This Statement of Work (SOW) details a security upgrade project for the Pagosa Ranger District (RD) Office in Pagosa Springs, Colorado. The primary objective is to enhance building security by installing new walls and security doors with Lenel card readers to separate the public lobby and Visitor Information Services (VIS) area from employee spaces. Base contract requirements include constructing 1-hour rated walls, installing two security doors with card readers, integrating the doors into the existing Lenel security system, performing necessary electrical work, and implementing a remote front door locking mechanism.

Optional items include additional electrical work and installing four security cameras - three exterior and one interior. The project requires the contractor to supply all labor, materials, equipment, and necessary licenses, including a valid Colorado Electrical License. Contractors must comply with current building codes such as the International Building Code, International Fire Code, and National Electrical Code. Deliverables include a proposed project plan, contractor licensures, as-built drawings, and warranty documentation. The pre-bid conference is scheduled for March 27, 2025, at the project site, with deliverables due within five business days after contract award or completion of final walkthrough.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work (SOW) – Pagosa Ranger District (RD) Security Upgrade

San Juan National Forest Pagosa Springs, CO

Project Location:

180 Pagosa Street

Pagosa Springs, CO 81147

Archuleta County

Scope of Contract Background

The Pagosa Ranger District (RD) Office located in Pagosa Springs, CO was built in the late 1960’s and recently remodeled in 2018. Due to increased recreation in the area, the Pagosa RD Office has seen a significant uptick in visitation each year. The main lobby of the building is used as a public space for community members to collect information about recreational activities, learn about the

CONTRACT #: TBD Pagosa Ranger District (RD) Security Upgrade San Juan National Forest public lands in the area, and shop for Forest Service merchandise such as t-shirts, hats, gifts, etc.

The current design of the lobby opens directly to the rest of the building without a door separating the public from government employees, which poses a large risk to government employees and government property. The proposed project will help address this issue by installing several new walls and security doors with Lenel card readers that separate the main lobby and Visitor Information Services (VIS) area from the rest of the building. If funding allows, various optional items will be awarded to the Contractor. Optional items include installing several security cameras around the building, installing an additional Lenel card reader for the front door, and installing a remote lock for the front door.

Lobby Remodel and Security Upgrades

BASE ITEMS

1. Line Item 1.1 – 1-Hour Rated Walls (Lobby/VIS Area) – BASE

The base item interior walls will be located as outlined in the attached Drawing Set 1 – USFS Site and Details and rated for 1-hour. The sill plate will be secured to the subfloor and the top plate will be secured to the underside of the roof trusses. Demolition of the ceiling and floor tile will occur as required. One wall will be installed at the western entrance of VIS area from the main hallway to close it off to the rest of the building (the east entrance will be the only employee entrance to the VIS area). The other wall will be located on the north end of the lobby and will contain a security door. All walls must be insulated to provide an adequate sound barrier, must match the existing walls in the building, and must follow the specifications outlined in the codes listed in the Contractor Requirements section of this SOW. The Contractor is required to verify all dimensions in field and build walls to the existing ceiling height. See Drawing Set 1 – USFS Site and Details for more information.

2. Line Item 1.2 – 1-Hour Rated Security Doors (2 Total) – BASE

The two (2) interior security doors (3’ x 7’) must match the existing door material throughout the building, come equipped with security glass (wirelite), and have a 20-minute rating. The doors must also utilize accessible lever-style handles, push bars, and hydraulic door closers to match throughout building and swing as outlined in the attached Drawing Set 1 – USFS Site and Details.

3. Line Item 1.3 – Security Integration – BASE

The two (2) security doors will each need to contain a security card scanner that will be integrated to the existing Lenel security system of the building. See the Lenel System Integration section of this SOW for a description on the system specifics. Each security door must also come equipped with a door sensor for employees going into the lobby or VIS area from the main portion of the building. All doors must follow the specifications outlined in the codes listed in the Contractor Requirements section of this SOW. The cables for the main lobby lighting and the existing security door card readers run directly west from the security room (located in the downstairs electrical room) to the west wall, then run upward through a conduit to the main floor drop tile ceiling. From there, the cables run directly west along the main hallway. The Contractor will be required to run new security cables for the 2 new Lenel card readers within the same drop ceiling. Hard copy detailed schematics of the electronics of the building are located within the downstairs electrical room. See Drawing Set 1 – USFS Site and Details for more information.

