Attachment 13 - Telecommunications Drawings 626-700.TN.20240308.pdf

PDF 25 MB Posted

Attached to
Y1DZ--626-22-700 EHRM Infrastructure Upgrades Construction Nashville
Solicitation number
36C77624B0029
Issued by

About this file

This document appears to be Attachment 13 - Telecommunications Drawings 626-700.TN.20240308.pdf, which is related to the federal contract opportunity with Solicitation Number 36C77624B0029 for EHRM Infrastructure Upgrades Construction at the Nashville VAMC, issued by the Department of Veterans Affairs Technology Acquisition Center Austin.

The attachment appears to contain technical drawings for telecommunications systems as part of the infrastructure upgrades at the Nashville VAMC. The drawings cover items numbered 626 through 700. No further details about the required products or services are provided in this attachment. This appears to be a technical appendix to the overall solicitation rather than a document that outlines the specific requirements.

View the file

Other files

File Type Posted
Redacted Abstract of Bids OF 1419 - Nashville EHRM.pdf PDF
36C77624B0029 0006.docx DOCX document
36C77624B0029 0005.docx DOCX document
Technical Question Tracker - FINAL.pdf PDF
36C77624B0029 0004.docx DOCX document
36C77624B0029 0003.docx DOCX document
S06 - Technical Questions Tracking Spreadsheet.pdf PDF
S06 - Geotech Boring.pdf PDF
36C77624B0029 0002.docx DOCX document
36C77624B0029 0001.docx DOCX document
Site Visit Attachment.pdf PDF
Attachment 2 - Specifications VOL 1 - Revised.pdf PDF
Attachment 3 - Specifications VOL 2 - Revised.pdf PDF
Attachment 1 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 15 - Site Visit Instructions.pdf PDF
Attachment 11 - Sheet Index Drawings 626-700.SHEET INDEX.20240308.pdf PDF
Attachment 7 - Fire Protection Drawings 626-700.FX.20240308.pdf PDF
Attachment 12 - Structural Drawings 626-700.SF.20240308.pdf PDF
36C77624B0029.docx DOCX document
Attachment 6 - Electrical Drawings 626-700.EP.20240308.pdf PDF
Attachment 10 - Plumbing Drawings 626-700.PL.20240308.pdf PDF
Attachment 9 - Mechanical Drawings 626-700.MH.20240308.pdf PDF
Attachment 8 - General Drawings 626-700.GI.20240308.pdf PDF
Attachment 4 - Architectural Drawings 626-700.AE.20240308.pdf PDF
Attachment 5 - Civil Drawings 626-700.CS.20240308.pdf PDF
Attachment 14 - WDTN20230178 MOD 3 - 7-26-2024.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A. REFER TO VA OIT "INFRASTRUCTURE STANDARD FOR TELECOMMUNICATIONS SPACES VERSION 3.1" FOR ADDITIONAL REQUIREMENTS INCLUDING MANUFACTURER AND MODEL NUMBERS FOR THE BASIS OF DESIGN EQUIPMENT. ALL EQUIPMENT PROVIDED AS PART OF THIS PROJECT MUST BE EQUIVALENT TO THE

BASIS OF DESIGN EQUIPMENT LISTED.

B. FOR ALL CONDUIT AND OTHER ITEMS PENETRATING A FIRE RATED WALL, PROVIDE UL LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM, INSTALLED BY A CERTIFIED INSTALLER, THAT IS SPECIFIC TO THE WALL CONSTRUCTION ASSEMBLY AND COMPLIANT WITH ASTM E814. INSTALL SYSTEM IN STRICT COMPLIANCE WITH THE FIRE STOPPING MANUFACTURER’S U.L. APPROVED DETAIL. WHERE EXISTING WALLS ARE BEING UPGRADED TO FIRE RATED WALLS OR THE FIRE RATING IS BEING MODIFIED, PROVIDE U.L. LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM FOR ALL NEW AND EXISTING PENETRATIONS.

REFER TO THE ARCHITECTURAL LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED WALLS.

C. PROVIDE ADDITIONAL SUPPORTS AS REQUIRED TO INDEPENDENTLY SUPPORT ALL EXISTING TO REMAIN

CABLING.

D. PROVIDE ONE (1) CATEGORY 6A CABLE TO EACH UPS WITHIN PROJECT. CENTRALIZED UPS'S ARE SHOWN

ON THE ELECTRICAL DRAWING SET AND RACK MOUNTED UPS'S ARE SHOWN ON THE

TELECOMMUNICATIONS ROOM RACK ELEVATIONS FOR EACH ROOM. UPS'S SHALL BE CONNECTED

TOGETHER IN A CENTRALIZED UPS MONITORING SYSTEM.

E. PROVIDE TWO (2) CATEGORY 6A CABLE TO EACH POWER DISTRIBUTION UNIT (PDU) ON THE BACK OF EACH

ACTIVE RACK.

F. PROVIDE ONE (1) CATEGORY 6A CABLE TO EACH NEW PANELBOARD, DISTRIBUTION BOARD, AND

SWITCHBOARD WITHIN PROJECT. PANELS SHALL BE CONNECTED TOGETHER IN A CENTRALIZED

ELECTRICAL METERING SYSTEM.

G. ALL CABLING, CONDUITS, CHASEWAYS, PANELS, BOXES AND EQUIPMENT ARE TO BE LABELED UTILIZING

THE LATEST IN BICSI/TIA STANDARDS.

H. ALL NEW CONSTRUCTION TRS ARE TO GET NEW ACCESS CONTROL PANELS FROM THE CURRENT VENDOR.

THE CONTRACTOR WILL COORDINATE THE INSTALLATION OF THE NEW AC PANEL BY THE VENDOR WITH THE VA COR INTO THE NEW TR. THE CONTRACTOR IS TO REMOVE AND RE-USE CARD READERS AND

KEYPADS FROM DECOMMISSIONED TRS FOR NEW CONSTRUCTION TRS WHEREVER POSSIBLE.

I. IT IS THE CONTRACTORS RESPONSIBILITY TO ENSURE ALL ENTRANCE, BACKBONE, AND HORIZONTAL CABLING IS TERMINATED EACH END, TESTED, AND LABELED PER SPECIFICATIONS. FIBER OPTIC CABLING SHALL BE TERMINATED WITHIN RACK MOUNT FIBER ENCLOSURES EACH END. EXACT PART AND MODEL NO WILL NOT BE IDENTIFIED WITHIN RACK ELEVATIONS OR SCHEMATICS. REFER TO SPECIFICATIONS. UTP CABLING SHALL BE TERMINATED EACH END ON SPECIFIED CAT 6A PATCH PANELS WITHIN THE TRS AND

SPECIFIED CAT 6A JACKS AT THE USER OUTLET.

J. CABLE QUANTITIES INDICATED FOR EACH BUILDING ARE APPROXIMATE BASED ON FIELD OBSERVATIONS AND READINESS INFRASTRUCTURE SELF-ASSESSMENTS PROVIDED BY THE VA. SOME LOCATIONS WERE UNABLE TO BE SURVEYED FOR EXISTING COMMUNICATIONS OUTLETS AND CABLING DUE TO PATIENT CARE.

CONTRACTOR SHALL ACCOUNT FOR ADDITIONAL CABLES REQUIRED. CONTRACTOR SHALL ACCOUNT FOR AN ADDITIONAL 20% OF CABLES, DEVICES, AND PATCH PANELS INDICATED ON DRAWINGS IN ORDER TO

ACCOMMODATE THE FULL SCOPE OF THE PROJECT WITHIN BASE BID.

K. EXISTING CEILINGS THROUGHOUT CORRIDORS AND ROOMS WITH EXISTING CABLING MAY NEED TO BE

REMOVED AND REPLACED TO ACCOMMODATE CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR

IDENTIFICATION OF SCOPE OF WORK ASSOCIATED WITH THIS REMOVAL AND INSTALLATION WITHIN BASE BID. WHERE EXISTING CEILINGS ARE LAYIN TILE, GRID SYSTEM MAY REMAIN IN PLACE AND ONLY THE EXISTING TILES WILL REQUIRE REMOVAL AND REPLACEMENT. EXISTING CEILING MOUNTED COMPONENTS SHALL BE TEMPORARILY SUPPORTED AND BE REINSTALLED IN NEW CEILINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR COST OF REPLACEMENT OF CEILING ELEMENTS THAT ARE DAMAGED OR DESTROYED DURING THE PROJECT. REFER TO ARCHITECTURAL DRAWINGS FOR FURTHER INFORMATION. COORDINATE

WITH OWNER FOR PROCUREMENT OF REPLACEMENT CEILING TILES OR OTHER ELEMENTS.

L. REQUIRING THE INSTALLATION OF TEMPORARY FIRESTOPPING (MINERAL WOOL) TO CABLE PENETRATIONS OF RATED WALLS WHERE THE WORK IS NOT COMPLETE AT THE END OF THE WORK SHIFT. REQUIRE CEILING TILES LOCATED OUTSIDE OF CONSTRUCTION AREAS WHICH ARE SEPARATED BY 1-HOUR CONSTRUCTION BARRIERS TO BE REINSTALLED AT THE END OF EVERY WORK SHIFT SINCE MISSING

CEILING TILES CAN RENDER THE SPRINKLER SYSTEM INEFFECTIVE.

M. ALL DECOMMISSIONED TR EQUIPMENT (RACKS, CABLE TRAY, SECURITY CAMERAS, CARD READERS, GROUND BUS BARS, HVAC SPLIT SYSTEMS) SHALL BE MOVED AND INSTALLED INTO NEW CONSTRUCTION

TRS AS NEEDED. EXCESS TR EQUIPMENT IS TO BE RETURNED TO THE VA.

N. ALL EXISTING VOICE CABLES AND WALL FIELD EQUIPMENT ARE TO REMAIN IN SERVICE AS IS.

O. ALL 2 POST RACKS TO BE REPLACED WITH 4 POST RACKS UNLESS OTHERWISE SPECIFIED IN SHEET NOTES.

THE 4 POST RACK IS SPECIFIED IN THE OIT INFRASTRUCTURE STANDARD 3.1 DOCUMENT.

