This document is a Repair Qualification Requirements (RQR) for 124 National Stock Numbers (NSNs) grouped into 32 categories of electronic, mechanical, and electrical components. The document outlines the qualification process for potential repair sources, allowing offerors to apply for qualification for entire categories or individual NSNs across categories such as speed gear assemblies, radar sets, power supplies, motors, and electronic components.
Key requirements include submitting a Source Approval Request (SAR) package, demonstrating facilities and testing capabilities, verifying technical data packages, and developing qualification test plans. Offerors must repair items to conform to Government requirements, provide quality and performance data, and comply with unique identification standards. The qualification process costs approximately $10,000 per category, takes an estimated 60 days, and does not guarantee a contract award. Importantly, all qualification expenses are borne by the offeror, and the Government reserves the right to selectively qualify items within a category based on the offeror's demonstrated capabilities.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REPAIR QUALIFICATION REQUIREMENTS
NSN: [See Appendix A, Column B] P/N: [See Appendix A, Column C] Noun: [See Appendix A, Column D] Application: [See Appendix A, Column E]
20 Aug 2025 Section C 1/4
MAC IDIQ RQR QUALIFICATION INSTRUCTIONS:
This MAC IDIQ RQR contains 124 NSNs that have been grouped into numbered categories. Offerors wishing to apply for qualification for the NSNs listed in this RQR can decide from the following options:
1. Qualify for a category/categories of NSNs: For example, if an offeror believes they are qualified for all the NSNs in Category 30, they can state they wish to qualify for all of the NSNs in that category. The Government reserves the right to selectively qualify the offeror for each NSN in that category. For example, if a category has 10 NSNs but 1 of them is outside their capability, the Government reserves the right to say the offeror only successfully qualified for 9. After review, the Government will provide the offeror with the list of all the NSNs they are qualified to repair in that category and provide any rational if the offeror was not qualified for specific NSNs.
2. Qualify for Individual NSNs: If an offeror believes they are qualified for single NSNs in different categories, they can choose any from the full list of NSNs.
3. Perform combination of 1 & 2: For example, they can apply for qualification for Category 30 and they can qualify for individual NSNs that are outside of that category.
Offerors can apply for qualification for as many or as few NSNs as they choose.
As stated in the RQR, applying for qualification neither guarantees being successfully qualified nor guarantees a contract with the Government. All qualification is done at the expense of the offeror and the Government shall NOT reimburse offerors for qualification expense, regardless of if they are successful or unsuccessful.
Categories
1 Speed gear assembly 19 Transformers 2 Drive Motion gear 20 Arresters 3 Mechanical Fans 21 Coils 4 Compressor Dehydrator 22 Oscillators 5 Liquid storage tank 23 Tubes 6 Trigger Switching Unit 24 Radio and Antennas 7 Modulator Radars 25 Amplifiers 8 Radar Set Assemblies 26 Circuit cards 9 Control Transmitters 27 Motors 10 Processor Radar 28 Regulators 11 Exciter Radio Frequency 29 Phase shifters 12 Digital Computer 30 Power Supplies 13 Indicator Position 31 Meters 14 Control-Monitor 32 Control Computer 15 Generator Pulse 16 Electronic Synthesizers 17 Modulator Assemblies 18 Frequency Converters
P/N: [See Appendix A, Column C]
20 Aug 2025 Section C 2/4
SECTION C:
1. QUALIFICATION REQUIREMENTS THAT MUST BE SATISFIED TO BECOME A QUALIFIED SOURCE
a. Prequalification Notice: The offeror shall notify the appropriate Government Small Business Office (AFSC.OL.SB@us.af.mil) or, if responding to a solicitation, the Contracting Officer of their intent to qualify as a source for the item(s) [See Appendix A, Column D]. Offerers shall submit the Source Approval Request (SAR) package IAW AFMCI 23-113 and FAR 9.2 Qualification Requirements.
b. Facilities, Testing, and Inspection Capabilities: The offeror must certify to the Government that they have or have access to, the required facilities and equipment to repair, inspect, test, package, and store the item. The offeror shall make their facilities, equipment, tooling, and personnel available for evaluation and inspection by the Government.
