This document appears to be Attachment 3 - Drawings for the federal contract opportunity 68cc5a6a8842467dab701cb8069b7915, Solicitation Number 36C77624B0028, titled "Y1DA--675-22-701 EHRM Infrastructure Upgrades Construction Lake Baldwin (Orlando)". The contract opportunity is issued by the Department of Veterans Affairs Technology Acquisition Center Austin for EHRM Infrastructure Upgrades Construction at the Lake Baldwin location in Orlando. The Attachment 3 - Drawings document provides technical drawings and specifications related to the construction requirements of this solicitation. It does not contain any details on the products or services required, response dates, pricing terms, or other salient information about the contract opportunity itself. This appears to be a technical drawing attachment rather than the main solicitation document.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DR. WILLIAMS
DR. LEE
DR. JAIME
TEAM
WORK
PA POPE
MEDS
1412B
TOILET
1411A TOILET
1430A
STAFF
TOILET
CONSULTATION
EXAM
CORRIDOR
E102A
DR. PATEL
DR. MARKUCK
TREATMENT
ROOM
DR. TOMPSON
TOILET
1427A
PAT
TOILET
TOILET
1425A
PAT
TOILET
CONFERENCE
ROOM
1412A
CONSULATION
EXAM
CONSULTATION
EXAM RM
CONSULT
CORRIDOR
E101
CORRIDOR
CORRIDOR
E102C
CORRIDOR
CORRIDOR
E107
CORRIDOR
E106
CORRIDOR
E104
EXAM
EXAM
EXAM
TREATMENT
ROOM
ELECT
ROOM
HAS
RECEPTION DESK / CHECK IN
1420A
CDE
MENTAL
HEALTH
PHARAMACY
DIETICIAN
OFFICE
OFFICE
OFFICE
OFFICE
I T
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
PSYCHOLOGY
PSYCHOLOGY
PSYCHOLOGY
PSYCHOLOGY
PSYCHOLOGY
OFFICE
OFFICE
OFFICE
OFFICE
RECEPTION
SOIL
HOLD
WORK
STATIONS
WORK
STATIONS
HAC
1429A
WAITING
ROOM
W H C
R
EC
EP
TIO
N D
ES
K
C H
EC
K
IN
CORRIDOR
E103
CORRIDOR
E102B
STORAGE
WORK
ROOM
STORAGE
TOILET
1425A
EXAM
TREATMENT
ROOM
HAC
1429A
EXAM
EXAM
EXAM
STAFF LOUNGE
EXAM / OFFICE
FILE
ROOM
1451A
12'
25'-3 1_
'-4 1 _ 2
17'-11 1_
'-1
1 _ _ 1
WC
SCALE
ALCOVE
15'
1131A
SOILED CART
LIFT-2
DIRTY CART
LIFT-1
1615B 1616A
1612A
1508 1509
1720E
1720CA
C
LE
A N
C A
R T
LI
F
T -3
1723A
1720AA
1092A
1711C
1711B 1715P
1715N
1715K
1711D
1711CA
CORRIDOR
1715Q
1711A
1727A
1727B
CLEAN
1720G
1713E
1801B
1715FA
1715H1715G
1715F
1715E1715D 1715C
1715A 1715B
1703A
1704A
FAMILY CARE
TOILET
1817 1824
1720C
1720B
1720A
1715M
1715R
1715L
STAIR-1
WAITING
1481A
1516A
1513A
1615A
CORRIDORCORRIDOR
CORRIDOR
CORRIDOR
1607B
1607C
1607A
1607D
1621A
1481 1510 1511
1611B
WOMENS TOILET
MENS TOILET
1600A
DR OFFICE
1497B
1497A
1118B
1107D
1107C
1107A
1107B
1097A
19041905
19021901
19001907
CORRIDOR
1075A
1111A
1123B
1039A
DRESSING
10881087
109310911090108510841064
AREAWAY
FEC AND FDV
FEC AND FDV
FEC AND FDV
FEC
UP
UP
CONC FILLED
PIPE GUARD
DN
SUMP W/GRATING
DN
LINE OF CANOPY ABOVE
AREAWAY AREAWAY
BRICK SCREEN WALL
LINE OF CANOPY ABOVE
REFRIGERATOR
DOWN
FEC
SLOPE DOWN
TRAY LINE
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD FD FD FD
FD
CADDY
SORTING VEYOR
DISH MACHINE
FD
FD
IN
FD
FD
FD
AB
B A
K E
R Y
COUNTRY COOKING
1611A
1715K
1604A 1604B
WAITING
1815A
1715J
RACK
CART
WASHER
C A
R T
W A
S H
E R
S H
E
LV
E S
S H
E
LV
E S
LOCKERS
STEAM
STERALIZER
ETO 1
ETO 2
TABLE
REF
SHELVESTRASH
CTR
LOCKERS
FE
WASHERWASHER W
IN
D O
W P
A S
S -T
H R
U
STEAM
STERALIZER
FILE
LINEN
CART
LINEN
CART
ELECT.
LI
N
E N
C A
R T
WRAP
RACK
SONIC
WASHER
S O
N
IC
W A
S H
E R
RACK
NON-BIO
IMPLANT
CART
LINEN
CART
LINEN
CART
SHELF
SHELF
LOCKERS
FLAM.
CAB
FLAM.
CAB
CH
CH
CH
CH
CH
CH
CH
CH
FD
FD
FD
1827A
1720A
Kitchen Door
S H
E
LV
E S
SHELVES
FEC
FEC
EWC
EWC
FE
C
FEC
FHVC
C O F F E E
V E N D
IN
G
M A C H
TV TV
TV
C H
IP
V E N D
IN
G
M A C H
S O D A
V E N D
IN
G
M A C H
LVT
TV
HM WKST
FILE CAB
FILE CAB
RICOH
TAB TAB
TAB
TAB
RICOH
SCALE
KID'S BKCASE
BOOKCASE
1713B
1713C
R E
F
RICOH
16001493
COUNTER
EYE
CLINIC
RECEPTIONWAITING
1801A
UP
EMERGENCY
EXIT
PRINTER
L
ST
O R
C
AB
ST
O R
C
AB
ST
O R
C
AB
'-8 1 _ _ 1
'-6
7'-3 11__
Measures 6 ft. Pencil Tree with 10" in. base diameter, when fully shaped
Measures 6 ft. Pencil Tree with 10" in. base diameter, when fully shaped
FEC
3 4 5
S P R U C E
S P R U C E
S P R U C E
S P R U C E
S P R U C E
SPRUCESPRUCE SPRUCESPRUCE
S P R U C E
S P R U C E
DN
REF.
DN
1812A
1802A
1814E
1802E
1802D
1807A
1814A
1800A
1807B
1807C
1814C
1814G
XX XX
X
XX
XX
53K3060WBULKIMKLB10.000000
P R
IO
R
IT
Y
45F6260BS3SELLKIMKLP10.000000
45F13GCARP KIMKLP10.000000
COUNTER
COUNTER
1306Q
1306M
1306C
1304K
1309J
1309H
1309A
1309C
1309D1306P
1306R
1306S
1306N1306U
1306I 1306G
1309E
1309M
1309L 1213A
1213G
1306L1306K1306J1306F
1213K
1304G
1304F
1304D
1306E
1306B
1306D1304M
1214A
1304B
1304A
1304E
1304C
1210F
1106A
1306H 1303A
1210G
FEC AND FDV
FEC AND FDV
FEC AND FDV
FEC AND FDV
FEC AND FDV
COUNTER
1213H
1214B
E
LE
C T
R
IC
A L
P A
N E
L
1213J
8" A
F F
0" A
F F
8" A
F F
@ 48"AFF
TV
TV
TV
T V
TV
TV
1213B
1213C1213D1213E1213F
1214C
1213L
1304H
EXIST
CHASE
VESTIBULE
VESTIBULE
FEMALE TOILET
MENS TOILET
F E
C
F E
C
FEC
FEC
VRE STORAGE
VRE OFFICE
C O
R R
ID
O
R
WAITING ROOM 1
VRE OFFICE
ASSIST OFFICE
COACH OFFICE
C O
R R
ID
O
R
COPY
COPY
CORRIDOR
SECURITY VESTIBULE
CONTR OFICE
OPEN OFFICE 2
CORRIDOR
C O
R R
ID
O
R
OPEN OFFICE 3
CORRIDOR
103A
CONF
STOR
SUPER OFF
SUPER OFF
DIRECTOR
ELEC
STORAGE
WOMENS TOILET
SUPER
STORAGE
161A
UNISEX
VRE OFFICE
CLOS
103B
SUPER OFF
VRE OFFICE
VRE OFFICE
VRE OFFICE
VRE OFFICE
VRE OFFICE
MENS TOILET
HAC
BREAK ROOM
C O
R R
ID
O
R
OPEN OFFICE 7
CORRIDOR
OPEN OFFICE 1
EXIST ELEC
EXIST IRMS
VRE OFFICE
MOTHERS ROOM
C O
R R
ID
O
R
CONF B
CONF A
FILE RM
SM CONF
VRE OFFICE
DAV OFFICE
VRE OFFICE
VRE OFFICE
AFGE OFFICE
STORAGE
COPY
D A
V R
E C
E P
T
VESTIBULE
WAITING ROOM 3
C O
R R
ID
O
R
VRE OFFICE
VRE OFFICE
VRE OFFICE
WORK STATION
130A
VRE OFFICE
VRE OFFICE
VRE OFFICE
C O
R R
ID
O
R B
WAITING ROOM 2
OPEN OFFICE 6
CONF
WORKSTATION
RECEPT
VRE OFFICE
MULTIPURPOSE/TRAINING
FILE ROOM
CORRIDOR
C O
R R
ID
O
R
DRAW
DRAW
DRAW
DRAW
DRAW
PHLEBOLOMY
SUP CLOSET
OFFICE
M TLT
W TLT
M TLT
W TLT
STAFF TLT
JNTR
STAFF LACT.