4. Line Item 1.4 – Demolition of Ceiling Tiles/Flooring – BASE

The Contractor is required to demolish all necessary ceiling tiles and flooring to install the walls and doors. The Contractor will be responsible to remove all unused material from the site. If excess demolition material is expected, the Contractor must supply their own dumpster and use of USFS trash receptables will be prohibited. The Contractor will be allowed to place a dumpster on the west side of the building in the customer parking area for the duration of the project. See Drawing Set 1 – USFS Site and Details for more information.

5. Line Item 1.5 – Electrical – BASE

The Contractor will be responsible for supplying all the necessary wiring, connections, and labor to properly install two (2) new Lenel card readers and two (2) door sensors. See Drawing Set 1 – USFS Site and Details for more information on the existing layout of the electrical components of the building. Electrical work must follow the specifications outlined in codes listed in the Contractor Requirements section of this SOW.

6. Line Item 1.6 – Remote Lock – BASE

The Contractor must provide an electronic locking mechanism for the front door that can be remotely triggered from the front desk in case of emergency situations. The Contractor must work with the COR to select appropriate lock. See Drawing Set 1 – USFS Site and Details for more information.

7. Line Item 1.7 – Additional Lenel Card Reader – BASE

The Contractor must install an additional Lenel card reader for the front entrance and tie into existing Lenel security system. See Drawing Set 1 – USFS Site and Details for more information.

OPTIONAL ITEMS

8. Line Item 1.8 – Additional Electrical Work – OPTIONAL

The Contractor will be responsible for supplying all the necessary wiring, breakers, connections, and labor to properly install all electrical components of the contract (security cameras, remote lock, etc.). See Drawing Set 1 – USFS Site and Details for more information on the existing layout of the electrical components of the building. Electrical work must follow the specifications outlined in codes listed in the Contractor Requirements section of this SOW.

9. Line Item 1.9 – Security Cameras and Installation (4 Cameras) – OPTIONAL

Four (4) security cameras will be installed to the building; three (3) cameras will be located on the exterior of the building, while one (1) will be located within the front lobby. For the exterior cameras, one (1) will face south near the front entrance of the building, one (1) will face northwest between the two employee entrances in the courtyard, and one (1) will face directly north above the second story entrance (also in the courtyard). The security cameras will need to be wide angled, protected, and combined with a monitoring system for the front desk personnel and controls installed in the server room. The monitoring system must be compatible for existing USFS computers or other electronic devices (such as an iPhone or tablet). If it is not feasible to connect to the existing USFS system, the Contractor must work with the COR to find a location for separate camera monitors to be installed. See Drawing Set 1 – USFS Site and Details for more information.

Site Photos

Photo 1 - Front Entrance – Camera (OPTIONAL)

Photo 2 - Front Door

Photo 4 – Lobby (Facing West)

Photo 3 – Lobby ( Facin g North)

Photo 5 – VIS Area

Photo 6 – Northern Employee Entrance – Camera (OPTIONAL)

Photo 7 – Second Floor Employee Entrance – Camera (OPTIONAL)

Photo 8 – Lenel Security System Panel

Directions to Site

The site is located in the town of Pagosa Springs, CO. From the center of Main Street in Pagosa Springs, go east on US-160 (Main Street) for approximately 0.6 miles. The office building will be on the left-hand side of the road. The site coordinates are 37.269087303790556,

107.0048722195328 and the address of the building is 180 Pagosa Street, Pagosa Springs, CO, 81147. See figure below for general directions to the site from Pagosa Springs, CO.

Figure 1: Pagosa Springs to Pagosa RD Office

Lenel System Integration

1. System Component Standards:

The Contractor must ensure that the components installed are compatible with the following standards:

1) Policy Standards:

o Homeland Security Presidential Directive, HSPD-12.

o Federal Information Processing Standards Publication: Personal Identity Verification (PIV) of Federal Employees and Contractors, FIPS-201.

o National Institute of Standards and Technology”: Interfaces for Personal Identity

Verification, NIST SP800-73

2) Technology Standards:

o Microprocessor contract “chip”: Comply with ISO 7816 o Contactless card and reader: Comply with ISO 14443A-4 “Milfare DESFire data encryption

(13.56MHz).