P. THE CONTRACTOR IS RESPONSIBLE FOR MOVING OWNER FURNITURE TO ALLOW FOR EXISTING DATA

DROPS TO BE REPLACED. CONTRACTOR TO COORDINATE WITH THE OWNER FOR DATES AND TIMES THAT

THE FURNITURE CAN BE MOVED.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

TELECOMMUNICATIONS GENERAL NOTES:

1. WORK RESTRICTIONS IN OPERATIONAL ROOMS: WORK WITHIN EXISTING ROOMS (ENTRANCE FACILITY, MAIN COMPUTER ROOMS, TELECOMMUNICATIONS ROOMS) SHALL REQUIRE THE PRESENCE OF A VA ESCORT WHILE THE EXISTING ROOM IS STILL OPERATIONAL AND ACTIVE. WORK WITHIN NEW ROOMS (ENTRANCE FACILITY, MAIN COMPUTER ROOM, TELECOMMUNICATIONS ROOMS) SHALL REQUIRE THE

PRESENCE OF A VA ESCORT ONCE THE NEW ROOM BECOMES OPERATIONAL AND ACTIVE.

2. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR WORK RESTRICTIONS WITHIN EACH BUILDING FOR TIME OF DAY AVAILABILITY OF SPACES AND LEVEL OF INFECTION CONTROL REQUIRED BY

THE CONTRACTOR. CONTRACTOR SHALL ACCOUNT FOR OFF HOURS WORK REQUIRED.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

WORK RESTRICTION NOTES:

PHASING SEQUENCE LISTED BELOW IS FOR INFORMATION ONLY. CONTRACTOR SHALL BE RESPONSIBLE FOR DEVELOPING PROJECT SCHEDULE AND PHASING AND SHALL INCLUDE WORK REQUIRED TO ACCOMMODATE PHASING. SUBMIT PHASING PLAN TO OWNER FOR REVIEW AND APPROVAL AND COORDINATE WITH OWNER

PRIOR TO BEGINNING CONSTRUCTION.

EXISTING ENTRANCE FACILITY ROOM: LOCATED IN BUILDING 04

EXISTING MAIN COMPUTER ROOMS: LOCATED IN BUILDINGS 04

NEW ENTRANCE FACILITY ROOM: LOCATED IN BUILDING 04

A. SITE FIBER TO BUILDINGS: CONSTRUCT REDUNDANT SITE FIBER LOOP FROM MAIN COMPUTER ROOM TO ALL BUILDINGS. MAINTAIN EXISTING FIBER PATHWAYS FROM THE EXISTING MAIN COMPUTER ROOM AS

CURRENTLY CONSTRUCTED FOR THE B SIDE FIBER.

B. NEW TELECOMMUNICATIONS ROOMS AND RESUPPORTED EXISTING TELECOMMUNICATIONS ROOMS:

CONSTRUCT NEW TELECOMMUNICATIONS ROOMS TO BE OPERATIONAL. RESUPPORT EXISTING

TELECOMMUNICATIONS ROOMS TO REMAIN WITH NEW RACKS AND BACKBONE CABLING. PROVIDE NEW A/B

POWER PANELS AND GROUNDING IN NEW AND EXISTING TO REMAIN ROOMS. POWER ALL

TELECOMMUNICATIONS ROOM LOADS FROM THE NEW PANELS. ROUTE NEW PRIMARY AND REDUNDANT FIBER TO NEW TELECOMMUNICATIONS ROOMS AND EXISTING TO REMAIN TELECOMMUNICATIONS ROOMS, FROM THE MAIN COMPUTER ROOM. UPON ACTIVATION OF THESE NEW AND RESUPPORTED ROOMS, BOTH THE NEW AND EXISTING DISTRIBUTION NETWORKS WILL BE SIMULTANEOUSLY ACTIVE TO ALLOW FOR RE- CABLING THE PROGRESSIVE TRANSITION FROM THE EXISTING NETWORK TO THE NEW NETWORK FOR

EACH AREA OUTLET INDIVIDUALLY.

C. EXISTING TELECOMMUNICATIONS ROOMS: MAINTAIN THE EXISTING TELECOMMUNICATIONS ROOMS AND

EXISTING BACKBONE CABLING UNTIL THE AREA OUTLETS BEING SERVED BY EACH RESPECTIVE

TELECOMMUNICATIONS ROOM HAS BEEN TRANSITIONED TO THE NEW TELECOMMUNICATIONS ROOM.

D. RE-CABLING: FOR NEW TELECOMMUNICATIONS ROOMS, PROVIDE NEW CABLES FROM THE EXISTING AREA OUTLETS TO THE NEW RACKS. REMOVE EXISTING CATEGORY 5E OR LOWER CABLING AFTER NEW CABLES HAVE BEEN PULLED TO THE OUTLETS TO MAINTAIN OPERATIONAL CAPABILITY OF THE SPACES TO THE

GREATEST EXTENT POSSIBLE.

E. EXISTING CABLE REMOVAL: AFTER NEW CABLING HAS BEEN INSTALLED AND ACTIVATED, REMOVE EXISTING BACKBONE CABLING AND EXISTING AREA OUTLET CABLING FROM TELECOMMUNICATIONS ROOMS BEING ABANDONED. REMOVE UNUSED CABLING IN PREVIOUSLY ABANDONED TELECOMMUNICATIONS ROOMS.

F. INTERBUILDING BACKBONE: REPLACE THE EXISTING INTERBUILDING BACKBONE CABLING WITH NEW

BACKBONE CABLING. REUSE THE EXISTING BACKBONE PATHWAYS FOR NEW BACKBONE CABLE

INSTALLATION. SIDE A FIBER ROUTE SHALL UTILIZE EXISTING PATHWAYS. EXISTING FIBER UTILIZING EXISTING PATHWAYS SHALL NOT BE REMOVED UNTIL NEW FIBER ROUTE B IS COMPLETE AND NEW

TELECOMMUNICATIONS ROOMS ARE ONLINE AND FUNCTIONING.

G. EXISTING TELECOMMUNICATIONS PROVIDER: REMOVE THE TELECOMMUNICATIONS PROVIDER CABLING TO THE EXISTING ENTRANCE FACILITY ROOM AND SUBSEQUENT EXISTING BACKBONE CABLING FROM THERE TO THE EXISTING MAIN COMPUTER ROOMS. COORDINATE WITH THE VA AND REMOVE/RELOCATE ANY REMAINING ITEMS FROM THE EXISTING MAIN COMPUTER ROOM. DEMOLISH THE EXISTING MAIN COMPUTER

ROOM.

H. SERVER MIGRATION: WITH BOTH THE EXISTING AND NEW DISTRIBUTION NETWORKS BEING

SIMULTANEOUSLY ACTIVE THROUGHOUT THE PROGRESSION OF RE-CABLINGS AND OUTLET TRANSITIONS, MIGRATION OF SERVERS FROM THE EXISTING SERVER ROOM TO THE NEW MAIN COMPUTER ROOM SHALL OCCUR BETWEEN THE TIME THAT THE NEW NETWORK IS ACTIVE (AND READY TO ACCEPT NEW CABLES), BUT BEFORE THE OLD NETWORK IS DEACTIVATED AND REMOVED. AT ALL TIMES, TWO (2) CORE SWITCHES NEED TO BE ACTIVE TO MAINTAIN UTILIZATION OF EXISTING SERVER ROOM AND NEW SERVER ROOM TO

ACCOMMODATE PHASING OF SYSTEMS FROM OLD ROOM TO NEW ROOM.

I. NETWORK ELECTRONICS COORDINATION: CONSIDERING THE ABOVE PHASING, COORDINATION WILL BE

REQUIRED BETWEEN THE VA AND CABLING CONTRACTOR IN ORDER TO PROPERLY SEQUENCE THE

ACQUISITION, CONFIGURATION, AND ACTIVATION OF NETWORK ELECTRONICS IN COORDINATION WITH THE ACTIVATION OF EACH NEW NETWORK DISTRIBUTION POINT, ACTIVATION OF EACH RE-CABLED OUTLET, AND

THE SUBSEQUENT DEACTIVATION OF BOTH EXISTING OUTLET CABLES AND EXISTING NETWORK

DISTRIBUTION POINTS.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

OVERALL PHASING NOTES:

1. REFER TO SPECIFICATIONS APPENDIX A-B FOR ADDITIONAL PHASING INFORMATION.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

TECHNOLOGY PHASING NOTES:

REMARKS:

1. CONTRACTOR TO BUILD A TEMPORARY ENCLOSURE AROUND EXISTING RACK EQUIPMENT IN TRS

THAT ARE BEING RENOVATED. THE TEMPORARY ENCLOSURE MUST KEEP DUCT OUT AND HAVE A

LOCK. THE KEY MUST BE PROVIDED TO THE VA COR.

2. PATCH PANELS SHALL BE CONTRACTOR FURNISHED AND CONTRACTOR INSTALLED PER

SPECIFICATION. REFER TO TYPICAL COMMUNICATION TERMINATION DETAIL.

3. ACCESS CONTROL SYSTEM IS AN EXTENSION OF AN EXISTING ISTAR EX SYSTEM. NEW DEVICES SHALL

FUNCTION AS AN EXTENSION OF THE EXISTING SYSTEM.

4. FIRE ALARM SYSTEM IS AN EXTENSION OF AN EXISTING SIMPLEX SYSTEM. NEW DEVICES SHALL

FUNCTION AS AN EXTENSION OF THE EXISTING SYSTEM.

5. CONTRACTOR TO COORDINATE WITH EXISTING SUPPORT VENDOR, SYNERGY, FOR VIDEO

SURVEILLANCE CAMERAS AS THERE IS AN EXISTING SUPPORT CONTRACT FOR INSTALLATION AND

MAINTENANCE.

6. TELEVISION SYSTEM TO BE RECABLED WHERE EXISTING CABLING IS CATEGORY 5E OR BELOW OR

WHERE EXISTING TELECOMMUNICATIONS ROOM IS BEING ABANDONED. NO NEW TELEVISION

EQUIPMENT IS ANTICIPATED IN THIS CONTRACT.

7. PROVIDE TEMPERATURE AND HUMIDITY MONITORING FOR TELECOMMUNICATIONS ROOM UTILIZING

THE CHATSWORTH 14665-001 USB TEMPERATURE AND HUMIDITY SENSOR (OR EQUIVALENT).

8. WIRELESS ACCESS POINTS TO BE RECABLED WHERE EXISTING CABLING IS CATEGORY 6 OR BELOW

OR WHERE EXISTING TELECOMMUNICATIONS ROOM IS BEING ABANDONED. NO NEW WIRELESS

ACCESS POINTS ARE ANTICIPATED IN THIS CONTRACT.