c. Data Verification: The offeror must verify that they posses the complete and most current ESA approved Technical Data Package provided by the Government procuring office. This verification must include a complete list of all procedures, drawings, and specifications, including change notices, in the offeror’s possession including, at a minimum the drawings listed in Appendix A (Column F) with the associated cage code (Appendix A, Column G) for the NSN(s) the offeror wishes to apply for qualification to repair. The offeror may also be required to produce copies of all applicable procedures, drawings, or specifications.
d. Repair Process Verification: The offeror must repair this item to conform to the Government requirements as prescribed within the ESA-approved engineering/technical data package. The offeror must show compliance with Unique Identification (UID) requirements in accordance with DFARS 211.274 as prescribed within the ESA-approved engineering/technical data package. The offeror must provide, at their own expense, data showing the results of all quality, performance, and environmental evaluations conducted by the offeror to show compliance with the Government requirements as prescribed by 415 SCMS. The offeror shall also identify its sources for materials and its standards for internally used processes.
e. Test and Evaluation and/or Verification: The offeror, at their own expense, shall prepare and submit to 415 SCMS for their prior approval, a qualification test plan/procedure detailing how they intend to verify compliance with all performance, environmental, mechanical, and quality assurance requirements identified by the test drawings provided in Appendix A (Column H). If no test drawings are available, the offeror must create their own test plan(s)/procedures(s) that verify their capability to meet the requirements in the NSN drawings listed in Appendix A (Column F). A single test plan covering multiple NSN’s must be able to address how the offeror intends to verify compliance with all performance, environmental, mechanical, and quality assurance requirements identified by the test drawings covered by the test plan for those
P/N: [See Appendix A, Column C]
20 Aug 2025 Section C 3/4 multiple NSN’s. If a single test plan is unable to be adapted to cover multiple NSN’s, than separate test plans must be provided.
f. Qualification Requirement Cost Estimate: Estimated likely costs for testing and evaluation, which will be incurred by the potential offering party to become qualified are $10,000.00 per category.
g. Qualification Time Completion Estimate: It is the estimate of the engineering support activity that completion of this qualification effort should require 60 days per request. This is based on complexity of the [See Appendix A, Column D] and other factors.
h. Qualification Time Limitation: An offeror may not be denied the opportunity to submit and have considered an offer for a contract if the offeror can demonstrate to the satisfaction of the contracting officer that the offeror (or its product) meets these standards for qualification or can meet them before the closing date specified on the solicitation.
i. Evaluation of Proposals Not Previously Qualified: The offeror must be fully qualified in order to be eligible for a contract award. Therefore, the offeror must fulfill all of the requirements stated, or have a plan to fulfill all of the requirements, in writing, in the qualification requirement by the close of the solicitation. Once an offeror has demonstrated to the satisfaction of the contraction officer that the offeror (or its product) meets the standards for qualificaiton, the offeror will be listed as an approved repair source for the item(s). Approval, however, does not guarantee subsequent contract award.
P/N: [See Appendix A, Column C]
20 Aug 2025 Section C 4/4
2. SOURCE QUALIFICATION WAIVER REQUIREMENTS
Sources who meet any of the following Source Qualification Waiver Criteria (QWC) may apply for a waiver of all or part of the qualification requirements. If an offeror is able to show in a waiver request, that they are capable of repairing the whole category or multiple NSN’s in a category, a waiver for the entire categeory, or list of selected NSN’s may be waived. Offerors requesting multiple waivers must specify the NSNs for which they are requesting the waivers. If a waiver is granted and the offeror is awarded a contract, then the Government reserves the right to require the offeror to provide a post-contract award first article/articles exhibit to verify production capability:
a. QWC1: The potential source submits written certification that the articles have been supplied to the Government or original equipment manufacturer (e.g., DD Form 250, Material Inspection and Receiving Report, Purchase Order invoice, etc).
b. QWC2: The potential source is qualified on the right-hand article and requests to be qualified on the left-hand article. If the right-and left-hand articles are mirror images of each other, then approval may be given.
c. QWC3: A source qualified to provide an assembly is usually qualified to provide subassemblies, major components, and items of that assembly.
