5 FOR MOUNTING DETAIL.
AutoCAD SHX Text
HIGH BAY LED LIGHT FIXTURES. TYP.
AutoCAD SHX Text
PURLINS ABOVE. SEE STRUCTURAL DWGS.
AutoCAD SHX Text
EXTERIOR LIGHTING.
AutoCAD SHX Text
OFFSET MOUNTING BRACKET.
AutoCAD SHX Text
EXTENSION TUBE.
AutoCAD SHX Text
GUY WIRES AT 45 .
AutoCAD SHX Text
GUY WIRE ANCHOR. SEE 3/A-5.
AutoCAD SHX Text
LOWER MOUNTING BRACKET.
AutoCAD SHX Text
SAFETY CABLE.
AutoCAD SHX Text
ALIGN B.O. FAN W/ B.O. BEAM BEYOND.
AutoCAD SHX Text
STL RAFTER. SEE STRUCTURAL DWGS.
AutoCAD SHX Text
BIRD NETTING.
AutoCAD SHX Text
WELD ANCHOR. TO RAFTER.
AutoCAD SHX Text
STL RAFTER. SEE STRUCTURAL DWGS.
AutoCAD SHX Text
1" RADIUS.
AutoCAD SHX Text
GUY WIRE ANCHOR FROM 3"X2"X1/4" STL. ANGLE.
AutoCAD SHX Text
3/4" HOLE.SMOOTH EDGES.
AutoCAD SHX Text
S.S. BIRD SPIKES ON TOP OF ANGLE..
AutoCAD SHX Text
2"X4"X1/4" STL. ANGLE.
AutoCAD SHX Text
15'-0" TO FIN. FLOOR.
AutoCAD SHX Text
2-1/2"X2-1/2"X1/4" STL. TUBE .
AutoCAD SHX Text
30"X6"X1/8" STL. STIFFENER PLATE. .
AutoCAD SHX Text
BIRD NETTING SUPPORT.
AutoCAD SHX Text
1-1/2"X1-1/2"X1/4" X 4" LONG STL. ANGLE.
AutoCAD SHX Text
3/4" THRU BOLT.
AutoCAD SHX Text
SPACER (SUPPORT FOR ROPE RIGGING).
AutoCAD SHX Text
BIRD NETTING.
AutoCAD SHX Text
S.S. BIRD SPIKES ON TOP OF ANGLE.
AutoCAD SHX Text
2"X4"X1/4" STL. ANGLE.
AutoCAD SHX Text
2-1/2"X2-1/2"X1/4" STL. TUBE.
AutoCAD SHX Text
3/4" THRU BOLT.
AutoCAD SHX Text 1.
AutoCAD SHX Text
CEILING FAN BASIS OF DESIGN:
AutoCAD SHX Text
MANUFACTURER: BIG ASS FAN.BIG ASS FAN.
AutoCAD SHX Text
MODEL: POWERFOIL D.POWERFOIL D.
SIZE: 8'-0" DIAMETER8'-0" DIAMETER
A B
A-62
A-7
A-7 2
A-6
A-8
A-6
ROOF PLAN
SCALE: 1/4"=1'-0"
1 ROOF PLAN
N
SHEET
NUMBER:
REVISIONS:
PR
O
JE
C
T:
O
UT
D O
O R
FI
TN
ES
S
FA
C
IL
ITY
B
UI
LD
IN
G B
-3
A T
HO
M
ES
TE
A D
A
IR
R
ES
ER
V
E
BA
SE
(H
A
RB
100% SUBMITTAL: 09/10/20
A U R E L I O
5735 SW 39TH STREET
M I A M I , F L 3 3 1 5 5 T E L : 3 0 5 . 7 7 6 . 3 2 7 6
DELGADO
ADALBERTO
HO
M
ES
TE
A D
, F L
MEP ENGINEER
STRUCTURAL ENGINEER
archmiamiaad@gmail.com
A R 0 0 1 3 6 3 6
ARCHITECT
C
LI
EN
T:
A D
V A
N C
ED
S
S
PO
B O
X
HU
M A
C A
O , P
.R . 0
PR
O
JE
C
T
: K
YJ
M
9-
C
O
RA
L
SE
A B
O
UL
EV
A
RD
C O
N
TA
C T:
Lu is
A lb er to
R oi g, P
E
C
EO
M O
BI
LE
: 7
-5
-6
EM
A
IL
: a ro ig ad va nc ed ss in c.
co m
ROOFING NOTES
SCALE: 6"=1'-0"3 ROOF EAVE / GUTTER
DETAIL
AutoCAD SHX Text
CONT. MTL. GUTTER.
AutoCAD SHX Text
INSULATED (R-15 MIN.) MTL. PANEL ROOFING SYSTEM.
AutoCAD SHX Text 5" R.W.L.
AutoCAD SHX Text 5" R.W.L.
AutoCAD SHX Text 5" R.W.L.
AutoCAD SHX Text 5" R.W.L.
AutoCAD SHX Text GUTTER BRACKET: MIN. 1" WIDE ROLLED GUTTER METAL, MIN. 16-GA GALVANIZED, OR " 18" ALUMINUM (MATCH GUTTER MATERIAL). LOCATE GUTTER BRACKETS 6' O.C. AT EVERY OTHER GUTTER STRAP AND AT FREE ENDS WITHOUT DOWNSPOUTS.
AutoCAD SHX Text
POP RIVETS OR SHEET MTL SCREWS TO FASTEN GUTTER TO BRACKET AND STRAP
AutoCAD SHX Text
GUTTER RIM.
AutoCAD SHX Text
1" WIDE ROLLED GUTTER STRAP POP RIVETED TO GUTTER 36" O.C. MAX.
AutoCAD SHX Text FASTEN GUTTER BRACKETS UNDER GUTTER, SSMR: #10 FLATHEAD MTL. SCREWS THRU FASCIA AND INTO STRUCTURAL PURLIN. CAULK OVER HEADS.
AutoCAD SHX Text
FORMED ALUM. FLASHING AND EAVE BY ROOFING MANUF.
AutoCAD SHX Text
PURLIN. SEE STRUCTURAL DWGS.
AutoCAD SHX Text #12 X 1.75 FLATHEAD MTL. SCREWS THRU FASCIA AND INTO STRUCTURAL PURLIN. (2) @ EACH BRACKET. CAULK OVER HEADS.
AutoCAD SHX Text
INSULATED (R-15 MIN.) MTL. ROOF PANEL SYSTEM.
AutoCAD SHX Text
GUTTER: .032 GAUGE KYNAR PAINT PRE-FIN. GUTTER. COLOR TO BE APPROVED BY OWNER.
AutoCAD SHX Text LEADER: 3"X4" .032 GAUGE ALUMINUM KYNAR PAINT PRE-FIN. COLOR TO BE APPROVED BY OWNER.
AutoCAD SHX Text 1.
