Attachment 3 - 531-22-103 CDV2 Drawings.pdf

PDF 32 MB Posted

Attached to
Y1LZ--531-22-103 | Add Parking on Parade Grounds | Boise VA Medical Center
Solicitation number
36C26026R0046
Issued by

About this file

This file is a set of construction drawings (Attachment 3: CDV2 Drawings) for the Add Parking on Parade Grounds project at Boise VA Medical Center in Boise, Idaho (Project No. 531-22-103). The drawings comprise 22 sheets of detailed construction documents prepared by Spees Design Build (architect/engineer of record) with civil engineering by KPFF, landscape design by Russell Design Source, and electrical engineering by LC Engineers. The project involves constructing a new 110-space parking lot on the parade grounds, including paved surface with asphalt and concrete curbing, storm drainage infrastructure with catch basins and a 1,000-gallon sedimentation tank, irrigation systems, landscape plantings, and electrical site lighting. Key construction elements include temporary erosion and sediment control measures, demolition of existing site features, grading and drainage plans with storm drain pipes ranging from 6 to 8 inches, parking stall layout at 9'x18' dimensions with accessible spaces, and connection to existing electrical infrastructure in Building 79.

The construction documents include detailed specifications for site preparation, materials, and installation standards. Critical coordination requirements noted throughout include field verification of existing conditions before work begins, protection of existing utilities (particularly a US West direct-buried cable), coordination with a concurrent Primary Care Facility project (No. 531-325) that shares certain storm drain infrastructure, and maintenance of existing irrigation systems in protected areas. The contractor must verify benchmark locations, construction baseline coordinates, and all horizontal control test points prior to commencing work. Landscape improvements include native and drought-tolerant plantings such as river birch, European hornbeam, magnolia, and various shrubs and ground covers. Electrical work includes new parking lot lighting tied to existing Panel 1 Circuit 3 in Building 79, with conduit and handhole installations specified for both power and surveillance systems.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AC

AC AC

AC

C

ES

S

R O

AD

OFFICER ROW (ONE WAY)

EAST VA LOOP(ONE

WAY)<

C

OLLIN

S

ROAD

U N

IO

N

S

TR

EE

T (O N E W

AY

R V

R V

FUEL TANK

LOCATION

T110

T121

FR

E

ES

TO

N E

C R E E K

T124

BOISE SCHOOL PROPERTYM

O U N

TAIN

C O

VE

R D

STATE OFIDAHOVETERANSHOME

R O B B

IN

S

R O A D

FORTSTREET

HAYS

STREET

F

IF

T H

S T R E E T

M M

M

M M

ABA

ND

ON

ED

STEA

M

VAU

LT

T116

T119

WATER SYSTEM

ABANDONED

ABANDONED

ROUNDRESERVOIR

ARCHITECTURAL

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

PHONE: (206) 590-2118

DESIGN TEAM

CIVIL

KPFF

LANDSCAPE

RUSSEL DESIGN SOURCE

ELECTRICAL

LC ENGINEERS

421 PARKCENTER BLVD #200

BOISE, ID, 83706

PHONE: (208) 546-9757

1388 N. BIZTOWN LOOP

HAYDEN, ID, 83835

PHONE: (208) 670-8086

248 4TH ST, #501

BREMERTON, WA, 98337

PHONE: (360) 940-0745

PROJECT INFORMATION

STATE: IDAHO

COUNTY: ADA

OWNER: BOISE VA MEDICAL CENTER

500 W FORT ST, BOISE, ID, 83702

INFORMATION APPLICABLE BUILDING

SITE: PARKING LOT

GENERAL NOTES

1. COORDINATE WORK WITH ALL CONTRACT DOCUMENTS, INCLUDING BUT NOT LIMITED TO DRAWINGS &

SPECIFICATIONS.

2. SPECIFICATIONS SHALL SUPERSEDE DRAWINGS IN THE CASE OF ANY CONFLICTING INFORMATION.

VERIFY WITH VA COR BEFORE PROCEEDING.

3. THE CONTRACTOR AND ANY SUB CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND PROJECT REQUIREMENTS PRIOR TO SUBMITTING A BID OR BEGINNING WORK. NO ALLOWANCES WILL BE MADE ON BEHALF OF THE CONTRACTOR OR SUB-CONTRACTORS FOR FAILURE

TO VISIT THE SITE.

4. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS BEFORE BEGINNING WORK. ANY CONFLICTS BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS SHALL BE BROUGHT

IMMEDIATELY TO THE ATTENTION OF THE COR.

5. ALL WORK SHALL BE PERFORMED WITH A HIGH-LEVEL OF WORKMANSHIP.

6. THE CONTRACTOR SHALL VERIFY ALL PRODUCT TYPES AND QUANTITIES DURING SITE WALK

THROUGH, PRIOR TO PURCHASING ANY MATERIALS, EQUIPMENT, PRODUCTS OR LABOR.

7. THE CONTRACTOR SHALL VERIFY AND COORDINATE WITH ALL INSTALLERS TO ENSURE COMPLIANCE

WITH THE CONTRACT DOCUMENTS.

VA BOISE MEDICAL CENTER - BOISE, ID

85A

T110

54 33

T122

T123T124

T11748

T111

NEW PARKING LOT #15

BOISE VA MEDICAL CENTER, BOISE ID

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

G-001

COVER & DRAWING INDEX

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

ADD PARKING ON PARADE

GROUNDS

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

07/01/2021 MK AJ

CONSTRUCTION

DOCUMENTS

ADD PARKING

ON PARADE GROUNDS

BOISE VA MEDICAL CENTER - BOISE, ID

PROJECT #: 531-22-103

TRUE

NORTH

DRAWING INDEX

PAGE # SHEET # SHEET NAME

GENERAL

001 OF 22 G-001 COVER & DRAWING INDEX

002 OF 22 GS101 ARCHITECTURAL SITE PLAN & SIGNAGE

CIVIL

003 OF 22 C-100 CIVIL COVER SHEET

004 OF 22 CG200 TEMPORARY EROSION & SEDIMENT CONTROL PLAN

005 OF 22 CG210 TEMPORARY EROSION & SEDIMENT CONTROL DETAILS

006 OF 22 CD300 DEMOLITION PLAN

007 OF 22 CG400 GRADING & STORM DRAINAGE PLAN

008 OF 22 CG410 STORM DRAIN PROFILES

009 OF 22 CG420 STORM DRAINAGE DETAILS

010 OF 22 CG421 STORM DRAINAGE DETAILS

011 OF 22 CP422 STORM DRAINAGE DETAILS

012 OF 22 CP500 PAVING & HORIZONTAL CONTROL PLAN

013 OF 22 CP510 PAVING DETAILS

LANDSCAPE

014 OF 22 LS101 LANDSCAPE PLAN

015 OF 22 LS102 LANDSCAPE DETAILS

016 OF 22 LI101 IRRIGATION DEMO PLAN

017 OF 22 LI102 DIAGRAMMATIC IRRIGATION PLAN

018 OF 22 LI103 IRRIGATION DETAILS

ELECTRICAL

019 OF 22 E-001 GENERAL NOTES, ABBREVIATIONS, AND LEGENDS

020 OF 22 ES100 SITE ELECTRICAL PLAN

021 OF 22 E-501 ELECTRICAL DETAILS

022 OF 22 E-601 ELECTRICAL SCHEDULES

LOCATION PLAN

Revisions: Date:

VICINITY MAP

PROJECT

NORTH

cjaim Image cjaim Callout

AC

AC AC

T112

T113

SURVEY POINT

SURVEY POINT

NEW PARKING LOT #15

BUILDING

BUILDING

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

T111

BUILDING

N O

R T

H V

A L

O O

P

127'

REFERENCE CIVIL PLANS FOR

MORE DETAILED INFORMATION

SURVEY POINT

SURVEY POINT

PL-12.01-02

PL-12.01-01

60'60' 6'

PL-12.02-01

LIMITS OF SITE DISTURBANCE FOR

CONSTRUCTION OF PARKING LOT

T Y

P

P

LOT # 15

PATIENT PARKING

2'

/2

/4

0' - 1 3/4"

2' - 0"

1 1/2"

/2

"2

/2

3"

Notice Motor vehicles parked in Red zones, zones, reserved ?

spaces or in violation of V.A.

parking regulations, will be towed at owner's expense.

Vehicle Code. Sec. 1234567?

Police Dept. 555-5555

Persons entering government property must consent upon request, to the inspection of all packages, luggage and containers in their posession.