d. QWC4: A source qualified to provide earlier dash numbers of a basic P/N may be qualified to provide other dash numbers of that same basic P/N, provided there is no increase in complexity, criticality, or other relevant requirements.
e. QWC5: A source qualified to provide a similar or like item can be qualified to provide the required item. However, for approval, the engineering authority must verify that there is no increase in complexity, criticality, or other requirements over that of the similar item. At a minimum, the source shall provide a complete set of drawings for the similar item and written proof, such as purchase orders, shipping documents, etc., to show that the similar item was provided to the original equipment manufacturer or DoD. This waiver can be applied to multiple items or an entire category.
f. QWC6: A source previously qualified to provide an item, but which has been purchased, sold, merged, absorbed, reformed, split, etc., may qualify if it can be established that the qualification is currently with the requester and that the requester has the same or equivalent facilities, tooling, equipment, personnel, and utilizes the original forging, castings, etc., in the repair process.
APPENDIX A: LIST OF NSNS
Item
Item Group
NSN PN NOUN APPLICATION Mfr. Drawing (C.1.c.) CAGE Testing Drawing#
1 1 3010-01-315-5148 137474 SPEED GEAR
ASSEMBLY
MINI MUTES DWGS:
41519/120614/200927771
82152
2 2 3020-01-598-9451 134010-1 DRIVE
MOTION
GEAR
JTE T.O's: 43D7-19-5-4-WA-1, 43D7-19-7-4-WA-1
54547 134010-1
3 3 4140-01-569-6113 041295000 TUBEAXIAL
FAN
JTE T.O: 43D7-19-5-4-WA-1 85877 200532022
4 3 4140-01-598-6406 041296000 VANEAXIAL
FAN
JTE T.O: 43D7-19-5-4-WA-1 97424 A2500-100043
5 4 4440-01-097-6169 105150 COMPRESSOR
DEHYDRATOR
MUTES TO: 43D7-19-2-4, DWGS:
654VM2520
31068 654VM2520
6 5 5430-01-079-8076 353D663 TANK LIQUID
STORAGE
CRC T.O: 31P3-2TPS-2-2-WA-1 ,
31P3-2TPS-75-4-WA-1
97942
7 6 5840-01-075-9148 354D017G
TRIGGER
SWITCHING
UNIT
CRC TO: 31P3-2TPS75-4 DWGS:
354D017
48306
8 7 5840-01-090-2599 MACH14 MODULATOR
RADAR
MUTES TO: 43D7-19-2-4, DWGS:
654VE00062
3B150 654CE0006
9 7 5840-01-090-2600 MAXH12 MODULATOR
RADAR
MUTES TO: 43D7-19-2-4, DWGS:
654VE00062
3B150 Drawing
654VE00062
and 654CE0006
10 7 5840-01-090-5060 MAXH9 MODULATOR
RADAR
MUTES TO: 47D-19-2-4, DWGS:
654VE00062
3B150 654CE0006
11 7 5840-01-090-5061 MAKUH9 MODULATOR