9. CONTACT GARY AVANTS (SENIOR PHYSICAL SECURITY SPECIALIST) WITH THE VA WITH QUESTIONS.

TR CUTOVER

1. CONTRACTOR CREATES TR / WAO CUTOVER PLAN.

2. CONTRACTOR COMPLETES TR CONSTRUCTION.

3. VA INSPECTS TR PER TR INSPECTION CHECKLIST.

4. CONTRACTOR COMPLETES SITE FIBER BACKBONE.

5. CONTRACTOR COMPLETES MCR CONSTRUCTION IN WHOLE OR PARTIAL (MCR PHASING IF

APPLICABLE).

6. VA INSTALLS MDA CORE NETWORK SWITCHES, CONNECTS POWER TO PDU, CONNECTS FIBER TO LIU.

7. VA INSTALLS TR EDGE SWITCHES, CONNECTS POWER TO PDU, CONNECTS FIBER TO LIU.

8. CONTRACTOR GROUNDS DEVICES TO RACK BUS BAR.

9. VA TRANSITIONS EQUIPMENT IN OLD TR TO EDGE SWITCHES OR NEW FIBER BACKBONE IN NEW TR.

10. VA AND CONTRACTOR CUTOVER WAO FROM OLD TR TO NEW TR PER WAO CUTOVER PLAN.

11. VA MOVES EMPTY EDGE SWITCHES FROM OLD TR TO NEXT TR.

WAO CUTOVER

1. VA NOTIFIES END USERS AND SERVICE LINES OF WAO CUTOVER (30, 15, 7, DAY OF) PER CUTOVER

PLAN.

2. CONTRACTOR IDENTIFIES PATHWAYS FROM HALLWAY TO ROOM FOR RE-USE OR INSTALLS NEW.

3. CONTRACTOR INSTALLS UTP CABLE FROM TR TO PROXIMITY OF WAO.

4. CONTRACTOR INSTALLS NEW WAO, LOCATES EXISTING AND MOVES FURNITURE IF NEEDED.

5. VA DISCONNECTS EQUIPMENT FROM OLD WAO.

6. CONTRACTOR REMOVES OLD UTP CABLE FROM WAO.

7. CONTRACTOR INSTALLS NEW UTP CABLE, TERMINATES AND TESTS.

8. CONTRACTOR LABELS UTP, PATCH PANEL AND WAO.

9. VA CONNECTS PATCH CABLES FROM PATCH PANEL TO EDGE SWITCH.

10. VA VALIDATES PROPER CONNECTIVITY, POE AND VLAN ASSIGNMENT AT WAO.

11. VA CONNECTS EQUIPMENT TO WAO.

12. CONTRACTOR MOVES FURNITURE BACK TO ORIGINAL LOCATION.

13. CONTRACTOR REMOVES ALL OLD UTP, WALL MOUNTED 110 BLOCKS, PATCH PANELS, RACK IF EMPTY.

GENERAL NOTES:

A. REFER TO SYMBOL LEGENDS AND SPECIFICATIONS FOR SPECIFIC REQUIREMENTS.

B. COORDINATE ROUGH-IN REQUIREMENTS WITH FINAL EQUIPMENT SELECTION FOR ALL SYSTEMS.

C. COORDINATE ROUGH-IN REQUIREMENTS WITH OWNER FOR OWNER FURNISHED SYSTEMS.

D. CONDUITS SHALL ROUTE CONCEALED INSIDE WALL TO ABOVE NEAREST ACCESSIBLE CEILING SPACE, UNLESS OTHERWISE INDICATED.

E. WHERE CABLING IS CONTRACTOR FURNISHED AND CONTRACTOR INSTALLED, TERMINATE AND TEST

ALL CABLING PER SPECIFICATION.

A. THE INTENT OF THE DEMOLITION DRAWINGS IS TO DEFINE THE SCOPE OF ELECTRICAL DEMOLITION

WORK. PROVIDE DEMOLITION FOR ITEMS AS SHOWN.

B. ITEMS INDICATED WITH A SUBSCRIPT 'E' SHALL BE EXISTING TO REMAIN (E-EXISTING). ITEMS INDICATED WITH A SUBSCRIPT 'D' OR SHOWN DASHED SHALL BE REMOVED (D-DEMOLITION). ITEMS INDICATED WITH A SUBSCRIPT 'R' SHALL BE REMOVED, STORED, AND REINSTALLED PER NEW WORK (R-RELOCATION).

C. THESE DRAWINGS DO NOT IDENTIFY EACH INDIVIDUAL ITEM TO BE REMOVED. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING ITEMS WHICH MUST BE REMOVED TO FACILITATE NEW CONSTRUCTION.

SEE ARCHITECTURAL PLANS FOR EXACT LIMITS OF DEMOLITION AND CONSTRUCTION. THESE PLANS ARE BASED ON PAST PROJECT DRAWINGS AND SITE OBSERVATIONS. THE DRAWINGS ARE PROVIDED TO THE CONTRACTOR AS AN AID IN DETERMINING THE EXTENT OF WORK REQUIRED FOR DEMOLITION AND TO PROVIDE GENERAL INFORMATION ABOUT EXISTING SYSTEMS. THESE DRAWINGS MAY NOT BE ACCURATE IN ALL AREAS. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS AND IS ENCOURAGED TO REVIEW FACILITY DRAWINGS PRIOR TO THE BID SUBMITTAL.

D. THE OWNER SHALL HAVE FIRST SALVAGE RIGHTS TO ALL ITEMS REMOVED. IF OWNER REFUSES

SALVAGE, CONTRACTOR IS RESPONSIBLE FOR THE LEGAL AND RESPONSIBLE DISPOSAL.

E. WHERE EXISTING WALLS ARE TO BE REMOVED, ALL ASSOCIATED TELECOMMUNICATIONS EQUIPMENT

SHALL BE REMOVED. SEE ARCHITECTURAL DRAWINGS FOR WALLS TO BE REMOVED. ABANDON

CONCEALED CONDUITS WHERE WALLS ARE NOT REMOVED. CONCEALED CONDUITS MAY BE REUSED

WHERE AVAILABLE. WHERE EXISTING CABLING IS TO BE DEMOLISHED AND NOT REUSED, REMOVE CABLES AND ASSOCIATED ACCESSIBLE RACEWAYS/CONDUIT BACK TO THE SOURCE. WHERE EXISTING CONDUITS TO BE DEMOLISHED ARE EMBEDDED IN CONCRETE FLOORS OR WALLS, CONDUITS MAY BE ABANDONED IN PLACE. EXISTING CABLES SHALL BE REMOVED BACK TO SOURCE AND CONDUITS SHALL BE CUT AT SURFACE OF CONCRETE AND FILLED. EXISTING BACK BOXES AND CONDUITS REMAINING FROM DEVICES BEING REMOVED MAY BE UTILIZED FOR NEW DEVICES WHERE LOCATIONS PERMIT. REMOVE

AND PATCH WHERE BOXES ARE NOT REUSED.

F. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL ELECTRICAL DEMOLITION ITEMS. DISCONNECT AND REMOVE ELECTRICAL DEVICES, EQUIPMENT AND ASSOCIATED WIRING AS REQUIRED TO ACCOMMODATE NEW WORK. IF THE CONTRACTOR IS UNCLEAR REGARDING A SPECIFIC ITEM TO REMAIN OR BE REMOVED, THE CONTRACTOR SHALL SEEK CLARIFICATION FROM THE ARCHITECT.

G. SYSTEMS SERVING ADJACENT AREAS AND ITEMS THAT REMAIN SHALL BE MAINTAINED AT ALL TIMES.

MODIFY SYSTEMS AS REQUIRED THROUGHOUT CONSTRUCTION TO MAINTAIN CONTINUITY OF SERVICE.

DO NOT INTERRUPT SERVICE WITHOUT OWNER'S PRIOR WRITTEN APPROVAL. LIMIT DURATION OF INTERRUPTION ONLY TO THE TIME NECESSARY FOR DISCONNECTION AND IMMEDIATE RECONNECTION.

INTERRUPTION TO SERVICE DEEMED BY OWNER AS ESSENTIAL MAY REQUIRE PREMIUM TIME AND SHALL BE INCLUDED WITH THE BID. EXTREME CARE SHALL BE TAKEN BY THE CONTRACTOR TO IDENTIFY EXISTING SYSTEM COMPONENTS ASSOCIATED WITH THESE SERVICES. APPROPRIATE METHODS OF MARKING THESE SHALL OCCUR TO ELIMINATE THE POSSIBILITY OF ACCIDENTAL INTERRUPTION. FOR CONDUIT AND CABLING THAT CAN REMAIN, PROVIDE SUPPORT AS REQUIRED. RELOCATE EXISTING

JUNCTION BOXES THAT BECOME INACCESSIBLE DUE TO NEW WORK.

H. COORDINATE DEMOLITION WITH THE WORK OF OTHER TRADES. PROVIDE TEMPORARY SERVICES AS

REQUIRED TO ALLOW THE WORK OF OTHER TRADES TO PROCEED.

I. PROTECT EXISTING TELECOMMUNICATIONS EQUIPMENT THAT REMAINS. IF DAMAGED OR DISTURBED IN THE COURSE OF THE WORK, REMOVE DAMAGED PORTIONS AND INSTALL NEW PRODUCTS OF EQUAL

CAPACITY, QUALITY, AND FUNCTIONALITY.

J. PATCH AND REPAIR OPENINGS IN EXISTING WALLS AND FLOORS RESULTANT FROM SPECIFIED ELECTRICAL DEMOLITION. PATCH SHALL MATCH EXISTING CONSTRUCTION, FIRE RATING, AND FINISH.

SEE ARCHITECTURAL SPECIFICATIONS FOR MEANS AND METHODS.

K. THIS PROJECT WILL BE PHASED. SEE PROJECT MANUAL AND ARCHITECTURAL PLANS FOR DETAILS.

SYSTEM SERVICES TO AREAS NOT IN THE CURRENT PHASE OF CONSTRUCTION SHALL BE MAINTAINED AT

ALL TIMES.

L. WHERE DEMOLITION OF EQUIPMENT INVOLVES REMOVAL OF EQUIPMENT LOCATED ON CONCRETE HOUSEKEEPING PADS, PADS SHALL ALSO BE REMOVED AND FLOOR/GRADE SHALL BE FINISHED TO MATCH

ADJACENT SURFACE.

