This Statement of Work (SOW) details FEMA's Disaster Emergency Communications Division's requirement to acquire 15 vehicle-mounted generators for mobile command and control vehicles. Specifically, the agency needs 13 new 8kW and 2 new 12kW diesel generators from Cummins (or equivalent), which will replace 20-year-old generators that have exceeded their 10,000-hour life expectancy. The generators are critical for supporting FEMA Incident Support Teams and their federal, state, tribal, and local partners during emergency communications operations. Delivery is specified for three locations: Fort Worth, TX (5 generators), Frederick, MD (3 generators), and Thomasville, GA (7 generators), with a 120-day delivery timeline from contract award. The technical requirements mandate specific generator models that match power demands and vehicle compatibility, with the vendor required to provide warranty information upon delivery.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Questions-Responses.xlsx | XLSX spreadsheet | |
| COMBINED SYNOPSIS-70FB8025Q00000014.pdf | ||
| Attachment 3-BNJ Generator - Copy_Redacted.pdf | ||
| Attachment 2-Pricing Sheet.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Department of Homeland Security
Federal Emergency Management Agency
FY25 Vehicle Generator Replacement
Statement of Work (SOW)
I. Project Title:
FY25 Generator Replacements
II. Background:
FEMA Disaster Emergency Communications Division Program Office seeks the acquisition of (13) 8kw and (2) 12kw Generators mounted mobile command vehicles that are used by the Agency for vehicle mounted generators. The vehicles provide mobile command and control disaster emergency communications to FEMA Incident Support Teams and directly support FEMA’s Federal, State, Tribal, and Local partners in the field. These new generators will replace the existing 20-year-old generators, that have exceeded the 10,000-hour life expectancy from the manufacturer by 5,000 hours and are becoming unstable and unreliable in the field.
These new 8kw and 12kw are replacements for the current 7.5kw generators, which are no longer available and are the generators that are being installed in the new vehicle builds. They are the only diesel powered, mountable generator that is large enough to provide the power required to support the vehicles missions in the field, but small enough to fit into the very restricted compartments that house them.
III. Technical Requirements
The specific manufacturer and model numbers, provided below, must be selected to match requirements determined by the Disaster Emergency Communications Division-Tactical Emergency Communications Branch to ensure that power demands and compatibility with the vehicle is met:
• Manufacturer: Cummins or equivalent
• Model: 8kw: Commercial QD 8HDKAU-41934T or equivalent specs
12kw: Onan 12.0 CMQD12000 or equivalent specs
IV. Performance Period
The vendor shall deliver within 120-days from the date of actual contract award
V. Acceptance and warranty
The vendor shall provide warranty information as part of the delivery order.
VI. Delivery The vendor shall deliver the (13) new Cummins 8kw generators to the following locations within the specified time identified in section IV of this SOW:
Five (5) Generators to:
FEMA
Attn: Tim Smith 501 West Felix St, Bldg. #12 Fort Worth, Texas 76115
Two (2) Generator to:
FEMA
Attn: Robert Hakius 4420 Buckeystown Pike Frederick, MD 21704
Six (6) Generators to:
Attn: Tom Olley 434 S Pinetree Blvd Thomasville, GA 31792
The vendor shall deliver the (2) new Cummins 12kw generators to the following locations within the specified time identified in section IV of this SOW:
One (1) Generators to:
FEMA
Attn: Paul Johnson 434 S Pinetree Blvd Thomasville, GA 31792
One (1) Generators to:
Attn: Dennis George 4420 Buckeystown Pike Frederick, MD 21704
| FY25 Vehicle Generator Replacement |
| Statement of Work (SOW) |
| I. Project Title: |
| II. Background: |
| III. Technical Requirements |
| IV. Performance Period |
| V. Acceptance and warranty |
| VI. Delivery |
| Five (5) Generators to: |
| Two (2) Generator to: |
| Six (6) Generators to: |
| One (1) Generators to: |
| One (1) Generators to: |
File details come from the government source that posted it. Updated .