This solicitation package is for the VIIS 251144b - Replace Office & Housing Space Impa opportunity with the National Park Service. The agency seeks to replace office and housing space at Lind Point through this project. A pre-proposal conference will be held but has not been scheduled yet, with details to be provided via amendment. Interested parties should monitor for further details on the pre-proposal meeting and respond to solicitation number 140P2021R0109 by the unspecified deadline. The opportunity type is listed as a solicitation to replace specified facilities for the National Park Service.
View the file
Other files for this federal contract opportunity
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE LOCATION
U.S. VIRGIN
ISLANDS
BRITISH VIRGIN
ISLANDS
VIRGIN ISLANDS
NATIONAL PARK
SITE LOCATION
ST. JOHN
VIRGIN ISLANDS
NATIONAL PARK
SITE LOCATION
VISITOR CENTER
CONSTRUCTION DOCUMENTS
A/E FIRM
PRIME/ARCH:
LIOLLIO ARCHITECTURE
CHARLESTON, SC
MEP:
DWG INC.
MOUNT PLEASANT, SC
STRUCTURAL:
4SE
MOUNT PLEASANT, SC
Mark Sheet REVISION Date Initial QUALITY DESIGN CERTIFICATION Prepared in Accordance with Design
Variance from Design Development (Title I)
OR
OR
Development (Title I)
Approved by Superintendent on
Construction Drawing Not Preceded by Design Development (Title I)
Drawing No.
Drawing No.
Project Manager Date
UNITED STATES
DEPARTMENT OF THE INTERIOR
NATIONAL PARK SERVICE
DENVER SERVICE CENTER REGION ISLAND TERRITORY
SOUTHEAST ST JOHNS VIRGIN ISLANDS
LIND POINT ROAD
TITLE OF PROJECT
SHEET
PMIS/PKG NO.
DRAWING NO.
U.S. VIRGIN ISLANDS
ST. JOHN
OF
VIRGIN ISLANDS NATIONAL PARK
VIRGIN ISLANDS NATIONAL PARK
NAME OF PARK
LOCATION WITHIN PARK
251144B
161-160151
CIVIL + LANDSCAPE:
STANTEC
NORTH CHARLESTON, SC
LIND POINT PROJECT
05/17/2021100% COMPLETE CONSTRUCTION DOCUMENTS
REPLACE OFFICE SPACE & HOUSING IMPACTED BY
HURRICANES IRMA AND MARIA - LIND POINT PROJECT
197 357
VOLUME 2Electrical Rev. Added 6/15/2021
VIRGIN ISLANDS NATIONAL PARK
LIND POINT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
DATE:
TECH. REVIEW:
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
CADD:
251144B
160151
:5 :3
A M
C U se rs liz D o c u m e n ts N P S D S C U S V
IIS
R M S V E e m c o rr .r vt
G.
PROJECT INFORMATION &
INDEX - VOL. 2
05/17/2021
CORR
CLARK
CORR
M0. 01 MECHANICAL NOTES & LEGENDS
M0. 02 MECHANICAL SCHEDULES
M0. 03 MECHANICAL DETAILS
M0. 04 MECHANICAL DETAILS
M0. 05 MECHANICAL DETAILS
M1. 01 LOWER LEVEL MECHANICAL PLAN RMS
M1. 02 MAIN LEVEL MECHANICAL PLAN RMS
M1. 03 MAIN LEVEL ENLARGED MECHANICAL PLAN RMS
M1. 04 MECHANICAL ISOMETRIC
M2. 01 MECHANICAL PLAN 2BR
M3. 01 MECHANICAL PLAN 3BR
M4. 01 MECHANICAL PLAN GROUP
MECHANICAL
ELECTRICAL
E0. 01 ELECTRICAL NOTES
E0. 02 ELECTRICAL LEGENDS
E0. 03 ELECTRICAL SCHEDULES
E0. 04 ELECTRICAL DETAILS
E0. 05 ELECTRICAL DETAILS
E0. 06 ELECTRICAL DETAILS
E0. 07 ELECTRICAL DETAILS
E0. 08 ELECTRICAL DETAILS
E0. 09 LIGHTNING PROTECTION PLAN
E0. 10 ELECTRICAL SITE PLANS
E0. 11 MEDIUM VOLTAGE ONE LINE
E0. 12 SYSTEMS RISER DIAGRAMS
E0. 13 SYSTEMS RISER DIAGRAMS
E0. 14 TELE/COM RISER DIAGRAMS
E0. 15 TELE/COM RISER DIAGRAMS
E1. 01 ELECTRICAL RISER DIAGRAM RMS
E1. 02 ELECTRICAL SCHEDULES & DETAILS RMS
E1. 03 ELECTRICAL SCHEDULES & DETAILS RMS
E1. 04 ELECTRICAL SCHEDULES & DETAILS RMS
E1. 05 ELECTRICAL SCHEDULES & DETAILS RMS
E1. 06 LOWER LEVEL POWER & TELECOM PLAN RMS
E1. 07 MAIN LEVEL POWER & TELECOM PLAN RMS
E1. 08 LOWER LEVEL LIGHTING PLAN RMS
E1. 09 MAIN LEVEL LIGHTING PLAN RMS
E1. 10 ROOF POWER PLAN RMS
E1. 11 LOWER LEVEL SYSTEMS PLAN RMS
E1. 12 MAIN LEVEL SYSTEMS PLAN RMS
E1. 13 ENLARGED ELECTRICAL PLANS
E2. 01 ELECTRICAL RISER DIAGRAM 2BR
E2. 02 ELECTRICAL SCHEDULES & DETAILS 2BR
E2. 03 LOWER LEVEL POWER & TELECOM PLAN 2BR
E2. 04 MAIN LEVEL POWER & TELECOM PLAN 2BR
E2. 05 ROOF POWER PLAN 2BR
E2. 06 LOWER LEVEL LIGHTING PLAN 2BR
E2. 07 MAIN LEVEL LIGHTING PLAN 2BR
E2. 08 LOWER LEVEL SYSTEMS PLAN 2BR
E2. 09 MAIN LEVEL SYSTEMS PLAN 2BR
E3. 01 ELECTRICAL RISER DIAGRAM 3BR
E3. 02 ELECTRICAL SCHEDULES & DETAILS 3BR
E3. 03 LOWER LEVEL POWER & TELECOM PLAN 3BR
E3. 04 MAIN LEVEL POWER & TELECOM PLAN 3BR
E3. 05 ROOF POWER PLAN 3BR
E3. 06 LOWER LEVEL LIGHTING PLAN 3BR
E3. 07 MAIN LEVEL LIGHTING PLAN 3BR
E3. 08 LOWER LEVEL SYSTEMS PLAN 3BR
E3. 09 MAIN LEVEL SYSTEMS PLAN 3BR
E4. 01 ELECTRICAL RISER DIAGRAM GROUP
E4. 02 ELECTRICAL SCHEDULES & DETAILS GROUP
E4. 03 ELECTRICAL SCHEDULES & DETAILS GROUP
E4. 04 ELECTRICAL SCHEDULES & DETAILS GROUP
E4. 05 LOWER LEVEL POWER & TELECOM PLAN GROUP
E4. 06 MAIN LEVEL POWER & TELECOM PLAN GROUP
E4. 07 ROOF POWER PLAN GROUP HOUSING
E4. 08 LOWER LEVEL LIGHTING PLAN GROUP
E4. 09 MAIN LEVEL LIGHTING PLAN GROUP
E4. 10 LOWER LEVEL SYSTEMS PLAN GROUP
E4. 11 MAIN LEVEL SYSTEMS PLAN GROUP
PLUMBING
P0. 01 PLUMBING NOTES & LEGENDS
P0. 02 PLUMBING SCHEDULES
P0. 03 PLUMBING DETAILS
P0. 04 PLUMBING DETAILS
P1. 01 LOWER LEVEL DOMESTIC WATER PLAN RMS
P1. 02 MAIN LEVEL DOMESTIC WATER PLAN RMS
P1. 03 LOWER LEVEL SANITARY & VENT PLAN RMS
P1. 04 MAIN LEVEL SANITARY & VENT PLAN RMS
P1. 05 ROOF PLUMBING PLAN RMS
P2. 01 DOMESTIC WATER PLAN 2BR
P2. 02 LOWER LEVEL SANITARY & VENT PLAN 2BR
P2. 03 MAIN LEVEL SANITARY & VENT PLAN 2BR
P2. 04 ROOF PLUMBING PLAN 2BR
P3. 01 DOMESTIC WATER PLAN 3BR
P3. 02 LOWER LEVEL SANITARY & VENT PLAN 3BR
P3. 03 MAIN LEVEL SANITARY & VENT PLAN 3BR
P3. 04 ROOF PLUMBING PLAN 3BR
P4. 01 DOMESTIC WATER PLAN GROUP
P4. 02 LOWER LEVEL SANITARY & VENT PLAN GROUP
P4. 03 MAIN LEVEL SANITARY & VENT PLAN GROUP
P4. 04 ROOF PLUMBING PLAN GROUP
FIRE PROTECTION
FP0. 01 FIRE PROTECTION NOTES & LEGENDS
FP1. 01 MAIN LEVEL FIRE PROTECTION PLAN RMS
FP1. 02 MAIN LEVEL FIRE PROTECTION PLANS RMS
FP2. 01 FIRE PROTECTION PLANS 2BR
FP3. 01 FIRE PROTECTION PLANS 3BR
FP4. 01 FIRE PROTECTION PLANS GROUP
DRAWING INDEX
S0. 01 GENERAL NOTES
S1. 01 RMS (ARCHAEOLOGY) - FOUNDATION PLAN
S1. 02 RMS (ARCHAEOLOGY) - MAIN LEVEL SLAB PLAN
S1. 03 RMS (ARCHAEOLOGY) - ROOF FRAMING PLAN
S1. 04 SITE RETAINING WALL DETAIL
S1. 05 RMS (STORAGE) - FOUNDATION PLAN
S1. 06 RMS (STORAGE) - FIRST FLOOR SLAB PLAN
S1. 07 RMS (STORAGE) - ROOF FRAMING PLAN
S1. 08 RMS (ADMIN) - FOUNDATION PLAN
S1. 09 RMS (ADMIN) - LOWER LEVEL SLAB PLAN
S1. 10 RMS (ADMIN) - MAIN LEVEL SLAB PLAN
S1. 11 RMS (ADMIN) - ROOF FRAMING PLAN
S1. 12 RMS (ADMIN) - CLERESTORY FRAMING PLAN
S1. 13 RMS MECHANICAL YARD FOUNDATION PLAN
S1. 14 RMS MECHANICAL YARD SLAB & STAIR PLANS
S1. 15 RMS - WALL & FOUNDATION DETAILS
S1. 16 RMS - FOUNDATION - SLAB DETAILS
S1. 17 RMS - FOUNDATION - SLAB DETAILS
S1. 18 RMS - FOUNDATION-SLAB DETAILS
S1. 19 RMS - FOUNDATION -SLAB DETAILS
S1. 20 RMS - FOUNDATION DETAILS
S1. 21 RMS - SLAB DETAILS
S1. 22 RMS - FOUNDATION -SLAB DETAILS
S1. 23 RMS - SLAB DETAILS
S1. 24 RMS - SLAB DETAILS
S1. 25 RMS - SLAB DETAILS
S1. 26 RMS MECHANICAL YARD SECTIONS
S1. 27 RMS MECHANICAL YARD SECTIONS
S1. 28 RMS MECHANICAL YARD SECTIONS
S1. 29 RMS - ROOF FRAMING DETAILS
S1. 30 RMS - ROOF FRAMING DETAILS
S1. 31 RMS - ROOF FRAMING DETAILS
S1. 32 RMS - ROOF FRAMING DETAILS
S1. 33 RMS - ROOF FRAMING DETAILS
S1. 34 RMS - ROOF FRAMING DETAILS
S1. 35 RMS - ROOF FRAMING DETAILS
S1. 36 RMS - ROOF FRAMING DETAILS
S1. 37 RMS - ROOF FRAMING DETAILS
S2. 01 2BR - FOUNDATION PLAN
S2. 02 2BR - GROUND FLOOR SLAB PLAN
S2. 03 2BR - FIRST FLOOR SLAB PLAN