Refusal to consent to inspections is basis for denial of admission.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

GS101

ARCHITECTURAL SITE PLAN &

SIGNAGESPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

ADD PARKING ON PARADE

GROUNDS

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

MK MA/AJ

CONSTRUCTION

DOCUMENTS

PROJECT

NORTH

1" = 40'-0"

ARCHITECTURAL SITE PLAN

Revisions: Date:

GENERAL NOTES

1. ALL WORK TO BE COMPLETED IN ONE PHASE.

2. COORDINATE CONTRACTORS STORAGE LOCATION AT THE

PRE-CONSTRUCTION MEETING WITH COR. THIS INCLUDES,

BUT IS NOT LIMITED TO, AREAS TO BE USED FOR MATERIAL

STORAGE, ACCESS FOR MATERIAL DELIVERIES AND

TRANSPORTATION ROUTES TO THE PROJECT AREA.

3. ENSURE COMPLIANCE WITH ALL NECESSARY CONTRACT

DOCUMENTS REGARDING CONTRACTOR STORAGE AREA.

4. DO NOT STORE MATERIALS, TOOLS, EQUIPMENT OR

VEHICLES IN ANY LOCATION ON MEDICAL CENTER

PROPERTY UNLESS GIVEN PRIOR VA APPROVAL BY THE

COR.

1 1/2" = 1'-0"

PL-12.01- PARKING IDENTIFICATION SIGN POST AND PANEL

SIGNAGE MESSAGE SCHEDULE

SIGN ID ROOM # MESSAGE NOTES

PL-12.01 - PARKING LOT ID POST AND PANEL

PL-12.01-01 NA SEE ENLARGED DRAWING

PL-12.01-02 NA SEE ENLARGED DRAWING

PL-12.04 - HANDICAPPED PARKING STALL

PL-12.02-01 N/A SEE ENLARGED DRAWING

1 1/2" = 1'-0"

PL-12.02 - POST AND PANEL

cjaim Image

Snapshot

E

W

W

SD SD SD

SS SS

BM-#4

BM-#6

BM-#5

N

5°

'2 1"

E

N V

A H

O S

PI

TA

L

LO

O

P

APPROXIMATE

LIMITS

OF WORK

STA. 20+00.00, 0.00'

BENCHMARK #5

FOUND BRASS CAP

N:712713.54

E:2507465.30

EL:2724.86

STA. 21+00.29, 0.87' RT

BENCHMARK #6 (TEST POINT)

FOUND BRASS CAP

N:712632.83

E:2507405.76

EL:2724.56

FIRE FIRE

W W W

E E E

T T T

CIVIL ABBREVIATIONS (PROPOSED)

BC BOTTOM OF CURB

CB CATCH BASIN

CONC CONCRETE

COR CONTRACTING OFFICER REPRESENTATIVE

DIA DIAMETER

DWG DRAWING

E EAST

EL ELEVATION

EX EXISTING

FT FEET

ID INNER DISTANCE

IE INVERT ELEVATION

ISPWC IDAHO STANDARDS FOR PUBLIC WORKS

CONSTRUCTION

LF LINEAR FEET

MAG MAGNETIC

MAX MAXIMUM

MFG MANUFACTURING

MIN MINIMUM

N NORTH

NO. NUMBER

NTS NOT TO SCALE

OD OUTER DISTANCE

OZ OUNCES

PE POLYETHYLENE

PERF PERFORATED

PVC POLYVINYL CHLORIDE

R RADIUS

S SOUTH

SD STORM DRAIN

SDCO STORM DRAIN CLEAN-OUT

SDMH STORM DRAIN MAINTENANCE HOLE

SQ SQUARE

STD STANDARD

STL STEEL

TC TOP OF CURB

TESC TEMPORARY EROSION AND SEDIMENT CONTROL

TYP TYPICAL

VA UNITED STATES DEPARTMENT OF VETERANS'

AFFAIRS

W WEST

YD YARDS

VERTICAL DATUM (PER PROJECT SURVEY)

NAVD 88 (GEOID18)

HORIZONTAL DATUM (PER PROJECT SURVEY)

NAD 83 (2011)

BENCHMARKS (PER PROJECT SURVEY)

LEGAL DESCRIPTION (BRIEF) (PER PROJECT SURVEY)

EXISTING LEGEND (PER PROJECT SURVEY)

FIRE HYDRANT

WATER OR STEAM VALVE

WATER BLOW-OFF

POST INDICATOR VALVE

SANITARY SEWER MANHOLE

SANITARY SEWER CLEAN-OUT

STORM DRAIN DROP INLET

SAND & GREASE TRAPS

STREET LIGHT

ELECTRICAL MANHOLE

ELECTRICAL JUNCTION BOX

ELECTRICAL GROUNDING ROD

IRRIGATION BOX/VALVES

SIGN

PROJECT BENCHMARK

CONIFEROUS TREE

DECIDUOUS TREE

STORM DRAIN LINE

SANITARY SEWER LINE

FIRE LINE

WATER LINE

ELECTRICAL LINE

COMMUNICATION LINE

ROAD CROWN/CENTERLINE

CURB & GUTTER

SIDEWALK

C-100

CIVIL COVER SHEET

LOCATED IN SW 14 OF SECTION 02, TOWNSHIP 3 NORTH, RANGE 2

EAST, B.M., CITY OF BOISE, ADA COUNTY, IDAHO

# 1 - MAG SPIKE

NORTHING: 712885.38

EASTING: 2507693.57

EL: 2725.07

#2 - MAG NAIL

NORTHING: 712562.09

EASTING: 2507823.15

EL: 2726.93

#4 - MAG SPIKE

NORTHING: 712156.40

EASTING: 2507434.00

EL: 2726.39

#5 - BRASS CAP

NORTHING: 712713.54

EASTING: 2507465.30

EL: 2724.86

#6 - BRASS CAP

NORTHING: 712632.83

EASTING: 2507405.76

EL: 2724.56

CONSTRUCTION BASELINE EQUATION

SCALE 1" = 80'

1. CONSTRUCTION BASELINE IS DEFINED AS A LINE BEARING

N35°55'21"E THROUGH BENCHMARK #5.

2. PRIOR TO COMMENCING WORK, LOCATE ALL HORIZONTAL

CONTROL TEST POINTS FROM THE CONSTRUCTION

BASELINE. IF TEST POINTS ARE NOT AT STATION/OFFSET

SHOWN, CONTACT ENGINEER OF RECORD IMMEDIATELY.

CONSTRUCTION SHALL NOT PROCEED UNTIL THE

CONSTRUCTION BASELINE AND HORIZONTAL CONTROL TEST

POINTS HAVE BEEN LOCATED AS SHOWN.

CONSTRUCTION BASELINE NOTES

R

Call 811 two business days before you dig

CONSTRUCTION

DOCUMENTS

ADD PARKING ON PARADE

GROUNDS

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

JCG CM

Revisions: Date:

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

PROJECT

NORTH

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

G R

AS

S

AR

EA

G R

AS

S

AR

EA

AS

PH

AL

T

ASPHALT

BM-#6

BM-#5

S&G TRAP

RIM (NE): 2724.41

INV.IN(NW) -3.75 - 12"

RIM (SW): 2724.36

INV.OUT (NW):-4.05 - 12"

INLET

GRATE: 2723.28

INV.IN:-2.10 - 12"

INV.OUT:-2.40 - 12"

INLET

GRATE: 2723.15

INV.IN & OUT:-2.00

STORM DRAIN MANHOLE

RIM: 2723.50

INV. IN (NE&SE):-3.55

INV.OUT (SW):-3.55

S&G TRAP

RIM (NE): 2723.91

INV.IN(NW) -3.10 - 12"

INLET

GRATE: 2723.01

INV.IN:-1.80 - 12"

INV.OUT:-2.00 - 12"

INLET

GRATE: 2722.97

INV.IN & OUT:-1.90 - 12"

STORM DRAIN MANHOLE

RIM: 2723.22

INV. IN (NE&SE):-3.40 - 12"

INV.OUT (SW):-3.40 - 12"

BENCH MARK #6

N: 712632.83

E: 2507405.76

EL: 2724.56

BRASS CAP

BENCH MARK #5

N: 712713.54

E: 2507465.30

EL: 2724.86

BRASS CAP

N O

R

TH

V A H

O S

PI

TA

L

LO

O

P R O

A D

TEMPORARY STABILIZED

CONSTRUCTION

ENTRANCE

TEMPORARY CONSTRUCTION

FENCE ENTRANCE GATE

APPROXIMATE LIMITS

OF WORK (TYP)

FILTER FABRIC

SILT FENCE

(TYP)

CATCH BASIN/INLET

PROTECTION (TYP)

CG210

CG210

CG210

TEMPORARY ORANGE PLASTIC

CONSTRUCTION FENCE

(TYP)

APPROXIMATE LOCATION OF

US WEST DIRECT BURIED

CABLE. SEE NOTE 12.