AutoCAD SHX Text
ROOFING SYSTEM BASIS OF DESIGN:
AutoCAD SHX Text
MANUFACTURER: GREEN SPAN PROFILESGREEN SPAN PROFILES
AutoCAD SHX Text
MODEL: IRP SERIES METAL ROOF PANEL SYSTEMIRP SERIES METAL ROOF PANEL SYSTEM
NOA: 19-0417.0419-0417.04
AC B
A-8
A-7
EXTERIOR
ELEVATIONS
SCALE: 1/4"=1'-0"1
NORTH ELEVATION
SCALE: 1/4"=1'-0"2
EAST ELEVATION SHEET
NUMBER:
REVISIONS:
PR
O
JE
C
T:
O
UT
D O
O R
FI
TN
ES
S
FA
C
IL
ITY
B
UI
LD
IN
G B
-3
A T
HO
M
ES
TE
A D
A
IR
R
ES
ER
V
E
BA
SE
(H
A
RB
100% SUBMITTAL: 09/10/20
A U R E L I O
5735 SW 39TH STREET
M I A M I , F L 3 3 1 5 5 T E L : 3 0 5 . 7 7 6 . 3 2 7 6
DELGADO
ADALBERTO
HO
M
ES
TE
A D
, F L
MEP ENGINEER
STRUCTURAL ENGINEER
archmiamiaad@gmail.com
A R 0 0 1 3 6 3 6
ARCHITECT
C
LI
EN
T:
A D
V A
N C
ED
S
S
PO
B O
X
HU
M A
C A
O , P
.R . 0
PR
O
JE
C
T
: K
YJ
M
9-
C
O
RA
L
SE
A B
O
UL
EV
A
RD
C O
N
TA
C T:
Lu is
A lb er to
R oi g, P
E
C
EO
M O
BI
LE
: 7
-5
-6
EM
A
IL
: a ro ig ad va nc ed ss in c.
co m
AutoCAD SHX Text
2" INSULATED METAL ROOFING SYSTEM ON Z-PURLINS.
AutoCAD SHX Text
STL COLUMN SEE STUCT. DWGS.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STL BEAM, SEE STRUCT. DWGS.
AutoCAD SHX Text
12' REQD.
AutoCAD SHX Text
CONT. PAINTED MTL. GUTTER.
AutoCAD SHX Text
SPLIT FACE CMU BASE.
AutoCAD SHX Text
R.W.L. AND CONC. SPLASH BLOCK. TYP.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STL COLUMN SEE STUCT. DWGS.
AutoCAD SHX Text
SPLIT FACE CMU BASE.
AutoCAD SHX Text
STL BEAM, SEE STRUCT. DWGS.
AutoCAD SHX Text
2" INSULATED METAL ROOFING SYSTEM ON Z-PURLINS.
CONT. PAINTED MTL. GUTTER.
A-9
A C
B
1 2 3 4
A-9
A-8
EXTERIOR
ELEVATIONS
SCALE: 1/4"=1'-0"1
SOUTH ELEVATION
SCALE: 1/4"=1'-0"2
WEST ELEVATION SHEET
NUMBER:
REVISIONS:
PR
O
JE
C
T:
O
UT
D O
O R
FI
TN
ES
S
FA
C
IL
ITY
B
UI
LD
IN
G B
-3
A T
HO
M
ES
TE
A D
A
IR
R
ES
ER
V
E
BA
SE
(H
A
RB
100% SUBMITTAL: 09/10/20
A U R E L I O
5735 SW 39TH STREET
M I A M I , F L 3 3 1 5 5 T E L : 3 0 5 . 7 7 6 . 3 2 7 6
DELGADO
ADALBERTO
HO
M
ES
TE
A D
, F L
MEP ENGINEER
STRUCTURAL ENGINEER
archmiamiaad@gmail.com
A R 0 0 1 3 6 3 6
ARCHITECT
C
LI
EN
T:
A D
V A
N C
ED
S
S
PO
B O
X
HU
M A
C A
O , P
.R . 0
PR
O
JE
C
T
: K
YJ
M
9-
C
O
RA
L
SE
A B
O
UL
EV
A
RD
C O
N
TA
C T:
Lu is
A lb er to
R oi g, P
E
C
EO
M O
BI
LE
: 7
-5
-6
EM
A
IL
: a ro ig ad va nc ed ss in c.
co m
AutoCAD SHX Text
2" INSULATED METAL ROOFING SYSTEM ON Z-PURLINS.
AutoCAD SHX Text
STL COLUMN SEE STUCT. DWGS.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STL BEAM, SEE STRUCT. DWGS.
AutoCAD SHX Text
12' REQD.
AutoCAD SHX Text
CONT. PAINTED MTL. GUTTER.
AutoCAD SHX Text
SPLIT FACE CMU BASE.
AutoCAD SHX Text
R.W.L. AND CONC. SPLASH BLOCK. TYP.
AutoCAD SHX Text
SIT-UP BAR SEE 4/A-4
AutoCAD SHX Text
STL COLUMN SEE STUCT. DWGS.
AutoCAD SHX Text
SPLIT FACE CMU BASE.
AutoCAD SHX Text
STL BEAM, SEE STRUCT. DWGS.
AutoCAD SHX Text
CONT. PAINTED MTL. GUTTER.
AutoCAD SHX Text
AutoCAD SHX Text
2" INSULATED METAL ROOFING SYSTEM ON Z-PURLINS.
A CB
A-5
T.O. CONC. SLAB
EL. + 0'-0" (+ 8.7' NGVD)
B.O. TIE BEAM
EL. + 12'-2"
A-6
A-9
BUILDING
SECTIONS
SCALE: 1/4"=1'-0"1 TRAVERSE
BUILDING SECTION
SHEET
NUMBER:
REVISIONS:
PR
O
JE
C
T:
O
UT
D O
O R
FI
TN
ES
S
FA
C
IL
ITY
B
UI
LD
IN
G B
-3
A T
HO
M
ES
TE
A D
A
IR
R
ES
ER
V
E
BA
SE
(H
A
RB
100% SUBMITTAL: 09/10/20
A U R E L I O
5735 SW 39TH STREET
M I A M I , F L 3 3 1 5 5 T E L : 3 0 5 . 7 7 6 . 3 2 7 6
DELGADO
ADALBERTO
HO
M
ES
TE
A D
, F L
MEP ENGINEER
STRUCTURAL ENGINEER
archmiamiaad@gmail.com
A R 0 0 1 3 6 3 6
ARCHITECT
C
LI
EN
T:
A D
V A
N C
ED
S
S
PO
B O
X
HU
M A
C A
O , P
.R . 0
PR
O
JE
C
T
: K
YJ
M
9-
C
O
RA
L
SE
A B
O
UL
EV
A
RD
C O
N
TA
C T:
Lu is
A lb er to
R oi g, P
E
C
EO
M O
BI
LE
: 7
-5
-6
EM
A
IL
: a ro ig ad va nc ed ss in c.
co m
C A R L A B, I N C.