M. ALL UNLABELED TELECOMMUNICATIONS DEVICES SHALL BE TRACED AS NEEDED WITH A LABEL

PROVIDED.

N. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT OF ALL CABLING, PATHWAYS, AND SYSTEMS

LOCATED ABOVE CEILING THAT ARE REQUIRED TO BE MODIFIED AS A PART OF THE PROJECT.

CONTRACTOR SHALL REPLACE ANY ITEMS DAMAGED FROM TEMPORARY SUPPORT.

O. EXISTING ANALOG DEVICES ACTIVELY SERVING EQUIPMENT SHALL BE EXISTING TO REMAIN REGARDLESS IF SHOWN AS BEING REMOVED. CONNECTIONS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING. THE

CONTRACTOR SHALL FIELD VERIFY DURING CONSTRUCTION.

a. FAX, ELEVATORS, PATIENT TELEPHONES, BLUE PHONES, CODE BLUE DEVICES, FIRE ALARM, MEDICAL

ANALOG EQUIPMENT, PANIC DURESS, ETC.

P. WITHIN EXISTING SPACES THAT ARE TO BE DEMOLISHED TO BE CONVERTED INTO A TR OR MCR, REROUTE

ANY EXISTING LOW VOLTAGE CABLING OUTSIDE THE ROOM. SPLICE AND EXTEND CONDUCTORS AS

REQUIRED. REPLACE ANY CATEGORY CABLES NEEDING TO BE REROUTED.

Q. ALL CATEGORY 5E AND LOWER DATA CABLES THAT ARE REMOVED FROM THE RACK ARE TO BE REMOVED ENTIRELY TO THE WORK AREA. THE WORK AREA WALL PLATES AND JACKS ARE ALSO PART OF THE DEMOLITION. OLD DATA CABLES CANNOT BE DEMOLISHED UNTIL NEW CAT6A CABLES HAVE BEEN INSTALLED AND THE CLIENT IS ACTIVELY USING THE NEW DATA DROP. SEE THE SEQUENCING NOTES FOR

ADDITIONAL DETAIL.

R. FIBER CABLES THAT ARE IN TRS TO BE DEMOLISHED ARE TO BE REMOVED ENTIRELY BACK TO THE SERVER ROOM. ANY CONDUIT USED BY THE EXISTING FIBER WILL REMAIN AND POTENTIALLY BE USED BY NEW FIBER PULLS. FIBER IN TRS THAT WILL NOT RELOCATE IS TO REMAIN AS EXISTING. B SIDE FIBER TO NEW TR LOCATIONS MAY REUSE PREVIOUS FIBER PATHS TO THE NEW TR ROOM. ADDITIONAL CONDUIT

MAY BE NEEDED TO GET THE FIBER TO THE NEW TR.

S. CONTRACTOR TO BUILD ENCLOSURES AROUND TR CABINETS WHERE NEEDED TO PROVIDE SEPARATION FROM CONSTRUCTION ACTIVITIES. ENCLOSURE MUST PROVIDE POSITIVE FILTERED AIR PRESSURE AND

LOCKABLE SECURITY DOOR AND HASP.

T. ALL CONTRACTOR AND SUBCONTRACTOR STAFF TO OBTAIN AND MAINTAIN TIER 1 NON-LOGICAL PIV

BADGE VIA US ACCESS FOR THE DURATION OF THE PROJECT.

U. ENTRY INTO EXISTING AND NEW TRS WITH NETWORK SWITCHES INSTALLED WILL REQUIRE VA OIT

ESCORTS.

V. OIT MAY GRANT TR ENTRY ESCORT STATUS TO SELECT CONTRACTOR STAFF THAT WITH TIER 1 OR TIER 2

BADGES.

(TELECOMMUNICATION DEMOLITION GENERAL NOTES APPLY TO ALL TELECOMMUNICATION DEMOLITION PLANS

AND ALL TELECOMMUNICATION DEMOLITION WORK)

TELECOMMUNICATION DEMO GENERAL NOTES:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL BID

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 22328

A u to d e s k D o c s /2

N a s h v ill e E

H R

M /6

-7

.B

.E

T

R

.r v t

/1

/2

:4

:3

P

M

T000

TELECOMMUNICATIONS SYMBOLS AND

ABBREVIATIONS

EHRM INFRASTRUCTURE

UPGRADES DESIGN

1310 24TH Avenue South Nashville, TN 37212

626-22-700

02/16/2024 NMT SSK

DATA SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

COMMUNICATIONS OUTLET -

CEILING

PROVIDE CATEGORY 6A NETWORK DATA CABLES FROM ASSOCIATED TELECOMMUNICATION ROOM TO APPROXIMATE LOCATION INDICATED ON FLOOR PLANS. QUANTITY OF CABLES PER DEVICE INDICATED ON FLOOR PLANS. TERMINATE CABLE WITH RJ45 CONNECTOR IN FACEPLATE, CENTERED IN CEILING TILE. PROVIDE WITH 15' OF CABLE SLACK AT LOCATION INDICATED. PROVIDE ROUGH-IN PER COMMUNICATIONS OUTLET DETAIL AT LOCATIONS INDICATED WITHIN GYP CEILINGS. PROVIDE SURFACE MOUNTED CONDUIT AND BACK BOX IN UNFINISHED AREAS. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND

WITHIN CONDUIT IN UNFINISHED AREAS.

COMMUNICATIONS OUTLET -

WALL

GENERAL:

PROVIDE COMMUNICATIONS OUTLET AS DESCRIBED IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH OUTLET TYPE. REFER TO PLANS FOR OUTLET DESIGNATION AND QUANTITIES OF NETWORK VOICE/DATA CABLES TO BE PROVIDED TO OUTLET FROM ASSOCIATED NEAREST TELECOMMUNICATION ROOM. EXISTING CONDITIONS FOR THE WORK AREA OUTLETS ARE SHOWN ON THE PLANS IN THE FORMAT #D#V#P. SEE THE LEGEND BELOW FOR DESCRIPTION. FOR NEW OUTLET LOCATIONS, PROVIDE ROUGH-IN PER COMMUNICATIONS OUTLET DETAIL. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTION 271200 INCLUDING, BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, JACKS, INSERTS, FACEPLATES, AND CABLING. SUBMIT SHOP DRAWINGS FOR APPROVAL. COORDINATE EXACT FINAL LOCATION WITH ARCHITECTURAL INTERIOR ELEVATIONS PRIOR TO INSTALLATION. PROVIDE CABLING AS LISTED BELOW. OUTLETS WITH NO CABLING DESIGNATION SHALL BE EMPTY WITH A BLANK WALL PLATE. CABLING DESIGNATIONS ARE TYPICAL FOR ALL WALL, FLOOR, AND CEILING COMMUNICATIONS DEVICES. REFER TO SPECIFICATIONS FOR CABLING REQUIREMENTS FOR EACH TYPE.

D = ACTIVE DATA OUTLETS

V = ACTIVE VOICE OUTLETS

P = TOTAL NUMBER OF OUTLETS (WIRES WITH JACKS)

TYPE ‘W’, WALL PHONE:

PROVIDE ONE (1) NETWORK DATA CABLE, MOUNTED IN WALL PHONE MOUNTING BRACKET FACEPLATE, MOUNTED AT 48” AFF. COORDINATE MOUNTING LOCATION WITH OTHER TRADES AND FINAL EQUIPMENT SELECTION.

FLOOR BOX - VOICE/DATA GENERAL:

CONTRACTOR TO USE EXISTING FLOOR BOX ENCLOSURES. REFER TO PLANS FOR FLOOR BOX DESIGNATION, AND QUANTITIES OF NETWORK VOICE/DATA CABLES TO BE PROVIDED TO FLOOR BOX FROM ASSOCIATED COMMUNICATIONS DISTRIBUTION ROOM. PROVIDE NETWORK VOICE/DATA CABLES, JACKS, INSERTS, AND FACEPLATES WITHIN FLOOR BOX PER SPECIFICATION SECTION 271200. COORDINATE REQUIREMENTS WITH FLOOR BOX MANUFACTURER. PROVIDE ALL ACCESSORIES FOR A COMPLETE INSTALLATION, INCLUDING BUT NOT LIMITED TO: BRACKETS, A/V PLATES, BLANK COVER ASSEMBLIES, MOUNTING FRAMES, ADAPTERS, AND CONCRETE FLOOR ACCESSORIES/OPTIONS. COORDINATE EXACT FINAL LOCATION WITH ARCHITECT, OWNER, OWNER'S FINAL FURNITURE SELECTIONS AND LOCATIONS, AND FINAL FLOOR FINISH SELECTIONS PRIOR TO INSTALLATION.

COORDINATE FLOOR BOX DEPTH WITH FINAL CONCRETE FLOOR DEPTH. SAW CUT FLOOR AS REQUIRED TO ACCOMMODATE FLUSH INSTALLATION AND CONCEALMENT OF CONDUITS. CONCEAL ALL CONDUITS IN FLOOR AND IN ADJACENT WALL. SUBMIT PRODUCT DATA FOR APPROVAL. COORDINATE INSTALLATION WITH OWNER.

TYPE 'FB1', ON/BELOW GRADE CAST-IRON VOICE/DATA FLOOR BOX:

PROVIDE WIREMOLD OMNIBOX SERIES MODEL 880CS1-1 FLOOR BOX WITH RECTANGULAR FLIP LID COVER PLATE (OR PRIOR APPROVED EQUIVALENT). PROVIDE COVER AND FLANGE WITH BRUSHED ALUMINUM FINISH. PROVIDE ONE (1) 1" CONDUIT TO NEAREST CORRIDOR CABLE TRAY FOR NETWORK VOICE/DATA CONNECTIONS.

WIRELESS ACCESS POINT -

CEILING

OWNER PROVIDED WIRELESS ACCESS POINT AT APPROXIMATE LOCATION INDICATED. PROVIDE TWO (2) CATEGORY 6A NETWORK DATA CABLES FROM TELECOMMUNICATION ROOM TO APPROXIMATE LOCATION INDICATED ON FLOOR PLANS, COILED ABOVE FINISHED CEILING. TERMINATE CABLE WITH RJ45 CONNECTOR.