S2. 04 2BR - ROOF FRAMING PLAN
S2. 05 FOUNDATION DETAILS
S2. 06 FOUNDATION DETAILS
S2. 07 FOUNDATION/SLAB DETAILS
S2. 08 SLAB DETAILS
S2. 09 SLAB DETAILS
S2. 10 SLAB DETAILS
S2. 11 SLAB DETAILS
S2. 12 ROOF FRAMING DETAILS
S2. 13 ROOF FRAMING DETAILS
S2. 14 BREEZE BLOCK WALL DETAILS
S3. 01 3BR - FOUNDATION PLAN
S3. 02 3BR - GROUND FLOOR SLAB PLAN
S3. 03 3BR - FIRST FLOOR SLAB PLAN
S3. 04 3BR - ROOF FRAMING PLAN
S4. 01 GROUP - FOUNDATION PLAN
S4. 02 GROUP - GROUND FLOOR SLAB PLAN
S4. 03 GROUP - FIRST FLOOR SLAB PLAN
S4. 04 GROUP - ROOF FRAMING PLAN
S5. 01 MASONRY DETAILS
S5. 02 MASONRY DETAILS
STRUCTURAL
DESIGN CRITERIA:
CODES: IBC 2018/ ASCE 7-16
LIVE LOAD: ROOF..........................................................20 psf
FLOORS:
RESIDENCES..........................................40 psf RMS (TYPICAL).......................................80 psf RMS (ARCHIVES & COLLECTIONS).....125 psf
WIND LOAD: ASCE 7-16
RISK CATEGORY II
180 mph (SEA LEVEL)
210 MPH (W/ TOPOGRAPHIC FACTOR FROM FEMA P.2021)
EXPOSURE D
ENCLOSURE CLASSIFICATION: ENCLOSED
INTERNAL PRESSURE COEFFICIENT = ±0.18
COMPONENTS AND CLADDING PRESSURES:
ULTIMATE ASD
WALLS: TYPICAL......................... +112 psf/ -122 psf +67 psf/ -73 psf CORNERS...................... +112 psf/ -137 psf +67 psf/ -82 psf
ROOF (HOUSING): ZONE 1........................... +44 psf/ -131 psf +27 psf/ -79 psf (REF. ASCE 7-16 ZONE 2........................... +44 psf/ -144 psf +27 psf/ -86 psf FIGURE 30.3-5A) ZONE 2'.......................... +44 psf/ -176 psf +27 psf/ -105 psf
ZONE 3........................... +44 psf/ -159 psf +27 psf/ -95 psf ZONE 3'.......................... +44 psf/ -142 psf +27 psf/ -128 psf
ROOF (RMS): ZONE 1'.......................... +39 psf/ -111 psf +23.4 psf/ -66.6 psf (REF. ASCE 7-16 ZONE 1........................... +39 psf/ -162.5 psf +23.4 psf/ -97.5 psf FIGURE 30.3-2A) ZONE 2........................... +39 psf/ -214 psf +23.4 psf/ -128 psf
ZONE 3........................... +39 psf/ -265 psf +23.4 psf/ -159 psf
SEISMIC LOAD: IBC 2018/ ASCE 7-16
Sds = 0.996 Sd1 = 0.433
SEISMIC OCCUPANCY CATEGORY II
SITE CLASS C
IMPORTANCE FACTOR = 1.00
LATERAL FORCE RESISTING SYSTEM: SPECIAL REINFORCED MASONRY SHEAR WALLS
SEISMIC DESIGN CATEGORY D
ANALYSIS PROCEDURE - EQUIVALENT LATERAL FORCE PROCEDURE
FOUNDATIONS, WALLS, STRUCTURAL GROUND FLOOR SLABS ON GRADE & ELEVATED SLABS:
1. REFER TO GEOTECHNICAL REPORT AND ADDENDUMS BY JACA & SIERRA TESTING LABORATORIES, AND SPECIFICATIONS FOR REQUIREMENTS FOR SUBGRADE PREPARATION, PRIOR TO INSTALLATION OF
FOUNDATIONS AND SLABS.
2. FOUNDATIONS DESIGNED USING AN ALLOWABLE BEARING CAPACITY OF 2500 psf. FOUNDATIONS ARE TO BEAR ON WEATHERED ROCK. SEE EARTHWORK SPECS. & GEOTECHNICAL REPORT & ADDENDUM 3 FOR REQUIREMENTS. AT LOCATIONS WHERE WEATHERED ROCK IS ENCOUNTERED AT THE SUBGRADE LEVEL, EXCAVATE DOWN TO FOUNDATION BEARING LEVELS. FOUNDATIONS TO BEAR ON WEATHERED ROCK.
3. WHERE CONDITIONS REQUIRE THAT BUILDINGS LIE OVER & MUST BEAR ON BOTH WEATHERED ROCK AND NEW FILL, ADDENDUM 3 OF THE GEOTECHNICAL REPORT REQUIRES THAT THERE BE A MINIMUM 2 FOOT LAYER OF NEW FILL MATERIAL BENEATH ALL FOOTINGS. THIS MAY REQUIRE ADDITIONAL
EXCAVATION OF WEATHERED ROCK. PROVIDE UNIT PRICES FOR ADDITIONAL EXCAVATION AND
ADDITIONAL COMPACTED FILL. SEE SPECIFICATIONS.
4. SINCE EXCAVATIONS THROUGH WEATHERED ROCK ARE PLANNED, HYDRAULIC FRACTURING EQUIPMENT MAY BECOME NECESSARY. THE CONTRACTOR SHOULD HAVE KNOWLEDGE, SUITABLE EQUIPMENT AND
PREVIOUS EXPERIENCE DEALING WITH THIS TYPE OF ROCK FORMATION.
5. PROVIDE 4 INCHES OF COMPACTED CLEAN SAND OR GRAVEL BENEATH ALL SLABS ON GRADE. SEE
GEOTECHNICAL REPORT. PROVIDE VAPOR BARRIER BENEATH SLABS ON GRADE. SEE CONCRETE
SPECIFICATIONS.
6. CONCRETE FOR FOUNDATIONS, WALLS, STRUCTURAL SLABS ON GRADE AND ELEVATED SLABS SHALL HAVE A MINIMUM 28- DAY COMPRESSIVE STRENGTH OF 4000 psi, SHALL BE NORMAL WEIGHT & SHALL
HAVE A MAXIMUM WATER TO CEMENT RATIO OF 0.45. CONCRETE CONSTRUCTION SHALL BE IN
ACCORDANCE WITH THE REQUIREMENTS OF ACI 301. SUBMIT PROPOSED MIX DESIGNS FOR APPROVAL
PRIOR TO CASTING FOUNDATIONS AND OTHER CONCRETE WORK.
7. CONCRETE FOR WALLS AND SLABS OF CISTERNS SHALL CONTAIN AN INTEGRATED CEMENTITIOUS
CRYSTALLINE WATERPROOF ADMIXTURE TO MAKE CONCRETE IMPERMEABLE TO WATER. SEE
SPECIFICATIONS.
8. FOUNDATIONS, INCLUDING FOOTINGS, AND THICKENED SLAB FOUNDATIONS, SHALL BE SIDE FORMED.
9. AT CONSTRUCTION JOINTS FOR FOUNDATIONS, ALL REINFORCEMENT SHALL EXTEND THROUGH JOINT TO MEET SPLICE LENGTH REQUIREMENTS. PROVIDE SHEAR KEY AND ROUGHENED SURFACE. GC SHALL SUBMIT PLACING PLAN SHOWING PROPOSED JOINT LOCATIONS FOR REVIEW PRIOR TO CONSTRUCTION.
SEE SPECIFICATIONS.
10. CONSTRUCTION & CONTRACTION JOINTS IN CONCRETE WALLS SHALL BE LOCATED TO ALIGN W/ STUCCO JOINTS. JOINT LOCATIONS ARE SHOWN ON PLANS. COORDINATE W/ ARCHITECTURAL DRAWINGS. GC SHALL SUBMIT A PLACING PLAN SHOWING JOINT LOCATIONS FOR REVIEW PRIOR TO CONSTRUCTION.
SEE SPECIFICATIONS.
11. CONSTRUCTION JOINTS IN CONCRETE SLABS & BEAMS SHALL BE LOCATED IN THE MIDDLE THIRD OF THE SLAB OR BEAM SPAN. GC SHALL SUBMIT A CONCRETE PLACING PLAN SHOWING PROPOSED LOCATIONS
OF JOINTS FOR REVIEW PRIOR TO CONSTRUCTION. SEE SPECIFICATIONS.
12. CONTROL JOINTS FOR TYPICAL SLABS ON GRADE SHALL BE FORMED BY SAW CUTTING 1/8" WIDE x 1/3 DEPTH OF SLAB AT LOCATIONS SHOWN. CONTROL JOINTS SHALL BE CUT AS SOON AFTER FINISHING
SLAB AS POSSIBLE WITHOUT DISLODGING THE AGGREGATE.
13. JOINTS IN SLABS ON GRADE AT CISTERN TO BE DETAILED AS SHOWN ON DRAWINGS. GC TO SUBMIT CONCRETE PLACING PLAN SHOWING LOCATIONS OF PROPOSED JOINTS PRIOR TO CONSTRUCTION, SEE
SPECIFICATIONS.
FOUNDATIONS, WALLS, STRUCTURAL GROUND FLOOR SLABS ON GRADE & ELEVATED SLABS (cont.):
14. SOME DETAILS ARE SHOWN W/ AN ASSUMED PLACING SEQUENCE. GC MAY CHOOSE TO ALTER THE PLACING SEQUENCE TO FACILITATE THE WORK & MAY NEED TO ALTER THE DETAILS AS DRAWN. IN THOSE CASES, GC TO SUBMIT ALTERNATE PLACING SEQUENCE & PROPOSED DETAILS FOR REVIEW
PRIOR TO CONSTRUCTION.
15. REINFORCING SHALL COMPLY WITH ASTM SPECIFICATION A615, GRADE 60. FOUNDATION REINFORCING SHALL EXTEND TO WITHIN 3 INCHES OF FAR FACE OF INTERSECTING FOUNDATION. ALL TOP BARS IN STRUCTURAL GROUND FLOOR SLABS AND TOP BARS IN FOUNDATIONS SHALL TERMINATE IN A STANDARD
90 DEGREE HOOK.
16. SPLICE LENGTHS FOR REINFORCING SHALL BE AS FOLLOWS:
HORIZONTAL BARS VERTICAL BARS
#4 BARS.......2'-0" #5 BARS.......2'-0"
#5 BARS.......2'-6" #6 BARS.......2'-7"
#6 BARS.......3'-4" #7 BARS.......3'-6"
#7 BARS.......4'-0"
17. WITH THE EXCEPTION OF OPENINGS NOTED IN NOTE 17, ALL OPENINGS IN FLOOR SLABS & WALLS SHALL
BE FORMED IN WHEN THE CONCRETE ELEMENTS ARE CAST OR MASONRY ELEMENTS ARE BUILT.
OPENINGS SHALL NOT BE DRILLED OR CUT. MOST OPENINGS ARE NOT SHOWN IN STRUCTURAL DRAWINGS.
COORDINATE OPENING LOCATIONS & SIZES W/ ARCHITECTURAL & MEP DRAWINGS. SEE DETAILS SHEETS S2.08, S5.01, & S5.02 FOR SPECIAL OPENING REINFORCING REQUIREMENTS. GC SHALL SUBMIT SLAB PLANS & WALL ELEVATIONS SHOWING WALL OPENING LOCATIONS & SIZES, W/ ADDITIONAL REINFORCING FOR
REVIEW PRIOR TO CONSTRUCTION.
18. ROUND OPENINGS IN WALLS OR SLABS THAT ARE LESS THAN 4" DIAMETER & LOCATED MORE THAN 16" ON CENTER MAY BE FIELD DRILLED. TAKE REQUIRED PRECAUTIONS TO AVOID CUTTING REINFORCING.
