This document provides details for a federal contract opportunity for construction services. The solicitation number is 36C77622R0019 and seeks support for EHRM Training and Admin Space construction at the Minneapolis Veterans Affairs Medical Center. The Department of Veterans Affairs Technology Acquisition Center in Austin is the contracting agency. The opportunity involves construction and design-build services to support training and administrative spaces at the Minneapolis VAMC facility. Responses are due based on the solicitation timeline. Key services required include construction and design-build support for the EHRM and administrative areas at the medical center located in Minneapolis.
View the file
Other files for this federal contract opportunity
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEVEL 2
18' - 8"
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
4' - 9 1/2" 4' - 9 1/2"
4'
- 2
/4
1 P-2
P-5
VB-1
LEVEL 2
18' - 8"
F3055
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
F0300
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
F0300M1801
F0701
F0295
F3055
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
F0295
F0701
M1801
BOTTOM OF CEILING 9' - 0"
4'
- 2
/4
4' - 9" 4' - 9"
P-2
VB-1
P-5 1
LEVEL 2
18' - 8"
F3055
F0300
F0701 M1801
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
F0300
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
F3200
LEVEL 2
18' - 8"
F3055 M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
F0300
M1801
F0295
F0701
BOTTOM OF CEILING 9' - 0"
5' - 7 1/4" 5' - 7 1/4"
4'
- 2
/4
P-2
VB-1
WP-5
P-2
P-2
WP-6
LEVEL 2
18' - 8"
F3055
F0300
F0701
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
P-1
P-1
VB-1
LEVEL 2
18' - 8"
M1801
F0701
F0300
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
F3055
BOTTOM OF CEILING 9' - 0"
P-5
P-1
P-2
WP-6
VB-1
P-1
LEVEL 2
18' - 8"
F3055
F0295
M1801
F0701
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
M1801
F0701
F0300
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
F3055
F0300
F0701
M1801
F0295
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
4' - 8 3/4"4' - 8 3/4"
1 P-2 P-5
VB-1
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. VA CONTRACT NO.
AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ 70-129AREAG70-131AREAH AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ70-129AREAG70-131AREAH
C U s e rs \l h o ff m a n
\D o c u m e n ts
\6
A rc h (C e n tr a l2 lh o ff m a n N
X Y
V .r v t
/1
/2
:2
:1
P
M
09/07/2021
ARCHITECTURAL - INTERIOR ELEVATIONS EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A416
ISSUE FOR BID
18-11636C26319D0022
1/4" = 1'-0"
Training 3 - East 1/4" = 1'-0"
Training 3 - North
1/4" = 1'-0"
Training 3 - West 1/4" = 1'-0"
Training 3 - South
1/4" = 1'-0"
Training 4 - East 1/4" = 1'-0"
Training 4 - North
1/4" = 1'-0"
Training 4 - West 1/4" = 1'-0"
Training 4 - South
1/4" = 1'-0"
Training 5 - East 1/4" = 1'-0"
Training 5 - North
1/4" = 1'-0"
Training 5 - West 1/4" = 1'-0"
Training 5 - South
1/4" = 1'-0"
Training 6 - East 1/4" = 1'-0"
Training 6 - North
1/4" = 1'-0"
Training 6 - West 1/4" = 1'-0"
Training 6 - South
1. REFER TO SHEETS 1384-A001 & 1384-A002 FOR GENERAL NOTES AND MOUNTING HEIGHT
INFORMATION.
2. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION, PLUMBING, ELECTRICAL, MECHANICAL AND STRUCTURAL DRWAINGS FOR FULL SCOPE OF WORK.
3. REFER TO SHEETS 1384-A102 & 1384-A501 FOR PARITITION TYPES AND LOCATIONS.
GENERAL SHEET NOTES
1 ACOUSTICAL WALL PANEL REFER TO DETAIL
KEYNOTES
Revisions: Date:
65% Design Development Submittal 07/15/2021
95% Construction Documents Submittal 08/19/2021
ISSUE FOR BID 09/07/2021
F0300
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
1P-2
WP-5
WP-5
P-2
VB-1
P-5
5' - 6 1/4" 5' - 6 1/4"
4'
- 2
/4
LEVEL 2
18' - 8"
F3055
F0300
F0701 M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
M1801
F0701
F0300
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
F3200
LEVEL 2
18' - 8"
F3055
BOTTOM OF CEILING 9' - 0"
P-1
P-2
WP-6
VB-1
LEVEL 2
18' - 8"
M0506
F0220
F0600
F0755
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
M0506
F0600
F0220
BOTTOM OF CEILING 9' - 0"
P-1
P-5
VB-1
1384-A304
LEVEL 2
18' - 8"
F0755
F0220
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
F0600
F0220 F0600
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
M1801
F0701
F0300
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
F3055
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
P-1
P-2
WP-5
VB-1
LEVEL 2
18' - 8"
F0295
F0701
M1801
BOTTOM OF CEILING 9' - 0"
P-2P-5
VB-1
WP-6
P-2
4' - 2" 4' - 5 1/4"
4'
- 2
/4
LEVEL 2
18' - 8"
F3055
M1801
F0701
F0295
F0300
BOTTOM OF CEILING 9' - 0"
P-1
VB-2
LEVEL 2
18' - 8"
F0300
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
F3200
LEVEL 2
18' - 8"
F3055
F0300
M1801 F0701F0295
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"4' - 5 1/4" 4' - 2"
4'
- 2
/4
P-2 P-5
WP-6
P-2
VB-1
LEVEL 2
18' - 8"
F3055
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. VA CONTRACT NO.
AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ 70-129AREAG70-131AREAH AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ70-129AREAG70-131AREAH
C U s e rs \l h o ff m a n
\D o c u m e n ts
\6
A rc h (C e n tr a l2 lh o ff m a n N
X Y
V .r v t
/1
/2
:2
:5
P
M
09/07/2021
ARCHITECTURAL - INTERIOR ELEVATIONS EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A417
ISSUE FOR BID
18-11636C26319D0022
1/4" = 1'-0"
Training 7 - East 1/4" = 1'-0"
Training 7 - North
1/4" = 1'-0"
Training 7 - West 1/4" = 1'-0"
Training 7 - South
1/4" = 1'-0"
Conference Room - East 1/4" = 1'-0"
Conference Room - North
1/4" = 1'-0"
Conference Room - West 1/4" = 1'-0"
Conference Room - South
1/4" = 1'-0"
Training 9 - East 1/4" = 1'-0"
Training 9 - North
1/4" = 1'-0"
Training 9 - West 1/4" = 1'-0"
Training 9 - South
1/4" = 1'-0"
Training 10 - East N
1/4" = 1'-0"
Training 10 - North 1/4" = 1'-0"
Training 10 - West
1/4" = 1'-0"
Training 10 - South
1. REFER TO SHEETS 1384-A001 & 1384-A002 FOR GENERAL NOTES AND MOUNTING HEIGHT
INFORMATION.
2. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION, PLUMBING, ELECTRICAL, MECHANICAL AND STRUCTURAL DRWAINGS FOR FULL SCOPE OF WORK.
3. REFER TO SHEETS 1384-A102 & 1384-A501 FOR PARITITION TYPES AND LOCATIONS.
GENERAL SHEET NOTES
1 ACOUSTICAL WALL PANEL REFER TO DETAIL
KEYNOTES
Revisions: Date:
65% Design Development Submittal 07/15/2021
F0300
M1801
F0701
F0295
M1801
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
F3055 M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
F0295
F0701
M1801
BOTTOM OF CEILING 9' - 0"
P-5
4'
- 2
/4
6' - 0 1/4" 6' - 0 1/4"
P-2 1
VB-1
LEVEL 2
18' - 8"
F3055
F0300 M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
F0300 F0701
M1801
BOTTOM OF CEILING 9' - 0"
P-1
P-1
WP-5
VB-1
LEVEL 2
18' - 8"
F0295
M1801 F0701
F3055
F0300
BOTTOM OF CEILING 9' - 0"
4' - 1" 4' - 0 1/4"
4'
- 2
/4
P-2
WP-5
VB-1
P-2
WP-6
WP-5
P-1
LEVEL 2
18' - 8"
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
OP-1
P-2
WP-6
VB-1
LEVEL 2
18' - 8"
M1801
F0701
F0295
F3055
BOTTOM OF CEILING 9' - 0"
P-1P-5
VB-1
LEVEL 2
18' - 8"
M1801 F0295
F0701
BOTTOM OF CEILING 9' - 0"
P-2
VB-1
OP-1
LEVEL 2
18' - 8"
M1801
F0701
F0295
BOTTOM OF CEILING 9' - 0"
4'
- 2
/4
3' - 4" 3' - 4"
P-2WP-5 WP-5
P-1
VB-1
LEVEL 2
18' - 8"
F0295
F0701
M1801
BOTTOM OF CEILING 9' - 0"
VB-1
P-2OP-1
LEVEL 2
18' - 8"
F0300
F0295
F0701
M1801
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
M1801
F0701
F0295
OP-1
P-2
VB-1
LEVEL 2
18' - 8"
BOTTOM OF CEILING 9' - 0"3' - 11 3/4" 3' - 11 3/4"
4'
- 2
/4
P-1
WP-5
WP-6
P-2
P-2
VB-1
WP-5
LEVEL 2
18' - 8"
BOTTOM OF CEILING 9' - 0"
M1801
F0701F0295
P-1
P-2
WP-6
P-1 P-2
WP-5
VB-1
LEVEL 2
18' - 8"
F3055
F0300
F0295
F0701
M1801
BOTTOM OF CEILING 9' - 0"
P-1
P-5
VB-1
WP-6
P-1
P-2
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. VA CONTRACT NO.
AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ 70-129AREAG70-131AREAH AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ70-129AREAG70-131AREAH
C U s e rs \l h o ff m a n
\D o c u m e n ts
\6
A rc h (C e n tr a l2 lh o ff m a n N
X Y
V .r v t
/1
/2
:2
:2
P
M
09/07/2021
ARCHITECTURAL - INTERIOR ELEVATIONS EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A418
ISSUE FOR BID
18-11636C26319D0022
1/4" = 1'-0"
Training 11 - East 1/4" = 1'-0"
Training 11 - North
1/4" = 1'-0"
Training 11 - West 1/4" = 1'-0"
Training 11 - South
1/4" = 1'-0"
Training 12 - East 1/4" = 1'-0"
Training 12 - North
1/4" = 1'-0"
Training 12 - West 1/4" = 1'-0"
Training 12 - South
1. REFER TO SHEETS 1384-A001 & 1384-A002 FOR GENERAL NOTES AND MOUNTING HEIGHT
INFORMATION.
2. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION, PLUMBING, ELECTRICAL, MECHANICAL AND STRUCTURAL DRWAINGS FOR FULL SCOPE OF WORK.
3. REFER TO SHEETS 1384-A102 & 1384-A501 FOR PARITITION TYPES AND LOCATIONS.
GENERAL SHEET NOTES
1/4" = 1'-0"
Training 13 - East 1/4" = 1'-0"
Training 13 - North
1/4" = 1'-0"
Training 13 - West 1/4" = 1'-0"
Training 13 - South
1/4" = 1'-0"
Training 14 - East 1/4" = 1'-0"
Training 14 - North
1/4" = 1'-0"
Training 14 - West 1/4" = 1'-0"
Training 14 - South
1 ACOUSTICAL WALL PANEL REFER TO DETAIL
KEYNOTES
Revisions: Date:
65% Design Development Submittal 07/15/2021
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
BOTTOM OF CEILING 9' - 0"
P-1
P-5
VB-1
LEVEL 2
18' - 8"
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
BOTTOM OF CEILING 9' - 0"
P-1
P-5
VB-1
LEVEL 2
18' - 8"
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2 INTERSTITIAL
28' - 11 1/2"
LEVEL 2
18' - 8"
BTM OF DECKING
34' - 11 1/2"
P-1
VB-1
LEVEL 2 INTERSTITIAL
28' - 11 1/2"
LEVEL 2
18' - 8"
BTM OF DECKING
34' - 11 1/2"
P-1
VB-1
LEVEL 2 INTERSTITIAL
28' - 11 1/2"
LEVEL 2
18' - 8"
BTM OF DECKING
34' - 11 1/2"
P-1
VB-1
LEVEL 2 INTERSTITIAL
28' - 11 1/2"
LEVEL 2
18' - 8"
BTM OF DECKING
34' - 11 1/2"
P-1
P-5
VB-1
LEVEL 2 INTERSTITIAL
28' - 11 1/2"
LEVEL 2
18' - 8"
BTM OF DECKING
34' - 11 1/2"
WP-9
VB-1
4'
- 0
P-1
LEVEL 2 INTERSTITIAL
28' - 11 1/2"
LEVEL 2
18' - 8"
BTM OF DECKING
34' - 11 1/2"
P-1
WP-9
P-5
4'
- 0
LEVEL 2 INTERSTITIAL
28' - 11 1/2"
LEVEL 2
18' - 8"
BTM OF DECKING
34' - 11 1/2"
P-1
WP-9
VB-1
4'
- 0
LEVEL 2 INTERSTITIAL
28' - 11 1/2"
LEVEL 2
18' - 8"
BTM OF DECKING
34' - 11 1/2"
WP-9
P-1
VB-1
4'
- 0
LEVEL 2
18' - 8"
2'
- 1
0"
K1552K4665 U0225
BOTTOM OF CEILING 9' - 0"
3'
- 4
P-1
SS-1
VB-1
PL-1
SS-1
PL-1
LEVEL 2
18' - 8"
U0225
F0740
F0295
BOTTOM OF CEILING 9' - 0"
P-1
P-5
VB-1
LEVEL 2
18' - 8"
R7250
F0295
F0740
BOTTOM OF CEILING 9' - 0"
P-1
VB-1
LEVEL 2
18' - 8"
2'
- 1
0"
R7250
K4665 K1552
BOTTOM OF CEILING 9' - 0"
VB-1
P-1PL-1
SS-1
PL-1
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. VA CONTRACT NO.
AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ 70-129AREAG70-131AREAH AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ70-129AREAG70-131AREAH
C U s e rs \l h o ff m a n
\D o c u m e n ts
\6
A rc h (C e n tr a l2 lh o ff m a n N
X Y
V .r v t
/1
/2
:2
:1
P
M
09/07/2021
ARCHITECTURAL - INTERIOR ELEVATIONS EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A419
ISSUE FOR BID
18-11636C26319D0022
1. REFER TO SHEETS 1384-A001 & 1384-A002 FOR GENERAL NOTES AND MOUNTING HEIGHT
INFORMATION.
2. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION, PLUMBING, ELECTRICAL, MECHANICAL AND STRUCTURAL DRWAINGS FOR FULL SCOPE OF WORK.
3. REFER TO SHEETS 1384-A102 & 1384-A501 FOR PARITITION TYPES AND LOCATIONS.
GENERAL SHEET NOTES
1/4" = 1'-0"
Storage 147 - East 1/4" = 1'-0"
Storage 147 - North
1/4" = 1'-0"
Storage 147 - West 1/4" = 1'-0"
Storage 147 - South
1/4" = 1'-0"
Storage 149 - East 1/4" = 1'-0"
Storage 149 - North
1/4" = 1'-0"
Storage 149 - West 1/4" = 1'-0"
Storage 149 - South
1/4" = 1'-0"
Roof Access - East 1/4" = 1'-0"
Roof Access - South
1/4" = 1'-0"
Roof Access - West 1/4" = 1'-0"
Roof Access-North
1/4" = 1'-0"
HAC - East 1/4" = 1'-0"
HAC - North
1/4" = 1'-0"
HAC - West 1/4" = 1'-0"
HAC - South
1/4" = 1'-0"
Break Room - East 1/4" = 1'-0"
Break Room - North
1/4" = 1'-0"
Break Room - West 1/4" = 1'-0"
Break Room - South
1 NEW WALL MOUNTED ACCESS LADDER. SEE DETAIL 5/1384-A/521.
KEYNOTES
Revisions: Date:
65% Design Development Submittal 07/15/2021
P-6
WP-9
WP-4
WP-8
VB-1
WP-9
WP-4
WP-8
VB-1
WP-9
WP-4
WP-8
VB-1
WP-9
WP-4
WP-8
VB-1
P-6 P-6 P-6
P-6
WP-9
WP-4
2'
- 6
4"
TO
P
O F
W
AL
L
PR
O
TE
CT
IO
N
TY
P.
LEVEL 2
18' - 8"
P-6
WP-5
WP-4
WP-9
WP-8
VB-1
WP-4
WP-9
WP-8
VB-1
WP-4
WP-9
WP-8
VB-1
P-6 P-6 P-6 P-6 P-6
WP-4
WP-9
VB-1
WP-4
WP-9
VB-1
WP-5
WP-5
WP-9
VB-1
WP-9
VB-1
WP-4P-6
P-5
4" 2'
- 6
TO
P
O F
W
AL
L
PR
O
TE
CT
IO
N
TY
P.
LEVEL 2
18' - 8"
P-6 P-6 P-6 P-6 P-6 P-6
WP-4
WP-9
WP-8
VB-1
WP-4
WP-9
WP-8
VB-1
WP-4
WP-9
WP-8
VB-1
WP-4
WP-9
WP-8
VB-1
WP-4
WP-9
WP-8
VB-1
P-5
WP-5 WP-5
TO
P
O F
W
AL
L
PR
O
TE
CT
IO
N
TY
P.
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. VA CONTRACT NO.
AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ 70-129AREAG70-131AREAH AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ70-129AREAG70-131AREAH
C U s e rs \l h o ff m a n
\D o c u m e n ts
\6
A rc h (C e n tr a l2 lh o ff m a n N
X Y
V .r v t
/1
/2
:2
:1
P
M
09/07/2021
ARCHITECTURAL - INTERIOR ELEVATIONS EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A420
ISSUE FOR BID
18-11636C26319D0022
1/4" = 1'-0"
ELEVATION - CORRIDOR C2-102
1/4" = 1'-0"
ELEVATION - CORRIDOR C2-110/C2-112
1/4" = 1'-0"
ELEVATION - CORRIDOR C2-114/C2-113
1. REFER TO SHEETS 1384-A001 & 1384-A002 FOR GENERAL NOTES AND MOUNTING HEIGHT
INFORMATION.
2. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION, PLUMBING, ELECTRICAL, MECHANICAL AND STRUCTURAL DRWAINGS FOR FULL SCOPE OF WORK.
