This manual provides operations and maintenance instructions for a screw conveyor system used to collect and transport lead materials from a shooting range. The manual covers screw conveyor manufacturing, safety warnings, system operation including start-up procedures, and maintenance requirements. Periodic maintenance tasks are outlined, including daily, three-month, and troubleshooting procedures. Warnings and disclaimers address proper usage, personal protective equipment, and liability.
The related federal contract opportunity is a solicitation from the Department of the Air Force seeking proposals for CATM range maintenance services at Moody Air Force Base. Services required include maintenance and repair of range infrastructure and equipment such as target systems, bullet containment materials and structures, range scheduling software, and other small arms range assets. The solicitation includes standard terms for small business set-asides and provides incumbent information but no pricing, award dates or response deadlines.
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Screw Conveyor System Operations/Maintenance Manual
PO Box 636, Provo, UT 84603,801-377-8033
Use and Operation Screw Conveyor System
The data contained herein is disclosed for the sole purpose of assist-ing the user in the operation of Action Target equipment. All data and specifications are subject to change without notice. This data is appli-cable only to the part name/number identified. Some products may be customized for specific use, so your product may differ from that de-scribed herein.
Action Target Inc.
Assembly:@:B_sc Version: 1.00 Printed: 2011-Oct-03
Table of Contents
1. Screw Conveyor Manufacturing
1.1. Product Description
1.2. Receiving and Inspection
1.3. Screw Conveyor Trough Assembly
2. Warning and Safety Instructions
2.1. General Safety Precautions
2.2. Electrical
2.3. Safety Labels
3. Screw Conveyor Operation
3.1. Operating Safety
3.2. Initial Start-up (without material)
3.3. Initial Start-up (with material)
3.3.1. Start/Stop Controls
3.3.2. Timer Switch Control Operation
3.3.3. New Ranges and Lead Particulates
3.4. Extended Shut Down
4. Screw Conveyor Maintenance
4.1. Conveyor Component Servicing
4.1.1. Conventional Conveyor Screws
4.1.2. Coupling and Hangers
4.1.3. Lubrication
4.1.4. Drive
4.1.5. Ball or Roller Bearings
4.1.6. Other Bearings
4.2. Periodic Maintenance
4.2.1. Daily Maintenance
4.2.2. Three-Month Maintenance
4.2.3. Troubleshooting Electrical
5. Safety
6. Disclaimer
7. Warranties and Returns
ACTION TARGET • PO BOX 636 • PROVO, UT 84603 • 801-377-8033 •WWW.ACTIONTARGET.COM 2
1. Screw Conveyor Manufacturing
Most components are manufactured to the standards of the Conveyor Equipment Manufactures Association (CEMA). Manufacturers design and manufacture special components for unusual requirements. Conveyors can be ordered as individual components for aligning and assembling in the field. When the manufacturer engineers the conveyor, complete specification drawings are generally furnished. Always follow the manufacturer's instructions.
1.1. Product Description
The Screw-Conveyor System (SCS) is a helicoid conveyor screw with a U-shaped flange formed trough. The SCS is designed to collect, move, and distribute lead, brass and other slug and projectile materials from the trap to a central discharge location. As projectiles fall from the trap collection chamber, they are pulled away by a powerful helicoid screw and safely deposited typically in a large barrel for truly hands-free operation.
1.2. Receiving and Inspection
Because of variations in length and installation conditions, screw conveyors are usually shippedas sub-assem-blies. Check all assemblies and parts against shipping papers, and inspect for damage on arrival. Look for dented or bent trough and bent flanges, flighting, pipe or hangers. Minor damage incurred in shipping can be readily repaired in the field. For severely damaged parts, file an immediate claim with the carrier. Before pro-ceedingwith erection, ensure that the supplementary instructions are included. If anything is missing, consult the supplier.
1.3. Screw Conveyor Trough Assembly
Screw conveyor troughs must be assembled straight and true with no distortion. If anchor bolts are not in line, either move them or slot the conveyor feet or saddle holes. Use shims under feet as required to achieve correct alignment. Do not proceed with installation of shafts and screws until trough has been completely aligned and bolted down. For further install and erection information see Installation Manual.