M

EX SEEPAGE BED FOR PRIMARY

CARE FACILITY PROJECT TO REMAIN

(UNDER SEPARATE CONTRACT,

PROJECT NO. 531-325)

R

Call 811 two business days before you dig

CONSTRUCTION

DOCUMENTS

ADD PARKING ON PARADE

GROUNDS

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

JCG CM

Revisions: Date:

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

1 inch = 20 feet

10 20 40

CG200

TEMPORARY EROSION &

SEDIMENT CONTROL PLAN

LEGEND

APPROXIMATE LIMITS OF WORK

FILTER FABRIC SILT FENCE

TEMPORARY ORANGE PLASTIC

CONSTRUCTION FENCE

CATCH BASIN/INLET

PROTECTION

TEMPORARY STABILIZED

CONSTRUCTION ENTRANCE

TEMPORARY CONSTRUCTION

FENCE ENTRANCE GATE

TESC NOTES

1. THE EROSION AND SEDIMENT CONTROL FACILITIES SHOWN

ON THIS PLAN ARE THE MINIMUM REQUIREMENTS FOR

ANTICIPATED SITE CONDITIONS. DURING THE

CONSTRUCTION PERIOD, THESE FACILITIES SHALL BE

UPGRADED (E.G. ADDITIONAL PUMPS, RELOCATION OR

ADDITION OF DITCHES, SILT FENCES, ETC.) BY THE

CONTRACTOR AS NEEDED FOR UNEXPECTED STORM EVENTS

AT NO ADDITIONAL COST TO THE VA.

2. MONITOR DISCHARGE FLOW AND WATER QUALITY OF

DISCHARGE INTO STORM DRAIN TO ENSURE COMPLIANCE

WITH THE VA TURBIDITY DISCHARGE REQUIREMENTS.

3. ALL EROSION AND SEDIMENT CONTROL FACILITIES SHOWN

ON THIS PLAN MUST BE CONSTRUCTED IN CONJUNCTION

WITH ALL CLEARING, GRADING, AND EXCAVATION

ACTIVITIES IN SUCH A MANNER AS TO INSURE THAT

SEDIMENT LADEN WATER DOES NOT LEAVE THE SITE.

4. ALL EROSION AND SEDIMENT CONTROL FACILITIES SHALL

BE INSPECTED DAILY BY A CERTIFIED EROSION CONTROL

LEAD, AND MAINTAINED AS NECESSARY OR AS DIRECTED BY

THE VA TO ENSURE THEIR CONTINUED FUNCTIONING.

5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE

INSTALLED AT THE BEGINNING OF CONSTRUCTION AND

MAINTAINED UNTIL NO LONGER NECESSARY. ADDITIONAL

MEASURES MAY BE REQUIRED TO INSURE THAT ALL PAVED

AREAS ARE KEPT CLEAN FOR THE DURATION OF THE

PROJECT.

6. PROVIDE CONSTRUCTION FENCING AS REQUIRED FOR

SAFETY AND AS DIRECTED BY THE COR.

7. NO SEDIMENT SHALL BE TRACKED ONTO PAVED STREETS OR

ROADWAYS. THE CONTRACTOR SHALL EMPLOY EMERGENCY

MEASURES TO REMOVE SEDIMENT FROM PAVED SURFACES,

AS NEEDED. SEDIMENT TRACKED ONTO PAVED SURFACES

SHALL NOT BE WASHED INTO STORM DRAINS OR OTHER

UTILITY INLETS.

8. PROVIDE INLET PROTECTION TO ALL DOWNSTREAM INLETS

AND CATCH BASINS WITHIN 500 FEET OF THE JOB SITE.

9. MAINTAIN INLET PROTECTION FOR ALL ON-SITE INLETS

UNTIL CONNECTED STORM DRAIN INFRASTRUCTURE IS

FULLY DEMOLISHED AND DISCONNECTED FROM THE SYSTEM.

10. UPON FINAL COMPLETION OF THE PROJECT, ALL EROSION

AND SEDIMENT CONTROL FACILITIES SHALL BE REMOVED BY

THE CONTRACTOR. CARE SHALL BE TAKEN TO AVOID

SEDIMENT FROM ENTERING THE DRAINAGE SYSTEM DURING

THE REMOVAL PROCESS.

11. REFER TO ARCHITECTURAL SITE PLAN GS101 FOR

INFORMATION ABOUT CONTRACTOR STAGING AND PARKING

AREAS.

12. CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF THE

US WEST DIRECT BURIED CABLE AND PROTECT IT IN PLACE

DURING CONSTRUCTION. NOTIFY THE ENGINEER OF RECORD

IF THE FIELD LOCATION OF THE CABLE CONFLICTS WITH

PROPOSED IMPROVEMENTS.

PROJECT

NORTH

OVERFLOW (TO BYPASS

PEAK STORM VOLUMES)

EXCEPT MAY BE REDUCED TO

50' MIN FOR SITES WITH LESS THAN

4" TO 8" QUARRY SPALLS

EXISTING ROAD R=25'

INGRESS / E

GRESS AREA

15' M

IN

PROVIDE FU

LL

WIDTH OF

M

IN

AS REQUIRED 100' MIN

ONE ACRE OF EXPOSED SOIL

TYPICAL CROSS SECTION

3'2' M

IN

2"X2"X14 GAUGE WIRE

FABRIC, OR EQUIVALENT,

IF STANDARD STRENGTH

FABRIC USED

BACKFILL TRENCH WITH

NATIVE SOIL MATERIAL OR

3/4" TO 1-1/2" WASHED

GRAVEL.

NEWLY GRADED

OR DISTURBED

SOILS

MIN 4"X4" TRENCH

BURY BOTTOM OF FILTER

FABRIC MATERIAL WITH

EXCAVATED MATERIAL

2"X4" WOOD POSTS, STEEL

FENCE POSTS, REBAR, OR

EQUIVALENT.

6' MAX SPACING

EXISTING GRADE OR

UNDISTURBED SOILS

12"

MIN

PROJECT SITE

ORANGE PLASTIC

CONSTRUCTION FENCE

FILTER FABRIC

FILTER FABRIC SILT FENCE

NTS

CG210

TEMPORARY STABILIZED CONSTRUCTION ENTRANCE

NTS

CG210

CATCH BASIN/INLET PROTECTION

NTS

CG210

R

Call 811 two business days before you dig

CONSTRUCTION

DOCUMENTS

ADD PARKING ON PARADE

GROUNDS

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

JCG CM

Revisions: Date:

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

CG210

TEMPORARY EROSION &

SEDIMENT CONTROL DETAILS

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SEWER MANHOLE

G R

AS

S

AR

EA

G R

AS

S

AR

EA

AS

PH

AL

T

ASPHALT

BM-#6

BM-#5

S&G TRAP

RIM (NE): 2724.41

INV.IN(NW) -3.75 - 12"

RIM (SW): 2724.36

INV.OUT (NW):-4.05 - 12"

INLET

GRATE: 2723.28

INV.IN:-2.10 - 12"

INV.OUT:-2.40 - 12"

INLET

GRATE: 2723.15

INV.IN & OUT:-2.00

STORM DRAIN MANHOLE

RIM: 2723.50

INV. IN (NE&SE):-3.55

INV.OUT (SW):-3.55

S&G TRAP

RIM (NE): 2723.91

INV.IN(NW) -3.10 - 12"

RIM (SW): 2723.91

INV.OUT (NW):-3.65 - 12"

INLET

GRATE: 2723.01

INV.IN:-1.80 - 12"

INV.OUT:-2.00 - 12"

INLET

GRATE: 2722.97

INV.IN & OUT:-1.90 - 12"

STORM DRAIN MANHOLE

RIM: 2723.22

INV. IN (NE&SE):-3.40 - 12"

INV.OUT (SW):-3.40 - 12"

INLET

GRATE: 2723.14

INV.OUT:-2.10 - 12"

BENCH MARK #6

N: 712632.83

E: 2507405.76

EL: 2724.56

BRASS CAP

BENCH MARK #5

N: 712713.54

E: 2507465.30

EL: 2724.86

BRASS CAP

N O

R

TH

V A H

O S

PI

TA

L

LO

O

P R O

A D

REMOVE EXISTING

TREE (TYP)

APPROXIMATE LIMITS

OF WORK

APPROXIMATE LOCATION

OF US WEST DIRECT

BURIED CABLE.

SEE NOTE 12.