3. REFER TO SHEETS 1384-A102 & 1384-A501 FOR PARITITION TYPES AND LOCATIONS.
GENERAL SHEET NOTESKEYNOTES
Revisions: Date:
LEVEL 3 INTERSTITIAL
47' - 7 1/2"
LEVEL 4 INTERSTITIAL
66' - 3 1/2"
LEVEL 3
37' - 4"
LEVEL 4
56' - 0"
ROOF DECK
74' - 8"
BTM OF DECKING
34' - 11 1/2"
1 1
1 1
1 1
1 1
1 1
1 1
P-6
P-6
P-6
P-6 P-6 P-6
P-6 P-6
P-6
1384-A513
1384-A312
3'
- 7
9"
4'
- 0
2' - 10 1/2"
P-6
P-6
P-6P-6
1384-A304
8 8
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. VA CONTRACT NO.
AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ 70-129AREAG70-131AREAH AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ70-129AREAG70-131AREAH
C U s e rs \l h o ff m a n
\D o c u m e n ts
\6
A rc h (C e n tr a l2 lh o ff m a n N
X Y
V .r v t
/1
/2
:2
:2
P
M
09/07/2021
ARCHITECTURAL - INTERIOR ELEVATIONS EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A421
ISSUE FOR BID
18-11636C26319D0022
1/4" = 1'-0"
GREEN ROOF ELEVATION - NORTH
1. REFER TO SHEETS 1384-A001 & 1384-A002 FOR GENERAL NOTES AND MOUNTING HEIGHT
INFORMATION.
2. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION, PLUMBING, ELECTRICAL, MECHANICAL AND STRUCTURAL DRWAINGS FOR FULL SCOPE OF WORK.
3. REFER TO SHEETS 1384-A102 & 1384-A501 FOR PARITITION TYPES AND LOCATIONS.
GENERAL SHEET NOTES
KEYNOTES
1 EXISTING ACOUSTIC WALL PANELS TO REMAIN. PROTECT DURING
CONSTRUCTION. CONTRACTOR RESPONSIBLE TO REPLACE ANY EXISTING
ACOUSTICAL WALL PANELS DAMAGED DURING CONSTRUCTION. IF
REPLACEMENT PANELS TO MATCH EXISTING CANNOT BE FOUND,
CONTRACTOR TO REPLACE ALL ACOUSTICAL WALL PANELS WITHIN
ATRIUM.
2 MATCH EXISTING REVEAL AT NEW DUCTWORK ENCLOSURE. REFER TO
DTL 3/1384-A501.
3 NEW WALL MOUNTED DIFFUSER. REFER TO MECHANICAL DRAWINGS.
4 NEW SOFFIT AT ROOF SLAB. REFER TO SECTIONS 2/1384-A312 AND
3/1384-A312 FOR ADDITIONAL INFORMATION.
5 NEW LOUVER. REFER TO DETAIL 7/1384-A513.
6 PATCH AND REPAIR EXISTING WALL TO ACCOMODATE SPRINKLER AND
MECHANICAL SCOPE OF WORK PER MECHANICAL AND FIRE PROTECTION
DRAWINGS. PAINT TO MATCH EXISTING.
7 EXISTING SIDEWALL GRILLE TO BE RELOCATED TO THIS LOCATION. REFER
TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
8 PROVIDE 2'X2' ACCESS PANEL, ON SIDE WALL OF DUCT ENCLOSURE, AT
7'-0" A.F.F. BASIS OF DESIGN: WIND LOCK STEALTH HINGES ACCESS DOOR
TRHAP-24X24.
Revisions: Date:
LEVEL 4 INTERSTITIAL
66' - 3 1/2"
LEVEL 3
37' - 4"
LEVEL 4
56' - 0"
ROOF DECK
74' - 8"
BTM OF DECKING
34' - 11 1/2"
1 1
1 1
P-6
P-6
P-6
P-6
P-6
P-6
P-6
P-6
P-6
P-6
P-6
P-6
P-6
P-6
P-6
P-6
1384-A304
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. VA CONTRACT NO.
AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ 70-129AREAG70-131AREAH AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ70-129AREAG70-131AREAH
C U s e rs \l h o ff m a n
\D o c u m e n ts
\6
A rc h (C e n tr a l2 lh o ff m a n N
X Y
V .r v t
/1
/2
:2
:3
P
M
09/07/2021
ARCHITECTURAL - INTERIOR ELEVATIONS EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A422
ISSUE FOR BID
18-11636C26319D0022
1/4" = 1'-0"
GREEN ROOF ELEVATION - EAST
1. REFER TO SHEETS 1384-A001 & 1384-A002 FOR GENERAL NOTES AND MOUNTING HEIGHT
INFORMATION.
2. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION, PLUMBING, ELECTRICAL, MECHANICAL AND STRUCTURAL DRWAINGS FOR FULL SCOPE OF WORK.
3. REFER TO SHEETS 1384-A102 & 1384-A501 FOR PARITITION TYPES AND LOCATIONS.
GENERAL SHEET NOTES
KEYNOTES
1 EXISTING ACOUSTIC WALL PANELS TO REMAIN. PROTECT DURING
CONSTRUCTION. CONTRACTOR RESPONSIBLE TO REPLACE ANY
EXISTING ACOUSTICAL WALL PANELS DAMAGED DURING
CONSTRUCTION. IF REPLACEMENT PANELS TO MATCH EXISTING
CANNOT BE FOUND, CONTRACTOR TO REPLACE ALL ACOUSTICAL
WALL PANELS WITHIN ATRIUM.
Revisions: Date:
LEVEL 4 INTERSTITIAL
66' - 3 1/2"
LEVEL 3
37' - 4"
LEVEL 4
56' - 0"
ROOF DECK
74' - 8"
BTM OF DECKING
34' - 11 1/2"
P-6 P-6P-6
P-6
P-6
1 1
1 1
1 1
1 1
P-6
P-6
P-6
P-6
P-6
P-6
1384-A304
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. VA CONTRACT NO.
AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ 70-129AREAG70-131AREAH AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ70-129AREAG70-131AREAH
C U s e rs \l h o ff m a n
\D o c u m e n ts
\6
A rc h (C e n tr a l2 lh o ff m a n N
X Y
V .r v t
/1
/2
:2
:4
P
M
09/07/2021
ARCHITECTURAL - INTERIOR ELEVATIONS EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A423
ISSUE FOR BID
18-11636C26319D0022
1/4" = 1'-0"
GREEN ROOF ELEVATION - SOUTH
1. REFER TO SHEETS 1384-A001 & 1384-A002 FOR GENERAL NOTES AND MOUNTING HEIGHT
INFORMATION.
2. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION, PLUMBING, ELECTRICAL, MECHANICAL AND STRUCTURAL DRWAINGS FOR FULL SCOPE OF WORK.
3. REFER TO SHEETS 1384-A102 & 1384-A501 FOR PARITITION TYPES AND LOCATIONS.
GENERAL SHEET NOTES
KEYNOTES
1 EXISTING ACOUSTIC WALL PANELS TO REMAIN. PROTECT DURING
CONSTRUCTION. CONTRACTOR RESPONSIBLE TO REPLACE ANY
EXISTING ACOUSTICAL WALL PANELS DAMAGED DURING
CONSTRUCTION. IF REPLACEMENT PANELS TO MATCH EXISTING
CANNOT BE FOUND, CONTRACTOR TO REPLACE ALL ACOUSTICAL
WALL PANELS WITHIN ATRIUM.
Revisions: Date:
LEVEL 4 INTERSTITIAL
66' - 3 1/2"
LEVEL 3
37' - 4"
LEVEL 4
56' - 0"
ROOF DECK
74' - 8"
BTM OF DECKING
34' - 11 1/2"
1 1
1 1
1 1
1 1
1 1
1 1
P-6
P-6
P-6
P-6
P-6
P-6
P-6
P-6 P-6
P-6
P-6
1384-A304
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. VA CONTRACT NO.
AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ 70-129AREAG70-131AREAH AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ70-129AREAG70-131AREAH
C U s e rs \l h o ff m a n
\D o c u m e n ts
\6
A rc h (C e n tr a l2 lh o ff m a n N
X Y
V .r v t
/1
/2
:2
:5
P
M
09/07/2021
ARCHITECTURAL - INTERIOR ELEVATIONS EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A424
ISSUE FOR BID
18-11636C26319D0022
1/4" = 1'-0"
GREEN ROOF ELEVATION - West
1. REFER TO SHEETS 1384-A001 & 1384-A002 FOR GENERAL NOTES AND MOUNTING HEIGHT
INFORMATION.
2. REVIEW THIS DRAWING IN CONJUNCTION WITH CORRESPONDING FIRE PROTECTION, PLUMBING, ELECTRICAL, MECHANICAL AND STRUCTURAL DRWAINGS FOR FULL SCOPE OF WORK.
3. REFER TO SHEETS 1384-A102 & 1384-A501 FOR PARITITION TYPES AND LOCATIONS.
GENERAL SHEET NOTES
KEYNOTES
1 EXISTING ACOUSTIC WALL PANELS TO REMAIN. PROTECT DURING
CONSTRUCTION. CONTRACTOR RESPONSIBLE TO REPLACE ANY
EXISTING ACOUSTICAL WALL PANELS DAMAGED DURING
CONSTRUCTION. IF REPLACEMENT PANELS TO MATCH EXISTING
CANNOT BE FOUND, CONTRACTOR TO REPLACE ALL ACOUSTICAL
WALL PANELS WITHIN ATRIUM.
