This document includes photos and details for renewing an aged photovoltaic system at the Polebridge Generator Building in Glacier National Park. The National Park Service is soliciting proposals under solicitation number 140P1424Q0004 to remove failed battery racks and components, commission backup generators, construct a partition wall, and install new batteries at the generator building. Photos depict the existing solar panel arrays, generator building interior and components to be removed including batteries, generators, ventilation fans and oil drums. The opportunity aims to upgrade the aged system prior to the 2023-2024 season at the Polebridge Ranger Station in Montana.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RENEW POLRBDIGE PHOTOVOLTAIC
SYSTEM COMPONENTS
SITE PHOTOS
AUGUST TO OCTOBER 2023
Location
Polebridge area Polebridge Ranger area
Polebridge Mercantile and townsite
Polebridge Ranger area
North Fork Flathead River bridge
Solar arrays
Ranger Station 714 Glacier Dr Polebridge MT 59928
B#1449 Generator Building
Existing Solar Panel Arrays
SolarWorld SW340XL 340 Watt Photovoltaic Panels x 30 (not involved in this contract)
B#1449 Polebridge Generator Building
B#1449 Generator Building, including parking/staging area outside of building
Backup generators in enclosure, to be commissioned prior to start of this contract
Floor plan with proposed partition wall in red
Partition wall and door to be constructed by NPS
Photo from building entry showing approximate partition wall alignment
View from front doors View facing front doors
Batteries to be removed by contract
Generator to be removed by
NPS
Defunct generator to be removed by NPS
Schneider XW Ventilation fan to be removed by NPS
View facing wall to right of doors View facing wall to left of doors
Oil drums to be removed by
NPS
Ventilation fan to be removed by NPS
Batteries to be removed by contract
Schneider XW
Failed battery rack, Outback EnergyCell 2700RE Failed battery safety sticker
Failed battery rack, Outback EnergyCell 2700RE Failed battery rack, Outback EnergyCell 2700RE
Schneider XW System
Conext AGS units and SCP Schneider Conext SCP and InsightHome
| RENEW POLRBDIGE PHOTOVOLTAIC SYSTEM COMPONENTS |
| Location |
| Existing Solar Panel Arrays |
| B#1449 Polebridge Generator Building |
| B#1449 Polebridge Generator Building |
| B#1449 Polebridge Generator Building |
| B#1449 Polebridge Generator Building |
| B#1449 Polebridge Generator Building |
| B#1449 Polebridge Generator Building |
| B#1449 Polebridge Generator Building |
| B#1449 Polebridge Generator Building |
File details come from the government source that posted it. Updated .