Attachment 1(a) - ZLC NEMC HVAC and Electrical Upgrades - Drawings.pdf
PDF 8 MB Posted
- Solicitation number
- 697DCK-23-R-00120
About this file
This document package includes drawings and specifications for an upcoming Federal Aviation Administration project for HVAC and electrical upgrades at the NAS Enterprise Management Center located at the Salt Lake City Air Route Traffic Control Center in Salt Lake City, Utah. The project magnitude is estimated between $250,000 and $500,000. A pre-bid site visit is scheduled for February 22, 2023 and requests for information or clarification are due by March 1, 2023. Offers must be submitted by March 8, 2023 and shall be emailed with total file size less than 10MB due to FAA email restrictions. The package outlines the scope of work including mechanical, electrical and control system replacements and upgrades.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
2022-11-22T14:17:00-0800
DONALD E SCHMEICHEL
2022-11-29T07:25:13-0800
CALLEN R COLLINS
2022-11-22T14:17:50-0800
DONALD E SCHMEICHEL
2022-11-29T07:22:58-0800
CALLEN R COLLINS
2022-11-22T14:19:25-0800
DONALD E SCHMEICHEL
2022-11-29T07:38:31-0800
CALLEN R COLLINS
2022-11-22T14:20:06-0800
DONALD E SCHMEICHEL
2022-11-29T07:52:32-0800
CALLEN R COLLINS
2022-11-22T14:21:02-0800
DONALD E SCHMEICHEL
2022-11-29T07:51:16-0800
CALLEN R COLLINS
2022-11-22T14:21:46-0800
DONALD E SCHMEICHEL
2022-11-29T07:49:49-0800
CALLEN R COLLINS
2022-11-22T14:23:17-0800
DONALD E SCHMEICHEL
2022-11-29T07:48:31-0800
CALLEN R COLLINS
2022-11-22T14:23:59-0800
DONALD E SCHMEICHEL
2022-11-29T07:47:00-0800
CALLEN R COLLINS
2022-11-22T14:24:55-0800
DONALD E SCHMEICHEL
2022-11-29T07:45:43-0800
CALLEN R COLLINS
DRAWING NUMBER DESCRIPTION
SLC‐22004645‐G001 COVER SHEET, VICINITY MAP AND DRAWING INDEX
SLC‐22004645‐G002 ELECTRICAL AND MECHANICAL LEGEND
SLC‐22004645‐G003 GUIDE PLANS ‐ FIRST AND SECOND FLOORS
SLC‐22004645‐A102 FIRST FLOOR EQUIPMENT ROOM PLAN ‐ DEMOLITION
SLC‐22004645‐A202 FIRST FLOOR EQUIPMENT ROOM PLAN
SLC‐22004645‐A501 WALL DETAILS
SLC‐22004645‐M102 FIRST FLOOR EQUIPMENT ROOM MECHANICAL PLAN ‐ DEMOLITION
SLC‐22004645‐M111 SECOND FLOOR MECHANICAL ROOM PLAN ‐ DEMOLITION
SLC‐22004645‐M112 SECOND FLOOR EQUIPMENT ROOM MECHANICAL PLAN ‐ DEMOLITION
SLC‐22004645‐M202 FIRST FLOOR EQUIPMENT ROOM MECHANICAL PLAN
SLC‐22004645‐M212 SECOND FLOOR EQUIPMENT ROOM MECHANICAL PLAN
SLC‐22004645‐M501 MECHANICAL EQUIPMENT DETAILS
SLC‐22004645‐M601 MECHANICAL SCHEDULES
SLC‐22004645‐E102 FIRST FLOOR EQUIPMENT ROOM POWER DEMOLITION PLAN
SLC‐22004645‐E112 SECOND FLOOR EQUIPMENT ROOM POWER DEMOLITION PLAN
SLC‐22004645‐E201 FIRST FLOOR MECHANICAL AND TELCO ROOM POWER PLAN
SLC‐22004645‐E202 FIRST FLOOR EQUIPMENT ROOM POWER PLAN
SLC‐22004645‐E211 SECOND FLOOR MECHANICAL AND TELCO ROOM POWER PLAN
SLC‐22004645‐E212 SECOND FLOOR EQUIPMENT ROOM POWER PLAN
SLC‐22004645‐E501 KIRK KEY PANEL AND CONDUIT DETAILS
SLC‐22004645‐E502 ELECTRICAL DETAILS
SLC‐22004645‐E701 ELECTRICAL ONE‐LINE DIAGRAMS ‐ CRITICAL POWER
SLC‐22004645‐E702 ELECTRICAL ONE‐LINE DIAGRAMS ‐ CRITICAL POWER BRANCH CIRCUITS
SLC‐22004645‐E801 CRITICAL PANEL SCHEDULES NC‐225‐A & NC‐225‐B
SLC‐22004645‐E802 CRITICAL PANEL SCHEDULES NC‐113‐A & NC‐113‐B
SLC‐22004645‐E803 CRITICAL PANEL SCHEDULES NC‐113‐F & NC‐113‐F
SLC‐22004645‐E804 BUILDING SERVICE PANEL SCHEDULES NB‐120‐A, NB‐225‐A & NE‐225‐A
SLC‐22004645‐Z102 FIRST FLOOR EQUIPMENT ROOM TEMPORARY COOLING PLAN
SLC‐22004645‐Z112 SECOND FLOOR EQUIPMENT ROOM TEMPORARY COOLING PLAN
DRAWING INDEX
2022-11-22T14:26:13-0800
DONALD E SCHMEICHEL
2022-11-29T07:44:21-0800
CALLEN R COLLINS
2022-11-22T14:26:56-0800
DONALD E SCHMEICHEL
2022-11-29T07:43:09-0800
CALLEN R COLLINS
2022-11-22T14:28:48-0800
DONALD E SCHMEICHEL
2022-11-29T07:41:43-0800
CALLEN R COLLINS
2022-11-22T14:29:57-0800
DONALD E SCHMEICHEL
2022-11-29T10:12:28-0800
CALLEN R COLLINS
2022-11-22T14:30:45-0800
DONALD E SCHMEICHEL
2022-11-29T10:05:27-0800
CALLEN R COLLINS
2022-11-22T14:32:59-0800
DONALD E SCHMEICHEL
2022-11-29T10:10:54-0800
CALLEN R COLLINS
2022-11-22T14:33:41-0800
DONALD E SCHMEICHEL
2022-11-29T10:06:36-0800
CALLEN R COLLINS
2022-11-22T14:34:21-0800
DONALD E SCHMEICHEL
2022-11-29T10:08:05-0800
CALLEN R COLLINS
2022-11-22T14:35:18-0800
DONALD E SCHMEICHEL
2022-11-29T10:09:32-0800
CALLEN R COLLINS
HP VOLTS PH HZ # FANS TOTAL
(MBH)
SENS.