Revisions: Date:
NOT
RATED
NOT
LISTED
NOT
RATED
NOT
LISTED
NOT
RATED
NOT
RATED
1HR
NOT
RATED
NOT
RATED
NOT
RATED
NOT
RATED
NOT
RATED
NOT
RATED
NOT
LISTED
NOT
LISTED
NOT
LISTED
1"
S E
C
TI
O N
V
IE
W
S E
C
TI
O N
V
IE
W
S E
C
TI
O N
V
IE
W S
E C
TI
O
N V
IE
W
ACOUSTICAL SEALANT, CONTINUOUS BOTH SIDES TOP AND BOTTOM
METAL RUNNER, CONTINUOUS
(1) LAYER 5/8" (TYPE-X) GYPSUM BOARD ON EACH SIDE, EXTEND
TO
UNDERSIDE OF STRUCTURE ABOVE (USE BOARD IF TO RECEIVE
CERAMIC TILE)
METAL STUD (18-20 GA.) FRAMING @ 16" O.C. MAX. EXTEND TO
STRUCTURE ABOVE.
METAL RUNNER, CONTINUOUS. SECURE TO CONCRETE SLAB @ 24" O.C.
WALL BASE - SEE FINISHED SCHEDULE.
METAL RUNNER, CONTINUOUS.
(1) LAYER 5/8" (TYPE-X) GYPSUM BOARD, U.N.O.
BELOW.
EXTEND TO UNDERSIDE OF STRUCTURE.
METAL STUD (18-20 GA.) FRAMING @ 16" O.C. MAX. EXTEND TO
UNDERSIDE OF STRUCTURE ABOVE.
SOUND ATTENUATION BATT. INSULATION.
SEE SCHEDULE BELOW FOR PARTITION WIDTH.
ACOUSTICAL SEALANT, CONTINUOUS BOTH
SIDES
TOP AND BOTTOM.
HEAD TRACK SYSTEM TO ACCOMODATE
DEFLECTION
CRITERIA SHOWN ON STRUCTURAL DRAWINGS.
(1) LAYER 5/8" GYPSUM BOARD EACH SIDE,
U.N.O.
BELOW. EXTEND TO UNDERSIDE OF EXISTING
STRUCTURE.
(2) ROWS OF METAL STUD (18-20 GA.) FRAMING
@ 16" O.C. MAX., EXTEND TO STRUCTURE
ABOVE.
SOUND ATTENUATION BATT. INSULATION.
LINE OF CEILING
LINE OF CEILING
EXISTING WALL SYSTEM
S E
C
TI
O N
V
IE
W P
LA
N
V
IE
W
ACOUSTICAL SEALANT, CONTINUOUS BOTH SIDES TOP AND BOTTOM.
CONTINUOUS METAL RUNNER.
METAL STUD (18-20 GA.) FRAMING @ 16" O.C. MAX.,
EXTEND TO STRUCTURE ABOVE.
HEAD TRACK SYSTEM TO ACCOMMODATE DEFLECTION
CRITERIA
SHOWN ON STRUCTURAL DRAWINGS.
LINE OF CEILING
S E
C
TI
O N
V
IE
W P
LA
N
V
IE
W
P
LA
N V
IE
W
METAL STUD BRACING @ 48" O.C. MAX. VERTICALLY.
SOUND ATTENUATION BATT. INSULATION.
HEAD TRACK SYSTEM TO ACCOMMODATE DEFLECTION
CRITERIA
SHOWN ON STRUCTURAL DRAWINGS.
METAL RUNNER, CONTINUOUS.
HEAD TRACK SYSTEM TO ACCOMMODATE DEFLECTION
CRITERIA
SHOWN ON STRUCTURAL DRAWINGS
SOUND ATTENUATION BATT. INSULATION
METAL RUNNER, CONTINUOUS.
(1) LAYER 5/8" (TYPE-X) GYPSUM BOARD, U.N.O. BELOW.
EXTEND TO UNDERSIDE OF STRUCTURE.
METAL STUD (18-20VGA.) FRAMING @ 16" O.C. MAX.,
EXTEND TO STRUCTURE ABOVE.
SOUND ATTENUATION BATT. INSULATION.
LINE OF CEILING
P
LA
N V
IE
W
S E
C
TI
O N
V
IE
W
HEAD TRACK SYSTEM TO ACCOMMODATE DEFLECTION
CRITERIA
SHOWN ON STRUCTURAL DRAWINGS.
METAL RUNNER, CONTINUOUS SECURE TO CONCRETE SLAB @ 24" O.C.
S E
C
TI
O N
V
IE
W P
LA
N
V
IE
W S
E C
TI
O
N V
IE
W
S E
C
TI
O N
V
IE
W P
LA
N
V
IE
W S
E C
TI
O
N V
IE
W
METAL STUD (18-20 GA.) FRAMING @ 16" O.C. MAX.
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH.
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH.
ACOUSTICAL SEALANT, CONTINUOUS TOP AND BOTTOM.
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH.
ACOUSTICAL SEALANT, CONTINUOUS BOTH TOP AND BOTTOM.
SOUND ATTENUATION BATT. INSULATION.
METAL RUNNER, SECURE TO CONCRETE SLAB @ 24" O.C.
WALL BASE - SEE FINISHED SCHEDULE.
METAL RUNNER, CONTINUOUS. SECURE TO CONCRETE SLAB @ 24" O.C.
WALL BASE - SEE FINISHED SCHEDULE.
ACOUSTICAL SEALANT, CONTINUOUS BOTH TOP AND BOTTOM.
WALL BASE - SEE FINISHED SCHEDULE.
METAL RUNNER, CONTINUOUS. SECURE TO
CONCRETE
SLAB @ 24" O.C.
WALL BASE - SEE FINISHED SCHEDULE.
ACOUSTICAL SEALANT, CONTINUOUS BOTH
SIDES
TOP AND BOTTOM.
METAL RUNNER, CONTINUOUS. SECURE TO CONCRETE SLAB @ 24" O.C. TAPE POLYETHYLENE SHEET TO FLOOR W/ PAINTERS TAPE, SEE ICRA PLAN & SCHEDULE FOR DETAILS.
FIRE RESISTIVE SEALANT, CONTINUOUS BOTH SIDES TOP AND BOTTOM.
TAPE POLYETHYLENE SHEET TO UNDERSIDE OF STRUCTURE
W/ DUCT TAPE - SEE ICRA PLAN & SCHEDULE FOR DETAILS
6 MM (MIN.) FIRE RETARDANT POLYETHYLENE SHEET.
(1) LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD EACH SIDE EXTENDING
TO UNDERSIDE OF STRUCTURE.
FIRE RESISTIVE SEALANT, CONTINUOUS BOTH SIDES TOP AND BOTTOM.
LINE OF
STRUCTURAL
SLAB
LINE OF
STRUCTURAL
SLAB
LINE OF CEILING
LINE OF
STRUCTURAL
SLAB
LINE OF
STRUCTURAL
SLAB
UNDERSIDE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
6" HOLD,
MIN.
S E
C
TI
O N
V
IE
W
LINE OF
STRUCTURAL
SLAB
LINE OF CEILING
LINE OF
STRUCTURAL
SLAB
UNDERSIDE OF
STRUCTURE
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
ACOUSTICAL SEALANT, CONTINUOUS TOP AND BOTTOM.
FIRE RESISTIVE SEALANT, CONTINUOUS BOTH SIDES TOP AND BOTTOM.
FIRE RESISTIVE SEALANT, CONTINUOUS BOTH SIDES TOP AND BOTTOM.
(1) LAYER 5/8" (TYPE-X) GYPSUM BOARD ON EACH SIDE, NUMBER OF 5/8"
LAYERS AS SCHEDULED. EXTEND TO UNDERSIDE OF STRUCTURE
ABOVE.
NON RATED PARTITION
WALL ASSEMBLY.
LINE OF CEILING
UNDERSIDE OF STRUCTURE
TOP FLUTE OF STEEL DECK
VARIES
16 GA. LONG LEG CHANNEL FASTENED TO CLOSURE PLATE.
DO NOT SCREW GYPSUM WALL BOARD TO LONG LEG
CHANNEL.
20 GA. METAL CLOSURE PLATE
SECURED
TO UNDERSIDE OF STRUCTURE.
METAL RUNNER, CONTINUOUS.
FASTENING SCREWS.
COMPRESSIBLE FILLER.
1"
RATED PARTITION WALL
ASSEMBLY.
LINE OF CEILING
UNDERSIDE OF STRUCTURE
VARIES
16 GA. LONG LEG CHANNEL FASTENED TO CLOSURE PLATE.
DO NOT SCREW GYPSUM WALL BOARD TO LONG LEG
CHANNEL.
METAL RUNNER, CONTINUOUS.
FASTENING SCREWS.
COMPRESSIBLE FILLER.
SOUND ATTENUATION BATT.
AT DECK FLUTES.
20 GA. METAL CLOSURE PLATE
SECURED
TO UNDERSIDE OF STRUCTURE.
COMPRESSIBLE FILLER PER FIRE
RATED ASSEMBLY AS REQUIRED,
BOTH SIDES.
TOP FLUTE OF STEEL DECK.
SOUND ATTENUATION BATT.
AT DECK FLUTES.
A C
E
E1
C1
B
D
C2
D1
K
NON-RATED PARTITIONS
WALL TAG GYPSUM BOARD
STUD
WIDTH
PARTITION
WIDTH
FIRE
RATING
UL
LISTING REMARKS
(1) LAYER 5/8" (TYPE-X),
EACH SIDE
4-7/8"3-5/8"
NON-RATED INSULATED FURRING PARTITION AT EXISTING WALL
WALL TAG GYPSUM BOARD
STUD
WIDTH
PARTITION
WIDTH
FIRE
RATING
UL
LISTING REMARKS
(1) LAYER 5/8" (TYPE-X)
ON EXPOSED SIDE 3-5/8"
CHASE PARTITION
WALL TAG GYPSUM BOARD
STUD
WIDTH
PARTITION
WIDTH
FIRE
RATING
UL
LISTING REMARKS
3-5/8"
3-5/8"
SEE
PLAN
(1) LAYER 5/8"
(1) LAYER 5/8" CBB
ON EXPOSED SIDE 4-1/4"
CBB (CEMENTITIOUS BACKER BD.)
