attachment_2_RFB DNCR CAP-2403.pdf

PDF 375 KB Posted

Attached to
Metal Roofing Replacement Pole Barn (NHQ02) North Country Resources Center Lancaster, NH
Solicitation number
RFB DNCR CAP-2403
Issued by
Coos County, New Hampshire

About this file

This document appears to be a Request for Bids (RFB) from the State of New Hampshire Department of Natural and Cultural Resources for a metal roof replacement project on two pole barns located at the North Country Resources Center in Lancaster, New Hampshire. The project involves stripping and removing existing roofing materials, inspecting and repairing wood purlins, installing RTD sheathing, a hi-temp metal roof underlayment, light transmitting panels, and a new metal roof. The work is to be completed by July 11, 2023. The document includes detailed drawings and specifications for the roofing materials and installation methods.

The RFB does not provide information on pricing terms, set asides, incumbent contractors, funding sources, or other salient commercial details. The focus of the document is on the technical requirements and scope of work for the metal roof replacement project.

View the file

Other files

File Type Posted
RFB DNCR CAP-2403.pdf PDF
attachment_1_RFB DNCR CAP-2403.pdf PDF
RFB DNCR CAP-2403_respondents.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

AutoCAD SHX Text

STATE OF NEW HAMPSHIRE

AutoCAD SHX Text

DEPARTMENT OF NATURAL AND CULTURAL RESOURCES

AutoCAD SHX Text

METAL ROOF ROOF REPLACEMENT

AutoCAD SHX Text

POLE BARNS NHQ02 & NHQ03

AutoCAD SHX Text

DESIGN DEVELOPMENT & MAINTENANCE SECTION

AutoCAD SHX Text

OF

AutoCAD SHX Text

AutoCAD SHX Text

LANCASTER, NEW HAMPSHIRE

AutoCAD SHX Text

NORTH COUNTRY RESOURCES CENTER

AutoCAD SHX Text

ED MUSSEY

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

JUL 11, 2023

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text

CAP-2218

AutoCAD SHX Text NOTES: 1. STRIP AND REMOVE ALL STRIP AND REMOVE ALL ROOFING MATERIALS. 2. INSPECT AND REPAIR WOOD PURLINS. 3. INSTALL RTD SHEATHING 2332 RTD SHEATHING IN AREAS INDICATED. 4. INSTALL HI-TEMP METAL ROOF UNDERLAYMENT OVER SHEATHING. 5. INSTALL LIGHT TRANSMITTING PANELS IN AREAS INDICATED. 6. INSPECT & REPAIR CHIMNEY IF NECESSARY. 7. INSTALL NEW METAL ROOF PANELS.

AutoCAD SHX Text

PBR PANEL FASTNER SPACING OVER WOOD DECK (TYPICAL)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

EAVE MEMBER

AutoCAD SHX Text 1/4-14 x 7/8" LONG-LIFE LAPTEK

AutoCAD SHX Text

W/WASHER @ 12" O.C.

AutoCAD SHX Text 1/4-14 x 1 LONG-LIFE

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

'TYPE AB' SELF-TAPPER

AutoCAD SHX Text

(6) PER PANEL

AutoCAD SHX Text 1/4-14 x 1 LONG-LIFE

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

'TYPE AB' SELF-TAPPER

AutoCAD SHX Text

(3) PER PANEL @ INTERMEDIATE

AutoCAD SHX Text

FASTENER LOCATIONS

AutoCAD SHX Text

EAVE DETAILS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

PBR ROOF PANEL

AutoCAD SHX Text

EAVE TRIM

AutoCAD SHX Text

NOTE:

AutoCAD SHX Text

REFERENCE TYPICAL TRIM

AutoCAD SHX Text

LAP SECTIONS

AutoCAD SHX Text

AutoCAD SHX Text 1 3/4"

AutoCAD SHX Text 1/4-14 x 7/8" LONG-LIFE LAPTEK

AutoCAD SHX Text

W/WASHER @ 12" 0.C

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

INSIDE CLOSURE

AutoCAD SHX Text 1" x 3/32" TAPE SEALER

AutoCAD SHX Text

TOP & BOTTOM

AutoCAD SHX Text

OF CLOSURE

AutoCAD SHX Text

%%UEAVE SEALANT DETAIL

AutoCAD SHX Text

PBR ROOF PANEL

AutoCAD SHX Text

INSIDE CLOSURE

AutoCAD SHX Text

EAVE TRIM

AutoCAD SHX Text 1" x 3/32" TAPE SEALER

AutoCAD SHX Text

TOP & BOTTOM

AutoCAD SHX Text

OF CLOSURE

AutoCAD SHX Text 1" x 3/32" TAPE SEALER

AutoCAD SHX Text

SEAL TO TAPE

AutoCAD SHX Text

SEALER @ EAVE & SIDELAP

AutoCAD SHX Text 1/2" x 3/32" TAPE SEALER

AutoCAD SHX Text

@ PANEL SIDELAP

AutoCAD SHX Text 12-11 x 1 PANCAKE HEAD

AutoCAD SHX Text

SELF-TAPPER

AutoCAD SHX Text @ 5'-0" O.C.