DRILLED OPENINGS SHALL BE SHOWN ON PLANS & WALL ELEVATIONS REQUIRED BY NOTE 16.
STEEL:
1. STRUCTURAL STEEL WIDE FLANGE SECTIONS, AND BASE PLATES FOR COLUMNS SHALL COMPLY WITH
ASTM SPECIFICATION A992 OR A572, GRADE 50.
2. ALL OTHER STRUCTURAL STEEL SHAPES AND PLATES SHALL COMPLY WITH ASTM SPECIFICATION A36, UNLESS NOTED OTHERWISE.
3. COLD FORM STRUCTURAL STEEL TUBE SHAPES SHALL COMPLY WITH ASTM SPECIFICATION A500, GRADE B.
4. WELDING SHALL COMPLY WITH AWS CODE D1.1 AND SHALL BE PERFORMED BY CERTIFIED
WELDERS.
5. STRUCTURAL STEEL FRAMING AND BOLTS FOR RMS BUILDINGS SHALL BE HOT-DIP GALVANIZED.
GALVANIZING SHALL BE NON-QUENCHED TO ALLOW FOR PAINT ADHESION.
6. ANCHOR BOLTS (RODS) FOR COLUMNS SHALL BE PROVIDED WITH A NUT AND WASHER AT THE EMBEDDED END AND SHALL CONFORM TO ASTM SPECIFICATION F1554. RODS SHALL BE WELDABLE AND SHALL BE
GALVANIZED. SEE BASE PLATE DETAILS FOR GRADES.
7. BOLTS FOR STEEL TO STEEL CONNECTIONS SHALL CONFORM TO ASTM SPECIFICATION A325 AND SHALL BE GALVANIZED. FOR TYPICAL CONNECTIONS, TYPE N BOLTS (ASTM A325) IN BEARING TYPE CONNECTIONS TIGHTENED TO MEET SNUG TIGHT REQUIREMENTS PER AISC MANUAL OF STEEL CONSTRUCTION SHALL BE
USED.
8. FRAME OPENINGS AT ROOF LEVEL FRAMING NOT DETAILED ELSEWHERE, AND ALL OPENINGS GREATER THAN 12" x 12", WITH L3 1/2 x 3 1/2 x 5/16 AT ALL FOUR SIDES OF OPENING. AT MECHANICAL OR OTHER EQUIPMENT SUPPORTS NOT DETAILED ELSEWHERE, PROVIDE L3 1/2 x 3 1/2 x 5/16 BENEATH ALL UNIT CURBS, SUPPORTS FOR PV SYSTEM, AND AT ALL EDGES OF OPENINGS FOR DUCTWORK. CONNECT ANGLES TO EACH OTHER AND TO STEEL FRAMING WITH A MINIMUM OF 4 INCHES OF 3/16 INCH FILLET WELD.
10. TYPICAL FLOOR DECK FOR ROOF OF RMS STORAGE BUILDING SHALL BE GALVANIZED COMPOSITE DECK, WITH A 1 1/2 INCH x 6 INCH CORRUGATION PATTERN, 18 GAGE, AND SHALL HAVE THE FOLLOWING MINIMUM
SECTION PROPERTIES:
S = 0.311 in3/ft.
I = 0.272 in4/ft.
DECK SHALL BE CONTINUOUS OVER THREE SPANS MINIMUM, AND SHALL BE ATTACHED AT EACH SUPPORT AT EACH FLUTE WITH No.12 SCREWS, TO SUPPORTS AT EDGES OF FLOOR PARALLEL TO DECK SPAN WITH No. 12 SCREWS AT 4 INCHES ON CENTER, AND AT SIDELAPS WITH 7 No. 10 SCREWS PER SPAN OF DECK
BETWEEN SUPPORTS.
11. ROOF DECK FOR REMAINDER OF RMS BUILDINGS SHALL BE GALVANIZED, WITH A 1 1/2 INCH x 6 INCH CORRUGATION PATTERN, 18 GAGE, TYPE B, AND SHALL HAVE THE FOLLOWING MINIMUM SECTION
PROPERTIES:
S = 0.289 in3/ft.
I = 0.318 in4/ft.
DECK SHALL BE CONTINUOUS OVER THREE SPANS MINIMUM, WHERE POSSIBLE, AND SHALL BE ATTACHED AT EACH SUPPORT AT EACH FLUTE WITH 2-No. 12 SCREWS, TO SUPPORTS AT EDGES OF ROOF PARALLEL TO DECK SPAN WITH No. 12 SCREWS AT 4 INCHES ON CENTER, AND AT SIDELAPS WITH 8 No. 10 SCREWS
PER SPAN OF DECK BETWEEN SUPPORTS.
12. CONCRETE FOR COMPOSITE ELEVATED SLABS AT RMS STORAGE BUILDING SHALL BE NORMAL WEIGHT CONCRETE AND SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 4000 psi.
13. BRACED FRAMES SHOWN ARE PART OF THE SEISMIC LATERAL LOAD RESISTING SYSTEM AND AS SUCH MUST BE DETAILED, WELDED, AND INSPECTED PER THE REQUIREMENTS OF AISC 341. BRACED FRAMES
ARE CATEGORIZED AS ORDINARY BRACED FRAMES (OBF).
14. MISCELLANEOUS STEEL ANGLES, PLATES, ETC., REQUIRED FOR SUPPORT AT EDGES OF ROOF, SOFFITS
AND FASCIAS, AND OTHER ARCHITECTURAL ITEMS MAY NOT BE SHOWN ON THE STRUCTURAL
DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR REQUIRED ITEMS, THEIR CONNECTIONS, AND
ASSOCIATED DETAILING.
GENERAL NOTES
STEEL (cont.):
15. ALL METAL STUDS, CONNECTIONS, LINTELS, BRIDGING, BRACING, AND THE METAL STUD SYSTEM AS A WHOLE SHALL BE DESIGNED BY THE METAL STUD DESIGNER FOR APPLICABLE LATERAL LOADS AND VERTICAL LOADS AS LISTED UNDER "DESIGN CRITERIA" ON THIS SHEET AND AS DISCUSSED IN THE SPECIFICATIONS. METAL
STUD SIZES AND SPACINGS SHALL BE AS SHOWN IN THE ARCHITECTURAL DRAWINGS.
16. WHERE ADHESIVE ANCHORS ARE REFERRED TO ON THE DRAWING, ANCHORS ARE SPECIFIED AT LOCATIONS ARE ANCHORING TO EITHER CONCRETE OR MASONRY CONSTRUCTION. ALL ANCHORS TO BE INSTALLED
PER MANUFACTURER'S INSTRUCTIONS AND SHALL BE GALVANIZED.
ACCEPTABLE MANUFACTURERS INCLUDE:
- HILTI
- SIMPSON STRONG-TIE
- DEWALT
A) AT LOCATIONS WHERE ANCHORS ARE ANCHORING TO MASONRY CONSTRUCTION, ANCHORS SHALL BE APPROVED FOR USE IN GROUTED OR UNGROUTED MASONRY AND SHALL BE CAPABLE OF DEVELOPING A MINIMUM ASD SHEAR CAPACITY OF 1800 lbs. AND A MINIMUM ASD TENSION CAPACITY OF 1600 lbs.
B) AT LOCATIONS WHERE ANCHORS ARE ANCHORING TO CONCRETE CONSTRUCTION, ANCHORS SHALL BE APPROVED FOR USE IN CRACKED CONCRETE AND SHALL BE CAPABLE OF DEVELOPING A MINIMUM ULTIMATE SHEAR CAPACITY OF 20 kips AND AN ULTIMATE TENSION CAPACITY OF 9.3 kips FOR 5/8 INCH DIA. ANCHORS, AND A MINIMUM ULTIMATE SHEAR CAPACITY OF 6.8 kips AND AN ULTIMATE TENSION CAPACITY OF 3.2 kips FOR 1/2 INCH DIA. ANCHORS.
17. WHERE DOWELS ARE SHOWN BEING ANCHORED TO EXISTING CONCRETE CONSTRUCTION WITH CONCRETE EPOXY, EPOXY SHALL BE SPECIFICALLY DESIGNED FOR ANCHORING RODS TO CONCRETE. EPOXY SHALL BE CAPABLE OF DEVELOPING A MINIMUM ULTIMATE TENSION OF 11 kips. INSTALL PER MANUFACTURER'S
REQUIREMENTS.
ACCEPTABLE MANUFACTURERS INCLUDE:
- HILTI
- SIMPSON STRONG-TIE
- DEWALT
18. STRUCTURAL STEEL PLATES, ANGLES, BOLTS, AND EPOXY ANCHORS FOR WOOD FRAMED ROOFS AT THE HOUSING BUILDINGS SHALL BE STAINLESS STEEL. STAINLESS STEEL PLATES AND ANGLES SHALL COMPLY WITH ASTM SPECIFICATION A304. STAINLESS STEEL FOR BOLTS AND ANCHORS SHALL COMPLY WITH ASTM
SPECIFICATION A316.
REINFORCED MASONRY
1. ALL REINFORCED MASONRY SHALL HAVE A MINIMUM f'm = 1500 PSI.
2. GROUT FOR FILLED CORES, BOND BEAMS, AND LINTELS SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI AND AN 8" SLUMP. MORTAR SHALL NOT BE USED AS A SUBSTITUTE FOR GROUT.
3. MASONRY CONSTRUCTION SHALL COMPLY WITH THE REQUIREMENTS OF ACI 530.
4. PROVIDE STANDARD WEIGHT HOT-DIP GALVANIZED HORIZONTAL JOINT REINFORCING AT 16 INCHES ON
CENTER IN ALL CMU WALLS.
5. MORTAR SHALL BE TYPE S, AND SHALL BE MADE USING MORTAR CEMENT OR PORTLAND CEMENT/LIME MIX.
MASONRY CEMENT SHALL NOT BE USED FOR REINFORCED MASONRY CONSTRUCTION.
6. PROVIDE BOND BEAMS WITH 2-#6 BARS, CONTINUOUS, AT 4'-0"(+/-) ON CENTER VERTICALLY IN ALL 12" MASONRY WALLS. PROVIDE BOND BEAMS WITH 2-#5 BARS, CONTINUOUS, AT 4'-0"(+/-) ON CENTER VERTICALLY
IN 8" MASONRY WALLS. SEE SHEET S601 FOR ADDITIONAL REQUIREMENTS.
7. VERTICAL REINFORCING IN SINGLE REINFORCED WALLS SHALL BE CENTERED IN THE WALL. REINFORCING BAR POSITIONERS SHALL BE USED IN ALL WALLS TO ENSURE THAT VERTICAL REINFORCING IS LOCATED AS
REQUIRED.
8. SEE SHEETS S5.01 & S5.02 FOR LINTEL REQUIREMENTS AT MASONRY WALLS. LINTELS ARE REQUIRED AT ALL MASONRY OPENINGS, INCLUDING MECHANICAL DUCTWORK PENETRATIONS THROUGH WALLS. COORDINATE DUCTWORK PENETRATION OPENING LOCATIONS AND ELEVATIONS FROM MECHANICAL DRAWINGS WITH LINTEL REQUIREMENTS PRIOR TO CONSTRUCTION OF CMU WALLS. LINTELS SHOWN SHALL BE PROVIDED
UNLESS COORDINATION CONFLICTS ARE DISCOVERED AND REDESIGNS ARE PROVIDED BY
ARCHITECT/ENGINEER PRIOR TO CONSTRUCTION OF CMU WALLS.
9. SEE SHEETS S5.01 & S5.02 FOR COMPLETE MASONRY WALL CONSTRUCTION REQUIREMENTS.
WOOD
1. STRUCTURAL WOOD FRAMING FOR 2x FRAMING AND ALL DECKING SHALL BE No. 1
SOUTHERN YELLOW PINE. ALL MEMBERS SHALL BE PRESSURE TREATED.
2. STRUCTURAL WOOD HEAVY TIMBER FRAMING (3 x 8 AND LARGER) SHALL BE No. 1
SOUTHERN PINE. ALL MEMBERS SHALL BE PRESSURE TREATED.