ON TOILET ROOM OR HAC SIDE
RATED PARTITIONS
WALL TAG GYPSUM BOARD
STUD
WIDTH
PARTITION
WIDTH
FIRE
RATING
UL
LISTING REMARKS
(1) LAYER 5/8" (TYPE-X),
EACH SIDE 4-7/8"3-5/8"
NON-RATED PARTITION - FINISH ONE SIDE
WALL TAG GYPSUM BOARD
STUD
WIDTH
PARTITION
WIDTH
FIRE
RATING
UL
LISTING REMARKS
(1) LAYER 5/8" (TYPE-X),
ON EXPOSED SIDE 4-1/4"3-5/8"
(1) LAYER 5/8" (TYPE-X),
ON EXPOSED SIDE 3-1/8"2-1/2"
(1) LAYER 5/8" (TYPE-X)
ON EXPOSED SIDE
(1) LAYER 5/8"
CBB (CEMENTITIOUS BACKER BD.)
ON BOTH SIDES,
TEMPORARY RATED ICRA PARTITION ASSEMBLY
WALL TAG GYPSUM BOARD
STUD
WIDTH
PARTITION
WIDTH
FIRE
RATING
UL
LISTING REMARKS
(1) LAYER 5/8" (TYPE-X)
EACH SIDE 4-7/8"3-5/8" 1HR U419
E
A B C
D K
STC-34 MIN. RATING, CBB (CEMENTITIOUS BACKER BD.)
ON TOILET RM. OR HAC SIDE 1HR U419
4-1/4"
4-5/8"4"
3-5/8"
SPACE BETWEEN
EXISTING & FURRING WALLS
CBB (CEMENTITIOUS BACKER BD.)
ON TOILET RM. SIDE,
STC-44 MIN. RATING
SEE
PLAN
STC- 44 MIN. RATING
DETAIL - NON-RATED SLIP JOINT CONNECTION AT METAL DECK1
DETAIL - RATED SLIP JOINT CONNECTION AT METAL DECK2
25 GA METAL STUD @ 24" O.C. WITH
3-1/2"-4" BATT. INSULATION
STC- 50 MIN. RATING
B3
(2) LAYER 5/8" (TYPE-X),
EACH SIDE 10-1/2"8" 1HR V435
STC- 52 MIN. RATING
CBB (CEMENTITIOUS BACKER BD.)
ON TOILET RM. SIDE
NOT
RATED
NOT
LISTED
E2 3-5/8"(1) LAYER 5/8" 8-1/2"
B2
(1) LAYER 5/8" (TYPE-X),
EACH SIDE 4-7/8"3-5/8" 1HR U419
STC- 44 MIN. RATING
CBB (CEMENTITIOUS BACKER BD.)
ON TOILET RM. SIDE
NOT
RATED
NOT
LISTED
A1
(1) LAYER 5/8" (TYPE-X),
EACH SIDE
7-1/4"6"
STC-34 MIN. RATING, CBB (CEMENTITIOUS BACKER BD.)
ON TOILET RM. OR HAC SIDE
NOT
RATED
NOT
LISTED
D2
(1) LAYER 5/8" (TYPE-X),
ON EXPOSED SIDE 6-5/8"6"
3/ 8"
3/ 4"
JOINT COMPOUND
ALUM. "J" MOLDING
SCREW TO STUDS
OR RUNNER 16" O.C.
5/8" GYP. WALLBOARD
DOUBLE FRAMING @
VERTICAL JOINT ONLY -
DO NOT INTERRUPT
HORIZONTAL FRAMING
ALUMINUM BACKER
PLATE - FASTEN TO ONE
SIDE OF JOINT ONLY,
0.050" THICK
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. VA CONTRACT NO.
AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ 70-129AREAG70-131AREAH AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ70-129AREAG70-131AREAH
C U s e rs \l h o ff m a n
\D o c u m e n ts
\6
A rc h (C e n tr a l2 lh o ff m a n N
X Y
V .r v t
/1
/2
:2
:5
P
M
09/07/2021
ARCHITECTURAL - PARTITION TYPES EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A501
ISSUE FOR BID
18-11636C26319D0022
3" = 1'-0"
WALL DETAIL - TYP. GYP. BD. REVEAL
Revisions: Date:
65% Design Development Submittal 07/15/2021
BB
22 GA METAL LINER. OVERLAP SEAMS IN
DIRECTION OF AIR FLOW (UPWARD)
INSTALL ALUMINUM LINEAR GRILLE AT TOP
OF WALL. SEE DETAIL 5/1384-A513
8" METAL STUD FRAMING,
@ 16" O.C. W/ SOUND
ATTENUATION BATT
INSULATION.
(2) LAYERS 5/8" GYP. BD -
PAINTED, BOTH SIDES OF
STUD WALL
(2) LAYERS 5/8" GYP. BD -
PAINTED,
(2) LAYERS 5/8" GYP. BD -
PAINTED, BOTH SIDES OF
STUD WALL
EXISTING COLUMN
ENCLOSURE TO REMAIN.
EXISTING CONSTRUCTION:
• 3/4" PLASTER ON
METAL LATHE
• 6" 20 GA. STUDS
@ 12" O.C. -
• NO RUNNERS
• 22 GA. SHEET METAL
LINER SCREWED TO
STUDS
PROVIDE BACKER ROD AND
SEALANT WHERE NEW WALL
MEETS EXISTING COLUMN.
PROVIDE BACKER ROD AND
SEALANT WHERE NEW WALL
MEETS EXISTING COLUMN.
1384-A513
Sim
BB
1384-A512
NEW HSS 6X6X3/8 COLUMN
REFER TO STRUCTURAL
DRAWINGS
2-1/2" METAL STUD FRAMING
W/ 5/8" GYP. BD. - PAINTED.
TYP.
Y
1384-A512
NEW HSS 6X6X3/8 COLUMN.
REFER TO STRUCTURAL
DRAWINGS.
3-5/8" METAL STUD FRAMING
5/8" GYP. BD. - PAINTED, TYP.
NEW CORNER GUARDS
3-5/8" METAL STUD FRAMING, 16" O.C.
W/ 5/8" GYP. BD. ON BOTH SIDES - PAINTED.
SOUND ATTENUATION BATT INSULATION
TYP.
Y
1384-A601
NEW HSS 6X6X3/8 COLUMN
REFER TO STRUCTURAL DRAWINGS.
6" METAL STUD FRAMING, 16" O.C.
W/ 5/8" GYP. BD. ON BOTHER SIDES
PAINTED.
SOUND ATTENUATION
BATT INSULATION
NEW DOOR FRAME
BB
1384-A513
LINE OF NEW DUCT
WORK - REFER TO
MECHANICAL DRAWINGS.
5/8" GYP. BD. ON 3-5/8"
METAL STUD FRAMING,
16" O.C.
FRAME AROUND NEW
DUCT WORK.
5/8" GYP. BD. ON 6"
METAL STUD FRAMING.
FRAME AROUND NEW
DUCT WORK
EXISTING WINDOWS TO
REMAIN - PROTECT DURING
CONSTRUCTION.
EXISTING WINDOWS TO
REMAIN - PROTECT DURING
CONSTRUCTION.
1384-A304
AA
PROVIDE WINDOW FILM AT THIS WINDOW
LOCATION ON THE THIRD AND FOURTH FLOOR.
BASIS OF DESIGN:
3M CRYSTAL GLASS FINISHES
7725SE-324
FROSTED CRYSTAL
LINE OF NEW DUCT
WORK - REFER TO
MECHANICAL DRAWINGS.
5/8" GYP. BD. ON 3-5/8"
METAL STUD FRAMING,
16" O.C.
FRAME AROUND NEW
DUCT WORK.
5/8" GYP. BD. ON 6"
METAL STUD FRAMING.
FRAME AROUND NEW
DUCT WORK
5/8" GYP. BD. ON 3-5/8" METAL
STUD FRAMING, 16" O.C.
FRAME AROUND NEW DUCT
WORK.
EXISTING WINDOWS TO
REMAIN - PROTECT DURING
CONSTRUCTION.
EXISTING WINDOWS TO
REMAIN - PROTECT DURING
CONSTRUCTION.
1384-A312
1384-A304
Z
LINE OF NEW DUCT
WORK - REFER TO
MECHANICAL DRAWINGS.
5/8" GYP. BD. ON 6"
METAL STUD FRAMING.
FRAME AROUND NEW
DUCT WORK
5/8" GYP. BD. ON 3-5/8" METAL
STUD FRAMING, 16" O.C.
FRAME AROUND NEW DUCT
WORK.
EXISTING WINDOWS TO
REMAIN - PROTECT DURING
CONSTRUCTION.
22 GA SHEET METAL
LINER
OVERLAP SEAMS IN
DIRECTION OF AIRFLOW
(DOWNWARD).
CREATE AIR TIGHT SEAL
AROUND DUCT PENTRATION.