2. Warning and Safety Instructions
2.1. General Safety Precautions
It is the responsibility of the owner and user to maintain and operate the conveyor, components and, conveyor assemblies in such amanner as to comply with the Williams-Steiger Occupational Safety and Health Act and with all state and local laws and ordinances and the American National Standards Institute (ANSI) B20.1 Safety Code.
In order to avoid an unsafe or hazardous condition, the assemblies or parts must be installed and operated in accordance with the followingMINIMUM provisions.
1. Conveyors shall not be operated unless all covers and/or guards for the conveyor and drive unit are in place. If the conveyor is to be opened for inspection cleaning,maintenance or observation, the electric power to the motor driving the conveyor must be LOCKED OUT in such a manner that the conveyor cannot be restarted by anyone; however remote from the area, until conveyor cover or guards and drive guards have been properly replaced.
2. If the conveyor must have an open housing as a condition of its use and application, the entire conveyor is then to be guarded by a railing or fence in accordance with ANSI standard B20.1.(Request current edition and addenda)
3. Feed openings for shovel, front loaders or other manual or mechanical equipment shall be constructed in such a way that the conveyor opening is covered by a grating. If the nature of the material is such that a grating cannot be used, then the exposed section of the conveyor is to be guarded by a railing or fence and there shall be a warning sign posted.
4. Do not attempt any maintenance or repairs of the conveyor until power has been LOCKED OUT.
ACTION TARGET • PO BOX 636 • PROVO, UT 84603 • 801-377-8033 •WWW.ACTIONTARGET.COM 3
5. Always operate conveyor in accordance with these instructions and those contained on the caution labels affixed to the equipment.
6. Do not place hands, feet, or any part of your body, in the conveyor.
7. Never walk on conveyor covers, grating or guards.
8. Do not use conveyor for any purpose other than that for which it was intended.
9. Do not poke or prod material into the conveyor with a bar or stick inserted through the openings.
10. Keep the area around conveyor drive and control station free of debris and obstacles.
11. Eliminate all sources of stored energy (materials or devices that could cause conveyor components to move without power applied) before opening the conveyor
12. Do not attempt to clear a jammed conveyor until power has been LOCKED OUT.
13. Do not attempt field modification of conveyor or components.
14.Conveyors are not normallymanufacturedor designedto handlematerials that are hazardous to personnel.
These materials which are hazardous include those that are explosive, flammable, toxic or otherwise danger-ous to personnel. Conveyors may be designed to handle these materials. Conveyors are not manufactured or designed to comply with local, state or federal codes for unfired pressure vessels. If hazardous materials are to be conveyed or if the conveyor is to be subjected to internal or external pressure, manufacturer should be consulted prior to any modifications.
2.2. Electrical
Warning! Action Target insists that disconnecting and locking out the power to the motor driving the unit provides the only real protection against injury!
Secondary safety devices are available; however, the decision as to their need and the type required must be made by the owner-assembler as we have no information regarding plant wiring, plant environment, the interlocking of the screw conveyor with other equipment, extent of plant automation, etc. Other devices should not be used as a substitute for locking out the power prior to removing guards or covers. We caution that use of the secondary devices may cause employees to develop a false sense of security and fail to lock out power before removing covers or guards. This could result in a serious injury should the secondary device fail or malfunction.
There are many kinds of electrical devices for interlocking of conveyors and conveyor systems such that if one conveyor in a system or process is stopped other equipment feeding it, or following it can also be automatically stopped.
Electrical controls, machinery guards, railings, walkways, arrangement of installation, training of personnel, etc., are necessary ingredients for a safe working place. It is the responsibility of the contractor, installer, owner and user to supplement the materials and services furnished with these necessary items to make the conveyor installation comply with the law and accepted standards.
Conveyor inlet and discharge openings are designed to connect to other equipment or machinery so that the flow of material into and out of the conveyor is completely enclosed.
2.3. Safety Labels
One or more warning labels should be visible on conveyor housings, conveyor covers and elevator housings (See Figure 2). If the labels attached to the equipment become illegible, please order replacement warning labels from the OEM or CEMA.
The Conveyor Equipment Manufacturers Association (CEMA) has produced an audio-visual presentation entitled "Safe Operation of Screw Conveyors, Drag Conveyors, and Bucket Elevators." CEMA encourages acquisition and use of this source of safety information to supplement your safety program.