ENGINEER AND PLANNERS
CERTIFICATE OF AUTHORIZATION 6419
8730 S.W. 25 ST., MIAMI, FL 33165
TEL: 305 283-3512; FAX: 305 226-0438
SCALE: 1/4"=1'-0"2 LONGITUDINAL
BUILDING SECTION
SCALE: 3/4"=1'-0"3
TYPICAL WALL SECTION
AutoCAD SHX Text
CLEAR BETWEEN COLUMNS
AutoCAD SHX Text
STL COLUMN. SEE STRUCT. DWGS
AutoCAD SHX Text
STL BEAM. SEE STRUCT. DWGS.
AutoCAD SHX Text
SPLIT FACE CMU.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STL BEAM. SEE STRUCT. DWGS.
AutoCAD SHX Text
RUBBER FLOORING
AutoCAD SHX Text
SLOPE 1"
AutoCAD SHX Text
SLOPE 1"
AutoCAD SHX Text
CONT. GUTTER.
AutoCAD SHX Text
O.H. TYP.
AutoCAD SHX Text
INSULATED ROOF PANELS(R-15 MIN.) ON Z-PURLINS.
AutoCAD SHX Text
HI OUTPUT LED LIGHT FIXTURE TYP.
AutoCAD SHX Text
HI OUTPUT LED LIGHT FIXTURE TYP.
AutoCAD SHX Text
O.H. TYP.
AutoCAD SHX Text
STL COLUMN. SEE STRUCT. DWGS
AutoCAD SHX Text
STL BEAM. SEE STRUCT. DWGS.
AutoCAD SHX Text
12' REQD.
AutoCAD SHX Text
SPLIT FACE CMU.
AutoCAD SHX Text
INSULATED ROOF PANELS(R-15 MIN.) ON Z-PURLINS.
AutoCAD SHX Text
CONT. GUTTER.
AutoCAD SHX Text
HIGH VOLUME LOW VELOCITY (HVLV) FAN. SEE 2/A-5.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ROPE CLIMBING SUPPORT TYP. OF 2.
AutoCAD SHX Text
INSULATED MTL. ROOF PANEL SYSTEM.
AutoCAD SHX Text
CONT. PAINTED ALUMINUM GUTTER.
AutoCAD SHX Text
STEEL PURLINS. SEE STRUCT. DWGS. TYP.
AutoCAD SHX Text
STEEL TUBE W/ PAINT FINISH. SEE STRUCT. DWGS. TYP.
AutoCAD SHX Text
STEEL BEAM W/ PAINT FINISH. SEE STRUCT. DWGS. TYP.
AutoCAD SHX Text
STEEL COLUMN W/ PAINT FINISH. SEE STRUCT. DWGS. TYP.
AutoCAD SHX Text
4" SPLIT FACE CMU FACING.
PRECAST CONC. SPLASH BLOCK.
A-10
FENCE DETAILS
SCALE: 3/4"=1'-0"
TYPICAL FENCE PANEL
ELEVATION DETAIL
SHEET
NUMBER:
REVISIONS:
PR
O
JE
C
T:
O
UT
D O
O R
FI
TN
ES
S
FA
C
IL
ITY
B
UI
LD
IN
G B
-3
A T
HO
M
ES
TE
A D
A
IR
R
ES
ER
V
E
BA
SE
(H
A
RB
100% SUBMITTAL: 09/10/20
A U R E L I O
5735 SW 39TH STREET
M I A M I , F L 3 3 1 5 5 T E L : 3 0 5 . 7 7 6 . 3 2 7 6
DELGADO
ADALBERTO
HO
M
ES
TE
A D
, F L
MEP ENGINEER
STRUCTURAL ENGINEER
archmiamiaad@gmail.com
A R 0 0 1 3 6 3 6
ARCHITECT
C
LI
EN
T:
A D
V A
N C
ED
S
S
PO
B O
X
HU
M A
C A
O , P
.R . 0
PR
O
JE
C
T
: K
YJ
M
9-
C
O
RA
L
SE
A B
O
UL
EV
A
RD
C O
N
TA
C T:
Lu is
A lb er to
R oi g, P
E
C
EO
M O
BI
LE
: 7
-5
-6
EM
A
IL
: a ro ig ad va nc ed ss in c.
co m
FENCE NOTES
SCALE: 3/4"=1'-0"
TYPICAL 3' GATE
ELEVATION DETAIL
SCALE: 3/4"=1'-0"
TYPICAL PAIR - 3' GATES
ELEVATION DETAIL
AutoCAD SHX Text
3/4"X3/4" 14 GA. PICKETS. TYP.
AutoCAD SHX Text
18" X 40" MIN.CONC. FTG. TYP.
AutoCAD SHX Text
1-1/2" BOTTOM RAIL. TYP.
AutoCAD SHX Text
1-1/2" DOUBLE TOP RAIL. TYP.
AutoCAD SHX Text
3"X3" 12 GA. POSTS. TYP.
AutoCAD SHX Text
FLAT CAP. TYP.
AutoCAD SHX Text
MAX. (NOM.)
AutoCAD SHX Text
SLOPE AWAY FROM COLUMN 1/4" TYP.
AutoCAD SHX Text
#3 TIES @ 12" O.C.
AutoCAD SHX Text
(4) #5 VERT.
AutoCAD SHX Text
CONT. SEALANT AROUND POST. TYP.
AutoCAD SHX Text
18" X 40" DEEP MIN.CONC. FTG. TYP.
AutoCAD SHX Text 14 GA. STL. KICK PLATE BOTH SIDES TO FACE OF 2"X2" FRAME. GRIND EDGES SMOOTH. PAINTED FIN. TO MATCH GATE.
AutoCAD SHX Text
3"X3" 12 GA. POSTS. TYP.
AutoCAD SHX Text
3 HEAVY DUTY HINGES PER GATE. TYP.
AutoCAD SHX Text 14 GA. STL. PLATE ON INSIDE FACE TO MOUNT PANIC HARDWARE EXTEND TO FACE OF 2"X2" FRAME. GRIND EDGES SMOOTH. PAINTED FIN. TO MATCH GATE.
AutoCAD SHX Text
SLOPE AWAY FROM COLUMN 1/4" TO CONC. SLAB TYP.
AutoCAD SHX Text
CONT. SEALANT AROUND POST. TYP.
AutoCAD SHX Text
EXPANSION JOINT FILLER. TYP.
AutoCAD SHX Text
#3 TIES @ 12" O.C.
AutoCAD SHX Text
(4) #5 VERT.
AutoCAD SHX Text EXPANDED MTL. INFILL. FLATTENED, GALVANIZED STEEL, HOT DIPPED, 3/4" NO. 16 FLATTENED, 76% OPEN AREA.
AutoCAD SHX Text
PROVIDE 24" EXPANDED MTL. INFILL PANELS EACH SIDE OF GATE. TYP.
AutoCAD SHX Text
SELF LATCHING PANIC HARDWARE C/L MTD. 44" ABOVE T.O. FIN. FLR.