AutoCAD SHX Text

WOOD FRAMING

AutoCAD SHX Text 1/4-14 x 1 LONG-LIFE

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

'TYPE AB' SELF-TAPPER

AutoCAD SHX Text

(6) PER PANEL

AutoCAD SHX Text

MOISTURE BARRIER

AutoCAD SHX Text

5/8" PLYWOOD MIN.

AutoCAD SHX Text

%%UPBR FASTENER SPACING @ INTERMEDIATE SUPPORTS

AutoCAD SHX Text

%%UPBR FASTENER SPACING @ PANEL ENDS

AutoCAD SHX Text 1/4-14 x 1 LONG-LIFE

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

'TYPE AB' SELF-TAPPER

AutoCAD SHX Text

MOISTURE BARRIER

AutoCAD SHX Text

23/32" RTD PLYWOOD SHEATHING

AutoCAD SHX Text 1/4-14 x 1 LONG-LIFE

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

'TYPE AB' SELF-TAPPER

AutoCAD SHX Text

MOISTURE BARRIER

AutoCAD SHX Text

5/8" PLYWOOD MIN.

AutoCAD SHX Text 9 1/2"

AutoCAD SHX Text 2 1/2"

AutoCAD SHX Text 2 1/2"

AutoCAD SHX Text

TRUSS

AutoCAD SHX Text 2x4 PURLINS

AutoCAD SHX Text

EAVE DETAILS OVER PLYWOOD ROOF DECK

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

PBR ROOF PANEL

AutoCAD SHX Text

INSTALL HI-TEMP METAL ROOF UNDERLAYMENT OVER PLYWOOD ONLY

AutoCAD SHX Text 1/4-14 x 1 LONG-LIFE

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

'TYPE AB' SELF-TAPPER

AutoCAD SHX Text

(5) PER PANEL

AutoCAD SHX Text EXISTING 2x6 @ EAVE

AutoCAD SHX Text EXISTING 2x6 FACIA BOARD @ EAVE

AutoCAD SHX Text EXISTING 2x4 TRIM BOARD @ EAVE

AutoCAD SHX Text

2" OVER HANG

AutoCAD SHX Text

DRIP EDGE GABLE END DRIP TO ALIGN WITH EAVE DRIP

AutoCAD SHX Text

EXISTING TRUSS

AutoCAD SHX Text

INSTALL 23/32" RTD PLYWOOD ROOF SHEATHING ONLY OVER ROOF AREAS INDICATED

AutoCAD SHX Text

PBR ROOF PANEL USE FULL LENGTH PANELS

AutoCAD SHX Text 1" x 3/32" TAPE SEALER

AutoCAD SHX Text

PBR ROOF PANEL

AutoCAD SHX Text 14-10 x 2 DECK SCREW

AutoCAD SHX Text

TRI-BEAD TAPE SEALER

AutoCAD SHX Text

URETHANE TUBE SEALANT

AutoCAD SHX Text

COUNTERFLASH

AutoCAD SHX Text

EXISTING BLOCK CHIMNEY

AutoCAD SHX Text

NOTE:

AutoCAD SHX Text

REFERENCE TYPICAL TRIM

AutoCAD SHX Text

LAP SECTIONS

AutoCAD SHX Text

MOISTURE BARRIER

AutoCAD SHX Text

23/32 RTD PLYWOOD

AutoCAD SHX Text

EXISTING WOOD FRAMING

AutoCAD SHX Text 1/4-14 x 1 LONG-LIFE

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

'TYPE AB' SELF-TAPPER

AutoCAD SHX Text

(5) PER PANEL

AutoCAD SHX Text

PARAPET RAKE TRIM

AutoCAD SHX Text 1/4-14 x 7/8" LONG-LIFE LAPTEK

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text @ 12" O.C.

AutoCAD SHX Text

CHIMNEY FLASHING DETAILS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

DO NOT DRILL INTO BRICK

AutoCAD SHX Text

CHIMNEY FLUE

AutoCAD SHX Text

EXISTING CROWN

AutoCAD SHX Text

COUNTERFLASHING TO BE INSTALLED AT LEAST 6" ABOVE ROOF PANELS

AutoCAD SHX Text 1/4-14 x 1 LONG-LIFE

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

'TYPE AB' SELF-TAPPER

AutoCAD SHX Text

(3) PER PANEL @ INTERMEDIATE

AutoCAD SHX Text

EAVE TRIM DETAIL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

EAVE TRIM OVER 23/32" PLYWOOD ROOF DECK AREA

AutoCAD SHX Text EAVE TRIM OVER 2"x4" PURLINS

AutoCAD SHX Text

EAVE TRIM MATERIAL SAME AS ROOF PANEL MATERIAL

AutoCAD SHX Text

[CUSTOM EAVE TRIM]

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING 3/4" VERTICAL SHIPLAP SIDING

AutoCAD SHX Text 1/4-14 x 7/8" LONG-LIFE LAPTEK

AutoCAD SHX Text

W/WASHER @ 12" 0.C.