PROVIDE WITH 15' OF CABLE SLACK AT LOCATION INDICATED. PROVIDE ROUGH-IN PER COMMUNICATIONS OUTLET DETAIL AT LOCATIONS INDICATED WITHIN GYP CEILINGS. PROVIDE SURFACE MOUNTED CONDUIT AND BACK BOX IN UNFINISHED AREAS. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS. LOCATIONS SHOWN ARE PRELIMINARY. CONFIRM FINAL LOCATION WITH

OWNER PRIOR TO PULLING CABLE.

COMMUNICATION SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

4 POST COMMUNICATIONS RACK GENERAL:

PROVIDE DATA EQUIPMENT IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH TYPE DATA EQUIPMENT.

COORDINATE EXACT FINAL LOCATION WITH OWNER'S IT REPRESENTATIVE PRIOR TO INSTALLATION. PROVIDE ALL POWER CONNECTIONS INDICATED ON FLOOR PLANS AT FINAL CABINET LOCATION. REFER TO SPECIFICATIONS FOR

ADDITIONAL REQUIREMENTS.

TYPE '4-POST', 4-POST DATA RACK:

PROVIDE 7'-0" TALL 45U, TELECOMMUNICATIONS CABINET AT APPROXIMATE LOCATIONS INDICATED ON FLOOR PLANS. REFER TO FLOOR PLANS FOR DATA SWITCH ELECTRICAL SOURCE AND REQUIREMENTS. PROVIDE TELECOMMUNICATIONS CABINET AND ALL ACCESSORIES PER SPECIFICATION SECTION 271100. PROVIDE ALL ACCESSORIES FOR A COMPLETE INSTALLATION, INCLUDING BUT NOT LIMITED TO: BRACKETS, MOUNTING FRAMES, HORIZONTAL AND VERTICAL INTEGRATED WIRE MANAGEMENT, LASHING MANAGER, RADIUS DROPS, PDU

BRACKETS, AND GROUNDING CONNECTIONS.

TYPE 'SERVER', SERVER CABINET WITH VERTICAL EXHAUST DUCT:

PROVIDE TERAFRAME F-SERIES GEN 3 CABINET FF1N-111C-E52-B (OR PRIOR APPROVED EQUIVALENT). PROVIDE

WITH ALL ACCESSORIES AS DEFINED IN OIT STANDARDS.

TYPE: 'NETWORK', NETWORK CABINET WITH VERTICAL EXHAUST DUCT:

PROVIDE CHATSWORTH NF8N-115N-E52-1 (OR PRIOR APPROVED EQUIVALENT). PROVIDE WITH SIDE PANELS WITH BRUSH SEALED CABLE OPENINGS CHATSWORTH 39043-E63 (OR PRIOR APPROVED EQUIVALENT) ORDERED SEPERATELY FROM CABINET. PROVIDE WITH ALL ACCESSORIES AS DEFINED IN OIT STANDARDS.

COMMUNICATIONS FIRE RATED

PATHWAY - FLOOR

PROVIDE STI FIRESTOP EZ-PATH COMMUNICATIONS FIRE RATED PATHWAY THROUGH FLOOR AT LOCATIONS INDICATED ON FLOORPLANS. COORDINATE MOUNTING LOCATION WITH STRUCTURE, EQUIPMENT WITHIN ROOM, ACCESS TO EQUIPMENT, WALLS BELOW ROOM, AND OTHER TRADES. INSTALL PER MANUFACTURERS RECOMMENDATIONS. REFER TO FLOOR PLANS FOR PATHWAY TYPE AND QUANTITIES. PROVIDE PATHWAY TYPES AS

INDICATED BELOW.

(F1) - FULL KIT CATALOG # EZDP144FKS2 (1-4"x4" PATHWAY) (F2) - FULL KIT CATALOG # EZDG444S2 (4-4"x4" PATHWAYS) (F3) - FLOOR GRID CATALOG # EZG844 AND ONE (1) PATHWAY MODULE CATALOG # EZD444MBS2 (4-4"x4" PATHWAYS & 4-4"x4" SPACES) (F4) - FULL KIT CATALOG # EZDG844S2 (8-4"x4" PATHWAYS)

COMMUNICATIONS FIRE RATED

PATHWAY – WALL

PROVIDE STI FIRESTOP EZ-PATH COMMUNICATIONS FIRE RATED PATHWAY AT LOCATIONS INDICATED ON FLOORPLANS. MOUNT PATHWAYS ABOVE ACCESSIBLE CEILING SPACES. COORDINATE MOUNTING HEIGHT WITH CABLE TRAY, TELECOMMUNICATION RACK HEIGHTS, CEILING, AND OTHER TRADES. INSTALL PER MANUFACTURERS RECOMMENDATIONS. COORDINATE REQUIRED WALL OPENING WITH STUD SPACING. REFER TO FLOOR PLANS FOR

PATHWAY TYPE AND QUANTITIES. PROVIDE PATHWAY TYPES AS INDICATED BELOW.

(A1) - FULL KIT CATALOG # EZDP133CWK (1-3"x3" PATHWAY) (A2) - FULL KIT CATALOG # EZDP233GK (2-3"x3" PATHWAYS) (A3) - FULL KIT CATALOG # EZDP333GK (3-3"x3" PATHWAYS) (A4) - FULL KIT CATALOG # EZDP433GK (4-3"x3" PATHWAYS) (A7) - FULL KIT CATALOG # EZDP733GK (7-3"x3" PATHWAYS) (A8) - TWO (2) FULL KIT CATALOG # EZDP433GK (8-3"x3" PATHWAYS) (STACKED) (B1) - FULL KIT CATALOG # EZD22 (1-2"x2" PATHWAY) (C1) - FULL KIT CATALOG # EZDP44S2 (1-4"x4" PATHWAY) (C2) - TWO (2) MODULE CATALOG # EZD44S2 & ONE (1) EZP544W (2-4"x4" PATHWAYS) (C3) - THREE (3) CATALOG # EZD44S2 & ONE (1) EZP544W (3-4"x4" PATHWAYS) (C4) - FOUR (4) CATALOG # EZD44S2 & ONE (1) EZP544W (4-4"x4" PATHWAYS) (REQUIRES 16" STUD SPACING) (C5) - FIVE (5) CATALOG # EZD44S2 & ONE (1) EZP544W (5-4"x4" PATHWAYS) (REQUIRES 24" STUD SPACING)

PROVIDE STI FIRESTOP EZ-PATH CABLE SPILLWAY AT LOCATIONS INDICATED ON FLOORPLANS WITH SUBSCRIPT 'S'.

PROVIDE ONE (1) SPILLWAY PER SLEEVE. REFER TO FLOORPLANS FOR SPILLWAY TYPE AND QUANTITIES.

(A#S) - CATALOG NO. RCM33

(C#S) - CATALOG NO. EZRCM44S

PROVIDE STI FIRESTOP EZ-PATH EXTENSION MODULES AT LOCATIONS INDICATED ON PLANS WITH SUBSCRIPT 'E'.

PROVIDE ONE (1) EXTENSION MODULE PER SLEEVE. WHERE PATHWAY IS INDICATED WITH SUBSCRIPT 'EE', PROVIDE ONE (1) EXTENSION MODULES ON EACH END. REFER TO FLOORPLANS FOR EXTENSION MODULE TYPE AND

QUANTITIES.

(A#E) - CATALOG NO. EZD33E

(C#E) - CATALOG NO. EZD44ES

PLYWOOD BACKBOARD PROVIDE 3/4" THICK X 4' WIDE X 8' HIGH A/C GRADE FIRE-RETARDANT TREATED PLYWOOD BACKBOARD AT APPROXIMATE LOCATION INDICATED. REFER TO FLOORPLANS FOR WIDTHS. CUT ADDITIONAL PLYWOOD TO FIT APPROXIMATE WIDTH INDICATED ON FLOORPLANS. MOUNT PLYWOOD VERTICALLY. BUTT ADJACENT SHEETS TIGHTLY, AND FORM SMOOTH GAP-FREE CORNERS AND JOINTS. PROVIDE WITH TWO (2) COATS OF WHITE PAINT ON ALL FACES AND EDGES. PROVIDE WITH LABEL ON EACH SHEET OF PLYWOOD WITH FIRE RATINGS, VISIBLE

AFTER PAINTING. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

TELECOMMUNICATIONS

GROUND BAR

PROVIDE LENGTH AS REQUIRED TO ACCOMMODATE TERMINATIONS, MINIMUM 10" IN LENGTH. REFER TO

SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

WALL MOUNT TELECOM

ENCLOSURE

PROVIDE 48" H (26U) WALL MOUNT CABINET AT APPROXIMATE LOCATIONS INDICATED ON FLOOR PLANS. PROVIDE CUBE-ITWALL MOUNT CABINET GEN 3. PROVIDE APC AP9560 OR EQUIVALENT RACK MOUNT PDU; L5-30 PLUG; (10) NEMA 5-20 OUTLETS; 1RU; TWO PER ENCLOUSURE; ONE ENERGIZED BY UPS; ONE ENERGIZED BY WALL OUTLET.

PROVIDE TELECOMMUNICATIONS RACK AND ALL ACCESSORIES PER SPECIFICATION SECTION 271200 AND DETAILS SHEETS. COORDINATE EXACT FINAL LOCATION WITH OWNER'S IT REPRESENTATIVE PRIOR TO INSTALLATION.

PROVIDE ALL POWER CONNECTIONS INDICATED ON FLOOR PLANS AT FINAL RACK LOCATION. REFER TO

SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

SECURITY SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

ACCESS CONTROL DEVICE GENERAL:

PROVIDE ACCESS CONTROL COMPONENTS AS DESCRIBED IN THESE GENERAL NOTES. REFER TO FLOOR PLANS FOR DEVICE DESIGNATION. PROVIDE ROUGH-INS PER ACCESS CONTROL ROUGH-IN DETAIL. DOOR ACCESS COMPONENTS SHALL BE RATED FOR CONTINUOUS OPERATION IN THEIR INSTALLED PROJECT CONDITIONS AS REQUIRED IN SPECIFICATION SECTION 281300. COORDINATE REQUIRED CONDUITS TO DOOR FRAME AND WALL MOUNTED DEVICES WITH DOOR HARDWARE CONTRACTOR. PROVIDE SURFACE MOUNTED CONDUIT AND BACK BOX IN UNFINISHED AREAS. PROVIDE 20A 120V NORMAL EQUIPMENT BRANCH CIRCUIT TO DOOR CONTROLLERS LOCATED WITHIN ACCESS CONTROL CABINET IN ASSOCIATED COMMUNICATIONS LOW VOLTAGE ELECTRICAL ROOM ABOVE EACH ACCESS CONTROLLED DOOR. PROVIDE FINAL CONNECTION OF 120V BRANCH CIRCUIT TO ALL POWER SUPPLIES REQUIRED FOR EACH DOOR FUNCTION. REFER TO FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATIONS.