ROOM
PROCESSING
SUPPLY CLOSET
STAFF
ENTRY/EXIT
SPECIMEN
PROCESS
FRONT DESK/
SPEC LOG-IN
DRAW
DRAW
WAITING AREA
RECLINED DRAW
VOL. INFO
CENTER
PATIENT
ADVOCATE
HAS
W TLT
M TLT
BREAK ROOM
OFFICE
SAFETY ROOM
WAITING AREA 3
BARIC DRAW
S P R U C E
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD FD FD FD
FD
FD
FD
FD
FD
FD
FD
FD
R E F
NEW TR ZONE 4
1713D
1451A
NEW TR ZONE 1
NEW TR ZONE 5
NEW TR ZONE 3
NEW TR ZONE 2
FX401
FX401
FX401
FX401
FX401
FX402
FX402
FX402
FX402
FX402
KEYNOTES
1 REFER TO REFERENCED SHEET FOR ENLARGED VIEW. TYP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL - BID
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD
A/E:
STAMPENGINEER OF RECORD
321 4 5 6 7 8 9 10
AESUS DESIGN GROUP
1050 E. Southern Ave., Suite D
Temple, AZ, 85282
480-454-2861
David Combs
EHRM VA LAKE BALDWIN 675-22-701
5201 Raymond St. Orlando, FL 32803
Dec. .22, 2023
Mechanical, Electrical, Plumbing, & Fire Protection
D R e v it L o c a l\ \2
V
A L a k e B a ld w in
E H
R M
M
E P
R
V
O L T
K y le
.M c C u lli n .r v t
/2
/2
:4 :2
P
M
FX101
BUILDING 500 FIRST FLOOR
OVERALL PLAN - FIRE PROTECTION
NS ANK/KM
MES Group, Inc.
550 Norrth Reo Street
Tampa, FL, 33609
813-289-4700
Nicholas Stephenson
1/16" = 1'-0"FX101
1 BUILDING 500 FIRST FLOOR OVERALL PLAN - FIRE PROTECTION
Revisions: Date:
12/20/2023
C R
MAIL ROOM
STORAGE
LINEN ROOM
ABOVE
RECEIVING
MEZZANINE
OFFICE
OFFICEOFFICE
OFFICEOFFICE
OFFICE OFFICE OFFICE
EWC
ELEC.
TOILET
MENSTOILET
LADIES
HAC
A&MMS
CLINIC EQUIPMENT STORAGE
VAULTOFFICE
REFRIDG. STORAGE
OFFICE
WAREHOUSE
15,250 sq.ft.
IMS OFFICE
Mezzanine
STORAGE
CORRIDOR
CORRIDOR
PURCHASING
OH DOOR
101a
101b
105104
112 113 114
108a
124109
OH DOOR
F.P.
C R
C R
TE CLOSET
102B
FX102
FX102
FIRE PROTECTION SPRINKLER SYSTEM DESIGN CRITERIA
SPACE TYPE
HAZARD
CLASSIFICATION
SYSTEM
TYPE
DISCHARGE
DENSITY
REMOTE
AREA
MAXIMUM
COVERAGE
AREA PER
SPRINKLER
MAXIMUM
SPACING
WATER
SUPPLY
DURATION
OUTSIDE
HOSE
ALLOWANCE
TEMPERATURE
CLASSIFICATION
SPRINKLER TYPE NOTES
GPM/FT² FT² FT² FT. MINUTES GPM
GENERAL,
EXCEPT AS
LISTED BELOW
LIGHT HAZARD WET PIPE 0.10 1,500 225 15 30 100 ORDINARY
SEMI-RECESSED
PENDENT, QUICK
RESPONSE, UL LISTED, FM
APPROVED
STORAGE
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 ORDINARY
SEMI-RECESSED
PENDENT OR UPRIGHT,
QUICK RESPONSE,
UL LISTED, FM APPROVED
EQUIPMENT
ROOM
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 INTERMEDIATE
QUICK RESPONSE
UPRIGHT, UL LISTED, FM
APPROVED
HOUSEKEEPING
CLOSET
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 ORDINARY
PENDENT OR UPRIGHT,
QUICK RESPONSE,
UL LISTED, FM APPROVED
ELEVATOR
EQUIPMENT
ROOM
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 INTERMEDIATE PER NFPA 13 1
NOTES:
1. WATER DEMAND REQUIREMENTS ARE FOR HYDRAULIC CALCULATION METHOD. IF OTHER METHOD IS USED ADJUST VALUES ACCORDING TO NFPA 13 REQUIREMENTS.
HAZARD
SYMBOL
TE CLOSET
102B
F1
F1
F2
TE CLOSET
102B
FIRE PROTECTION NOTES
F1. APPROXIMATE LOCATION OF EXISTING SPRINKLER HEAD, FIELD COORDINATE
EXACT LOCATION PRIOR TO CONSTRUCTION. PROVIDE ADDITIONAL HEADS AS
REQUIRED FOR REVISED BACKGROUND.
F2. PROVIDE NEW SPRINKLER HEAD AS REQUIRED IN TE ROOM TO MATCH EXISTING.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL - BID
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD
A/E:
STAMPENGINEER OF RECORD
321 4 5 6 7 8 9 10
AESUS DESIGN GROUP
1050 E. Southern Ave., Suite D
Temple, AZ, 85282
480-454-2861
David Combs
EHRM VA LAKE BALDWIN 675-22-701
5201 Raymond St. Orlando, FL 32803
Dec. .22, 2023
Mechanical, Electrical, Plumbing, & Fire Protection
D R e v it L o c a l\ \2
V
A L a k e B a ld w in
E H
R M
M
E P
R
V
O L T
K y le
.M c C u lli n .r v t
/2
/2
:4 :2
P
M
FX102
BUILDING 501 PLANS - FIRE
PROTECTION
NS ANK/KM
MES Group, Inc.
550 Norrth Reo Street
Tampa, FL, 33609
813-289-4700
Nicholas Stephenson
1/8" = 1'-0"FX102
1 LEVEL 1 - BUILDING 501 OVERALL - FIRE PROTECTION
1/4" = 1'-0"FX102
2 LEVEL 1 - BUILDING 501 - ROOM 102A HAZARD PLAN
1/4" = 1'-0"FX102
3 LEVEL 1 - BUILDING 501 - ROOM 102A FIRE PROTECTION
OFFICE
TOILET
CLOSET
JANITOR
(E) GENERATOR
ROOM
(E) EMERGENCY GENERATOR
(E) EMERGENCY GENERATOR
AIR
(E) MEDICAL
AIR
(E) DENTAL
VACUUM
(E) MEDICAL
(E) BOILER/GENER. F.O. PUMPS
(E) DHW STORAGE TANK
(E) EMERGENCY GENERATOR (E) SURGE TANK
(E) DEAERATOR TANK
(E) BOILER 1 (E) BOILER 2
ROOM
(E) BOILER
SUMP PIT
(E) WATER TREATMENT
(N) CH-3(E) CH-5
(E) FIRE PUMP
(E) CH-2(E) CH-1OPEN
OH DOOR
LOUVER
OH DOOR
LOUVER
WINDOW
OPEN
C R
OFFICE
TOILET
CLOSET
JANITOR
WINDOW
C R
OFFICE
TOILET
CLOSET
JANITOR
WINDOW
FX103
FX103
FIRE PROTECTION NOTES
F1. APPROXIMATE LOCATION OF EXISTING SPRINKLER HEAD. EXISTING SPRINKLER
HEAD TO REMAIN.
F2. APPROXIMATE LOCATION OF EXISTING SPRINKLER, RECONFIGURE AND
PROVIDE NEW UPRIGHT SPRINKLER HEAD WITH CAGE AS REQUIRED IN TELECOM
ROOM .
FIRE PROTECTION SPRINKLER SYSTEM DESIGN CRITERIA
SPACE TYPE
HAZARD
CLASSIFICATION
SYSTEM
TYPE
DISCHARGE
DENSITY
REMOTE
AREA
MAXIMUM
COVERAGE
AREA PER
SPRINKLER
MAXIMUM
SPACING
WATER
SUPPLY
DURATION
OUTSIDE
HOSE
ALLOWANCE
TEMPERATURE
CLASSIFICATION
SPRINKLER TYPE NOTES
GPM/FT² FT² FT² FT. MINUTES GPM
GENERAL,
EXCEPT AS
LISTED BELOW
LIGHT HAZARD WET PIPE 0.10 1,500 225 15 30 100 ORDINARY
SEMI-RECESSED
PENDENT, QUICK
RESPONSE, UL LISTED, FM
APPROVED
STORAGE
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 ORDINARY
SEMI-RECESSED
PENDENT OR UPRIGHT,
QUICK RESPONSE,
UL LISTED, FM APPROVED
EQUIPMENT
ROOM
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 INTERMEDIATE
QUICK RESPONSE
UPRIGHT, UL LISTED, FM
APPROVED
HOUSEKEEPING
CLOSET
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 ORDINARY
PENDENT OR UPRIGHT,
QUICK RESPONSE,
UL LISTED, FM APPROVED
ELEVATOR
EQUIPMENT
ROOM
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 INTERMEDIATE PER NFPA 13 1
NOTES:
1. WATER DEMAND REQUIREMENTS ARE FOR HYDRAULIC CALCULATION METHOD. IF OTHER METHOD IS USED ADJUST VALUES ACCORDING TO NFPA 13 REQUIREMENTS.
HAZARD
SYMBOL
TE CLOSET
F1
F1
F1
F2
TE CLOSET
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL - BID
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD
A/E:
STAMPENGINEER OF RECORD
321 4 5 6 7 8 9 10
AESUS DESIGN GROUP
1050 E. Southern Ave., Suite D
Temple, AZ, 85282
480-454-2861
David Combs
EHRM VA LAKE BALDWIN 675-22-701
5201 Raymond St. Orlando, FL 32803
Dec. .22, 2023
Mechanical, Electrical, Plumbing, & Fire Protection
D R e v it L o c a l\ \2
V
A L a k e B a ld w in
E H
R M
M
E P
R
V
O L T
K y le
.M c C u lli n .r v t
/2
/2
:4 :2
P
M
FX103
BUILDING 502 PLANS - FIRE
PROTECTION
NS ANK/KM
MES Group, Inc.