1384-A513
NEW LOUVER
1384-A304
BB
22 GA METAL LINER. OVERLAP SEAMS IN
DIRECTION OF AIR FLOW (UPWARD)
INSTALL ALUMINUM LINEAR GRILLE AT TOP
OF WALL. SEE DETAIL 5/1384-A513
8" METAL STUD FRAMING,
@ 16" O.C. W/ SOUND
ATTENUATION BATT
INSULATION.
(2) LAYERS 5/8" GYP. BD -
PAINTED, BOTH SIDES OF
STUD WALL
(2) LAYERS 5/8" GYP. BD -
PAINTED,
(2) LAYERS 5/8" GYP. BD -
PAINTED, BOTH SIDES OF
STUD WALL
EXISTING COLUMN ENCLOSURE TO REMAIN.
EXISTING CONSTRUCTION:
• 3/4" PLASTER ON METAL LATHE
• 6" 20 GA. STUDS @ 12" O.C.-
• NO RUNNERS
• 22 GA. SHEET METAL LINER SCREWED
TO STUDS
PROVIDE BACKER ROD AND
SEALANT WHERE NEW WALL
MEETS EXISTING COLUMN.
PROVIDE BACKER ROD AND
SEALANT WHERE NEW WALL
MEETS EXISTING COLUMN.
MODIFY EXISTING GRILLE
ASSEMBLY TO RECIEVE NEW
WALL CONSTRUCTION
PROVIDE 60MIL RUBBER MEMBRANE
ON INTERIOR OF PLANTER. REFER
TO DETAILS SHEET 1384-A513
1384-A513
Sim
1384-A513
Sim
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
Bancroft Project No. VA CONTRACT NO.
09/07/2021
ARCHITECTURAL - PLAN DETAILS EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A502
ISSUE FOR BID
18-11636C26319D0022
1" = 1'-0"
PLAN DETAIL - NEW CHASE @ EXISTING COLUMN
1 1/2" = 1'-0"
PLAN DETAIL - COLUMN ENCLOSURE
1 1/2" = 1'-0"
PLAN DETAIL - CHASE WALL @ COLUMN
1 1/2" = 1'-0"
PLAN DETAIL - COLUMN ENCLOSURE
1" = 1'-0"
PLAN DETAIL - NEW DUCT ENCLOSURE
1" = 1'-0"
PLAN DETAIL - NEW DUCT ENCLOSURE
1" = 1'-0"
PLAN DETAIL - NEW DUCT ENCLOSURE
1" = 1'-0"
PLAN DETAIL - EXISTING GRILLE AT NEW PLANTER WALL
Revisions: Date:
65% Design Development Submittal 07/15/2021
A
LI
G N
1 1/2" COUNTERTOP- W/ ROUNDED CORNERS W/
SUMMIT 'T' DETAIL EDGES ON PLYWOOD SUB
STRUCTURE
STAINLESS STEEL UNDERMOUNT
SINK & FAUCET- SEE MEP
DRAWINGS
PROVIDE CONT. SILICONE
SEALANT ALL SIDES (TYP.)
NOTE:
MILLWORK DIMENSIONS TO BE
VERIFIED WITH SINK SPECIFICATIONS AND
CLEARANCES
1 X FRT WD. BLOCK'G- TYP.
3/4" REMOVABLE PLYWD. &
P.LAM,. VALANCE W/ Z-CLIPS
MOUNTED TO PRE-FABRICATED BRACKET EACH END
METAL BACKING PLATES
1/2" APRON TO MATCH CABINET FINISH
1/8" SOLID SURFACE BACK
SPLASH 4" HEIGHT & END
SPLASHES WHERE COUNTER
MEETS WALL
2'
- 6
1' - 0" 5 1/2" 6" 1 1/2"
P-LAM FINISHED END PANEL
1/
2" 6"
2' - 1"
3'
- 0
STAINLESS STEEL PRE-FABRICATED SIDE
PANEL BRACKET
6"
SOLID SURFACE BACKSPLASH
AND SIDESPLASH WHERE
INDICATED
REFER TO ELEVATION.
COUNTERTOP WITH ROUNDED CORNERS (TYP.)
TYP UNO
2' - 1"
DRAWER
WIRE PULL, TYPICAL
3/4" PLAM ADJUSTABLE SHELF
PLAM BASE CABINET
SCHEDULED BASE
DOOR, LOCKABLE
SEALANT.METAL BACKING
PLATE. SEE DETAIL
S E
E I N
T E
R
IO
R E
L E
V A
T
IO
N
4"
3"
1/
2"
4"
1/
2"
SE
E
IN
TE
RI
O
R
EL
EV
AT
IO
N
4"
2" DIA. GROMMET W/ PLASTIC CAP. PROVIDE
ON ALL WORK SURFACES. COORDINATE
LOCATION WITH EQUIPMENT INSTALLATION.
BASE AS SCHEDULED
REINSTALL SALVAGED WIREMOLD,
PATCH AND PAINT AS REQUIRED
SS-1 COUNTERTOP WITH ROUNDED CORNERS (TYP.)
SEE PLAN
EXISTING COUNTER SUPPORT TO
REMAIN
METAL BACKING
PLATE. SEE DETAIL
EXISTING PLYWOOD EQUIPMENT
MANAGEMENT BOX TO REMAIN 4" WIRE PULL, ONE PER DOOR
MELAMINE INTERIOR
3/4" ADJUSTABLE WHITE
MELAMINE SHELVES
METAL BRACKET
PLASTES
P.LAM. SLOPED TOP
1' - 0"
U .N
.O
METAL SHELF SUPPORTS, 5MM
HOLES, 32MM ON CENTER
P-LAM (PL-2) ON 3/4" PLYWOOD ON
ALL EXPOSED SURFACES
CONCEALED SELF-CLOSING HINGES WITH
DOOR BUMPER PADS
CONTINUOUS WOOD CLEATS,
REINFORCE AS NECESSARY.
1384-A511
Sim
1384-A511
Sim
1384-A511
Sim
AA
1384-A419 17
1384-A511
Sim
1384-A511
Sim
1384-A511
Sim
1384-A511
Sim
1384-A511
Sim
BREAK
ROOM
2P-138
PROVIDE SOLID SURFACE END
PANEL WHERE COUNTER TOP
CHANGES HEIGHT.
1/ 2"
1/
2"
2'
- 0
3' - 8"
P-LAM (PL-1) ON 3/4" PLYWOOD
VENDING MACHINES
METAL STUD (18-20 GA.) FRAMING
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. VA CONTRACT NO.
AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ 70-129AREAG70-131AREAH AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ70-129AREAG70-131AREAH
C U s e rs \l h o ff m a n
\D o c u m e n ts
\6
A rc h (C e n tr a l2 lh o ff m a n N
X Y
V .r v t
/1
/2
:2
:1
P
M
09/07/2021
ARCHITECTURAL - CASEWORK DETAILS EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A511
ISSUE FOR BID
18-11636C26319D0022
1 1/2" = 1'-0"
BASE CABINET - SINK
1 1/2" = 1'-0"
BASE CABINET - TYPICAL
1 1/2" = 1'-0"
COUNTERTOP - TYPICAL
1 1/2" = 1'-0"
UPPER CABINET - TYPICAL
N
1/2" = 1'-0"
ENLARGED FLOOR PLAN - SURGICAL WAITING ROOM
N
1/2" = 1'-0"
ENLARGED FLOOR PLAN - BREAK ROOM 2P-138
1 1/2" = 1'-0"
UPPER CABINET - TYPICAL
Revisions: Date:
65% Design Development Submittal 07/15/2021
CRANK OPERATED
BOTTOM SEAL PROVIDES
2" OPERATING CLEARANCE
(+50"/-1.50")
STEEL, 4-WHEEL, BALL
BEARING TROLLEY
VINYL TOP SEAL
#17 TRACK, STEEL, PRE-
PAINTED OFF WHITE
DROPPED SOFFIT TRIM BY
MANUFACTURER
CONTRACTOR TO PROVIDE
SOUND ATTENUATING
BATT INSULATION - REFER
TO DETAIL 1/A312 FOR
ADDITIONAL INFORMATION
HANGER BRACKET BY
MANUFACTURER
HANGER RODS
5 1/2" BRACKET
4 1/2" GAGE
FINISHED
CEILING
FI
NI
SH
ED
C
EI
LI
NG
H
EI
G
HT
FINISHED
FLOOR
FA
BR
IC
AT
IO
N
HE
IG
HT
M
IN
7"
TRACK
4 1/4"
NOTE: REFER TO STRUCTURAL
DRAWINGS FOR STRUCTURAL SUPPORT
CAULKING BETWEEN JAMB
AND WALL
EXPANDABLE PANEL NOSE
WRAPPED WITH MATCHING
VINYL MATERIAL
JAMB WRAPPED WITH MATCHING
VINYL MATERIAL
CONTRACTOR TO PROVIDE
BLOCKING PER 7/A512
TRAVEL
0"-5.75"
CONTRACTOR TO
PROVIDE BLOCKING
PER 7/A512
JAMB WRAPPED
WITH MATCHING
VINYL MATERIAL
CAULKING
BETWEEN WALL
AND JAMB
MB MB MB MB
MB - MARKERBOARD
48" HIGH, COATED STEEL NON-POROUS WRITING SURFACE
FORMED AROUND PANEL EDGES. TOP AND BOTTOM EDGES
TRIMMED WITH MOLDING. COLOR SELECTION: WHITE 30" A.F.F.