AutoCAD SHX Text
2"X2"X1/4" TOP RAIL WELDED TO POSTS.
AutoCAD SHX Text
2"X2"X1/4" TOP RAIL WELDED TO POSTS.
AutoCAD SHX Text
CLOSER.
AutoCAD SHX Text
2"X2"X1/4" TOP RAIL WELDED TO POSTS.
AutoCAD SHX Text
CLOSER.
AutoCAD SHX Text
5/8" S.S. CANEBOLT ON INSIDE OF EACH GATE.
AutoCAD SHX Text
18" X 40" DEEP MIN.CONC. FTG. TYP.
AutoCAD SHX Text 14 GA. STL. KICK PLATE BOTH SIDES TO FACE OF 2"X2" FRAME. GRIND EDGES SMOOTH. PAINTED FIN. TO MATCH GATE.
AutoCAD SHX Text
3"X3" 12 GA. POSTS. TYP.
AutoCAD SHX Text
2"X2"X1/4" TOP RAIL WELDED TO POSTS.
AutoCAD SHX Text
3 HEAVY DUTY HINGES PER GATE. TYP.
AutoCAD SHX Text 14 GA. STL. PLATE ON INSIDE FACE TO MOUNT PANIC HARDWARE EXTEND TO FACE OF 2"X2" FRAME. GRIND EDGES SMOOTH. PAINTED FIN. TO MATCH GATE.
AutoCAD SHX Text
SLOPE AWAY FROM COLUMN 1/4" TO CONC. SLAB TYP.
AutoCAD SHX Text
CONT. SEALANT AROUND POST. TYP.
AutoCAD SHX Text
EXPANSION JOINT FILLER. TYP.
AutoCAD SHX Text
#3 TIES @ 12" O.C.
AutoCAD SHX Text
(4) #5 VERT.
AutoCAD SHX Text EXPANDED MTL. INFILL. FLATTENED, GALVANIZED STEEL, HOT DIPPED, 3/4" NO. 16 FLATTENED, 76% OPEN AREA.
AutoCAD SHX Text
PANIC HARDWARE C/L MTD. 44" ABOVE T.O. FIN. FLR.
AutoCAD SHX Text
PROVIDE 24" EXPANDED MTL. INFILL PANELS EACH SIDE OF GATE. TYP.
AutoCAD SHX Text
2"X2"X1/4" TOP RAIL WELDED TO POSTS.
AutoCAD SHX Text
CLOSER.
AutoCAD SHX Text BASIS OF DESIGN: AMERISTAR PERIMETER SECURITY USA INC. MONTAGE COMMERCIAL - COMMERCIAL STEEL ORNAMENTAL FENCE SYSTEM - FUSION WELDED AND RACKABLE OR APPROVED EQUAL BY MASTER HALCO / JERIITH / LYNCHBURG FENCE & RAILING.
AutoCAD SHX Text 1.
AutoCAD SHX Text PAINT FINISH: GALVANIZED STEEL FRAMEWORK W/ MULTI-STAGE PRE-TREATMENT/WASH (WITH ZINC PHOSPHATE), FOLLOWED BY A DUPLEX CATHODIC ELECTROCOAT SYSTEM CONSISTING OF AN EPOXY PRIMER, AND AN ACRYLIC TOPCOAT ALL SIDES. COLOR: BLACK.
AutoCAD SHX Text 2.
AutoCAD SHX Text
HARDWARE:
AutoCAD SHX Text 6.
AutoCAD SHX Text ADA COMPLIANT LOCKSET BY BEST LOCK CORP OF FALCON LOCK. LEVER HANDLE FOR ALL DOORS. PROVIDE RIM CYLINDERS, MORTISE CYLINDERS, AND KNOBS OF BORED LOCKSETS WITH INTERCHANGEABLE CORES USING SEVEN PIN TUMBLERS REMOVABLE BY SPECIAL CONTROL KEYS AND CYLINDERS FROM PRODUCTS OF ONE MANUFACTURER, AND PROVIDE CORES FROM THE PRODUCTS OF BEST LOCK CORP OF FALCON LOCK.
AutoCAD SHX Text
SINGLE GATE:
AutoCAD SHX Text
5 LBS. MAX. OPERATING FORCE.
AutoCAD SHX Text
VON DUPRIN EXIT HARDWARE MODEL 98/9952.
AutoCAD SHX Text
(3) HEAVY DUTY HINGES PER GATE.
AutoCAD SHX Text
ALLEGION 4040 SERIES CLOSER.
AutoCAD SHX Text ADA COMPLIANT LOCKSET BY BEST LOCK CORP OF FALCON LOCK. LEVER HANDLE FOR ALL DOORS. PROVIDE RIM CYLINDERS, MORTISE CYLINDERS, AND KNOBS OF BORED LOCKSETS WITH INTERCHANGEABLE CORES USING SEVEN PIN TUMBLERS REMOVABLE BY SPECIAL CONTROL KEYS AND CYLINDERS FROM PRODUCTS OF ONE MANUFACTURER, AND PROVIDE CORES FROM THE PRODUCTS OF BEST LOCK CORP OF FALCON LOCK.
AutoCAD SHX Text
DOUBLE GATE:
AutoCAD SHX Text
5 LBS. MAX. OPERATING FORCE.
AutoCAD SHX Text
(3) HEAVY DUTY HINGES PER GATE.
AutoCAD SHX Text
ALLEGION 4040 SERIES CLOSER.
AutoCAD SHX Text PAINT FINISH: GALVANIZED STEEL FRAMEWORK W/ MULTI-STAGE PRE-TREATMENT/WASH (WITH ZINC PHOSPHATE), FOLLOWED BY A DUPLEX CATHODIC ELECTROCOAT SYSTEM CONSISTING OF AN EPOXY PRIMER, AND AN ACRYLIC TOPCOAT ALL SIDES. COLOR: BLACK.
AutoCAD SHX Text 3.
AutoCAD SHX Text PROVIDE CADR READERS AT ALL GATES. COORDINATE W/ SMARTNET REPRESENTATIVE POINT OF CONTACT IS MR. JASON (732) 476-8706.
AutoCAD SHX Text 4.
AutoCAD SHX Text
GRIND ALL SHARP EDGES INCLUDING BOLTS, SCREWS, AND FACE PLATES.
5.
O
UT
D O
O R
FI
TN
ES
S
FA
C
IL
ITY
B
UI
LD
IN
G B
-3
A T
HO
M
ES
TE
A D
A
IR
R
ES
ER
V
E
BA
SE
(H
A
RB
ADALBERTO
HO
M
ES
TE
A D
, F L
A D
V A
N C
ED
S
S
PO
B O
X
HU
M A
C A
O , P
.R . 0
PR
O
JE
C
T
: K
YJ
M
9-
C
O
RA
L
SE
A B
O
UL
EV
A
RD
Lu is
A lb er to
R oi g, P
E
C
EO
M O
BI
LE
: 7
-5
-6
EM
A
IL
: a ro ig ad va nc ed ss in c.
co m gg g
SITE
N.T.S.