550 Norrth Reo Street
Tampa, FL, 33609
813-289-4700
Nicholas Stephenson
1/8" = 1'-0"FX103
1 LEVEL 1 - BUILDING 502 OVERALL - FIRE PROTECTION
1/4" = 1'-0"FX103
2 LEVEL 1 - BUILDING 502 OVERALL - HAZARD PLAN
1/4" = 1'-0"FX103
3 LEVEL 1 - BUILDING 502 OVERALL - FIRE PROTECTION PLAN
CR
FEMALE
HC TOILET163
FEMALE
HC TOILET131
FEMALE
HC TOILET193
FIRE RISER
RM 197
PROCED
RECEPTION
WAITING
RECEPTION
WAITING
CORRIDOR
WAITING
RECEPTION
CORRIDOR
C O
R R
ID
O
R
3 CORRIDOR
HAC
MALE HC
TOILET
DOCTOR
OFFICE
HAC
C O
R R
ID
O
R
C O
R R
ID
O
R
C O
R R
ID
O
R
C O
R R
ID
O
R
HAC
MALE HC
TOILET191
NURSING
STATION
EXAM RM
EXAM RM
DR KESSLER
OFFICE
DOCTOR
OFFICE
EXAM RM
EXAM RM
Dr. Arnott189
DR. MAHMOOM'S
EXAM RM
DR MAHMOOM &
OTHER DR'S OFFICE
EXAM RM
STAFF
TOILET
STAFF RM
EXAM RM
DOCTOR
OFFICE
EXAM RM
SOCIAL
WORKER190
MALE HC
TOILET
DIETITIAN
HAS
PHARMACY
PHARMACY
EXAM RM
EXAM RM
DOCTOR
OFFICE174
DOCTOR
OFFICE147
EXAM RM
EXAM RM
NURSING
STATION153
EXAM RM
EXAM RM
DOCTOR
OFFICE
DOCTOR
OFFICE
EXAM RM
EXAM RM
TEAM
CO-ORDR
DIETITIAN
PROCED
PHARMACY
EXAM RM
EXAM RM
DOCTOR
OFFICE
DOCTOR
OFFICE
EXAM RM
EXAM RM
NURSING
STATION
EXAM RM
EXAM RM
DOCTOR
OFFICE
DOCTOR
OFFICE
EXAM RM
EXAM RM
SOCIAL
WORKER
HAS
PROCED
EXAM RM
DOCTOR
OFFICE
EXAM RM
ELECTRICAL RM
EXAM RM
DOCTOR
OFFICE
EXAM RM
STAFF RM
STAFF
TOILET
EXAM RM
STAFF RM
STAFF
TOILET
VESTIBULEVESTIBULEVESTIBULE
AUDITORIUM AUDITORIUM
101A 101B
ORANGE
TEAM
PURPLE
TEAM
TEAL TEAM
DR. QADR
EXAM RM
DR QADR
OFFICE
CORRIDOR
CR
CR
TR
102A
FX104
TR
FX104
FIRE PROTECTION NOTES
F1. APPROXIMATE LOCATION OF EXISTING UPRIGHT SPRINKLER HEAD. EXISTING
SPRINKLER HEAD TO REMAIN.
F2. APPROXIMATE LOCATION OF EXISTING SPRINKLER, RECONFIGURE AND
PROVIDE NEW UPRIGHT SPRINKLER HEAD WITH CAGE AS REQUIRED IN TELECOM
ROOM .
FIRE PROTECTION SPRINKLER SYSTEM DESIGN CRITERIA
SPACE TYPE
HAZARD
CLASSIFICATION
SYSTEM
TYPE
DISCHARGE
DENSITY
REMOTE
AREA
MAXIMUM
COVERAGE
AREA PER
SPRINKLER
MAXIMUM
SPACING
WATER
SUPPLY
DURATION
OUTSIDE
HOSE
ALLOWANCE
TEMPERATURE
CLASSIFICATION
SPRINKLER TYPE NOTES
GPM/FT² FT² FT² FT. MINUTES GPM
GENERAL,
EXCEPT AS
LISTED BELOW
LIGHT HAZARD WET PIPE 0.10 1,500 225 15 30 100 ORDINARY
SEMI-RECESSED
PENDENT, QUICK
RESPONSE, UL LISTED, FM
APPROVED
STORAGE
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 ORDINARY
SEMI-RECESSED
PENDENT OR UPRIGHT,
QUICK RESPONSE,
UL LISTED, FM APPROVED
EQUIPMENT
ROOM
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 INTERMEDIATE
QUICK RESPONSE
UPRIGHT, UL LISTED, FM
APPROVED
HOUSEKEEPING
CLOSET
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 ORDINARY
PENDENT OR UPRIGHT,
QUICK RESPONSE,
UL LISTED, FM APPROVED
ELEVATOR
EQUIPMENT
ROOM
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 INTERMEDIATE PER NFPA 13 1
NOTES:
1. WATER DEMAND REQUIREMENTS ARE FOR HYDRAULIC CALCULATION METHOD. IF OTHER METHOD IS USED ADJUST VALUES ACCORDING TO NFPA 13 REQUIREMENTS.
HAZARD
SYMBOL
TR
102A
TR
F2 F1
TR
102A
TR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL - BID
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD
A/E:
STAMPENGINEER OF RECORD
321 4 5 6 7 8 9 10
AESUS DESIGN GROUP
1050 E. Southern Ave., Suite D
Temple, AZ, 85282
480-454-2861
David Combs
EHRM VA LAKE BALDWIN 675-22-701
5201 Raymond St. Orlando, FL 32803
Dec. .22, 2023
Mechanical, Electrical, Plumbing, & Fire Protection
D R e v it L o c a l\ \2
V
A L a k e B a ld w in
E H
R M
M
E P
R
V
O L T
K y le
.M c C u lli n .r v t
/2
/2
:4 :2
P
M
FX104
BUILDING 504 PLANS - FIRE
PROTECTION
NS ANK/KM
MES Group, Inc.
550 Norrth Reo Street
Tampa, FL, 33609
813-289-4700
Nicholas Stephenson
1/8" = 1'-0"FX104
1 LEVEL 1 - BUILDING 504 OVERALL - FIRE PROTECTION
3/8" = 1'-0"FX104
2 LEVEL 1 - BUILDING 504 OVERALL - HAZARD PLAN
3/8" = 1'-0"FX104
3 LEVEL 1 - BUILDING 504 OVERALL - FIRE PROTECTION PLAN
TYPE-A ONE
BED RM
ELECTRICAL
RM
LOBBY
WOMENS
TOILET
MENS
TOILET
TYPE-A ONE
BED RM
TYPE-A ONE
BED RM
TYPE-A ONE
BED RM
TYPE-A ONE
BED RM
TYPE-A ONE
BED RM
BLDG 520 AELEVATOR
MACH RM
ELEVATOR
SHAFT
BATH BATH BATH
MECH
ELECTRICAL
ADA ONE
BED ROOM
ADA ONE
BED ROOM
ADA ONE
BED ROOM
ONE BED RM
ADA ONE
BED ROOM
ADA ONE
BED ROOM
BATH
BATH
BATH
HAC
120A
LIBRARY
WOMENS
TOILET
OFFICEOFFICEEXAM RM
NURSE
OFFICE
QUIET RM
MENS
TOILET
MENS
TOILET
NURSE
OFFICE
WOMENS
TOILET
WALKWAY
OFFICE
TOILET
TOILET
OFFICE
OFFICE
OFFICE
CLERICAL
RM
DOM
CHIEF
ELECTRICAL
RM
PATIENT TV
LOUNGE
KITCHEN
EDUC GROUP RM
FOLDING
PARTITION
BLDG 519A
COMPUTER
RM
STORAGE
KITCHEN
BLDG 519
BLDG 521
131 133132
107 108 109 110 111
134 135
107A 109A 111A
113B
113A
114A
116A
118A
121A
121122123
123A
101A
105A
106 106
C R
PARTITION
C R
PARTITION
TR
137A
FX105
FX105
FIRE PROTECTION NOTES
F1. EXISTING CONCEALED SPRINKLER HEAD (APPROXIMATE LOCATIONS) TO BE
REMOVED.
F2. PROVIDE UPRIGHT SPRINKLER HEAD WITH CAGE AS REQUIRED IN TELECOM
ROOM . SPRINKLER HEAD SHALL BE LOCATED AT CENTER OF THE ROOM.
FIRE PROTECTION SPRINKLER SYSTEM DESIGN CRITERIA
SPACE TYPE
HAZARD
CLASSIFICATION
SYSTEM
TYPE
DISCHARGE
DENSITY
REMOTE
AREA
MAXIMUM
COVERAGE
AREA PER
SPRINKLER
MAXIMUM
SPACING
WATER
SUPPLY
DURATION
OUTSIDE
HOSE
ALLOWANCE
TEMPERATURE
CLASSIFICATION
SPRINKLER TYPE NOTES
GPM/FT² FT² FT² FT. MINUTES GPM
GENERAL,
EXCEPT AS
LISTED BELOW
LIGHT HAZARD WET PIPE 0.10 1,500 225 15 30 100 ORDINARY
SEMI-RECESSED
PENDENT, QUICK
RESPONSE, UL LISTED, FM
APPROVED
STORAGE
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 ORDINARY
SEMI-RECESSED
PENDENT OR UPRIGHT,
QUICK RESPONSE,
UL LISTED, FM APPROVED
EQUIPMENT
ROOM
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 INTERMEDIATE
QUICK RESPONSE
UPRIGHT, UL LISTED, FM
APPROVED
HOUSEKEEPING
CLOSET
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 ORDINARY
PENDENT OR UPRIGHT,
QUICK RESPONSE,
UL LISTED, FM APPROVED
ELEVATOR
EQUIPMENT
ROOM
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 INTERMEDIATE PER NFPA 13 1
NOTES:
1. WATER DEMAND REQUIREMENTS ARE FOR HYDRAULIC CALCULATION METHOD. IF OTHER METHOD IS USED ADJUST VALUES ACCORDING TO NFPA 13 REQUIREMENTS.
HAZARD
SYMBOL
TR
137A
F1
F2
F1
F1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL - BID
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD
A/E:
STAMPENGINEER OF RECORD
321 4 5 6 7 8 9 10
AESUS DESIGN GROUP
1050 E. Southern Ave., Suite D
Temple, AZ, 85282
480-454-2861
David Combs
EHRM VA LAKE BALDWIN 675-22-701
5201 Raymond St. Orlando, FL 32803
Dec. .22, 2023
Mechanical, Electrical, Plumbing, & Fire Protection
D R e v it L o c a l\ \2
V
A L a k e B a ld w in
E H
R M
M
E P
R
V
O L T
K y le
.M c C u lli n .r v t
/2
/2
:4 :3
P
M
FX105
BUILDING 519 PLANS - FIRE
PROTECTION
NS ANK/KM
MES Group, Inc.
550 Norrth Reo Street
Tampa, FL, 33609
813-289-4700
Nicholas Stephenson
1/8" = 1'-0"FX105
1 LEVEL 1 - BUILDING 519 - FIRE PROTECTION
3/8" = 1'-0"FX105
2 LEVEL 1 - BUILDING 519 - ROOM 519A - HAZARD PLAN
3/8" = 1'-0"FX105
3 LEVEL 1 - BUILDING 519 - ROOM 519A - FIRE PROTECTION PLAN
CounterCounter
AREAWAY
VOL. INFO
CENTER
1107C
1107A
1107B
CORRIDOR
1106A
1713E
1713B
1713C
R E
F
RICOH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL - BID
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD
A/E:
STAMPENGINEER OF RECORD
321 4 5 6 7 8 9 10
AESUS DESIGN GROUP
1050 E. Southern Ave., Suite D
Temple, AZ, 85282
480-454-2861
David Combs
EHRM VA LAKE BALDWIN 675-22-701
5201 Raymond St. Orlando, FL 32803
Dec. .22, 2023
Mechanical, Electrical, Plumbing, & Fire Protection
D R e v it L o c a l\ \2
V
A L a k e B a ld w in
E H
R M
M
E P
R
V
O L T
K y le
.M c C u lli n .r v t
/2
/2
:4 :3
P
M
FX401
BLDG 500 FIRST FLOOR ENLARGED
PLANS - HAZARD PLANS
NS ANK/KM
MES Group, Inc.