IC2IC2
POCKET DOOR BY
OPERABLE WALL
MANUFACTURER - BASIS
OF DESIGN: MODERNFOLD
M
IN
. C
LR
2'
5"
M
IN
. C
LR
2'
5"
M
IN
. C
LR
4'
STACK DEPTH
2' - 8"
MINIMUM POCKET
3' - 2"
JAMB
1 1/4"
EXPANDABLE PANEL
3' - 6.69" (3' - 6.44")
PANEL NO. 2
3' - 6.44"
INTERMEDIATE PANELS
21' - 2.62"
JAMB
1 1/4"
INSTALLATION WIDTH
28' - 6 1/4"
MIN. CLR.
2' - 5"
MIN. CLR.
2' - 5"
HANDPULL
HINGED JAMB
3"
1' - 9"
1" REF.
9" 1' - 9"
HINGED JAMB
3"
OF TRACK
4' - 10"
RECESSED HANDPULL
FOOTBOLT (TYP.)
CONTRACTOR TO PROVIDE
SOUND ATTENUATING BATT
INSULATION
FA
BR
IC
AT
IO
N
HE
IG
HT
3/
4"
FI
NI
SH
ED
O
PE
NI
NG
H
EI
G
HT
FINISHED
CEILING
FINISHED
FLOOR
CAULKING BETWEEN
JAMB AND WALL
JAMB WRAPPED WITH
MATCHING VINYL MATERIAL
BLOCKING AND
REQUIREMENTS BY OTHERS
FOOT BOLT JAMB WRAPPED WITH
MATCHING VINYL MATERIAL
CAULKING BETWEEN WALL
AND JAMB
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. VA CONTRACT NO.
AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ 70-129AREAG70-131AREAH AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ70-129AREAG70-131AREAH
C U s e rs \l h o ff m a n
\D o c u m e n ts
\6
A rc h (C e n tr a l2 lh o ff m a n N
X Y
V .r v t
/1
/2
:2
:1
P
M
09/07/2021
ARCHITECTURAL - OPERABLE WALL DETAILS EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A503
ISSUE FOR BID
18-11636C26319D0022
1 1/2" = 1'-0"
OPERABLE WALL - HEADER/FOOTER
1 1/2" = 1'-0"
EXPANDABLE PANEL WITH JAMB
1 1/2" = 1'-0"
JAMB DETAIL
1/2" = 1'-0"
PANEL ELEVATION - TYP.
1/2" = 1'-0"
PANEL PLAN
1/2" = 1'-0"
POCKET LEFT - PLAN
1/2" = 1'-0"
POCKET LEFT - ELEVATION
1 1/2" = 1'-0"
POCKET LEFT - HEADER/FOOTER
1 1/2" = 1'-0"
POCKET LEFT - HINGED JAMB/CENTER PANEL
Revisions: Date:
CL DOOR WHERE OCCURS
REDUCER STRIP - REFER TO ROOM
FINISH SCHEDULE. JOHNSONITE
RRS-130-C , OR APPROVED EQUAL
EXPOSED CONCRETE FLOORSHEET VINYL
12"
CARPET
TS-3
TS-2
12" (MIN.)
3/8" PORCELAIN TILE
LVT
TRANSITION STRIP. REFER
TO ROOM FINISH LEGEND.
SOLID SURFACE OR
APPROVED EQUAL
LEVELING COMPOUND -
FEATHER DOWN TO
FLOOR ELEVATION
TS-1
LVT
TRANSITION STRIP. REFER
TO ROOM FINISH
LEGEND. JOHNSONITE
SLT-130-B, OR APPROVED
EQUAL
VINYL COVERED SURFACE
MOUNTED CORNER GUARD
SELF TAPPING SCREWS
BASIS OF DESIGN:
160 SURFACE MOUNT CORNER
GUARD BY INPRO
3"
3"
SURFACE
MOUNTED SNAP-
ON
VINYL CORNER
GUARD
SELF
DRILLING
SCREWS
R E
F E
R T
O P
A R
T
IT
IO
N
T Y
P E
S
2"
CAP STRIP
COVE FORM
FLOORING
METAL STUDS (20 GA.) AT
16" O.C.- TYP.
CONT. 8" HIGH (16 GA.)
STEEL BLOCKING PLATE,
ANCHOR TO STUDS / 2
SELF TAPING FLAT HEAD
SCREWS PER STUD
PROVIDE 8" HIGH X 48" LONG X 16 GAUGE CONTINUOUS
BACK-UP BLOCKING PLATES SECURELY ANCHORED WITH
FLAT HEAD SCREWS OVER METAL STUDS BEHIND ALL
TOILET
ACCESSORIES, BASE CABINETS, WALL CABINETS,
MILLWORK,
SHELVING, VISUAL DISPLAY BOARDS, WALL/ HANDRAIL (NEW
WALLS) AND ALL OTHER SURFACE MOUNTED ITEMS.
NOTE:
IF WOOD BLOCKING USED,
PROVIDE 1/2" MINIMUM
FIRE-RATED PLYWOOD.
1/8" REVEAL
ELEVATION
PLAN
FULLY RECESSED FIRE
EXTINGUISHER CABINET
5/8" GYP BD
SHIM AS REQ'D EA. SIDE
" A
FF
3-5/8" X 20 GA. METAL STUDS
AROUND FEC OPENING
1/8" 1/8"
METAL 1/8" REVEAL "Z" MOLD
AROUND OPENING, MTD TIGHT TO
FEC, FINISH FLUSH W/ 5/8" GWB
1-1/2" X 1/2" X 20 GA. METAL ANGLE @
ALL (4) SIDES OF RATED PARTITION
TYPE OPENING, ATTACH TO METAL
STUDS W/ #8 SELF-TAP SM SCREWS @
12" O.C.
NOTE:
FULLY RECESSED F.E.C. BY LARSON,
MODEL FS-2712-R W/ FULL CLEAR
ACRYLIC DOOR AND FLAT TRIM, OR
APPROVED EQUAL. UNIT TO CONTAIN
2-1/2 GAL. FIRE EXTINGUISHER
VERTICAL WALL
STUDS AT 16" ON
CENTER
CUT HORIZONTAL
FASTENER FROM
STUD. CONTRACTOR
TO COORDINATE
LOCATIONS.
FASTEN AT BOTH
ENDS WITH MIN.
4 TAPPING
SCREWS.
WALL FINISH
PLAN
ISOMET
RIC
T/RAIL
REFER TO
ELEVATIONS
FOR HEIGHT
NEW GYP. BD. WALL (U.N.O.) -
SEE RM. FINISH SCHEDULE FOR
WALL FINISH
CONTINUOUS 800 VINYL
COVER .080"
CONTINUOUS ALUMINUM 800
RETAINER .080"
800 MOUNTING BRACKET
16 GA. CONTINUOUS
METAL BACKING, 8"H
NOTE:
HANDRAIL AND BRACKET
PRODUCT INPRO #800 COLOR:
RIVEROCK, OR APPROVED
EQUAL
WALL PROTECTION - REFER TO
FINISH SCHEDULE
1/4 - 20 X 5" HEX HEAD SCREW
W/ PHILLIPS HEAD SLOT
1 1/2" 1 1/2"
3/
4"
3"
1/
2"
FINISH FACE
OF WALL
TOILET
ACCESSORIES
(AS SPECIFIED)
TYPICAL RESTROOM STALL PLAN
TOILET ACCESSORIES
(AS SPECIFIED)
TOILET PARTITION
AS SPECIFIED, TYP.
FIXTURE ELEVATION
NON - ACCESSIBLE W.C.
SIDE ELEVATION
HOOK (AS SPECIFIED)
DOOR ELEVATION SIDE ELEVATION
FINISH FACE
OF WALL
2' - 8" CLEAR DOOR
TOILET PARTITION
AS SPECIFIED, TYP.
ACCESSIBLE W.C.
HOOK AS
SPECIFIED
WALL
BUMPER
AS APPLIES -
(EXTERIOR
SIDE)
TOILET
ACCESSORIES
(AS SPECIFIED)
2' - 8" CLEAR DOOR
TOILET PARTITION
AS SPECIFIED, TYP.
ACCESSIBLE W.C.
HOOK
AS SPECIFIED
WALL BUMPER AS APPLIES -
(EXTERIOR SIDE)
TOILET
ACCESSORIES
(AS SPECIFIED)
FIXTURE ELEVATION SIDE ELEVATION DOOR ELEVATION SIDE ELEVATION
FIXTURE ELEVATION
SIDE ELEVATION DOOR ELEVATION SIDE ELEVATION
TYPICAL AMBULATORY STALL PLAN
TYPICAL ACCESSIBLE STALL PLAN
1384-A402.3
REFER TO PLAN
IN
SI
DE
D
IM
EN
SI
O
N
5'
- 0
REFER TO PLAN 1384-A402.3
5'
- 0
" C
LE
AR 3'
- 4
1'
- 0
8"
3'
- 6
1'
- 0
2'
- 9
3'
- 4
1'
- 6
3'
- 6
1'
- 0
6" 3' - 0"
1' - 6" 3' - 6"
REFER TO PLAN 1384-A402.3
1'
- 6
3'
- 4
2'
- 9
3'
- 4
RE
FE
R
TO
P
LA
N
-A
2.
UNO
EQ
UNO
EQ
EQ EQ
MAX
4"
CLOTHES HOOK AND
BUMPER AS
SPECIFIED
1'
- 1
6" 6"
1'
- 0
8"1'
- 1
NOTES:
A. THE MOUNTING HEIGHTS, CLEARANCES, AND CONFIGURATIONS SHOWN ON THIS SHEET ARE TYPICAL AND SHALL APPLY TO ALL INSTANCES OF THE ITEM (OR GROUP OF ITEMS) SHOWN UNLESS SPECIFICALLY NOTED OR DIMENSIONED OTHERWISE.