ACTION TARGET • PO BOX 636 • PROVO, UT 84603 • 801-377-8033 •WWW.ACTIONTARGET.COM 4
3. Screw Conveyor Operation
3.1. Operating Safety
Warning! Only persons completely familiar with the following precautions should be permitted to operate the conveyor! The operator should thoroughly understand these instructions before attempting to use the conveyor. Failure to follow these precautions may result in serious injury or damage to equipment!
To help promote safety and help reduce accidents, CEMA has made available a VHS videotape presentation designed to demonstrate the basic rules for safe operation of screw conveyors. Contact CEMA for details about the video "Screw Conveyors, Drag Conveyors, and Bucket Elevator Safety Video".
1. ALWAYS operate conveyor in accordance with these instructions and those Safety Precautions previously mentioned in this chapter.
2. DO NOT place hands or feet in conveyor opening.
3. NEVER walk on conveyor covers or gratings.
4. DO NOT put conveyor to any other use than that for which it was designed.
5. AVOID poking or prodding material in conveyor with a bar or stick inserted through openings.
6. ALWAYS have a clear view of conveyor loading and unloading points and all safety devices.
7. Keep area around conveyor, drive, and control station free of debris and obstacles.
8. NEVER operate conveyor without covers, grating, guards and other safety devices in
3.2. Initial Start-up (without material)
1. REMEMBER that the screw conveyor is generally shippedWITHOUT oil. Add oil to drive in accordance with manufacturer's instructions.
2. ENSURE before initial start-up that the conveyor is empty, the end bearings and hangers are lubricated, and that all covers, guards, and safety equipment are properly installed.
3. If the conveyor is part of a material handling system, ensure that the conveyor controls are interlocked electrically with those for other units in the system.
4. Check the direction of conveyor rotation in each unit to ensure correct material flow.
5. Operate the conveyor while empty for several hours, making continuous checks for bearings heating, drive misalignment, and noisy operation. If any of these occur, proceed as follows:
a. If anti-friction bearings are used, check the lubricant supply. Either too little or too much lubricant can cause high operating temperatures.
b. Lock out the power supply and check for misalignment in the trough ends, screws and hangers. Loosen and readjust or shim as necessary. If unable to eliminate misalignment, check parts for possible damage during shipment.
c. Check assembly and mounting bolts.
6. Some drive movement may be experienced when operating the conveyor. If the movement is excessive, the cause may be a bent screw, improper installation, hanger bearing wear, or shaft or internal collar wear.
Consult with the conveyor manufacturer for drive specifications.
The Screw Conveyor requires periodic maintenance. If this maintenance is not performed according to the manufacturers requirements, resulting conditions are not covered under the manufacturers standard war-ranty.
3.3. Initial Start-up (withmaterial)
Perform Daily Maintenance before operating the system. See Section 4.2.1, Daily Maintenance.
ACTION TARGET • PO BOX 636 • PROVO, UT 84603 • 801-377-8033 •WWW.ACTIONTARGET.COM 5
Once Daily Maintenance is performed, range personnel can safely engage the auger system. There are two main ways to control the SCS. First, there is a Push Button Start/Stop switch. Second, there is a timer switch control.
3.3.1. Start/Stop Controls
Caution! Check that the conveyor discharge is clear before feeding material!
The user controls for the SCS consist of two buttons: "start" and "stop" as shown in Figure 1.
Note: The exact location of these controls may be different for each installation. In installations where the operation of the SCS can not be detected audibly, there may also be an optional "power-on" indicator light on the user control panel.
Increase feed rate gradually until the rated capacity is reached by following these instructions:
1. To begin operation, depress and hold the start button down.
When proper operating speed is achieved, you may release the start button. If the start button is released before the speed is obtained, the SCS enters a shutdown state and cannot operate properly until the start sequence is executed properly.
2. Stop and start the conveyor several times and allow it to operate for several hours.
3. When use of the SCS is concluded, press the stop button momentarily. This removes power to the unit.
The unit may be safely left in this state overnight or for extended periods of time. If it is desired that the unit be unusable for a period of time, remove power to the system by turning off the main breakers (120V control voltage and 3 phase motor voltage), or turn off and lock the local disconnect.