AutoCAD SHX Text 1" x 3/32" TAPE SEALER

AutoCAD SHX Text

PBR ROOF PANEL

AutoCAD SHX Text

EXISTING TRUSS

AutoCAD SHX Text

VARIES

AutoCAD SHX Text

EXISTING 2X4 PURLINS

AutoCAD SHX Text

23/32" RTD SHEATHING

AutoCAD SHX Text

HIGH-TEMP UNDERLAYMENT TURN DOWN 3"

AutoCAD SHX Text

CONTINOUS CLEAT

AutoCAD SHX Text

GABLE END FLASHING

AutoCAD SHX Text 12 x 1 PANCAKE HEAD DRILLER @ 12" 0.C.

AutoCAD SHX Text

ALIGN DRIP WITH DRIP AT EAVES

AutoCAD SHX Text

GABLE END TRIM DETAIL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

NEW 23/32 RTD SHEATHING

AutoCAD SHX Text 1/4-14 x 1 LONG-LIFE

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

'TYPE AB' SELF-TAPPER

AutoCAD SHX Text

HIGH TEMP METAL UNDERLAYMENT

AutoCAD SHX Text

RIDGE VENT DETAIL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PBR ROOF PANEL

AutoCAD SHX Text 2"

AutoCAD SHX Text 1" x 3/32" TAPE SEALER

AutoCAD SHX Text

TOP & BOTTOM OF CLOSURE

AutoCAD SHX Text

OUTSIDE CLOSURE

AutoCAD SHX Text 1/4-14 x 7/8" LONG-LIFE LAPTEK

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

@ EA. HIGH RIB

AutoCAD SHX Text

PERFORATED VENT DRIP

AutoCAD SHX Text 1/4-14 x 7/8" LONG-LIFE LAPTEK

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text @ 6" O.C.

AutoCAD SHX Text

RIDGE TRIM

AutoCAD SHX Text

LAP

AutoCAD SHX Text

(MIN.)

AutoCAD SHX Text 1"

AutoCAD SHX Text

PERFORATED VENT DRIP

AutoCAD SHX Text

URETHANE SEALANT

AutoCAD SHX Text 1/4-14 x 1 LONG-LIFE

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

'TYPE AB' SELF-TAPPER

AutoCAD SHX Text

5/8" PLYWOOD MIN.

AutoCAD SHX Text

(NOT BY MBCI)

AutoCAD SHX Text

(6) PER PANEL

AutoCAD SHX Text

MOISTURE BARRIER

AutoCAD SHX Text

NOTE:

AutoCAD SHX Text

REFERENCE TYPICAL TRIM

AutoCAD SHX Text

LAP SECTIONS

AutoCAD SHX Text

HI-TEMP METAL ROOF UNDERLAYMENT

AutoCAD SHX Text

23/32" PLYWOOD

AutoCAD SHX Text

TRANSITION FROM PLYWOOD DECK TO PURLINS @ INTERMEDIATE SUPPORTS

AutoCAD SHX Text 1/2" x 3/32" TAPE SEALER

AutoCAD SHX Text

@ PANEL SIDELAP

AutoCAD SHX Text 1/4-14 x 7/8" LONG-LIFE LAPTEK

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text @ 20" O.C.

AutoCAD SHX Text 1/2" x 3/32" TAPE SEALER

AutoCAD SHX Text

@ PANEL SIDELAP

AutoCAD SHX Text

CUSTOM Z FLASHING FOR 3/4" DIFFERENCE IN HEIGHT

AutoCAD SHX Text 1/4-14 x 7/8" LONG-LIFE LAPTEK

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

EXISTING 2X4 PURLINS

AutoCAD SHX Text 1/4-14 x 1-1/2" LONG-LIFE

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

'TYPE AB' SELF-TAPPER

AutoCAD SHX Text

TRUSS

AutoCAD SHX Text

CUSTOM TRANSITION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text 1/4-14 x 1 LONG-LIFE

AutoCAD SHX Text

W/WASHER

AutoCAD SHX Text

'TYPE AB' SELF-TAPPER

AutoCAD SHX Text

EAVE CLOSURE DETAIL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

Sheets and Views
Model

File details come from the government source that posted it. Updated .