M

EX SDMH TO REMAIN FOR PRIMARY

CARE FACILITY PROJECT

(UNDER SEPARATE CONTRACT,

PROJECT NO. 531-325)

EX CATCH BASIN TO REMAIN FOR

PRIMARY CARE FACILITY PROJECT

(UNDER SEPARATE CONTRACT,

PROJECT NO. 531-325)

EX CATCH BASIN TO REMAIN FOR

PRIMARY CARE FACILITY PROJECT

(UNDER SEPARATE CONTRACT,

PROJECT NO. 531-325)

EX SEEPAGE BED TO REMAIN FOR

PRIMARY CARE FACILITY PROJECT

(UNDER SEPARATE CONTRACT,

PROJECT NO. 531-325)

R

Call 811 two business days before you dig

CONSTRUCTION

DOCUMENTS

ADD PARKING ON PARADE

GROUNDS

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

JCG CM

Revisions: Date:

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

1 inch = 20 feet

10 20 40

CD300

DEMOLITION PLAN

1. SEE SHEET C-100 FOR ABBREVIATIONS AND LEGEND.

2. PROTECT IN PLACE ALL UNDERGROUND UTILITIES AND

ASSOCIATED STRUCTURES WITHIN THE LIMIT OF WORK

UNLESS NOTED OTHERWISE.

3. DEMOLISH ALL EXISTING SURFACE FEATURES WITHIN THE

LIMIT OF WORK UNLESS NOTED OTHERWISE. PROTECT THE

SURFACE PARKING LOT WITHIN THE BID ALTERNATIVE 1

LIMITS OF WORK IF IT HAS BEEN CONSTRUCTED EARLIER

UNDER A SEPARATE CONTRACT FOR PROJECT NO. 531-325.

4. PROTECT IN PLACE ALL UTILITIES AND SURFACE FEATURES

OUTSIDE THE LIMIT OF WORK.

5. CONTRACTOR SHALL WALK THE SITE WITH THE COR PRIOR

TO CONSTRUCTION TO VERIFY LIMITS OF SITE

DISTURBANCE AND EXISTING FEATURES, UTILITIES, AND

STRUCTURES TO BE PROTECTED.

6. MAKE VERTICAL SAWCUTS BETWEEN EXISTING PAVEMENT

TO REMAIN AND PAVEMENT TO BE REMOVED. PROTECT IN

PLACE PAVEMENT OUTSIDE SAWCUT LINE.

7. PROVIDE CONSTRUCTION FENCING, SIGNAGE, AND

BARRIERS AS REQUIRED TO PREVENT UNAUTHORIZED

ACCESS INTO THE DEMOLITION AREA.

8. REFER TO ELECTRICAL PLANS FOR INFORMATION ON

PROTECTION AND REMOVAL OF EXISTING ELECTRICAL

INFRASTRUCTURE.

9. CONTRACTOR SHALL REMOVE ALL DEMOLITION DEBRIS

FALLING OUTSIDE THE LIMIT OF WORK IMMEDIATELY.

10. CONTRACTOR SHALL DISPOSE OF ALL DEMOLITION

MATERIAL OFF-SITE IN A SAFE AND LEGAL MANNER AT NO

ADDITIONAL EXPENSE TO THE OWNER.

11. CONTRACTOR SHALL REMOVE TREES AS SHOWN ON PLAN.

FULLY REMOVE STUMP AND ROOTS.

12. CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF THE

US WEST DIRECT BURIED CABLE AND PROTECT IT IN PLACE

DURING CONSTRUCTION. NOTIFY THE ENGINEER OF RECORD

IF THE FIELD LOCATION OF THE CABLE CONFLICTS WITH

PROPOSED IMPROVEMENTS.

SITE DEMOLITION NOTES

LEGEND

APPROXIMATE LIMITS OF WORK

REMOVE EXISTING TREE

DEMOLISH EXISTING CURB

FLAG NOTES

1 PROTECT CURB EAST AND WEST OF THE SAWCUT AREA

MARKED. SEE NOTE 6 ABOVE.

PROTECT EXISTING STREET LIGHT AND ANY ASSOCIATED

CONDUITS.

DEMOLISH EXISTING CURB.

PROTECT EXISTING TREE.

PROJECT

NORTH

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SEWER MANHOLE

INV. IN

(S

E):-7 .17 - 8

INV. IN

(N

E):-7 .19 - 8

INV.OUT (N

W):-7

.20 - 8

G R

AS

S

AR

EA

G R

AS

S

AR

EA

AS

PH

AL

T

ASPHALT

BM-#6

BM-#5

S&G TRAP

RIM (NE): 2724.41

INV.IN(NW) -3.75 - 12"

RIM (SW): 2724.36

INV.OUT (NW):-4.05 - 12"

INLET

GRATE: 2723.28

INV.IN:-2.10 - 12"

INV.OUT:-2.40 - 12"

INLET

GRATE: 2723.15

INV.IN & OUT:-2.00

STORM DRAIN MANHOLE

RIM: 2723.50

INV. IN (NE&SE):-3.55

INV.OUT (SW):-3.55

S&G TRAP

RIM (NE): 2723.91

INV.IN(NW) -3.10 - 12"

RIM (SW): 2723.91

INV.OUT (NW):-3.65 - 12"

INLET

GRATE: 2723.01

INV.IN:-1.80 - 12"

INV.OUT:-2.00 - 12"

INLET

GRATE: 2722.97

INV.IN & OUT:-1.90 - 12"

STORM DRAIN MANHOLE

RIM: 2723.22

INV. IN (NE&SE):-3.40 - 12"

INV.OUT (SW):-3.40 - 12"

INLET

GRATE: 2723.14

INV.OUT:-2.10 - 12"

BENCH MARK #6

N: 712632.83

E: 2507405.76

EL: 2724.56

BRASS CAP

BENCH MARK #5

N: 712713.54

E: 2507465.30

EL: 2724.86

BRASS CAP

N O

R

TH

V A H

O S

PI

TA

L

LO

O

P R O

A D

M

M

SEEPAGE BED FOR PRIMARY

CARE FACILITY PROJECT

(UNDER SEPARATE CONTRACT,

PROJECT NO. 531-325)

SEEPAGE BED FOR ADD

PARKING PROJECT

SIZE 35 FT. BY 115 FT.

APPROXIMATE LIMITS

OF WORK

1.83% 1.83%

1.

1.

2.00%

GROUNDWATER

OBSERVATION

WELL

CG421

CG420

CG421

STA 23+30.64, 124.82' LT

CB #5

8 LF 6" SD @ 2.00%

STORM DRAINAGE

PROFILE

CG410

STORM DRAINAGE

PROFILE

CG410

BC 2725.25

TC 2725.75

BC 2725.25

TC 2725.75

BC 2725.25

TC 2725.75

BC 2725.25

TC 2725.75

BC 2725.25

TC 2725.75

BC 2725.25

TC 2725.75

BC 2725.25

TC 2725.75

BC 2724.70

TC 2725.20

BC 2724.65

TC 2725.15

BC 2724.63

TC 2725.13

BC 2723.96

TC 2724.45

BC 2724.05

TC 2724.55

BC 2724.05

TC 2724.55

BC 2724.65

TC 2725.15

BC 2724.65

TC 2725.15

BC 2724.65

TC 2725.15

BC 2724.65

TC 2725.15

BC 2724.65

TC 2723.74

BC 2725.10

TC 2725.60

2725.25

2725.25

2725.25

BC 2724.65

TC 2725.15

BC 2725.37

TC 2725.87

SDMH

FOR PRIMARY CARE FACILITY

PROJECT

(UNDER SEPARATE CONTRACT,

PROJECT NO. 531-325)

LOWER RIM TO FINISH GRADE

RIM = 2725.20

CATCH BASIN

FOR PRIMARY CARE FACILITY

PROJECT

(UNDER SEPARATE CONTRACT,

PROJECT NO. 531-325)

CATCH BASIN

FOR PRIMARY CARE FACILITY PROJECT

(UNDER SEPARATE CONTRACT,

PROJECT NO. 531-325)

SEDIMENTATION TANK

FOR PRIMARY CARE FACILITY PROJECT

(UNDER SEPARATE CONTRACT,

PROJECT NO. 531-325)

APPROXIMATE LOCATION OF US

WEST DIRECT BURIED CABLE.

SEE NOTE 4.

STA 22+47.04

CB #3

CG421

BC 2724.28

TC 2724.78

BC 2723.24

TC 2725.15

STA. 22+44.34, 95.78' LT

1000-GALLON

SEDIMENTATION TANK

CG420

2.13%

BC 2724.72

TC 2725.22

BC 2723.57

TC 2724.08

BC 2724.31

TC 2724.81

CG421

CG420

CG421

PROPOSED TREE PER

LANDSCAPE (TYP)

STA 23+30.64, 124.82' LT

CB #5

STA. 22+47.02

CB #4

INLET CATCH BASIN TYPE II

RIM = 2724.07

6" IE = 2720.66 (OUT)

STA. 21+48.02

CB #1

CG420

CG421

STA. 21+48.02

CB #2

CG420

STREET LIGHT (TYP)

SEE ELECTRICAL PLANS

R

Call 811 two business days before you dig

CONSTRUCTION

DOCUMENTS

ADD PARKING ON PARADE

GROUNDS

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

JCG CM

Revisions: Date:

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

1 inch = 20 feet

10 20 40

CG400

GRADING & STORM DRAINAGE PLAN

1. CONTRACTOR SHALL FIELD VERIFY EXISTING LOCATION AND

INVERT ELEVATION OF STORM DRAIN POINT OF

CONNECTION AND NOTIFY ENGINEER IMMEDIATELY IF

DIFFERENT FROM PLANS.