550 Norrth Reo Street
Tampa, FL, 33609
813-289-4700
Nicholas Stephenson
1/2" = 1'-0"FX401
1 BLDG 500 - LEVEL1 RM 1451A - ZONE 1 TR - HAZARD PLAN
1/2" = 1'-0"FX401
2 BLDG 500 - LEVEL1 ROOM 101A - ZONE 3 TR - HAZARD PLAN
1/4" = 1'-0"FX401
3 BLDG 500 - LEVEL 1 ROOM 1607E - ZONE 2 TR - HAZARD PLAN
1/4" = 1'-0"FX401
4 BLDG 500 - LEVEL1 ROOM 1107A - ZONE 4 TR - HAZARD PLAN
1/4" = 1'-0"FX401
5 BLDG 500 - LEVEL1 ROOM 1713D - ZONE 5 TR - HAZARD PLAN
AREAWAY
VOL. INFO
CENTER
1107C
1107A
1107B
CORRIDOR
1106A
1713E
1713B
1713C
R E
F
RICOH
FIRE PROTECTION SPRINKLER SYSTEM DESIGN CRITERIA
SPACE TYPE
HAZARD
CLASSIFICATION
SYSTEM
TYPE
DISCHARGE
DENSITY
REMOTE
AREA
MAXIMUM
COVERAGE
AREA PER
SPRINKLER
MAXIMUM
SPACING
WATER
SUPPLY
DURATION
OUTSIDE
HOSE
ALLOWANCE
TEMPERATURE
CLASSIFICATION
SPRINKLER TYPE NOTES
GPM/FT² FT² FT² FT. MINUTES GPM
GENERAL,
EXCEPT AS
LISTED BELOW
LIGHT HAZARD WET PIPE 0.10 1,500 225 15 30 100 ORDINARY
SEMI-RECESSED
PENDENT, QUICK
RESPONSE, UL LISTED, FM
APPROVED
STORAGE
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 ORDINARY
SEMI-RECESSED
PENDENT OR UPRIGHT,
QUICK RESPONSE,
UL LISTED, FM APPROVED
EQUIPMENT
ROOM
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 INTERMEDIATE
QUICK RESPONSE
UPRIGHT, UL LISTED, FM
APPROVED
HOUSEKEEPING
CLOSET
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 ORDINARY
PENDENT OR UPRIGHT,
QUICK RESPONSE,
UL LISTED, FM APPROVED
ELEVATOR
EQUIPMENT
ROOM
ORDINARY
HAZARD
GROUP 1
WET PIPE 0.15 1,500 130 15 60-90 250 INTERMEDIATE PER NFPA 13 1
NOTES:
1. WATER DEMAND REQUIREMENTS ARE FOR HYDRAULIC CALCULATION METHOD. IF OTHER METHOD IS USED ADJUST VALUES ACCORDING TO NFPA 13 REQUIREMENTS.
HAZARD
SYMBOL
FIRE PROTECTION NOTES
F1. APPROXIMATE LOCATION OF EXISTING SPRINKLER HEAD. EXISTING SPRINKLER
HEAD TO REMAIN.
F2. APPROXIMATE LOCATION OF EXISTING SPRINKLER HEAD, FIELD COORDINATE
EXACT LOCATION PRIOR TO CONSTRUCTION. RECONFIGURE AND PROVIDE NEW
UPRIGHT SPRINKLER HEADS WITH CAGE AS REQUIRED FOR REVISE BACKGROUNDS
IN TELECOM ROOM
F3. PROVIDE NEW UPRIGHT SPRINKLER HEAD WITH CAGE AS REQUIRED IN TELECOM
ROOM.
F2
F2
F1
F2
F3
F2
F1
F1
F1
F1
F1
F1
F2
F2
F2
F1
F1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL - BID
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD
A/E:
STAMPENGINEER OF RECORD
321 4 5 6 7 8 9 10
AESUS DESIGN GROUP
1050 E. Southern Ave., Suite D
Temple, AZ, 85282
480-454-2861
David Combs
EHRM VA LAKE BALDWIN 675-22-701
5201 Raymond St. Orlando, FL 32803
Dec. .22, 2023
Mechanical, Electrical, Plumbing, & Fire Protection
D R e v it L o c a l\ \2
V
A L a k e B a ld w in
E H
R M
M
E P
R
V
O L T
K y le
.M c C u lli n .r v t
/2
/2
:4 :4
P
M
FX402
BLDG 500 FIRST FLOOR ENLARGED
PLANS - FIRE PROTECTION
NS ANK/KM
MES Group, Inc.
550 Norrth Reo Street
Tampa, FL, 33609
813-289-4700
Nicholas Stephenson
1/2" = 1'-0"FX402
1 BLDG 500 - LEVEL1 RM 1451A - ZONE 1 TR - RENOVATION
1/2" = 1'-0"FX402
2 BLDG 500 - LEVEL1 ROOM 101A - ZONE 3 TR - RENOVATION
1/4" = 1'-0"FX402
3 BLDG 500 - LEVEL 1 ROOM 1607E - ZONE 2 TR - RENOVATION
1/4" = 1'-0"FX402
4 BLDG 500 - LEVEL1 ROOM 1107A - ZONE 4 TR - RENOVATION
1/4" = 1'-0"FX402
5 BLDG 500 - LEVEL1 ROOM 1713D - ZONE 5 TR - RENOVATION
J
XX-1
K
OS
T
TD
D
P
P
J
R
TC
H
T
F
F
F
F
XX-1 XX-1 XX-1
D
F P
FR
CLNG
J
CLNG
F S
D
V
M
ES
ML
DC
CL
CR
MD
E
B
D
S
P
N
TV
N
N
1P 1 POLE (2P, 3P, 4P, ETC.)
A AMPERE
AC ABOVE COUNTER
ACLG ABOVE CEILING
ADO AUTOMATIC DOOR OPENER
AF AMP FRAME
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFI ARC FAULT CIRCUIT
INTERRUPTER
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
AMPL AMPLIFIER
ANNUN ANNUNCIATOR
APPROX APPROXIMATELY
AQ-STAT AQUASTAT
ARCH ARCHITECT, ARCHITECTURAL
AS AMP SWITCH
AT AMP TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AWG AMERICAN WIRE GAUGE
BATT BATTERY
BD BOARD
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
C CONDUIT
CAB CABINET
CAT CATALOG
CATV CABLE TELEVISION
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CLG CEILING
COMB COMBINATION
CMPR COMPRESSOR
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUATION OR CONTINUOUS
CONTR CONTRACTOR
CONV CONVECTOR
CP CIRCULATING PUMP
CRT CATHODE-RAY TUBE
CT CURRENT TRANSFORMER
CTR CENTER
CU COPPER
DCP DOMESTIC WATER CIRCULATING PUMP
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN DOWN
DPR DAMPER
DS SAFETY DISCONNECT SWITCH
DT DOUBLE THROW
DWG DRAWING
EC ELECTRICAL CONTRACTOR
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
ELU EMERGENCY LIGHTING UNIT
EM EMERGENCY
EMS ENERGY MANAGEMENT SYSTEM
EMT ELECTRICAL METALLIC TUBING
EP ELECTRIC PNEUMATIC
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXH EXHAUST
EXP EXPLOSION PROOF
FA FIRE ALARM
FABP FIRE ALARM BOOSTER POWER
SUPPLY PANEL
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FU FUSE
FUDS FUSED SAFETY DISCONNECT SWITCH
GA GAUGE
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GFI GROUND FAULT CIRCUIT INTERRUPTER
GFP GROUND FAULT PROTECTOR
GND GROUND
GRS GALVANIZED RIGID STEEL (CONDUIT)
GYP BD GYPSUM BOARD
HOA HANDS-OFF-AUTOMATIC SWITCH
HORIZ HORIZONTAL
HP HORSEPOWER
HPF HIGH POWER FACTOR
HT HEIGHT
HTG HEATING
HTR HEATER
HV HIGH VOLTAGE
HVAC HEATING, VENTILATING AND AIR
CONDITIONING
IC INTERRUPTING CAPACITY
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
I/W INTERLOCK WITH
J-BOX JUNCTION BOX
KV KILOVOLT
KVA KILOVOLT-AMPERE
KVAR KILOVOLT-AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LOC LOCATE OR LOCATION
LT LIGHT
LTG LIGHTING
LTNG LIGHTNING
LV LOW VOLTAGE
MAX MAXIMUM
MAG.S MAGNETIC STARTER
M/C MOMENTARY CONTACT
MC MECHANICAL CONTRACTOR
ELECTRICAL ABBREVIATIONS LIST ELECTRICAL SYMBOL NOTES
EXIT LIGHTS. STEM INDICATES WALL MOUNTING. NO STEM INDICATES CEILING
MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S). ARROW INDICATES
DIRECTIONAL ARROW ON ILLUMINATED FACE(S). THE CIRCUIT DESIGNATION IS
INDICATED BY A NUMBER. EXAMPLE: THE WALL MOUNTED EXIT LIGHT TYPE "E1"
WITH SINGLE FACE AND DIRECTIONAL ARROW IS CONNECTED TO CIRCUIT 1.
DEVICES. THE CIRCUIT DESIGNATION IS INDICATED BY A NUMBER. THE SWITCH
DESIGNATION IS INDICATED BY A LOWER CASE LETTER. EXAMPLE: SPLIT
DUPLEX RECEPTACLE IS CONNECTED TO CIRCUIT 1 AND ONE RECEPTACLE
OUTLET IS CONTROLLED BY SWITCH "d".
THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE LETTER.
EXAMPLE: SINGLE POLE SWITCH "d" TO CONTROL LIGHTING FIXTURES INDICATED BY "d".
WALL BOX DIMMER WITH SIZE AS INDICATED AT DEVICE. EXAMPLE: 600 WATT
WALL BOX DIMMER TO CONTROL LIGHTING FIXTURES INDICATED BY "e". SEE
SPECIFICATIONS FOR WATTAGE IF NOT INDICATED.
