Attachment 02 Element 2 - Sample TO info 5 Aug 26.docx

DOCX document 376 KB Posted

Attached to
Technical and Programmatic Support Services (TPSS) III IDIQ MATOC
Solicitation number
PANHES-24-P-0000-003867
Issued by

About this file

This is a sample task order attachment that provides facility specifications for a cybersecurity systems implementation project. The document describes a 13,500 square foot facility that houses a Category II Arms room, evidence storage, and Headend Operations, requiring implementation of three Electronic Security Systems (ESS): Intrusion Detection System (IDS), Access Control System (ACS), and Video Surveillance System (VSS). Room 1 contains a Category II Arms room with weapons that currently lacks IDS coverage and requires constant armed guard surveillance. Room 2 is an Evidence Room requiring IDS protection based on risk assessment results, currently protected by a chain link wire mesh cage extending from floor to ceiling and across the top below the drop ceiling. Room 3 serves as the monitoring location for existing ESS infrastructure, though for purposes of this scenario, existing systems cannot be reused.

This attachment supports a U.S. Army Corps of Engineers Huntsville Center (CEHNC) Request for Information (RFI) for the Technical and Programmatic Support Services (TPSS) III IDIQ MATOC contract opportunity (Solicitation Number: PANHES-24-P-0000-003867). The RFI seeks contractor feedback on anticipated requirements for cybersecurity project oversight, implementation criteria across multiple agencies, and inventories of Facility-Related Control Systems (FRCS) including medical systems. Interested contractors must submit questions and suggestions in MS Excel format (Column A only, one item per row) to CEHNC-TPSS3@usace.army.mil by August 17, 2026, at 9:00 AM CT. This RFI is for information and planning purposes only and does not constitute a commitment to issue a future RFP.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 1

Factor 1: Technical Solution, Element 1, Sample Task Order

1.0 Description of facility: This 13,500 square foot facility houses a Category II Arms room, evidence storage, and Headend Operations.

2.0 Areas requiring ESS – Intrusion Detection System (IDS), Access Control System (ACS), and Video Surveillance System (VSS):

a. Room 1 contains a Category II Arms room with all weapons. There is currently no IDS coverage for this Arms room, and it requires constant surveillance by armed guards.

b. Room 2 is an Evidence Room that requires IDS protection based on the results of a risk assessment. The room currently has a chain link wire mesh cage from floor to ceiling (including coverage across the top) below the drop ceiling.

c. Room 3 is the monitoring location of the existing ESS. However, for the purpose of this hypothetical scenario, assume the existing can’t be reused.