Attachment 01 - Technical Requirement Documents (TRDs).pdf

PDF 3 MB Posted

Attached to
Industrial Plant Equipment Federal contract opportunity
Solicitation number
QSDM-J3-223010-A
Issued by
GSA Federal Acquisition Service

View the file

Other files for this federal contract opportunity

Other files attached to Industrial Plant Equipment, newest first.
File Type Posted
SF30 Amendment 002 of Solicitation.pdf PDF
ID47QSHE22K0001_RFQ Industrial Plant Equipment (2).pdf PDF
Questions-Answers IPE.docx DOCX document
SF30 Amendment 001 of Solicitation.pdf PDF
Attachment 02 - MIL STD 129R.pdf PDF
Exhibit 02 - Vendor Response Document Spreadsheet.xlsx XLSX spreadsheet
Exhibit 01 - Vendor Response Document (VRD).pdf PDF
Exhibit 04 - OR EQUAL self certification.pdf PDF
Exhibit 03 - 1449.pdf PDF
ID47QSHE22K0001_RFQ Industrial Plant Equipment.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Technical Requirement Documents (TRDs)

CLIN 1:

ITEM NOUN: CUTTING SYSTEM, WATER JET

NSN: 3419015250135

REQUISITION: FE633180590326

Specifications/Technical Characteristics:

● MAXIMUM

OPERATING

PRESSURE

● MOUNTING TYPE

● CURRENT TYPE

● ELECTRIC MOTOR

HORSEPOWER

RATING

● TABLE OVERALL

LENGTH

● TABLE OVERALL

WIDTH

● TABLE

LONGITUDINAL

TRAVEL

● TABLE CROSS

TRAVEL

● PHASE

50000.0 POUNDS PER SQUARE INCH ABSOLUTE

FLOOR

AC

30.0

126.000 INCHES NOMINAL ; up to 2"-6" variance

65.000 INCHES NOMINAL ; up to 2"-6" variance

100.000 INCHES NOMINAL ; up to 2"-6" variance

55.000 INCHES NOMINAL ; up to 2"-6" variance

THREE

● SPECIAL FEATURES

▪ 380-440 VAC, 50-60HZ / 3 PHASE;

▪ 30HP AT 50,000PSI;

▪ 3/4 YD HOPPER;

▪ SYS DRIVE 1/2 HP;

▪ OPERATES UNATTENDED;

▪ NOISE LEVEL BELOW 80 DBA FOR SUBMERGED

CUTTING;

▪ SPEED 200 IPM;

▪ CNTRL CONSOLE 110V;

▪ REMOTE/LOCAL CONTROL

● FREQUENCY IN

HERTZ 50.0 AND 60.0

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

1/70

• Maximum Standard size Material to be cut 96"x48"

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

If not specified within the characteristics of the NSN, please provide the following information:

● The existing source power available at the facility is o Volt: 380-440 VAC o Phase: 3 o Frequency: 60HZ

● The machine must fit through a doorway with the following dimensions:

o Width: 12’ o Height: 11’

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: 20’ o Length: 20’

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional options or accessories that are not part of the standard package or already listed above in the characteristics data.”

2/70

CLIN 2:

ITEM NOUN: FURNACE, HEAT TREATING

NSN: 3424016630736

REQUISITION: FE302911300015

Specifications/Technical Characteristics:

MAXIMUM OPERATING TEMP 2000.0 DEG FAHRENHEIT

OPERATING TEMP RANGE +1400.0 TO 2000.0 DEG FAHRENHEIT

TEMP CONTROL DEVICE TYPE AUTOMATIC

WATTAGE RATING IN KILOWATTS 60.0

PART NAME ASSIGNED BY CONTROLLING AGENCY FURNACE,HEAT TREATING

VOLTAGE IN VOLTS 110.0

Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist

235 Byron Street, (Bldg. 300) Suite 19A

Robins AFB, GA 31098-1813

3/70

If not specified within the characteristics of the NSN, please provide the following information:

● The existing source power available at the facility is o Volt: 480/230__ o Phase: __3__ o Frequency: _60___ Hertz (Hz)

● The machine must fit through a doorway with the following dimensions:

o Width: _7’10”____ o Height: _9’____

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width:__9’__ o Length: _9’___

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional options or accessories that are not part of the standard package or already listedabove in the characteristics data.”

4/70

CLIN 3:

ITEM NOUN: CNC MACHINING CENTER, VERTICAL

NSN: 3408014242101

REQUISITION : FE633101550022

Specifications/Technical Characteristics:

Table Size: 26x14; There can be a variance on the table but it needs to have the same surface parameter. Ex:

52x18 50x20.

XYZ Travel 20x16x20; There can be a 2" XYZ variance to match the table size.

10hp Continuous Operation No 40 Spindle Taper 0-7500rpms Xyz Rapid Traverse at 500ipm Max Cutting at 200ipm Tool Changer Capacity: 20+ Power Requirements Are 200-250 VAC, 3 Phase, 30amps, 10kVa Fanuc/Yasnac Compatible 32 Bit processor Air/Oil Injection Bearing Lube Liquid Cooling A Axis Available Meets Partial Mil-M-80255 Specification

● One (1) hard copy and one (1) electronic copy of technical data shall be provided with the machine.

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A

5/70

● The existing source power available at the facility is o Volt: 480V o Phase: 3 o Frequency: 60HZ

● The machine must fit through a doorway with the following dimensions:

o Width: 12’ o Height: 11’

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: 27’ o Length: 25’

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional options or accessories that are not part of the standard package or already listed

6/70

CLIN 4:

ITEM NOUN: LATHE, ENGINE

NSN: 3416014862331

REQUISITION: FE633180590327

MOUNTING

TYPE FLOOR

ACDC CURRENT TYPE AC

ASHK ELECTRIC MOTOR HORSEPOWER RATING 30.000

ATJK POWER SOURCE ELECTRIC MOTOR

BTSX MAXIMUM BAR STOCK DIAMETER

ACCOMMODATED 2.500 INCHES

BTSY MAXIMUM CHUCKING DISTANCE OVER

UNIVERSAL CARRIAGE 34.000 INCHES

BTTB SPINDLE SPEED RANGE IN RPM +0.0/+3400.0

BTTD RATED SWING 30.000 INCHES

NOMINAL (+/- 2”)

BTTH MAXIMUM DISTANCE FROM SPINDLE NOSE TO

TURRET FACE 33.500 INCHES

BTTR TURRET CARRIAGE LONGITUDINAL TRAVEL 44.000 INCHES

NOMINAL (+/- 2”)

BTTS TURRET CARRIAGE CROSS TRAVEL 12.000 INCHES

NOMINAL (+/- 2”)

BTTT TURRET CARRIAGE FEED TYPE POWER

BTTZ TURRET POSITION QUANTITY 12 +

ELEC VOLTAGE IN VOLTS 200.0 AND 250.00

FAAZ PHASE THREE

FREQ FREQUENCY IN HERTZ

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Avery Hall, Equip. Specialist

7/70 o Volt: 200V-250V o Phase: 3 o Frequency: 60HZ

● The machine must fit through a doorway with the following dimensions:

o Width: 12’ o Height: 11’

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional

8/70

CLIN 5:

ITEM NOUN: BENDING MACHINE, PIPE

NSN: 3441014842569

REQUISITION: FE446060060070

● Floor Mounted

● Hand operated hydraulic

● Capacity o Tube: 1.5 in outer diameter, 0.065 in wall thickness o Pipe: 1.00 in IPS, schedule 40

● Center line radius: 8.00 in max

● Max bend arm: 195 degrees

● Max over-mandrel tube length: 10 ft

● Dimensions:

o Width: 40.00 in o Length: 144.00 in o Height: 40.00 in o Overall dimensions can have a 6" variance as long as they fit through the door and fit the available space listed on page 2 below.

● Accessories:

o Set of 20 mandrels 0.375 in OD to 1.50 in OD o Set of 6 mandrel rods o Set of 9 clamp blocks 0.375 in OD to 1.50 in OD o Set of 9 side blocks 0.375 in OD to 1.50 in OD o Wrench Set

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist

9/70 o Volt: __ __220____ o Phase: ___3___ __ o Frequency: _____N/A____ Hertz (Hz)

● The machine must fit through a doorway with the following dimensions:

o Width: _____71”____ o Height: ____79”_____

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: _____14ft____ o Length: ____20 ft agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional

10/70

CLIN 6:

ITEM NOUN: CNC MACHINING CENTER

NSN: 3408014715036

REQUISITION: FE633180590325

● GEAR DRIVEN

● X AXIS 50.0 IN.

● Y AXIS 20.0 IN.

● Z AXIS 25.0 IN.

● SPINDLE NOSE TO TBL MIN 4/29 MAX IN.

● TABLE: 52.0 IN. LONG X 18.0 IN. WIDE

(There can be a 2” variance on the table but it needs to maintain the same surface parameter. Ex:

52x18 50x20)

● MAX WGT ON TBL: 3,500 LBS

● SPNDL 40 TAPER

● SPNDL SPEED: 0 TO 7500 RPM;

● 2 SPEED; GEARED HEAD; LIQUID COOLED; 15HP; 11.0KW;

● MAX CUTTING: 300IPM;

● TOOL CHGR CAP. 20 W/OPT OF 32;

● MAX TOOL DIA: 3.5 IN.;

● MAX TOOL WGT: 12 LBS

● 380-480 VOLTS AC

● TOOL CHGR TYPE CT-40 OR BT-40

● AIR REQUIRED 4 SCFM, 100 PSI, (113 LPM, 6.9 BAR)

● One (1) hard copy and one (1) electronic copy of technical data shall be provided with the machine.

11/70 o Volt: 480V o Phase: 3 o Frequency: 60HZ

● The machine must fit through a doorway with the following dimensions:

o Width: 12’ o Height: 11’

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional options or accessories that are not part of the standard package or already listed above in the

12/70

CLIN 7:

ITEM NOUN: LATHE, ENGINE

NSN: 3416015237438

REQUISITION: FE468691150074

Specifications/Technical Characteristics:

● PART NAME ASSIGNED BY CONTROLLING AGENCY LATHE, CNC, TOOLROOM

● MOUNTING TYPE FLOOR

● DESIGN TYPE PLAIN

● PERFORMANCE TYPE STANDARD DUTY

● PURPOSE FOR WHICH DESIGNED GENERAL

● BED TYPE SOLID

● RATED SWING 16.000 INCHES NOMINAL

● SWING OVER CROSS SLIDE 8.500 INCHES NOMINAL

● CENTER TO CENTER DISTANCE 30.000 INCHES NOMINAL

● HOLLOW SPINDLE HOLE SIZE 2.310 INCHES NOMINAL

● CARRIAGE LONGITUDINAL FEED OPERATI METHOD HAND AND POWER

● CARRIAGE CROSS FEED OPERATION METH HAND AND POWER

● ELECTRIC MOTOR HP RATING 7.500

● CURRENT TYPE AC

● VOLTAGE IN VOLTS 240.0

● FREQUENCY IN HERTZ 60.0

● PHASE SINGLE OR THREE

SPECIAL FEATURES -HEAD STOCK DRIVE TYPE DIRECT PULLEY

-VARIABLE SPINDLE SPEED;

-SPINDLE NOSE A2-5;

-MAX SPINDLE SPEED 1800RMP

● One (1) hard copy and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

13/70 o Volt: __ ___220/440___ o Phase: ______3 __ o Frequency: _____60____ Hertz (Hz)

● The machine must fit through a doorway with the following dimensions:

o Width: ____95”_____ o Height: ___120”______

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: _____96”___ o Length: ____ 96”____

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional options or accessories that are not part of the standard package or already listed

14/70

CLIN 8:

ITEM NOUN: FURNACE, HEAT TREATING

NSN: 3424012992202

REQUISITION: FE660611330176

● 24.0 IN. HT BY 24.0 WD BY 36.0 IN. LG INSIDE (inside dimensions can be exceeded by 2”)

● DUAL CHAMBER

● UPPER CHAMBER2300 DEG F MAX

● LOWER CHAMBER 1250 DEG F MAX

● 230/460 V

● 3 PHASE

● 65 KW

● UPPER DOOR VERTICAL OPEN W/MANUAL LIFT

● LOWER DOOR HORIZONTAL SWING OPEN MANUAL OPEN

● TEMP CONTROL 110-115 AC INDEPENDENT OF EACH OTHER

● LOWER CHAMBER HAS CIRCULATION FAN AND STLS STEEL LINER

Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the

Shipping address for electronic technical data packages is:

15/70 o Volt: __480_ o Phase: __3_ o Frequency: __65KW_

● The machine must fit through a doorway with the following dimensions:

Preferred Option: Double Door way RM C1-2 easiest route with least amount of obstacles o Width: __12_(hangar door) o Height: __15_ o Width: ___ o Height: ___

● Available floor space for equipment width by length to include required operator workspace and

OSHA required access clearances to service panels.

o Width: __20_ o Length: __20_

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional options or accessories that are not part of the standard package or already listed

16/70

CLIN 9:

ITEM NOUN: Furnace, Heat treating

NSN: 3424016518905

REQUISITION: FE520980470207

● Dual chamber convection design

● Chamber size o Width: 18.00 in o Height: 12.00 in o Depth: 48.00 in

● Temperature range:

o Lower chamber: 400-1200° F o Upper chamber: 200-500° F

● Independent programmable chamber temperature controllers

● Manually operated stainless steel roll-away quench tank with mechanical agitation and temperature monitoring

● Power: 36 kW o Lower chamber 24kW o Upper chamber: 12kW

● Voltage: 480/240/208

● Phase: 3

● Frequency: 60 Hz

● Overall Dimensions (Can have a variance of 6” in any direction):

o Width: 60.00 in o Length: 104.00 in o Height: 77.00 in

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist

17/70 o Volt: __ __480____ o Phase: ___3___ __ o Frequency: _____60____ Hertz (Hz)

● The machine must fit through a doorway with the following dimensions:

o Width: ____10_____ o Height: ___15______

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: ___100+ ft______ o Length: ___100+ ft______ agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional options or accessories that are not part of the standard package or already listed

18/70

CLIN 10:

ITEM NOUN: FURNACE, HEAT TREATING

NSN: 3424016705380

REQUISITION: FE250081620032

● Voltage: 240 or 460 Volts

● Phase: 60 Hz

● Camber Dimensions: 36” H x 36” W x 36” L

● Overall Dimensions: 136” H x 65” W x 65” L (overall dimensions can vary by 6” as long as can fit through the door and fit the available space as specified on the second page).

● Power: 50 KW

● Temperature Range: 200ºF to 1600ºF

● One (1) hard copy and one (1) electronic copy of technical data shall be provided with the machine.

19/70 o Volt: __480__ o Phase: _3____ o Frequency: _60__ Hertz (Hz) o Air Supply: _120 _PSI

● The machine must fit through a doorway with the following dimensions:

o Width: __8 Feet_ o Height: __9 Feet_____

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: __20 Feet______ o Length: __20 Feet_____

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional options or accessories that are not part of the standard package or already listed above in the

20/70

CLIN 11:

ITEM NOUN: MILLING MACHINE, VERTICAL

NSN: 3417015235742

REQUISITION: FE468691160004

Specifications/Technical Characteristics:

● Floor Mounted

● Electric Motor

● Motor Horsepower: 7.5 HP

● Voltage: 240/420

● Frequency: 60 Hz

● Head type: stationary

● Table type: fixed bed

● Table length: 36.0 in

Table Width: 12.0 in (Table size can vary by 2”)

● Table longitudinal travel: 16.00 in

● Table cross travel: 12.00 in

● Table vertical travel: 10.00 in

● Max weight on table: 550 lb

● Spindle type: fixed

● Spindle taper: 40

● Spindle speed: 6000 RPM max

● Distance spindle to table: 4.0 to 14.0 in

● CNC

● 10+ pocket automatic tool changer

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

21/70 o Volt: __ ___220/440___ o Phase: ______3 __ o Frequency: _____60____ Hertz (Hz)

● The machine must fit through a doorway with the following dimensions:

o Width: ____95”_____ o Height: ___120”______

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: _____120”___ o Length: ____ 120”____

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional options or accessories that are not part of the standard package or already listed

22/70

CLIN 12:

ITEM NOUN: MILLING MACHINE, VERTICAL

NSN: 3417015236521

REQUISITION: FE302993370009

Specifications/Technical Characteristics:

MOUNTING

TYPE FLOOR

WIDTH 10.500 INCHES NOMINAL

LENGTH 57.750 INCHES NOMINAL

Overall Dimensions: Can be exceeded by 6" inches

CURRENT TYPE AC

HEAD TYPE STATIONARY

ELECTRIC MOTOR

HORSEPOWER RATING 7.500

POWER SOURCE ELECTRIC MOTOR

TABLE TYPE FIXED BED

TABLE LONGITUDINAL

TRAVEL 40.000 INCHES NOMINAL (up to 2" variance allowed)

TABLE CROSS TRAVEL 16.000 INCHES NOMINAL (up to 2" variance allowed)

SPINDLE TYPE FIXED

TABLE VERTICAL

TRAVEL 16.000 INCHES NOMINAL (up to 2" variance allowed)

MAXIMUM DISTANCE

FROM SPINDLE NOSE

TO WORKING SURFACE

20.000 INCHES

FEATURES PROVIDED COMPUTER NUMERICAL CONTROL

PART NAME ASSIGNED

BY CONTROLLING

AGENCY

MILL, CNC, TOOLROOM

23/70

VOLTAGE IN VOLTS 208.0 AND 240.0

PHASE SINGLE OR THREE

SPECIAL FEATURES

TAPER SIZE 40; MAX SPINDLE SPEED 4000 RPM;

POWER 240V AT 40 AMP OR 208V AT 25 AMP;

MINIMUM DISTANCE SPINDLE NOSE TO TABLE

4.0 IN.;OPTIONAL 10 OR 20 POCKET AUTOMATIC

TOOL CHANGER

● One (1) hard copy and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

If not specified within the characteristics of the NSN, please provide the following information:

● The existing source power available at the facility is o Volt: _240 o Phase: __Single_ o Frequency: __60__ Hertz (Hz)

● The machine must fit through a doorway with the following dimensions:

o Width: __160”______ o Height: __90”___

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: _108” ___ o Length: 108”__

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional options or accessories that are not part of the standard package or already listed

24/70

CLIN 13:

ITEM NOUN: LATHE, ENGINE

NSN: 3416015237893

REQUISITION: FE633180590322

● CURRENT TYPE AC

● CENTER TO CENTER DISTANCE 48.000 INCHES NOMINAL

● PERFORMANCE TYPE STANDARD DUTY

● PURPOSE FOR WHICH DESIGNED GENERAL

● DESIGN TYPE PLAIN

● ELECTRIC MOTOR HORSEPOWER RATING 12.000

● BED TYPE SOLID

● ELECTRIC MOTOR QUANTITY 3

● RATED SWING 19.000 INCHES NOMINAL

● SWING OVER CROSS SLIDE 11.100 INCHES NOMINAL

● HOLLOW SPINDLE HOLE SIZE 2.310 INCHES NOMINAL

● CARRIAGE LONGITUDINAL FEED OPERATION

METHOD HAND AND POWER

● CARRIAGE CROSS FEED OPERATION METHOD HAND AND POWER

● CRITICALITY CODE JUSTIFICATION FEAT

● VOLTAGE IN VOLTS 208.0 AND 240.0

● PHASE SINGLE OR THREE

● SPECIAL FEATURES

▪ HEADSTOCK DRIVE TYPE DIRECT

PULLEY;

▪ VARIABLE SPINDLE SPEED;

▪ SPINDLE NOSE A2-5;

▪ MAX SPINDLE SPEED 1800RPM;

▪ 240V AT40 AMP/208V AT 25 AMP

● FREQUENCY IN HERTZ 60.0

● CENTER TO CENTER DISTANCE 48.000 INCHES NOMINAL

● MOUNTING TYPE FLOOR

● One (1) hard copy and one (1) electronic copy of technical data shall be provided with the machine.

25/70 o Volt: 240V/208V o Phase: 3 o Frequency: 60HZ

● The machine must fit through a doorway with the following dimensions:

o Width: 12’ o Height: 11’

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional

26/70

CLIN 14:

ITEM NOUN: LATHE, ENGINE

NSN: 3416015237893

REQUISITION: FE302051550060

● Motor Quantity: 3

● Motor Horsepower: 12 HP

● Voltage: 208/240

● Phase: 1/3

● Frequency: 60 Hz

● Carriage Longitudinal Feed: hand or power

● Carriage Cross Feed: hand or power

● Center to Center: 48.00 in

● Swing: 19.00 in

● Swing over cross slide: 11.10 in

● Max cutting diameter: 16.00 in

● Hollow spindle hole size: 2.31 in

● Spindle nose: A2-5

● Max spindle speed: 1800 RPM

● Headstock Drive type: direct pulley

● Dimensions:

o Width: 56.00 in o Length: 104.00 in o Height: 79.00 in

Overall dimensions can vary by 6" in any direction.

See page 3 below for required accessories.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist

27/70 o Volt: __208___ o Phase: ___3___ o Frequency: __60__ Hertz (Hz)

● The machine must fit through a doorway with the following dimensions:

o Width: __10.5___Ft o Height: __10____Ft_

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: _12______Ft o Length: __25______Ft agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional

See below page for required accessories.

Accessories required with unit to meet mission requirements are as follows:

- Computer Numerically Controlled

- Ethernet Interface, USB port and Power Failure Detection Module

- 4 Station Automatic Tool Turret: 3/4" (20 mm) turning tools

28/70

- 10" (254 mm) Manual 3-Jaw Scroll Chuck; hard top reversible jaws, A2-6 mount; 2500 rpm max.

rating, 3.0" (76 mm) through bore

- Manual Tailstock with MT4 manual quill

- Quick-Change Tool Post; 2 position, 4 each 3/4" turn/face, 1 each 1.0" boring bar holder and T-nut

- Synchronized Tapping Capability

- Remote Jog Handle with LCD 2.8" color graphic display, 11-button keypad, triple-knob motion-control with infinite variable jog speeds, and built-in LED inspection light

- Spindle Orientation: Accurate positioning to 0.5 degrees

- Electronic Handwheels: For the X and Z axes; mounted to a pendant outside of the enclosure.

Allows for manual positioning of the cross slide and saddle with easy-to-operate handwheels.

- Coolant Pump Kit, 1/4 hp (186 W), 20-gallon (76 liter) tank

- Chip Enclosure

- Turret Cross-Slide, Tooling Ready

- X & Z Axis - Linear way construction

- Max Swing - 20” (508 mm)

- Max Cutting Dia. - 16” (406 mm)

- Max Cutting Length - 48” (1219 mm)

- Distance between Centers - 48” (1219 mm)

- Travel - X Axis 8” (203 mm), Z Axis 30” (762 mm)

- Rapid traverse rate - 450 IPM (11.4 m/min) X & Z

- Spindle Motor - 10 HP (7.5 kW) Vector Drive

- Maximum spindle speed - 1,800 RPM, 108 ft-lb @ 355 rpm

- Spindle Nose - A2-6

- Chuck - 8" (203 mm) Manual 3-Jaw Scroll Chuck (optional)

- Spindle Bore Dia. - 3.00”

- Accuracy, positioning - +/- .0008”

- Accuracy, repeatability - +/- .0004”

- Footprint (Not to Exceed) - 101” L x 54” D x 79” H

- Max Weight (Not to Exceed) - 5,900 lbs.

29/70

CLIN 15:

ITEM NOUN: FLARING AND BEADING MACHINE, TUBE

NSN: 3441005288629

REQUISITION: FE282382910151

● Bench mounted

● Electric Motor

● Motor Horsepower: 0.5 HP

● Voltage: 220/440 V

● Frequency: 60 Hz

● Phase: 3

● Pneumatically operated jaws

● 2 Spindle speed

● Flaring: 0.125 to 2.0 in OD

● Beading: 0.25 to 1.5 in OD

● Squaring and deburring ranges: 0.125 to 2.0 in OD

● Single lap flare type

BENCH MTD; 0.125 TO 2 IN. FLARE 0.25 TO 1.5 IN. BEAD SIZE RANGES; FOR 0.125 TO

2 IN. EA BURR AND SQ SIZE RANGES; 2 SPINDLE SPEED; SINGLE LAP FLARE TYPE;

PNEUMATICALLY OPER JAWS; ELEC MOTORS 0.5 HP AC 220 440V 60 HZ 3 PH

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist

30/70 o Volt: __ _220_____ o Phase: __3ph____ __ o Frequency: ____60_____ Hertz (Hz)

● The machine must fit through a doorway with the following dimensions:

o Width: ____4’_____ o Height: ____80”_____

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels. Mounts on top of bench o Width: ___N/A_____ o Length: __N/A______ agency.

Note 2: We the USAF do not include installation, training, tooling or any additional options that are not part of the standard package in the above characteristics data.

31/70

CLIN 16:

ITEM NOUN: FLARING MACHINE, TUBE

NSN: 3441004908740

REQUISITION: FE466472650146

● Pneumatically Powered

● Double Lap Flaring Capacity: 0.125 in. to 0.5 in. for non-ferrous metals

● Double Lap Flaring Capacity: 0.125 in. to 0.375 in. for ferrous metals

● Air Supply: 100 PSI

● One (1) hard copy and one (1) electronic copy of technical data shall be provided with the machine.

32/70 o Volt: ___480____ o Phase: __3____ o Frequency: __60___ Hertz (Hz) o Air Supply: 120 PSI

● The machine must fit through a doorway with the following dimensions:

o Width: 10 FT o Height: 16 FT

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: 6 FT o Length: 6 FT agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional

33/70

CLIN 17:

ITEM NOUN: LATHE, ENGINE

NSN: 3416015479285

REQUISITION: FE481172970007

● Screw Type

● Headstock drive type: Geared Head

● Electric motor: 10 HP

● Voltage: 230/460 V

● Phase: 3

● Frequency: 60.0 Hz

● Spindle speed quantity: 3

● Spindle speed: 0 to 3250 RPM

● Spindle hole diameter: 1.650 in

● Center to center: 25.00 in

● Cross travel: 9.8 in

● Top travel: 9.8 in

● Quill travel: 5.7 in

● Quill diameter: 2.8 in

● Rated swing: 13.00 in

● Actual swing over bed: 13.75 in

● Swing over cross slide: 7.750 in

● Carriage feed operation: power

● Thread change quantity: 56

● Thread quantity range: 2.0 to 56.0 per inch machine. 1 Hard copy Technical data available. Still in Equipment Power Box No digital data.

May be purchased from clausing-industrial.com

34/70 o Machine specifications : Volt: __ __230/440____ o Phase: ___3___ __ o Frequency: ______60___ Hertz (Hz)

● The machine must fit through a doorway with the following dimensions:

o Width: ___41”______ o Height: __72”_____on pallet__

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: ___96”______ o Length: ___144”______

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

Note 2: We the USAF do not include installation, training, tooling or any additional options that

35/70

CLIN 18:

ITEM NOUN: SAW, BAND, METAL CUTTER

NSN: 3405003519704

REQUISITION: FE446062080006

Specifications/Technical Characteristics:

MOUNTING FLOOR

CURRENT TYPE AC

FREQUENCY

RATING

60.0 HERTZ NOMINAL

ACCESSORY

COMPONENTS

AND QUANTITY

ADAPTERS,SAW GUIDE,90 DEG ANGLE,1SET;BELTS,DRIVE,1 SET;CHIP BLOWER

AND PUMP,1;CIRCLE CUTTING ATTACHMENT,1;CUT-OFF-MITRE

ATTACHMENT,1;GUIDES,ABRASIVE BAND,FOR 1 IN.W BANDS,1 SET;GUIDES,FILE

BAND,FOR 1/4 AND 1/2 IN W.BAND,1 SET;GUIDE,SAW BLADE,W/BALLBEARING

BACK-UP ROLLER,1/8,3/16,1/4,3/8,1/2,3/4,AND 1 IN.W SAW BLADES,1

SET;JAW,WORKHOLDING,1;LIGHT,TABLE,SHIELDED,1;PENCIL,ETCHING,1;GRIP

FENCE,1

FRAME TYPE RIGID

VOLTAGE RATING 220.0 VOLTS MINIMUM AND 440.0 VOLTS MAXIMUM

FEED METHOD WORK INTO CUTTING BAND

HORSEPOWER

RATING

2.000

THROAT DEPTH 36.000 INCHES NOMINAL

BRAKING

FACILITY

NOT INCLUDED

DRIVE METHOD ELECTRIC MOTOR

TABLE LENGTH 26.000 INCHES NOMINAL

TABLE WIDTH 26.000 INCHES NOMINAL

A 2" tolerance on the table length OR width is allowed, but not both dimensions (ie. 24" x 26" or 26” x 24”).

ELECTRIC

MOTOR

QUANTITY

TABLE TYPE TILTING

TABLE RIGHT TILT

ANGLE IN DEG

45.0

TABLE LEFT TILT

ANGLE IN DEG

5.0

BAND TYPE FOR

WHICH DESIGNED

FILE OR SAW BLADE

36/70

FILE MAXIMUM

WIDTH

ACCOMMODATED

0.500 INCHES

BLADE MAXIMUM

WIDTH

ACCOMMODATED

1.000 INCHES

VISE NOT PROVIDED

DISTANCE

BETWEEN GUIDE

AND TABLE

12.000 INCHES NOMINAL

CUTTING SPEED

RANGE

+50.0 TO 4500.0 FEET PER MINUTE

INFINITE CUTTING

SPEED FEATURE

PROVIDED

POWER FEED

FEATURE

PROVIDED

BUILT-IN

COOLANT

SYSTEM

NOT INCLUDED

INTEGRAL BUTT

WELDER

INCLUDED

INTEGRAL

GRINDER

INCLUDED

PHASE THREE

NONDEFINITIVE

SPEC/STD DATA

3 CLASS AND 3 SIZE

Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist

235 Byron Street, (Bldg. 300) Suite 19A

37/70

● The existing source power available at the facility is o Volt: 208V o Phase: 3 o Frequency: 60 Hertz (Hz)

● The machine must fit through a doorway with the following dimensions:

Preferred Option: Double Door way RM C1-2 easiest route with least amount of obstacles o Width: 72” o Height: 78”

Alternate option: 10x10-Rollup Door: CTK RM C1-1 would have to move lots of cabinets prior to arrival if we use this doorway.

o Width: 120” o Height: 120”

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: 156” o Length: 72”

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

“Note 2: We the USAF do not include installation, training, tooling or the approval of additional options or accessories that are not part of the standard package or already listed above in the

38/70

CLIN 19:

ITEM NOUN: PRESS BRAKE, POWER O

NSN: 3441002772105

REQUISITION: FE660662930736

Specifications/Technical Characteristics:

These specifications have to be met or exceeded.

● 144 In. Diameter Holder Bed Length (Dimensions may vary up to 12” as long as they fit through the door and fit the available space listed below on page 2).

● 138 In. Distance Between Housings (Dimensions may vary up to 12” as long as they fit through the door and fit the available space listed below on page 2).

● 12 In. Max Die Space

● Mechanical

● Capacity - 90 Ton +

● 0.188 In. Thick x 12 Ft. With Mild Steel Plate Bending

● 3 In. Stroke

● 5 In. Adj Ram

● 1 Main Drive Motor - 15 Hp

● 1 Ram Adjustment Drive Motor - 7.5 Hp

● Ac220/440v 60 Hz 3 Phase

● Dual Chamber

Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist

235 Byron Street, (Bldg. 300) Suite 19A

39/70

● The existing source power available at the facility is o Volt: _220__ o Phase: __3_ o Frequency: _60__

● The machine must fit through a doorway with the following dimensions:

Preferred Option: Double Door way RM C1-2 easiest route with least amount of obstacles o Width: _12’__ o Height: _11’__ o Width: _14’__ o Height: _19’__

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: _5’__ o Length: _10’__

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

Note 2: We the USAF do not include installation, training, tooling or any additional options that are not part of the standard package in the above characteristics data.

40/70

CLIN 20:

ITEM NOUN: CUTTING SYSTEM, WATER JET

NSN: 3419015250135

REQUISITION: FEFE643393120002

Specifications/Technical Characteristics:

● MAXIMUM

OPERATING

PRESSURE

● MOUNTING TYPE

● CURRENT TYPE

● ELECTRIC MOTOR

HORSEPOWER

RATING

● TABLE OVERALL

LENGTH

● TABLE OVERALL

WIDTH

● TABLE

LONGITUDINAL

TRAVEL

● TABLE CROSS

TRAVEL

● PHASE

50000.0 POUNDS PER SQUARE INCH ABSOLUTE

FLOOR

AC

30.0

126.000 INCHES NOMINAL ; up to 2"-6" variance

65.000 INCHES NOMINAL ; up to 2"-6" variance

100.000 INCHES NOMINAL ; up to 2"-6" variance

55.000 INCHES NOMINAL ; up to 2"-6" variance

THREE

● SPECIAL FEATURES

▪ 380-440 VAC, 50-60HZ / 3 PHASE;

▪ 30HP AT 50,000PSI;

▪ 3/4 YD HOPPER;

▪ SYS DRIVE 1/2 HP;

▪ OPERATES UNATTENDED;

▪ NOISE LEVEL BELOW 80 DBA FOR SUBMERGED

CUTTING;

▪ SPEED 200 IPM;

▪ CNTRL CONSOLE 110V;

▪ REMOTE/LOCAL CONTROL

● FREQUENCY IN

HERTZ 50.0 AND 60.0

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

If not specified within the characteristics of the NSN, please provide the following information:

41/70 o Volt: ______480_____VAC o Phase: _____3________ o Frequency: _____60________Hz

● The machine must fit through a doorway with the following dimensions:

o Width: ___12____FEET o Height: ___8______ FEET

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: _____15_______FEET o Length: ______24_________FEET

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

Note 2: We the USAF do not include installation, training, tooling or any additional options that

42/70

CLIN 21:

ITEM NOUN: CUTTING SYSTEM, WATER JET

NSN: 3419015250135

REQUISITION: FE485592350006

Item Noun: CUTTING SYSTEM, WATER JET

Specifications/Technical Characteristics:

● MAXIMUM

OPERATING

PRESSURE

● MOUNTING TYPE

● CURRENT TYPE

● ELECTRIC MOTOR

HORSEPOWER

RATING

● TABLE OVERALL

LENGTH

● TABLE OVERALL

WIDTH

● TABLE

LONGITUDINAL

TRAVEL

● TABLE CROSS

TRAVEL

● PHASE

50000.0 POUNDS PER SQUARE INCH ABSOLUTE

FLOOR

AC

30.0

126.000 INCHES NOMINAL ; up to 2"-6" variance

65.000 INCHES NOMINAL ; up to 2"-6" variance

100.000 INCHES NOMINAL ; up to 2"-6" variance

55.000 INCHES NOMINAL ; up to 2"-6" variance

THREE

● SPECIAL FEATURES

▪ 380-440 VAC, 50-60HZ / 3 PHASE;

▪ 30HP AT 50,000PSI;

▪ 3/4 YD HOPPER;

▪ SYS DRIVE 1/2 HP;

▪ OPERATES UNATTENDED;

▪ NOISE LEVEL BELOW 80 DBA FOR SUBMERGED

CUTTING;

▪ SPEED 200 IPM;

▪ CNTRL CONSOLE 110V;

▪ REMOTE/LOCAL CONTROL

● FREQUENCY IN

HERTZ 50.0 AND 60.0

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

43/70

● The existing source power available at the facility is o Volt: _we have 230 or 480 volts_VAC o Phase: _3 phase_ o Frequency: _60 Hz

● The machine must fit through a doorway with the following dimensions:

o Width: _12_FEET o Height: _11 FEET

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: _16_FEET o Length: _22_FEET

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

Note 2: We the USAF do not include installation, training, tooling or any additional options that

44/70

CLIN 22:

ITEM NOUN: CUTTING SYSTEM, WATER JET

NSN: 3419015250135

REQUISITION: FE652102700014

Specifications/Technical Characteristics:

● MAXIMUM OPERATING

PRESSURE 50000.0 POUNDS PER SQUARE INCH ABSOLUTE

● MOUNTING TYPE FLOOR

● CURRENT TYPE AC

● ELECTRIC MOTOR

HORSEPOWER RATING 30.0

● TABLE OVERALL LENGTH 126.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE OVERALL WIDTH 65.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE LONGITUDINAL

TRAVEL 100.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE CROSS TRAVEL 55.000 INCHES NOMINAL ; up to 2"-6" variance

● PHASE THREE

● SPECIAL FEATURES

▪ 380-440 VAC, 50-60HZ / 3 PHASE;

▪ 30HP AT 50,000PSI;

▪ 3/4 YD HOPPER;

▪ SYS DRIVE 1/2 HP;

▪ OPERATES UNATTENDED;

▪ NOISE LEVEL BELOW 80 DBA FOR SUBMERGED CUTTING;

▪ SPEED 200 IPM;

▪ CNTRL CONSOLE 110V;

▪ REMOTE/LOCAL CONTROL

● FREQUENCY IN HERTZ 50.0 AND 60.0

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

45/70

● The existing source power available at the facility is o Volt: ___308__VAC o Phase: __3____ o Frequency: __50/60___Hz

● The machine must fit through a doorway with the following dimensions:

o Width: _12__FEET o Height: _12___FEET

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: __25____ FEET o Length: __25_____ FEET

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

Note 2: We the USAF do not include installation, training, tooling or any additional options that are

46/70

CLIN 23:

ITEM NOUN: CUTTING SYSTEM, WATER JET

NSN: 3419015250135

REQUISITION: FE447911880021

Specifications/Technical Characteristics:

● MAXIMUM

OPERATING

PRESSURE

● MOUNTING TYPE

● CURRENT TYPE

● ELECTRIC MOTOR

HORSEPOWER

RATING

● TABLE OVERALL

LENGTH

● TABLE OVERALL

WIDTH

● TABLE

LONGITUDINAL

TRAVEL

● TABLE CROSS

TRAVEL

● PHASE

50000.0 POUNDS PER SQUARE INCH ABSOLUTE

FLOOR

AC

30.0

126.000 INCHES NOMINAL ; up to 2"-6" variance

65.000 INCHES NOMINAL ; up to 2"-6" variance

100.000 INCHES NOMINAL ; up to 2"-6" variance

55.000 INCHES NOMINAL ; up to 2"-6" variance

THREE

● SPECIAL FEATURES

▪ 380-440 VAC, 50-60HZ / 3 PHASE;

▪ 30HP AT 50,000PSI;

▪ 3/4 YD HOPPER;

▪ SYS DRIVE 1/2 HP;

▪ OPERATES UNATTENDED;

▪ NOISE LEVEL BELOW 80 DBA FOR SUBMERGED

CUTTING;

▪ SPEED 200 IPM;

▪ CNTRL CONSOLE 110V;

▪ REMOTE/LOCAL CONTROL

● FREQUENCY IN

HERTZ 50.0 AND 60.0

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

If not specified within the characteristics of the NSN, please provide the following information:

47/70 o Volt: ___480______VAC o Phase: _____3________ o Frequency: ___60________Hz

● The machine must fit through a doorway with the following dimensions:

o Width: __12___FEET o Height: ___12____ FEET

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: _____21_____FEET o Length: ______21_______FEET

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

Note 2: We the USAF do not include installation, training, tooling or any additional options that

48/70

CLIN 24:

ITEM NOUN: CUTTING SYSTEM, WATER JET

NSN: 3419015250135

REQUISITION: FE649282750023

Specifications/Technical Characteristics:

● MAXIMUM OPERATING

PRESSURE 50000.0 POUNDS PER SQUARE INCH ABSOLUTE

● MOUNTING TYPE FLOOR

● CURRENT TYPE AC

● ELECTRIC MOTOR

HORSEPOWER RATING 30.0

● TABLE OVERALL LENGTH 126.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE OVERALL WIDTH 65.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE LONGITUDINAL

TRAVEL 100.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE CROSS TRAVEL 55.000 INCHES NOMINAL ; up to 2"-6" variance

● PHASE THREE

● SPECIAL FEATURES

▪ 380-440 VAC, 50-60HZ / 3 PHASE;

▪ 30HP AT 50,000PSI;

▪ 3/4 YD HOPPER;

▪ SYS DRIVE 1/2 HP;

▪ OPERATES UNATTENDED;

▪ NOISE LEVEL BELOW 80 DBA FOR SUBMERGED CUTTING;

▪ SPEED 200 IPM;

▪ CNTRL CONSOLE 110V;

▪ REMOTE/LOCAL CONTROL

● FREQUENCY IN HERTZ 50.0 AND 60.0

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

49/70

● The existing source power available at the facility is o Volt: _____440______VAC o Phase: ______3_______ o Frequency: ______60_______Hz

● The machine must fit through a doorway with the following dimensions:

o Width: ___10____FEET o Height: ____12_____ FEET

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: ______Unlimited______FEET o Length: _______Unlimited________FEET

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

Note 2: We the USAF do not include installation, training, tooling or any additional options that are

50/70

CLIN 25:

ITEM NOUN: CUTTING SYSTEM, WATER JET

NSN: 3419015250135

REQUISITION: FE614251210024

Specifications/Technical Characteristics:

● MAXIMUM OPERATING

PRESSURE 50000.0 POUNDS PER SQUARE INCH ABSOLUTE

● MOUNTING TYPE FLOOR

● CURRENT TYPE AC

● ELECTRIC MOTOR

HORSEPOWER RATING 30.0

● TABLE OVERALL LENGTH 126.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE OVERALL WIDTH 65.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE LONGITUDINAL

TRAVEL 100.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE CROSS TRAVEL 55.000 INCHES NOMINAL ; up to 2"-6" variance

● PHASE THREE

● SPECIAL FEATURES

▪ 380-440 VAC, 50-60HZ / 3 PHASE;

▪ 30HP AT 50,000PSI;

▪ 3/4 YD HOPPER;

▪ SYS DRIVE 1/2 HP;

▪ OPERATES UNATTENDED;

▪ NOISE LEVEL BELOW 80 DBA FOR SUBMERGED CUTTING;

▪ SPEED 200 IPM;

▪ CNTRL CONSOLE 110V;

▪ REMOTE/LOCAL CONTROL

● FREQUENCY IN HERTZ 50.0 AND 60.0

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

51/70

● The existing source power available at the facility is o Volt:480 VAC o Phase: 3 o Frequency: 60 Hz

● The machine must fit through a doorway with the following dimensions:

o Width: 12 FEET o Height: 12 FEET

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: 9 FEET o Length: 15 FEET

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

Note 2: We the USAF do not include installation, training, tooling or any additional options that are

52/70

CLIN 26:

ITEM NOUN: CUTTING SYSTEM, WATER JET

NSN: 3419015250135

REQUISITION: FE302901810042

Specifications/Technical Characteristics:

● MAXIMUM

OPERATING

PRESSURE

● MOUNTING TYPE

● CURRENT TYPE

● ELECTRIC MOTOR

HORSEPOWER

RATING

● TABLE OVERALL

LENGTH

● TABLE OVERALL

WIDTH

● TABLE

LONGITUDINAL

TRAVEL

● TABLE CROSS

TRAVEL

● PHASE

50000.0 POUNDS PER SQUARE INCH ABSOLUTE

FLOOR

AC

30.0

126.000 INCHES NOMINAL ; up to 2"-6" variance

65.000 INCHES NOMINAL ; up to 2"-6" variance

100.000 INCHES NOMINAL ; up to 2"-6" variance

55.000 INCHES NOMINAL ; up to 2"-6" variance

THREE

● SPECIAL FEATURES

▪ 380-440 VAC, 50-60HZ / 3 PHASE;

▪ 30HP AT 50,000PSI;

▪ 3/4 YD HOPPER;

▪ SYS DRIVE 1/2 HP;

▪ OPERATES UNATTENDED;

▪ NOISE LEVEL BELOW 80 DBA FOR SUBMERGED

CUTTING;

▪ SPEED 200 IPM;

▪ CNTRL CONSOLE 110V;

▪ REMOTE/LOCAL CONTROL

● FREQUENCY IN

HERTZ 50.0 AND 60.0

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

If not specified within the characteristics of the NSN, please provide the following information:

53/70 o Volt: _____440______VAC o Phase: ____3_________ o Frequency: ____60_________Hz

● The machine must fit through a doorway with the following dimensions:

o Width: __14_____FEET o Height: __7_______ FEET

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: ____21________FEET o Length: ____30___________FEET

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

Note 2: We the USAF do not include installation, training, tooling or any additional options that

54/70

CLIN 27:

ITEM NOUN: CUTTING SYSTEM, WATER JET

NSN: 3419015250135

REQUISITION: FE460000870088

Specifications/Technical Characteristics:

● MAXIMUM OPERATING

PRESSURE 50000.0 POUNDS PER SQUARE INCH ABSOLUTE

● MOUNTING TYPE FLOOR

● CURRENT TYPE AC

● ELECTRIC MOTOR

HORSEPOWER RATING 30.0

● TABLE OVERALL LENGTH 126.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE OVERALL WIDTH 65.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE LONGITUDINAL

TRAVEL 100.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE CROSS TRAVEL 55.000 INCHES NOMINAL ; up to 2"-6" variance

● PHASE THREE

● SPECIAL FEATURES

▪ 380-440 VAC, 50-60HZ / 3 PHASE;

▪ 30HP AT 50,000PSI;

▪ 3/4 YD HOPPER;

▪ SYS DRIVE 1/2 HP;

▪ OPERATES UNATTENDED;

▪ NOISE LEVEL BELOW 80 DBA FOR SUBMERGED CUTTING;

▪ SPEED 200 IPM;

▪ CNTRL CONSOLE 110V;

▪ REMOTE/LOCAL CONTROL

● FREQUENCY IN HERTZ 50.0 AND 60.0

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

55/70

● The existing source power available at the facility is o Volt: 480 VAC o Phase: 3 o Frequency: 60 Hz

● The machine must fit through a doorway with the following dimensions:

o Width: 10 FEET o Height: 10 FEET

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: 15 FEET o Length: 15 FEET

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

Note 2: We the USAF do not include installation, training, tooling or any additional options that are

56/70

CLIN 28:

ITEM NOUN: CUTTING SYSTEM, WATER JET

NSN: 3419015250135

REQUISITION: FE611213410119

Specifications/Technical Characteristics:

● MAXIMUM OPERATING

PRESSURE 50000.0 POUNDS PER SQUARE INCH ABSOLUTE

● MOUNTING TYPE FLOOR

● CURRENT TYPE AC

● ELECTRIC MOTOR

HORSEPOWER RATING 30.0

● TABLE OVERALL LENGTH 126.000 INCHES NOMINAL; up to 2"-6" variance

● TABLE OVERALL WIDTH 65.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE LONGITUDINAL

TRAVEL 100.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE CROSS TRAVEL 55.000 INCHES NOMINAL ; up to 2"-6" variance

● PHASE THREE

● SPECIAL FEATURES

▪ 380-440 VAC, 50-60HZ / 3 PHASE;

▪ 30HP AT 50,000PSI;

▪ 3/4 YD HOPPER;

▪ SYS DRIVE 1/2 HP;

▪ OPERATES UNATTENDED;

▪ NOISE LEVEL BELOW 80 DBA FOR SUBMERGED CUTTING;

▪ SPEED 200 IPM;

▪ CNTRL CONSOLE 110V;

▪ REMOTE/LOCAL CONTROL

● FREQUENCY IN HERTZ 50.0 AND 60.0

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

57/70

● The existing source power available at the facility is o Volt: ____480_______VAC o Phase: ______3_______ o Frequency: ______60_______Hz

● The machine must fit through a doorway with the following dimensions:

o Width: ___12____FEET o Height: ___12 3/4______ FEET

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: ____23’ 7”________FEET o Length: ____37’ 1 ½”______FEET

Note 1: This will be an open competitive competition and the source of supply will not be determined until the vendor quotes and technical acceptability is reviewed by the contracting agency.

Note 2: We the USAF do not include installation, training, tooling or any additional options that are

58/70

CLIN 29:

ITEM NOUN: CUTTING SYSTEM, WATER JET

NSN: 3419015250135

REQUISITION: FE558792310124

Specifications/Technical Characteristics:

● MAXIMUM OPERATING

PRESSURE 50000.0 POUNDS PER SQUARE INCH ABSOLUTE

● MOUNTING TYPE FLOOR

● CURRENT TYPE AC

● ELECTRIC MOTOR

HORSEPOWER RATING 30.0

● TABLE OVERALL LENGTH 126.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE OVERALL WIDTH 65.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE LONGITUDINAL

TRAVEL 100.000 INCHES NOMINAL ; up to 2"-6" variance

● TABLE CROSS TRAVEL 55.000 INCHES NOMINAL ; up to 2"-6" variance

● PHASE THREE

● SPECIAL FEATURES

▪ 380-440 VAC, 50-60HZ / 3 PHASE;

▪ 30HP AT 50,000PSI;

▪ 3/4 YD HOPPER;

▪ SYS DRIVE 1/2 HP;

▪ OPERATES UNATTENDED;

▪ NOISE LEVEL BELOW 80 DBA FOR SUBMERGED CUTTING;

▪ SPEED 200 IPM;

▪ CNTRL CONSOLE 110V;

▪ REMOTE/LOCAL CONTROL

● FREQUENCY IN HERTZ 50.0 AND 60.0

● Two (2) hard copies and one (1) electronic copy of technical data shall be provided with the machine.

● Shipping address for electronic technical data packages is:

Attn: Brian Roberson, Equip. Specialist 235 Byron Street, (Bldg. 300) Suite 19A Robins AFB, GA 31098-1813

59/70

● The existing source power available at the facility is o Volt: 440 V o Phase: 3 Phase o Frequency: 50/60Hz

● The machine must fit through a doorway with the following dimensions:

o Width: 150 FEET o Height: 30 FEET

● Available floor space for equipment width by length to include required operator workspace and OSHA required access clearances to service panels.

o Width: 26 FEET o Length: 26 FEET

60/70

CLIN 30:

ITEM NOUN: CUTTING SYSTEM, WATER JET

NSN: 3419015250135

REQUISITION: FE620192110159

Specifications/Technical Characteristics:

● MAXIMUM OPERATING

PRESSURE 50000.0 POUNDS PER SQUARE INCH ABSOLUTE

● MOUNTING TYPE FLOOR

● CURRENT TYPE AC

● ELECTRIC MOTOR

HORSEPOWER RATING…