2. ALL STORMWATER ELEMENTS INCLUDING PIPES, CATCH

BASINS, MANHOLES, AND WATER QUALITY FACILITIES WILL

BE MAINTAINED BY THE PROPERTY OWNER AFTER

COMPLETION OF THE PROJECT.

3. ALL DIMENSIONS, STATIONS, AND OFFSETS SHOWN FOR

UTILITY STRUCTURES ARE MEASURED TO THE CENTER OF

STRUCTURE, UNLESS NOTED OTHERWISE.

4. CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF THE

US WEST DIRECT BURIED CABLE AND PROTECT IT IN PLACE

DURING CONSTRUCTION. NOTIFY THE ENGINEER OF RECORD

IF THE FIELD LOCATION OF THE CABLE CONFLICTS WITH

PROPOSED IMPROVEMENTS.

5. REFER TO SHEET CG410 FOR STORM DRAINAGE PROFILES.

GRADING AND STORM DRAINAGE NOTES

LEGEND

APPROXIMATE LIMITS OF WORK

GRADE BREAK

SPOT ELEVATION

STORM DRAIN

STANDARD CONCRETE

CATCH MANHOLE

INLET CATCH BASIN

TYPE PER PLAN AND PROFILE

GROUNDWATER

OBSERVATION WELL

1000-GALLON

SEDIMENTATION TANK

SEEPAGE BED

XXXX

M

PROJECT

NORTH

C B

IN

LE

T

C A

TC

H B

A S

IN

T

YP

E

II

R

IM

.1

6"

I E

O U

T=

.6

(N

W

C B

IN

LE

T

C A

TC

H B

A S

IN

T

YP

E V

R

IM

.5

6"

I E

IN

.5

(S E)

6" I

E O

U T=

.5

(S W

C B

S

TA

N D

A R D

C O

N C R

ET

E C A

TC

H M

A N

H O

LE

R

IM

.4

6"

I E

IN

.3

(S W

6"

I E

IN

.5

(N E)

6" I

E

IN

.4

(S

E) 8"

I E

O U

T=

.5

(N

W

1, G

A

LL

O N

S

ED

IM

EN

TA

TI

O N

T A N

K R

IM

.1

IE

.9

(8

IN

S

IE

.2

(8

O U

T, E x x

S

EE

PA

G

E B

ED

IE

.9

(8

IN

W

CG

CG

8 LF 6" SD @ 2.00%

99 LF 6" SD @ 2.00% 26 LF 8" SD @ 2.00%

12 LF 8" SD @ 2.00%

STORM DRAIN PROFILE

1" = 10'

CG410

FINISH GRADE EXISTING

GRADE

CG

CG

CG

C B

S

TA

N D

A R D

C O

N C R

ET

E C A

TC

H M

A N

H O

LE

R

IM

.4

6"

I E

IN

.3

(S W

6"

I E

IN

.5

(N E)

6" I

E

IN

.4

(S

E) 8"

I E

O U

T=

.5

(N

W

C B

IN

LE

T

C A

TC

H B

A S

IN

T

YP

E V

R

IM

.8

6"

I E

O U

T=

.9

(N

E)

84 LF 6" SD @ 2.00%

EXISTING

GRADE

FINISH GRADE

STORM DRAIN PROFILE

1" = 10'

CG410

CG

CG

R

Call 811 two business days before you dig

CONSTRUCTION

DOCUMENTS

ADD PARKING ON PARADE

GROUNDS

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

JCG CM

Revisions: Date:

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

CG410

STORM DRAIN PROFILES

PLAN VIEW

SIDE VIEW SECTION

96" OD

O D

96"

4"181

4" 591 2"

90" ID

ID

27" 3"

20" 3"

37"

20"

SPACING

LARKEN

MFG NAME AND CAPACITY

MARKED ON LID

2' DIA CLEAR

ACCESS (2X)

WATERLINE

SAND

TRAP

INLETOUTLET

20"

3"

27"

60"

FLOW

90" ID

1 2"

6"

3"

" 30

8"

3"

1 2" OUTLET

INVERT

SHOULD BE

BELOW

PARTITION

INVERT

INLET INVERT SHOULD

BE 0.1' ABOVE OUTLET

PARTITION INVERT

PROFILE VIEW

4.

0'

TANK RIM=2724.13 TANK RIM=2724.13

8" IE IN=2717.99

TANK LID=2720.39

INSTALL 8"

PERFORATED PE

TANK IE=2714.72

TANK IE OUT=2717.22

TOP OF BAFFLE = 2717.89

BOTTOM OF

BED = 2714.15

BOTTOM OF

SAND = 2712.65

ASTM C-33 SAND

2" WASHED DRAIN ROCK

1.

5'

12' NON-PERFORATED

8" PE

EXCAVATION FOR SEEPAGE PIT MUST

EXTEND AT LEAST ONE FOOT INTO

FREE DRAINING ACTIVE MATERIALS

PIPE IE IN=2716.98

INSTALL 4 OZ / SY FILTER

FABRIC ON TOP OF AND

AROUND SIDES OF DRAIN ROCK

1,000 GALLON SEDIMENTATION TANK

NTS

CG420

TOP OF SEEPAGE BED=2718.15

8" OUTLET

35'

4' 1.

5'

5' M

IN

6"

MAINTAIN 6" OF DRAIN ROCK

OVER TOP OF PERF ADS

8-INCH PE

PERFORATED PIPE

DRAINAGE PIT IS WASHED 2"

DRAIN ROCK. WRAP ENTIRE

PIT EXCEPT BOTTOM IN

MINIMUM 4 0Z/SQ YD

NON-WOVEN FILTER FABRIC

ASTM C-33 SAND

WATER TABLE

ELEVATION

SEEPAGE PIT

SCALE 1" = 40'

CG420

VEHICULAR

ASPHALT PAVEMENT

GUTTER

(WHERE OCCURS)

PARKING LOT

CATCH BASIN

TYPE PER PLAN AND PROFILE

POUR CURB AROUND

CATCH BASIN STRUCTURE

LOCATE BACK OF FRAME

0.5" FROM FACE OF CURB

CURB

CATCH BASIN SETTING AT CURB

SCALE 1" = 40'

CG420

5.

1'

CP510

R

Call 811 two business days before you dig

CONSTRUCTION

DOCUMENTS

ADD PARKING ON PARADE

GROUNDS

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

JCG CM

Revisions: Date:

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

CG420

STORM DRAINAGE DETAILS

INLET CATCH BASIN TYPE II

NTS

CG421

INLET CATCH BASIN TYPE V

NTS

CG421

STANDARD CONCRETE CATCH MANHOLE

NTS

CG421

GROUND WATER OBSERVATION WELL

NTS

CG421

NOTES:

1. A 24-INCH CONCRETE COLLAR (FOR TRAFFIC AREAS) IS

REQUIRED FOR THE GROUNDWATER OBSERVATION WELL.

INLET CATCH BASIN TYPE III

NTS

CG421

CATCH BASIN GRATE TYPE I

NTS

CG421

CATCH BASIN GRATE TYPE II

NTS

CG421

R

Call 811 two business days before you dig

CONSTRUCTION

DOCUMENTS

ADD PARKING ON PARADE

GROUNDS

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

JCG CM

Revisions: Date:

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

CG421

STORM DRAINAGE DETAILS

CATCH BASIN GRATE TYPE III

NTS

CG422

STANDARD MANHOLE FRAME, COVER AND RISER

NTS

CG422

R

Call 811 two business days before you dig

CONSTRUCTION

DOCUMENTS

ADD PARKING ON PARADE

GROUNDS

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

JCG CM

Revisions: Date:

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

CG422

STORM DRAINAGE DETAILS

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SEWER MANHOLE

INV. IN

(S

E):-7 .17 - 8

INV. IN

(N

E):-7 .19 - 8

INV.OUT (N

W):-7

.20 - 8

G R

AS

S

AR

EA

G R

AS

S

AR

EA

AS

PH

AL

T

ASPHALT

BM-#6

BM-#5

S&G TRAP

RIM (NE): 2724.41

INV.IN(NW) -3.75 - 12"

RIM (SW): 2724.36

INV.OUT (NW):-4.05 - 12"