PROVIDE ACCESS CONTROL CABLING FROM DOOR CONTROLLER TO COMPONENTS REQUIRED BY THE DOOR HARDWARE SPECIFICATION INCLUDING BUT NOT LIMITED TO CARD READER, DOOR POSITION SWITCH, ELECTRIC STRIKE, ELECTRIFIED HINGE, DOOR RELEASE PUSH BUTTON, MAGNETIC LOCK, AND REQUEST TO EXIT. PROVIDE DOOR POSITION SWITCH AND REQUEST TO EXIT AT EACH ACCESS CONTROLLED DOOR, UNLESS PROVIDED BY DOOR HARDWARE CONTRACTOR. CONTRACTOR SHALL TERMINATE ACCESS CONTROL CABLING TO DEVICES AT DOOR LOCATION AND PROVIDE A 7'-0" PIGTAIL WITHIN COMMUNICATIONS LOW VOLTAGE ELECTRICAL ROOM AT ACCESS CONTROL CABINET WITH APPROPRIATE DEVICE LABEL FOR OWNER TERMINATION. COORDINATE ALL TERMINATION REQUIREMENTS AND EXACT LOCATION OF TERMINATIONS WITH OWNER'S ACCESS CONTROL MANAGER. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTION 281300 INCLUDING BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, AND CABLING. WHERE DOOR IS ALSO SPECIFIED/SHOWN TO UTILIZE DOOR OPERATOR, PROVIDE INTERLOCK TO ALLOW AUTOMATIC DOOR OPENING FROM THE ACCESS CONTROL SYSTEM UPON SUCCESSFUL CARD READ. SUBMIT SHOP DRAWINGS FOR APPROVAL. PROVIDE FIRE ALARM SYSTEM CONNECTION FOR DOOR RELEASE UPON ALARM.

INTEGRATE ACCESS CONTROL SYSTEM WITH DOOR OPERATORS AND DOOR HARDWARE. REFER TO ACCESS CONTROL AND ARCHITECTURAL DOOR HARDWARE SPECIFICATIONS FOR COORDINATION OF FEATURES, DEVICES, AND CONNECTIONS REQUIRED.

ACCESS CONTROL PANEL CIRCUIT CONTROL PANEL TO 20A 120V BRANCH CIRCUIT IN LOCAL CRITICAL BRANCH PANEL OF THE ASSOCIATED CONSTRUCTION PHASE. REFER TO FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATIONS. COORDINATE CONNECTION REQUIREMENTS WITH FINAL EQUIPMENT SELECTION AND PROVIDE NEMA 5-20 RECEPTACLE OR

HARD-WIRED CONNECTION TO CABINET AS REQUIRED.

CREDENTIAL CARD READER GENERAL:

PROVIDE PROXIMITY CARD READER AT APPROXIMATE LOCATION INDICATED. REFER TO FLOOR PLANS FOR CARD READER DESIGNATION. PROVIDE ROUGH-IN PER ACCESS CONTROL ROUGH-IN DETAIL. WHERE SHOWN MOUNTED ON DOOR/WINDOW SYSTEM MULLION, PROVIDE MULLION MOUNT CARD READER SURFACE MOUNTED ON MULLION.

CABLING SHALL BE ROUTED RECESSED WITHIN MULLION TO ACCESSIBLE CEILING SPACE. COORDINATE INSTALLATION WITH MULLION MANUFACTURER. CARD READERS SHALL BE RATED FOR CONTINUOUS OPERATION IN THEIR INSTALLED PROJECT CONDITIONS AS REQUIRED IN SPECIFICATION SECTION 281300. SUBMIT SHOP DRAWINGS FOR APPROVAL. COORDINATE EXACT LOCATION OF CARD READER WITH ARCHITECT, ARCHITECTURAL INTERIOR ELEVATIONS, AND OTHER DOOR COMPONENTS INCLUDING BUT NOT LIMITED TO PUSH PLATE ACTUATORS. REFER TO ACCESS CONTROL SYMBOL LEGEND DESCRIPTION FOR CABLING AND ADDITIONAL

REQUIREMENTS.

TYPE ‘KEYPAD’, COMBINATION KEYPAD PROXIMITY CARD READER:

PROVIDE COMBINATION KEYPAD PROXIMITY CARD READER PER SPECIFICATION.

INTRUSION DETECTION SYSTEM

- CONTROL PANEL

CIRCUIT CONTROL PANEL TO 20A 120V BRANCH CIRCUIT IN LOCAL UPS BRANCH PANEL OF THE ASSOCIATED CONSTRUCTION PHASE. REFER TO FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATIONS. COORDINATE CONNECTION REQUIREMENTS WITH FINAL EQUIPMENT SELECTION AND PROVIDED NEMA 5-20 RECEPTACLE OR HARD-WIRED CONNECTION TO CONTROL PANEL AS REQUIRED. PROVIDE ONE (1) NETWORK DATA CABLE FROM ASSOCIATED COMMUNICATIONS DISTRIBUTION ROOM. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTIONS 280513 AND 281300 INCLUDING BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, ROUGH-INS, AND CABLING. SUBMIT SHOP DRAWINGS FOR APPROVAL. COORDINATE EXACT LOCATION OF KEYPAD WITH ENGINEER, ARCHITECT, AND ARCHITECTURAL

INTERIOR ELEVATIONS.

INTRUSION DETECTION SYSTEM

- KEYPAD

PROVIDE KEYPAD FOR INTRUSION DETECTION SYSTEM AT APPROXIMATE LOCATION INDICATED ON FLOOR PLANS, MOUNTED AT 48" AFF. COORDINATE CABLING AND ROUGH-IN REQUIREMENTS WITH MANUFACTURER.

PROVIDE CABLING TO INTRUSION DETECTION SYSTEM CONTROL PANEL PER MANUFACTURER INSTALLATION REQUIREMENTS. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS. PROVIDE CABLING PER SPECIFICATION SECTION 281600. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTION 281600 INCLUDING BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, ROUGH-INS, AND CABLING. SUBMIT SHOP DRAWINGS

FOR APPROVAL. COORDINATE EXACT LOCATION OF KEYPAD WITH ENGINEER, ARCHITECT, AND

ARCHITECTURAL INTERIOR ELEVATIONS.

INTRUSION DETECTION SYSTEM

- MOTION SENSOR

PROVIDE MOTION SENSOR COVERAGE OF SPACE INDICATED FOR INTRUSION DETECTION SYSTEM. EXACT QUANTITIES AND LOCATIONS OF DEVICES SHALL BE DETERMINED BY MANUFACTURER REQUIREMENTS. MOUNT DEVICES IN ACCESSIBLE LOCATIONS. PROVIDE BACK BOX AND CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING FOR CABLING AT LOCATIONS INDICATED WITHIN GYP CEILINGS OR WHERE EXPOSED WITHIN UNFINISHED AREAS. COORDINATE CABLING AND ROUGH-IN REQUIREMENTS WITH MANUFACTURER. PROVIDE

CABLING TO INTRUSION

DETECTION SYSTEM CONTROL PANEL PER MANUFACTURER INSTALLATION REQUIREMENTS. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS. PROVIDE CABLING PER SPECIFICATION SECTIONS 280513 AND 281300. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTIONS 280513 AND 281300 INCLUDING BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, ROUGH-INS, AND CABLING. SUBMIT SHOP DRAWINGS

FOR APPROVAL.

SECURITY SURVEILLANCE

CAMERA - CEILING

GENERAL:

PROVIDE CABLING FOR OWNER PROVIDED POWER OVER ETHERNET (POE) SECURITY SURVEILLANCE CAMERA AS DESCRIBED AT LOCATIONS INDICATED. REFER TO FLOOR PLANS FOR CAMERA DESIGNATION. SECURITY SURVEILLANCE COMPONENTS SHALL BE RATED FOR CONTINUOUS OPERATION IN THEIR INSTALLED PROJECT CONDITIONS AS REQUIRED IN SPECIFICATION SECTION 282300. PROVIDE ONE (1) CATEGORY 6A NETWORK DATA CABLE FROM ASSOCIATED COMMUNICATIONS DISTRIBUTION ROOM TO APPROXIMATE LOCATION INDICATED ON FLOOR PLANS, COILED ABOVE FINISHED CEILING. TERMINATE CABLE WITH RJ45 CONNECTOR. PROVIDE WITH 10' OF CABLE SLACK AT LOCATION INDICATED. INSTALL CAMERA CENTERED IN CEILING TILE. PROVIDE 4" SQUARE BACK BOX WITH SINGLE GANG TRIM RING AND ONE (1) 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING FOR CABLING AT LOCATIONS INDICATED WITHIN GYP CEILINGS. PROVIDE SURFACE MOUNTED CONDUIT AND BACK BOX IN UNFINISHED AREAS. COORDINATE ROUGH-IN REQUIREMENTS, PENDANT MOUNTS, PROTECTIVE DOMES, AND OTHER REQUIRED ACCESSORIES FOR EXTERIOR CAMERA LOCATIONS WITH SELECTED MANUFACTURER. PROVIDE 20A 120V NORMAL BRANCH CIRCUIT TO CAMERA LOCATIONS AS REQUIRED BY SELECTED MANUFACTURER FOR HEATED ENCLOSURES, PAN-TILT-ZOOM FUNCTIONS, AND ACCESSORIES. COORDINATE CABLING, POWER, AND ROUGH-IN REQUIREMENTS WITH SELECTED MANUFACTURER FOR CAMERA LOCATIONS WITH NETWORK DATA CABLE LENGTHS EXCEEDING 100 METERS. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS. PROVIDE NETWORK DATA CABLES AND JACKS PER SPECIFICATION SECTION 271200. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTION 282300 INCLUDING BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, AND CABLING. SUBMIT SHOP DRAWINGS FOR APPROVAL. COORDINATE EXACT MOUNTING LOCATION WITH OWNER

PRIOR TO INSTALLATION.

