attachment_1_RFB DNCR CAP-2403.pdf

PDF 278 KB Posted

Attached to
Metal Roofing Replacement Pole Barn (NHQ02) North Country Resources Center Lancaster, NH
Solicitation number
RFB DNCR CAP-2403
Issued by
Coos County, New Hampshire

About this file

This document is a Request for Bid (RFB) issued by the State of New Hampshire Department of Natural and Cultural Resources for the metal roof replacement of a pole barn (NHQ02) located at the North Country Resources Center in Lancaster, New Hampshire.

The project entails stripping and removing the existing roofing materials, inspecting and repairing the wood purlins, installing new roof sheathing and a high-temperature metal roof underlayment, and installing a new PBR exposed fastener metal roof system including trim and flashing. The work also includes inspecting and repairing the existing chimney as necessary. The bid documents provide detailed specifications and drawings for the project scope of work.

View the file

Other files

File Type Posted
RFB DNCR CAP-2403.pdf PDF
RFB DNCR CAP-2403_respondents.pdf PDF
attachment_2_RFB DNCR CAP-2403.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

AutoCAD SHX Text

STATE OF NEW HAMPSHIRE

AutoCAD SHX Text

DEPARTMENT OF NATURAL AND CULTURAL RESOURCES

AutoCAD SHX Text

METAL ROOF REPLACEMENT

AutoCAD SHX Text

POLE BARN NHQ02

AutoCAD SHX Text

DESIGN, DEVELOPMENT & MAINTENANCE SECTION

AutoCAD SHX Text

OF

AutoCAD SHX Text

AutoCAD SHX Text

LANCASTER, NEW HAMPSHIRE

AutoCAD SHX Text

NORTH COUNTRY RESOURCES CENTER

AutoCAD SHX Text

EDWARD MUSSEY

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text 3/16"=1'-0"

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

JUL 11, 2023

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text NOTES: 1. STRIP AND REMOVE ALL STRIP AND REMOVE ALL ROOFING MATERIALS. 2. INSPECT AND REPAIR WOOD PURLINS. 3. INSTALL RTD SHEATHING 2332 RTD SHEATHING IN AREAS INDICATED. 4. INSTALL HI-TEMP METAL ROOF UNDERLAYMENT OVER SHEATHING. 5. INSTALL NEW METAL ROOF PANELS. 6. INSPECT & REPAIR INSPECT & REPAIR CHIMNEY IF NECESSARY.

AutoCAD SHX Text

LINE OF BUILDING BELOW

AutoCAD SHX Text

INSTALL HIGH TEMP METAL ROOF UNDERLAYMENT OVER PLYWOOD ROOF SHEATHING

AutoCAD SHX Text INSTALL NEW PBR EXPOSED FASTENER METAL ROOF SYSTEM. USE FULL PANEL LENGTHS FROM RIDGE TO EAVE. (TYPICAL)

AutoCAD SHX Text

INSTALL METAL ROOF TRIM AT GABLE ENDS

AutoCAD SHX Text REPLACE MISSING 1"X 8" SHIP LAP OVER EXPOSED TRUSS MATCH DIMENSION AND SPECIES OF EXISTING SIDING.

AutoCAD SHX Text

INSPECT CHIMNEY AND REPOINT AS NECESSARY TO INSURE WATER-TIGHTNESS

AutoCAD SHX Text

INSTALL METAL ROOF DRIP EDGE AT EAVES

AutoCAD SHX Text

INSTALL 23/32" RTD PLYWOOD SHEATHING

AutoCAD SHX Text

EXISTING 2X4 PURLINS ~ @ 2'-0" O.C.

AutoCAD SHX Text

EXISTING 2X6 @ RIDGE

AutoCAD SHX Text

INTERIOR 2X4 WALL

AutoCAD SHX Text

INTERIOR 2X4 WALL

AutoCAD SHX Text

INTERIOR 2X4 WALL

AutoCAD SHX Text

EXISTING 2X6 @ EAVES

AutoCAD SHX Text

LIMITS OF PLYWOOD ROOF SHEATHING INSTALLATION

AutoCAD SHX Text

EXISTING 2X6 @ EAVE

AutoCAD SHX Text 8D COMMON OR DEFORMED NAIL (2-1/2"x0.131) OR RSRS-01 (2-3/8"x0.113") 6" O.C. AT PLYWOOD EDGES

AutoCAD SHX Text

LIMITS OF PLYWOOD ROOF SHEATHING INSTALLATION

AutoCAD SHX Text INSTALL 2"X4 BLOCKING AT GABLE ENDS BETWEEN EXISTING 2X4 PURLINS TO FASTEN PLYWOOD ROOF SHEATHING

AutoCAD SHX Text

EXISTING SHIPLAP VERTICAL SIDING

AutoCAD SHX Text

INSTALL NEW 1X6 AND 1X4 TRIM BOARDS AT GABLE END TO MATCH NORTH SIDE OF BUILDING

AutoCAD SHX Text

EXISTING VERTICAL SHIPLAP SIDING

AutoCAD SHX Text

EXISTING 1X6 GABLE BOARD

AutoCAD SHX Text

EXISTING 1X4 GABLE TRIM BOARD

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NHQ02 POLE BARN ROOF PLAN

AutoCAD SHX Text

EXISTING 1"X3" FASCIA TRIM BOARD TO REMAIN

AutoCAD SHX Text

INSTALL NEW PBR METAL ROOF PANEL WITH EXPOSED FASTENERS

AutoCAD SHX Text

INSTALL METAL DRIPEDGE FLASHING @ EAVES

AutoCAD SHX Text

EXISTING TRUSS

AutoCAD SHX Text

EXISTING FASCIA BOARD TO REMAIN

AutoCAD SHX Text

INSTALL 23/32" RTD PLYWOOD ROOF SHEATHING OVER INDICATED AREA ONLY

AutoCAD SHX Text

EXISTING 3/4" SHIPLAP VERTICAL SIDING

AutoCAD SHX Text PROJECT NO. CAP-2403 METAL ROOF REPLACEMENT FOR THE POLE BARN NHQ02 AT THE NORTH COUNTRY RESOURCES CENTER 629 MAIN ST. LANCASTER, NH 03584

AutoCAD SHX Text 8D COMMON OR DEFORMED NAIL (2-1/2"x0.131) OR RSRS-01 (2-3/8"x0.113") 12" O.C. @ INTERMEDIATE SUPPORTS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

CAP-2403

AutoCAD SHX Text INSTALL 2"X4" BLOCKING BETWEEN PURLINS AT GABLE ENDS OVER THE TOP CHORD OF THE TRUSS (TYPICAL)

AutoCAD SHX Text

RIDGE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 3/16"=1'-0"

AutoCAD SHX Text

ROOF SECTION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text NOTE: EDGES OF PLYWOOD SHEATHING SHOULD BE CENTERED OVER THE 2"X4" PURLINS. OTHERWISE USE SIMPSON STRONG TIE PSCL " CLIPS FOR 34" CLIPS FOR ADJOINING ADJACENT UNSUPPORTED PANELS.

Sheets and Views
Model

File details come from the government source that posted it. Updated .