This is a technical engineering drawing for a Vogelsang USA rotary lobe pump assembly. The drawing, dated November 8, 2025, specifies a VX100-128Q pump type paired with a USEM0674 motor, GBO.026.T1 base plate, and GZS.018 belt guard with new connectors. The pump is configured for sludge crossover applications with 1% solids handling capability, rated at 90 gallons per minute at 12 psi (27.65 feet of head) and approximately 450 pounds total weight.

The technical specifications include detailed dimensional requirements with fabrication tolerances of ±0.12 inches, flange load limits (450 N horizontal and vertical allowable loads, 125 Nm allowable bending moment), and connector specifications per ASME B16.5 standards. Critical maintenance access requirements are documented, specifying a minimum 20-inch recommended clearance (W dimension) on one side and 28 inches minimum with 39 inches recommended on the other side. The drawing provides multiple orthogonal views, dimensional callouts, and a three-dimensional isometric representation to clearly communicate assembly configuration and spatial requirements to fabrication and installation personnel.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A A

B B

C C

D D

R: A00 date: 11.08.2025 date:

drawn by: Klaus checked by:

drawing no.:

changes of dimensions reserved dimensions without indication of tolerances acc. to DIN ISO 2768-v www.vogelsangusa.com dimensions shown in inches fabrication tolerance is ± .12"

Vogelsang USA

7966 State Route 44

P. O. Box 751

Ravenna, OH 44266 USA

© Vogelsang GmbH & Co. KG

IB2513166

X

Z

Y

W

Attention space required for maintenance work

W = 28 inch min., 39 inch recommended

Pump Type:

VX100-128Q

Motor: USEM0674

Base Plate: GBO.026.T1

Belt Guard: GZS.018

Connectors:

new

W

Attention space required for maintenance work

W = 20 inch recommended allowable horizontal flange load: 450 N allowable vertical flange load: 450 N allowable flange bending moment: 125 Nm

14.90

36.42

15.94

11.22

5.51 16.54

14.71 n0.71

13.58 1.18

RightLeft

~450 Ibs

11.57

14.17

36.97

12731400 - Pos 1.0 Rotary Lobe crossover / Sludge, No specifics /

1 % Solids / 90 gpm @ 12 psi (27.65 ft of head)

Sketch