Attachment_2_-_Intake_3_Sketch.pdf

PDF 2 MB Posted

Attached to
Diving Services for Coleman National Fish Hatchery
Solicitation number
140R2024Q0066
Issued by

About this file

This document appears to be an attachment, titled "Attachment_2_-_Intake_3_Sketch.pdf", that contains detailed engineering drawings and specifications for a new concrete structure.

The related federal contract opportunity is a Request for Quote (RFQ) solicitation from the Department of the Interior Bureau of Reclamation for Diving Services at the Coleman National Fish Hatchery. The solicitation has a period of performance from May 1, 2024 to July 31, 2024, and quotes are due by March 28, 2024. The acquisition is set aside for small businesses under NAICS code 561990 with a $16.5 million size standard. The solicitation incorporates standard commercial item provisions and clauses, including evaluation criteria. Interested vendors should submit their pricing information per the instructions.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D

C

B

A

� Q .. <>: � �K

;:e' ��

214-0-25757 b . I a

Platform and supports not shown---...

NEW STRUCTURE

Seven #7 bars arranged as shown -�ft:_�_;..�

Troshrock not shown ef

#7@1-0 ew 10'-0"

Eight #7 bars arranged

2'-0"

I l()

#7@1-0-------

. . . 0

#7@1-0

15" chamfer

-· o - ·o

- -• 0 . 0 r;j - . · •.

• -_ - "' - 0 .. 0 . _ . •

. . . o le=.= • . . 0 .

-�"f--,---._.

-__ • - o·. - .

.. 0 . _.

Embedded guides (25829)

- 0 ·_ • • 0

·h·t-+-#7@1-0 ew• 4?

o·

DETAIL 1A (25756)

SECTIONAL PLAN, EL. 450

. ·. O _·

_i----'--z-,--,i--t---#7@1-0

0 . •

• 0 .

.. _ . . _o

0 • • •

#7@1-0'____,,c,�e-;, • • • ·. ·_o • •

• • • 0

15" chamfer . • 0

0 - - 0 0

. 0 0 . - .

. • 0 • • 0 0 - - 4?

DETAIL 18 (25155J

SECTIONAL PLAN, EL. 459

Existing fish ladder wall, 42'-0"

Embedded guides

(25829), (TYP) ----

#7@1-0 #7@6

_o . . 0

• 0

. 0 -·_.

_ • •. ·_o -o

. 0 . • . . .

- -o

• 0 - -·• • 0 .

: _-:-0 ·-·o·: _-:-

- . . 0 . . .

o· - _ - 9 o·

0 • - • -

• • • . 0

Embedded guides (25829)

#7@1-0 i,..+---#7@6----.

o�,--

·o

• ·_._-_o·.·

#7@1-Q--,.-._ .0 _ ·_. • :- .• .

#7@1-0

O · -·O .

4?

o·

• ·o ·

0 • • • . .

0 . - "'

I .

• 0 . - - 0 .

� • _o . - " •

•. _ . . r, . I

DETAIL 4 (25756)

SECTIONAL PLAN, EL. 458

Contractor to ensure integrity of existing wall during placement of new concrete.

Woll toper, cost against existing wall, 16'-0"

NEW STRUCTURE

Wall toper 5'-0 11 a

.I 0)

#7@1-0

- - o -· • . o -

-. __ -·_o _- _o· _

==II. ·• .. 0 . :

o_ - _o -_ . - o_ -_o

�- - � o· • 0 • - • -

.. . . 0 - . 0,

· · o-

- ·o. · ·o - 0 - - - 0 •

• 0:

• • .. _ r,j !

. • 0:

_- ": • · o • • • • · o

• 0 •. • -·.- ·- 0 •• •

Embedded guides

(25829), (TYP)

.: ··•. ·._o_: ··•.l-+-·-#7@1-0 ew,ef

-o - b - . - -o-

- 0 -·o· • -·o· o - - o o· - -• o•·_ .· _-- o·· o - 0 - . - o - O-·o· ·.-·o· . . 4? 0 -o· . • - o· . .

. - o - · o

. • . - 0 .

- 0

- 0 -

. 0 -

• o:

.. _ o· ! - · • o:

• ·a,· _ ·_o_

·_o •

._o _ :_ ·_·•

. - o · O · - · O • -·o· · .-·o· 0 _. <.? 0 o· . • . o· . . . . .,. . - o - · •. - .• 0 .