SPECIAL CONNECTIONS. THE EQUIPMENT IS INDICATED BY A NUMBER IN A
CIRCLE. SEE THE MOTOR AND EQUIPMENT SCHEDULE FOR THE LOAD
DESCRIPTION AND TYPE OF CONNECTION. THE CIRCUIT DESIGNATION IS
INDICATED BY NUMBER(S) ADJACENT TO THE SYMBOL. EXAMPLE: EQUIPMENT NO.
ELEC-1; 1 PHASE CONNECTION TO CIRCUITS 2, 4.
MOTOR CONNECTIONS. THE MOTOR IS INDICATED BY A NUMBER WITHIN OR
CHARACTERS ADJACENT TO THE MOTOR SYMBOL. SEE THE MOTOR AND
EQUIPMENT SCHEDULE FOR THE MOTOR DESCRIPTION AND ELECTRICAL
REQUIREMENTS.
TRANSFORMERS. THE TRANSFORMER TYPE IS INDICATED BY A NUMBER
FOLLOWING THE UPPER CASE LETTER "T". SEE THE TRANSFORMER
SCHEDULE OR THE SINGLE LINE DIAGRAM FOR THE TRANSFORMER
DESCRIPTION AND REQUIREMENTS. EXAMPLE: TRANSFORMER TYPE "T1".
PANELBOARDS. PANELBOARD DOORS MAY BE SHOWN TO INDICATE OPENING
SIDE OF RECESSED PANELBOARDS. SEE PANELBOARD IDENTIFICATION FOR
DESIGNATION CODES.
CONDUIT SHOWN WITHOUT SLASH MARKS SHALL CONTAIN 1 # 12 CONDUCTOR
PER PHASE, NEUTRAL, AND GROUND IN 1/2" CONDUIT UNLESS SPECIFIC
EQUIPMENT REQUIRES A DIFFERENT SIZE.
CONDUIT SHOWN SHALL CONTAIN 1 # 10 CONDUCTOR PER PHASE IN ELECTRICAL
CODE SIZED MINIMUM CONDUIT UNLESS A CONDUCTOR AND CONDUIT SIZE IS
SHOWN ADJACENT.
HOME RUN TO BRANCH CIRCUIT PANELBOARD. THE PANELBOARD DESIGNATION
IS SHOWN ADJACENT TO THE HOME RUN ARROW AS A NUMERATOR AND THE
CIRCUIT DESIGNATION IS SHOWN AS THE DENOMINATOR. CIRCUIT BREAKER
SIZES (AMPS/NUMBER OF POLES) ARE SHOWN IN THE PANELBOARD SCHEDULE
WITH THE CORRESPONDING PANELBOARD AND CIRCUIT DESIGNATION.
EXAMPLE: HOME RUN TO PANELBOARD P4N-102; CIRCUITS 1, 3, 5.
SYMBOLSYMBOL SYMBOL
ELECTRICAL SYMBOL LEGEND
DESCRIPTION DESCRIPTION DESCRIPTION
FIRE ALARM HORN W/STROBE
FIRE ALARM BELL
FIRE ALARM BELL W/STROBE
FIRE ALARM CHIME W/STROBE
THERMOSTAT
HUMIDISTAT
TIME CONTROL SWITCH
RELAY
SAFETY DISC. SW. (FUSED)
SAFETY DISC. SW. (NON-FUSED)
COMB. MOTOR STARTER (FUSED)
MOTOR
TRANSFORMER
FLOOR JUNCTION BOX
JUNCTION BOX
UTILITY SERVICE POWER POLE
STATIC GROUND RECEPTACLE
SURGERY SERVICE COLUMN
POWER POLE (OPEN OFFICE STYLE)
MULTIOUTLET ASSEMBLY
RECEPT. ON CORD REEL
FLOOR DUPLEX RECEPT.
240V RECEPTACLE
FOURPLEX RECEPT. ON EMERG. CIRCUIT
FOURPLEX RECEPT.
DUPLEX RECEPT. ON EMERG. CIRCUIT
DUPLEX ISOLATED GROUND RECEPT.
SPLIT DUPLEX RECEPT.
DUPLEX RECEPT.
SINGLE RECEPT.
PUSH BUTTON
TIME DELAY SWITCH
TIMER SWITCH
OCCUPANCY SENSOR W/ MANUAL SWITCH
DIMMER SWITCH
SWITCH W/PILOT
KEYED SWITCH
4-WAY SWITCH
3-WAY SWITCH
SINGLE POLE SWITCH
PS - D2
T1
PANELBOARD IDENTIFICATION
KEYED NOTE (SEE SCHEDULE)
NUMBER OF SHEET WHERE DETAIL APPEARS
NUMBER OF DETAIL ON SHEET
REVISION NUMBER - SHOWN ON PLANS
ROOM NAME AND NUMBER
ITEM TO BE
REMOVED
AREA NOT IN
CONTRACT
XX-1 IDENTITY (SEE SCHEDULE)
XX-1
EXISTING TO REMAIN
XX-1
RELOCATED
XX-1
DEMOLISHED
1d d e
2,4
T1
FLOOR CLEARANCE AREA
CONDUIT IN CEILING, FLOOR OR WALL AS REQUIRED BY FIELD CONDITIONS
CONDUIT IN FLOOR
P4N-102
1. EQUIPMENT DESIGNATION:
L = LIGHTING
P = POWER
D = DISTRIBUTION
S = SWITCHBOARD
M = MOTOR CONTROL CENTER
R = RELAY PANEL
2. VOLTAGE DESIGNATION:
1 = 120/240V - 1PH
2 = 240V - 3PH
3 = 208Y/120V - 3PH
4 = 480Y/277V - 3PH
5 = 120/208 - 1PH
6 = SPECIAL
3. SYSTEM DESIGNATION:
N = NORMAL
E = EMERGENCY
C = POWER CONDITIONED
U = UNINTERRUPTIBLE POWER SOURCE
4. FLOOR DESIGNATION:
B = BASEMENT
G = GROUND
1 = FIRST FLOOR
2 = SECOND FLOOR
ETC.
5. PANEL NO. DESIGNATION:
01 = PANELBOARD #1
02 = PANELBOARD #2
03 = PANELBOARD #3
ETC.
FIRE ALARM PULL STATION
FIRE ALARM DOOR HOLDER
FIRE ALARM DOOR CLOSER
FIRE ALARM SHUT DOWN RELAY
CEILING DATA OUTLET
FLOOR DATA OUTLET
# OF VOICE AND # OF DATA OUTLETS.
FOR EXAMPLE 1V2D = 1 VOICE, 2 DATA
P4N-102 1, 3, 5
#10
#12
EXISTING TO REMAIN
EXISTING TO BE REMOVED
NEW
GRAPHICAL REPRESENTATION OF PHASING, TYPICAL FOR ALL SYMBOLS.
CEILING DUPLEX RECEPT.
CEILING JUNCTION BOX
FLOOR TELEPHONE OUTLET
GFI DUPLEX RECEPT. (FEED THROUGH)
GFI WEATHERPROOF RECEPT.
DUPLEX RECEPT.
(DESIGNATES SPECIFIC MOUNTING HEIGHT)
48"
GFI
GFI
WP
CLNG
ELEC-1
Room
FIRE ALARM SPEAKER W/STROBE
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDC MAIN DISTRIBUTION CENTER
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MFS MAIN FUSED DISCONNECT SW
MH MANHOLE
MIC MICROPHONE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MMS MANUAL MOTOR STARTER
MOA MULTIOUTLET ASSEMBLY
MSP MOTOR STARTER PANELBOARD
MSBD MAIN SWITCHBOARD
MT MOUNT
MT.C EMPTY CONDUIT
MTS MANUAL TRANSFER SWITCH
MTR MOTOR, MOTORIZED
N.C. NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
NFDS NON-FUSED SAFETY DISCONNECT
SWITCH
NIC NOT IN CONTRACT
NL NIGHT LIGHT
N.O. NORMALLY OPEN
NPF NORMAL POWER FACTOR
NTS NOT TO SCALE
OH OVERHEAD
OL OVERLOADS
PA PUBLIC ADDRESS
PB PULL BOX OR PUSHBUTTON
PE PNEUMATIC ELECTRIC
PED PEDESTAL
PF POWER FACTOR
PH PHASE
PIV POST INDICATING VALVE
PNL PANEL
PP POWER POLE
PR PAIR
PRI PRIMARY
PROJ PROJECTION
PRV POWER ROOF VENTILATOR
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE (CONDUIT)
PWR POWER
QUAN QUANTITY
RCPT RECEPTACLE
REQD REQUIRED
RM ROOM
RSC RIGID STEEL CONDUIT
RTU ROOF TOP UNIT
SC SURFACE CONDUIT
SEC SECONDARY
SHT SHEET
SIM SIMILAR
S/N SOLID NEUTRAL
SPEC SPECIFICATION
SPKR SPEAKER
SP SPARE
SR SURFACE RACEWAY
SS STAINLESS STEEL
SSW SELECTOR SWITCH
S/S STOP/START PUSHBUTTONS
STA STATION
STD STANDARD
SURF SURFACE MOUNTED
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
TEL TELEPHONE
TEL/DATA TELEPHONE/DATA
TERM TERMINAL
TL TWIST LOCK
TR TAMPER RESISTANT
T-STAT THERMOSTAT
TTC TELEPHONE TERMINAL CABINET
TV TELEVISION
TVTC TELEVISION TERMINAL CABINET
TYP TYPICAL
UC UNDER COUNTER
UE UNDERGROUND ELECTRICAL
UG UNDERGROUND
UH UNIT HEATER
UT UNDERGROUND TELEPHONE
UTIL UTILITY
UV ULTRAVIOLET
V VOLT
VA VOLT-AMPERES
VDT VIDEO DISPLAY TERMINAL
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W WATT
W/ WITH
WG WIRE GUARD
WH WATER HEATER
W/O WITHOUT
WP WEATHERPROOF
XFMR TRANSFORMER
XFR TRANSFER
∠ ANGLE
@ AT
▲ DELTA
' FEET
" INCHES
# NUMBER
Ø PHASE
C CENTER LINE
P PLATE
EXIT LIGHT, WALL-MOUNTED, SHADING
AND ARROWS INDICATE FACES AND
DIRECTION
WALL-MOUNTED FIXTURES, TYPICAL
EXW1
LIGHTING FIXTURE TAG DESCRIPTORS:
TOP VALUE: FIXTURE TYPE ID.
BOTTOM VALUE, NUMBER: CIRCUIT NUMBER, REFER TO DRAWINGS FOR
PANEL.
BOTTOM VALUE, LOWERCASE LETTER: SWITCH DESIGNATION.