3. SCREW 5/8" PLYWOOD ROOF SHEATHING TO DECKING WITH No. 10 SCREWS
SPACED @ 4"O.C. AT PERIMETER OF SHEETS AND 6"O.C. AT INTERIOR OF
SHEETS. SCREWS SHALL NOT EXTEND THRU DECKING.
4. ALL NAILS AND SCREWS SHALL BE STAINLESS STEEL.
SPECIAL INSPECTIONS
1. SEE SPECIFICATION SECTION 01 4000 FOR SPECIAL INSPECTION REQUIREMENTS
VIRGIN ISLANDS NATIONAL PARK
LIND POINT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
DATE
TECH. REVIEW:
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
CADD:
251144B
160151S0.
GENERAL NOTES
11/04/2020
LGC & TGM
DWU
188 345
DWU
8 10 13 14 17
A
F
H
K
FTG. 2
FT
G
. 2
FT
G
. 2
FT
G
. 1
FTG. 2
FT
G . 1
FT
G
. 1
FT
G
. 2
14'-7 3/16" 10'-0 3/4"
T/FTG EL. = -11'-0"
T/FTG EL. = -8'-4"
T/FTG EL. = -6'-0"
C
E
G
FTG. 2
FTG. 2
FT
G
. 1
12" CMU WALLS,
SEE NOTE 3, TYP.
COLUMN C2,
SEE NOTE 5
FTG. 3
COLUMN
C1, SEE
NOTE 4
12" WIDE x 18"
DEEP TIE BEAM.
TIE BEAM SLOPES
(TYP.) SEE NOTE 6
12" CMU WALLS,
TYP. SEE NOTE 3
T/FTG EL. = -12'-8"
FTG. 3FTG. 3
FT
G
. 6
FT
G . 6
12" CMU
RETAINING WALL,
SEE NOTE 7
T/FTG EL. = -8'-4"
T/FTG
T/FTG EL. = -8'-4"
T/FTG EL. = -11'-0"
T/FTG EL. = -11'-0"
T/FTG EL. = -8'-4"
T/FTG EL. = -6'-0"
T/FTG EL. = -6'-0"
TURN DOWN FTG.
ON TOP OF LOWER
FTG.
T/FTG EL. = -8'-4"
STORAGE BUILDING
WALLS & FOUNDATIONS.
SEE SHEET S1.05
FTG. 4
STEPPED FTG. (TYP.
WHERE SHOWN)
T/FTG EL. = -8'-4"
STEPPED FTG.
(TYP. WHERE
SHOWN)
4' -0
'-8
/4
4' -0
/1 6"
'-4
1/
'-1
3/
8" 9'
-1
5/ 8"
1'-1 9/16" 13'-5 5/8"
12" CMU
WALL &
FTG.
CONCRETE
COLUMN C2.
SEE NOTE 5
'-6
1/
'-9
/8
CONCRETE
COLUMN C2.
SEE NOTE 5
FT
G
. 4
/1 6"
1' -3
/8
" FTG. 2
1' -1
7/
8"
T/FTG EL. = -6'-0"
FTG. 2
ADMIN.
BUILDING
WALLS & FND.
SEE SHEET
S1.08
T/FTG
EL. = -12'-8"
M
AT
C H
L
IN
E
SE
E S1
. 0
M
AT
C H
L
IN
E
SE
E S1
. 0
MATCH LINE SEE S1. 05
MATCH LINE SEE S1. 05
MATCH LINE SEE S1. 05
MATCH LINE SEE S1. 05
T/FTG EL. = -8'-4"
T/FTG EL. = -8'-4"
T/FTG EL. = -8'-4"
T/FTG EL. = -11'-0"
SEE SHEET S1.04 FOR RETAINING
WALL & FOUNDATION
REQUIREMENTS BEYOND AREA
SHOWN. SEE CIVIL DWGS. FOR
LOCATIONS & GRADED
DIFFERENCES
12" CMU
RETAINING
WALL, SEE
SHEET S1.04
RETAINING WALL
FOUNDATION,
SEE SHEET S1.04
FT
G
. 2
RETAINING WALL
FOUNDATION,
SEE SHEET S1.04
'-8
/8
'-1
7/ 8"
9' -2
/8
4'
-1
1/ 2"
12" CMU
CONCRETE
WALL
COLUMN
12" CMU
WALL
T/FTG EL. = -6'-0"T/FTG EL. = -8'-4"
S1. 16
18'-4 3/8"
COLUMN &
12" CMU WALL
COLUMN &
12" CMU WALL
12" CMU
WALL
COLUMN C2
12" CMU WALL
& FOOTING
23'-8 3/8" 16'-3 5/8" 18'-4 3/8"
1'-11" 2" 15'-2 3/16" 3'-0 3/16" 1'-0"
S1. 16 1
S1. 16
S1. 16
S1. 16
S1. 16
S1. 16
12'-4 1/4"
12" CMU RETAINING
WALL, SEE NOTE 7
/1 6"
FT
G
. 8
EL. = -11'-0"
4'
-1
5/ 8"
FT
G
. 3
11'-8 3/16" 2"
CONCRETE
COLUMN C3.
SEE NOTE 9
FT
G
. 4
FTG. 4
T/FTG EL. = -6'-0"
FTG. 8
8" CMU FOR SUPPORT OF STONE
VENEER. SEE NOTE 10.
8" CMU FOR SUPPORT
OF STONE VENEER.
SEE NOTE 10.
/1
6" 16" SQUARE CMU PIER.
REINFORCE W/ 4-#5 VERT.
TYP. WHERE SHOWN.
8" x 16" CMU PIER.
REINFORCE W/ 4-#
5 VERT. TYP.
WHERE SHOWN.
12" WIDE x 18" DEEP TIE
BEAM. TIE BEAM SLOPES
(TYP.) SEE NOTE 6
ADMINISTRATIVE
BUILDING
CONF &
ARCHAEOLOGY
BUILDING
STORAGE BUILDING
KEY PLAN
AREA
VIRGIN ISLANDS NATIONAL PARK
LIND POINT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
DATE
TECH. REVIEW:
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
CADD:
251144B
160151S1.
RMS (ARCHAEOLOGY) -
FOUNDATION PLAN
11/04/2020
LGC & TGM
DWU
189 345
DWU
1/4" = 1'-0" Foundation Plan - Archaeology
NOTES:
1. DIMENSIONS SHOWN ARE TO CENTERLINE OF 12" CMU WALL OR COLUMN & FOOTING, TYPICAL U.N.O.
2. SEE TYPICAL SECTION THROUGH FOOTING & FOOTING SCHEDULE, SHEET S1.15, FOR FOOTING REQUIREMENTS.
3. 12" CMU WALLS TO BE REINFORCED W/ #6 VERTICALS @ 16"O.C. (FOUNDATION TO FIRST FLOOR) & #6 VERTICALS @ 24"O.C.
(FIRST FLOOR TO ROOF). SEE SHEETS S5.01 & S5.02 FOR TYPICAL WALL REINFORCING DETAILS. EXTEND LOWER LEVEL
VERTICAL BARS A MINIMUM OF 3'-0" ABOVE LEVEL 1 SLAB.
4. CONCRETE COLUMNS C1 ARE 12" WIDE x 18" LG & EXTEND FROM FOUNDATION TO ROOF LEVEL. REINFORCE W/
6-#7 VERT. & #3 TIES @ 6" O.C.
5. CONCRETE COLUMNS C2 ARE 12" x 12" & EXTEND TO EXTERIOR SLAB LEVEL. REINFORCE W/ 4-#6 VERT. & #3 TIES @ 6" O.C.
6. REINFORCE 12"x18" TIE BEAM W/ 2-#6 TOP & BOTTOM & #3 STIRRUPS @ 12" O.C.
7. 12" CMU RETAINING WALL TO EXTEND FROM FOUNDATION TO FIRST FLOOR SLAB LEVEL. REINFORCE W/ #6 VERT. @ 16"O.C.
8. SEE ARCH. DWGS. A1.20 & A1.31 (ELEVATION) FOR CRAWL SPACE VENT LOCATIONS & ACCESS DOOR.
9. CONCRETE COLUMN C3 TO BE 11 5/8" x 17 5/8" AND TO BE REINFORCED W/ 4-#6 VERT. & #3 TIES @ 6"O.C.
10. STONE VENEER SHOWN. STONE TO BE SUPPORTED ON 8" CMU AT LOCATIONS WITHOUT SLAB. PROVIDE 8 INCH CMU UP TO
12 INCHES BELOW GRADE SUPPORT OF STONE VENEER. REINFORCE 8 INCH CMU WITH #5 VERT. @ 24"O.C. GROUT ALL CELLS SOLID. COORDINATE EXTENTS OF STONE VENEER UNDER BASE BID W/ ARCHITECTURAL DRAWINGS.
0 2 4 8
SCALE: 1/4" = 1'-0"
H
K
S1. 16
12" x 18" CONC. COLUMN
C1, BELOW. SEE NOTE 4.
12" CMU WALLS.
SEE NOTE 1.
24" x 24" CONCRETE
BEAM. SEE NOTE 3.
C
E
8" CONCRETE SLAB.
T/SLAB EL. = 0'-0"
SEE NOTE 2
12" CMU WALL BELOW.
SEE NOTE 1
12" CMU WALL
BELOW.
SEE NOTE 1
12" CMU
WALL BELOW
12" CMU
WALL BELOW
1'-1 9/16" 13'-5 5/8"
12" x 12" CONC. COLUMNS
C2 (BELOW). SEE NOTE 11
12" x 20" CONC. BEAMS.
SEE NOTE 8
8" MIN. CONC.
SLAB
T/SLAB EL. =
VARIES
SEE NOTE 6
12" x 12" CONC.
COLUMN (C2),
TYP. WHERE
SHOWN. SEE
NOTE 9
12" CMU RETAINING
WALL. SEE NOTE 7
12" x 20" CONC.
BEAM. SEE NOTE 8
1 3/4"
EXP.
JOINT 24" x 24"
CONC. BEAM.
SEE NOTE 10
12" x 16"
CONCRETE
BEAM
CONC.SLAB
T/SLAB EL. VARIES
SEE NOTE 6
14'-7 3/16" 10'-0 3/4" 23'-8 3/8" 16'-3 5/8" 18'-4 3/8" 12'-4 1/4"
9' -1
5/
8"
24" x 24" CONC.
BEAM. SEE
NOTE 10
12" x 12" CONC.
COLUMN (C2),
SEE NOTE 10
1' -3
/8
S1. 19
S1. 16
SEE RMS STORAGE BUILDING FIRST
FLOOR SLAB PLAN FOR
REQUIREMENTS, THIS AREA
S1. 17
S1. 16
M
AT
C H
L
IN
E
SE
E S1
. 1
M
AT
C H
L
IN
E
SE
E S1
. 1
MATCH LINE SEE S1. 06
MATCH LINE SEE S1. 06
S1. 18
JOINT
1 3/4" EXP.
12" CMU RETAINING
WALL, SEE DETAIL
SHEET S1.04
12" CMU
RETAINING
WALL BELOW,
SEE NOTE 7
12" CMU WALL
BELOW, SEE
NOTE 1
T/SLAB EL. AT
EDGE = -0'-2 1/2" (±)
12" CMU WALL 12" CMU WALLS & CONC.
COLUMNS 12" CMU
WALL
T/SLAB EL. = 0'-1"
SLOPES
T/SLAB EL. = -0'-1"
S1. 19
S1. 18
T/SLAB EL. = -0'-3/4"
/1 6"
SLOPES
SLOPES
SLOPES
SLOPES
T/SLAB EL. = -0'-1 3/4"
T/SLAB
FLOOR
DRAIN, SEE
ARCH. DWGS.
FLOOR DRAIN,
SEE ARCH. DWGS.
S1. 18
S1. 19SLOPES
FLOOR DRAIN, SEE
ARCH. DWGS.
T/SLAB AT DRAIN
EL. = -0'-1 1/2"
FLOOR
DRAIN,
SEE
ARCH.
DWGS.