#7@6 �--- I �+-e---f

---;:-l _- 0 o • • • •• 0 o ··c......,--+-��---:--i I • 0 •

• • • "'· 0 • • • • .,._ -0 _.,, . _ . _ _ .,, . _ . . . . ,, . _ a, · _ _ o_ ·--_ ... •

._ o_ ·--_ ... - . · a, -_ _ o ·--_ . . 0- __ o_ o o ·_ :o" _ o o ··_ :0_ o

•-o·_ :0_ o

_ _ 0 _ • -·o· · .-·o· · .-·o· o-. - - o- . - . o· a,- _ . .

-e--<- -. . -_ 0

. 0 . -- . - ...

as show�=���Ll--- #5 anchor bars _L_ El. 444.86 located in center of wall @1-0

Begin dowel bars 4'-0" ff, at contact between existing wall and new wall taper

12'-0"

DETAIL 3 (25756)

SECTIONAL PLAN, EL. 458

1 1"

El.

436.11

Crest gate (25858)

,___-ef, existing wall reinforcement not shown

-+--.-,ft---t I - I I I I I I I I I I I

2'- " I

El. 436. 11 (begin slope)

S=-0.05,--a #7@1-0 ew . I •..

l()

--I

0 . - • - . - 0 . . .

. . 0

For reinforcement pattern, see 40-D-6263

0 . - ..

o -_

_o

-. ci

2¾"

�,, Dia.x4" long headed anchors, weld to angle.

Space on 12" max. centers o· o • . . _ o:

- _"':o- �-- •

·a.· ·_o _ ---_ ... -_ •0-_ _ o _ - --_.

- ·• -.ci . -· - ·• -.o·

DETAIL 2 (25756)

SECTIONAL PLAN, EL. 440

NO SCALE

#7@6

Fish ladder baffles (TYP)

I I I I � I I I I I I I I I I I I I I I I I I New floor I I I I #7@1_0 1

I I I I I

I I

Start of wall taper--_, SECTION A-A

1 0 2 3 4 5

I I I ii I I I I

SCALE OF FEET

#5 dowe: bars �on a 2'-0" grid

Existing ladder floor ef

1-1 I I I I I I I I I I

End dowel bars

#5@1-0 I

I r-

1 I

I I I

_J

4'-6" El. 442.86 1'-611

.---- End of wall taper ef \ ,.-,4--... #5@ 1 -0

't Double leaf

't Stoplog slots sf ide gate---+---i b

2: 1

1---+-+-#7@1-0

El. 433.86

#7@1-0

17'-0"

.I 0)

_I

#7@6

REV NO 20014-07-07 AS-BUILT. EXTENDED ABUTMENT WALL TO ACCOMMODATE CREST GATE.

R. A. WELCH P.£.

R. A. WELCH P.£. SPECIFICATIONS 3 20-C0700

REV NO

2008-0 1- 18 DELETED DETAILS 1 AND 2, CREATED DETAIL IA ANO IB,

D - SJR P.£. ADDED INLET TRASHRACK WALLS.

S. Robertson

EB ALWAYS THINK SAFETY

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF RECLAMATION

CENTRAL VALLEY PROJECT - CALIFORNIA

SHASTA DIVISION

COLEMAN NATIONAL FISH HATCHERY

WATER SUPPLY INTAKE REHABILITATION

SCREENED INTAKE 3 - STRUCTURE

SECTION AND DETAILS

DESIGNED __ J_3SJ"!_ 'l!_A!i_N�R ____ CHECKED ___ �T�N _JiM� _Rq_BE_R!_Sq_N _ _ _

DRAWN _ __ _.iA_JO.!.J _WiG"l_E/i ___ _ TECH. APPR. __ SJfl!E!! _iA}!EJ !]O�f!!�O_!.',_P:f. _

STEVEN JAMES ROBERTSON, P.E.

APPROVED _ DAVID K. EDWARDS, P.£. ____ _

PEER REVIEWER - lM� K. EDWARD$, P.E., UANAGER WA1FR CONVcYANCC GROUP �C::::. _. I vi ,'.S Ci: 7' DENVER, COLORADO November 9, 2007 21 4-0-2 5 7 5 7 ����L------------------------------,------------------------------,---------

--------------------------_j_

T ___ ����=U-=-2 �0�F �10=------'------------�

5 4 3 2

D

C

B

A

File details come from the government source that posted it. Updated .