B. SPECIAL OR NON-TYPICAL MOUNTING HEIGHTS OCCUR ONLY WHERE INDICATED BY ANNOTATED SYMBOLS; BY KEY NOTES; BY NOTES ON PLANS, ELEVATIONS, OR DETAILS; OR BY UNIQUE DIMENSIONS ON ELEVATIONS OR DETAILS.
C. MOUNTING CONFIGURATION DIAGRAMS ARE ELEVATIONS WHICH ILLUSTRATE TYPICAL RULES GOVERNING THE RELATIONSHIPS BETWEEN, AND PLACEMENT OF, ITEMS WHICH OCCUR IN GROUPS OF RELATED ITEMS OR IN CLOSE PROXIMITY TO OTHER PARTS OF THE WORK (SUCH AS SWITCHES AND DOOR FRAMES). UNLESS OTHER MOUNTING CONFIGURATIONS ARE SPECIFICALLY NOTED, DIMENSIONED, OR ELEVATED, THE TYPICAL RELATIONSHIPS, ARRANGEMENTS, AND THE TYPICAL CONFIGURATION DIAGRAMS APPLY THROUGHOUT THE WORK OF THIS PROJECT.
TOILET
ACCESSORIES
(AS SPECIFIED)
3'
- 4
1'
- 6
2'
- 9
3'
- 4
"4'
- 1
0"
8" 1'
- 0
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. VA CONTRACT NO.
AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ 70-129AREAG70-131AREAH AREAM70-139AREAA70-11770-121AREACAREAL70-13770-119AREAB70-123AREAD70-135AREAK70-127AREAF70-125AREAE70-133AREAJ70-129AREAG70-131AREAH
C U s e rs \l h o ff m a n
\D o c u m e n ts
\6
A rc h (C e n tr a l2 lh o ff m a n N
X Y
V .r v t
/1
/2
:2
:2
P
M
09/07/2021
ARCHITECTURAL - TYPICAL DETAILS EHRM Training and Admin Space Support
Minneapolis VA Healthcare System
DA LH
618-701
1384-A512
ISSUE FOR BID
18-11636C26319D0022
12" = 1'-0"
TRANSITION STRIPS
6" = 1'-0"
CORNER GUARD WP-2
6" = 1'-0"
END WALL PROTECTOR WP-3
6" = 1'-0"
INTEGRATED COVE BASE
1 1/2" = 1'-0"
BACKING PLATE DETAIL
1 1/2" = 1'-0"
FEC FULLY RECESSED TYP.
1/2" = 1'-0"
ANCHORAGE DETAIL
3" = 1'-0"
HANDRAIL DETAIL
3/8" = 1'-0"
TYPICAL TOILET ROOM DETAILS
Revisions: Date:
65% Design Development Submittal 07/15/2021
11"
SS-3
60 MIL RUBBER MEMBRANE ON 3/4" PLYWOOD.
MECHANICALLY ATTACH PLYWOOD STUD WALL.
WRAP RUBBER MENRANE UNTER QUARTZ SILL.
1' - 1"
1/
2" 3'
- 0
/4
3-5/8" METAL STUD FRAMING 16"
O.C. W/ 60 MIL RUBBER
MEMBRANE ON 3/4" PLYWOOD.
CONTINUE MEMBRANE UNDER
SIL.
1'
- 0
SEALANT
4"
3-5/8" METAL STUD FRAMING, 16" O.C.
SS-3
WP-1
VB-2
WP-3
8" METAL STUD FRAMING,
16" O.C. W/(2) LAYERS 5/8"
GYP. BD.
LEVEL 3
37' - 4"
BTM OF DECKING
34' - 11 1/2"
DECKING ASSEMBLY -
REFER TO SHEET 1384-A103
8" METAL STUD WALL W/ SOUNT
ATTENUATING BATT
INSULATION, (2) LAYERS OF 5/8"
GYP. BD. - PAINTED, BOTH
SIDES
SS-3 ON 3/4" PLYWOOD
3'
- 6
LEVEL 3
37' - 4"
LEVEL 3
37' - 4"
LEVEL 3
37' - 4"
BTM OF DECKING
34' - 11 1/2"
LEVEL 3
37' - 4"
DECKING ASSEMBLY
REFER TO SHEET 1384-A103
3-5/8"" METAL STUD FRAMING, 16" O.C.
W/ 5/8" GYP BD.-PAINTED
22 GA METAL LINER. OVERLAP
SEAMS IN DIRECTION OF AIR FLOW
(UPWARD)
EXISTING COLUMN ENCLOSURE TO REMAIN.
EXISTING CONSTRUCTION:
• 3/4" PLASTER ON METAL LATHE
• 6" 20 GA. STUDS @ 12" O.C.-
• NO RUNNERS
• 22 GA. SHEET METAL LINER SCREWED
TO STUDS
EXISTING ALUMINUM LINEAR
GRILLE REINSTALLED
5/8" GYP BD - PAINTED
CORNER BEAD
LEVEL 2
18' - 8"
EXISTING KNEE WALL TO REMAIN
EXISTING ALUMINUM GRILLE - CONTRACTOR TO MODIFY PER NEW WALL LAYOUT
EXISTING COLUMN ENCLOSURE TO REMAIN.
EXISTING CONSTRUCTION:
• 3/4" PLASTER ON METAL LATHE
• 6" 20 GA. STUDS @ 12" O.C.-
• NO RUNNERS
• 22 GA. SHEET METAL LINER SCREWED TO STUDS
LINE OF WALL BEYOND
SS-3
60 MIL RUBBER MEMBRANE ON 3/4" PLYWOOD.
MECHANICALLY ATTACH PLYWOOD TO EXISTING
PLASTER KNEE WALL.
WRAP RUBBER MENRANE UNTER QUARTZ SILL.
7 1/4"
1/
2"
2'
- 4
3-5/8" METAL STUD FRAMING 16" O.C. W/
60 MIN RUBBER MEBRANE ON 3/4" PLYWOOD
LEVEL 3
37' - 4"
BTM OF DECKING
34' - 11 1/2"
10 1/4"
1/
2"
DECKING ASSEMBLY -
REFER TO SHEET 1384-A103
8" METAL STUD FRAMING, 16" O.C.
W/ (2) LAYERS 5/8" GYP BD.-
PAINTED
22 GA METAL LINER. OVERLAP SEAMS IN
DIRECTION OF AIR FLOW (UPWARD)
EXISTING COLUMN ENCLOSURE TO REMAIN.
EXISTING CONSTRUCTION:
• 3/4" PLASTER ON METAL LATHE
• 6" 20 GA. STUDS @ 12" O.C.-
• NO RUNNERS
• 22 GA. SHEET METAL LINER SCREWED
TO STUDS
NEW ALUMINUM LINEAR GRILLE
5/8" GYP BD - PAINTED
CORNER BEAD
LEVEL 3
37' - 4"
BTM OF DECKING
34' - 11 1/2"
EXISTING ATRIUM WALL
NEW DUCT WORK -
REFER TO MECHANICAL
DRAWINGS
PROVIDE BACKER ROD AND
SEALANT WHERE NEW ENCLOSURE
MEETS EXISTING WALL
DECKING ASSEMBLY -
REFER TO SHEET 1384-A103
CORNER BEAD
3-5/8" METAL STUD FRAMING
@ 16" O.C. W/ 5/8" GYP. BD. -
PAINTED TYP.
3-5/8" METAL STUD FRAMING @ 16"
O.C. W/ 5/8" GYP. BD. - PAINTED TYP.
5'
- 6
LEVEL 3
37' - 4"
BTM OF DECKING
34' - 11 1/2"
EXISTING ATRIUM WALL
NEW MECAHANICAL
DUCT WORK - REFER TO
MECHANICAL
DRAWINGS
NEW MECHANICAL PIPING -
REFER TO MECHANICAL
DRAWINGS.
NEW 2-10" W X 4'-0" H LOUVER
6" METAL STUD FRAMING, 16"
O.C. W/ 5/8" GYP. BD -
PAINTED
DECKING ASSEMBLY
REFER TO SHEET 1384-A103
22 GA SHEET METAL LINER
OVERLAP SEAMS IN
DIRECTION OF AIRFLOW
(DOWNWARD).
6" METAL STUD FRAMING, 16"
O.C. W/ 5/8" GYP. BD -
PAINTED
ATTACH LINER TO
TOP OF DECKING
ROOF DECK
74' - 8"
EXISTING PILASTER CAPITAL AND
CORNICE BETWEEN COLUMN GRIDS
BB, AA & Z
3-5/8" METAL STUD FRAMING
AND BRACING 16" O.C.
CONTINUE PROFILE ALONG
NORTH ATRIUM WALL BETWEEN
COLUMN GRIDS BB, AA & Z
5/8" GYP BD. -
PAINTED
1' - 0 3/4" 1' - 1 1/4" 1' - 2 1/4"
3'
- 7
9"
NEW DUCTWORK - REFER TO
MECHANICAL DRAWINGS
2-1/2" METAL STUD FRAMING,
16" O.C. W/ 1/2" GYP BD. -
PAINTED
6" METAL STUD FRAMING W/ 5/8" GYP BD. - PAINTED
L 4X4X3/8 BRACING - TIE INTO
EXSTING EMBEDDED ANGLE
L4X4X3/8
L 4X4X3/8 BRACING - TIE INTO EXSTING BENT PLATE
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management