RADAR
MUTES TO: 43D7-19-2-4, DWGS:
654VE0062
3B150 654CE0006
12 7 5840-01-090-9250 MACH8 MODULATOR
RADAR
MUTES TO: 43D7-19-3-4 , 43D7-
19-2-4 DWGS:
654VE00062
3B150 654CE0006
13 7 5840-01-285-4479 MAXH16 MODULATOR
RADAR
MUTES TO: 43D7-19-2-4, 43D7-
19-4-4, DWGS:
654VE00062
3B150 Technical Order 43D7-19-2-183, 654VE00062, 654CE0006, 654-AEI-AK-
4158 and associated engineering orders and drawings
14 8 5840-01-157-9335 1D18129G
RADAR SET
SUBASSEMBLY
CRC T.O: 31P3-2TPS-2-2-WA-1 ,
31P3-2TPS-75-4-WA-1
48306
15 8 5840-01-180-9215 586R539H0
RADAR SET
SUBASSEMBLY
CRC TO: 31P3-2TPS75-4 DWGS:
586R539, PDS22933,
09A11214-H
48306
16 8 5840-01-481-7460 1366840 RADAR SET
SUBASSEMBLY
CRC T.O: 31P3-2TPS-2-2-WA-1 ,
31P3-2TPS-75-4-WA-1
2F259
17 8 5840-01-483-0555 1366839 RADAR SET
SUBASSEMBLY
CRC T.O: 31P3-2TPS-2-2-WA-1 ,
31P3-2TPS-75-4-WA-1
2F259
18 9 5840-01-498-2679 3050772-
CONTROL
TRANSMITTER
MINI MUTES 43D7-19-4-4-1, DWGS:
3050772
66948
19 9 5840-01-498-3432 3050775-
CONTROL
TRANSMITTER
MINI MUTES 43D7-19-4-4, DWGS:
3050775
66948
20 10 5840-01-510-5640 3050770-
PROCESSOR
RADAR
MINI MUTES 43D7-19-4-4, DWGS:
3050770
66948
21 11 5840-01-538-6564 310377 EXCITER
RADIO
FREQUENCY
CRC TO: 31P3-2TPS75-4 DWGS:
310377
1PYQ1
22 12 5840-01-540-3604 3109280-
COMPUTER
DIGITAL
MUTES TO: 43D7-19-2-4, DWGS:
3109280
91417 TP3109280,
3109274 and referenced documents
23 13 5840-01-598-5782 201027859 -10
INDICATOR
POSITION
MUTES TO: 43D7-19-2-4, 43D7-
19-6-1, DWGS:
26401 DWGS:
201027859 and
TO 73D7-19-6-1
201027859, 201027863, 201027864
24 14 5895-01-069-8851 C-
9089/UPX
CONTROL-
MONITOR
CRC TO: 31P3-2TPS75-4 DWGS:
345D036
80058
25 15 5895-01-090-7494 1031675-1 GENERATOR
PULSE
MUTES TO: 43D7-19-2-4, DWGS:
654VE00061
3B150 Drawings
654VE00061
and 1031675
26 16 5895-01-097-3051 ASN-
103XAL-71
SYNTHESIZER
ELECTRONIC
MUTES TO: 43D7-19-2-4, DWGS:
654VE4840
60583 654VE4840
27 16 5895-01-097-6193 ASN-
117XAL-73
SYNTHESIZER
ELECTRONIC
MUTES TO: 43D7-19-2-4, DWGS:
654VE4840
60583 654VE4840
28 16 5895-01-097-6194 ASN-
119XAL-75
SYNTHESIZER
ELECTRONIC
MUTES TO: 43D7-19-2-4, DWGS:
654VE4840
60583 654VE4840
29 16 5895-01-097-6195 ASN-
430XAL-76
SYNTHESIZER
ELECTRONIC
MUTES TO: 43D7-19-2-4, DWGS:
654VE4840
60583 654VE4840
30 16 5895-01-105-5515 R-2379 SYNTHESIZER
ELECTRONIC
MUTES TO: 43D7-19-2-4, DWGS:
654VE4840
59926 654VE4840
31 16 5895-01-318-1786 6139-5280-