A. CODES & STANDARS:
B. DESIGN CRITERIA:
STRUCTURAL NOTES
D. CONCRETE
C. GENERAL:
B.1 GEOTECHNICAL INFORMATION:
E. REINFORCING STEEL:
F. MASONRY:
G. CONCRETE SLAB ON GRADE:
H. POST-INSTALLED ANCHORS
I. MECHANICAL ANCHORS
NOTES:
TENSION DEVELOPMENT & LAP SPLICE LENGTH SCHEDULES
J. SCREW ANCHORS
K. ADHESIVE ANCHORS
N. SHEAR STUD CONNECTORS
M. WELDING
L. STRUCTURAL STEEL
SHEET
NUMBER:
REVISIONS:
PR
O
JE
C
T:
O
UT
D O
O R
FI
TN
ES
S
FA
C
IL
ITY
A T
HO
M
ES
TE
A D
A
IR
R
ES
ER
V
E
BA
SE
(H
A
RB
100% SUBMITTAL: 09/10/20
A U R E L I O
5735 SW 39TH STREET
MIAMI, FL 33155
TEL:305.776.3276
DELGADO
ADALBERTO
HO
M
ES
TE
A D
, F L
MEP ENGINEER
STRUCTURAL ENGINEER
archmiamiaad@gmail.com
AR 0013636
ARCHITECT
C
LI
EN
T:
A D
V A
N C
ED
S
S
PO
B O
X
HU
M A
C A
O , P
.R . 0
PR
O
JE
C
T
: K
YJ
M
9-
C
O
RA
L
SE
A B
O
UL
EV
A
RD
C O
N
TA
C T:
Lu is
A lb er to
R oi g, P
E
C
EO
M O
BI
LE
: 7
-5
-6
EM
A
IL
: a ro ig ad va nc ed ss in c.
co m
AutoCAD SHX Text
1. FLORIDA BUILDING CODE 2017 EDITION. FLORIDA BUILDING CODE 2017 EDITION. 2. ACI 318-14 ACI 318-14 3. A.I.S.C. - STEEL CONSTRUCTION MANUAL 13th EDITION A.I.S.C. - STEEL CONSTRUCTION MANUAL 13th EDITION 4. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) 5. CONCRETE REINFORCING STEEL INSTITUTE (CRSI) CONCRETE REINFORCING STEEL INSTITUTE (CRSI) 6. AMERICAN WELDING SOCIETY (AWS) AMERICAN WELDING SOCIETY (AWS) 7. NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION 8. ACI 530-BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURESACI 530-BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES
AutoCAD SHX Text
1. STRUCTURAL NOTES ARE IN CONFORMANCE WITH THE SPECIFICATIONS FOR THIS PROJECT AND IN STRUCTURAL NOTES ARE IN CONFORMANCE WITH THE SPECIFICATIONS FOR THIS PROJECT AND IN CLARIFICATION THEREOF. 2. ALL MATERIAL, WORKMANSHIP, DESIGN AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, ALL MATERIAL, WORKMANSHIP, DESIGN AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS AND CURRENT BUILDING CODE.
AutoCAD SHX Text
1. LIVE LOADS: FLAT ROOFS ................................................................... 30 PSF 30 PSF SLOPED ROOFS ................................................................. 20 PSF 20 PSF FLOOR RESIDENTIAL ........................................................ 40 PSF 40 PSF LIGHT STORAGE..................................................................125 PSF 2. WIND LOADS AS PER ASCE 7-2010: BASIC WIND SPEED 175 MPH (3-SECOND GUST) 175 MPH (3-SECOND GUST) IMPORTANCE FACTOR 1.00 1.00 EXPOSURE CATEGORY "C" "C" BUILDING CATEGORY II II INTERNAL PRESSURE OPEN OPEN TOPOGRAPHICAL FACTOR 1.001.00
AutoCAD SHX Text
AutoCAD SHX Text
1. ALL CONCRETE DESIGN AND WORK SHALL BE IN ACCORDANCE WITH "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" (ACI 318-14), "SPECIFICATIONS FOR STRUCTURAL CONCRETE" ACI-301, "GUIDE TO FORMWORK FOR CONCRETE" (ACI 347), AND "GUIDE FOR MEASURING, MIXING, TRANSPORTING AND PLACING CONCRETE" (ACI 304R). 2. PORTLAND CEMENT SHALL CONFORM TO ASTM C-150 AND PROJECT SPECIFICATIONS. 3. AGGREGATES FOR HARDROCK CONCRETE SHALL CONFORM TO ALL REQUIREMENTS AND TESTS OF ASTM C-33 AND PROJECT SPECIFICATIONS. 4. CONCRETE MIXING OPERATIONS SHALL CONFORM TO ASTM C-94. 5. MINIMUM CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE AS FOLLOWS: FOOTINGS 3000 PSI 0.72 W/C 3000 PSI 0.72 W/C 0.72 W/C SLABS ON GRADE 3000 PSI 0.72 W/C 3000 PSI 0.72 W/C 0.72 W/C SLABS (U.O.N.) 4000 PSI 0.72 W/C 4000 PSI 0.72 W/C 0.72 W/C COLUMN AND SHEAR WALLS 4000 PSI 0.72 W/C 4000 PSI 0.72 W/C 0.72 W/C BEAMS 4000 PSI 0.72 W/C 4000 PSI 0.72 W/C 0.72 W/C OTHER CONCRETE 3000 PSI 0.72 W/C 0.72 W/C 6. MIX DESIGNS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR COMMENCEMENT OF ANY CONCRETE WORK. 7. CONCRETE SHALL NOT BE DROPPED THROUGH REINFORCING STEEL (AS IN WALLS OR COLUMNS) SO AS TO CAUSE SEGREGATION OF AGGREGATES. USE HOPPERS, CHUTES OR TRUNKS OF VARYING LENGTHS SO THAT THE FREE UNCONFINED FALL OF CONCRETE DOES NOT EXCEEDS 5 FEET. 8. ALL BEAMS, SPANDREL BEAMS AND FLOOR SLABS SHALL BE PLACED MONOLITHICALLY. 9. VERTICAL CONSTRUCTION JOINTS USING APPROVED BULKHEADS MAY BE MADE AT BEAMS OR SLAB SPANS WHERE STOP IN CONCRETE WORK IS NECESSARY. CONSTRUCTION JOINTS REQUESTED BY THE GENERAL CONTRACTOR SHALL BE SHOWN ON THE SHOP DRAWINGS FOR THE ENGINEER'S REVIEW. OTHERWISE CONTRACTOR SHALL SUBMIT BULKHEAD DETAIL AND CONSTRUCTION JOINT LOCATION TO ENGINEER FOR APPROVAL. 10. ALL OPENINGS IN CONCRETE SLABS SHALL BE LOCATED, SIZED AND REINFORCED (WITH THE EXCEPTION OF SMALL OPENINGS AND/OR SLEEVES OF A SIZE THAT WILL NOT DISPLACE OR INTERRUPT THE CONTINUITY OF THE REINFORCING) AS SHOWN ON RESPECTIVE FLOOR PLANS AND TYPICAL DETAILS (SEE TYPICAL SLAB OPENING DETAIL). ANY ALTERATIONS REQUIRE APPROVAL OF THE STRUCTURAL ENGINEER. CORING OF CONCRETE IS NOT PERMITTED UNLESS OTHERWISE SHOWN ON PLANS. 11. ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS SHALL BE WELL SECURE IN POSITION PRIOR TO PLACING CONCRETE. 12. CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECEIVE A RESILIENT TILE FINISH SHALL BE APPROVED BY THE MANUFACTURER BEFORE USE. 13. CONTRACTOR SHALL SUBMIT TO ENGINEER CONCRETE POURING SEQUENCE PRIOR TO CONSTRUCTION. 14. CONDUIT OR PIPE SIZE (O.D.) SHALL NOT EXCEED 30% OF TOTAL SLAB THICKNESS AND SHALL BE PLACED BETWEEN THE TOP AND BOTTOM REINFORCING, UNLESS SPECIFICALLY DETAILED OTHERWISE. CONCENTRATIONS OF CONDUITS OR PIPES SHALL BE AVOIDED EXCEPT WHERE DETAILED OPENINGS ARE PROVIDED. FOR ADDITIONAL INFORMATION REFER TO EMBEDDED PIPE DETAIL ON THE STANDARD DETAILS.