ABSENCE OF A SWITCH ID INDICATES FIXTURE IS CONTROLLED BY THE ONLY
SWITCH IN THE SPACE.
"x" IN PLACE OF THE SWITCH ID INDICATES NIGHT LIGHT, UNSWITCHED.
S3 1d
ELECTRIC STRIKE
MAGNETIC LOCK
COMBINATION LOCK
DOOR CONTACT
CARD READER
SECURITY KEYPAD
MOTION DETECTOR
NURSE CALL EMERG. STATION
NURSE CALL CODE BLUE STATION
NURSE CALL DUTY STATION
NURSE CALL STAFF STATION
NURSE CALL PATIENT STATION
NURSE CALL DOME LIGHT (1-COLOR)
TELEPHONE OUTLET
VOICE/DATA OUTLET
DOOR BELL
DOOR BUZZER
DOOR CHIME
DOOR SIGNAL
VOLUME CONTROL
MICROPHONE OUTLET
1V2D
CATV OUTLET
TV OUTLET
NURSE CALL DOME LIGHT (4-COLORS)
NURSE CALL DOME LIGHT (2-COLORS)
AUTO DOOR PUSH PAD
EMERGENCY LIGHTING UNIT, WALL-
MOUNTED, REMOTE BATTERY
EMERGENCY LIGHTING UNIT, WALL-
MOUNTED, INTEGRAL BATTERY
EMERGENCY LIGHTING UNIT, CEILING-
MOUNTED, INTEGRAL BATTERY
EMERGENCY LIGHTING UNIT, CEILING-
MOUNTED, REMOTE BATTERY
LIGHTING FIXTURES, TYPICAL,
RECTANGULAR
FILLED CIRCLES INDICATE RECESSED,
OPEN CIRCLES INDICATE SURFACE
DIAGONAL LINE INDICATES LENSED
OUTER DOTS INDICATE SUSPENDED
LIGHTING FIXTURES, TYPICAL, ROUND
CENTER DOT INDICATES PENDANT
DIAGONAL LINE INDICATES LENSED
CHEVRON INDICATES WALL WASH
STRIP FIXTURE
DIRECTIONAL LIGHT, TRACK, FLOOD
EXIT LIGHT, CEILING-MOUNTED, SHADING
AND ARROWS INDICATE FACES AND
DIRECTION
LINEAR LIGHT, TAPE LIGHT
EXIT/ELU COMBO
DIAGONAL HATCH INDICATES LIGHT ON A
CRITICAL CIRCUIT
SOLID HATCH INDICATES LIGHT ON AN
EMERGENCY OR LIFE SAFETY CIRCUIT
POLE/AREA LIGHTS
POST-TOP AREA LIGHT
BOLLARD LIGHT
SPRINKLER FLOW SWITCH
SPRINKLER VALVE TAMPER SWITCH
DUCT SMOKE DETECTOR
CEILING SMOKE DETECTOR
THERMAL DETECTOR
L21-20 R RECEPT.
L21-30 R RECEPT.
L5-30 SINGLE-PHASE POWER
WAP ALLOCATION
CABLE LABELING NOTES
CABLE LABELING MATRICES FOR CABLE PLANT AND PATCH CORD
MEDIA SHALL BE PROVIDED BY THE GENERAL CONTRACTOR AS PART
OF THE SHOP DRAWINGS DELIVERABLE WHERE APPLICABLE AS
NOTED ON THE DRAWINGS. THE INSTALLING GENERAL CONTRACTOR
SHALL BE RESPONSIBLE FOR COMPLETING THE LABELING OF THE
CABLE PLANT ON BOTH ENDS. LABELING REQUIREMENTS ARE TIA-606
AS MODIFIED FOR THE VA ENVIRONMENT, WITH DETAILS FOUND IN
SECTION 5, ADMINISTRATION, OF THE ISTS.
EXISTING PHONE LINES NOTES
GENERAL CONTRACTOR SHALL VERIFY ALL PHONE LINES AND WIRING
ARE TO REMAIN FULLY FUNCTIONAL AS VOIP WILL NOT BE IN
OPERATION ONCE DEMOLITION BEGINS.
CONTRACTOR NOTES
THE GENERAL CONTRACTOR SHALL REQUEST THE PROJECT
NARRATIVE AS PART OF THE DESIGN DOCUMENT PACKAGE.
DOCUMENT SHALL BE REVIEWED AND SHALL INCORPORATE ALL THE
DESIGN ASPECTS HEREIN MENTIONED.
THIS PROJECT WILL REQUIRE TO PERFORM WORK ON PARTS OF THE
BUILDING AT TIMES TO MITIGATE THE DISRUPTION THE NORMAL
OPERATIONS. PRIOR BID ISSUANCE, THE GENERAL CONTRACTOR
SHALL REQUEST THE EXPECTED ALLOWABLE WORK PER AREA PER
PERIOD OF TIME TO THE VA. PROJECT BID SHALL ACCOMMODATE THE
WORK TIMES AVAILABLE.
CONTRACTOR SHALL COORDINATE THE SUBMITTALS AND
PROCUREMENT OF MATERIAL IN A TIMELY MANNER. DELAYS CAUSED
BY LONG LEAD ITEMS SHALL BE THE SOLE RESPONSIBILITY OF THE
GENERAL CONTRACTOR.
FOR NEW CONDUIT PENETRATIONS LEADING INTO ROOM 1128, THE
DESIGN INTENT IS TO PROVIDE A 90 DEGREE BEND UNDERGROUND
AND RUN CONDUITS ALONG THE EXTERIOR OF THE BUILDING, THEN
PENETRATING INTO THE ROOM AT A HIGH ELEVATION FOR EASE OF
TRANSITION: UTILIZING CABLE TRAYS TO THE TERMINATION
LOCATION. NO UNDERGROUND/CUTTING OF EXISTING SLAB WITHIN
ROOM 1128 SHALL BE PERFORMED FOR NEW CONDUIT
PENETRATIONS.
THE GENERAL CONTRACTOR SHALL PROVIDE INSTALLATION AND
FABRICATION HARDWARE FOR VERTICAL PDUS TO BE INSTALLED IN 2
POLE RACKS SCHEDULED TO REMAIN.
COORDINATION NOTES
A. PROJECT BID SHALL INCLUDE MAINTAINING FUNCTIONALITY OF ROOM #1128 IN BUILDING 500
WHILE PERFORMING WORK.
B. WHEREVER LUGS ARE REQUIRED FOR WIRE TERMINATIONS, PROVIDE TWO HOLE LUGS IN
LIEU OF ONE HOLE LUGS TO PREVENT LUG ROTATION.
C. SECURITY CAMERAS BEING INSTALLED MUST MEET THE FOLLOWING REQUIREMENTS:
1. 3 MEGA PIXEL RESOLUTION
2. 30 F/S FRAME RATE
3. 30 DAY RECORDING TIME
D. NEW WIRELESS ACCESS POINT DEVICES BEING INSTALLED SHALL BE CAPABLE OF
SUPPORTING NEXT GENERATION SOFTWARE, COMBINING WI-FI AND VIRTUAL BLE (vBLE)
TOGETHER IN A COST-EFFECTIVE CONVERGED PLATFORM.
E. NEW SYSTEMS SERVERS ARE REQUIRED TO BE LOCATED IN ROOM 1128 AS THE BASIS OF BID.
OTHER VIABLE TRS WITH WRITTEN APPROVAL OF THE VA ARE ACCEPTABLE.
ELECTRICAL GENERAL NOTES
A CONDUCTORS OPERATING AT 50 VOLTS OR GREATER SHALL BE IN RACEWAY.
RACEWAY WITHIN THE STRUCTURE ABOVE THE FLOOR SLAB SHALL BE METAL.
RACEWAY BELOW THE FLOOR SLAB AND UNDERGROUND RACEWAY OUTSIDE THE
STRUCTURE SHALL BE PVC.
B LOW VOLTAGE CABLES OR CONDUCTORS OPERATING AT LESS THAN 50 VOLTS SHALL
BE IN METAL RACEWAY WHERE INSTALLED WITHIN WALLS OR INACCESSIBLE SPACES.
LOW VOLTAGE CABLES MAY BE RUN IN CABLE TRAY WHERE NOTED. LOW VOLTAGE
CABLES MAY BE RUN IN CABLE SUPPORT HOOKS ABOVE ACCESSIBLE CEILINGS
WHERE NOTED. LOW VOLTAGE CABLE SHALL BE PLENUM RATED IN PLENUM SPACES.
B LOW VOLTAGE CABLES OR CONDUCTORS OPERATING AT LESS THAN 50 VOLTS SHALL
BE IN METAL RACEWAY. LOW VOLTAGE CABLES MAY BE RUN IN CABLE TRAY WHERE
NOTED. LOW VOLTAGE CABLE SHALL BE PLENUM RATED IN PLENUM SPACES.
C COORDINATE LOCATIONS OF DEVICES WITH ARCHITECTURAL ELEVATIONS AND
DETAILS. ARCHITECTURAL ELEVATIONS AND DETAILS TAKE PRECEDENCE OVER
LOCATIONS SHOWN ON ELECTRICAL DRAWINGS.
D PROVIDE CABLE OR CONDUIT AND WIRE AS REQUIRED TO ACHIEVE CIRCUITING
SHOWN. SIZE CONDUCTORS PER NEC AMPACITY AND WIRE FILL CRITERIA. PROVIDE
DEDICATED NEUTRAL AND GROUND CONDUCTORS FOR CIRCUITING ,UNLESS NOTED
OTHERWISE. INCREASE BRANCH CIRCUIT AND/OR FEEDER CONDUCTORS INCLUDING
EQUIPMENT GROUNDING CONDUCTORS PROPORTIONALLY FOR NO MORE THAN 3%
VOLTAGE DROP ON BRANCH CIRCUITS AND 2% ON FEEDERS PER ENERGY CODE.
E IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE INSTALLATION OF
ELECTRICAL SYSTEMS AND THOSE REQUIRING ELECTRICAL CONNECTIONS TO
MAINTAIN NEC REQUIRED CLEARANCES, INCLUDED BY NOT LIMITED TO AREAS ABOVE
ACCESSIBLE CEILINGS.
F COORDINATE WITH OTHER TRADES FOR PROPER INSTALLATION OF EQUIPMENT.
CONSULT THE DRAWINGS OF OTHER TRADES OR CRAFTS TO AVOID CONFLICTS WITH
EQUIPMENT, ETC. CONFLICTS SHALL BE RESOLVED PRIOR TO ROUGH-IN AND AT NO
ADDITIONAL COST TO THE OWNER.