T/SLAB
AT DRAIN
EL. = -0'-1
1/2"
SLOPES
SLOPES
SLOPES
S1. 19
T/SLAB AT EDGES
EL. = -0'-1"
SLOPES
S1. 17
S1. 17
SIM
S1. 17
S1. 17
T/SLAB EL.
S1. 18
S1. 18
'-6
'-2
/8
'-8
/4
8' -3
3'
-8
/8
9' -2
/8
4'
-1
1/ 2"
4' -0
/2
S1. 19
S1. 18
BEAM
T/SLAB EL. = -0'-1/2"
S1. 18
12" x 20" CONC.
BEAM. SEE NOTE 9 EL. = -0'-1"
AT EDGE = -0'-1/2"
S1. 18
SIM.
S1. 18
S1. 18
3'-0 3/16"
PIER & GIRDER
7 13/16"
T/DECK EL. AT
WALL = -0'-1/2"
T/DECK EL. AT
EDGE = -0'-2"
2"
T/DECK EL. AT
EDGE = -0'-1 1/4"
6' -1
/8
'-1
/8
/1 6"
9' -5
3/
2"
PIER & GIRDER
EQ EQ
2- 3x
2- 3x
2- 3x
2- 3x
16 x 16 CMU
PIER, SEE
NOTE 12.
8 x 16 CMU
PIER, SEE
NOTE 12
3x
2'
-0
3x
2'
-0
3x
2' -0
3x
2'
-0 "2 x 6 DECKING
SEE NOTE 13 BELOW
SL
O
PE
S
SL
O
PE
S
S1. 17
S1. 17
S1. 17
S1. 17
CONC. COLUMN
C3, SEE NOTE 14
S1. 19SIM.
S1. 16
S1. 16
/1 6"
ADMINISTRATIVE
BUILDING
CONF &
ARCHAEOLOGY
BUILDING
STORAGE BUILDING
KEY PLAN
AREA
VIRGIN ISLANDS NATIONAL PARK
LIND POINT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
DATE
TECH. REVIEW:
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
CADD:
251144B
160151S1.
RMS (ARCHAEOLOGY) -
MAIN LEVEL SLAB PLAN
11/04/2020
LGC & TGM
DWU
190 345
DWU
1/4" = 1'-0" Main Level Slab Plan - Archaeology
NOTES:
1. 12" CMU WALLS EXTEND FROM FOUNDATION TO TOP OF PARAPET. REINFORCE W/ #6 VERTICAL @ 16"O.C. (FOUNDATION TO FIRST FLOOR) &
#6 VERTICAL @ 24"O.C. (FIRST FLOOR TO ROOF).
2. 8" CONCRETE SLAB TO BE REINFORCED W/ #5 @ 8" O.C. EA. WAY, TOP & BOTTOM.
3. 24" x 24" CONCRETE BEAM (16" BELOW BOTTOM OF SLAB) TO BE REINFORCED W/ 5-# 7 TOP & BOTTOM & #3 STIRRUPS @ 8" O.C.
4. 12" x 18" CONCRETE COLUMNS TYPE C1 TO BE REINFORCED W/ 6-#7 VERTICAL & #3 TIES @ 6" O.C.
5. COORD. SLAB ELEVATIONS & SLOPE FOR EXTERIOR SLABS W/ ARCH. DWGS.
6. CONCRETE SLAB AT EXTERIOR PORCHES TO BE REINFORCED W/ #5 @ 12" O.C. EA. WAY TOP, & #5 @ 8"O.C. EA. WAY BOTTOM. SET BOTTOM
OF SLAB EL. = -0'-10 1/2" T/SLAB SURFACE SLOPES, SEE PLAN.
7. 12" CMU RETAINING WALLS TO BE REINFORCED W/ #6 @ 16"O.C. EA. FACE VERTICAL. FILL ALL CORES SOLID W/ 3000psi GROUT. SEE SHEET S1.04.
8. 12" x 20" CONCRETE BEAMS AT EXTERIOR PORCHES TO BE REINFORCED W/ 4-#6 TOP & BOTTOM & #3 STIRRUPS @ 8" O.C.
9. 12" x 12" CONCRETE COLUMNS TYPE C2 TO BE REINFORCED W/ 4-#6 VERTICAL & #3 TIES @ 6" O.C.
10. 24" x 24" CONCRETE BEAMS TO EXTEND 16" BELOW BOTTOM OF SLAB & BE REINFORCED W/ 4-#7 TOP & BOTTOM & #3 STIRRUPS @ 8" O.C.
11. GATE SUPPORTS ARE REQUIRED FOR THIS PROJECT. THEY WILL REQUIRE PLATES BOLTED TO THE FACE OF CMU WALLS AT SELECTED
LOCATIONS. SEE ARCH. DWGS. FOR LOCATIONS & EXTENT. SEE STRUCTURAL DETAIL SHEET S1.21 FOR REQ'S.
12. 16 x 16 CMU PIERS TYP. AT EXTERIOR EDGE OF DECK. REINFORCE W/ 1-#5 IN EA. OF 4 CORES. 8 x 16 CMU PIERS TYP. AT BUILDING ADJACENT
EDGE OF DECK. REINFORCE W/ 1#5 IN EA. OF 2-CORES.
13. ALL WOOD FRAMING MEMBERS AT DECK TO BE PRESSURE TREATED.
14. CONCRETE COLUMN C3 TO BE 11 5/8" x 17 5/8" AND BE REINFORCED W/ 4-#6, VERTICAL & #3 TIES @ 6"O.C. EXTEND FROM FOUNDATION TO PATIO ROOF.
A A
12" CMU WALL
(BELOW)
SEE NOTE 2
12" CMU WALLS, TYP. AT
EXTERIOR. SEE NOTE 2
CC
EE
GG
1 3/4" EXP. JOINT
S1. 30
'-1
/8
'-0
/2
1'-1 9/16" 11'-9 15/16" 1'-7 11/16"
S1. 31
SL
O
PE
S
S1. 29
S1. 29
'-1
7/
8"
'-8
/8
4' -6
SEE SHEET S1.07 FOR
STORAGE BUILDING ROOF
FRAMING PLAN
S1. 291
S1. 31
S1. 31
S1. 30
SEE SHEET
S1.11 FOR
ADMIN.
BUILDING
ROOF
FRAMING
PLAN
12"
CMU
WALL
M
AT
C H
L
IN
E
SE
E S1
. 1
M
AT
C H
L
IN
E
SE
E S1
. 1
MATCH LINE SEE S1. 07
MATCH LINE SEE S1. 07
M
AT
C H
L
IN
E
SE
E S1
. 0
M
AT
C H
L
IN
E
SE
E S1
. 0
14'-7 3/16" 10'-0 3/4" 23'-8 3/8" 16'-3 5/8" 18'-4 3/8"
MATCH LINE SEE ---
MATCH LINE SEE ---
1' -3
/8
S1. 29 2
S1. 29
S1. 29
S1. 31
S1. 30
S1. 29
S1. 30
1'-10 3/16"
5 SP. @ 4'-0" = 20'-0"
1'-10 3/16" 2'-1 13/16"
3 SP. @ 4'-0" =12'-0"
2'-1 13/16" 1'-2 3/16"
4 SP. @ 4'-0" =16'-0"
1'-2 3/16"
W 8X
W 8X
W 8X
W 8X
W 8X
W 8X
W 8X
W 8X
W 8X
W 8X
W 8X
W 8X
W 8X
W 8X
W 8X
12" CMU
WALLS, TYP.
AT EXTERIOR.
SEE NOTE 2.
1 1/2" x 18 GA. TYPE B
GALV. METAL ROOF DECK,
TYP. THROUGHOUT
1/
2" 8'
-4
/2
C
LR
3' -4
/4
1/
4"5
/1 6"
'-7
3/
3x14
3x14
3x14
3x14
3x14
3x14
3x14
4' -0
4'
-0
4' -0
4'
-0
4' -0
3x14
3x14
3x14
4' -0
/4
4'
-0
/4
4' -0
1' -1
1/
4" 2'
-0
/4
1/
3' -4
5/
3x14
3' -8
/8
8'
-3
2-3x14
2-3x14
3x
3x14
3x14
2- 3x
EQ
EQ
EQ
3x14
1'-4 5/16"
8'-2"(±) CLR.
2'-3 5/8"
7' -1
0"
) C
LR
2- 3x
12" x 22" CONC.
BEAM W/ 4-#6,
TOP & BOTTOM
& #3 STIRRUPS
@ 12"O.C.
12" x 24" CONC.
BEAM W/ 4-#6,
TOP & BOTTOM
& #3 STIRRUPS
@ 12"O.C.
CONC. COLUMN
C2 BELOW, TYP.
6-LOCATIONS
S1. 30 4
S1. 30
CONNECT 3 x 14 JOISTS TO OTHER 3 x 14
MEMBERS W/ STAINLESS STEEL JOIST HANGERS
TYP. AT ENTIRE PATIO ROOF
S1. 31
'-8
/8
'-1
7/ 8"
'-1
/8
EXTEND 11 5/8" x 20" CONC. BEAM FROM BUILDING WALL. SEE
SECTION 4, SHEET S1.30. BEAR ON STORAGE BUILDING WALL
EXTEND 11 5/8" x 20" CONC. BEAM FROM
BUILDING WALL. SEE SECTION 4, SHEET S1.30
S1. 35
S1. 30SIM.
CONCRETE COLUMN C3, SEE NOTE 8.
SL
O
PE
S
SL
O
PE
S
T/PLYWOOD
EL. = 14'-4"
(AT RIDGE)
3x14
3x14
3x14
T/PLYWOOD
EL. = 14'-0"
(AT EDGE)
T/PLYWOOD
EL. = 14'-0"
(AT EDGE)
T/PLYWOOD
EL. = 14'-1 13/16"(±)
(AT EDGE)
ADMINISTRATIVE
BUILDING
CONF &
ARCHAEOLOGY
BUILDING
STORAGE BUILDING
KEY PLAN
AREA
VIRGIN ISLANDS NATIONAL PARK
LIND POINT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
DATE
TECH. REVIEW:
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
CADD:
251144B
160151S1.
RMS (ARCHAEOLOGY) -
ROOF FRAMING PLAN
11/04/2020
LGC & TGM
DWU
191 345
DWU
1/4" = 1'-0" Roof Framing Plan - Archaeology
NOTES:
1. COORDINATE ROOF SLOPE ELEVATIONS W/ ARCH. DWGS.
2. 12" CMU WALLS EXTEND FROM FOUNDATION TO TOP OF PARAPET. REINFORCE W/ #6 VERT. @ 16" O.C. (FOUNDATION TO FIRST FLOOR) & #6 VERT. @ 24"O.C. (FIRST FLOOR TO ROOF).
FOR TYPICAL WALL REINFORCING.
3. SEE ARCHITECTURAL DRAWINGS FOR TOP OF DECK ELEVATION AT CANOPY.
4. FALL PROTECTION STANCHIONS ARE REQUIRED FOR THIS PROJECT. THEY WILL REQUIRE TO ROOF FRAMING. SEE ARCH. DWGS. FOR NUMBER & LOCATIONS. SEE DETAIL, SHEET S1.37
FOR STRUCTURAL REQUIREMENTS.
5. ALL WOOD FRAMING AND DECKING TO BE PRESSURE TREATED.
6. ALL STEEL FRAMING, BOLTS, & METAL DECKING TO BE GALVANIZED.
7. CONCRETE COLUMN C2 TO BE 12" x 12" AND BE REINFORCED W/ 4-#6 VERTICAL & #3 TIES @ 6"O.C.
8. CONCRETE COLUMN C3 TO BE 11 5/8" x 17 5/8" AND BE REINFORCED W/ 4-#6, VERTICAL & #3 TIES @ 6"O.C. EXTEND FROM FOUNDATION TO PATIO ROOF. 0 2 4 8
W1 W2
3" CLR.3"
C
LR
2"
C
LR
1' -4
2'
-0
LOW SIDE FINISHED GRADE
GRADE AT HIGH SIDE
G R
AD
E
D
IF
FE
R
EN
C
E
BOTTOM TRANSVERSE
REINFORCING
TOP TRANSVERSE REINFORCING
W/ STD. 90° HOOKS AT ENDS
TOP LONGITUDINAL
REINFORCING (W/ 90°
HOOKS AT ENDS)
BOTTOM
LONGITUDINAL
REINFORCING
WALL
W (TOTAL)
12" CMU WALL. REINFORCE W/
2-#6 VERTICAL @ 8"O.C. OR 16"O.C.