AutoCAD SHX Text
1. STRUCTURAL DRAWING SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND STRUCTURAL DRAWING SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2. WHERE OWNER IS MENTIONED IN DWGS IT IS TO BE UNDERSTOOD EITHER OWNER OR HIS AUTHORIZED WHERE OWNER IS MENTIONED IN DWGS IT IS TO BE UNDERSTOOD EITHER OWNER OR HIS AUTHORIZED REPRESENTATIVE. 3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING FIELD CONDITIONS PRIOR TO STARTING CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING FIELD CONDITIONS PRIOR TO STARTING CONSTRUCTION. IF ANY DISCREPANCY ARISES BETWEEN ACTUAL CONDITIONS AND THE INFORMATION SHOWN ON THE DRAWINGS THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY BEFORE PROCEEDING WITH WORK. 4. IN CASE OF DOUBT IN THE INTERPRETATION OF ANY ASPECT OF THESE STRUCTURAL DRAWINGS AND/OR IN CASE OF DOUBT IN THE INTERPRETATION OF ANY ASPECT OF THESE STRUCTURAL DRAWINGS AND/OR SPECIFICATIONS, THE DESIGNER SHALL BE CONSULTED. 5. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS. IN CASE OF DISCREPANCY DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS. IN CASE OF DISCREPANCY NOTIFY THE EOR. 6. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND STANDARD NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND STANDARD DETAILS. 7. CONTRACTOR MUST VERIFY ALL DIMENSIONS ON STRUCTURAL DWGS AGAINST THE DIMENSIONS ON PROPOSED CONTRACTOR MUST VERIFY ALL DIMENSIONS ON STRUCTURAL DWGS AGAINST THE DIMENSIONS ON PROPOSED CONDITION DWGS BEFORE LAYING OUT THE WORK. 8. CONTRACTOR SHALL REFER TO THE ARCH. DWGS FOR THE FOLLOWING INFORMATION: SIZE AND LOCATION OF CONTRACTOR SHALL REFER TO THE ARCH. DWGS FOR THE FOLLOWING INFORMATION: SIZE AND LOCATION OF ALL DOOR AND WINDOW OPENINGS, SIZE AND LOCATION OF ALL INTERIOR AND EXTERIOR PARTITIONS, SIZE AND LOCATION OF CONCRETE CURBS, FLOOR DRAINS, SLOPES, CHAMFERS, GROOVES, INSERTS ETC., SIZE AND LOCATION OF ALL FLOOR AND ROOF OPENINGS, FLOOR AND ROOF FINISHES, AND DIMENSIONS NOT SHOWN ON STRUCTURAL DWGS. 9. MAIN OPENINGS ARE SHOWN IN THE STRUCTURAL DWGS; HOWEVER, FOR EXACT SIZE AND LOCATION OF ALL MAIN OPENINGS ARE SHOWN IN THE STRUCTURAL DWGS; HOWEVER, FOR EXACT SIZE AND LOCATION OF ALL OPENINGS SEE OTHER DISCIPLINE DWGS. 10. CONTRACTOR SHALL REFER TO MEP DWGS FOR THE FOLLOWING INFORMATION: CONTRACTOR SHALL REFER TO MEP DWGS FOR THE FOLLOWING INFORMATION: PIPE RUNS, SLEEVES, HANGERS, TRENCHES, WALL AND SLAB OPENINGS, SIZE AND LOCATION OF EQUIPMENT OR MACHINE BASES AND ANCHOR BOLTS. 11. OPENINGS LARGER THAN 6" SHALL NOT BE PLACED IN ANY STRUCTURAL ELEMENT UNLESS SPECIFICALLY OPENINGS LARGER THAN 6" SHALL NOT BE PLACED IN ANY STRUCTURAL ELEMENT UNLESS SPECIFICALLY DETAILED ON THE STRUCTURAL DWGS. NOTIFY THE STRUCTURAL ENGINEER WHEN DWGS OF OTHER DISCIPLINES INDICATE OPENINGS LARGER THAN 6". 12. CONSTRUCTION MATERIALS SHALL BE SPREAD EVENLY WHEN PLACED ON FLOORS OR ROOFS. LOADS SHALL CONSTRUCTION MATERIALS SHALL BE SPREAD EVENLY WHEN PLACED ON FLOORS OR ROOFS. LOADS SHALL NOT EXCEED DESIGN LOADS INDICATED ON THE DWGS UNLESS ADEQUATE SHORING IS PROVIDED BY THE CONTRACTOR. 13. THE CONTRACTOR SHALL TAKE PRECAUTIONS TO PRODUCE A CORRECTLY ALIGNED STRUCTURE (COLUMNS, THE CONTRACTOR SHALL TAKE PRECAUTIONS TO PRODUCE A CORRECTLY ALIGNED STRUCTURE (COLUMNS, WALLS, BEAMS, SLABS, ETC.), CONSIDERING AMONG OTHER THINGS, THE ELASTIC DEFORMATION OF THE STRUCTURAL MEMBERS. 14. STRUCTURE HAS BEEN DESIGNED ACCORDING TO FINAL CONDITIONS. HOWEVER DURING ERECTION OF STRUCTURE HAS BEEN DESIGNED ACCORDING TO FINAL CONDITIONS. HOWEVER DURING ERECTION OF STRUCTURE CERTAIN CONDITIONS MAY ARISE FOR WHICH BEHAVIOR OF THE STRUCTURE HAS NOT BEEN CONTEMPLATED. THEREFORE THE CONTRACTOR SHALL PROVIDE AT ALL TIMES ADEQUATE SHORING AND RESHORING AND/OR TEMPORARY ERECTION BRACING AS REQUIRED FOR STABILITY OF THE STRUCTURE DURING ALL CONSTRUCTION STAGES.