ELECTRICAL
SYNTHESIZER
MINI MUTES 43D7-19-4-4 33025
32 16 5895-01-528-4986 310615 ELECTRONIC
SYNTHESIZER
CRC TO: 31P3-2TPS75-4
DWGS: 310615
1PYQ1
33 17 5895-01-099-2785 654VE0011
-1
MODULATOR
SUBASSEMBLY
MUTES TO: 43D7-19-2-4, DWGS:
654VE0011
3Z966 Drawing
654VE0011
34 17 5895-01-099-2786 AU156 MODULATOR
SUBASSEMBLY
MUTES TO: 43D7-19-2-4, 43D7-
19-4-4, DWGS: 654VE0011
32324 Drawing
654VE0011
35 17 5895-01-106-3413 654E4600-
MODULATOR
SUBASSEMBLY
MUTES TO: 43D7-19-2-4, DWGS:
654E4660
81755 654AEI-AK-
4020B
36 17 5895-01-106-3414 654E4660-
MODULATOR
SUBASSEMBLY
MUTES TO: 43D7-19-2-4 DWGS:
654E4660
81755 Drawing 654E4660, to include all ECOs
37 18 5895-01-551-7103 D-97- 1.8/2.25
FREQUENCY
CONVERTER
GPS 31R2-2FRC178-4
AN/FRC-178
33592
38 18 5895-01-551-7107 RTL-
S200000
FREQUENCY
CONVERTER
GPS 31R2-2FRC178-4
AN/FRC-178
09SP4
39 19 5915-00-009-8251 343D393G
NETWORK
PULSE
CRC TO: 31P3-2TPS75-4 DWGS:
343D393
97942
40 20 5920-01-132-7482 ACP-1101-
ARRESTER
ELECTRICAL
MUTES TO: 43D7-19-2-44, DWGS:
ACP-1000
30992 ACP-1000
41 21 5950-00-023-8464 335D502G
COIL
ELECTRICAL
CRC T.O: 31P3-2TPS-2-2-WA-1 ,
31P3-2TPS-75-4-WA-1
97942
42 22 5955-01-097-3064 PC-0902M-
OSCILLATING
GROUP
MUTES TO: 43D7-19-2-4, DWGS:
654VE4851
OUTX6 654VE4851
43 22 5955-01-097-6222 PC-0901M-
OSCILLATING
GROUP
MUTES TO: 43D7-19-2-4, DWGS:
654VE4851
OUTX6 654VE4851
44 22 5955-01-097-6223 PC-2000A-
OSCILLATING
GROUP
MUTES TO: 43D7-19-2-4, DWGS:
654VE4851
OUTX6 654VE4851
45 22 5955-01-111-2101 10986201 OSCILLATING
GROUP
TRTG DRAWING NO. 10986201 1220 DRAWING NO.
10986201
46 23 5960-00-478-1167 SFD369 ELECTRON
TUBE
BAND SIM 43D7-11-21-4, DO43,
ENGINERING DATA
88236 CPI (CAGE
88236) Test
Specification, Doc No SFD-369
47 23 5960-01-082-8571 VMU-
1359GD
ELECTRON
TUBE
MUTES TO: 43D7-19-2-4 DWGS:
654VE00048
88236 654CE0004
48 23 5960-01-083-8989 VMC-
1360GD
ELECTRON
TUBE
MUTES TO: 43D7-19-2-4 DWGS:
654VE0044, 654VE0004
88236 654CE0004
49 23 5960-01-083-8990 LO0100U ELECTRON
TUBE
MUTES TO: 43D7-19-2-4, DWGS:
654VE00047, 654CE0004
89146 654CE0004
50 23 5960-01-084-7379 VMX-
1221GD
ELECTRON
TUBE
MUTES TO: 43D7-19-2-4, DWGS:
654VE00045, 654CE0004
88236 Drawing
654VE00045
and 654CE0004
51 23 5960-01-084-7380 VMC1223G
D
ELECTRON
TUBE
MUTES TO: 43D7-19-2-4, DWGS:
654CE0004, 654VE00042
88236 654CE0004
52 23 5960-01-086-6158 VMC-
1130GD
ELECTRON
TUBE
MUTES TO: 43D7-19-2-4, DWGS:
654VE00043, 654CE0004
88236 654CE0004
53 23 5960-01-090-9291 667090 ELECTRON
TUBE
TRTG
DRAWING NO. 667090
98255 DRAWING NO.
D7802
54 23 5960-01-307-2674 PM-250U ELECTRON
TUBE
UMTE under VMU-1724 in 43d7- 11-40-4-1
5W432 SC5985-0097
55 23 5960-01-391-1308 8811-2524-
ELECTRON
TUBE
UMTE 43d7-11-40-4-1 ;DWG:
8811-2524
12339 SC5985-0098
56 23 5960-01-526-3843 PM-800S ELECTRON
TUBE
UMTE 43d7-11-40-4-1 5W432 SC5985-0269
57 23 5960-01-550-2782 VMC-
1351D
ELECTRON
TUBE
UMTE 43d7-11-40-4-1 12115 SC5985-0278
58 24 5985-01-078-4682 3130 COUPLER
ROTARY
RADIO
MUTES TO: 43D7-19-2-4, DWGS:
626Z1117
25634 626Z1117
59 24 5985-01-081-5826 349D821G
REFLECTOR
ATENNA
CRC TO: 31P3-2TPS75-4 DWGS:
349D821, 200827954, 620A958, 349D821G01
48306
60 24 5985-01-081-8451 DAY-1356 COUPLER
ROTARY
RADIO
MUTES TO: 43D7-19-2-4, 43D7-
19-4-4, DWGS: 654VE0001
99200 TO 31P1-4-114-
61 24 5985-01-088-2118 AL132 SWITCH
RADIO
FREQUENCY
MUTES TO: 47D7-19-2-4, DWGS:
654VE7117
0DZK6 654VE7117
62 24 5985-01-097-6191 ASN-
117XAL-74
SYNTHESZIER
ELECTRIC
MUTES TO: 43D7-19-2-4, DWGS:
654VM2520
60583 654VE4851
63 24 5985-01-130-6667 200928246 SWITCH
RADIO
FREQUENCY
MUTES TO: 43D7-19-2-4, DWGS:
200928246
98747 20094851
64 24 5985-01-182-1118 155C303H0
ANTENNA CRC T.O: 31P3-2TPS-2-2-WA-1 ,
31P3-2TPS-75-4-WA-1
48306
65 24 5985-01-307-6290 8811-4900-
ANTENNA UMTE 43d7-11-40-4-1 12115
66 24 5985-01-623-4969 ED2672 COUPLER
ROTARY
RADIO
MUTES TO: 43D7-19-2-4 DWGS:
654VE0001
99932 Drawing 654VE0001 to include all ECOs 67 25 5996-00-572-1617 01-00022-
AMPLIFIER
SUBASSEMBLY
CRC T.O: 31P3-2TPS-2-2-WA-1 ,
31P3-2TPS-75-4-WA-1
0SKB3
68 25 5996-01-033-0197 317239 AMPLIFIER,
INTERMEDIAT
E
MILSATCOM/
SEON
TO 31M3-4-5-4 80045
69 25 5996-01-097-2439 TMA4506 AMPLIFIER
RADIO
FREQUENCY
MUTES TO: 43D7-19-3-4, DWSG:
654VE4838
0TXM0 654VE4838 and associated
Change Orders 70 25 5996-01-097-6225 01D1327-
AMPLIFIER
RADIO
FREQUENCY
MUTES TO: 43D7-19-2-4, DWGS:
654VE4849
4J945 654VE4849
71 25 5996-01-212-6280 APG-
4003M401
AMPLIFIER
RADIO
FREQUENCY
CRC TO: 31P3-2TPS75-4 24539
72 25 5996-01-315-4023 41535-101 AMPLIFIER
ELECTRONIC
MINI MUTES 36A11-21-16-1,DWGS:
41535
82152
73 25 5996-01-315-5140 41536-101 AMPLIFIER,
RADIO
FREQUENCY
MINI MUTES 36A11-21-16-1,DWGS:
41536
82152
74 25 5996-01-433-3730 9378602-
AMPLIFIER
ASSEMBLY
MWD DWGS: 11259445,
7376298, 7376299, 9378602, 9126591, 9126592
98747
75 25 5996-01-454-4605 DB060685-
TRIGGER
AMPLIFIER
SCS T.O. 31P1-2FPS85-22,
TCTO 31P1-2FPS85-601,
DWGS: 9477861
31196
76 25 5996-01-475-1564 01-30018-
AMPLIFIER
TRIGGER
CRC T.O: 31P3-2TPS-2-2-WA-1 ,
31P3-2TPS-75-4-WA-1
0SKB3
77 25 5996-01-482-3929 1366837 AMPLIFIER
RADIO
FREQUENCY
CRC TO: 31P3-2TPS75-4 DWGS:
1366837
2F259
78 25 5996-01-554-9882 MP-FLX-
230/X10B
AMPLIFIER
ELECTRONIC
MILSATCOM/
SEON
TO 31M3-4-5-4 0XDP7
79 25 5996-01-582-2793/ 5996-01-414-8364
80948434/ 11259552
AMPLIFIER
RADIO
MWD DWGS: 80948434/ T.O.