START
STOP
Figure 1. Start/Stop Switch
3.3.2. Timer Switch Control Operation
There is a switch labeled, "Auto, Off, Manual" which is located downrange by the auger itself or may be located up-range if the range has wiring for remote control. The auger system may be engaged by turning the switch to a manual or auto mode. Generally, one system or the other will be operational and the other will be disabled.
If the manual mode is operational, turning the switch to "Manual" causes the auger system to run continuously until turned to the "Off" position. This mode should not be left on continuously for more than is necessary to clear the auger of accumulated lead in the trough.
Note: The time left running and the frequency run depend upon range usage.
If the auto mode is operational, turning the switch to "Auto" causes the auger system to run periodically until turned to the "Off" position. This system is controlled through a timer which is located next to the auger controls. Standard recommended setting of this timer should be to run 15 minutes, resting 45 minutes, and running again for 15 minutes. Repeat this sequence until the switch is turned from "Auto" to "Off".
The timer may be reset according to range usage. Follow the manufacturer's instructions included with the
ACTION TARGET • PO BOX 636 • PROVO, UT 84603 • 801-377-8033 •WWW.ACTIONTARGET.COM 6 timer for resetting.
Note: The auger system should never be permitted to fill more than the auger is able to move through the entire length of the trough at one time. Turning on the auger frequently to expel the lead is advised, while leaving on for more than necessary may cause premature motor fatigue. Continual adjustment is need depending on the use and volume of your particular range.
3.3.3. New Ranges and Lead Particulates
It is expected that some level of lead particulates may remain in the trough. It may take some time before lead builds up enough inside the trough to be moved by the screw towards the barrel. The design is not to "clean 100%" of the trough each time the system is engaged, but to remove the majority of the lead towards the take away arm into the barrel.
When the conveyor is running there is a audible sound of the particulates dropping into the barrel. As the sound lessens (decreases), this indicates that the troughs are clear from a running purpose. The 100% clear cannot happen as there is a clearance where some debris settles to the bottombeyond the reach of the screw.
The drum is checked by tapping on its side. When the tapping makes a "thud" sound half way up, then the barrel is full and should be changed out.
Note:Neither "Manual" or "Auto" modes should be left in the on position unless range personnel are present.
The system should be in the "Off" position during non-use times.
3.4. Extended Shut Down
If the conveyor is to be inoperative for a long period of time, it is advisable to permit it to operate for a period of time after the feed had been cut off in order to discharge as much material as possible from the trough.
However, there is a nominal clearance of ½" between the screw and the trough, and this procedure allows a small amount of material to remain in the trough. Therefore, if the material is corrosive, hygroscopic, or has a tendency to harden or set up, the trough should be cleaned completely after the conveyor is shut down and the power locked out.
4. Screw Conveyor Maintenance
Establish routine periodic inspection of the entire conveyor to insure continuous maximum operating performance. Practice good housekeeping. Keep the area around the conveyor and drive clean and free of obstacles to provide easy access and to avoid interference with the function of the conveyor or drive.
1. Lock out power to motor before doing any maintenance work - preferably with a padlock on control.
2. Do not remove padlock from control, or operate the conveyor until covers and guards are securely in place.
4.1. Conveyor Component Servicing
In most cases this involves removing an unserviceable part and installing a replacement. The installation procedures are outlined in the Installation Manual. Specific instructions for the removal of various conveyor components follow.
4.1.1. Conventional Conveyor Screws
To remove a section or sections of conventional conveyor screw:
1. Proceed from the end opposite the drive.
2.Remove the trough end, conveyor screw section(s), coupling shafts, and hangers until all the screw sections have been removed, or until the damaged or worn section(s) is/are removed.
To reassemble:
1. Follow the above steps in reverse order, or see the assembly instructions in the Installation Manual.
Note: Sections of conventional conveyor screw equipped with split flight couplings may be removed individually with a minimum of disturbance of adjacent sections.
ACTION TARGET • PO BOX 636 • PROVO, UT 84603 • 801-377-8033 •WWW.ACTIONTARGET.COM 7
4.1.2. Coupling and Hangers
Replace couplings and hanger bearings when wear in either part exceeds 1/8 “.
Replace coupling bolts when excessive wear causes play.
4.1.3. Lubrication
Lubrication frequency depends on factors such as the nature of the application, the specific parts, bearing materials, and operating conditions.Weekly inspection and lubrication is advisable until sufficient experience permits the establishment of an optimal lubrication interval.