SEE SCHEDULE. FILL ALL CORES
SOLID W/ 3000psi GROUT.
EQ. 5 1/2" EQ.
X
12" BOND BEAM W/ 2-#6 (CONT.)
GRADE
DIFFERENCE
UP TO 4 FT.
WALL
THICKNESS
(X)
12" CMU
FOOTING
WIDTH
W (TOTAL)
3'-0"
TOP
4-#5
BOTTOM
#4 @ 12" O.C.
4 FT TO 6.5 FT 12" CMU 4'-6"
SITE RETAINING WALL & FOOTING SCHEDULE
LONGITUDINAL TRANSVERSE LONGITUDINAL TRANSVERSE
W1
1'-6"
1'-6" 5-#5 #5 @ 12" O.C.
4-#5
5-#5
6.5 FT TO 8 FT 12" CMU 6'-6" 2'-3" 6-#6 #5 @ 12" O.C. 6-#6
#4 @ 12" O.C.
#5 @ 12" O.C.
#5 @ 12" O.C.
W2
1'-6"
3'-0" 4'-3"
VERTICAL WALL
REINFORCING
2-#6 @ 16"O.C.
2-#6 @ 16"O.C.
2-#6 @ 8"O.C.
FOOTING REINFORCING
1' -4
H
EI
G H
T O
F F O
O
TI
N G
S T E
PS
8" to
'-0
" C O
O R
D . W
/ F
IE
LD
C
O N
D
IT
IO
N
S
FO
R L
O C
AT
IO
N S
2'-0"
3" C
LR
3" C
LR
2" C
LR
2" C
LR
1' -4
MATCH SIZE & NUMBER OF
FOUNDATION LONGITUDINAL
BARS. PROVIDE 3'-0" SPLICE
LENGTH AT EA. FTG.
RETAINING WALL
FOUNDATION. SEE
SCHEDULE, THIS SHEET
VIRGIN ISLANDS NATIONAL PARK
LIND POINT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
DATE
TECH. REVIEW:
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
CADD:
251144B
160151S1.
SITE RETAINING WALL
DETAIL
11/04/2020
LGC & TGM
DWU
192 345
DWU
NOTES:
1. SEE CIVIL DRAWINGS FOR LOCATIONS OF SITE WALLS & FOR GRADE DIFFERENCE ON EACH SIDE OF WALL.
2. PROVIDE STEPPED FOOTINGS WHERE GRADE TRANSITIONS.
3. ALIGN EXTERIOR FACES OF CONCRETE RETAINING WALLS WHERE WALL THICKNESS CHANGES ALONG LENGTH OF RETAINING WALL.
4. SEE ARCHITECTURAL DRAWINGS FOR DRAINAGE DETAILS & REQUIREMENTS WHERE REQUIRED ADJACENT TO RETAINING WALLS.
5. PROVIDE CONTROL JOINTS IN WALLS AT A SPACING NOT TO EXCEED 30'-0".
1" = 1'-0"
FOOTING STEP DETAIL
0 0.5 1 2
SCALE: 1" = 1'-0"
FTG. 5
FTG. 4
FTG. 4
FT
G
. 4
FT
G
. 4
T/FTG EL. = -6'-0"
T/FTG EL. = -4'-8"
2' -9
1'
-9
1'-9" 2'-9"
1' -9
2'
-9
18" x 18" CONCRETE
PEDESTAL (P1). SEE
NOTE 4
GG
J
LL
9 11 12 15 16 18
INSIDE
FACE OF
CMU WALL
T/FTG EL. = -6'-0"
12" CMU RETAINING
WALL. SEE NOTE 3
4' -0
WIDEN FTG. 4
BY 3'-6". SEE
NOTE 6
12" CMU WALLS
SEE NOTE 2
4'-0" TALL OPENING IN WALL FOR
DUCTWORK. COORD. EXACT
REQUIREMENTS W/ ARCH. DWGS.
CONC. COLUMN
C2. SEE NOTE 6
INSIDE FACE OF
CMU WALL
M
AT
C H
L
IN
E
SE
E S1
. 0
M
AT
C H
L
IN
E
SE
E S1
. 0
FTG. 4
MATCH LINE SEE S1. 01
MATCH LINE SEE S1. 01
2' -9
1'
-9
3' -6
3' -6
T/FTG EL. = -6'-0"
T/FTG EL. = -6'-0"
T/FTG EL. = -8'-4"
1' -2
/2
1' -2
/2
T/FTG EL. = -8'-4"
12" CMU WALL
12" CMU
RETAINING
WALL, SEE
NOTE 4FT
G . 2
5'-1 3/8" 10'-2 13/16"
21'-7" 8'-10"15'-7 3/4" 17'-3"
T/FTG.
15'-4 3/16"
S1. 16
S1. 20
8'-9 13/16"(±)
2' -6
/1
6"
3' -6
'-4
'-4
3'
-6
2'-9" 1'-9"
3' -0
1'-10 3/16" 10 1/16"
P1 P1 P1 P1
PEDESTAL P1, TYP 4-LOCATIONS.
SEE NOTE 4 BELOW.
12" CMU WALLS,
SEE NOTE 2
12" CMUEL. = 11'-0"
S1. 20
INSIDE FACE OF
CMU WALL
CONC. COLUMN
C3. SEE NOTE 8
12" CMU WALLS
SEE NOTE 2
8" CMU FOR
SUPPORT OF
STONE VENEER.
SEE NOTE 7.
ADMINISTRATIVE
BUILDING
CONF &
ARCHAEOLOGY
BUILDING
STORAGE BUILDING
KEY PLAN
AREA
VIRGIN ISLANDS NATIONAL PARK
LIND POINT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
DATE
TECH. REVIEW:
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
CADD:
251144B
160151S1.
RMS (STORAGE) -
FOUNDATION PLAN
11/04/2020
LGC & TGM
DWU
193 345
DWU
1/4" = 1'-0" Foundation Plan - Storage Building
0 2 4 8
SCALE: 1/4" = 1'-0"
NOTES:
1. SEE SHEET S1.15 FOR TYPICAL SECTION THROUGH FOOTING & FOOTING SCHEDULE.
2. 12" CMU BUILDING WALLS TO BE REINFORCED W/ #6 VERT. @ 24"O.C.
3. 12" CMU RETAINING WALLS TO EXTEND FROM FOUNDATION TO FIRST FLOOR SLAB LEVEL. REINFORCE W/ #6 VERT. @ 16" O.C. FILL ALL CORES SOLID W/ GROUT.
4. CONCRETE PEDESTALS P1 ARE 18" SQUARE. REINFORCE W/ 4-#7 VERTICAL & #3 TIES @ 6" O.C. SEE DETAIL, SHEET S1.22.
5. CONCRETE COLUMNS C2 ARE 12" x 12" & EXTEND TO EXTERIOR PATIO ROOF LEVEL. REINFORCE W/ 4-#6 VERT. & #3 TIES @ 6" O.C.
6. AT WIDENED FTG. 4, PROVIDE ADDITIONAL 3-#6 TOP & BOTTOM LONGITUDINAL. EXTEND #5 TRANSVERSE TOP & BOTTOM TO FILL WIDTH OF WIDENED FTG.
7. STONE VENEER SHOWN. STONE TO BE SUPPORTED ON 8" CMU AT LOCATIONS WITHOUT SLAB. PROVIDE 8 INCH CMU UP TO 12 INCHES BELOW GRADE
SUPPORT OF STONE VENEER. REINFORCE 8 INCH CMU WITH #5 VERT. @ 24"O.C. GROUT ALL CELLS SOLID. COORDINATE EXTENTS OF STONE VENEER UNDER
BASE BID W/ ARCHITECTURAL DRAWINGS.
8. CONCRETE COLUMN C3 TO BE 11 5/8" x 17 5/8" AND TO BE REINFORCED W/ 4-#6 VERT. & #3 TIES @ 6"O.C.
C.J. C.J. C.J. C.J. C.J.
C .J
C
.J
C .J
C .J
C .J
C .J
C .J
15'-7 3/4" 17'-3" 21'-7" 8'-10" 15'-4 3/16"
INSIDE FACE
OF CMU WALL
COLUMNS
INSIDE FACE
OF CMU WALL
INSIDE FACE
OF CONCRETE
WALL
8 1/2" CONCRETE
SLAB ON GRADE.
SEE NOTE 2
CONCRETE PEDESTAL
P1, TYP. WHERE
SHOWN. SEE NOTE 3.
GG
JJ
LL
9 11 12 15 16 18
C .J
C
.J
2-#4 x 2'-0" AT RE-
ENTRANT CORNERS
THICKENED SLAB
TS1, SEE
SECTION 1, S1.21
SEE SHEET
S1.02 FOR
FLOOR
FRAMING
PLAN, THIS
AREA
12" CMU WALLS
BELOW. SEE NOTE 1
4'-0" TALL OPENING IN WALL
FOR DUCTWORK. COORD. W/
ARCH. DWGS.
M
AT
C H
L
IN
E
SE
E S1
. 0
MATCH LINE SEE S1. 02
'-4
'-4
ISOLATION JOINT AT 4
SIDES OF PEDESTAL
(TYP.)
4 1/4" (±)
12'-7 5/8"
ISOLATION JOINT ISOLATION JOINT
ISOLATION JOINT ISOLATION JOINT
9'-5 3/16" 12'-1 13/16" 5'-1 3/8" 10'-2 13/16"
12" CMU
RETAINING
WALL, SEE
SHEET S1.02
FOR REQ'S
S1. 20
S1. 20
S1. 20
S1. 21
S1. 21
S1. 21
S1. 21
3' -0
1' -8
/1
6"
S1. 19
SLOPES
2" DEPRESSED
SLAB 2" DEPRESSED
SLAB
SIM
SIM
S1. 20
C .J
S1. 20
SIM
8" CMU WALL, SEE
SECTION 3/S1.20
THICKENED SLAB. SEE
SECTION 3/S1.20
THICKENED SLAB. SEE
SECTION 3/S1.20
8" CMU WALL,
SEE SECTION
3/S1.20
S1. 20
MATCH LINE SEE S1. 02
M
AT
C H
L
IN
E
SE
E S1
. 0
S1. 20
12" CMU WALL
BELOW. SEE
NOTE 1
P1 P1 P1 P1
12" CMU WALL, REINFORCE
W/ #6 VERT. @ 24"O.C.
8" CMU WALL, SEE
SECTION 3/S1.20
COORD. W/ ARCH. DWGS.
9'-4 11/16"(±)
C O
O R
D . W
/ A R
C H
. D W
G S.
9' -8
/2
ADMINISTRATIVE
BUILDING
CONF &
ARCHAEOLOGY
BUILDING
STORAGE BUILDING
KEY PLAN
AREA
VIRGIN ISLANDS NATIONAL PARK
LIND POINT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
DATE
TECH. REVIEW:
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
CADD:
251144B
160151S1.
RMS (STORAGE) - FIRST
FLOOR SLAB PLAN
11/04/2020
LGC & TGM
DWU
194 345
DWU
1/4" = 1'-0" First Floor Slab Plan - Storage Building
NOTES:
1. 12" CMU WALLS, TYPICALLY. REINFORCE W/ #6 VERTICAL @ 24" O.C. FILL ALL CORES BELOW FIRST FLOOR SOLID W/ GROUT.
2. 8 1/2" (OR 6 1/2" AT DEPRESSED SLAB) CONCRETE SLAB ON GRADE TO BE SUPPORTED ON COMPACTED FILL. REINFORCE W/
#5 @ 8" O.C. EA. WAY AT MID-DEPTH OF SLAB. PROVIDE 2" CONCRETE TOPPING AT DEPRESSED SLAB. TOPPING TO BE CAST W/ 4000 psi PEAGRAVEL
CONCRETE MIX. BOND TOPPING SLAB TO BASE SLAB W/ BONDING AGENT PRIOR TO POUR.