G LEAVE THE SITE CLEAN AND READY FOR OCCUPANCY. REMOVE DIRT, DEBRIS, EMPTY
CARTONS, TOOLS, CONDUIT AND WIRE SCRAPS AND MISCELLANEOUS SPARE
EQUIPMENT AND MATERIALS USED IN THIS DIVISION OF THE WORK DURING
CONSTRUCTION. COMPONENTS SHALL BE FREE OF DUST, GRIT AND FOREIGN
MATERIALS AND LEFT AS NEW BEFORE FINAL ACCEPTANCE OF WORK.
H THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE
USED IN THIS SET OF DRAWINGS.
I PERFORM WORK TO COMPLY WITH THE STANDARD PRACTICES FOR GOOD
WORKMANSHIP PUBLISHED BY NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION
(NECA). COMPLY WITH THE LATEST ENFORCED EDITION OF THE NATIONAL
ELECTRICAL CODE (NEC), LOCAL CODES, AMENDMENTS, AND ORDINANCES.
J FIELD COORDINATE FINAL MECHANICAL AND EQUIPMENT LOCATIONS ALONG WITH
CONNECTION REQUIREMENTS AND CONTROL WIRING PRIOR TO ROUGH-IN. ADJUST
CORRESPONDING CIRCUIT BREAKER RATINGS AND BRANCH CIRCUITING
ACCORDINGLY.
K ELECTRICAL WORK SHALL BE PERFORMED UNDER THE SUPERVISION OF A LICENSED
MASTER ELECTRICIAN. PROCURE PERMITS AND LICENSES AND PAY FEES
ASSOCIATED WITH THIS WORK.
L MATERIALS FURNISHED FOR THIS PROJECT SHALL BE NEW, COMMERCIAL GRADE,
FREE OF DEFECTS, AND LISTED BY A NATIONALLY RECOGNIZED TESTING
LABORATORY UNO.
M PROVIDE COMPLETE OPERATION & MAINTENANCE MANUAL INCLUDING APPROVED
SUBMITTAL DRAWINGS, WARRANTY INFORMATION FOR PRODUCT SUPPLIED,AND
MANUFACTURES OPERATION AND
MAINTENANCE INSTRUCTIONS.
N THE CONTRACTOR IS RESPONSIBLE FOR MAKING FINAL WIRING TERMINATIONS TO
PRE-INSTALLED RECEPTACLES IN OFFICE FURNITURE. CONTRACTOR IS RESPONSIBLE
FOR WIRING AND INSTALLING VOICE/DATA DEVICES IN OFFICE FURNITURE.
COORDINATE PLACEMENT OF DEVICES WITH FURNITURE LAY-OUT.
O SECURITY SYSTEM TO BE PROVIDED UNDER SEPARATE CONTRACT. IT IS THE
RESPONSIBILITY OF THIS CONTRACTOR TO PROVIDE CONDUIT PROVISIONS, BACK
BOXES, ROUGH-INS, SLEEVES AND POWER TO HEAD END EQUIPMENT FOR EXACT
REQUIREMENTS PRIOR TO START OF WORK.
P CONDUIT AND WIRE SHALL NOT BE INSTALLED BELOW FLOOR SLAB UNLESS
INDICATED ON PLAN BY DASHED CONDUIT.
Q CONTRACTOR SHALL BE RESPONSIBLE FOR WIRING ELECTRICAL ITEMS SHOWN ON
DRAWINGS EXCEPT FOR ITEMS LISTED IN NOTE 'R' BELOW.
R TV OUTLETS, VOLUME CONTROLS, NURSE CALL DOME LIGHTS, NURSE CALL DEVICES,
TELEPHONE OUTLETS, DATA OUTLETS, AND FIRE ALARM DEVICES SHALL CONSIST OF
A BACK BOX WTIH CONDUIT STUBBED ABOVE THE ACCESSIBLE CEILING, SEE STUB UP
DETAIL.VERIFY SIZE OF BACK BOX REQUIRED WITH DEVICE TO BE INSTALLED. LOCATE
BACK BOXES 6" FROM ADJACENT POWER RECEPTACLE INTENDED FOR COMPUTER
USE.
S FURNISH AND INSTALL CONDUIT FROM BACK BOXES FOR THE FOLLOWING DEVICES
INTO THE ACCESSIBLE CEILING SPACE IN THE CORRIDOR, UNLESS NOTED
OTHERWISE:
1/2"C TV OUTLETS
1/2"C VOLUME CONTROLS
1/2"C DOOR SECURITY DEVICES (CARD READERS, DOOR STRIKES ETC..)
1/2"C NURSE CALL DOME LIGHTS
3/4"C NURSE CALL DEVICES
3/4"C TELEPHONE OUTLETS
3/4"C INFORMATION OUTLETS
3/4"C FIRE ALARM DEVICES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Final - Bid Documents
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD
A/E:
STAMPENGINEER OF RECORD
321 4 5 6 7 8 9 10
Aesus Design Group
1050 E. Southern Ave., Suite D
Temple, AZ, 85282
480-454-2861
David Combs
VA Lake Baldwin EHRM Infrastructure Upgrades
675-22-701
13800 Veterans Way, Orlando, Florida, 32827
Dec. .22, 2023
Mechanical, Electrical, Plumbing, & Fire Protection
C R e v it L o c a l\
\2
V
A L a k e B a ld w in
E H
R M
M
E P
R
V
O L T s a ry
.c h h o e u n g .r v t
/2 /2
:1
:4
A M
E0000
ELECTRICAL NOTES, LEGEND AND
ABBREVIATIONS
JAR BS
MES Group, Inc.
550 Norrth Reo Street
Tampa, FL, 33609
813-289-4700
INDEX OF ELECTRICAL DRAWINGS
E0000 ELECTRICAL NOTES, LEGEND AND ABBREVIATIONS
E001 ELECTRICAL SITE OVERALL PLAN
ES100 FIBER DISTRIBUTION SITE PLAN
ET100 BLDG 500 - LEVEL 1 OVERALL PLANS
ET100A BUILDING 500 - BUILDING FIBER BACKBONE
ET100B BUILDING 500 - LEVEL 1 - CABLE TRAY
ET101 BUILDING 500 - LEVEL 1 - REVISED TELECOM ROOMS PLANS
ET102 BLDG 500 - L1 - EXIST. AND NEW DATA, FIBER DISTRIBUTION NW
ET103 BLDG 500 - L1 - EXIST. AND NEW DATA, FIBER DISTRIBUTION NW
ET104 BLDG 500 - L1 - EXIST. AND NEW DATA, FIBER DISTRIBUTION SW
ET105 BLDG 500 - L1 - EXIST. AND NEW DATA, FIBER DISTRIBUTION NE
ET106 BLDG 500 - L1 - EXIST. AND NEW DATA , FIBER DISTRIBUTION NE
ET107 BLDG 500 - L1 - EXIST. AND NEW DATA, AND FIBER DISTRIBUTION SE
ET108 BLDG 500 - L1 - EXIST. AND NEW DATA, FIBER DISTRIBUTION SE
ET109 BLDG 500 - L1 - DIAMOND DIAGRAM
ET110 BLDG 500 - L2 - EXIST. AND UPDATED TEL. ROOMS PLANS
ET111 BLDG 500 - L2 - DATA AND FIBER DISTRIBUTION
ET112 BLDG 500 - L3 - EXIST. TELECOM ROOMS
ET113 BLDG 500 - L3 - DATA AND FIBER DISTRIBUTION
ET114 BLDG 500 - L4 - EXIST. TELECOM ROOMS
ET115 BLDG 500 - L4 - DATA AND FIBER DISTRIBUTION
ET200 BLDG 501 - EXISTING TELECOM ROOMS
ET201 BLDG 501 - DATA AND FIBER DISTRIBUTION
ET300 BLDG 502 - EXIST. AND UPDATED TELECOM ROOMS PLANS
ET301 BLDG 502 - DATA AND FIBER DISTRIBUTION
ET400 BLDG 504 - EXIST. AND UPDATED TELECOM ROOMS PLANS
ET401 BLDG 504 - DATA AND FIBER DISTRIBUTION
ET500 BLDG 505,506,507,508 - EXIST. AND UPDATED TELECOM ROOMS
ET501 BLDG 505,506,507,508 - DATA AND FIBER DISTRIBUTION
ET600 BLDG 519,521,510,517 - EXIST. AND UPDATED TELECOM ROOMS
ET601 BLDG 519,521,510,517 - DATA AND FIBER DISTRIBUTION
ET602 BLDG 519 - L3 - EXIST. AND UPDATED TLECOM ROOMS PLANS
ET603 BLDG 519,519A,521 - L3 - DATA DROP AND FIBER DISTRIBUTION
ET700 BLDG 3128,3129,3130,3132 - EXIST. AND UPDATED TELECOM ROOMS
ET701 BLDG 3128,3129,3130,3132 - DATA AND FIBER DISTRIBUTION
ET800 BLDG 3133,3134 - EXIST. AND UPDATED TELEC. ROOMS PLANS
ET801 BLDG 3133,3134 - DATA AND FIBER DISTRIBUTION
ET900 FIBER BACKBONE SCHEMATIC
ET901A BLDG 3126, 3136 - DATA AND FIBER DISTRIBUTION
ET901B BLDG 3126, 3136 - EXIST. AND UPDATED TELEC.ROOMS PLANS
EL101 BLDG 500 - LEVEL 1 - ELECTRICAL CABLE TRAYS AND LIGHTING
EL400 BLDG 504 - CABLE TRAY AND LIGHTING
EL500 BLDG 505,506,507,508 - CABLE TRAYS AND LIGHTING
EL600 BLDG 519 - ELECTRICAL CABLE TRAY AND LIGHTING
EP100 BUILDING 500 - LEVEL 1 - POWER
EP101 BUILDING 500 - LEVEL 2 - POWER
EP102 BUILDING 500 - LEVEL 3 - POWER
EP103 BUILDING 500 - LEVEL 4 - POWER
EP104 BUILDING 500 - ELECTRICAL MEZANNINE
EP200 BUILDING 501 - POWER
EP300 BUILDING 502 - POWER
EP400 BUILDING 504 - POWER
EP500 BUILDING 505,506,507,508 - POWER
EP600 BUILDING 519, 510, 517 - POWER
EP700 BUILDING 3128, 3129, 3130, 3132 - POWER
EP800 BUILDING 3133, 3134 - POWER
E600 ELECTRICAL DETAILS
E601 EXISTING AND REVISED RACK ELEVATIONS - DETAILS
E602 EXISTING AND REVISED RACK ELEVATIONS - DETAILS
E603 TYPICAL TR AND TE GROUNDING DETAILS
E604 UNDERGROUND FIBER AND ELECTRICAL DUCTBANK DETAILS
E605 TYPICAL RACK CHARACTERISTICS DETAILS
E606 ELECTRICAL LIGHTING DETAIL
E607 PRELIMINARY GROUNDING RISER DIAGRAM
E701 ONE-LINE DIAGRAM - MV DISTRIBUTION SYSTEM
E702 ONE-LINE DIAGRAM - 501-L1, 502-SWBD1, 513-MDP
E703 ONE-LINE DIAGRAM - 506-ADMIN-P3, 507-ADMIN-P2
E704 ONE-LINE DIAGRAM - 500-SWBD-3-EM, 500-SWBD-3
E706 ONE-LINE DIAGRAM-500-SWBD-2 AND 500 SWBD-4 CONTINUED
E707 REVISED ONE LINE DIAGRAM
E708 REVISED RISER FOR BUILDING 500 1ST FLOOR TRs
E803 PANEL SCHEDULES OF BLDG 500 1ST FLOOR PANELS
E804 PANEL SCHEDULES OF BLDG 500 2ND, 3RD AND 4TH FLOOR
E805 NEW PANEL SCHEDULES FEEDING EMERGENCY TRs OF DIFF BLDGS
E806 PANEL SCHEDULES 1
E807 PANEL SCHEDULES 2
E808 PANEL SCHEDULES 3
RENOVATION GENERAL NOTES
A IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY
EXISTING CONDITIONS AND LAYOUTS. THE CONTRACTOR SHALL
CONTACT ENGINEER OF RECORD WITH ANY DISCREPANCIES. EXISTING
EQUIPMENT AND DEVICE LOCATIONS SHALL BE FIELD VERIFY. REPORT
ANY DISCREPANCIES WITH ENGINEER OF RECORD.