INLET

GRATE: 2723.28

INV.IN:-2.10 - 12"

INV.OUT:-2.40 - 12"

INLET

GRATE: 2723.15

INV.IN & OUT:-2.00

STORM DRAIN MANHOLE

RIM: 2723.50

INV. IN (NE&SE):-3.55

INV.OUT (SW):-3.55

S&G TRAP

RIM (NE): 2723.91

INV.IN(NW) -3.10 - 12"

RIM (SW): 2723.91

INV.OUT (NW):-3.65 - 12"

INLET

GRATE: 2723.01

INV.IN:-1.80 - 12"

INV.OUT:-2.00 - 12"

INLET

GRATE: 2722.97

INV.IN & OUT:-1.90 - 12"

STORM DRAIN MANHOLE

RIM: 2723.22

INV. IN (NE&SE):-3.40 - 12"

INV.OUT (SW):-3.40 - 12"

INLET

GRATE: 2723.14

INV.OUT:-2.10 - 12"

BENCH MARK #6

N: 712632.83

E: 2507405.76

EL: 2724.56

BRASS CAP

BENCH MARK #5

N: 712713.54

E: 2507465.30

EL: 2724.86

BRASS CAP

VEHICULAR ASPHALT

PAVEMENT

CONCRETE VERTICAL CURB

N O

R

TH

V A H

O S

PI

TA

L

LO

O

P R O

A D

S

TA

LL

S

'X

10 STALLS @ 9'X18'

S

TA

LL

S

'X

S

TA

LL

S

'X

24.0'

24.0' 24.0'

24.0'

5.0'

APPROXIMATE LIMITS

OF WORK

C O

N S

TR

U C

TI

O N

B A S E

LI

N

E

24' WIDE DRIVEWAY

CP510

CP510

VERTICAL CURB

AND GUTTER

13.8'

4.4'

9.

0'

.0

CP510

APPROXIMATE LOCATION OF US

WEST DIRECT BURIED CABLE.

SEE NOTE 5.

STA 23+41.52, 191.84' LT

STA 23+62.62, 83.84' LT

STA 23+05.52, 65.84' LT

STA 23+30.67, 36.94' LT

STA 20+95.30, 192.34' LT

STA 23+12.07, 149.84' LT

S

TA

LL

S

'X

STA 23+12.07, 107.84' LT

C1

C2

8 FT WIDE

PEDESTRIAN CROSSWALK

CP510

N O

R

TH

V A H

O S

PI

TA

L

LO

O

P R O

A D

STA 20+62.52, 65.84' LT

13.1'

CP510 CP510

STA 23+15.15, 56.69' LT

"STOP" SIGN

Curve Table

Curve #

C1

C2

Length

31.50'

31.40'

Radius

20.09'

20.06'

Delta

89.83°

89.68°

PC STATION/OFFSET 1/2 PC STATION/OFFSET PT STATION/OFFSET

STA 23+62.69, 36.97' LT STA 23+42.62, 57.03' LT

STA 23+18.62, 56.94' LTSTA 22+98.64, 36.90' LT STA 23+17.10, 49.29' LT

STA 23+48.51, 42.85' LT

R

Call 811 two business days before you dig

CONSTRUCTION

DOCUMENTS

ADD PARKING ON PARADE

GROUNDS

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

JCG CM

Revisions: Date:

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

1. SEE DETAIL 3 ON SHEET CP510 FOR INFORMATION

REGARDING PAINT STRIPING FOR THE VA PARKING LOT

LAYOUT.

2. SEE LANDSCAPE PLANS FOR SITE FURNISHINGS.

3. ALL STATIONS, OFFSETS, AND DIMENSIONS ARE MEASURED

TO FACE OF CURB, OR EDGE OF PAVEMENT UNLESS

OTHERWISE NOTED.

4. ALL CURB RADII ARE 3.0 FT UNLESS NOTED OTHERWISE.

5. CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF THE

US WEST DIRECT BURIED CABLE AND PROTECT IT IN PLACE

DURING CONSTRUCTION. NOTIFY THE ENGINEER OF RECORD

IF THE FIELD LOCATION OF THE CABLE CONFLICTS WITH

PROPOSED IMPROVEMENTS. ALSO SEE SITE ELECTRICAL

PLAN ES100.

PAVING AND HORIZONTAL CONTROL NOTES

LEGEND

APPROXIMATE LIMITS OF WORK

CONCRETE VERTICAL CURB

VERTICAL CURB AND GUTTER

VEHICULAR ASPHALT

PAVEMENT

CP500

PAVING & HORIZONTAL CONTROL

PLAN

1 inch = 20 feet

10 20 40

PROJECT

NORTH

3"

4"

6"

ASPHALTIC CONCRETE

CRUSHED AGGREGATE

BASE

STRUCTURAL SUBBASECOMPACTED SUBGRADE

VEHICULAR ASPHALT PAVEMENT

SCALE: 1" = 1'

CP510

CONCRETE VERTICAL CURB

NOT TO SCALE

CP510

2" R.

NOTES:

1. ALL CONCRETE CURBS AND TRANSITIONS, SHALL HAVE A

MINIMUM COMPRESSIVE STRENGTH OF 2,500 PSI.

2. MAXIMUM SPACING ON SCORED JOINTS SHALL BE 15'.

3. 1/2" THICK EXPANSION JOINTS SHALL BE LOCATED AT

TANGENT POINTS IN CURB RETURNS, TRANSITIONS, AND

AT A MAXIMUM OF 60' INTERVALS. EXPANSION MATERIAL

SHALL ALSO BE PLACED BETWEEN CURBS AND ADJACENT

STRUCTURES, SIDEWALKS, DRIVEWAYS AND CURB ACCESS

RAMPS. THE 1/2" JOINT FILLER SHALL EXTEND THE FULL

DEPTH OF THE CONCRETE.

4. CONCRETE SHALL BE FINISHED WITH A STEEL TROWEL

FOLLOWED BY BRUSHING WITH A FINE BRUSH ALONG THE

LENGTH OF THE CURB OR CURB AND GUTTER.

5. SINGLE CURB MAY BE CONSTRUCTED BY THE USE OF

FORMS OR MAY BE SLIP FORMED.

6. ALL EXPOSED EDGES AND HAND TOOLED JOINTS SHALL BE

FINISHED WITH A TOOL HAVING A 1/4" RADIUS UNLESS A

LARGER RADIUS IS INDICATED BY THE APPLICABLE

STANDARD DETAIL OR PROJECT PLANS.

7. FOR REVEALS OF 6" TO LESS THAN 8".

ROADWAY &

PAVEMENT

WIDTH

CONCRETE VERTICAL CURB

NOTE 7

9 1/2"

10"

N O

TE

6"

6"

1:4 CURB

BATTER

PARKING STALL LAYOUT

NOT TO SCALE

CP510

6" VERTICAL CURB AND GUTTER

NOT TO SCALE

CP510

4" PAINTED PARKING STALL

LINES, YELLOW (TYP)

9.0' 9.0' 9.0' 9.0'

.0

8.0'

5.5'

1.0'

1.0'

1'X8' THERMOPLASTIC

STRIPES, WHITE (TYP)

8' PEDESTRIAN CROSSWALK STRIPING

SCALE: 1" = 2'

CP510

STOP SIGN

NOT TO SCALE

CP510

R

Call 811 two business days before you dig

CONSTRUCTION

DOCUMENTS

ADD PARKING ON PARADE

GROUNDS

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

JCG CM

Revisions: Date:

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

CP510

PAVING DETAILS

SIGN INSTALLATION

NOT TO SCALE

CP510

Plant Legend:

ID Qty Botanical Name Common Name Scheduled Size Remarks ACH-M 16 Achillea millefolium Yarrow 4" Pot Perenial, Drought Tolerant, Native, Salt tolerant Aromatic herb ARCU 722 Arctostaphylos uva-ursi Kinnikinick 1 Gallon Evergreen, Ground Cover, Drought Tolerant, Native, White and pink flower, year round interest BETU-N 9 Betula nigra River Birch 2" Caliper Deciduous, narrow vertical tree, peeling bark CARB 12 Carpinus betulus European Hornbeam 2" Caliper Deciduous, small specimen tree CHOT-S 5 Choisya ternata 'Sundance' Golden Mexican Orange 5 Gallon Evergreen, Drought Tolerant, low shrub, golden foliage CORA 2 Corylus colurna Turkish Filburt 2" Caliper Deciduous, Drought Tolerant, Street tree CORM 7 Cornus mas Cornelian Cherry 1.5" Caliper Deciduous, small tree, yellow flower in spring, edible LAVA-H 26 Lavandula stoechas 'Silver Anouk' Silver Anouk Spanish Lavender 1 Gallon Semi-Evergreen, Drought Tolerant, fragrant purple flowers MAGS-A 3 Magnolia x soulangiana 'Alexandrina' Alexander Magnolia 2" Caliper Deciduous, Deer Rresistant, medium tree, pink saucer shape flowers MAH-R 232 Mahonia repens Creeping Oregon Grape 1 Gallon Evergreen, Drought Tolerant, Native, Deer Rresistant, low shrub, yellow fragrant flower, berries MISS 15 Miscanthus sinensis Chinese Silver Grass 1 Gallon Perennial, Drought Tolerant, dupright grass, copper to silver foliage PINC-C 4 Picea omorika Spruce, Serbian 6' Height Evergreen, Native, Drought Tolerant, Deer Resistant, native conifer PINM 39 Pinus mugo 'Mops' Mops Mugo Pine 2 Gallon Evergreen, Drought Tolerant, low shrub, dwarf conifer QUER 2 Quercus robur English Oak 2" Caliper Deciduous, Drought Tolerant, street tree, fall color ROSG 26 Rosa gymnocarpa Bald Hip Rose 1 Gallon Deciduous, Native, Deer Resistant, medium shrub, pink flowers in summer SPIB-G 61 Spiraea x bumalda 'Goldflame' Goldflame Spirea 1 Gallon Deciduous, Drought Tolerant, low golden shrub, spring flowers, fall color SYMA 37 Symphoricarpos albus Snowberry 1 Gallon Deciduous, Native, Drought Tolerant, upright shrub, white berries TSUG-H 3 Tsuga canadensis Canadian Hemlock 6' Height Evergreen, Native, Drought Tolerant, Deer Resistant, native conifer

STATE OF

WASHINGTON

REGISTERED

LANDSCAPE ARCHITECT

CERTIFICATE NO.1272

Emily Russell

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING

DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING

DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

LS101

LANDSCAPE PLAN

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

ADD PARKING ON PARADE

GROUNDS

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

ELR ELR/KDC

Revisions: Date:

CONSTRUCTION

DOCUMENTS

245 4th Street #501 Bremerton WA 98337

Landscape Architecture & Urban Design Emily Russell, PLA, ASLA

360-990-1720 www.russelldesignsource.com emily@russelldesignsource.com

S U

R V

E Y P

O

IN

T

S U

R V

E Y

P O

IN

T

C B1

C B1

M

C B

C B

C B

C B

M

SPIB-G

MAH-R

CARB

CORM

MAGS-A

CORA

BETU-N

PINC-C

PINC-C

TSUG-H

QUERMAGS-A

ARCU

ROSG

SYMA

PINM

MISS

LAVA-H

ACH-M

4'-0"

8'-0"

PINM

8' -0

CHOT-S

CORA EXISTING LAWN TO REMAIN

EXISTING ESTABLISHED

TREES TO REMAIN. TYP.

NOTE: REPAIR ANY DAMAGE TO

SOD CAUSED BY CONSTRUCTION

DRAIN

FIELD

BUILDING 127

LIMIT OF WORK

DRAIN

FIELD

24'-0"

SOD 4' WIDE

GROUND

COVER BED TO

ACCOMMODATE

VEHICLE

OVERHANG,

TYP.

PROPOSED TREES TO

BE PLANTED OUTSIDE

OF 4' CLEAR ZONE

BEHIND PARKING LOT

CURB

4' WIDE

GROUND

COVER BED TO

ACCOMMODATE

VEHICLE

OVERHANG,

TYP.

NOTE: REPAIR ANY DAMAGE TO

SOD CAUSED BY CONSTRUCTION

3" BARK MULCH IN

PLANTING BEDS

NOTE: VERIFY IRRIGATION LINE

LOCATION PRIOR TO PLANTING

TREES IN SOD AREA TO AVOID

DAMAGE TO THE EXISTING

IRRIGATION SYSTEM.

1" = 30'-0"1 PARKING LOT LANDSCAPE PLAN

NOTE: ALL PLANT LABELS ON LANDSCAPE PLAN ARE TYPICAL

cjaim Snapshot

STATE OF

WASHINGTON

REGISTERED

LANDSCAPE ARCHITECT

CERTIFICATE NO.1272

Emily Russell

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING

DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING

DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

LS102

LANDSCAPE DETAILS

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

ADD PARKING ON PARADE

GROUNDS

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

ELR ELR/KDC

Revisions: Date:

CONSTRUCTION

DOCUMENTS

245 4th Street #501 Bremerton WA 98337

Landscape Architecture & Urban Design Emily Russell, PLA, ASLA

360-990-1720 www.russelldesignsource.com emily@russelldesignsource.com

RUBBER HOSE AT BARK

GUY WIRES (3), WHITE FLAG ON EACH TO

INCREASE VISIBILITY. AVOID TIGHT GUY

WIRES AS THEY PREVENT NATURAL SWAY

TURNBUCKLE (3), GALVANIZED OR DIP-PAINTED

SET TREE AT ORIGINAL GRADE

ORGANIC COMPOST

SOIL SAUCER: USE PREPARED TOPSOIL 150MM (6") MIN.

WOOD STAKES (3)

ROPES AT TOP OF BALL SHALL BE CUT. REMOVE TOP

1/3 OF BURLAP. NON- BIODEGRADABLE MATERIAL

SHALL BE TOTALLY REMOVED

PREPARED ADMIXTURE BACKFILL OR NATIVE SOIL

TAMPED ADMIXTURE BACKFILL

2X BALL DIA. MIN.

CROWN OF ROOT BALL SHALL BEAR SAME

RELATION (OR SLIGHTLY ABOVE) TO FINISHED

GRADE AS IT BORE TO PREVIOUS GRADE.

ORGANIC COMPOST 75MM (3") MIN.

CREATE SOIL SAUCER WITH TOPSOIL 150MM (6") MIN.

FOLD DOWN OR CUT AND REMOVE TOP 1/3 OF BURLAP IF

NON- BIODEGRADABLE WRAP IS USED. REMOVE TOTALLY.

PREPARED SOIL BACKFILL

PREPARED ADMIXTURE

BACKFILL OR NATIVE SOIL

2X BALL DIA. MIN.

SET TREE AT ORIGINAL GRADE

ORGANIC COMPOST 75MM (3") MIN.

SOIL SAUCER: USE PREPARED TOPSOIL 150MM (6") MIN.

ROPES AT TOP OF BALL SHALL BE CUT. REMOVE 1/3 OF

BURLAP. NON-BIODEGRADABLE MATERIAL SHALL BE

TOTALLY REMOVED

PREPARED ADMIXTURE BACKFILL

PREPARED SUBGRADE PEDESTAL

2X BALL DIA. MIN.

CREATE SAUCER WITH TOPSOIL 150MM (6") MIN.

ORGANIC COMPOST 75MM (3") MIN.

ROPES AT TOP OF BALL SHALL BE CUT. REMOVE

TOP 1/3 OF BURLAP. NON-BIODEGRADABLE

MATERIAL SHALL BE TOTALLY REMOVED.

GENTLY COMPACTED TOPSOIL MIXTURE

TAMPED ADMIXTURE BACKFILL

2X BALL DIA. MIN.

2'-4" LAYER OF ORGANIC COMPOST. DO

NOT BURRY STEMS OR TRUNK

EXISTING GRADE

BACKFILL WITH TOPSOIL FROM

HOLE AND WATER THOROUGHLY.

PLANT TOP OF ROOT BALL 1"-2"

ABOVE SURROUNDING GRADE.

ROOTS AT OUTER EDGE OF ROOT BALL

SHOULD BE LOOSENED TO ENSURE

GOOD BACKFILL-TO-ROOT CONTACT

ROOT BALL SHOULD SIT DIRECTLY ON

TOP OF UNDISTURBED SOIL

HOLE SHOULD BE THREE TIMES AS WIDE AS

ROOT BALL WITH SLOPED SIDES

ORGANIC COMPOST

FINISHED GRADE.

REMOVE CONTAINER AND

LIGHTLY SCARIFY ROOT

MASS.

PREPARED SOIL MIXTURE.

NOTE: SHRUB TO BEAR SAME RELATION TO FINISHED GRADE AFTER

SETTLEMENT AS IT BORE TO PREVIOUS GRADE.