Hint: Follow the manufacturer's initial recommendations for lubrication and then include your operating con-ditions.
4.1.4. Drive
Lubricate the drive following the manufacturer's instructions provided for the speed reducer and other drive components requiring lubrication. Speed reducers are generally shipped WITHOUT oil.
4.1.5. Ball or Roller Bearings
Ball and roller bearings may be furnished in trough ends or hangers. Lubricate in accordance with the manufacturer's provided instructions.
4.1.6. Other Bearings
No lubrication is required for oil-less or graphite bronze, hard or chilled iron, oil impregnated wood, or plastic laminate hanger bearings.
4.2. Periodic Maintenance
Establish routine periodic inspection of the entire conveyor to ensure continuous maximum operating performance. Practice good housekeeping. Keep the area around the conveyor and drive clean and free of obstacles to provide easy access and to avoid interference with the function of the conveyor or drive.
1. Lock out power to the motor before doing any maintenance work - preferably with a padlock on control.
2. Do not remove padlock from control, or operate the conveyor until covers and guards are securely in place.
4.2.1. Daily Maintenance
Before turning on the system, a daily check of the lead level in the barrel must be performed by range personnel. Range personnel should record this check daily in a log.
When the barrel reaches ½ full, the system should not be used until the ½ full barrel has been replaced with an empty barrel. Any time the barrel seal is broken and the lid removed, appropriate safety equipment is required includingHEPA rated protection for lead particulates. To replace the drum, remove the ring seal from the lid, and lift up the lid. Attach the eyelets on the lid to the chains provided on the take away arm. The ½ full barrel should be recapped and sealed before moving.
Note:A pallet should be placed under the new barrel before re-installation.Barrels should be DOT rated along with lids and seals. Reattach the lid to the new barrel ensuring that the ring and seal are intact. The power to the system may be turned back on and the system may now be engaged.
4.2.2. Three-MonthMaintenance
Periodic maintenance of the auger must also be performed and logged by the range personnel. The following procedures must be performed every 3 months or 500 operating hours. Youmay need to perform these steps more often if heavy weather conditions occur during system use.
1. There are "grease zerks" on each end of the auger screw. A typical range consists of a main screw line under the chambers and a take away arm leading to a barrel. Each of these screws has a zerk at each end.
Apply with a standard grease gun until grease may be seen leaving from the bearing.When lubricating, follow all applicable safety procedures. Refer to Section 4.1.3.
ACTION TARGET • PO BOX 636 • PROVO, UT 84603 • 801-377-8033 •WWW.ACTIONTARGET.COM 8
2. There is an oil level that needs checking in the gearbox located next to the motors. When the cap is removed, the oil level should be visible. If low, fill with 90 weight gear oil until visible. The oil should be totally drained and replaced annually with 90 weight gear oil.
Warning!Do not operate without proper oil and oil level in the gearbox!When lubricating, follow all applicable safety procedures. Refer to Section 4.1.3.
3. There is a drive chain located next to each motor. The chain guard cover must be removed and the chain lubricated with a water displacing lubricant. Follow the safety instructions found in procedure 10 when applying lubricant to these parts and frequency according to procedure 11.
4.2.3. Troubleshooting Electrical
Each motor has an overload relay. For a system powered by 480V power, the overload relay is 5-amps. For a system powered by 208V power, the overload relay is 12-amps. There is also a buss fuse for each line of power. 480V uses a 5-amp buss fuse and 208V use a 12-amp fuse. If the system does not respond when the switch is turned to "Auto" or "Manual", these overload relays or fuses must be checked.
Warning! Replacement of relays or fuses must be done by a qualified/licensed electrician!
Any questions regarding the operation or maintenance of the Screw Conveyor System that this manual does not address may be directed to the Customer Service Department of Action Target Inc. 1-801-377-8033.
ACTION TARGET • PO BOX 636 • PROVO, UT 84603 • 801-377-8033 •WWW.ACTIONTARGET.COM 9
Screw Conveyors
Do Not Climb, Sit, Stand or Walk, On Conveyor At Any Time
Do Not Perform Maintenance on
Conveyor Until Electrical, AIr, Hudraulic and Gravity Energy
Sources Have Been Locked Out and Blocked
Operate Equipment Only With All
Approved Covers and Guards in
Place
Keep Clothing, Body Parts, and
Hair Away from Conveyors
Ensure That All Personnel Are
Clear of Equipment Before
Starting.
