Attachment 1 - 23H Area Estimation Rev1.pdf
PDF 101 KB Posted
- Attached to
- Z2DA--512A5-25-003 Repair 23H Fire Damage
- Solicitation number
- 36C24525B0003
About this file
This file is a quantity estimation spreadsheet (Attachment 1) detailing repair areas for Building 23H at Perry Point VA Medical Center. It provides room-by-room measurements for flooring, drywall, ceiling tiles, paint, and wall base repairs across multiple floors. Specific quantities include carpet tile installations ranging from 28 to 252 square feet per room, luxury vinyl plank flooring requirements, drywall repairs including shaftliner systems at pipe shafts, ceiling tile replacements, and wall base installations measured in linear feet. The document includes special notes for matching existing materials and types, particularly for partial repairs. The spreadsheet covers work areas on the 1st, 2nd, 3rd, and 4th floors, with the most extensive repairs needed on the 4th floor in multiple office spaces (rooms 406-413).
The quantities provided are estimated amounts with a general note indicating that additional demolition and replacement may be necessary beyond the listed measurements. Key specifications include triple-layer drywall requirements for the 3rd floor corridor and complete wall base replacement in several rooms versus partial repairs that must match existing materials in other areas. The document serves as a supporting attachment to a larger solicitation for fire damage repairs at the VA facility.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 23H Perry Point Lead Survey Summary Report_11-14-2013.pdf | ||
| Amended Specs.pdf | ||
| 512A5-25-003 Construction RFIs Rev.1.pdf | ||
| 512A5-25-003 23H ACM Data.xlsx | XLSX spreadsheet | |
| PP-23H-2-First Floor.pdf | ||
| PP-23H-4-Third Floor.pdf | ||
| 36C24525B0003 0003.docx | DOCX document | |
| PP-23H-5-Fourth Floor.pdf | ||
| PP-23H-3-Second Floor.pdf | ||
| DryingReport_Nov-15-2024.pdf | ||
| 36C24525B0003 0002.docx | DOCX document | |
| 512A5-25-003 23H Fire Damage Repairs SOW Rev2 - Amend 0002 -02112025.pdf | ||
| 512A5-25-003 Construction Visit Roster.pdf | ||
| RFI Form.xlsx | XLSX spreadsheet | |
| 36C24525B0003 0001.docx | DOCX document | |
| Wage Determination MD20250049.pdf | ||
| Attachment 3 - 512A5-25-003 Combined Specs Rev1.pdf | ||
| 36C24525B0003_1.docx | DOCX document | |
| Parking Location for 23H Site Visit.pdf | ||
| Attachment 2 - 23H Floor Plans.pdf |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 1 ‐ Building 23H Repairs Estimated Quantities
Rooms Flooring (ft2) CT: Carpet Tile
LVT: Vinyl Plank
Drywall (ft ) Ceiling Tile (ft
) Paint (ft
) Wall Base (ft)
1st Floor:
1G‐106 124 (CT) 45 8 255
c 47 b
1G‐108 ‐‐ 170 d
40 265 c 51 c
2nd Floor:
Corridor ‐‐ 20 a
‐‐ 320 c c
224 ‐‐ 30 16 175 c c
225 ‐‐ 80 8 265 c c
226 ‐‐ 15 16 325 c c
227 ‐‐ 130 d
8 340 c c
3rd Floor:
Corridor ‐‐ a
(TRIPLE LAYER) ‐‐ 250 c 15 c
323 ‐‐ 105 d
88 560 c 5 c
4th Floor:
Elevator Lobby ‐‐ ‐‐ 184 ‐‐ ‐‐
Corridor @ Suite 252 (LVP) 200 a 252 550 50 b
Closet 410 28 (CT) 30 28 140 15 b
406 112 (CT) 110 112 440 45
b
407 128 (CT) 140 128 440 45
b
408 128 (CT) 160 128 430 45
b
409 116 (CT) 200
d
116 430 45 b
411 128 (CT) 45 128 430 45
b
412 128 (CT) 45 128 430 45
b
413 252 (CT) 65 252 640 65 b a Drywall thickness shall match adjacent wall surfaces b Replace entire wall base in room c Partial Repair ‐ Match existing type and color adjacent to repaired location d At pipe shaft provide new shaft‐liner system (CH studs, Gypsum Liner Panels, and Finish Drywall)
GENERAL NOTE: The above areas are an estimation of required materials. Additional demolition and replacement of existing materials may be necessary to fully repair areas.
File details come from the government source that posted it. Updated .