B ALL DEMOLISHED EQUIPMENT SHALL BE PRESENTED TO VA FOR FIRST RIGHT OF REFUSAL.
C CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING ALL OPENINGS IN
EXISTING CONSTRUCTION AFTER REMOVAL OF EQUIPMENT AND
ELECTRICAL DEVICES.
D PROVIDE BLANK COVER PLATES WHERE DEVICES ARE BEING REMOVE
FROM EXISTING WALLS TO REMAIN.
E FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO
BEGINNING WORK AND OBTAIN CLARIFICATION FROM
ARCHITECT/ENGINEER.
F ALL CIRCUITING ASSOCIATED WITH EXISTING POWER DEVICES SHOWN
TO BE REMOVED SHALL REMAIN AND PREPARED FOR RE-CONNECTION
AND EXTENSION AS NECESSARY DURING DEMOLITION.
G PROVIDE WIRE CONDUIT, JUNCTION BOXES, ETC AS REQUIRED TO
MAINTAIN CONTINUITY TO EXISTING TO REMAIN EQUIPMENT, DEVICES
ETC.
H FOR AREAS AND EQUIPMENT WITHIN THE SCOPE OF WORK,
ELECTRICAL EQUIPMENT SHALL BE LOCATED SO THAT THE
CODE REQUIRED MINIMUM WORKING CLEARANCE AND
DEDICATED ELECTRICAL SPACE ARE MAINTAINED
I ELECTRICAL DRAWINGS ARE DIAGRAMMATIC/SCHEMATIC IN
NATURE AND REPRESENT THE GENERAL SCOPE OF WORK. IT IS
NOT WITHIN THE SCOPE OF THE ELECTRICAL DRAWINGS TO
SHOW ALL NECESSARY RACEWAY ROUTING, BENDS, OFFSETS,
PULL BOXES AND OBSTRUCTIONS. CONTRACTOR SHALL
COORDINATE THE FINAL LOCATION OF EQUIPMENT FOR
PROPER OPERATION IN ACCORDANCE WITH CODE, OWNER AND
MANUFACTURER RECOMMENDATIONS
J FINAL MOUNTING HEIGHTS AND LOCATION OF RECEPTACLES
AND DATA CONNECTIONS SHALL BE VERIFIED WITH THE
ARCHITECT AND OWNER PRIOR TO ROUGH-IN.
K COORDINATE FINAL POWER REQUIREMENTS OF ALL
EQUIPMENT IN THE BUILDING WITH VENDOR AND OWNER PRIOR
TO ROUGH-IN.
L ALL NEW WIRING SHALL BE #12 AWG IN 3/4 INCH CONDUIT
UNLESS OTHERWISE NOTED.
DEMOLITION GENERAL NOTES
A EXISTING CONDITIONS ARE BASED ON RECORD DOCUMENTS AND FIELD OBSERVATION. NOTIFY ENGINEER OF ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND EXISTING CONDITIONS PRIOR TO DISTURBING EXISTING
INSTALLATION.
B ALL SERVICE INTERRUPTIONS TO THIS EXISTING FACILITY MUST BE SCHEDULED AT LEAST 3 WEEKS IN ADVANCE AND BE KEPT TO A MINIMUM. COORDINATE ALL DISRUPTIVE WORK AND OUTAGE REQUIREMENTS WITH THE VA/COR.
C REMOVE EXISTING ELECTRICAL DEVICES, EQUIPMENT, BRANCH CIRCUITS AND FEEDERS THAT ARE INDICATED FOR DEMOLITION IN THEIR ENTIRETY BACK TO POINT OF ORIGIN UNLESS OTHERWISE INDICATED. TURN OFF AND LABEL
CIRCUIT BREAKERS AS SPARES FOR NEW WORK WHERE APPLICABLE.
D FOR EQUIPMENT WITHIN THE SCOPE OF THIS REMODEL, VERIFY CONDITION AND AGE OF EXISTING REUSED ELECTRICAL EQUIPMENT CIRCUIT BREAKERS, FUSES, CONDUIT, SWITCHES AND RELATED WIRING. NOTIFY ENGINEER OF ANY
ELECTRICAL AND WIRING AGED BEYOND ITS USEFUL LIFE AND REPLACE AS DIRECTED.
E ELECTRICAL DRAWINGS ARE DIAGRAMMATIC/SCHEMATIC IN NATURE AND REPRESENT THE GENERAL SCOPE OF WORK.
IT IS NOT WITHIN THE SCOPE OF THE ELECTRICAL DRAWINGS TO SHOW ALL NECESSARY RACEWAY ROUTING, BENDS, OFFSETS, PULL BOXES AND OBSTRUCTIONS. CONTRACTOR SHALL COORDINATE THE FINAL LOCATION OF EQUIPMENT FOR PROPER OPERATION IN ACCORDANCE WITH CODE, VA AND MANUFACTURER RECOMMENDATIONS.
F ELECTRICAL CONTRACTOR SHALL REVIEW OTHER DISCIPLINES DRAWINGS AND SHALL DISCONNECT AND MAKE SAFE
FOR REMOVAL OF ALL EQUIPMENT SHOWN TO BE DEMOLISHED.
G DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE OVERCURRENT PROTECTIVE DEVICE. COMPLETELY
REMOVE ALL ABANDONED WIRING.
H MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS PASSING THROUGH AREAS AND
SERVICING UNDISTURBED AREAS.
I ALL FIRE ALARM DEVICES IN AREAS THAT ARE EXISTING TO REMAIN SHALL REMAIN OPERATIONAL DURING
CONSTRUCTION.
J ALL DEMOLISHED EQUIPMENT SHALL BE PRESENTED TO VA FOR FIRST RIGHT OF REFUSAL.
K EQUIPMENT LABELED AS (E) IS EXISTING TO REMAIN.
L EQUIPMENT LABELED AS (R) SHALL BE RELOCATED
M EQUIPMENT LABELED AS (D) SHALL BE DEMOLISHED.
N PROJECT BID SHALL INCLUDE MAINTAINING FUNCTIONALLITY OF EXISTING SERVICES AND UTILITIES IN ALL AREAS BEING
MODIFIED.
O DURING PRE-BID WALK THRU, CONTRACTOR SHALL IDENTIFY EXISTING ITEMS TO BE REUSED OR REINSTALLED AND
MAINTAIN FUNCTIONALLITY OF ALL SYSTEMS.
Revisions: Date:
Title Sheet Revision
Project Title
EHRM VA LAKE BALDWIN
Location
5201 Raymond St. Orlando, FL 32803
L F
BRICK
BRICK
D
IR
T
R O A D
D
IR
T
R O A D
DIRT
ROAD
D
IR
T
D
IR
T
D
IR
T
D
IR
T
D
IR
T
S
IG
N
S
IG
N
S
IG
N
A S P H A L T
F L U M E
A S P H A L T
F L U M E
.3
.7
.3
.1
.8
.3
.3
.5
.7
GENERAL NOTES
A. SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR
PHASES OF DEMOLITION AND CONSTRUCTION. COORDINATE WITH
GENERAL CONTRACTOR.
B. FURNISH AND INSTALL CONDUIT AND WIRE AS NECESSARY FOR
CONTINUITY OF ANY FEEDERS OR BRANCH CIRCUITS
ORIGINATING OUTSIDE THE DEMOLITION AREA THAT SERVES ANY
ELECTRICAL EQUIPMENT OR DEVICES TO REMAIN AFTER
DEMOLITION. MODIFY OR REPLACE AS REQUIRED.
C. FURNISH AND INSTALL CONDUIT AND/OR COMMUNICATIONS/DATA
WIRING AS NECESSARY FOR CONTINUITY OF ANY WIRING
ORIGINATING OUTSIDE THE DEMOLITION AREA THAT SERVES ANY
COMMUNICATIONS/DATA EQUIPMENT OR DEVICES TO REMAIN
AFTER DEMOLITION. MODIFY OR REPLACE AS REQUIRED.
D. CONTRACTOR SHALL ENSURE AT EXTERIOR OF EACH BUILDING
WITHIN SCOPE OF WORK, ALL PBX EQUIPMENT (ANALOG PHONE
PUNCH BLOCK AND PATH PANELS) ARE TO REMAIN IN PLACE.
PROTECT DURING DEMOLITION. THE DESIGN INTENT IS TO
REMOVE FIBER, CAT CABLE AND SWITCHES (IN SUMMARY) ARE
THE ONLY EQUIPMENT, DEVICES AND CABLES TO BE REMOVED
FROM OLDER SPACES.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Final - Bid Documents
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD
A/E:
STAMPENGINEER OF RECORD
321 4 5 6 7 8 9 10
Aesus Design Group
1050 E. Southern Ave., Suite D
Temple, AZ, 85282
480-454-2861
David Combs
VA Lake Baldwin EHRM Infrastructure Upgrades
675-22-701