31P2-2FPQ16-06
12255/ 17773
80 26 5998-01-080-7949 654P5040-
CCA MUTES TO: 43D7-19-2-4, 43D7-
19-4-4, DWGS: 654P5040
81755 654P5040
81 26 5998-01-084-5083 654P5030-
CCA MUTES TO: 43D7-19-2-2, 43D7-
19-2-4, DWGS: 654P5030
81755 Drawing 654P5030, to include all ECOs 82 26 5998-01-120-2562 654P5064-
CCA MUTES TO: 43D7-19-2-4, DWGS:
654E5064 81755 Drawings
654P5064 and
654-AEI-4058
83 26 5998-01-293-9676 654P5416-
CCA MUTES TO: 43D7-19-2-4, DWGS:
654P5416
81755 654-AEI-AK-
84 26 5998-01-325-6234 DPM56DF4
-K7710
OSCILLATING
GROUP
MUTES TO: 31R2-4-950-4 and
DPM56DF4-K7710
46175 DPM56DF4-
K7710
85 26 5998-01-381-6724 654E4760-
ELECTRONIC
COMPONENT
MUTES TO: 43D7-19-4-4, DWGS:
654E4760
81755 654-AEI-AK-
4034and
654E4760 86 26 5998-01-491-0370 3050776-
ELECTRONIC
COMPONENT
MINI MUTES 43D7-19-4-4-1, DWGS:
3050776
66948
87 26 5998-01-491-3759 3050945-
CCA MUTES TO: 43D7-19-2-4, DWGS:
3050945
66948 16963-SSS-001,
16963-SSS-002,
16963-SSS-003
88 26 5998-01-491-4132 3050917-
CCA MINI MUTES 43D7-19-4-4-1, DWGS:
3050917
66948
89 26 5998-01-491-4133 3050774-
CCA MINI MUTES 43D7-19-4-4-1, DWGS:
3050774
66948
90 26 5998-01-498-4620 3050776-
CCA MINI MUTES 43D7-19-4-4, DWGS:
3050776
66948
91 26 5998-01-498-8206 3050945-
CCA MINI MUTES 43D7-19-4-4, DWGS:
3050945
66948
92 26 5998-01-498-8983 3050776-
ELECTRONIC
COMPONENT
MINI MUTES 43D7-19-4-4, DWGS:
3050776
66948
93 26 5998-01-510-5647 3050926-
CCA MINI MUTES 43D7-19-4-4, DWGS:
3050926
66948
94 26 5998-01-540-5204 201825252 -10
CCA MUTES TO: 43D7-19-2-4, DWGS:
201825252, 201718995
26401 201825263 test procedure, 201825256, 201718995
95 26 5998-01-650-6355 201309212 -10
CCA MUTES TO: 43D7-19-4-4-1, DWGS:
201309212
26401 201309214, 201309213
96 26 5998-01-651-2676 201309205 -10
CCA MINI MUTES 43D7-19-4-4, DWGS:
201309205
98747
97 26 5998-01-651-4973 201309198 -10
CCA MINI MUTES 43D7-19-4-4, DWGS:
201309198
98747
98 26 5998-01-672-2576 201718970 -70
CCA MUTES TO: 43D7-19-3-4-1, 43D7-
19-4-4-1, DWGS:
20171897020, 2007821, 20178985
98747 3051473, 201718991, 201718992
99 26 5998-01-673-3117 201718970 -50
ELECTRONIC
COMPONENT
MINI MUTES 43D7-19-4-4, DWGS:
201718970
98747
100 26 5998-01-673-3119 201718970 -90
CCA MINI MUTES 43D7-19-4-4, DWGS:
201718970
98747
101 26 5998-01-673-3993 201718970 -10
ELECTRONIC
COMPONENT
MINI MUTES 43D7-19-4-4-1, DWGS:
201718970
98747
102 26 5998-01-673-6506 201718970 -30
CCA Mini Mutes 43D7-19-4-4, DWGS:
201718970
98747
103 27 6105-01-306-8304 TTB3-2931-
3093BA
MOTOR
CONTROL
UMTE 43d7-11-40-4-1 ; DWG:
SC6105-0008
5W607 SC6105-0008
104 27 6105-01-315-0540 41479-1 MOTOR,
DIRECT
CURRENT
MINI MUTES 36A11-21-16-1, DWGS:
41479
82152
105 27 6105-01-341-0209 TTB3-2913-
3000-AA
MOTOR
DIRECT
CURRENT
UMTE 43d7-11-40-4-1; DWG:
SC6105-0008
5W607 SC6105-0008
106 27 6105-01-353-0959 8811-0771-
MOTOR
DIRECT
CURRENT
UMTE 43d7-11-40-4-1 DWG:
8811-0771-2
12115 SC6105-0008
107 27 6105-01-503-8585 TT42356-
3030-DA
MOTOR,
DIRECT
CURRENT
MINI MUTES 36A11-21-16-1, DWGS:
41491
11384
108 27 6105-01-555-8479 1185394 MOTOR
CONTROL
MILSATCOM/
SEON
TO 31M3-4-5-4 1Q601
109 27 6105-01-573-5924 495855-
MOTOR
CONTROL
MILSATCOM/
SEON
TO 31M3-4-5-4 1Q601
110 27 6105-01-598-5629 JTE133610-
MOTOR,
DIRECT
CURRENT
JTE T.O: 43D7-19-5-4-WA-1 54547 JTE133610
111 28 6110-00-879-9800 1571-9898 REGULATOR
VOLTAGE
MUTES TO: 35C1-5-4-1, DWGS:
650059
13850 1571-A Instruction
Manual 112 29 5915-01-186-7344 586R552H0
PHASE
SHIFTER
CRC TO: 31P3-2TPS75-4 DWGS:
586R552 48306
113 29 6125-00-838-7075 PM661942
PHASE
SHIFTER ASSY
SCS T.O. 31P1-2FPS85-22,
TCTO 31P1-2FPS85-601
6W037
114 30 6130-00-826-8284 336D468G
POWER
SUPPLY
CRC T.O: 31P3-2TPS-2-2-WA-1 ,
31P3-2TPS-75-4-WA-1
48306
115 30 6130-01-034-7237 PTM28-1-4 POWER
SUPPLY
SOON PTM28-1-4 3B150
116 30 6130-01-083-8528 654E4075-
MODULATOR
POWER
SUPPLY
MUTES TO: 43D7-19-2-4, DWGS:
645E4075
81755 Drawing 654E4075
117 30 6130-01-083-9776 654E4745-
POWER
SUPPLY
MUTES TO: 43D7-19-2-4, 43D7-
19-2-2 DWGS: 654E4745
81755 654VE4745 and
654-AEI-AK-
4131 ATP
118 30 6130-01-106-4261 654E4735-
POWER
SUPPLY
MUTES TO: 43D7-19-2-4, 43D7-
19-4-4, 43D7-19-4-4-1, DWGS: 654E4735
81755 654E4735
119 30 6130-01-369-3392 HS10-
C1022
POWER
SUPPLY
SBIRS TO: 31S1-2GKC1-171
Figure 2, Index 7, Drawing:
177877-102, 0D6P8 HS10-C1022
120 30 6130-01-504-0744 216714 POWER
SUPPLY
ASSEMBLY
SCS T.O. 31S1-2FSD3-52,
DWGS: 216714
0DKS7
121 30 6130-01-504-0745 216713 POWER
SUPPLY
ASSEMBLY
SCS T.O. 31S1-2FSD3-52,
DWGS: 216713
0DKS7
122 30 6130-01-511-3421 573870 POWER
SUPPLY
MUTES TO: 43D7-19-2-4, DWGS:
654E4703
26269 654-AEI-AK-
123 31 6625-01-491-5746 8541COPT0
WATTMETER MUTES TO: 43D7-19-2-4, 43D7-
19-4-4, DWGS: 2007819
58900 2007819
124 32 7042-01-599-2306 134025-1 CONTROL
COMPUTER
JTE T.O's: 43D7-19-7-4-WA-1 54547 134025-1
File details come from the government source that posted it. Updated .