AutoCAD SHX Text
1. GEOTECHNICAL INVESTIGATION BY B3 MATERIAL TESTING ENGINEERING., ON REPORT SUBMITTED ON GEOTECHNICAL INVESTIGATION BY B3 MATERIAL TESTING ENGINEERING., ON REPORT SUBMITTED ON 6/20/2020 AND PROJECT NO 20-0253 RECOMMENDS FOR THE PROPOSED STRUCTURE SHALL BE DESIGNED FOR A SHALLOW FOUNDATION SYSTEM WITH A NET STATIC PERMISSIBLE SOIL BEARING PRESSURE OF 3,500 PSF. REFER TO GEOTECHNICAL REPORT FOR ADDITIONAL INFORMATION, EXCAVATION REQUIREMENTS, DEPTH AND COMPACTION RECOMMENDATIONS. 2. CONTRACTOR SHALL BECOME FAMILIAR WITH ALL THE RECOMMENDATIONS ON THE MENTIONED REPORT. FOR CONTRACTOR SHALL BECOME FAMILIAR WITH ALL THE RECOMMENDATIONS ON THE MENTIONED REPORT. FOR QUESTIONS OR CONCERNS PLEASE NOTIFY THE EOR BEFORE CONSTRUCTIONS BEGINS. 3. THE FOLLOWING FOUNDATION RECOMMENDATIONS ARE FROM THE REFERED GEOTECHNICAL INVESTIGATION. THE FOLLOWING FOUNDATION RECOMMENDATIONS ARE FROM THE REFERED GEOTECHNICAL INVESTIGATION.
AutoCAD SHX Text
a. EXCAVATE ENTIRE BUILDING AREA PLUS 5'-0" OUTSIDE THE PERIMETER OF CONSTRUCTION AND REMOVE EXCAVATE ENTIRE BUILDING AREA PLUS 5'-0" OUTSIDE THE PERIMETER OF CONSTRUCTION AND REMOVE ALL TOP SOIL, AND UNSUITABLE SUBSURFACE MATERIAL TO THE NECESSARY DEPTH. WE ANTICIPATE AN AVERAGE EXCAVATION DEPTH OF APPROXIMATELY FOUR (4') FEET. b. COMPACT EXCAVATED AREA TO A MINIMUM COMPACTION OF 98% OF THE OPTIMUM DRY DENSITY AS COMPACT EXCAVATED AREA TO A MINIMUM COMPACTION OF 98% OF THE OPTIMUM DRY DENSITY AS PER AASHTO T-180. VERIFY DENSIFICATION PROCEDURES BY TAKING AN ADEQUATE NUMBER OF FIELD DENSITY COMPACTION TESTS, ESPECIALLY IN THE FOOTING AREA. THE EXCAVATED AREA SHOULD BE INSPECTED PRIOR TO THE COMMENCEMENT OF THE BACKFILLING OPERATION TO ENSURE THAT ALL THE UNSUITABLE MATERIAL HAS BEEN REMOVED. c. BACKFILL BUILDING AREA, PLUS 5'-0" OUTSIDE THE PERIMETER OF THE STRUCTURE TO THE REQUIRED BACKFILL BUILDING AREA, PLUS 5'-0" OUTSIDE THE PERIMETER OF THE STRUCTURE TO THE REQUIRED ELEVATION WITH A CLEAN MIXTURE OF SAND, LIME ROCK AND LIME SAND FILL (OR APPROVED FILL MATERIAL) IN MAXIMUM 10" LOOSE LIFTS TO A MINIMUM OF 98% OF THE OPTIMUM DRY DENSITY AS PER AASHTO T180. d. EXCAVATE FOOTING TRENCHES TO THE REQUIRED DEPTH FROM THE GROUND ELEVATION. ALL TRENCHING EXCAVATE FOOTING TRENCHES TO THE REQUIRED DEPTH FROM THE GROUND ELEVATION. ALL TRENCHING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) REQUIREMENTS. e. DURING EXCAVATION FOR THE PROPOSED IMPROVEMENTS, MOVEMENT OF ADJACENT SOILS INTO THE DURING EXCAVATION FOR THE PROPOSED IMPROVEMENTS, MOVEMENT OF ADJACENT SOILS INTO THE EXCAVATION SHOULD BE PREVENTED. f. EXCAVATE FOOTING TRENCHES TO THE REQUIRED DEPTH FROM THE GROUND ELEVATION. COMPACT THE EXCAVATE FOOTING TRENCHES TO THE REQUIRED DEPTH FROM THE GROUND ELEVATION. COMPACT THE BOTTOM OF THE FOOTING TRENCH TO A MINIMUM COMPACTION OF 98% OF THE OPTIMUM DRY DENSITY AS PER AASHTO g. T- 180. VERIFY DENSIFICATION PROCEDURES BY TAKING AN ADEQUATE NUMBER OF FIELD DENSITY T- 180. VERIFY DENSIFICATION PROCEDURES BY TAKING AN ADEQUATE NUMBER OF FIELD DENSITY 180. VERIFY DENSIFICATION PROCEDURES BY TAKING AN ADEQUATE NUMBER OF FIELD DENSITY COMPACTION TESTS. h. ANY UNDERGROUND STRUCTURES SUCH AS GREASE TRAPS, SEPTIC SYSTEMS, ETC. MUST BE SUPPORTED ANY UNDERGROUND STRUCTURES SUCH AS GREASE TRAPS, SEPTIC SYSTEMS, ETC. MUST BE SUPPORTED ON PILE FOUNDATIONS, UNLESS THE DELETERIOUS MATERIAL (I.E.: SILT, MUCK, PEAT, ETC.) IS EXCAVATED IN ITS ENTIRELY AND REPLACE WITH COMPACTED WASHED GRAVEL SUCH US #57 STONE.
