Attachment 003 Colonnade Repair Drawings.pdf
PDF 21 MB Posted
- Attached to
- Colonnade Repair - Las Cruces NM
- Solicitation number
- 12805B24R0010
About this file
This document provides details for a federal construction contract solicitation for colonnade repair work at a facility in Las Cruces, New Mexico. The solicitation seeks offers for repair of colonnades at Wooton Hall located at 2995 Knox Street, with a mandatory site visit scheduled for February 22, 2024 at 9:00 AM Mountain Time. Offerors must register for the site visit by emailing Christopher Turner by February 20 with company and attendee information. No PPE is required for the site visit, but long pants, closed-toe shoes, and a valid US driver's license are recommended. The solicitation is being conducted by the Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery Plains Area.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
WOOTON HALL COLONNADE REPAIR
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
TITLE SHEET
T100 1 612/28/23
REH
REH
FEJ 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
3723-A
XXX
XXX
XXX
XXX
RANGE MANAGEMENT RESEARCH
2995 KNOX STREET
LAS CRUCES, NM 88003
PROJECT LOCATION
LAS CRUCES
CONTRACT NO:12805B23D0001
AGRICULTURAL RESEARCH SERVICE
U.S. DEPARTMENT OF AGRICULTURE
RANGE MANAGEMENT RESEARCH
WOOTON HALL COLONNADE REPAIR
ASSET #623515B001
LAS CRUCES, NEW MEXICO
DRAWING NO.SHEET NO. TITLE
T100
AD100
AD200
AD201
A100
A200
TITLE SHEET
EXISTING COLONNADE PLAN DEMOLITION
EXISTING COLONNADE DETAILS
REFERENCE PHOTOS
COLONNADE PLAN
DETAILS
NO SCALEVICINITY MAP
N
INDEX OF DRAWINGS LOCATION MAP NO SCALE
N
ORDER NO:12805B23F0260
PROJECT
LOCATION
BID DESCRIPTION
BASE BID:
ALL WORK ASSOCIATED WITH UNDERPINNING THE SOUTH COLONNADE AS
REQUIRED TO RESTORE THE COLONNADE TO ITS ORIGINAL VERTICAL
POSITION. THE COLONNADE STRUCTURE HAS SETTLED AND ROTATED TO
THE SOUTH TO AN APPROXIMATE .26 DEGREE ANGLE CREATING A 1" GAP,
AT ITS TOP, FROM THE MAIN WOOTON HALL STRUCTURE.
BID ALTERNATE #1:
ALL WORK ASSOCIATED WITH UNDERPINNING THE WEST COLONNADE AS
REQUIRED TO RESTORE THE COLONNADE TO ITS ORIGINAL VERTICAL
POSITION. THE COLONNADE STRUCTURE HAS SETTLED AND ROTATED TO
THE WEST TO AN APPROXIMATE .26 DEGREE ANGLE CREATING A 1" GAP, AT
ITS TOP, FROM THE MAIN WOOTON HALL STRUCTURE.
BASE BID AND BID ALTERNATE CONTAIN:
DEMOLITION OF EXISTING CONCRETE SIDEWALK, INSTALLATION OF
HYDRAULIC PIERS UNDER COLONNADE FOOTINGS TO RESTORE THE
COLONNADES TO ORIGINAL POSITION, INSTALLATION OF NEW CONCRETE
SIDEWALKS, MINOR REPAIR OF EXTERIOR FINISHES, AND INSTALLATION OF
SEALANT TO SEAL OPENINGS.
jferguson
2' -0
14'-9"+/-
16'-0"+/-
2' -0
2'
-0
2' -0
2'-0" 2'-0" 2'-0" 2'-0"
STREET CURB. PROTECT DURING CONSTRUCTION
ACTIVITIES. RESTORE TO ORIGINAL CONDITION IF
DAMAGED BY CONSTRUCTION ACTIVITIES.