Allow Only Authorized And
Trained Personnel To Operate or Maintain Conveyors and
Accessories
LOCK OUT ALL Power and Block
Gravity Loads Before Servicing.
Clean Up Spillage Near Moving
Parts ONLY When the Power Is
Locked Out AND Guards Are In
Place.
DO NOT Modify Conveyor or Controls
Ensure That All Controls are
Visible and Accessible
Operate Equipment Only With All
Approved Covers, Guards, and
Safety Labels In Place
Report All Unsafe Conditions
POST IN PROMINENT AREA
1234567890123 1234567890123 1234567890123 1234567890123 1234567890123 1234567890123 1234567890123 1234567890123 1234567890123 1234567890123 1234567890123 1234567890123 1234567890123
Figure 2. Safety andWarning Labels
ACTION TARGET • PO BOX 636 • PROVO, UT 84603 • 801-377-8033 •WWW.ACTIONTARGET.COM 10
5. Safety
Action Target shooting targets are designed to reduce but cannot control the amount of bullet splatter that may be returned to the shooting area. Consequently, appropriate eye protection and protective clothingmust be worn by shooters and bystanders when shooting at any type of steel target or target that uses a steel mounting frame or steel components.
Any activity using firearms is inherently dangerous and should only be carried out with the greatest of care and seriousness. This equipment is intended for professional use, not for consumer or amusement activities!
It should only be used under the strict supervision of qualified firearms training personnel.
Action Target will assume no responsibility whatsoever for persons or organizations who use Action Target equipment in a manner which is unsafe and/or which poses a threat to human life, property, or the envi-ronment.
Action Target is not responsible for contamination, environmental damage, or any other consequences or outcomes the results of range operations.
Caution! Action Target highly recommends that you follow your range safety program and strictly adhere to its rules!
For protection, all range personnel should adhere to these safety precautions:
* Keep hands and clothing clear of any moving parts, actuators, motors, etc.
* Always use proper armament in front of actuators, air lines, controllers, fixtures, and any other parts of the system which might be damaged by gunfire.
* Never place a target in a location that can be seen from anywhere other than the area where the intended shooter is firing from!
* Always use proper armament in front of actuators, air lines, controllers, fixtures, and any other parts of an ATI system that might be damaged by gunfire.
* Wear appropriate clothing.
* Wear appropriate eye and hearing protection.
* Vary target placement whenever possible to distribute spent rounds more evenly over bullet trap surfaces.
* Watch for airborne fragmentation from fired rounds.
* Halt all shooting activity and correct the reason for any airborne fragmentation.
* Watch for splatter from bullets impacting the ground or other surfaces.
* Halt all shooting activity and correct the reason for any splatter.
* Follow inspection schedules and preventative maintenance procedures for target equipment and bullet traps.
* Inspect ranges regularly per the recommended inspection and repair sections of the specific ATI manual.
* Halt all shooting activity and inspect range conditions when smoke or sparks are seen where bullets impact.
* Halt all shooting activity and inspect any changes in the appearance of the bullet trap or other range equipment.
ACTION TARGET • PO BOX 636 • PROVO, UT 84603 • 801-377-8033 •WWW.ACTIONTARGET.COM 11
6. Disclaimer
Certain risks are inherent in the use of firearms and participation in live-fire training programs. In addition, the improper use of firearms in live-fire training can lead to the destruction of property, personal injury, and even death. You and your customers must follow all manufacturers' instructions when using firearms with any Action Target, Inc. product.
Action Target products are intended for use only under the close supervision and direction of a qualified firearms instructor experienced in live-fire training. The risks associated with firearms training must be carefully considered and evaluated when planning and implementing the use of any Action Target product.
Further, every firearms user must fully understand and evaluate the destructive and penetrating potential of any ammunition selected. Prior to using Action Target, Inc. products, the firearms user must evaluate the performance characteristics of the ammunition in use and ensure that it cannot penetrate or damage AR 500 steel, or a combination of crushed rock and AR 500 steel. If in doubt, firearms users should consult the ammunition's manufacturer for performance characteristics.