NTS1 TREE PLANTING AND STAKING

NTS2 CONIFEROUS TREE PLANTING

NTS6 CONTAINER SHRUB PLANTING

NTS5 B&B SHRUB PLANTING

NTS3 MULTI TRUNK TREE PLANTING

NTS4 GROUND COVER PLANTING DETAIL

REGISTERED

LANDSCAPE ARCHITECT

CERTIFICATE NO.1272

Emily Russell

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING

DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING

DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

LI101

IRRIGATION DEMO PLAN

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

ADD PARKING ON PARADE

GROUNDS

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

ELR ELR/KDC

Revisions: Date:

CONSTRUCTION

DOCUMENTS

245 4th Street #501 Bremerton WA 98337

Landscape Architecture & Urban Design Emily Russell, PLA, ASLA

360-990-1720 www.russelldesignsource.com emily@russelldesignsource.com

1" = 30'-0"1 IRRIGATION DEMO PLAN

11/2

11/2

3 3

C W/R

M .S

I V

I V

I V

I V

M

S U

R V

E Y P

O

IN

T

S U

R V

E Y

P O

IN

T

CAP EXISTING IRRIGATION LINE, VALVE TO REMAIN

IRRIGATION HEADS IN THIS AREA

SHOULD REMAIN FOR LATER USE.

CAP ALL DISCONNECTED LINES

DURING CONSTRUCTION.

IRRIGATION DEMO AREA. ALL

IRRIGATION IN THIS AREA

WILL BE DISRUPTED BY

CONSTRUCTION. THE

IRRIGATION SHALL BE

DEMOLISHED AND REMOVED

FROM SITE

SEE PRIMARY CARE CONSTRUCTION

SET FOR IRRIGATION DEMO PLAN

IRRIGATION IN THIS AREA SHOULD

REMAIN UNDISTURBED AND PROTECTED

CAP EXISTING IRRIGATION LINE, VALVE TO REMAIN

EX

IS

TI

NG

M

AI

N

LI

NE

IRRIGATION DEMO AREA

CAP 5 EXISTING IRRIGATION

LINES IN THIS AREA FOR

PROTECTION DURING

CONSTRUCTION. FIELD

VERIFY LOCATIONS WITH

AREAS OF DISTURBANCE.

REMOVE VALVE

REMOVE VALVE

REMOVE VALVE

CAP EXISTING IRRIGATION LINE, VALVE TO REMAIN

cjaim Snapshot

REGISTERED

LANDSCAPE ARCHITECT

CERTIFICATE NO.1272

Emily Russell

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING

DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING

DISCIPLINE:

Approved:

Approved:CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

LI102

DIAGRAMMATIC IRRIGATION

PLANSPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

ADD PARKING ON PARADE

GROUNDS

BOISE VA MEDICAL CENTER, BOISE ID

531-22-103

SITE

ELR ELR/KDC

Revisions: Date:

CONSTRUCTION

DOCUMENTS

245 4th Street #501 Bremerton WA 98337

Landscape Architecture & Urban Design Emily Russell, PLA, ASLA

360-990-1720 www.russelldesignsource.com emily@russelldesignsource.com

1" = 30'-0"1 DIAGRAMMATIC PARKING LOT IRRIGATION PLAN

IRRIGATION NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

THE IRRIGATION PLAN PROVIDED IS DIAGRAMATIC/SCHEMATIC IN NATURE. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL IRRIGATION COMPONENTS, VALVES, ROTOR AND DRIPLINE LAYOUT, PREASURE REQUIREMENTS, ZONES, ETC PRIOR TO CONSTRUCTION.

SYSTEM SHALL BE COVERED UNDER A ONE YEAR WARRANTY.

CONNECTION TO WATER LINE SHALL BE THE CONTRACTOR'S RESPONSIBILITY. CONNECT TO EXISTING SYSTEM.

ALL WORK WILL CONFORM TO CODES AND REGULATIONS ISSUED BY ANY GOVERNING AUTHORITIES. OBTAIN ALL

PERMITS, LICENSES, ETC. REQUIRED FOR EXECUTION OF WORK.

LAYOUT IRRIGATION HEADS FOR EACH STATION PRIOR TO PLACEMENT TO INSURE INDIVIDUAL PLANTING AREA

COVERAGE.

PROVIDE HEAD TO HEAD COVERAGE FOR ALL PLANTINGS AREAS

LAY MAIN PIPE RUN TO A DEPTH OF 18" MINIMUM FROM FINISH GRADE AND LATERALS TO A DEPTH OF 12" MINIMUM.

ALL IRRIGATION HEADS IN SHRUB BEDS TO BE 4" POP-UPS.

VERIFY REQUIRED PRESSURE PRIOR TO CONSTRUCTION. INCLUDE PRESSURE COMPENSATING HEADS, VALVES

AND/OR REGULATOR AS NECESSARY.

PROVIDE ALL LABOR, MATERIALS, APPLIANCES, EQUIPMENT, SERVICES AND INCIDENTALS NECESSARY FOR FURNISHING, INSTALLING AND TESTING, COMPLETE AND READY FOR OPERATION, IN A MANNER SATISFACTORY TO THE

OWNER.

DUE TO MODIFICATIONS MADE DURING CONSTRUCTION, SITE CONDITIONS MAY VARY FROM THOSE SHOWN. VERIFY ALL SUCH CONDITIONS AS WELL AS THE PRESENCE AND LOCATION OF ALL UTILITIES PRIOR TO CONSTRUCTION. NO CHANGE IN CONTRACT PRICE WILL BE GRANTED FOR FAILURE TO OBSERVE THIS REQUIREMENT.

CLEAN-UP AND DISPOSE OF OFF OWNER'S PROPERTY ALL DEBRIS, WASTE AND EXCESS CONSTRUCTION MATERIALS

FOLLOWING COMPLETION AND LEAVE NEAT, CLEAN READY FOR OWNER'S USE.

THE CONTRACTOR IS RESPONSIBLE FOR THE POWER SUPPLY REQUIREMENTS.

ALL VALVES, PIPE, HEADS, ETC NOT SHOWN BUT REQUIRED FOR CONSTRUCTION ARE THE CONTRACTORS

RESPONSIBILTY.

COORDINATE THE LOCATION OF THE CONTROLLER WITH THE LOCATION OF THE EXISTING SYSTEMS CONTROLLERS EXISTING SYSTEM SHOULD HAVE AN EXISITNG BACKFLOW PREVENTER. IF REQUIRED FOR NEW ADDITION. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE APPROPRIATE COMPONENT FOR THE NEW SYSTEM ADDITION.

Legend:

EXISTING BASELINE 3200 TWO-WIRE CONTROLLER

14 GAUGE WIRE

HUNTER ICZ-101 CONTROL KIT FOR DRIP

HUNTER HEAD I20-4 w/CV BLUE #3 NOZZLE (3), I20-4 w/CV BLUE #6 NOZZLE (6), AND I20-4-MPR-25-Q RED NOZZLE (Q), I20-4-MPR-25-H RED NOZZLE (H)

MAINLINE PIPE: 1 1/2" SIZE IF NOT NOTED. CLASS 200 PVC SOLVENT WELD PIPE UTILIZING SCH

40 PVC SOLVENT WELD FITTINGS.

LATERAL LINE PIPE: CLASS 200 PVC SOLVENT WELD PIPE UTILIZING SCH 40 PVC SOLVENT

WELD FITTINGS.

1.00 in1.00 in

HUNTER INDUSTRIES DRIPLINE. REFER TO HUNTER INDUSTRIES_DRIPLINE_CHARTS FOR

APPROPRIATE LINE .4 GPH WITH 18" EMITTERS SPACING

LATERAL PIPING 1"

LATERAL PIPING 1.25"

LATERAL PIPING 1.5"

LATERAL PIPING 2"

EXISTING HUNTER ICV VALVE

BASELINE SUBSTATION

EXISTING WIND AND RAIN SENSOR

EXISTING SOIL MOISTURE SENSOR

BASELINE MASTER VALVE AND FLOW SENSOR

11/2

11/2

3 3

C W/R

M .S

I V

I V

I V

I V

M

S U

R V

E Y P

O

IN

T

S U

R V

E Y

P O

IN

T

C B1

C B1

M

C B

C B

C B

C B

M

Existing Irrigated Area

3" E

XI

ST

IN

G M

AI

N

LI

NE

BUILDING 127

EXISTING HUNTER ICV VALVE. DECODER #18

NEW HUNTER ICZ-101 CONTROL KIT FOR DRIP. USE DECODER #16

EXISTING HUNTER ICV VALVE. DECODER #13

66 6 6

QQ

H H

H H

H H

H H

H H

H H

H H

H H

H H

Q Q

-EXISTING BASELINE 3200 CONTROLLER.

ALL NEW AND REUSED IRRIGATION

EQUIPMENT TO BE WIRED BACK TO THAT

BASELINE 3200 CONTROLLER.

CONNECT TO EXISTING

IRRIGATION HEAD

EXISTING HUNTER ICV VALVE DECODER #17

NEW HUNTER ICZ-101 CONTROL KIT FOR DRIP. USE DECODER #15

NEW HUNTER ICZ-101 CONTROL KIT FOR DRIP. NEW DECODER REQUIRED

FOR VALVE IF ONE DOES NOT ALREADY…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .