Attachment 02 - Drawings EHRM - 554-21-700.pdf

PDF 33 MB Posted

Attached to
Z1DA--554-21-700 - EHRM Infrastructure Upgrades (Const) Denver, CO (PCAC) (VA-22-00042625)
Solicitation number
36C77622B0051
Issued by

About this file

This document provides details for a federal solicitation opportunity for infrastructure upgrades at the Denver VA Medical Center.

Solicitation number 36C77622B0051 seeks construction services for EHRM infrastructure upgrades at the Denver VA Medical Center, as described in the attached statement of work. The opportunity was issued by the Department of Veterans Affairs Technology Acquisition Center in Austin, with responses due by April 22, 2022. Interested parties should review the statement of work in Attachment 02 for the specific products and services required. The award is expected to be a firm-fixed-price construction contract to the responsive bidder whose proposal conforms to the solicitation and offers the best overall value to the government.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DENVER EHRM INFRASTRUCTURE UPGRADES

EASTERN COLORADO VA MEDICAL CENTER

1700 N. Wheeling Street

Aurora, CO 80045

Project No.: VA 554-21-700

SHEET LIST

G 0.0 COVER SHEET

10-CBS A 1.0 FIRST FLOOR ARCHITECTURAL DEMOLITION AND PLAN

10-CBS A 1.1 SECOND FLOOR ARCHITECTURAL DEMOLITION

10-CBS A 1.2 THIRD FLOOR ARCHITECTURAL DEMOLITION

10-CBS A 1.3 FOURTH FLOOR ARCHITECTURAL DEMOLITION

10-CBS M 0.0 MECHANICAL COVER SHEET

10-CBS M 0.1 MECHANICAL SCHEDULES AND DETAILS

10-CBS M 1.0 FIRST FLOOR MECHANICAL DEMOLITION

10-CBS M 1.1 SECOND FLOOR MECHANICAL DEMOLITION

10-CBS M 1.2 THIRD FLOOR MECHANICAL DEMOLITION

10-CBS M 1.3 FOURTH FLOOR MECHANICAL DEMOLITION

10-CBS M 1.4 FIRST FLOOR MECHANICAL PLAN

10-CBS M 1.5 SECOND FLOOR MECHANICAL PLAN

10-CBS M 1.6 THIRD FLOOR MECHANICAL PLAN

10-CBS M 1.7 FOURTH FLOOR MECHANICAL PLAN

E1.0 ELECTRICAL COVER SHEET

1-CON E1.1 CONCOURSE BUILDING C (CON) WAN/FIBER REVISIONS

1-CON E1.2 CONCOURSE BUILDING C (CON) WAN/FIBER REVISIONS

1-CON E1.3 CONCOURSE BUILDING C (CON) FIBER DEMOLITION AND PLAN

2-RES E1.1 RESEARCH BUILDING B (RES) LEVEL 3 WAN/FIBER REVISIONS

3-DAT S E1.1 DIAGNOSTIC & TESTING BUILDING D (DAT SOUTH) LEVEL SV & 1 WAN/FIBER REVISIONS

3-DAT S E1.2 DIAGNOSTIC & TESTING BUILDING D (DAT SOUTH) LEVEL 2 & 3 WAN/FIBER REVISIONS

3-DAT N E1.1 DIAGNOSTIC & TESTING BUILDING D (DAT NORTH) LEVEL SV & 1 WAN/FIBER REVISIONS

3-DAT N E1.2 DIAGNOSTIC & TESTING BUILDING D (DAT NORTH) LEVEL 2 & 3 WAN/FIBER REVISIONS

4-IBS E1.1 INPATIENT BUILDING SOUTH (IBS) LEVEL SV & 1 WAN/FIBER REVISIONS

4-IBS E1.2 INPATIENT BUILDING SOUTH (IBS) LEVEL 2 & 3 WAN/FIBER REVISIONS

5-IBN E1.1 INPATIENT BUILDING NORTH (IBN) LEVEL SV & 1 WAN/FIBER REVISIONS

5-IBN E1.2 INPATIENT BUILDING NORTH (IBN) LEVEL 2 & 3 WAN/FIBER REVISIONS

6-ENC E1.1 ENERGY CENTER BUILDING BUILDING L (ENC) LEVEL 1 WAN/FIBER REVISIONS

8-CBN E1.1 CLINIC BUILDING NORTH (CBN) LEVEL 1 WAN/FIBER REVISIONS

8-CBN E1.2 CLINIC BUILDING NORTH (CBN) LEVEL 2 & 3 WAN/FIBER REVISIONS

8-CBN E1.3 CLINIC BUILDING NORTH (CBN) LEVEL PH WAN/FIBER REVISIONS

9-CBC E1.1 CLINIC BUILDING CENTRAL (CBC) LEVEL 1 & 2 WAN/FIBER REVISIONS

9-CBC E1.2 CLINIC BUILDING CENTRAL (CBC) LEVEL 3 WAN/FIBER REVISIONS

10-CBS E1.1 CLINIC BUILDING A SOUTH (CBS) LEVEL 1 & 2 WAN/FIBER REVISIONS

10-CBS E1.2 CLINIC BUILDING A SOUTH (CBS) LEVEL 3 & 4 WAN/FIBER REVISIONS

10-CBS E1.3 CLINIC BUILDING A SOUTH (CBS) LEVEL 1 POWER PLAN

10-CBS E1.4 CLINIC BUILDING A SOUTH (CBS) LEVEL 2 POWER PLAN

10-CBS E1.5 CLINIC BUILDING A SOUTH (CBS) LEVEL 3 POWER PLAN

10-CBS E1.6 CLINIC BUILDING A SOUTH (CBS) LEVEL 4 POWER PLAN

10-CBS E1.7 CLINIC BUILDING A SOUTH (CBS) BONDING PLANS

11-PSN E1.1 PARKING STAFF NORTH (PSN) LEVEL 1 WAN/FIBER REVISIONS

12-PVN E1.1 PARKING VISITOR NORTH (PVN) LEVEL 1 WAN/FIBER REVISIONS

13-PVS E1.1 PARKING VISITOR SOUTH (PVS) LEVEL 1 WAN/FIBER REVISIONS

14-PTSD E1.1 POST TRAUMATIC STRESS BUILDING LEVEL 1 WAN/FIBER REVISIONS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PROTECTION ENGINEERING

100 CREEK ROAD, SUITE 102

Phase

DRIPPING SPRINGS, TEXAS 78620

(512) 380-1988 Consultant POC

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

FOURFRONT DESIGN, INC

517 7TH STREET

RAPID CITY, SOUTH DAKOTA 57701

(605) 342-9470

POC: RAY DAWES

PHYSICAL SECURITY SPECIALIST:

EHRM INFRASTRUCTURE

UPGRADES AT THE EASTERN

COLORADO VA MEDICAL CENTER

AURORA, COLORADO

VA 554-21-700

Project Director

Revisions: Date: 4F PROJECT NO: 15.2226.30

OCT 18 2021 RD AZ

COVER SHEET

G 0.0

A1-225

MULTIPURPOSE

(GOLDENROD)

A1-223

TELECOM

A1-225A

OFFICE

A1-212

OFFICE

A1-210

OFFICE

A1-ST1

STAIR

A1-220

STAFF LOUNGE

A1-222

STOR

A1-C06

CORRIDOR

T

10-WCHP7

T

PHASING NOTE:

HEAT PUMP 10-WCHP7 WILL BE

REQUIRED TO BE REPLACED AFTER

NORMAL WORKING HOURS DUE TO

LOCATION IN CEILING OF CORRIDOR.

RECOMMENDED

ICRA CONTAINMENT

AREA BOUNDARY

CEILING TILES AND

GRID TO BE REMOVED

AND REINSTALLED

A1-309

MED ROOM

A1-307

OFFICE

A1-308

RECEPTION

A1-315

WAIT

A1-C16

CORRIDOR

A1-351

TELECOM

A1-353

ELEV

MACHINE

ROOM

A1-305

STORAGE

A1-303

CLEAN SUPPLY

A1-C25

CORRIDOR

A1-375

OFFICE

A1-373

OFFICE

A1-371

OFFICE

A1-369

OFFICE

A1-C14

CORRIDOR

10-WCHP4

TT

PHASING NOTE:

HEAT PUMP 10-WCHP4 WILL BE

REQUIRED TO BE REPLACED

AFTER NORMAL WORKING

HOURS DUE TO LOCATION IN

CEILING OF WAITING ROOM.

RECOMMENDED

ICRA CONTAINMENT

AREA BOUNDARY

CEILING TILES AND

GRID TO BE REMOVED

AND REINSTALLED

REMOVE RUBBER

BASE TRIM

THROUGHOUT

EXISTING FLOOR HAS COMBINATION

12" VCT AND LEVELING CONCRETE,

MIXED INSTALLATION, ALL ONE

LEVEL. PREP FLOOR BY CLEANING

AND LEVELING.

UP

A1-233

MULTIPURPOSE

(BLUE VERVAIN)

A1-229A

CHAIR STOR

A1-231

MULTIPURPOSE

(BUTTERFLY WEED)

A1-229

MULTIPURPOSE

(DAISY)

A1-225B

CHAIR STOR

A1-227

CHAIR STOR

A1-225

MULTIPURPOSE

(GOLDENROD)

A1-223

TELECOM

A1-225A

OFFICE

A1-214

OFFICE

A1-216

OFFICE

A1-C03

VESTIBULE

A1-213

OFFICE

A1-215

OFFICE

A1-207

MULTIPURPOSE

(WILD BERGAMOT)

A1-209

HAC

A1-212

OFFICE

A1-210

OFFICE

A1-ST1

STAIR

A1-206

WOMEN'S RESTROOM

A1-202

MEN'S RESTROOM

A1-204

HAC

A1-C01

CORRIDOR

A1-103

OFFICE

A1-105

OFFICE

A1-C02

CORRIDOR

A1-C04

CORRIDOR

AE-V01

ELEV

A1-203

ELEC

AE-V02

ELEV

AE-V03

ELEV

A1-100

ELEV LOBBY

A1-109

OFFICE

A1-117

OFFICE

A1-111

CONFERENCE

(PLAINS COTTONWOOD)

A1-101

WAIT

A1-107

OFFICE

A1-C12

CORRIDOR

A1-113

RECEPTION

A1-115

SECRETARY

A1-112

COPY/PRINT

A1-122

STAFF LOUNGE

A1-119

OFFICE

A1-121

OFFICE

A1-C13

CORRIDOR

A1-313

OFFICE

A1-311

OFFICE

A1-C15

CORRIDOR

A1-310

OFFICE

A1-312

OFFICE

A1-309

MED ROOM

A1-307

OFFICE

A1-123

STORAGE

A1-308

RECEPTION

A1-317

COPY/PRINT

A1-319

OFFICE

A1-321

OFFICE

A1-323

OFFICE

A1-325

OFFICE

A1-327

OFFICE

A1-329

OFFICE

A1-331

OFFICE

A1-333

OFFICE

A1-337

PAT TLT

A1-339

PAT TLT

A1-341

STORAGE

A1-343

OFFICE

A1-345

OFFICE

A1-C17

CORRIDOR

A

C

C O

R R

I D

O R

A1-C19

CORRIDOR

A1-335

OFFICE

A1-350

OFFICE

A1-348

OFFICE

A1-357

EQUIPMENT STORAGE

A1-355

MAIN ELEC RM

A1-346

OFFICE

A1-344

OFFICE

A1-C20

CORRIDOR

A1-342

STORAGE

A

C

C O

R R

I D

O R

A1-340

EXAM

A1-338

EXAM

AE-S01

ELEV

A1-C22

CORRIDOR

A1-C23

CORRIDOR

A1-315

WAIT

A1-C16

CORRIDOR

A1-351

TELECOM

A1-353

ELEV

MACHINE

ROOM

A1-ST2

STAIRA1-305

STORAGE

A1-303

CLEAN SUPPLY

A1-301

STORAGE

A1-124

ELEV MACHINE

ROOM

A1-358

ELEC

A1-360

ELEC

A1-ST3

STAIR

A1-356

LOBBY

A1-SE11

ELEC

A1-392

OFFICE

A1-394

OFFICE

A1-396

OFFICE

A1-398

OFFICE

A1-390

OFFICE

A1-388

OFFICE

A1-386

OFFICE

A1-384

OFFICE

A1-374

OFFICE

A1-372

OFFICE

A1-370

OFFICE

A1-368

OFFICE

A1-366

OFFICE

A1-382

OFFICE

A1-380

OFFICE

A1-378

OFFICE

A1-376

OFFICE

A1-363

WAIT

A1-C24

CORRIDOR

A1-C27

CORRIDOR

A1-C25

CORRIDOR

A1-C26

CORRIDOR

A1-375

OFFICE

A1-373

OFFICE

A1-371

OFFICE

A1-369

OFFICE

A1-367

OFFICE

A1-365

COPY/PRINT

A1-C14

CORRIDOR

A1-102A

RECEPTION

A1-102

MAIN LOBBY

A1-C05

CORRIDOR

A1-235

WAIT

A1-235A

RECEPTION

A1-237

TOILET

A1-239

TOILET

A1-241

COPY/PRINT

A1-243

OFFICE

A1-245

OFFICE

A1-244

OFFICE

A1-242

OFFICE

A1-240

OFFICE

A1-246

MEDIA

A1-C08

CORRIDOR

A1-C07

CORRIDOR

A1-C09

CORRIDOR

A1-C10

CORRIDOR

A1-248

OFFICE

A1-250

OFFICE

A1-252

OFFICE

A1-254

OFFICE

A1-256

OFFICE

A1-258

OFFICE

A1-260

OFFICE

A1-230

MULTIPURPOSE

(YARROW)

A1-232

MULTIPURPOSE

(WHITE ASTER)

A1-C07

CORRIDOR

A1-228

WAIT

A1-220

STAFF LOUNGE

A1-222

STOR

A1-218

MULTIPURPOSE

(CONEFLOWER)

A1-C06

CORRIDOR

GENERAL NOTE:

CONTRACTOR TO PROVIDE

CONTAINMENT AND FILTERED

AIR/PRESSURE CONTROL FOR WORK

AREAS IN BUILDING #10 THAT MEET OR

EXCEED REQUIREMENTS FOR

INFECTIOUS CONTROL RISK LEVEL 3.

BARRIERS TO BE TAKEN DOWN AT END

OF SHIFT FOR AFTER HOURS WORK,

AND CEILING TILE TO BE REPLACED

FOR SMOKE/FIRE SPREAD

CONTAINMENT WHEN CONSTRUCTION

SHIFT IS NOT ACTIVE. AT COR OPTIONS,

BARRIERS MAY BE LEFT UP

TEMPORARILY IN AREAS OF NORMAL

WORKING HOURS, BUT CEILING TILE TO

BE REPLACED WHEN CONSTRUCTION

ACTIVITIES ARE NOT ACTIVE.

IN THE CASE WHERE GRID IS

REMOVED, CONTRACTOR TO ADD

TEMPORARY GRID IN PLACE TO

SUPPORT TILE DURING PERIODS OF

CONSTRUCTION NON-ACTIVITY.

A1-309

MED ROOM

A1-307

OFFICE

A1-308

RECEPTION

A1-338

EXAM

A1-315

WAIT

A1-C16

CORRIDOR

A1-351

TELECOM

A1-353

ELEV

MACHINE

ROOM

A1-ST2

STAIRA1-305

STORAGE

A1-C25

A1-375

OFFICE

A1-373

OFFICE

A1-371

OFFICE

A1-C14

CORRIDOR

10-WCHP4

TT

PHASING NOTE:

HEAT PUMP 10-WCHP4 WILL BE

REQUIRED TO BE REPLACED

AFTER NORMAL WORKING

HOURS DUE TO LOCATION IN

CEILING OF WAITING ROOM.

NEW 12"x12" VCT TILE

COVERING OVER NEW

STATIC DISSIPATING

GRID (REFER TO

ELECTRICAL FOR SDG)

NEW REMOVE

RUBBER BASE

THROUGHOUT

NEW TRANSITION

STRIP AT DOOR

FIRST FLOOR ARCHITECTURAL

DEMOLITION AND PLAN

10-CBS A 1.0

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PROTECTION ENGINEERING

100 CREEK ROAD, SUITE 102

Phase

DRIPPING SPRINGS, TEXAS 78620

(512) 380-1988 Consultant POC

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

FOURFRONT DESIGN, INC

517 7TH STREET

RAPID CITY, SOUTH DAKOTA 57701

(605) 342-9470

POC: RAY DAWES

PHYSICAL SECURITY SPECIALIST:

EHRM INFRASTRUCTURE

UPGRADES AT THE EASTERN

COLORADO VA MEDICAL CENTER

AURORA, COLORADO

VA 554-21-700

Project Director

Revisions: Date: 4F PROJECT NO: 15.2226.30

OCT 18 2021 RD AZ

10.CBS

N

TELECOM A1-223 ARCH DEMOLITION

A 1.0

SCALE: 1/4" = 1'-0"

N

TELECOM A1-351 ARCH DEMOLITION

A 1.0

SCALE: 1/4" = 1'-0"

N

FIRST FLOOR TELECOM LOCATIONS

A 1.0

SCALE: 1/16" = 1'-0"

N

TELECOM A1-351 ARCH PLAN

A 1.0

SCALE: 1/4" = 1'-0"

A2-235

OFFICE

A2-233

STORAGE

A2-231

COPY/PRINT

A2-214

STAFF LOUNGE

A2-213A

OFFICE

A2-211B

OFFICE

A2-219

OFFICE

A2-221

OFFICE

A2-210

STORAGE

A2-212

STORAGE

A2-221A

OFFICE

A2-214A

TELECOM ROOM

A2-ST1

STAIR

A C

C O

R R

I D

O R

A C

C O

R R

I D

O R

A2-209B

OFFICE

A2-209A

OFFICE

A C

C O

R R

I D

O R

A2-207B

OFFICE

A2-239

OFFICE

A2-237

VESTIBULE

T

10-WCHP11

T

PHASING NOTE:

AT DISCRETION OF COR, WORK

IN THIS AREA MAY BE DURING

NORMAL WORKING HOURS AS

LONG AS ICRA BARRIERS AND

CEILING TILES ARE REPLACED

AT THE END OF EACH SHIFT.

RECOMMENDED

ICRA CONTAINMENT

AREA BOUNDARY

CEILING TILES AND

GRID TO BE REMOVED

AND REINSTALLED

A2-308

STAFF LOUNGE

A2-102A

BREAK

A2-102

CONFERENCE

(PRAIRIE SAGE)

A2-308A

TELECOM

A2-305A

OFFICE

A2-307B

OFFICE

A2-307A

OFFICE

C O

R R

I D

O R

A2-309B

OFFICE

A2-310

COPY/PRINT

A2-312

OFFICE

A2-314

OFFICE

A2-309A

OFFICE

C O

R R

I D

O R

A2-311B

OFFICE

A2-311A

OFFICE

C O

R R

I D

O R

A2-C26

CORRIDOR

A2-344B A2-340AA2-348A A2-344A

A2-335

OFFICE

A2-337

OFFICE

A2-339

OFFICE

A2-341

COPY/PRINT

T

10-WCHP9

PHASING NOTE:

AT DISCRETION OF COR, WORK IN

THIS AREA MAY BE DURING

NORMAL WORKING HOURS AS

LONG AS ICRA BARRIERS AND

CEILING TILES ARE REPLACED AT

THE END OF EACH SHIFT.

RECOMMENDED

ICRA CONTAINMENT

AREA BOUNDARY

CEILING TILES AND

GRID TO BE REMOVED

AND REINSTALLED

DN

UP

A2-356

OFFICE

A2-354

OFFICE

A2-352

OFFICE

A2-346

OFFICE

A2-332

OFFICE

A2-330

OFFICE

A2-308

STAFF LOUNGE

A2-321

OFFICE

A2-322

OFFICE

A2-203

SHARED OFFICE

A2-102A

BREAK

A2-324A

OFFICE

A2-319

CONFERENCE

(MOUNTAIN ASH)

A2-102

CONFERENCE

(PRAIRIE SAGE)

A2-200

STORAGE

A2-300

CLOSET

A2-230

CONFERENCE ROOM

(BLAZING STAR)

A2-228

OFFICE

A2-227

OFFICE

A2-225

OFFICE

A2-235

OFFICE

A2-233

STORAGE

A2-226C

OFFICE

A2-226B

OFFICE

A2-231

COPY/PRINT

A2-229

OFFICE

A2-214

STAFF LOUNGE

A2-213A

OFFICE

A2-211B

OFFICE

A2-215

OFFICE

A2-217

OFFICE

A2-219

OFFICE

A2-221

OFFICE

A2-210

STORAGE

A2-212

STORAGE

A2-221A

OFFICE

A2-327

STORAGE/FILING

A2-214A

TELECOM ROOM

A2-247

MEN'S RESTROOM

A2-253

WOMEN'S RESTROOM

A2-251

ELEC

A2-308A

TELECOM

A2-327A

ELEC

A2-223

OFFICE

A2-ST1

STAIR

A2-249

HAC

AE-V01

ELEV

AE-V02

ELEV

A2-ST2

STAIR

AE-S01

ELEV

A2-205

CONFERENCE

A2-232

OFFICE

A2-100

LOBBY

A

C

C O

R R

I D

O R

A

C

C O

R R

I D

O R

A2-C09

CORRIDOR

A2-326A

STORAGE

A2-326

LOBBY

A

C

C O

R R

I D

O R

A2-C02

CORRIDOR

A2-213B

OFFICE

A2-211D

OFFICE

A2-213C

OFFICE

A2-211F

OFFICE

A2-213D

OFFICE

A2-211G

OFFICE

A2-209B

OFFICE

A2-221E

OFFICE

A2-209F

OFFICE

A2-221C

OFFICE

A2-209D

OFFICE

A2-209A

OFFICE

A

C

C O

R R

I D

O R

A2-207B

OFFICE

A2-209E

OFFICE

A2-207F

OFFICE

A2-209C

OFFICE

A2-207D

OFFICE

A2-C11

CORRIDOR

A2-207A

OFFICE

A

C

C O

R R

I D

O R

A2-203B

OFFICE

A2-207E

OFFICE

A2-203E

OFFICE

A2-207C

OFFICE

A2-203D

OFFICE

A2-203A

OFFICE

A

C

C O

R R

I D

O R

A2-201A

OFFICE

A2-203C

OFFICE

A2-201B

OFFICE

A2-301A

OFFICE

A

C

C O

R R

I D

O R

A2-305B

OFFICE

A2-301B

OFFICE

A2-305D

OFFICE

A2-305A

OFFICE

A

C

C O

R R

I D

O R

A2-307B

OFFICE

A2-305E

OFFICE

A2-307F

OFFICE

A2-305C

OFFICE

A2-307D

OFFICE

A2-307A

OFFICE

A

C

C O

R R

I D

O R

A2-309B

OFFICE

A2-307E

OFFICE

A2-309F

OFFICE

A2-307C

OFFICE

A2-309D

OFFICE

AE-V03

ELEV

A2-310

COPY/PRINT

A2-312

OFFICE

A2-314

OFFICE

A2-309A

OFFICE

A

C

C O

R R

I D

O R

A2-311B

OFFICE

A2-309E

OFFICE

A2-311F

OFFICE

A2-309C

OFFICE

A2-311D

OFFICE

A2-311A

OFFICE

A

C

C O

R R

I D

O R

A2-313B

OFFICE

A2-311E

OFFICE

A2-313F

OFFICE

A2-311C

OFFICE

A2-313D

OFFICE

A2-C18

CORRIDOR

A2-C26

CORRIDOR

A2-316

OFFICE

A2-320

OFFICE

A2-313A

OFFICE

A

C

C O

R R

I D

O R

A2-315B

OFFICE

A2-313E

OFFICE

A2-315F

OFFICE

A2-313C

OFFICE

A2-315D

OFFICE

A2-315A

OFFICE

A

C

C O

R R

I D

O R

A2-317A

OFFICE

A2-315E

OFFICE

A2-317C

OFFICE

A2-315C

OFFICE

A2-317B

OFFICE

A2-320

OFFICE

A

C

C O

R R

I D

O R

A2-323

OFFICE

A2-325

OFFICE

A2-324B

OFFICE

A-SE11

ELEV

A2-ST3

STAIR

A2-326B

STORAGE

A2-329B

OFFICE

A

C

C O

R R

I D

O R

A2-329A

OFFICE

A2-328B

OFFICE

A2-328A

OFFICE

A2-329C

OFFICE

A2-328C

OFFICE

A2-329D

OFFICE

A2-328D

OFFICE

A2-329E

OFFICE

A2-328E

OFFICE

A2-329F

OFFICE

A2-328F

OFFICE

A2-334

OFFICE

A2-336

OFFICE

A2-338

OFFICE

A2-342

OFFICE

A2-344F

OFFICE

A2-340C

OFFICE

A2-344B

OFFICE

A2-340A

OFFICE

A2-344D

OFFICE

A2-340B

OFFICE

A

C

C O

R R

I D

O R

A2-348C

OFFICE

A2-344E

OFFICE

A2-348A

OFFICE

A2-344A

OFFICE

A2-348B

OFFICE

A2-344C

OFFICE

A

C

C O

R R

I D

O R

A2-331

ELEVATOR

VESTIBULE

A2-333

VESTIBULE

A2-335

OFFICE

A2-337

OFFICE

A2-339

OFFICE

A2-341

COPY/PRINT

A2-343B

OFFICE

A

C

C O

R R

I D

O R

A2-343A

OFFICE

A2-350B

OFFICE

A2-350A

OFFICE

A2-343C

OFFICE

A2-350C

OFFICE

A2-343D

OFFICE

A2-350D

OFFICE

A2-343E

OFFICE

A2-350E

OFFICE

A2-343F

OFFICE

A2-350F

OFFICE

A

C

C O

R R

I D

O R

A2-358

OFFICE

A2-103

CONFERENCE

(LAVENDER)

A2-104

BADGING ROOM

(GREEN ASH)

A2-105

PIV / BADGING

OFFICE

A2-101

RECEPTION

A2-243

OFFICE

A2-241

OFFICE

A2-239

OFFICE

A2-237

VESTIBULE

A2-242F

OFFICE

A2-246C

OFFICE

A2-242B

OFFICE

A2-246A

OFFICE

A2-242D

OFFICE

A2-246B

OFFICE

A

C

C O

R R

I D

O R

A2-252

OFFICE

A2-250

OFFICE

A2-248

OFFICE

A2-244

OFFICE

A2-238F

OFFICE

A2-242E

OFFICE

A2-238B

OFFICE

A2-242A

OFFICE

A2-238D

OFFICE

A2-242C

OFFICE

A

C

C O

R R

I D

O R

A2-234C

OFFICE

A2-238E

OFFICE

A2-234A

OFFICE

A2-238A

OFFICE

A2-234B

OFFICE

A2-238C

OFFICE

A

C

C O

R R

I D

O R

A

C

C O

R R

I D

O R

A2-C03

CORRIDOR

A2-C08

CORRIDOR

A2-236C

OFFICE

A2-236A

OFFICE

A2-240B

OFFICE

A2-240A

OFFICE

A2-236D

OFFICE

A2-236B

OFFICE

GENERAL NOTE:

CONTRACTOR TO PROVIDE

CONTAINMENT AND FILTERED

AIR/PRESSURE CONTROL FOR WORK

AREAS IN BUILDING #10 THAT MEET OR

EXCEED REQUIREMENTS FOR

INFECTIOUS CONTROL RISK LEVEL 3.

BARRIERS TO BE TAKEN DOWN AT END

OF SHIFT FOR AFTER HOURS WORK,

AND CEILING TILE TO BE REPLACED

FOR SMOKE/FIRE SPREAD

CONTAINMENT WHEN CONSTRUCTION

SHIFT IS NOT ACTIVE. AT COR OPTIONS,

BARRIERS MAY BE LEFT UP

TEMPORARILY IN AREAS OF NORMAL

WORKING HOURS, BUT CEILING TILE TO

BE REPLACED WHEN CONSTRUCTION

ACTIVITIES ARE NOT ACTIVE.

IN THE CASE WHERE GRID IS

REMOVED, CONTRACTOR TO ADD

TEMPORARY GRID IN PLACE TO

SUPPORT TILE DURING PERIODS OF

CONSTRUCTION NON-ACTIVITY.

SECOND FLOOR ARCHITECTURAL

DEMOLITION

10-CBS A 1.1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PROTECTION ENGINEERING

100 CREEK ROAD, SUITE 102

Phase

DRIPPING SPRINGS, TEXAS 78620

(512) 380-1988 Consultant POC

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

FOURFRONT DESIGN, INC

517 7TH STREET

RAPID CITY, SOUTH DAKOTA 57701

(605) 342-9470

POC: RAY DAWES

PHYSICAL SECURITY SPECIALIST:

EHRM INFRASTRUCTURE

UPGRADES AT THE EASTERN

COLORADO VA MEDICAL CENTER

AURORA, COLORADO

VA 554-21-700

Project Director

Revisions: Date: 4F PROJECT NO: 15.2226.30

OCT 18 2021 RD AZ

10.CBS

N

TELECOM A2-214A ARCH DEMOLITION

A 1.1

SCALE: 1/4" = 1'-0"

N

TELECOM A2-308A ARCH DEMOLITION

A 1.1

SCALE: 1/4" = 1'-0"

N

SECOND FLOOR TELECOM LOCATIONS

A 1.1

SCALE: 1/16" = 1'-0"

A3-222

A3-245

OFFICE

A3-244A

OFFICE

A3-246A

OFFICE

A3-242A

OFFICE

A3-244B

OFFICE

A3-238A

OFFICE

A3-242B

OFFICE

A3-238B

OFFICE

A3-C05

CORRIDOR

A3-243

STORAGE

A3-243A

TELECOM

A3-220

OFFICE

A3-219A

STORAGE

STORAGE

A3-C03

CORRIDOR

A3-218

STAFF LOUNGE

A3-216

COPY/PRINT

A3-241

VESTIBULE

A3-239

OFFICE

A3-ST1

STAIR

A3-237A

OFFICE

A3-237B

OFFICE

T

W

C H

P

T

PHASING NOTE:

AT DISCRETION OF COR,

WORK IN THIS AREA MAY BE

DURING NORMAL WORKING

HOURS AS LONG AS ICRA

BARRIERS AND CEILING

TILES ARE REPLACED AT

THE END OF EACH SHIFT.

RECOMMENDED

ICRA CONTAINMENT

AREA BOUNDARY

CEILING TILES AND

GRID TO BE REMOVED

AND REINSTALLED

A3-306

COMPUTER

CLASSROOM

(CHOKECHERRY)

STORAGE STORAGE

A3-308

STAFF LOUNGE

A3-310

OFFICE

A3-312

OFFICE

A3-335

TELECOM

A3-328B

OFFICE

A3-328A

OFFICE

A3-332

(PINON PINE)

A3-327B

OFFICE

A3-327D

OFFICE

A3-325A

OFFICE

A3-325C

OFFICE

A3-333A

OFFICE

A3-333B

OFFICE

A3-327A

OFFICE

A3-327C

OFFICE

A3-C08

CORRIDOR

A3-337

STAFF LOUNGE

A3-341

COPY/PRINT

A3-336A

OFFICE

A3-336B

A C

C O

R R

I D

O R

A3-338A

OFFICE

A3-338B

A3-338B

OFFICE

A3-338D

A3-344A

OFFICE

A3-344B

A C

C O

R R

I D

O R

A3-ST2

STAIR

T

W

C H

P

T

PHASING NOTE:

HEAT PUMP 10-WCHP13 WILL

BE REQUIRED TO BE REPLACED

AFTER NORMAL WORKING

HOURS DUE TO LOCATION IN

CEILING OF CORRIDOR.

RECOMMENDED

ICRA CONTAINMENT

AREA BOUNDARY

CEILING TILES AND

GRID TO BE REMOVED

AND REINSTALLED

DN

UP

A3-254

OFFICE

A3-252

OFFICE

A3-250

OFFICE

A3-253

OFFICE

A3-249

OFFICE

A3-247B

OFFICE

A3-247A

OFFICE

A3-248B

OFFICE

A3-248A

OFFICE

A3-C09

CORRIDOR

A

C

C O

R R

I D

O R

A3-223C

OFFICE

A3-223A

OFFICE

A3-223B

OFFICE

A3-222

OFFICE

A3-221

OFFICE

A3-245

OFFICE

A3-244M

OFFICE

A3-244A

OFFICE

A3-244G

OFFICE

A3-244I

OFFICE

A3-244K

OFFICE

A3-244E

OFFICE

A3-244C

OFFICE

A3-246G

OFFICE

A3-246A

OFFICE

A3-246D

OFFICE

A3-246E

OFFICE

A3-246F

OFFICE

A3-246C

OFFICE

A3-246B

OFFICE

A

C

C O

R R

I D

O R

A3-242M

OFFICE

A3-242A

OFFICE

A3-242G

OFFICE

A3-242I

OFFICE

A3-242K

OFFICE

A3-242E

OFFICE

A3-242C

OFFICE

A3-244N

OFFICE

A3-244B

OFFICE

A3-244H

OFFICE

A3-244J

OFFICE

A3-244L

OFFICE

A3-244F

OFFICE

A3-244D

OFFICE

A

C

C O

R R

I D

O R

A3-238M

OFFICE

A3-238A

OFFICE

A3-238G

OFFICE

A3-238I

OFFICE

A3-238K

OFFICE

A3-238E

OFFICE

A3-238C

OFFICE

A3-242N

OFFICE

A3-242B

OFFICE

A3-242H

OFFICE

A3-242J

OFFICE

A3-242L

OFFICE

A3-242F

OFFICE

A3-242D

OFFICE

A

C

C O

R R

I D

O R

A3-236A

OFFICE

A3-236G

OFFICE

A3-236I

OFFICE

A3-236J

SHARED OFFICE

A3-236E

OFFICE

A3-236C

OFFICE

A3-238N

OFFICE

A3-238B

OFFICE

A3-238H

OFFICE

A3-238J

OFFICE

A3-238L

OFFICE

A3-238F

OFFICE

A3-238D

OFFICE

A

C

C O

R R

I D

O R

A3-230A

OFFICE

A3-230D

OFFICE

A3-228

OFFICE

A3-230C

OFFICE

A3-230B

OFFICE

A3-236M

OFFICE

A3-236B

OFFICE

A3-236H

OFFICE

A3-238K

OFFICE

A3-236F

OFFICE

A3-236D

OFFICE

A3-C05

CORRIDOR

A3-243

STORAGE

A3-243A

TELECOM

A3-220

OFFICE

A3-219A

STORAGE

A3-219B

STORAGE

A3-C03

CORRIDOR

A3-219

CONFERENCE

(BOXELDER)

A3-218

STAFF LOUNGE

A3-216

COPY/PRINT

A3-241

VESTIBULE

A3-239

OFFICE

A3-ST1

STAIR

A3-237A

OFFICE

A3-237B

OFFICE

A3-235

STORAGE

A3-229

WOMEN'S RESTROOM

A3-233

MEN'S RESTROOM

A3-231

HAC

A3-211

CONFERENCE

(DOUGLAS FIR)

A3-217B

OFFICE

A3-215F

OFFICE

A3-217A

OFFICE

A3-215E

OFFICE

A

C

C O

R R

I D

O R

A3-213B

OFFICE

A3-213D

OFFICE

A3-213E

OFFICE

A3-213F

OFFICE

A3-215A

OFFICE

A3-215B

OFFICE

A3-215C

OFFICE

A3-213A

OFFICE

A3-213C

OFFICE

A

C

C O

R R

I D

O R

A3-C18

CORRIDOR

A3-209

OFFICE

A3-C02

CORRIDOR

A3-207B

OFFICE

A3-207D

OFFICE

A3-207A

OFFICE

A3-207C

OFFICE

A3-C19

CORRIDOR

A3-205

SIMULATION LAB

A3-201

STAFF LOUNGE

A3-301

COPY/PRINT

A3-202

STORAGE

A3-227

ELEC

AE-V01

ELEV

AE-V02

ELEV

AE-V03

ELEV

A3-100

ELEV LOBBY

A3-C20

CORRIDOR

A3-302

STORAGE

A3-225

ALCOVE

A3-103

HAC

A

C

C O

R R

I D

O R

A3-306

COMPUTER

CLASSROOM

(CHOKECHERRY)

A3-304A

STORAGE

A3-306A

STORAGE

A3-303A

OFFICE

A3-303B

OFFICE

A3-303C

OFFICE

A

C

C O

R R

I D

O R

A3-305B

OFFICE

A3-305D

OFFICE

A3-305F

OFFICE

A3-305A

OFFICE

A3-305C

OFFICE

A3-305E

OFFICE

A

C

C O

R R

I D

O R

A3-307B

OFFICE

A3-307D

OFFICE

A3-307F

OFFICE

A3-307A

OFFICE

A3-307C

OFFICE

A3-307E

OFFICE

A

C

C O

R R

I D

O R

A3-311B

OFFICE

A3-311D

OFFICE

A3-311F

OFFICE

A3-C06

CORRIDOR

A3-308

STAFF LOUNGE

A3-310

OFFICE

A3-312

OFFICE

A3-335

TELECOM

A3-C01

CORRIDOR

A3-224

CONFERENCE

(GAMBREL OAK)

A3-226

CONSULT

A3-324

OFFICE

A

C

C O

R R

I D

O R

A3-326E

OFFICE

A3-326B

OFFICE

A3-326C

OFFICE

A3-326D

OFFICE

A3-326A

OFFICE

A3-328E

OFFICE

A3-328B

OFFICE

A3-328C

OFFICE

A3-328D

OFFICE

A3-328A

OFFICE

A3-C34

CORRIDOR

A3-C33

CORRIDOR

A3-330

MULTIPURPOSE

(SANDBAR WILLOW)

A3-332

MULTIPURPOSE

(PINON PINE)

A3-334

OFFICE

A3-340

OFFICE

A3-342

OFFICE

A3-325B

OFFICE

A3-325D

OFFICE

A3-327B

OFFICE

A3-327D

OFFICE

A3-325A

OFFICE

A3-325C

OFFICE

A3-333A

OFFICE

A3-333B

OFFICE

A3-327A

OFFICE

A3-327C

OFFICE

A3-C08

CORRIDOR

A3-337

STAFF LOUNGE

A3-341

COPY/PRINT

A3-336C

OFFICE

A3-336A

OFFICE

A3-336B

OFFICE

A

C

C O

R R

I D

O R

A3-338A

OFFICE

A3-338B

OFFICE

A3-338B

OFFICE

A3-338D

OFFICE

A3-344A

OFFICE

A3-344B

OFFICE

A3-344C

OFFICE

A3-344D

OFFICE

A3-344E

OFFICE

A

C

C O

R R

I D

O R

A3-346A

OFFICE

A3-346C

OFFICE

A3-346E

OFFICE

A3-346G

OFFICE

A3-346I

OFFICE

A

C

C O

R R

I D

O R

A

C

C O

R R

I D

O R

A3-346B

OFFICE

A3-346D

OFFICE

A3-348A

OFFICE

A3-348C

OFFICE

A3-346F

OFFICE

A3-348E

OFFICE

A3-346H

OFFICE

A3-348G

OFFICE

A3-346J

OFFICE

A3-348H

OFFICE

A3-348B

OFFICE

A3-348D

OFFICE

A3-348F

OFFICE

A

C

C O

R R

I D

O R

A3-343

VEST

A3-345

ELEV VEST

A3-347

OFFICE

AE-S01

ELEV

A3-ST2

STAIR

A3-347A

ELEC

A3-314

OFFICE

A3-316

COPY/PRINT

A3-311A

OFFICE

A3-311C

OFFICE

A3-311E

OFFICE

A

C

C O

R R

I D

O R

A3-313B

OFFICE

A3-313D

OFFICE

A3-313F

OFFICE

A3-313A

OFFICE

A3-313C

OFFICE

A3-313E

OFFICE

A

C

C O

R R

I D

O R

A3-315B

OFFICE

A3-315D

OFFICE

A3-315F

OFFICE

A3-315A

OFFICE

A3-315C

OFFICE

A3-315E

OFFICE

A

C

C O

R R

I D

O R

A3-317A

OFFICE

A3-317B

OFFICE

A3-317C

OFFICE

A3-317E

OFFICE

A3-317G

OFFICE

A3-319B

OFFICE

A3-317D

OFFICE

A3-319D

OFFICE

A3-317F

OFFICE

A

C

C O

R R

I D

O R

A3-323

OFFICE

A3-321

OFFICE

A3-319A

OFFICE

A3-319C

OFFICE

A3-320C

OFFICE

A3-320B

OFFICE

A3-320A

OFFICE

A3-322B

OFFICE

A3-C07

CORRIDOR

A3-349B

OFFICE

A3-349A

OFFICE

A3-322A

OFFICE

A3-322C

OFFICE

A3-353

STORAGE

A-SE11

ELEV

A3-351

LOBBY

A3-352

STORAGE

A3-350

OFFICE

A3-ST3

STAIR

GENERAL NOTE:

CONTRACTOR TO PROVIDE

CONTAINMENT AND FILTERED

AIR/PRESSURE CONTROL FOR WORK

AREAS IN BUILDING #10 THAT MEET OR

EXCEED REQUIREMENTS FOR

INFECTIOUS CONTROL RISK LEVEL 3.

BARRIERS TO BE TAKEN DOWN AT END

OF SHIFT FOR AFTER HOURS WORK,

AND CEILING TILE TO BE REPLACED

FOR SMOKE/FIRE SPREAD

CONTAINMENT WHEN CONSTRUCTION

SHIFT IS NOT ACTIVE. AT COR OPTIONS,

BARRIERS MAY BE LEFT UP

TEMPORARILY IN AREAS OF NORMAL

WORKING HOURS, BUT CEILING TILE TO

BE REPLACED WHEN CONSTRUCTION

ACTIVITIES ARE NOT ACTIVE.

IN THE CASE WHERE GRID IS

REMOVED, CONTRACTOR TO ADD

TEMPORARY GRID IN PLACE TO

SUPPORT TILE DURING PERIODS OF

CONSTRUCTION NON-ACTIVITY.

THIRD FLOOR ARCHITECTURAL

DEMOLITION

10-CBS A 1.2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PROTECTION ENGINEERING

100 CREEK ROAD, SUITE 102

Phase

DRIPPING SPRINGS, TEXAS 78620

(512) 380-1988 Consultant POC

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

FOURFRONT DESIGN, INC

517 7TH STREET

RAPID CITY, SOUTH DAKOTA 57701

(605) 342-9470

POC: RAY DAWES

PHYSICAL SECURITY SPECIALIST:

EHRM INFRASTRUCTURE

UPGRADES AT THE EASTERN

COLORADO VA MEDICAL CENTER

AURORA, COLORADO

VA 554-21-700

Project Director

Revisions: Date: 4F PROJECT NO: 15.2226.30

OCT 18 2021 RD AZ

10.CBS

N

TELECOM A3-243A ARCH DEMOLITION

A 1.2

SCALE: 1/4" = 1'-0"

N

TELECOM A3-335 ARCH DEMOLITION

A 1.2

SCALE: 1/4" = 1'-0"

N

THIRD FLOOR TELECOM LOCATIONS

A 1.2

A4-C03

CORRIDOR

A4-C06

CORRIDOR

A4-C05

CORRIDOR

A4-220

OFFICE

A4-243

STAFF TLT

A4-241

STAFF TLT

A4-239

OFFICE

A4-237

VEST

A4-217

MULTIPURPOSE

(SUNFLOWER)

A4-219

MULTIPURPOSE

(SUNFLOWER)

A4-C03

CORRIDOR

A4-218

WAITING

A4-216

TELECOM

A4-214

COPY/PRINT

A4-ST1

STAIR

A4-206

STORAGE

A4-235

MULTIPURPOSE

(MILK WEED)

A4-213

STAFF LOUNGE

T

10-WCHP19

T

PHASING NOTE:

AT DISCRETION OF COR, WORK IN

THIS AREA MAY BE DURING

NORMAL WORKING HOURS AS

LONG AS ICRA BARRIERS AND

CEILING TILES ARE REPLACED AT

THE END OF EACH SHIFT.

RECOMMENDED

ICRA CONTAINMENT

AREA BOUNDARY

CEILING TILES AND

GRID TO BE REMOVED

AND REINSTALLED

A4-334

HAC

A4-336

OFFICE

A4-338A

OFFICE

A4-338

WAITING

A4-C13

CORRIDOR

OFFICE OFFICE OFFICE OFFICE OFFICE

A4-341

OFFICE

A4-343

TELECOM

A

C

C O

R R

I D

O R

A4-340

OFFICE

A4-351

MED ROOM

A4-349

PATIENT TLT

A4-345A

ISOLATION

TLT

A4-345

EXAM

A4-353

OFFICE

A4-355

OFFICE

A4-357

OFFICE

A4-359

STORAGE

A4-C17

CORRIDOR

A4-306

MULTIPURPOSE

(BLANKET FLOWER)

T1 W

C H

P

T

PHASING NOTE:

HEAT PUMP 10-WCHP17 WILL BE

REQUIRED TO BE REPLACED

AFTER NORMAL WORKING

HOURS DUE TO LOCATION IN

CEILING OF CORRIDOR.

RECOMMENDED

ICRA CONTAINMENT

AREA BOUNDARY

CEILING TILES AND

GRID TO BE REMOVED

AND REINSTALLED

DN

UP

DN

A4-253

OFFICE

A4-278

OFFICE

A4-276

OFFICE

A4-253A

STAFF TLT

A4-274

OFFICE

A4-272

OFFICE

A4-270

OFFICE

A4-268

OFFICE

A4-266

OFFICE

A4-264

OFFICE

A4-262

OFFICE

A4-260

OFFICE

A4-258

OFFICE

A4-256

CONFERENCE ROOM

(LUPINE)

A4-C08

CORRIDOR

A4-C09

CORRIDOR

A4-250

WAITING

A4-273

OFFICE

A4-251

OFFICE

A4-249

OFFICE

A4-247

OFFICE

A4-C03

CORRIDOR

A4-245

OFFICE

A

C

C O

R R

I D

O R

A4-269

OFFICE

A4-267

OFFICE

A4-240

OFFICE

A4-265

OFFICE

A4-238

OFFICE

A4-263

OFFICE

A4-236

OFFICE

A4-261

OFFICE

A4-234

OFFICE

A4-259

OFFICE

A4-232

OFFICE

A4-257

OFFICE

A4-230

OFFICE

A4-255

OFFICE

A4-228

OFFICE

A4-105

KIOSK

A

C

C O

R R

I D

O R

A4-C06

CORRIDOR

A4-C05

CORRIDOR

A4-220

OFFICE

A4-243

STAFF TLT

A4-241

STAFF TLT

A4-239

OFFICE

A4-237

VEST

A4-217

MULTIPURPOSE

(SUNFLOWER)

A4-219

MULTIPURPOSE

(SUNFLOWER)

A4-C03

CORRIDOR

A4-218

WAITING

A4-216

TELECOM

A4-214

COPY/PRINT

A4-ST1

STAIR

A4-206

STORAGE

A4-235

MULTIPURPOSE

(MILK WEED)

A4-231

OFFICE

A4-227

MEN'S RESTROOM

A4-223

WOMEN'S RESTROOM

A4-225

HAC

AE-V01

ELEV

AE-V02

ELEV

AE-V03

ELEV

A4-100

VEST

A4-221

ELEC

A4-101

WAITING

A4-C01

CORRIDOR

A4-106

RECEPTION

A4-104

LOBBY

A4-213

STAFF LOUNGE

A4-211

TERRACE

A4-C02

CORRIDOR

A4-207

OFFICE

A4-209

OFFICE

A4-203

OFFICE

A4-201A

TELECOM

A4-205

OFFICE

A4-201

OFFICE

A4-102

OFFICE

A4-103

OFFICE

A

C

C O

R R

I D

O R

A4-334

HAC

A4-336

OFFICE

A4-338A

OFFICE

A4-338

WAITING

A4-C13

CORRIDOR

A4-337

OFFICE

A4-301

WAITING

A4-303

RECEPT

A4-C10

CORRIDOR

A4-339

OFFICE

A4-303A

COPY/PRINT

A4-305

OFFICE

A4-C11

CORRIDOR

A4-302

OFFICE

A4-304

OFFICE

A4-307

OFFICE

A4-309

OFFICE

A4-308

OFFICE

A4-310

OFFICE

A4-341

OFFICE

A4-343

TELECOM

A

C

C O

R R

I D

O R

A4-340

OFFICE

A4-351

MED ROOM

A4-349

PATIENT TLT

A4-345A

ISOLATION

TLT

A4-345

EXAM

A4-353

OFFICE

A4-355

OFFICE

A4-357

OFFICE

A4-359

STORAGE

A4-C17

CORRIDOR

A4-346

OFFICE

A4-348

OFFICE

A4-350

OFFICE

A4-352

OFFICE

A4-354

OFFICE

A

C

C O

R R

I D

O R

A4-356

EXAM

A4-358

EXAM

A4-360

OFFICE

A4-362

OFFICE

A4-364

OFFICE

A4-366

COPY/PRINT

A4-ST2

STAIR

A4-370A

OFFICE

A4-370B

OFFICE

A4-C18

CORRIDOR

A4-C19

CORRIDOR

A4-372

OFFICE

A4-374

OFFICE

A4-376

OFFICE

A4-378

OFFICE

A4-380

OFFICE

A4-382

OFFICE

A4-384

OFFICE

A4-385

OFFICE

A4-386

OFFICE

A4-388

OFFICE

A

C

C O

R R

I D

O R

A4-390

OFFICE

A4-C20

CORRIDOR

A4-391

OFFICE

A4-ST3

STAIR

A4-392

LOBBY

A-SE11

ELEV

A4-393

STORAGE

A4-332

OFFICE

A4-330

OFFICE

AE-S01

ELEV

A4-331

W.C. ALCOVE

A4-365

OFFICE

A4-329

ELEC

A

C

C O

R R

I D

O R

A4-328

SOILED UTIL

A4-326

STAFF LOUNGE

A4-306

MULTIPURPOSE

(BLANKET FLOWER)

A4-312

MULTIPURPOSE

(LOBELLA)

A4-327

STAFF TLT

A4-321

STAFF TLT

A4-322

OFFICE

A4-324

OFFICE

A4-319B

OFFICE

A4-C16

CORRIDOR

A4-315

OFFICE

A4-317

OFFICE

A4-319

VESTIBULE

A4-313

OFFICE

A4-311

OFFICE

GENERAL NOTE:

CONTRACTOR TO PROVIDE

CONTAINMENT AND FILTERED

AIR/PRESSURE CONTROL FOR WORK

AREAS IN BUILDING #10 THAT MEET OR

EXCEED REQUIREMENTS FOR

INFECTIOUS CONTROL RISK LEVEL 3.

BARRIERS TO BE TAKEN DOWN AT END

OF SHIFT FOR AFTER HOURS WORK,

AND CEILING TILE TO BE REPLACED

FOR SMOKE/FIRE SPREAD

CONTAINMENT WHEN CONSTRUCTION

SHIFT IS NOT ACTIVE. AT COR OPTIONS,

BARRIERS MAY BE LEFT UP

TEMPORARILY IN AREAS OF NORMAL

WORKING HOURS, BUT CEILING TILE TO

BE REPLACED WHEN CONSTRUCTION

ACTIVITIES ARE NOT ACTIVE.

IN THE CASE WHERE GRID IS

REMOVED, CONTRACTOR TO ADD

TEMPORARY GRID IN PLACE TO

SUPPORT TILE DURING PERIODS OF

CONSTRUCTION NON-ACTIVITY.

FOURTH FLOOR ARCHITECTURAL

DEMOLITION

10-CBS A 1.3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PROTECTION ENGINEERING

100 CREEK ROAD, SUITE 102

Phase

DRIPPING SPRINGS, TEXAS 78620

(512) 380-1988 Consultant POC

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

FOURFRONT DESIGN, INC

517 7TH STREET

RAPID CITY, SOUTH DAKOTA 57701

(605) 342-9470

POC: RAY DAWES

PHYSICAL SECURITY SPECIALIST:

EHRM INFRASTRUCTURE

UPGRADES AT THE EASTERN

COLORADO VA MEDICAL CENTER

AURORA, COLORADO

VA 554-21-700

Project Director

Revisions: Date: 4F PROJECT NO: 15.2226.30

OCT 18 2021 RD AZ

10.CBS

N

TELECOM A4-216 ARCH DEMOLITION

A 1.3

SCALE: 1/4" = 1'-0"

N

TELECOM A4-343 ARCH DEMOLITION

A 1.3

SCALE: 1/4" = 1'-0"

N

FOURTH FLOOR TELECOM LOCATIONS

A 1.3

SHEET TITLESHEET #

M 0.0 MECHANICAL COVER SHEET

CONTROL VALVE

T

ROOM OR ZONE THERMOSTAT

DUCT THERMOSTAT

EXPANSION VALVE

MOTORIZED DAMPER ACTUATOR

DAMPER, OPPOSED BLADE

CENTRIFUGAL FAN

HUMIDISTAT, ROOM

HUMIDISTAT, DUCT

M MOTOR

PRESSURE SWITCH

, 2-WAY

CONTROL VALVE, 3-WAY

POINT OF DISCONNECT SYMBOL

SMOKE DETECTOR, DUCT

DIFFERENTIAL PRESSURE CONTROLLER

HVAC & CONTROL SYMBOLS

SYMBOL

GLOBE VALVE

GAS COCK

SOLENOID VALVE

PRV

PRESSURE REDUCING VALVE

UNION, THREADED OR FLANGED

WATER HAMMER ARRESTOR

THERMOMETER WITH WELL

FLOOR CLEANOUT, INT. OR EXT.

FLOOR SINK

90 DEGREE ELBOW (UP, DOWN, PLAN)

CHECK VALVE

TEE FITTING (UP, DOWN, PLAN)

PLUG VALVE

PRESSURE GAGE WITH SHUTOFF

PRESSURE SWITCH

PUMP

PRESS./TEMP. RELIEF VALVE

DESCRIPTION

LONG RADIUS SAN. SEWER FITTING

DIRECTION OF FLOW

PLUMBING/PIPING SYMBOLS

COMBINATION WYE & 1/8 BEND

PT/PS

TT

FS

FLOOR DRAIN

RPP BACKFLOW PREVENTOR

DOUBLE CHECK BACKFLOW PREV.

PRESSURE REDUCING VALVE

WATER METER

STRAINER, CAST IRON OR BRONZE

STRAINER WITH BLOW DOWN & PLUG

NG OR LP EQUIPMENT REGULATOR

GATE, BALL, OR FUEL SOV VALVE

FLEXIBLE PIPE CONNECTOR

WH

HOSE BIBB, INTERIOR OR EXTERIOR

CO

WALL CLEANOUT

WYE (PLAN VIEW)

WYE (VERTICAL) WITH 1/4 BEND

1/4 TURN BOILER DRAIN W/CAP

FLOW SWITCH

TEMPERATURE TRANSMITTER (SENSOR)

PRESSURE TRANSMITTER OR SWITCH

AUTO AIR VENT, EXTEND TO DRAIN

ABV

AUTOMATIC BALANCING VALVE

S

MBV

MANUAL BALANCING VALVE

RECTANGULAR DUCT (REFER TO SYS)

LINED RECTANGULAR DUCT

ROUND DUCT-REFER TO SYSTEM SERVED

ROUND LINED OR DOUBLE WALL DUCT

SECTION THROUGH RETURN OR EXHAUST AIR

SECTION THROUGH SUPPLY OR OUTSIDE AIR DUCT

SUPPLY, RETURN, EXHAUST, OR OUTSIDE AIR DUCT

ACCESS DOOR (BOTTOM OR SIDE)

ACOUSTICALLY LINED DUCT

DAMPER, FIRE

DAMPER, MANUAL VOLUME

INCLINED DROP IN DIRECTION OF ARROW

INCLINED RISE IN DIRECTION OF ARROW

TRANSITION, RECTANGULAR TO ROUND

FLEXIBLE DUCT

TRANSITION OR OFFSETTING TRANSITION

TRANSITION, RECTANGULAR

HIGH EFFICIENCY TAKEOFF WITH DAMPER

CEILING SUPPLY AIR DIFFUSER

SIDEWALL SUPPLY AIR REGISTER

ELBOW TURNED DOWN

ELBOW TURNED UP

ELBOW, RADIUS TYPE

ELBOW, SQUARE OR RECTANGULAR TYPE

WITH 22 GA SINGLE TURNING VANES

RETURN OR EXHAUST AIR DUCT

CEILING RETURN AIR REGISTER

OPEN END DUCT

FLEXIBLE CONNECTION

SIDEWALL RETURN AIR REGISTER

FD

BD

R D

DUCTWORK SYMBOLS KEY

OR

AD

12"x10"

8"Ø

12"x10"

8"Ø

BASIC MECHANICAL REQUIREMENTS

FURNISH ALL LABOR AND MATERIALS AND PERFORM ALL

OPERATIONS NECESSARY FOR THE INSTALLATION OF COMPLETE

AND OPERATING MECHANICAL SYSTEMS SUBJECT TO THE

CONDITIONS OF THE CONTRACT. PROVIDE SATISFACTORY

OPERATION OF ALL EQUIPMENT AND CONTROLS TO THE

ARCHITECT/ENGINEER UPON REQUEST.

ALL MATERIALS SHALL BE NEW. SUBSTITUTIONS SHALL BE

APPROVED BY OWNER AND/OR ENGINEER.

VISIT THE PREMISES BEFORE SUBMITTING BID AS NO CHANGE

ORDERS WILL BE ALLOWED FOR LACK OF KNOWLEDGE OF EXISTING

CONDITIONS.

COORDINATE AND ORDER THE PROGRESS OF WORK TO CONFORM

TO THE PROJECT SCHEDULE AND THE PROGRESS OF THE WORK OF

THE OTHER TRADES.

MECHANICAL DRAWINGS ARE DIAGRAMMATIC AND BECAUSE OF THE

SMALL SCALE, IT IS NOT POSSIBLE TO INDICATE EVERY REQUIRED

OFFSET, FITTING, ETC. VERIFY ALL SPACE REQUIREMENTS,

COORDINATING WITH OTHER TRADES, AND INSTALL THE SYSTEMS

IN THE SPACE PROVIDED WITHOUT EXTRA CHARGES TO THE

OWNER.

PERFORM WORK IN ACCORDANCE WITH GOOD COMMERCIAL

PRACTICE. THE GOOD APPEARANCE OF THE FINISHED WORK SHALL

BE OF EQUAL IMPORTANCE WITH ITS MECHANICAL EFFICIENCY AND

INTENT. THE OWNER MAY REJECT WORK IF WORKMANSHIP AND

APPEARANCE ARE NOT SATISFACTORY.

INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH THE

MANUFACTURERS' RECOMMENDATIONS UNLESS SPECIFICALLY

INDICATED OTHERWISE, OR WHERE LOCAL CODES OR

REGULATIONS TAKE PRECEDENCE.

COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS AND

ORDINANCES. COMPLY WITH REQUIREMENTS OF THE UTILITY

COMPANIES. IN THE CASE OF DIFFERENCES BETWEEN THESE

REQUIREMENTS AND ORDINANCES, THE MOST STRINGENT SHALL

GOVERN. CALL FOR INSPECTIONS REQUIRED BY LOCAL BUILDING

INSPECTION AUTHORITY.

PLANS AND SPECIFICATIONS GO HAND IN HAND. WHAT IS REQUIRED

IN ONE IS REQUIRED IN BOTH. WHERE CONFLICTS BETWEEN

SPECIFICATIONS AND PLANS EXIST, THE MOST STRINGENT

REQUIREMENTS SHALL APPLY.

MECHANICAL PLANS SUPERCEDE ARCHITECTURAL PLANS.

BACKGROUND FLOOR PLANS USED FOR MECHANICAL DRAWINGS

MAY SHOW DIFFERENT THAN THE FINAL ARCHITECTURAL LAYOUT.

REFER TO ARCHITECTURAL DRAWINGS FOR ACTUAL DIMENSIONS

AND LAYOUT PLACEMENTS FOR SPACE CONDITIONS.

MECHANICAL DETAILS MAY OR MAY NOT BE DIRECTLY

REFERENCED. ALL DETAILS SHOWN ARE TO BE USED FOR BASIS OF

INSTALLATION IN ALL CASES, IN COORDINATED EFFORT WITH

MANUFACTURERS INSTALLATION RECOMMENDATIONS.

MECHANICAL SHEETS ARE NOT INTENDED TO SPECIFICALLY BE

TRADE SPECIFIC TO MECHANICAL INSTALLATION WORK. ALL

MECHANICAL AND ELECTRICAL TRADES ARE RESPONSIBLE FOR

FAMILIARIZING THEMSELVES AND INCLUDING A COMPLETE

PACKAGE WITHIN THEIR OFFER FOR A COMPLETE SYSTEM.

AT COMPLETION OF WORK, DELIVER COMPLETED PROJECT RECORD

DOCUMENTS MARKED WITH FIELD CHANGES TO OWNER.

PROVIDE A WRITTEN WARRANTY TO THE OWNER COVERING THE

ENTIRE MECHANICAL WORK TO BE FREE FROM DEFECTIVE

MATERIALS, EQUIPMENT AND WORKMANSHIP FOR A PERIOD OF 1

YEAR AFTER DATE OF ACCEPTANCE.

CLEAN EXPOSED SURFACES OF FURNACES, HOT WATER HEATERS,

PLUMBING FIXTURES AND OTHER EXPOSED ITEMS OF GREASE, DIRT

OR OTHER FOREIGN MATERIAL. REMOVE RUBBISH AND DEBRIS

RESULTING FROM THE OPERATIONS AND LEAVE EQUIPMENT

SPACES CLEAN AND READY FOR USE.

MAINTAIN ALL CEILING, FLOOR AND WALL FIRE AND SMOKE

PROTECTION RATINGS. SEAL ALL CONDUIT AND ENCLOSURE

PENETRATIONS TO COMPLY WITH UL ASSEMBLY AND BUILDING

CODE REQUIREMENTS. ALL SEALANTS AND CONSTRUCTIONS SHALL

BE APPROVED BY OWNER PRIOR TO APPLICATION. ALL OPENINGS

SHALL BE SEALED DAILY.

CONTRACT DRAWINGS FOR MECHANICAL WORK ARE IN PART

DIAGRAMMATIC, INTENDED TO CONVEY THE SCOPE OF WORK AND

INDICATE GENERAL ARRANGEMENT OF EQUIPMENT, CONDUITS, AND

APPROXIMATE SIZES AND LOCATIONS OF EQUIPMENT AND

OUTLETS. MECHANICAL/ELECTRICAL TRADES SHALL FOLLOW THESE

DRAWINGS IN LAYING OUT THEIR WORK, CONSULT GENERAL

CONSTRUCTION DRAWINGS TO FAMILIARIZE THEMSELVES WITH ALL

CONDITIONS AFFECTING THEIR WORK, AND SHALL VERIFY SPACES

IN WHICH THEIR WORK WILL BE INSTALLED. COORDINATE WORK

WITH OTHER TRADES AND AS PROJECT CONDITIONS REASONABLY

REQUIRE WITHOUT EXTRA COSTS TO OWNER.

HVAC SPECIFIC:

ALL DUCTWORK DIMENSIONS, AS SHOWN ON THE DRAWINGS, ARE

INTERNAL CLEAR DIMENSIONS AND DUCT SIZE SHALL BE

INCREASED TO COMPENSATE FOR DUCT LINING THICKNESS.

PROVIDE ALL 90 DEGREE SQUARE ELBOWS WITH SINGLE RADIUS

TURNING VANES UNLESS OTHERWISE INDICATED.

COORDINATE DIFFUSER, REGISTER, AND GRILLE LOCATIONS WITH

ARCHITECTURAL REFLECTED CEILING PLANS, LIGHTING, AND

OTHER CEILING ITEMS AND MAKE DUCT MODIFICATIONS TO SUIT.

AT CONTRATORS OPTION, FLEXIBLE DUCT MAY BE USED TO

CONNECT SUPPLY REGISTERS AND DIFFUSERS ON THIS PROJECT

ONLY. RUNS OF FLEXIBLE DUCT SHALL NOT EXCEED 5 FEET, UNLESS

SPECIFICALLY SHOWN ON DRAWING.

ALL DUCTWORK SHALL BE COORDINATED WITH ALL TRADES

INVOLVED. OFFSETS IN DUCTS, INCLUDING DIVIDED DUCTS AND

TRANSITIONS AROUND OBSTRUCTIONS, SHALL BE PROVIDED AT NO

ADDITIONAL COST TO THE OWNER.

MECHANICAL SYSTEMS SHALL COMPLY WITH INTERNATIONAL

MECHANICAL CODE VER 2018 AND INTERNATIONAL ENERGY CODE

VER 2012.

PLUMBING/PIPING SPECIFIC:

PLUMBING/PIPING SYSTEMS SHALL COMPLY WITH INTERNATIONAL

FUEL GAS CODE VER 2018 AND UNIFORM PLUMBING CODE VER 2018.

UTILITIES:

LOCATION OF UNDERGROUND UTILITIES ARE APPROXIMATE. IT IS

THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE EXACT

LOCATIONS IN THE FIELD (NOT ALL UTILITIES ARE SHOWN).

REGULATORY AND CODE REQUIREMENTS:

APPLY FOR AND PAY FOR ALL PERMITS, FEES, LICENSES AND

INSPECTIONS. ALL WORK IS SUBJECT TO APPROVAL BY THE CODE

OFFICIAL AND ENGINEER. ALL CORRECTIONS SHALL BE MADE

WITHOUT EXTRA COSTS TO OWNER.

SYMBOL

DESCRIPTION

H

P

MD

SD

H

SYMBOL

DESCRIPTION

SYMBOL

DESCRIPTION

FOR

T

SP

FIRE DAMPERFD

SMOKE DAMPERSD

COMBINATION FIRE/SMOKE DAMPERFSD

POINT OF DISCONNECT SYMBOL

1. RECTANGULAR DUCT SHALL BE GALVANIZED G60 OR G90 GRADE SHEETMETAL FORMED AND FABRICATED IN

ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS-METAL AND FLEXIBLE FOR PRESSURE

CLASS OF 2” WG MINIMUM. 26 GAGE METAL MINIMUM.

2. ROUND DUCT SHALL BE GALVANIZED G60 OR G90 GRADE SHEETMETAL SPIRAL DUCTING FORMED IN

ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS-METAL AND FLEXIBLE FOR PRESSURE

CLASS OF 2” WG MINIMUM. DIE CAST OR WELDED ELBOWS AND FITTINGS MEETING THE SAME SPECIFICATION

ALLOWED. AT CONTRACTOR OPTION, LONGITUDE LOCK SEAM (SNAPPY) DUCT AND ADJUSTABLE FITTINGS ARE

ALLOWED ONLY ON RESTROOM EXHAUST. 26 GAGE METAL MINIMUM.

3. SEAL ALL DUCT SEAMS IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS-METAL AND

FLEXIBLE TABLE 1-2 SEAL CLASS B, MINIMUM.

4. DUCT CONNECTOR SHALL BE STANDARD SLIP 'S' AND DRIVE CONNECTOR OF METAL GAGE NOT LESS THAN

DUCT GAGE SPECIFIED IN #1. PROPRIETARY FLANGE CONNECTIONS SUCH AS WARD OR DUCT-MATE ARE

ENCOURAGED.

5. SUPPORT ALL DUCTING IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS-METAL AND

FLEXIBLE. NO EXCEPTIONS!

6. DUCT LINER SHALL BE 1" OWENS CORNING 'LINA-COOUSTIC' BRAND, OR EQUAL. INSTALL ACCORDING TO MFR.

RECOMMENDATIONS.

7. INSULATE ALL EXTERIOR (OUTDOOR) DUCTING WITH RIGID 2" FIBERGLASS INSULATION WITH SEALED

GALVANIZED CLADDING.

8. ALL RECTANGULAR ELBOWS TO CONTAIN SINGLE OR DOUBLE TURNING VEIN.

DUCT CONSTRUCTION SPECIFICATION

INSULATED DUCTWORK INCLUDES (2" THICKNESS/R-5 VALUE):

· ALL CONCEALED SUPPLY DUCT INSTALLED NEW ON THIS PROJECT.

LINED DUCTWORK INCLUDES (1" THICKNESS MINIMUM):

· ALL RETURN DUCT/PLENUM (AS SHOWN ON PLANS).

· ALL RETURN DUCT/PLENUM.

DUCT INSULATION/LINER REQUIREMENTS

1" FIBERGLASS

1,2,31/2" FIBERGLASSALL

PIPE SIZE

SERVICE OR

SYSTEM

MATERIAL

INSULATION THICKNESS NOTES:

DOMESTIC COLD WATER

DOMESTIC HOT WATER

(100-180 DEG F)

TYPE L COPPER, VIEGA PEX MODEL V5001 (INSIDE WALLS AND

CRAWLSPACE ONLY), PRO-PRESS

ALL 1,2,3

NATURAL GAS

BLACK T&C WITH BMI FITTINGS

WELDED STEEL SCH 40

<=2"

>2"

NONE

ALL

PIPE SIZE

ALL

N/A

SANITARY SEWER U/G

SANITARY SEWER A/G

CONDENSATE

SCHEDULE 40 PVC DWV, HUBLESS CAST IRON

ALL

ALL

ALL

NONE

N/A

NONE

N/A

NONE

N/A

SCHEDULE 40 PVC DWV, HUBLESS CAST IRON

SCHEDULE 40 PVC DWV

(FLEXIBLE TUBING NOT ALLOWED)

NOTES:

1. INSULATION TO BE OF HEAVY DENSITY BONDED FIBERGLASS WITH ALL SERVICE JACKET (WHITE). FITTING TO BE PVC ZESTON COVERS WITH FLEXIBLE INSULATION WRAP. SEAL

ALL JOINTS WITH SEALANT. K VALUE NOT EXCEEDING 0.27 BTU PER IN/H*FT^2*DEG F.

2. SEISMIC BRACE ALL PIPE GREATER THAN 2-1/2" ID PER LOCAL CODE.

3. ALL PIPING IN MECHANICAL ROOMS AND WATER SERVICES TO BE NSF RATED METALLIC PIPE. NO EXCEPTIONS.

GENERAL NOTE ALL: SEAL ALL NON RATED STRUCTURE PIPE PENETRATIONS INCLUDING DRAFT STOPS WITH SILICON OR FIRE RATED EXPANDING FOAM. SEAL ALL RATED PIPE

PENETRATIONS IN ACCORDANCE WITH CONTRACTOR SELECTED MFR FIRE CAULK SYSTEM (AND/OR FIRE COLLAR) AND MATCH RATING WITH SPECIFIC UL LISTING. PROVIDE

ENGINEER AND INSPECTOR FOR AHJ WITH SHOP DRAWING OF RATED ASSEMBLY PRIOR TO INSTALLATION.

* PROVIDE WRITTEN AND SIGNED REPORT BY CONTRACTOR FOR ALL SYSTEMS TESTED, TYPE OF TEST, DATE, PRESSURE, TIME START, TIME END, AND SYSTEM TESTED. SUBMIT TO

ENGINEER IN IOM SUBMITTAL.

PRESSURE TEST*

100 PSI AIR-30 MIN

100 PSI AIR-30 MIN

40 PSI AIR-60 MIN

20 PSI AIR-60 MIN

20 PSI AIR-60 MIN

VISUAL INSPECTION

PIPE MATERIAL AND INSTALLATION REQUIREMENTS

TYPE L COPPER, VIEGA PEX MODEL V5002 (INSIDE WALLS AND

CRAWLSPACE ONLY), PRO-PRESS

ALL WORK PERFORMED IN CONJUNCTION WITH THESE

DRAWINGS SHALL MEET ALL CURRENT APPLICABLE

BUILDING AND ENERGY CODES.

ALL WORK PERFORMED IN CONJUNCTION WITH THESE

DRAWINGS IS SUBJECT TO APPROVAL BY THE

AUTHORITY HAVING JURISDICTION (CODE OFFICIAL).

ALL ROOF PENETRATIONS SHALL BE PATCHED AND

SEALED, WITH WARRANTY FROM BUILDING ROOFING

CONTRACTOR.

THIS SET OF DOCUMENTS IS INTENDED FOR AHJ

REVIEW AND SHALL BE CONSIDERED AS

CONSTRUCTION DOCUMENTS. IT SHALL BE THE SOLE

RESPONSIBILITY OF THE CONTRACTOR TO

COORDINATE ALL CONDITIONS, EXISTING AND/OR NEW,

OF THE SITE AS WELL AS LOCATIONS, QUANTITIES,

TYPE AND STYLE OF ALL PRODUCTS PROVIDED, WITH

OWNER, PRIOR TO ORDERING OR INSTALLING.

GENERAL CONSTRUCTION NOTES

MEP ABBREVIATIONS

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

A/G ABOVE GRADE

B/G BELOW GRADE

CA COMPRESSED AIR

COND CONDENSATE DRAIN

CPCI CONTRACTOR PROVIDED CONTRACTOR INSTALLED

CPOI CONTRACTOR PROVIDED OWNER INSTALLED

CHWR CHILLED (HYDRONIC) WATER RETURN

CHWS CHILLED (HYDRONIC) WATER SUPPLY

CWR CONDENSER (HYDRONIC) WATER RETURN

CWS CONDENSER (HYDRONIC) WATER SUPPLY

DCW DOMESTIC (POTABLE) COLD WATER

DHW DOMESTIC (POTABLE) HOT WATER

DHWR DOMESTIC HOT WATER RETURN

EA ENTERING AIR

EC ELECTRICAL CONTRACTOR

EX EXHAUST

G-SAN GREASE SANITARY SEWER

GC GENERAL CONTRACTOR

HC HVAC CONTRACTOR

HWR HOT (HYDRONIC) WATER RETURN

HWS HOT (HYDRONIC) WATER SUPPLY

HP HIGH PRESSURE

IJS IN JOIST SPACE

LA LEAVING AIR

LP PROPANE GAS

MA MIXED AIR

MC MECHANICAL CONTRACTOR

MP MEDIUM PRESSURE

MPG MEDIUM PRESSURE NATURAL GAS

NG NATURAL GAS

OA OUTSIDE/OUTDOOR AIR

OPCI OWNER PROVIDED CONTRACTOR INSTALLED

OPOI OWNER PROVIDED OWNER INSTALLED

PC PLUMBING CONTRACTOR

RA RETURN AIR

RECT RECTANGULAR

SA SUPPLY AIR

SCR STEAM CONDENSATE RETURN

SAN SANITARY SEWER

SS STORM WATER SEWER

STM STEAM

SYS SYSTEM

TEMP TEMPERATURE

V VENT

POINT OF CONNECTION SYMBOL

POINT OF CONNECTION SYMBOL

M 1.1

M 1.2

M 1.3

M 1.0 FIRST FLOOR MECHANICAL DEMOLITION

SECOND FLOOR MECHANICAL DEMOLITION

THIRD FLOOR MECHANICAL DEMOLITION

MECHANICAL SCHEDULES AND DETAILS

FOURTH FLOOR MECHANICAL DEMOLITION

M 0.1

FIRST FLOOR MECHANICAL PLAN

SECOND FLOOR MECHANICAL PLAN

THIRD FLOOR MECHANICAL PLAN

FOURTH FLOOR MECHANICAL PLAN

M 1.5

M 1.6

M 1.7

M 1.4

TEST & BALANCE INSTRUCTIONS:

BALANCING SHALL BE PERFORMED BY A THIRD PARTY T&B CONTRACTOR. THE BALANCING

CONTRACTOR SHALL PERFORM AIR AND WATER BALANCE IN ACCORDANCE WITH MINIMUM

NEBB GUIDELINES AND REPORT THE FOLLOWING DATA:

1. OPERATING AMPERAGE MEASURED UNDER FULL LOAD.

2. MEASURED VOLTAGE AT EACH UNIT.

3. ESP OF EACH AIR MOVING EQUIPMENT.

4. TOTAL MEASURED AND ADJUSTED CFM RETURN AND SUPPLY AIR.

5. INITIAL PRESSURE DROP ACROSS FILTERS.

6. CFM GRILLES, REGISTERS , AND DIFFUSERS.

THE FOLLOWING PIECES OF EQUIPMENT SHALL RECEIVE TESTING & BALANCING TREATMENT:

A. FCU-1

B. FCU-2

C. FCU-3

D. FCU-4

E. FCU-5

F. FCU-6

G. FCU-7

H. FCU-8

MECHANICAL COVER SHEET

10-CBS M 0.0

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PROTECTION ENGINEERING

100 CREEK ROAD, SUITE 102

Phase

DRIPPING SPRINGS, TEXAS 78620

(512) 380-1988 Consultant POC

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

FOURFRONT DESIGN, INC

517 7TH STREET

RAPID CITY, SOUTH DAKOTA 57701

(605) 342-9470

POC: RAY DAWES

PHYSICAL SECURITY SPECIALIST:

EHRM INFRASTRUCTURE

UPGRADES AT THE EASTERN

COLORADO VA MEDICAL CENTER

AURORA, COLORADO

VA 554-21-700

Project Director

Revisions: Date: 4F PROJECT NO: 15.2226.30

OCT 18 2021 RD AZ

10.CBS

AutoCAD SHX Text P

CONSTRUCTION OF 90° ELBOWS CONSTRUCTION OF 45° ELBOWS

TYPICAL VOLUME DAMPER

HIGH EFFICIENCY TAKE-OFF

CONSTRUCTION OF BRANCH TAKEOFFS FROM MAIN

TYPICAL RECTANGULAR TRANSITION

C

L

ROUND 90° ELBOW

"W"

"W"

L

C

1 1/2W

ROUND BRANCH TAKEOFF

FLOW

SQUARE BRANCH TAKEOFF

ROUND 45° ELBOW

ROUND DUCT

TYPICAL RECTANGULAR TO ROUND TRANSITION

L

C

SQUARE 90° ELBOW

AIR

SQUARE 45° ELBOW

BRANCH

MAIN

FLOW

1 1/2W

"W"

"W"

"W"

"W"

AIR

"W"

"W"

MAIN

BRANCH

"W"

USE THIS DESIGN

WHERE ROUND 90°

ELS ARE SHOWN ON

PLANS

USE THIS DESIGN WHERE

SQUARE 90° ELS ARE

SHOWN ON PLANS OR IF

SPACE CONDITIONS DO

NOT PERMIT

INSTALLATION OF ROUND

90° ELLS

USE THIS DESIGN WHERE

ROUND 45° ELBOWS ARE

SHOWN ON PLANS

USE THIS DESIGN

WHERE ROUND

45° ELBOWS ARE

SHOWN ON PLANS

TURN

VANES,

SINGLE

SINGLE TURN VEIN 22 GAGE

SLOPE NOT TO

EXCEED 1" IN 4"

OPERATING SHAFT FOR

QUADRANT OR MOTOR.

HINGE

POINT

DOUBLE ACTING BLADES

CONNECTION LINKAGE

RECTANGULAR

DUCT

SLOPE NOT TO

EXCEED 1" IN 4"

L

C

FLOW

*45°

AIR

MAIN AIR DUCT

ACOUSTIC LINING WHERE

SHOWN ON FLOORPLAN

L.P. BRANCH DUCT

HAND VOLUME

DAMPER

*-EQUALS WIDTH OF BRANCH DUCT UP TO

12". 12" FOR ALL BRANCH DUCTS LARGER

THAN 12".

CHWS

CHWR

V-1

FAN

SST

VSMC

T-1T

PC

GENERAL FAN COIL NOTES:

NEW FAN COIL UNITS SHALL BE INTEGRATED INTO THE EXISTING

BAS/DDC.

MONITORED FAN COIL POINTS:

FAN SPEED: LOW, MEDIUM, AND HIGH

FAN STATUS

DISCHARGE AIR TEMPERATURE

CC VALVE

ZONE TEMPERATURE

SETPOINTS: EMERGENCY SHUTDOWN, ZONE COOLING SETPOINT

FAN COIL SEQUENCE OF OPERATION:

UNIT SHALL OPERATE ON A SCHEDULE AS SET BY ECC. FAN SHALL

RUN CONTINUOUSLY. FAN STATUS SHALL BE MONITORED AND AN

ALARM MESSAGE SHALL BE GENERATED IN THE EVENT THE UNIT

FAILS TO RUN. BETWEEN THE RANGE OF 70°-75° SPACE

TEMPERATURE, V-1 SHALL BE CLOSED. UPON RISE IN TEMPERATURE

ABOVE 75° V-1 SHALL MODULATE OPEN TO MAINTAIN 75° F.

TT

RA

FILTER

COOLING COIL

ROOM TEMPERATURE SENSOR,

WALL-MOUNTED 48" AFF.

CONTROLS KEY

DISCHARGE AIR TEMPERATURE

VARIABLE SPEED MOTOR CONTROLLER

PRIMARY CONTROLLER

TT

VSMC

PC

FAN START/STOP CONTROLLERSST

NETWORK TRUNK

NOTES:

1. INSTALL CONTROL VALVE BETWEEN UNION OR FLANGES.

2. PROVIDE CONCENTRIC REDUCERS BOTH SIDES OF CONTROL VALVE AS REQUIRED.

3. REPLACE UNION/FLANGE SET WITH A FLEXIBLE PIPE CONNECTOR WHERE EQUIPMENT ID SUPPORTED

OR SUSPENDED BY A SPRING ISOLATOR.

4. ARRANGEMENT SHOWN FOR FULL FLOW THROUGH COIL ON FAILURE.

V-1

MV

MV

MV

AIR FLOW

MANUAL AIR VENT

PRESSURE &

TEMPERATURE

TEST PLUG (TYP)

COIL

COIL DRAIN WITH

CAP AT LOWEST

POINT OF COIL

3/4" BRANCH

PIPING TO

EACH FCU

ISOLATION

VALVE (TYP)

THREE-WAY CONTROL

VALVE, NORMALLY

OPEN (SEE NOTE 1)

UNION (TYP)

BALANCING VALVE

CONNECT TO SUPPLY/RETURN

MAINS AS SHOWN ON PLANS

INSTALL MANUAL AIR VENT AT

HIGH POINT. USE PIPE STUB

WITH MINIMUM HEIGHT OF 4

PIPE DIAMETERS (TYP)

NOTES:

1. INSTALL CONTROL VALVE BETWEEN UNION OR FLANGES.

2. PROVIDE CONCENTRIC REDUCERS BOTH SIDES OF CONTROL VALVE AS REQUIRED.

3. REPLACE UNION/FLANGE SET WITH A FLEXIBLE PIPE CONNECTOR WHERE EQUIPMENT

ID SUPPORTED OR SUSPENDED BY A SPRING ISOLATOR.

4. ARRANGEMENT SHOWN FOR FULL FLOW THROUGH COIL ON FAILURE.

P

MV

MV

MV

MV

CONNECT TO SUPPLY/RETURN

MAINS AS SHOWN ON PLANS

INSTALL MANUAL AIR VENT AT

HIGH POINT. USE PIPE STUB

WITH MINIMUM HEIGHT OF 4

PIPE DIAMETERS (TYP)

UNION (TYP)

MANUAL AIR VENT

COMBINATION

UNION AND PT

PORT (TYP)

AIR FLOW

COIL

MANUAL AIR VENT

TWO-WAY PRESSURE

INDEPENDENT

CONTROL VALVE

ISOLATION

VALVE (TYP)

3/4" BRANCH

PIPING TO

EACH FCU

WYE STRAINER

GRILLE/REGISTER/DIFFUSER SCHEDULE

TAG NO. NECK SIZE TYPE MANUFACTURER & MODEL MATL/FINISH OPTIONS & ACCESSORIES

SR = SUPPLY REGISTER RG = RETURN GRILLE SD = SUPPLY DIFFUSER EG = EXHAUST GRILLE TG = TRANSFER GRILLE

NOTES:

RG-1

SD-1 SURFACE WHITE

1. CONTRACTOR TO PROVIDE ALL NECESSARY HARDWARE FOR MOUNTING TYPE LISTED ABOVE.

2. ALUMINUM CONSTRUCTION

1,2

SURFACE WHITE 1,2

18"x18" NAILOR 51DH-O HORIZONTAL (LONG) FRONT BLADES

NAILOR 5155H-O ALUMINUM HORIZONTAL (LONG) BLADES

GRD ID SCHEDULE

TAG STYLE

CFM

SD-1

NECK

SIZE

1415 18"x18"

1415RG-1 18"x18"

18"x18"

FAN COIL UNIT SCHEDULE

FCU

FCU-1 0.3 80 55 40,000 8.0 STULZ CEILAIR OHS-040-HC

1,2,3,4,5,6,7

EQUIPMENT

NO.

AIRFLOW

CFM

ESP

IN

EAT

°F

LAT

°F

CAPACITY

BTU/HR

COOLING

OPTIONS-ACCESSORIES

MANUFACTURER & MODEL

FLOWRATE

GPM

SERVING

RM

10-A1-223

FCU-2 10-A1-351

FCU-3 10-A2-214A

FCU-4 10-A2-308A

FCU-5 10-A3-243A

FCU-6 10-A3-335

FCU-7 10-A4-216

FCU-8 10-A4-343

NOTES:

1. DDC CONTROL (CONTROLLER BY TC CONTRACTOR).

2. DISCONNECT PROVIDED WITH DIVISION 26 CONTRACTOR.

3. 460 VOLT THREE PHASE VOLTAGE. PROVIDE TRANSFORMER FOR TC CONTRACTOR.

4. PROVIDE WITH SPRING VIBRATION ISOLATION AND ALL-THREAD HANGING RODS.

5. PROVIDE WITH FACTORY CONDENSATE PUMP.

6. PROVIDE WITH ECM FAN CONTROLLER.

7. MANUFACTURER AND MODEL SHOWN AS BASIS OF DESIGN. EQUALS ARE ALLOWED TO BE SUBMITTED FOR APPROVAL.

VOLT/PH/CY FLA

MCA

ELECTRICAL

MOCP

STULZ CEILAIR OHS-040-HC

STULZ CEILAIR OHS-040-HC

STULZ CEILAIR OHS-040-HC

STULZ CEILAIR OHS-040-HC

STULZ CEILAIR OHS-040-HC

STULZ CEILAIR OHS-040-HC

STULZ CEILAIR OHS-040-HC

460/3/60 2.7 3.4 15

460/3/60

460/3/60

460/3/60

460/3/60

460/3/60

460/3/60

460/3/60

1,2,3,4,5,6,7

1,2,3,4,5,6,7

1,2,3,4,5,6,7

1,2,3,4,5,6,7

1,2,3,4,5,6,7

1,2,3,4,5,6,7

1,2,3,4,5,6,7

2.7 3.4 15

2.7 3.4 15

2.7 3.4 15

2.7 3.4 15

2.7 3.4 15

2.7 3.4 15

2.7 3.4 15

0.3 80 551415

0.3 80 551415

0.3 80 551415

0.3 80 551415

0.3 80 551415

0.3 80 551415

0.3 80 551415

40,000 8.0

40,000 8.0

40,000 8.0

40,000 8.0

40,000 8.0

40,000 8.0

40,000 8.0

MECHANICAL SCHEDULES AND

DETAILS

10-CBS M 0.1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PROTECTION ENGINEERING

100 CREEK ROAD, SUITE 102

Phase

DRIPPING SPRINGS, TEXAS 78620

(512) 380-1988 Consultant POC

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

FOURFRONT DESIGN, INC

517 7TH STREET

RAPID CITY, SOUTH DAKOTA 57701

(605) 342-9470

POC: RAY DAWES

PHYSICAL SECURITY SPECIALIST:

EHRM INFRASTRUCTURE

UPGRADES AT THE EASTERN

COLORADO VA MEDICAL CENTER

AURORA, COLORADO

VA 554-21-700

Project Director

Revisions: Date: 4F PROJECT NO: 15.2226.30

OCT 18 2021 RD AZ

10.CBS

DUCT CONSTRUCTION DETAILS

M 0.1

SCALE: NTS

TWO-PIPE FAN COIL UNIT CONTROLS

M 0.1

SCALE: NTS

FAN COIL UNIT WITH 3-WAY CONTROL VALVE PIPING DETAIL

M 0.1

SCALE: NTS

FAN COIL UNIT WITH 2-WAY PRESSURE INDEPENDENT CONTROL VALVE PIPING DETAIL

M 0.1

SCALE: NTS

CHAIR STOR

A1-227

CHAIR STOR

A1-225

MULTIPURPOSE

(GOLDENROD)

A1-223

TELECOM

A1-225A

OFFICE

A1-214

OFFICE

A1-212

OFFICE

A1-210

OFFICE

A1-ST1

STAIR

A1-206

WOMEN'S RESTROOM

A1-220

A1-222

STOR

A1-218

MULTIPURPOSE

(CONEFLOWER)

A1-C06

CORRIDOR

ACCESS

MAINT.

ACCESS

A

C

C

E

S

S

ACCESS

MAINT.

MAINT.

M

A

I

N

T

M

A

I

N

T

A

C

C

E

S

S

M

A

I

N

T

A

C

C

E

S

S

ACCESS

MAINT.

ACCESS

MAINT.

A

C

C

E

S

S

M

A

I

N

T

ACCESS

MAINT.

T

T

T

T

T

T

T

10-WCHP7

EXISTING 20"x20' RETURN

DUCT AND GRILLE

(REMAIN)

EXISTING 18"x18" SUPPLY

DUCT AND DIFFUSER

(REMAIN)

EXISTING 1-1/4" CWR

(REMOVE AND CAP)

EXISTING 1-1/4" CWS

(REMOVE AND CAP)

EXISTING CAPPED

1-1/4" CHWR

EXISTING CAPPED

1-1/4" CHWS

EXISTING 1-1/4" CWR

(REMAIN)

EXISTING 1-1/4" CWS

(REMAIN)

EXISTING 3/4" COND

(REMAIN)

GENERAL:

REMOVE EXISTING HEAT PUMP.

RE-USE EXISTING DUCTING, POWER,

CONTROLS, AND CONDENSATE

PIPING AS POSSIBLE. EXISTING

THERMOSTAT TO REMAIN. REMOVE

EXISTING HP DDC CONTROLLER, TO

BE INSTALLED ON NEW FCU.

REMOVE AND CAP EXISTING

CONDENSER WATER PIPING.

TEMPORARILY RELOCATE

EQUIPMENT ABOVE CEILING TILES AS

NECESSARY FOR ACCESS DURING

DEMOLITION.

A1-C13

CORRIDOR

A1-309

MED ROOM

A1-307

OFFICE

A1-123

STORAGE

A1-308

RECEPTION

A1-338

EXAM

A1-315

WAIT

A1-C16

CORRIDOR

A1-351

TELECOM

A1-353

ELEV

MACHINE

ROOM

A1-ST2

STAIRA1-305

STORAGE

A1-303

CLEAN SUPPLY

A1-301

STORAGE

A1-398

OFFICE

A1-C25

A1-375

OFFICE

A1-373

OFFICE

A1-371

OFFICE

A1-369

OFFICE

A1-367

OFFICE

A1-365

COPY/PRINT

A1-C14

CORRIDOR

10 - TU1 - 1.9

ACCESS

ACCESS

ACCESS

M A

I N

T

M A

I N

T

E

MAINT.

M A

I N

T

ACCESS

(TYP-3)

A C

C E

S S

(TYP)

A C

C E

S S

A C

C E

S S

A C

C E

S S

MAINT.

M A

I N

T

A C

C E

S S

A C

C E

S S

MAINT.

M A

I N

T

M A

I N

T

MAINT.

A C

C E

S S

ACCESS

ACCESS

M A

I N

T

ACCESSACCESS

M A

I N

T

A C

C E

S S

T

T

T

T

T

T

EXISTING CWR

(REMOVE AND CAP)

10-WCHP4

EXISTING 14"x14" SUPPLY

DUCT AND DIFFUSER

(REMAIN)

EXISTING 14"x14" RETURN

DUCT AND GRILLE

(REMAIN)

EXISTING CWS

(REMOVE AND CAP)

EXISTING 1-1/2" CWS

(REMAIN)

EXISTING 1-1/2" CWR

(REMAIN)

EXISTING

1-1/2" CHWR

EXISTING

1-1/2" CHWS

T

EXISTING 3/4" COND

(REMAIN)

GENERAL:

REMOVE EXISTING HEAT PUMP.

RE-USE EXISTING DUCTING,

CONTROLS, AND CONDENSATE PIPING

AS POSSIBLE. REMOVE EXISTING 208V

POWER AND CONDUIT. EXISTING

THERMOSTAT TO REMAIN. REMOVE

EXISTING HP DDC CONTROLLER, TO

BE INSTALLED ON NEW FCU. REMOVE

AND CAP EXISTING CONDENSER

WATER PIPING TO BRANCH.

TEMPORARILY RELOCATE EQUIPMENT

ABOVE CEILING TILES AS NECESSARY

FOR ACCESS DURING DEMOLITION.

UP

A1-233

MULTIPURPOSE

(BLUE VERVAIN)

A1-229A

CHAIR STOR

A1-231

MULTIPURPOSE

(BUTTERFLY WEED)

A1-229

MULTIPURPOSE

(DAISY)

A1-225B

CHAIR STOR

A1-227

CHAIR STOR

A1-225

MULTIPURPOSE

(GOLDENROD…

This is the start of the file's text. The full file is on GovTribe.