attachment_1_RFB DNCR CAP-2403.pdf
PDF 278 KB Posted
- Attached to
- Metal Roofing Replacement Pole Barn (NHQ02) North Country Resources Center Lancaster, NH
- Solicitation number
- RFB DNCR CAP-2403
- Issued by
- Coos County, New Hampshire
About this file
This document is a Request for Bid (RFB) issued by the State of New Hampshire Department of Natural and Cultural Resources for the metal roof replacement of a pole barn (NHQ02) located at the North Country Resources Center in Lancaster, New Hampshire.
The project entails stripping and removing the existing roofing materials, inspecting and repairing the wood purlins, installing new roof sheathing and a high-temperature metal roof underlayment, and installing a new PBR exposed fastener metal roof system including trim and flashing. The work also includes inspecting and repairing the existing chimney as necessary. The bid documents provide detailed specifications and drawings for the project scope of work.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFB DNCR CAP-2403.pdf | ||
| RFB DNCR CAP-2403_respondents.pdf | ||
| attachment_2_RFB DNCR CAP-2403.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
AutoCAD SHX Text
STATE OF NEW HAMPSHIRE
AutoCAD SHX Text
DEPARTMENT OF NATURAL AND CULTURAL RESOURCES
AutoCAD SHX Text
METAL ROOF REPLACEMENT
AutoCAD SHX Text
POLE BARN NHQ02
AutoCAD SHX Text
DESIGN, DEVELOPMENT & MAINTENANCE SECTION
AutoCAD SHX Text
OF
AutoCAD SHX Text
AutoCAD SHX Text
LANCASTER, NEW HAMPSHIRE
AutoCAD SHX Text
NORTH COUNTRY RESOURCES CENTER
AutoCAD SHX Text
EDWARD MUSSEY
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text 3/16"=1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
JUL 11, 2023
AutoCAD SHX Text
PROJECT #
AutoCAD SHX Text NOTES: 1. STRIP AND REMOVE ALL STRIP AND REMOVE ALL ROOFING MATERIALS. 2. INSPECT AND REPAIR WOOD PURLINS. 3. INSTALL RTD SHEATHING 2332 RTD SHEATHING IN AREAS INDICATED. 4. INSTALL HI-TEMP METAL ROOF UNDERLAYMENT OVER SHEATHING. 5. INSTALL NEW METAL ROOF PANELS. 6. INSPECT & REPAIR INSPECT & REPAIR CHIMNEY IF NECESSARY.
AutoCAD SHX Text
LINE OF BUILDING BELOW
AutoCAD SHX Text
INSTALL HIGH TEMP METAL ROOF UNDERLAYMENT OVER PLYWOOD ROOF SHEATHING
AutoCAD SHX Text INSTALL NEW PBR EXPOSED FASTENER METAL ROOF SYSTEM. USE FULL PANEL LENGTHS FROM RIDGE TO EAVE. (TYPICAL)
AutoCAD SHX Text
INSTALL METAL ROOF TRIM AT GABLE ENDS
AutoCAD SHX Text REPLACE MISSING 1"X 8" SHIP LAP OVER EXPOSED TRUSS MATCH DIMENSION AND SPECIES OF EXISTING SIDING.
AutoCAD SHX Text
INSPECT CHIMNEY AND REPOINT AS NECESSARY TO INSURE WATER-TIGHTNESS
AutoCAD SHX Text
INSTALL METAL ROOF DRIP EDGE AT EAVES
AutoCAD SHX Text
INSTALL 23/32" RTD PLYWOOD SHEATHING
AutoCAD SHX Text
EXISTING 2X4 PURLINS ~ @ 2'-0" O.C.
AutoCAD SHX Text
EXISTING 2X6 @ RIDGE
AutoCAD SHX Text
INTERIOR 2X4 WALL
AutoCAD SHX Text
INTERIOR 2X4 WALL
AutoCAD SHX Text
INTERIOR 2X4 WALL
AutoCAD SHX Text
EXISTING 2X6 @ EAVES
AutoCAD SHX Text
LIMITS OF PLYWOOD ROOF SHEATHING INSTALLATION
AutoCAD SHX Text
EXISTING 2X6 @ EAVE
AutoCAD SHX Text 8D COMMON OR DEFORMED NAIL (2-1/2"x0.131) OR RSRS-01 (2-3/8"x0.113") 6" O.C. AT PLYWOOD EDGES
AutoCAD SHX Text
LIMITS OF PLYWOOD ROOF SHEATHING INSTALLATION
AutoCAD SHX Text INSTALL 2"X4 BLOCKING AT GABLE ENDS BETWEEN EXISTING 2X4 PURLINS TO FASTEN PLYWOOD ROOF SHEATHING
AutoCAD SHX Text
EXISTING SHIPLAP VERTICAL SIDING
AutoCAD SHX Text
INSTALL NEW 1X6 AND 1X4 TRIM BOARDS AT GABLE END TO MATCH NORTH SIDE OF BUILDING
AutoCAD SHX Text
EXISTING VERTICAL SHIPLAP SIDING
AutoCAD SHX Text
EXISTING 1X6 GABLE BOARD
AutoCAD SHX Text
EXISTING 1X4 GABLE TRIM BOARD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NHQ02 POLE BARN ROOF PLAN
AutoCAD SHX Text
EXISTING 1"X3" FASCIA TRIM BOARD TO REMAIN
AutoCAD SHX Text
INSTALL NEW PBR METAL ROOF PANEL WITH EXPOSED FASTENERS
AutoCAD SHX Text
INSTALL METAL DRIPEDGE FLASHING @ EAVES
AutoCAD SHX Text
EXISTING TRUSS
AutoCAD SHX Text
EXISTING FASCIA BOARD TO REMAIN
AutoCAD SHX Text
INSTALL 23/32" RTD PLYWOOD ROOF SHEATHING OVER INDICATED AREA ONLY
AutoCAD SHX Text
EXISTING 3/4" SHIPLAP VERTICAL SIDING
AutoCAD SHX Text PROJECT NO. CAP-2403 METAL ROOF REPLACEMENT FOR THE POLE BARN NHQ02 AT THE NORTH COUNTRY RESOURCES CENTER 629 MAIN ST. LANCASTER, NH 03584
AutoCAD SHX Text 8D COMMON OR DEFORMED NAIL (2-1/2"x0.131) OR RSRS-01 (2-3/8"x0.113") 12" O.C. @ INTERMEDIATE SUPPORTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
CAP-2403
AutoCAD SHX Text INSTALL 2"X4" BLOCKING BETWEEN PURLINS AT GABLE ENDS OVER THE TOP CHORD OF THE TRUSS (TYPICAL)
AutoCAD SHX Text
RIDGE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3/16"=1'-0"
AutoCAD SHX Text
ROOF SECTION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NOTE: EDGES OF PLYWOOD SHEATHING SHOULD BE CENTERED OVER THE 2"X4" PURLINS. OTHERWISE USE SIMPSON STRONG TIE PSCL " CLIPS FOR 34" CLIPS FOR ADJOINING ADJACENT UNSUPPORTED PANELS.
| Sheets and Views |