SECURITY SURVEILLANCE

CAMERA - WALL

PROVIDE CABLING FOR OWNER PROVIDED POWER OVER ETHERNET (POE) SECURITY SURVEILLANCE CAMERA AS DESCRIBED IN THESE NOTES FOR EACH CAMERA AT LOCATIONS INDICATED. SECURITY SURVEILLANCE COMPONENTS SHALL BE RATED FOR CONTINUOUS OPERATION IN THEIR INSTALLED PROJECT CONDITIONS AS REQUIRED IN SPECIFICATION SECTION 282300. PROVIDE ONE (1) CATEGORY 6A NETWORK DATA CABLE FROM ASSOCIATED COMMUNICATIONS DISTRIBUTION ROOM TO APPROXIMATE LOCATION INDICATED ON FLOOR PLANS.

TERMINATE CABLE WITH RJ45 CONNECTOR. PROVIDE WITH 10' OF CABLE SLACK ABOVE CEILING AT LOCATION INDICATED. PROVIDE 4" SQUARE BACK BOX, MOUNTED AT 84” AFF WITH SINGLE GANG TRIM RING AND ONE (1) 1" CONDUIT TO ABOVE FINISHED ACCESSIBLE CEILING TO ABOVE FINISHED ACCESSIBLE CORRIDOR CEILING TO NEAREST CORRIDOR CABLE TRAY. PROVIDE SURFACE MOUNTED CONDUIT AND BACK BOX IN UNFINISHED AREAS.

COORDINATE ROUGH-IN REQUIREMENTS, PENDANT MOUNTS, PROTECTIVE DOMES, AND OTHER REQUIRED ACCESSORIES FOR EXTERIOR CAMERA LOCATIONS WITH SELECTED MANUFACTURER. PROVIDE 20A 120V NORMAL BRANCH CIRCUIT TO CAMERA LOCATIONS AS REQUIRED BY SELECTED MANUFACTURER FOR HEATED ENCLOSURES, PAN-TILT-ZOOM FUNCTIONS, AND ACCESSORIES. COORDINATE CABLING, POWER, AND ROUGH-IN REQUIREMENTS WITH SELECTED MANUFACTURER FOR CAMERA LOCATIONS WITH NETWORK DATA CABLE LENGTHS EXCEEDING 100 METERS. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS. PROVIDE NETWORK DATA CABLES AND JACKS PER SPECIFICATION SECTION 271200. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTION 282300 INCLUDING BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, AND CABLING. SUBMIT SHOP DRAWINGS FOR APPROVAL. COORDINATE EXACT MOUNTING LOCATION WITH OWNER

PRIOR TO INSTALLATION.

ELECTRICAL MISC SYMBOL LEGEND (TELECOM)

PLAN SYMBOL NAME DESCRIPTION

CABLE TRAY PROVIDE CABLE TRAY AT LOCATIONS INDICATED ON PLANS. REFER TO FLOOR PLANS FOR TYPE DESIGNATION.

COORDINATE MOUNTING WITH OTHER TRADES AND REQUIREMENTS IN SPECIFICATION.

TYPE 'WIDTH x DEPTH", WIRE BASKET CABLE TRAY:

PROVIDE CABLE TRAY IN DIMENSION INDICATED ON FLOOR PLANS.

TYPE 'WIDTH LADDER', LADDER CABLE TRAY:

PROVIDE CABLE TRAY IN DIMENSION INDICATED ON FLOOR PLANS.

CERNER NOTES:

A. ADDITIONAL CERNER DEVICES WILL BE INSTALLED PRIOR TO THIS PROJECT'S COMPLETION.

CONTRACTOR TO INCLUDE AN ALLOWANCE FOR 10 ADDITIONAL 2-PORTS CAT 6A INFORMATION

OUTLETS IN THEIR PROPOSAL. LOCATIONS OF DATA CABLES ARE YET TO BE DETERMINED.

COORDINATE ON EXACT LOCATION OF INSTALLATION WITH VA PROJECT MANAGER.

Revisions: Date:

O R

IG

IN

A L

P R

O P

E R

T Y

L

IN

E

ORIGINAL PROPERTY LINE

ORIGINAL PROPERTY LINE

S

S S

S

S S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

E X

IS

T

IN

G

B U

IL

D

I N G

D E

T A

C H

E D

B U

IL

D

IN

G

S T

A

IR

S

ACCESS RAMP

P A

R K

IN

G

A C

C E

S S

C A

N O

P Y

E X

IS

T

IN

G

B U

IL

D

I N G

E X

IS

T

IN

G

B U

IL

D

I N G

E X

IS

T

IN

G

B U

IL

D

I N G

E X

IS

T

IN

G

B U

IL

D

I N G

E X

IS

T

IN

G

B U

IL

D

I N G

E X

IS

T

IN

G

B U

IL

D

I N G

E X

IS

T

IN

G

P A

R K

IN

G

G A

R A

G E

B U

IL

D

IN

G

C O

L U

M N

T

Y P

O V

E R

H E

A D

W A

L K

W A

Y

L A

N D

S C

A P

E D

A R

E A

L A

N D

S C

A P

E D

A R

E A

C A

N O

P Y

S U

P P

O R

T C

O L

U M

N

T Y

P

LANDSCAPED AREA

LANDSCAPED AREA

O V

E R

H E

A D

W A

L K

W A

Y

D

D

D

D

D D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

' M

E T

A L

R A

IL

IN

G F

E N

C E

' M

E T

A L

R A

IL

IN

G F

E N

C E

' M

E T

A L

R A

IL

IN

G F

E N

C E

' M

E T

A L

R A

IL

IN

G F

E N

C E

' C

H A

IN

L

IN

K

' C

H A

IN

L

IN

K

' C

H A

IN

L

IN

K

C

H A

IN

L

IN

K

T

E M

P O

R A

R Y

C O

N S

T R

U C

T I O

N F

E N

C

IN

G

' M

E T

A L

R A

IL

IN

G F

E N

C E

' M

E T

A L

R A

IL

IN

G F

E N

C E

P

V C

P A

N E

L F

E N

C E

TEMPORARY FENCING

TEM

PO

RAR

Y

FENC

IN

G

U N

K N

O W

N U

T

IL

IT

Y

B O

X

T R

A N

S F

O R

M E

R

P

IE

R C

E A

V E

N U

E

F O

R M

E R

G A

R T

L A

N D

A V

E N

U E

24TH AVENUE SOUTH R.O.W.

R .O

.W

W

ID

T H

U N

C E

R T

A

IN

24TH AVENUE SOUTH R.O.W. WIDTH UNCERTAIN

H

IG

H L A

N D

A V

E N

U E

' R .O

.W

P

P

M H

P

D

M H

A/ C

A/ C

A/ C

M H

A C

A/ C

A/ C

A/ C

E

M H

M H

M H

A C

P

EXISTING (2) 4" C

FROM PIPE

BASEMENT IN ACRE

TO ANNEX BLDG 1A.

B SIDE FIBER

ROUTE.

EXISTING (2) 4"

CONDUIT BETWEEN

BLDG 1 AND ISP#1

PULL BOX. A SIDE

FIBER FROM BLDG1

TO ANNEX BLDG 1A.

AT&T SERVICE

CIRCUIT #1

EXISTING CENTURYLINK\

LUMEN SERVICE. NEW

DIVERSE ISP ROUTE BEING

BUILT ON OTHER SIDE OF

BUILDING 1

EXISTING

COMMUNICATIONS

PULLBOX

EXISTING FIBER

ROUTE. (2) 4" C.

ROUTE FOR A AND B

SIDE FIBER

NEW MAIN

COMPUTER ROOM

LOCATION ON ROOF

OF BUILDING 1 FIRST

FLOOR, ROOM A-280

EXISTING MAIN COMPUTER ROOM

AND ENTRANCE ROOM 2 FOR

CENTURYLINK\LUMEN SERVICE IN

BUILDING 1 ROOM D-03. MAIN

COMPUTER ROOM MOVING TO

ROOF OF FIRST FLOOR. ROOM

A-280 ENTRANCE ROOM 2 MOVING

TO TR, D-201.

EXISTING ENTRANCE

ROOM 1. AT&T SERVICE IN

BUILDING 1 BASEMENT

ROOM A22.

LINE TYPE KEY

SIDE A

SIDE B

EXISTING PATHWAYS

NEW DUCTBANK

ENTRANCE POINT 1

ENTRANCE POINT 2

FUTURE ROOM FOR AT&T

\LUMEN CIRCUIT #2 AND

TR (ROOM D-201).

NEW AT&T\LUMEN CIRCUIT PATH #

2, INSTALLED BY TELCO PROVIDER

ON AERIAL POLES.

EXISTING VA

COMMUNICATIONS

PULLBOX.

NEW (2) 4" C (PVC) FOR AT&T

\LUMEN CIRCUIT #2.

NEW PULLBOX OUTSIDE OF BUILDING 1

(SEE SHEET T508 DETAIL #2)

MAIN POINT OF

ENTRY 3.

NEW 2'X2'

PULLBOX.

NEW 2" C (IMC) FOR AT&T

\LUMEN CIRCUIT #2 FROM

MAIN POINT OF ENTRY 3 TO

ROOM C-07E IN BASEMENT.

NEW 2" C (EMT) (WITH 24

STRANDS OF OM4 AND 12

STRANDS PF OS1) BETWEEN

EXISTING AT&T CIRCUIT #1

AND NEW MCR. (PATH INTO

NEW MCR IS THROUGH THE

CEILING OF EXISTING TR

D-103).

NEW 2" C (EMT) BETWEEN

EXISTING MCR AND NEW MCR.

MCR CROSS-CONNECT HYBRID

FIBER. (WITH 24 STRANDS OF OM4

AND 12 STRANDS OF OS1)(PATH

INTO NEW MCR IS THROUGH THE

CEILING OF EXISTING TR D-103).

NEW (2) 4" C (PVC)

FOR A SIDE FIBER

ROOM C-07E IN

BASEMENT

T508

NEW 2" C (EMT) FOR AT&T

\LUMEN CIRCUIT #2 FROM C-07E

TO ROOM D-001. CIRCUIT #2

THEN EXTENDS FROM D-001 TO

D-201 THROUGH VERTICAL 2" C

IN STACKED TRS.

NEW 2" C (EMT) (WITH 24 STRANDS

OF OM4 AND 12 STRANDS OF OS1)

FOR FUTURE AT&T\LUMEN CIRCUIT #2

FROM D-201 TO NEW MCR (A-280)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL BID

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 22328

A u to d e s k D o c s /2

N a s h v ill e E

H R

M /6

-7

.B

.E

T

R

.r v t

/1

/2

:4

:4

P

M

T001

TELECOMMUNICATIONS - SITE PLAN EHRM INFRASTRUCTURE

UPGRADES DESIGN

1310 24TH Avenue South Nashville, TN 37212

626-22-700

02/16/2024 NMT SSK

SCALE: 1" = 40'-0"T001

1 SITE PLAN - TELECOMMUNICATIONS N

SHEET NOTES:

1. LOCAL SERVICE PROVIDERS TO PULL NEW SERVICE FIBER THROUGH

EXISTING PATHWAYS INTO BUILDING 1. CONDUIT BETWEEN EXISTING

SERVICE ENTRANCE POINT 1 AND ENTRANCE ROOM 1 (A-22) WILL REMAIN

AS IS. CONTRACTOR TO INSTALL A 2" C (IMT) FROM MAIN POINT OF ENTRY 3

TO ROOM C-07E. A 2" CONDUIT WILL BE INSTALLED BETWEEN SERVICE

ENTRANCE 2 AND ENTRANCE ROOM 2 ON THE SECOND FLOOR. PULL BOXES

WILL BE INCLUDED WITHIN PATHWAYS TO ALLOW FOR EASE OF

INSTALLATION.

2. CONTRACTOR TO PERFORM A UTILITY LOCATE PRIOR TO STARTING WORK

AND TO HAND DIG AROUND EXISTING UTILITIES.

A. REFER TO SHEET T000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY

SYMBOL LIST AND GENERAL DEMOLITION NOTES FOR ADDITIONAL

DEMOLITION SCOPE.

B. SEE CIVIL SHEETS FOR DETAILED WORK ON NEW DUCT BANK.

C. THIS PLAN SHOWS THE SITE AND PIPE TUNNELS. INTRA-BUILDING ROUTES

ARE FOR VISUAL PURPOSES AND DO NOT REFLECT THE ACTUAL ROUTE.

REFER TO OVERALL SHEETS T002 through T010 FOR THE ACTUAL PATH OF

BACKBONE FIBER ROUTING IN THE BUILDING.

GENERAL NOTE:

0' 20' 40' 80'

J

3A

2A

2A →

1A

1B

1A → 1B ←

2B

3A ←

1A ← 2A → 1B ←

1B

1B ←

1B

1B

1B ←

1B

1B ←

3B

3B ←

2B

2B

2B

2B ←

2B

2B

1A

1B

1A

2A

2A

2A →

2A

1A ← 1B ←

31B

1B

1A → 1B ←

1BI

1AI

1A 1B

1A 1B

1A 1B

1B ←

NEW TR

D-57A

NEW TR

D-001

NEW TR

A-11

NEW TR

E-15

1A 1B 16

14 13

#A A SIDE FIBER = NUMBER OF 24 STRAND OM4 MULTIMODE + 12 STRAND OS1

SINGLE MODE INDOOR TIGHT BUFFERED PLENUM ARMORED HYBRID CABLE

#B B SIDE FIBER = NUMBER OF 24 STRAND OM4 MULTIMODE + 12 STRAND OS1

SINGLE MODE INDOOR TIGHT BUFFERED PLENUM ARMORED HYBRID CABLE

#AI A SIDE INTER-BUILDING FIBER (AI) = NUMBER OF 24 STRAND SINGLE MODE OS2

INDOOR/OUTDOOR LOOSE TUBE CABLE.

#BI B SIDE INTER-BUILDING FIBER (BI) = NUMBER OF 24 STRAND SINGLE MODE OS2

INDOOR/OUTDOOR LOOSE TUBE CABLE.

MCR INTERCONNECT CABLE BETWEEN EXISTING MCR AND NEW MCR. 24 STRAND

OM4 MULTIMODE + 12 STRAND OS1 SINGLE MODE INDOOR TIGHT BUFFERED

PLENUM ARMORED HYBRID CABLE.

DEMARC CONNECTION BETWEEN ENTRANCE ROOM AND NEW MCR. 24 STRAND OM4

MULTIMODE + 12 STRAND OS1 SINGLE MODE INDOOR TIGHT BUFFERED PLENUM

ARMORED HYBRID CABLE.

FIBER LEGEND

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL BID

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

SES Project : 22328

KEYPLAN N

ACRE

A BW

CE DE

1A

BE

CW DW

A u to d e s k D o c s /2

N a s h v ill e E

H R

M /6

-7

.B

.E

T

R

.r v t

/1

/2

:4

:5

P

M

T002

BASEMENT LEVEL FLOOR PLAN - OVERALL -

INTRA-BUILDING FIBER ROUTING DIAGRAM -

B01

EHRM INFRASTRUCTURE

UPGRADES DESIGN

1310 24TH Avenue South Nashville, TN 37212

626-22-700

B01

02/16/2024 NMT SSK

0' 20' 40' 80' N

SCALE: 1/32" = 1'-0"T002

1 BASEMENT LEVEL FLOOR PLAN - OVERALL - INTRA-BUILDING FIBER ROUTING DIAGRAM

GENERAL NOTES:

A. REFER TO SHEET TN000 TECHNOLOGY COVERSHEET FOR TECHNOLOGY SYMBOL

LIST AND GENERAL DEMOLITION NOTES FOR ADDITIONAL DEMOLITION SCOPE.

B. CONTRACTOR TO FIELD VERIFY CONDUIT RISER ROUTE WITH OWNER PRIOR TO

INSTALLATION.

C. WHEN A-LEG AND B-LEG FIBERS ARE RUN IN THE SAME CORRIDOR, IN OPPOSITE

DIRECTIONS, BOTH FIBER MAY BE PLACED IN THE SAME CABLE TRAY. WHEN A-

LEG AND B-LEG FIBERS ARE IN THE SAME CORRIDOR, AND RUN THE SAME

DIRECTION FOR MORE THAN 40 FEET, MAINTAIN A MINIMUM OF 6' OF SEPARATION.

D. PROVIDE JUNCTION BOX WHEN CONNECTING NEW CONDUIT TO EXISTING

CONDUIT INFRASTRUCTURE. CONTRACTOR TO PROVIDE AS BUILT DRAWINGS

INDICATING JUNCTION BOX LOCATIONS.

E. PROVIDE #3/0 COPPER IN 1" PVC CONDUIT FROM SECONDARY GROUND BAR IN

EACH TR TO THE TELECOMMUNICATIONS MAIN GROUND BAR LOCATED IN THE

MAIN SERVER ROOM (ROOM A-280). SEE ASSOCIATED ENLARGED PLAN FOR EACH

TR FOR GROUND BAR LOCATION.

SHEET NOTES:

1. PROVIDE NEW JUNCTION BOX TO CONNECT EXISTING (2) 4"C, AND 2" C WITH

BI CABLE, IN PIPE BASEMENT TO BLD. 1A ANNEX. FIELD VERIFY EXACT

ROUTING WITH VA PRIOR TO BEGINNING WORK.

2. PROVIDE (1) AI CABLE IN 2" C AS SHOWN FROM NEW MCR THROUGH MAIN

POINT OF ENTRY #1 TO BLDG 1A ANNEX TR.

3. TRANSITION DESIGNATED CABLE FROM CABLE TRAY TO NEW J-HOOK PATH

AS SHOWN.

4. PROVIDE (1) AI CABLE IN 2" C. AS SHOWN FROM ROOM D-111 TO C-07E.

5. PROVIDE (1) BI CABLE IN 2" C. AS SHOWN FROM ROOM D-001 TO C-07E.

6. ROUTE (1) MCR CABLE IN 2" C FROM ROOM D-03 TO CEILING RISER IN A-17.

7. ROUTE (1) DEMARC CABLE IN 2" C FOR AT&T CIRCUIT FROM A-22 TO CEILING

RISER IN A-17.

8. ROUTE (1) AI AND (1) BI IN SEPARATE 2" C FROM ROOM C-07E DOWN TO PIPE

BASEMENT.

9. CONNECT TO EXISTING (2) 4" C. IN PIPE BASEMENT FROM BLD. 1 TO THE

BASEMENT OF THE PARKING GARAGE.

10. RISER IN THE CEILING OF ROOM A-17.

11. RISER CLOSET FROM PIPE BASEMENT TO FIRST FLOOR.

12. NEW EXTERNAL PULLBOX THAT ACCEPTS (2) 4" C.

13. NEW INTERNAL PULLBOX THAT ACCEPTS (2) 4" C TO (1) 2" C.

14. PROVIDE 2" CONDUIT (IMC OR RMC) FOR LUMEN CIRCUIT UP FROM PIPE

BASEMENT TO ROOM C-07E.

15. NEW 2" C (EMT) FOR LUMEN CIRCUIT #2 FROM C-07E TO D-001.

16. LUMEN CIRCUIT #2 EXTENDS FROM D-001 TO D-201 THROUGH VERTICAL 2" C

IN STACKED TRS.

7A →

6A

5A

1B

4A

5A → 1B ←

5B ← 5B ←

5A

5B

B

17A ←9A ←

6A

1A ←

4A

1B → 1B

1A

1A →

10 11

5A →

1A

1A → 1A

B

1A

B

22B ←

2AI

1BI

1BI

1B

1B →

1B →

1B

22B ←22 B

1B ←

1B

B

15B →

6B

5A →

5A

B

B

14B → 14B →

B

B

B

14B

(1) BI

5A →

8A

6A

6A

2AI

1BI

4A →4A →

1A 1B

4A →

1A 1B

1A 1B

1A 1B

7A

8A

NEW TR

E-103A

NEW TR

D-101

NEW TR

A-116

NEW TR

D-114S

#A A SIDE FIBER = NUMBER OF 24 STRAND OM4 MULTIMODE + 12 STRAND OS1

SINGLE MODE INDOOR TIGHT BUFFERED PLENUM ARMORED HYBRID CABLE

#B B SIDE FIBER = NUMBER OF 24 STRAND OM4 MULTIMODE + 12 STRAND OS1

SINGLE MODE INDOOR TIGHT BUFFERED PLENUM ARMORED HYBRID CABLE

#AI A SIDE…