Warning! You and your customers must not use any Armor Piercing (AP) or other penetrative ammunition in conjunction with any Action Target, Inc. product. Use of penetrative ammunition could result in serious damage to the product, breaching of the fired-round containment area, and serious injury or even death!
Action Target, Inc.disclaims any and all liability associated with the use of firearms in association with its products. While Action Target products are designed to reduce the risks associated with live-fire training, failure to take proper care or to adhere to appropriate safety policies and procedures could result in damage to property or serious injury or death to participants or bystanders. Action Target, Inc. assumes no liability for the improper use of its products or the improper use of firearms or ammunition in conjunction with its products. Every firearms user proceeds at his or her own risk and assumes liability for his or her own actions.
ACTION TARGET • PO BOX 636 • PROVO, UT 84603 • 801-377-8033 •WWW.ACTIONTARGET.COM 12
7. Warranties and Returns
Action Target Inc. LimitedWarranty
Action Target Inc. provides a limitedwarranty on its products.Action Target Inc.will repair or replace products that do not function correctly due to faulty components or workmanship.
The warranty period is in effect for one (1) year from the date of product delivery or project completion and sign off, whichever is later, whether or not actual use of the equipment begins on that date.
Action Target Inc. reserves the right not to provide a warranty for any product that falls into one or more of the following categories:
1.A product modified or altered by anyone other than an authorized Action Target representative.
2.A product damaged or rendered inoperative by failure to perform required maintenance as directed in the individual product operation manual.
3.A product damaged or rendered inoperative due to user negligence or misuse.
4.A product used outside the operational and/or functional scope for which it was intended.
5.A product damaged or rendered inoperative by using ammunition outside the intended scope of the product's design.
6.A product damaged or rendered inoperative through failure to implement recommended protection and/or armoring measures.
7.A product not installed or operated in compliance with the manufacturer?s printed instructions.
8.A product damaged or rendered inoperative due to acts of nature including, but not limited to, lightning, flood, fire, earthquake, etc.
9.A product damaged or rendered inoperative by primary or secondary bullet strikes to or from non-impact surfaces. Examples of non-impact surfaces include, but are not limited to, ceiling baffles, wall baffles, moving target tracks, target trolleys, target stands, target holders, etc.
10.A product damaged or rendered inoperative by inadequate, incorrect, or unstable electricity supply.
11.A product not installed and operated in compliance with applicable building, mechanical, plumbing, and electrical codes.
12.A product damaged or rendered inoperative by exposure to climate and/or environmental conditions that exceed the scope of the product's design.
ActionTarget Inc.'s warranty does not cover the replacement or repair of regular maintenance items including, but not limited to, light bulbs, circuit breakers, batteries, filters, oil, grease, or any other consumable items.
An extended warranty or maintenance package may expand your coverage beyond the conditions stated herein, but does not exist unless explicitly stated in writing as part of a specific designated purchase. Action Target Inc. makes no other warranties, expressed or implied.
The limited warranty provided herein is for repair or replacement only. Action Target Inc. shall not be liable for any loss, cost, damage, or expense of any kind arising out of a breach of the warranty. Action Target Inc.
shall not be liable for any incidental, consequential, exemplary, special, or punitive damages, nor for any loss of revenue, profit or use, arising out of a breach of this warranty or in connectionwith the sale, maintenance, use, operation or repair of any Action Target Inc. product.
Before returning parts for evaluation and/or repair, contact Action Target Inc.'s technical support department for a return authorization (RA) number. Returned items covered by warranty are repaired or replaced and returned to you without charge. Returned items not covered under warranty are subject to repair or replacement charges. Shipping charges for warranty repair or replacement will be paid by Action Target Inc.
Shipping charges for non-warranty repair or replacement will be paid by the customer.
For all warranty assistance or other technical support needs, please contact us at:
Action Target Technical Support 3411 S. Mountain Vista Parkway Provo, UT 84601 877-852-2418 technical-support@actiontarget.com
ACTION TARGET • PO BOX 636 • PROVO, UT 84603 • 801-377-8033 •WWW.ACTIONTARGET.COM 13
ACTION TARGET • PO BOX 636 • PROVO, UT 84603 • 801-377-8033 •WWW.ACTIONTARGET.COM 14
File details come from the government source that posted it. Updated .