Attachment_2b_-_Technical_Questionnaire__3CY_.xlsx
XLSX spreadsheet 40 KB Posted
- Solicitation number
- 0000039133
- Issued by
- Sacramento County, San Francisco City, California
About this file
This is a Technical Questionnaire for the State of California's Department of General Services - Procurement Division regarding a Sander Body With Anti-Ice, Directional, Roll-Off equipment specification (BDYROFDSBTK33-430-261T for 3-cubic-yard models). Bidders are required to complete the questionnaire for each Contract Line Item Number (CLIN), providing detailed specifications for the equipment being bid. The questionnaire covers comprehensive technical requirements across 17 specification items, including body interior and exterior dimensions, floor/auger conveyor specifications, sidewalls, liquid reservoir details, spinner chute assembly, anti-ice and pre-wetting systems, electrical components, weight balance calculations, and paint specifications. Responses must be submitted in writing to the Procurement Official, Tayron Jackson, as electronic bid submissions are not permitted. A bidder conference will be held for this solicitation, with details provided in the attached solicitation documentation.
Bidders must complete all highlighted cells in the Technical Questionnaire, with blank responses potentially resulting in bid rejection. The questionnaire requires specific technical data such as hopper opening dimensions, granular capacity in cubic yards, stainless steel gauges for various components, sensor specifications measured in pulses per revolution or pulses per gallon, weight calculations including center of gravity measurements, and paint brand, color, and lead content information. This technical questionnaire takes precedence over any accompanying manufacturer literature, establishing it as the controlling document for bid evaluation and ensuring consistent technical compliance across all submitted proposals.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| APP_Cover_Page.docx | DOCX document | |
| Attachment_4_-_Schematic_Drawing__3CY_.pdf | ||
| IFB_Event_ID_0000039133.docx | DOCX document | |
| Attachment_1_-_Pricing_Workbook.xlsx | XLSX spreadsheet | |
| Attachment_3_-_Narrative_Response.xlsx | XLSX spreadsheet | |
| Attachment_4a_-_Schematic_Drawing__6CY_.pdf | ||
| Attachment_2a_-_Bid_Spec_BDYROFDSBTK33-430-261T__3CY_.pdf | ||
| Attachment_2d_-_Technical_Questionnaire__6CY_.xlsx | XLSX spreadsheet | |
| Attachment_2c_-_Bid_Spec_BDYROFDSBTK53-430-261T__6CY_.pdf | ||
| Attachment_2_-_Admin_Bid_Spec__3CY_and_6CY_.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Technical Questionnaire
Specification Section Reference corresponds to technical specification Attachment 2a - Bid Spec BDYROFDSBTK33-430-261T (3CY). For each Contract Line Item Number (CLIN), submit a respective Technical Questionnaire. Responses left blank may be considered non-responsive and show cause for rejection of the bid. If a requirement is not applicable to the CLIN, N/A may be a response. This technical questionnaire shall take precedence over accompanying literature. COMPLETE THE FOLLOWING HIGHLIGHTED CELLS.
| Item | Specification Section Reference | Requirement | Response |
| 1 | N/A | Bidder Name | |
| 2 | N/A | CLIN | |
| 3 | N/A | Manufacturer (OEM) | |
| 4 | N/A | Model | |
| 5 | N/A | Style | |
| 6 | 2.a.i.1 | Body Interior Dimensions |
1. Hopper opening length 7 2.a.i.2 Body Interior Dimensions
1. Granular capacity
2. Sidewall length
3. Sidewall height
4. Width (tapered)
i. Top
ii. Bottom 8 2.a.ii.1 Body Exterior Dimensions
1. Width 9 2.c Floor/Auger Conveyor
1. Auger trough stainless steel gauge
2. Auger system
i. Number of augers
ii. Auger diameter
3. Auger pulse sensor pulses/per revolution 10 2.d Sidewalls
1. Sidewalls stainless steel gauge 11 2.i Liquid Reservoir
1. Reservoir stainless steel gauge or heavy-duty low-density polyethylene
2. Tie down stainless steel band thickness
3. Reservoir capacity 12 3 Spinner Chute Assembly
1. Number of spinner position telescopic adjustments
2. Sensor feedback response pulses per revolution 13 4 Anti-ice System
1. Anti-ice flow meter pulses per gallon 14 5 Pre-wetting System
1. Pre-wet flow meter pulses per gallon 15 8.a Electrical
1. Pigtail length 16 11 Weight Balance
1. Body empty weight (pounds with roll-off frame)
2. Granular capacity (cubic yards @ 3,000 pounds per yard)
3. Liquid capacity (gallons @ 10 pounds per gallon)
4. Center of gravity at full capacity (inches from bumper stop)
5. Vertical center of gravity at full capacity (inches (height))
6. Length from rear of bumper stop to front of body (inches) 17 17 Paint
1. Brand
2. Color
3. Lead content End of Sheet