2. Contractor Requirements:

Pagosa RD Office – 180 Pagosa St., Pagosa

Springs, CO, 81147

Main St. – Pagosa Springs, CO

1) Personal Identity Verification of Contractor Personnel

The Contractor shall be responsible for ensuring compliance by its employees with all applicable federal regulations, to include those of GSA, NIST, USDA and HSPD-12. Contractors and their employees are subject to all Federal laws applicable to Government installations and are under the jurisdiction of the Federal Protective Service (FPS). The COR or other designated program/project officers, in conjunction with the USDA HSPD-12 staff, will assist the Contractor in processing the required Security Background Investigations/Clearances.

o The Contractor shall comply with the personal identity verification (PIV) policies and procedures established by Department of Agriculture (USDA) Directives 4600 series. o Should the results of the PIV process require the exclusion of a contractor’s employee; the contracting officer will notify the contractor in writing. Contractor has 30-days to replace the employee. o The Contractor must appoint a representative to manage this activity and to maintain a list of employees eligible for a USDA PIV ID Badge required for performance of the work.

o The responsibility of maintaining a sufficient workforce remains with the Contractor.

o Employees may be barred by the Government from performance of the work should they be found ineligible or to have lost eligibility for a USDA PIV ID Badge. Failure to maintain a sufficient workforce of employees eligible for a USDA PIV ID Badge may be grounds for termination of the contract.

o The Contractor shall insert this clause in all subcontracts when the subcontractor is required to have access to a federally controlled facility or information system.

o The PIV Sponsor for this contract is the COR unless otherwise specified in this contract.

o The Government shall notify the Contractor if there is a change in the PIV Sponsor, the office address, or the office hours for registration.

At this time, the Government will pay for, and process all required security investigations and clearances, except as identified differently within this clause. The Contractor should be aware of any of its employees possibly having had a background investigation through another government agency. The investigation that was conducted, if verifiable by the USDA HSPD-12 staff and if it was completed within the last 5 years can be accepted by the Government in lieu of a background check. The Contractor shall comply with any facility badging requirements for the issuance of building access, badges, etc. and:

o Ensure that each of the Contractor’s employees has been issued either a temporary or permanent badge from the Government. A permanent badge will not be issued until the security questionnaire has been completed and favorably reviewed. o Temporary or visitor badges will be provided for persons who are identified as having an infrequent or temporary legitimate business need for access to the site.

o As noted above, periods that exceed 180 days will require a permanent badge.

o The badge must be worn at all times while in the facility. It must be displayed above the waist. The individual will retain possession of the badge as long as continued admittance to the site is needed.

o Ensure the safekeeping, wearing, and visibility of Government furnished badges.

o Immediately return all badges and permits to the Government when such need ceases to exist.

o The Contractor shall comply with any facility security requirements for access to the facility.

o The Contractor shall comply with all applicable rules governing parking at USDA locations.

2) IT Security Training

The Contractor and other external organizations will ensure that its employees performing under this contract fulfill all USDA requirements for mandatory security awareness and role-based advanced security training in accordance with OMB Circular A-130, FISMA, and NIST requirements, and sign all applicable USDA statements of responsibilities.

3) Physical Security

Contractor custody of sensitive information must be protected under The Privacy Act of 1974, 5 U.S.C. § 552a -- as amended. The Contractor shall be responsible for safeguarding Personally Identifiable Information (PII) data against unauthorized disclosure, dissemination, or modification in accordance with the requirements, law and USDA PII policy and regulations. This shall include but is not limited to: Privacy and PII data located in IT Systems, software, research data / information, personnel (institutional knowledge) and buildings/offices. All Contractor Personnel who work at USDA must be US Citizens and obtain approval for facility access.

4) Privacy Act

The Contractor Agrees To – o Comply with the Privacy Act of 1974 (the Act) and the agency rules and regulations issued under the Act in the design, development, or operation of any system of records on individuals to accomplish an agency function when the contract specifically identifies— o The systems of records; and the design, development, or operation work that the contractor is to perform.

o Include the Privacy Act notification contained in this contract in every solicitation and resulting subcontract and in every subcontract awarded without a solicitation, when the work statement in the proposed subcontract requires the redesign, development, or operation of a system of records on individuals that is subject to the Act; and o Include this clause, including this paragraph (3), in all subcontracts awarded under this contract, which requires the design, development, or operation of such a system of records.

o In the event of violations of the Act, a civil action may be brought against the agency involved when the violation concerns the design, development, or operation of a system of records on individuals to accomplish an agency function, and criminal penalties may be imposed upon the officers or employees of the agency when the violation concerns the operation of a system of records on individuals to accomplish an agency function. For purposes of the Act, when the contract is for the operation of a system of records on individuals to accomplish an agency function, the Contractor is considered to be an employee of the agency.

