This federal solicitation seeks to remove and replace multiple overhead doors at facilities on Eielson Air Force Base in Alaska. The contractor shall demolish existing fabric and metal doors and associated controls, conduit, and electrical fixtures before providing and installing all new doors and ancillary mounting and controls. A site visit will be held on July 21, 2022 for up to two attendees per prime contractor. Questions are due by July 26, 2022 with answers provided in an amendment. Electronic bids only must be submitted to the contracting officer and contract specialist by August 16, 2022. The NAICS code is 236220 with a small business size standard of $39.5 million. The magnitude is estimated between $1 million to $5 million. Payment and performance bonds are required. The period of performance is 225 calendar days from notice to proceed.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment FA500422B00090003 SF 30.pdf | ||
| Site Visit Questions and Answers (High Speed Overhead Doors) Updated.pdf | ||
| FTQW 20-1011 Questions and Answers - High Speed Overhead Doors.pdf | ||
| FTQW 20-1011 Site Visit Sign In Sheet.pdf | ||
| Solicitation Amendment FA500422B00090002 SF 30.pdf | ||
| Solicitation Amendment FA500422B00090001 SF 30.pdf | ||
| Attachment 05 - Submittal Register.xlsx | XLSX spreadsheet | |
| Attachment 04 - Wage Determination AK20220001.pdf | ||
| Attachment 01 - HS OH Door Replacement Statement of Work.pdf | ||
| Solicitation - FA500422B0009.pdf | ||
| Attachment 02 - Specifications.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bldg Num Location Bldg Name Door Size Brand Style Rollers Operator Manufacturer Model Capacity Condition XP class Notes 6203-3 W side S end W CHPP (Thaw Shed) 15'2"x17' Thermalcore 591 3" Sidemount L Overhead Door "L" Exp Proof 115V/.75hp Medium Class 2 / Div 1 / Group F 6203-4 W side S end E CHPP (Thaw Shed) 15'2"x17' Thermalcore 591 3" Sidemount R Overhead Door "L" Exp Proof 115V/.75hp Medium Class 2 / Div 1 / Group F 6203-5 W side N end W CHPP (Thaw Shed) 15'2"x17' Thermalcore 591 3" Sidemount R Overhead Door "L" 115V/.75hp Medium 6203-6 W side N end E CHPP (Thaw Shed) 15'2"x17' Thermalcore 592 3" Sidemount L Overhead Door "L" 115V/.75hp Medium 6203-1 W side S CHPP (Ash Shed) 16'x12' Thermalcore 591 3" Centermount Overhead Door "L" 115V/.75hp Medium 6203-2 W side N CHPP (Ash Shed) 16'x12' Thermalcore 591 3" Centermount Overhead Door "L" 115V/.75hp Medium 1306-1 S side W "A" AGE storage (Jack's House) 14'2"x14' Thermalcore 592 3" Sidemount L Overhead Door RSX 115V/.5hp High
1306-2 S side E "B" AGE storage (Jack's House) 14'2"x14' Thermalcore 592 3" Sidemount L Liftmaster H5011L3R 115V/.5hp High
4105-2 E side N Snow Barn 24'2"x18' Thermalcore 591 3" Sidemount L Overhead Door "L" 230V/3ph/.75hp Medium 4105-6 W side N Snow Barn 24'2"x18' Thermalcore 591 3" Sidemount L Liftmaster H1033ML 230V/3ph/.75hp Medium 4105-5 W side S Snow Barn 24'2"x18' Thermalcore 591 3" Sidemount R Raynor RGJH123-SR-2 230V/3ph/.75hp Medium 4105-3 E side S Snow Barn 24'2"x18' Thermalcore 591 3" Sidemount L Raynor RGJH123-SR-2 230V/3ph/.75hp Medium
HSC replacement