(MBH) EDB ( ̊F) EWB ( ̊F) LDB ( ̊F) LWB ( ̊F) GPM ENT ( ̊F) LWT ( ̊F) TOTAL (MBH) GPM PRESSURE
DROP PSI TEMP DROP KW LBS/HR MFGR. MODEL/ SERIES
N-CRAC-1 113 113 17,200 0.30 DIRECT - 4.1 460 3 60 3 341 322 72 60 73 45 55 190 19.5 19.5 20F 6.8 20 13.00 5 STULZ CCD-1800-CWE
N-CRAC-2 113 113 17,200 0.30 DIRECT - 4.1 460 3 60 3 341 322 72 60 73 45 55 190 19.5 19.5 20F 6.8 20 13.00 5 STULZ CCD-1800-CWE
N-CRAC-5 224 224 17,200 0.30 DIRECT - 4.1 460 3 60 3 341 322 72 60 73 45 55 190 19.5 19.5 20F 6.8 20 13.00 5 STULZ CCD-1800-CWE
N-CRAC-6 224 224 17,200 0.30 DIRECT - 4.1 460 3 60 3 341 322 72 60 73 45 55 190 19.5 19.5 20F 6.8 20 13.00 5 STULZ CCD-1800-CWE
AIR HANDLING UNIT SCHEDULE
UNIT NO. CAPACITY WATER REMARKS
SUPPLY FAN DATA
AIR
COOLING COIL DATA KNOWN ACCEPTIBLE
SOURCESLOCATION AREA
SERVICED ESP (IN
W.G.) DRIVE
HUMIDIFICATION
RPM
SUPPLY
AIR
(CFM)
NOTE:
1. PROVIDE DOWN DISCHARGE UNITS WITH SEISMICALLY CERTIFIED FLOOR STANDS, FACTORY INSTALLED DISCONNECT SWITCH, CONDENSATE PUMP, SMOKE DETECTOR, CANISTER TYPE HUMIDIFIER, AND FACTORY NETWORK CONTROLLER.
2. UNITS SHALL UTILIZE FAN SETTINGS TO OBTAIN REQUIRED CFM AIR PROPERTIES AND TUNED GPM TO OBTAIN REQUIRED COOLING CAPACITY.
3. UNITS SHALL UTILIZE ONBOARD LEAK DETECTION AND ALARM TO BAS.
SUPPLY FAN(S) MOTOR DATA
NOTE 1, 2
FILTER SCHEDULE
MERV
EFF SIZEQTY
HEATING COIL DATA
23x32x4 (5)
CAPACITY
2022-11-22T14:35:53-0800
DONALD E SCHMEICHEL
2022-11-29T13:51:05-0800
CALLEN R COLLINS
2022-11-22T14:37:02-0800
DONALD E SCHMEICHEL
2022-11-29T13:46:03-0800
CALLEN R COLLINS
2022-11-22T14:32:13-0800
DONALD E SCHMEICHEL
2022-11-29T13:50:32-0800
CALLEN R COLLINS
2022-11-22T14:07:26-0800
DONALD E SCHMEICHEL
2022-11-29T07:20:08-0800
CALLEN R COLLINS
2022-11-22T14:09:40-0800
DONALD E SCHMEICHEL
2022-11-29T07:37:16-0800
CALLEN R COLLINS
2022-11-22T14:10:30-0800
DONALD E SCHMEICHEL
2022-11-29T07:35:59-0800
CALLEN R COLLINS
2022-11-22T14:11:47-0800
DONALD E SCHMEICHEL
2022-11-29T07:31:06-0800
CALLEN R COLLINS
2022-11-22T14:12:54-0800
DONALD E SCHMEICHEL
2022-11-29T07:32:14-0800
CALLEN R COLLINS
2022-11-22T14:14:33-0800
DONALD E SCHMEICHEL
2022-11-29T07:34:22-0800
CALLEN R COLLINS
2022-11-22T14:15:31-0800
DONALD E SCHMEICHEL
2022-11-29T07:28:22-0800
CALLEN R COLLINS
2022-11-22T14:16:18-0800
DONALD E SCHMEICHEL
2022-11-29T07:26:41-0800
CALLEN R COLLINS
File details come from the government source that posted it. Updated .