3. Clause Definitions:

a. “Operation of a system of records,” as used in this clause, means performance of any of the activities associated with maintaining the system of records, including the collection, use, and dissemination of records.

b. “Record,” as used in this clause, means any item, collection, or grouping of information about an individual that is maintained by an agency, including, but not limited to, education, financial transactions, medical history, and criminal or employment history and that contains the person’s name, or the identifying number, symbol, or other identifying particular assigned to the individual, such as a fingerprint or voiceprint or a photograph.

Obtain Contracting Officer Representative (COR) approval of any full electoral power outages necessitated by repairs 24 hours prior to shut down.

All buildings shall remain secure throughout repairs except for when necessitated. Systems should only be down during the repairs, lasting no more than half a day.

Contractor Requirements

The project requires the contractor to be responsible for supplying all labor, materials, equipment, miscellaneous items, freight, delivery, and all necessary valid licenses and permits required to complete work identified in this Contract. This includes possessing a valid Electrical License in the state of Colorado.

The Contractor is responsible to comply with the most current of the following codes during construction: o High Performance Sustainable Building (HPSB) o International Building Code (IBC) o International Fire Code (IFC) o International Green Construction Code (IGCC) o National Electrical Code (NEC)

The Contractor must follow all requirements set forth in the attached 3.2 – FS Specifications and must work with COR when questions arise regarding the Drawings and Specs.

Pre-Bid/Pre-Proposal Conference General Info

The Government is planning a pre-bid conference, during which potential offerors may obtain a better understanding of the work required. Offerors are encouraged to submit all questions in writing at least five (5) days prior to the conference. Questions will be considered at any time prior to or during the conference; however, offerors will be asked to confirm verbal questions in writing. After the conference, an amendment to the solicitation containing an abstract of the questions and answers, and a list of attendees, will be disseminated.

To facilitate conference preparations, it is requested that the person named on the Standard Form 1449 of this solicitation be contacted and advised of the number of persons who will attend. The Government assumes no responsibility for any expense incurred by an offeror prior to contract award.

Offerors are cautioned that, notwithstanding any remarks or clarifications given at the conference, all terms and conditions of the solicitation remain unchanged unless they are changed by amendment to the solicitation. If the answers to conference questions, or any solicitation amendment, create ambiguities, it is the responsibility of the offeror to seek clarification prior to submitting an offer.

Location of Conference

Date:

Time: 10:00 am – 11:00am. MST Location: 180 Pagosa Street, Pagosa Springs, CO 81147

Deliverables Deliverable Objective/Description Due by

Proposed Project Plan

Defining the responsibilities, timeline, risks, inspections, and milestones of contract objectives.

No later than five (5) business days after contract award.

Contractor Licensures

Provide all necessary licensures (electrical, Lenel VAR, and general contractors license) to the COR.

No later than five (5) business days after contract award.

As Built Drawings Outline new building layout in a concise, professional manner. Include descriptions of materials installed and dimensions.

No later than five (5) business days after final walkthrough is complete.

Warranty Items Provide the USFS with any warranty paperwork pertinent to products installed and work completed (Lenel card readers, door hardware, security cameras, door lock, general labor, etc.)

No later than five (5) business days after final walkthrough is complete.

For this contract, there will be NO government furnished materials.

March 27, 2025

Scope of Contract
Background
BASE ITEMS
1. Line Item 1.1 – 1‐Hour Rated Walls (Lobby/VIS Area) – BASE
2. Line Item 1.2 – 1‐Hour Rated Security Doors (2 Total) – BASE
3. Line Item 1.3 – Security Integration – BASE
4. Line Item 1.4 – Demolition of Ceiling Tiles/Flooring – BASE
5. Line Item 1.5 – Electrical – BASE
6. Line Item 1.6 – Remote Lock – BASE
7. Line Item 1.7 – Additional Lenel Card Reader – BASE
OPTIONAL ITEMS
8. Line Item 1.8 – Additional Electrical Work – OPTIONAL
9. Line Item 1.9 – Security Cameras and Installation (4 Cameras) – OPTIONAL
Site Photos
Directions to Site
Lenel System Integration
1) Personal Identity Verification of Contractor Personnel
2) IT Security Training
3) Physical Security
4) Privacy Act

Contractor Requirements