AutoCAD SHX Text
1. ALL CONCRETE DESIGN AND WORK SHALL BE IN ACCORDANCE WITH "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" (ACI 318-14), "SPECIFICATIONS FOR STRUCTURAL CONCRETE" ACI-301, "GUIDE TO FORMWORK FOR CONCRETE" (ACI 347), AND "GUIDE FOR MEASURING, MIXING, TRANSPORTING AND PLACING CONCRETE" (ACI 304R). 2. PORTLAND CEMENT SHALL CONFORM TO ASTM C-150 AND PROJECT SPECIFICATIONS. 3. AGGREGATES FOR HARDROCK CONCRETE SHALL CONFORM TO ALL REQUIREMENTS AND TESTS OF ASTM C-33 AND PROJECT SPECIFICATIONS. 4. CONCRETE MIXING OPERATIONS SHALL CONFORM TO ASTM C-94. 5. MINIMUM CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE AS FOLLOWS: FOOTINGS 3000 PSI 0.72 W/C 3000 PSI 0.72 W/C 0.72 W/C SLABS ON GRADE 3000 PSI 0.72 W/C 3000 PSI 0.72 W/C 0.72 W/C SLABS (U.O.N.) 4000 PSI 0.72 W/C 4000 PSI 0.72 W/C 0.72 W/C COLUMN AND SHEAR WALLS 4000 PSI 0.72 W/C 4000 PSI 0.72 W/C 0.72 W/C BEAMS 4000 PSI 0.72 W/C 4000 PSI 0.72 W/C 0.72 W/C OTHER CONCRETE 3000 PSI 0.72 W/C 0.72 W/C 6. MIX DESIGNS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR COMMENCEMENT OF ANY CONCRETE WORK. 7. CONCRETE SHALL NOT BE DROPPED THROUGH REINFORCING STEEL (AS IN WALLS OR COLUMNS) SO AS TO CAUSE SEGREGATION OF AGGREGATES. USE HOPPERS, CHUTES OR TRUNKS OF VARYING LENGTHS SO THAT THE FREE UNCONFINED FALL OF CONCRETE DOES NOT EXCEEDS 5 FEET. 8. ALL BEAMS, SPANDREL BEAMS AND FLOOR SLABS SHALL BE PLACED MONOLITHICALLY. 9. VERTICAL CONSTRUCTION JOINTS USING APPROVED BULKHEADS MAY BE MADE AT BEAMS OR SLAB SPANS WHERE STOP IN CONCRETE WORK IS NECESSARY. CONSTRUCTION JOINTS REQUESTED BY THE GENERAL CONTRACTOR SHALL BE SHOWN ON THE SHOP DRAWINGS FOR THE ENGINEER'S REVIEW. OTHERWISE CONTRACTOR SHALL SUBMIT BULKHEAD DETAIL AND CONSTRUCTION JOINT LOCATION TO ENGINEER FOR APPROVAL. 10. ALL OPENINGS IN CONCRETE SLABS SHALL BE LOCATED, SIZED AND REINFORCED (WITH THE EXCEPTION OF SMALL OPENINGS AND/OR SLEEVES OF A SIZE THAT WILL NOT DISPLACE OR INTERRUPT THE CONTINUITY OF THE REINFORCING) AS SHOWN ON RESPECTIVE FLOOR PLANS AND TYPICAL DETAILS (SEE TYPICAL SLAB OPENING DETAIL). ANY ALTERATIONS REQUIRE APPROVAL OF THE STRUCTURAL ENGINEER. CORING OF CONCRETE IS NOT PERMITTED UNLESS OTHERWISE SHOWN ON PLANS. 11. ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS SHALL BE WELL SECURE IN POSITION PRIOR TO PLACING CONCRETE. 12. CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECEIVE A RESILIENT TILE FINISH SHALL BE APPROVED BY THE MANUFACTURER BEFORE USE. 13. CONTRACTOR SHALL SUBMIT TO ENGINEER CONCRETE POURING SEQUENCE PRIOR TO CONSTRUCTION. 14. CONDUIT OR PIPE SIZE (O.D.) SHALL NOT EXCEED 30% OF TOTAL SLAB THICKNESS AND SHALL BE PLACED BETWEEN THE TOP AND BOTTOM REINFORCING, UNLESS SPECIFICALLY DETAILED OTHERWISE. CONCENTRATIONS OF CONDUITS OR PIPES SHALL BE AVOIDED EXCEPT WHERE DETAILED OPENINGS ARE PROVIDED. FOR ADDITIONAL INFORMATION REFER TO EMBEDDED PIPE DETAIL ON THE STANDARD DETAILS.
AutoCAD SHX Text
1. REINFORCING STEEL BARS SHALL BE HIGH STRENGTH, GRADE 60, DEFORMED NEW BILLET STEEL CONFORMING REINFORCING STEEL BARS SHALL BE HIGH STRENGTH, GRADE 60, DEFORMED NEW BILLET STEEL CONFORMING TO ASTM A615 SPECIFICATION. BARS SHALL BE FREE FROM LOOSE RUST AND SCALE. 2. ALL REINFORCING SHALL BE DETAILED AND FABRICATED FOLLOWING THE REQUIREMENTS OF ACI 315. PLACING ALL REINFORCING SHALL BE DETAILED AND FABRICATED FOLLOWING THE REQUIREMENTS OF ACI 315. PLACING OF REBARS SHALL CONFORM TO "CRSI RECOMMENDED PRACTICES FOR PLACING REINFORCING BARS". 3. ALL BARS SHALL BE SPACED AND SUPPORTED WITH THE USE OF APPROVED ADEQUATE DEVICES. SUPPORT ALL BARS SHALL BE SPACED AND SUPPORTED WITH THE USE OF APPROVED ADEQUATE DEVICES. SUPPORT BARS SHALL BE #5 OR GREATER, AND NOT SPACED MORE THAN 1'-6" C/C. SUPPORT BARS AND ENDS OF MAIN REINFORCING SHALL NOT EXTEND MORE THAN 1'-6" PAST OUTERMOST CHAIR OR SUPPORT BAR. 4. A MINIMUM OF 3 SUPPORT BARS AND 3 INDIVIDUAL HIGH CHAIRS FOR EACH SUPPORT BAR SHALL BE A MINIMUM OF 3 SUPPORT BARS AND 3 INDIVIDUAL HIGH CHAIRS FOR EACH SUPPORT BAR SHALL BE PROVIDED FOR TOP REINFORCING. 5. SLAB BOLSTERS SHALL BE PROVIDED FOR COLUMN VERTICAL REINFORCING STEEL, SUCH THAT 1 INCH SLAB BOLSTERS SHALL BE PROVIDED FOR COLUMN VERTICAL REINFORCING STEEL, SUCH THAT 1 INCH 12 INCH MINIMUM CLEARANCE IS MAINTAINED. A SAMPLE SHALL BE SENT TO THE ENGINEER FOR APPROVAL. 6. REINFORCING IS DENOTED ON PLANS AS FOLLOWS: DENOTES TOP STEEL DENOTES BOTTOM STEEL 7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 AND SHALL BE SUPPORTED ON SLAB BOLSTERS. USE FLAT SHEETS ONLY. MINIMUM LAP SHALL BE 6" OR ONE FULL MESH, WHICHEVER IS GREATER. 8. ALL WALLS AND COLUMNS SHALL BE DOWELED INTO FOOTINGS W/ A 90° HOOK IN CONTACT W/ FOOTING IS BOTTOM REINFORCEMENT AND EXTENDING THE REQUIRED LAP LENGTH ABOVE FOOTING TOP SURFACE.
This is the start of the file's text. The full file is on GovTribe.