3. CONCRETE PEDESTAL (P1) TO BE REINFORCED W/ 4-#7 VERTICAL & #3 TIES @ 6" O.C.
15'-7 3/4" 17'-3" 21'-7" 8'-10"
INSIDE FACE OF CMU WALL
COLUMNS
INSIDE FACE
OF CMU WALL
INSIDE FACE
OF CMU WALL
4 1/2" CONCRETE SLAB ON 1 1/2" x 18 GA.
GALV. COMPOSITE METAL FLOOR DECK.
REINFORCE W/ 4 x 4 - W4.0 x W4.0 WWF
AT MID-DEPTH OF SLAB
(SEE NOTE 3)
SLOPES
G
J
L
9 11 12 15 16 18
SEE
SHEET
S1.03 FOR
CANOPY
FRAMING,
THIS AREA
S1. 32
S1. 32
S1. 33
S1. 33
S1. 33
M
AT
C H
L
IN
E
SE
E S1
. 0
M
AT
C H
L
IN
E
SE
E S1
. 0
S1. 32
S1. 32
12" CMU WALL BELOW
15'-4 3/16"
'-4
'-4
S1. 31
8" CMU WALL
BELOW
S1. 31
8" CMU
WALLS
BELOW
W12X30 (GALV.) W12X30 (GALV.) W14X43 (GALV.) W8X18 (GALV.) W12X30 (GALV.)
W 8X
(G
AL
V.
W
8X
(G
AL
V.
W 8X
(G
AL
V.
W
8X
(G
AL
V.
W 8X
(G
AL
V.
W
8X
(G
AL
V.
W 8X
(G
AL
V.
W
8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W
8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W
8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W
8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W
8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W
8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
HSS5X5X5/16
(GALV.)
HSS5X5X5/16
(GALV.) HSS5X5X5/16
(GALV.)
HSS5X5X5/16
(GALV.)
S1. 33
S1. 33
S1. 33
S1. 33
3 SP. @ 3'-9" = 11'-8" 3'-8 3/16"3 SP. @ 3'-1" = 8'-10"6 SPACES @ 3'-9" = 21'-7"4 SPACES @ 4'-1" = 17'-3"3'-7 3/4" 4 SPACES @ 4'-0" = 12'-0"
S1. 31
12" CMU WALL, REINFORCE
W/ #6 VERT. @ 24"O.C.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
W 8X
(G
AL
V.
(SEE NOTE 2) (SEE NOTE 2) (SEE NOTE 2) (SEE NOTE 2) (SEE NOTE 2)
12" CMU WALLS,
TYP 4-SIDES.
REINFORCE W/
#6 VERT. @ 24"O.C.
STONE VENEER,
SEE ARCH. DWGS.
ADMINISTRATIVE
BUILDING
CONF &
ARCHAEOLOGY
BUILDING
STORAGE BUILDING
KEY PLAN
AREA
VIRGIN ISLANDS NATIONAL PARK
LIND POINT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
DATE
TECH. REVIEW:
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
CADD:
251144B
160151S1.
RMS (STORAGE) - ROOF
FRAMING PLAN
11/04/2020
LGC & TGM
DWU
195 345
DWU
1/4" = 1'-0" Roof Framing Plan - Storage Building
NOTES:
1. W8 x 13 & W8 x 18 ROOF BEAMS TO HAVE 3/4"ø x 3 1/2" LG. WELDED HEADED STUDS WELDED THROUGH DECK TO BEAM TOP
FLANGE AT ALTERNATE FLUTES.
2. W8 x 18, W12 x 30 & W14 x 43 ROOF GIRDERS TO HAVE 3/4"ø x 3 1/2" LG. WELDED HEADED STUDS WELDED THROUGH DECK
TO BEAM TOP FLANGE AT EVERY FLUTE.
3. TOP SURFACE OF SLAB SLOPES TO ROOF DRAINS. BOTTOM SURFACE SLOPES FROM LINE 'L' TO LINE 'G'. MINIMUM SLAB
THICKNESS = 4 1/2", SEE DETAILS. REINFORCE W/ 4 x 4 - W4.0 x 4.0 WWF AT MID-DEPTH OF SLAB. COORDINATE TOP
SURFACE SLOPES WITH ARCHITECTURAL ROOF PLAN SLOPES.
4. FALL PROTECTION STANCHIONS ARE REQUIRED FOR THIS PROJECT. THEY WILL REQUIRE ANCHORAGE TO STEEL FRAMING.
SEE DETAIL, SHEET S1.37 FOR STRUCTURAL REQUIREMENTS.
5. ALL STEEL FRAMING, BOLTS, COLUMNS, & CONNECTIONS AND ALL METAL DECKING TO BE GALVANIZED.
5 6
7 8
A A
B B
D D
F F
H H
K K
FTG. 8FTG. 8FTG. 8
FT
G
. 3
FTG. 3
FTG. 10
FT
G
. 7
FT
G
. 7
FTG. 8
FT
G
. 6
FT
G
. 6
FTG. 8
FTG. 8
FTG. 9
FTG. 9 FTG. 9
FTG. 9
FT
G
. 6
FT
G . 6
FTG. 10
FTG. 3
FT
G
. 3
FT
G
. 6
FT
G . 6
FT
G
. 6
12" CMU
WALL. SEE
NOTE 7
9' -0
'-1 1"
9' -3
'-8
/8
12" x 18" CONC.
COL. (C1) SEE
NOTE 4
T/FTG. EL. = -11'-0" T/FTG. EL. = -11'-0"
12" x 12"
CONC.
COLUMN C2,
SEE NOTE 6
12" CMU OR
11 5/8" CONC.
WALL
FTG. 9
S1. 22
S1. 22
S1. 22
S1. 22
S1. 22
S1. 22
FT
G
. 7
FT
G
. 6
FT
G
. 7
CONC. COLUMN
C1, TYP. THIS LINE
CONCRETE
COLUMNS C1
FT
G
. 6
FT
G
. 6
2' -0
SEE SHEET
S1.13 FOR
FOUNDATIONS &
WALLS IN THE
MECHANICAL
YARD
M
AT
C H
L
IN
E
SE
E S1
. 1
SEE SHEET S1.13 FOR
FOUNDATIONS & WALLS
AT EXTERIOR STEPS
8" CONCRETE WALLS
AT CATCH BASIN
T/FTG.
EL. = -11'-0"
TYP. U.N.O.
S1. 22
S1. 22
S1. 22
S1. 23
S1. 22
S1. 25
S1. 16
4' -8
/1
6"
'-8
/8
9' -3
'-1 1"
9' -0
'-6
17'-5 3/8" 15'-11" 20'-8" 21'-11" 11'-1"
17'-5 3/8"
12" CMU
OR 11 5/8"
CONC. WALL
12" CMU WALL &
CONC. COLUMNS
12" CMU WALL
& CONC. COLUMNS
CONC.
COLUMNS
CONC.
COLUMN
CONC.
COLUMNS
12" CMU WALL
15'-11" 20'-8" 18'-10" 14'-2"
2" C
M U
W
AL
L
12" x 18" CONCRETE
COLUMN C1, SEE NOTE 4
" C O
N
F O
U N
D
AT
IO
N
W
AL
L
C
O N
LU
M N
(B
EY
O
N D
C
M U
LS
N
LU
M
S
5/
8"
N
L
FTG. 8 FTG. 8
S1. 22
S1. 23
12" CMU WALLS &
CONCRETE COLUMNS
S1. 23
S1. 23
0"
FTG. 8
2'-0"
12" CMU WALL 12" CMU WALL
-11'-0" -13'-0"
-11'-0" -13'-0"
-11'-0" -13'-0"
-1 3'
-0 " -1
5' -0
CONC.
COLUMNS
S1. 23
S1. 22
S1. 23
S1. 22
S1. 23 3
S1. 23
FT
G
. 6
12" CMU
WALL &
COLUMN
CONCRETE
COLUMN C1
12" CMU
WALL &
COLUMN
COLUMN
12"
CMU
WALL
8" CONC.
WALL
12" x 18" CONCRETE COLUMN
C1, SEE NOTE 4
12" x 18" CONCRETE
COLUMN C1, SEE
NOTE 4
S1. 22
FT
G
. 6
FT
G . 6
3'-2"
8"
3'-0"
S1. 22
M
AT
C H
L
IN
E
SE
E S1
. 1
1'-1 9/16"
'-6
'-1
1" 4'
-5
1/
4'
-6
/1 6"
2' -4
'-7
5'-5 3/8" 3'-6"
8" CONCRETE
FOUNDATION
WALL
11 5/8" CONC.
WALLS, TYP.
4-SIDES AT
CISTERN
-13'-0" -15'-0" -11'-0"
-13'-0"
S1. 22
S1. 22
S1. 22
FOOTING
STEP
5' -0
S1. 23
S1. 22
S1. 22
12" CMU WALLS,
TYP. WHERE
SHOWN, U.N.O.
SEE NOTE 7
S1. 22
S1. 23
12" CMU WALLS,
TYP. WHERE
SHOWN, U.N.O.
COLUMN
FTG. 8
12" CMU WALLS,
TYP. WHERE
SHOWN, U.N.O.
SEE NOTE 7
ADMINISTRATIVE
BUILDING
CONF &
ARCHAEOLOGY
BUILDING
STORAGE BUILDING
KEY PLAN
AREA
VIRGIN ISLANDS NATIONAL PARK
LIND POINT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
DATE
TECH. REVIEW:
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
CADD:
251144B
160151S1.
RMS (ADMIN) -
FOUNDATION PLAN
11/04/2020
LGC & TGM
DWU
196 345
DWU
1/4" = 1'-0" Foundation - Admin
NOTES:
1. T/FTG. EL. = -11'-0", TYP. U.N.O.
2. SEE SHEET S1.15 FOR TYPICAL SECTION THOUGH FOOTING & FOOTING SCHEDULE.
3. ALL FOOTINGS TO BE CENTERED ON 12" CMU WALLS, 11 5/8" CONCRETE WALLS, OR 12" x 18" CONCRETE COLUMNS, U.N.O.
4. CONCRETE COLUMNS C1 ARE 12" WIDE x 18" LG & EXTEND FROM FOUNDATION TO FIRST FLOOR LEVEL. REINFORCE W/ 6-#7 VERT. & #3 TIES @ 6" O.C.
5. 11 5/8" CONCRETE WALLS TO BE REINFORCED W/ #5 @ 6" O.C. EA. FACE, VERT. & #4 @ 12" O.C. EA. FACE, HORIZ. SEE SHEET S1.15 FOR TYPICAL WALL
REINFORCING DETAIL.
6. CONCRETE COLUMNS C2 ARE 12" x 12" & EXTEND TO EXTERIOR PLAZA ROOF LEVEL. REINFORCE W/ 4-#6 VERT. & #3 TIES @ 6" O.C.
7. 12" CMU WALLS ARE TO BE REINFORCED W/ #6 VERT. @ 16"O.C. (FOUNDATION TO FIRST FLOOR) & #6 VERT. @ 24"O.C. (FIRST FLOOR TO ROOF)
5 6
7 8
A A
B B
D D
F F
H H
K K
C .J
S1. 22
S1. 22
S1. 22
S1. 22
S1. 22
S1. 22
S1. 22
M
AT
C H
L
IN
E
SE
E S1
. 1
S1. 22
S1. 22
S1. 23
S1. 22
S1. 25
S1. 16
S1. 22
S1. 23
S1. 22
S1. 23
SL
O
PE
S
SLOPES
8" CONCRETE
SLAB FOR
CISTERN, SEE
NOTE 2
8" CONCRETE
WALL BELOW
11 5/8"
CONCRETE
WALLS, TYP.
4-SIDES OF
CISTERN
C.J.
C .J
C
.J
C.J.
C.J. C.J.
12" x 18" COLUMNS
TYPE C1 (TYP.) SEE
NOTE 5
C .J
C .J
C.J. C.J.
C .J
C
.J
C .J
C .J
C .J
S1. 22
C.J. C.J.
C .J
5" CONCRETE SLAB ON GRADE,
TYP. THROUGHOUT, U.N.O.
SEE NOTE 3
12" x 18" CONCRETE
COLUMN TYPE C1.
SEE NOTE 5
5" CONCRETE
SLAB ON
GRADE, SEE
NOTE 3
C.J. C.J.
C .J
. C .J
C .J
S1. 22
S1. 23
S1. 22
S1. 23
S1. 22
S1. 23
C.J.
C .J
C.J.
12" x 12"
CONCRETE
COLUMN
C2, TYP.
SEE NOTE 6
2-#4 x 2'-0" LG. AT
RE-ENTRANT CORNERS
12" x 18" COLUMNS
TYPE C1 (TYP.)
SEE NOTE 5
SEE SHEET
S1.14 FOR
MECH. YARD
SLABS,
WALLS &
STEPS, THIS
AREA
C .J
17'-5 3/8" 15'-11" 20'-8" 21'-11" 11'-1" 1'-1 9/16"
15'-11" 20'-8" 18'-10" 14'-2" 1'-1 9/16"
'-8
/8
9'
-3
'-1
1" 9'
-0
'-6
9' -0
'-1 1"
9' -3
'-8
/8
17'-5 3/8"
4' -5
1/
4' -6
/1
6"
CONCRETE COLUMN
C1, TYP. THIS LINE
CONCRETE
COLUMN C1
11 5/8" CONC. WALL,
12" CMU WALLS, &
CONC. COLUMNS
CONC. COLUMNS CONC. COLUMN C1
CONC. COLUMN C1
C
M U
W
L
O
LU
M
N
O
N C
. W
B
EL
O W
C
O N
LU
M
S
(B
EY
O N
D
12" CMU
WALLS &
CONCRETE
COLUMNS
C
C
M U
W
O
N
LU
M
N S
12" CMU WALLS &
CONCRETE COLUMNS 12" CMU WALL
C
N
LU
N
LU
M
N
N
LU
C
M U
W
O N
C R
ET
E
LU
M
N
C
N
LU
S1. 23
S1. 23
2'-0" x 2'-0"
CATCH
BASIN
T/SLAB EDGE AT
CATCH BASIN
EL. = -9'-1 1/2"
C .J
C.J.
C .J
C
.J
C .J
C.J. C.J.
C.J.
C.J.
S1. 22
C .J
C
.J
C .J
C
.J
C .J
C
.J
S1. 22
C.J.
SEE SHEET S1.14 FOR
FOUNDATIONS &
WALLS AT EXTERIOR
STEPS
M
AT
C H
L
IN
E
SE
E S1
. 1
'-6
12" CMU WALLS,
TYP. WHERE
SHOWN, U.N.O.
SEE NOTE 8
S1. 23
5" CONCRETE SLAB
ON GRADE, TYP.
THROUGHOUT,
U.N.O. SEE NOTE 3
5" CONCRETE SLAB ON GRADE,
TYP. THROUGHOUT, U.N.O.
SEE NOTE 3
S1. 22
12" CMU WALLS,
TYP. WHERE
SHOWN, U.N.O.
SEE NOTE 8
S1. 22
12" x 18" CONCRETE COLUMN
TYPE C1. SEE NOTE 5
C
M U
W
O N
C R
ET
LU
M N
S C
S1. 22
11 5/8" CONC. WALL,
& 12" CMU WALL
C .J
C .J
C
.J
C .J
C.J.
C.J.
12" CMU WALLS,
SEE NOTE 8
ADMINISTRATIVE
BUILDING
CONF &
ARCHAEOLOGY
BUILDING
STORAGE BUILDING
KEY PLAN
AREA
VIRGIN ISLANDS NATIONAL PARK
LIND POINT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
DATE
TECH. REVIEW:
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
CADD:
251144B
160151S1.
RMS (ADMIN) - LOWER
LEVEL SLAB PLAN
11/04/2020
LGC & TGM
DWU
197 345
DWU
1/4" = 1'-0" Lower Level Slab Plan - Admin
NOTES:
1. TOP OF GROUND FLOOR SLAB EL. = -9'-0", TYP. U.N.O.
2. 8" CONCRETE SLABS AT CISTERNS TO BE REINFORCED W. #5 @ 12"O.C., EA. WAY, TOP & #5 @ 12"O.C. ONE WAY, BOTTOM. SEE SECTION 4, SHEET S1.22.
3. 5" CONCRETE SLABS ON GRADE TO BE REINFORCED W/ 4 x 4 - W4.0 x W4.0 WWF AT MID-DEPTH OF SLAB.
4. 11 5/8" CONCRETE WALLS TO BE REINFORCED W/ #5 @ 6" O.C. VERTICAL EA. FACE & #4 @ 12" O.C. HORIZ. EA. FACE. SEE SHEET S1.15 FOR TYPICAL WALL
REINFORCING DETAILS.
5. 12" x 18" CONCRETE COLUMNS (C1) TO EXTEND FROM FOUNDATION TO FIRST FLOOR LEVEL. REINFORCE W/ 6-#7 VERTICAL & #3 TIES @ 6" O.C.
6. 12" x 12" CONCRETE COLUMNS (C2) TO EXTEND TO EXTERIOR PLAZA ROOF LEVEL. REINFORCE W/ 4-#6 VERT. & #3 TIES @ 6" O.C.
7. CONCRETE STEPS CAST ON GRADE SHALL HAVE A MINIMUM THICKNESS OF 6" & SHALL BE REINFORCED W/ #5 @ 8" O.C. EA. WAY & #4 @ EA. NOSING.
8. 12" CMU WALLS ARE TO BE REINFORCES W/ #6 VERT. @ 16"O.C. (FOUNDATION TO FIRST FLOOR) & #6 VERT. @ 24"O.C. (FIRST FLOOR TO ROOF). EXTEND
LOWER LEVEL VERTICAL BARS A MINIMUM OF 3'-0" ABOVE LEVEL 1 SLAB.
5 6
7 8
A A
B B
D D
F F
H H
K K
24" WIDE x 20" DEEP (12" BELOW
BOTTOM OF SLAB) CONCRETE
BEAM. SEE NOTE 6
24" WIDE x 24" DEEP
(16" BELOW BOTTOM
OF SLAB) CONCRETE
BEAM. SEE NOTE 5
24" WIDE x 24" DEEP (16" BELOW
BOTTOM OF SLAB) CONCRETE
BEAM. SEE NOTE 5
SEE ARCH. DWGS.
12" CMU WALLS, TYP.
THROUGHOUT U.N.O.,
SEE NOTE 8
12" CMU WALL, SEE NOTE 8
12" x 18" CONCRETE COLUMN TYPE
C1 BELOW, SEE NOTE 3
8" CONCRETE SLAB,
TYP. THROUGHOUT U.N.O.
SEE NOTE 4
12" CMU WALL,
TYP. WHERE
SHOWN, U.N.O.
SEE NOTE 8
12" CMU WALL, TYP.
WHERE SHOWN U.N.O.
SEE NOTE 8
11 5/8" CONCRETE WALL
BELOW, SEE NOTE 1
1 3/4" EXP.
JOINT
S1. 16
S1. 19
S1. 16
S1. 16
S1. 16
CONC.
COLUMNS
SEE SHEET S1.14
FOR EXTERIOR
STEPS & PLATFORM
FRAMING
S1. 17
S1. 17
S1. 17
S1. 16
S1. 17
S1. 25
S1. 25
S1. 16
S1. 25
M
AT
C H
L
IN
E
SE
E S1
. 0
SEE SHEET
S1.02 FOR
EXTERIOR DECK
FRAMING, THIS
AREA
S1. 19
'-8
/8
9'
-3
'-1
1" 9'
-0
'-6
15'-11" 20'-8"
4' -0
2' -0
3' -3
CONC.
BEAM &
11 5/8"
CONC.
WALL
(BELOW)
EDGE OF
SLAB
1'-9 3/8"(±)
2'-0"(±)
M
U W
AL
L
SEE SHEET S1.14
FOR SLABS &
STAIRS, THIS
AREA
SEE SHEET
S1.14 FOR
SLABS &
STAIRS,
THIS AREA
CONC.
COLUMNS
12" CMU WALLS,
CONCRETE BEAMS,
& CONCRETE
COLUMNS (BELOW)
CONC. COLUMNS &
BEAMS
17'-5 3/8" 15'-11" 20'-8" 21'-11" 11'-1" 1'-1 9/16"
'-8
/8
9'
-3
'-1
1" 9'
-0
S1. 19
S1. 19
S1. 25
11 5/8" CONCRETE
WALL (BELOW),
SEE NOTE 1
12" CMU
WALL
CONC.
COLUMNS
& BEAMS
CONC. BEAMS
& COLUMNS
(BELOW)
12" CMU WALL 12" CMU WALLS
& CONC. COLUMNS
(BELOW)
CONC.
COLUMN
S1. 19
S1. 25
S1. 17
S1. 25
S1. 25
S1. 25
17'-5 3/8"
SIM.
SIM.
18'-10" 14'-2" 1'-1 9/16"
M
AT
C H
L
IN
E
SE
E S1
. 1
M
AT
C H
L
IN
E
SE
E S1
. 1
M
AT
C H
L
IN
E
SE
E S1
. 0
'-6
12" CMU WALL,
TYP. THROUGHOUT
U.N.O., SEE NOTE 8
24" WIDE x 24" DEEP (16" BELOW BOTTOM
OF SLAB) CONCRETE BEAM. SEE NOTE 5
12" CMU WALL, TYP.
THROUGHOUT U.N.O.,
SEE NOTE 8
12" x 18" CONCRETE
COLUMN TYPE C1
BELOW, SEE NOTE 3
S1. 16
SEE ARCH. DWGS.
12" CMU WALL BELOW
12" CMU WALL BELOW
12" x 18" CONCRETE COLUMN TYPE
C1 BELOW, SEE NOTE 3
12" x 18"
CONCRETE
COLUMN TYPE
C1 BELOW, SEE
NOTE 3
12" CMU WALL, TYP. THROUGHOUT
U.N.O., SEE NOTE 8
24" WIDE x 24" DEEP (16" BELOW
BOTTOM OF SLAB) CONCRETE
BEAM. SEE NOTE 5
S1. 25
S1. 25
S1. 16
/1 6"
2' -4
/1
6"
HSS5x5x5/16
COLUMN UP TO
CLERESTORY
ROOF
S1. 23
S1. 24
S1. 24
S1. 24
S1. 24 5
S1. 24
S1. 24
S1. 24
S1. 25
#5 @ 8"O.C., TOP & BOTTOM
(OUTSIDE LAYER)
#5 @ 8"O.C., TOP & BOTTOM
(INSIDE LAYER)
ADMINISTRATIVE
BUILDING
CONF &
ARCHAEOLOGY
BUILDING
STORAGE BUILDING
KEY PLAN
AREA
VIRGIN ISLANDS NATIONAL PARK
LIND POINT
TITLE OF SHEETSUB SHEET NO.DESIGNED:
DATE
TECH. REVIEW:
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
CADD:
251144B
160151S1.
RMS (ADMIN) - MAIN
LEVEL SLAB PLAN
11/04/2020
LGC & TGM
DWU
198 345
DWU
1/4" = 1'-0" Main Level Slab Plan - Admin
NOTES:
1. 11 5/8" CONCRETE WALL. REINFORCE W/ #5 @ 6" O.C. VERT. EA. FACE & #4 @ 12" O.C. HORIZ. EA. FACE. SEE SHEET S1.15 FOR
TYPICAL WALL REINFORCING DETAILS.
2. T/SLAB EL. = 0'-0" TYP. U.N.O.
3. 12" x 18" CONCRETE COLUMNS C1 TO BE REINFORCED W/ 6-#7 VERTICAL & #3 TIES @ 6" O.C. TERMINATE VERTICAL BARS AT
BEAM TOP REINFORCING W/ STD. 90° HOOKS.
4. 8" CONCRETE SLAB AT FIRST…