SAWCUT ALONG EXISTING
CONTROL JOINT AND REMOVE
EXISTING 4" REINFORCED
(6"X6"X#10X#10 W.W.M.)
CONCRETE SIDEWALK TO
EXTENTS INDICATED.
SAWCUT AND REMOVE
EXISTING 4" REINFORCED
(6"X6"X#10X#10 W.W.M.)
CONCRETE SIDEWALK TO
EXTENTS INDICATED.
11'-8"+/-
134'-8"+/-
24'-1 3/8"
'-3
/4
COLONNADE STRUCTURE
SEE DETAIL 1/AD200
COLONNADE STRUCTURE
SEE DETAIL 1/AD200
WOOTON HALL
EXISTING CAST IRON TREE GRATES,
DELIVER TO OWNER FOR STORAGE
ON SITE TYPICAL OF 2.
16'-10"+/- 8'-0
6' -0
3'-0"+/-
6'
REMOVE EXISTING SOLID
STEEL GRATE COVER.
TYPICAL OF 4.
REMOVE EXISTING CONCRETE DRAINAGE SWALE COMPLETE
TO FLUSH WITH THE BACK OF STREET CURB. TYPICAL OF 4.
REMOVE EXISTING 4" REINFORCED (6"X6"X#10X#10 W.M.)
CONCRETE SIDEWALK TO EXTENTS INDICATED. RETAIN
EXISTING GRANULAR BASE.
EXISTING CONCRETE SIDEWALK
TO REMAIN IN PLACE. PROTECT
DURING CONSTRUCTION
ACTIVITIES.
EXISTING CONCRETE SIDEWALK
TO REMAIN IN PLACE. PROTECT
DURING CONSTRUCTION
ACTIVITIES.
EXISTING CONCRETE SIDEWALK
TO REMAIN IN PLACE. PROTECT
DURING CONSTRUCTION
ACTIVITIES.
0'
-6
149'-9"+/-
GRANULAR GROUND COVER. MAINTAIN
AND PROTECT FROM CONTAMINATION OF
CONSTRUCTION DEBRIS.
STREET CURB. PROTECT DURING
CONSTRUCTION ACTIVITIES. RESTORE
TO ORIGINAL CONDITION IF DAMAGED
BY CONSTRUCTION ACTIVITIES.
REMOVE GRANULAR BASE AND ADDITIONAL SOILS AS REQUIRED
TO INSTALL UNDERPINNING SYSTEM. STOCKPILE GRANULAR BASE
AND SOILS FOR REINSTALLATION AFTER UNDERPINNING IS
INSTALLED.
REMOVE GRANULAR BASE AND ADDITIONAL SOILS AS REQUIRED
TO INSTALL UNDERPINNING SYSTEM. STOCKPILE GRANULAR BASE
AND SOILS FOR REINSTALLATION AFTER UNDERPINNING IS
INSTALLED. TYPICAL AT 12 LOCATIONS.
REMOVE EXISTING SOLID
STEEL GRATE COVER.
TYPICAL OF 3.
SAWCUT ALONG EXISTING
CONTROL JOINT AND REMOVE
EXISTING 4" REINFORCED
(6"X6"X#10X#10 W.W.M.)
CONCRETE SIDEWALK TO
EXTENTS INDICATED.
BASE BID: ALL WORK ASSOCIATED WITH THE SOUTH COLONNADE.
REMOVE EXISTING 4" REINFORCED (6"X6"X#10X#10 W.M.)
CONCRETE SIDEWALK TO EXTENTS INDICATED. RETAIN
EXISTING GRANULAR BASE.
GRANULAR GROUND COVER.
MAINTAIN AND PROTECT FROM
CONTAMINATION OF
CONSTRUCTION DEBRIS.
BID ALTERNATE #1: ALL WORK ASSOCIATED WITH THE WEST COLONNADE.
EXISTING
CONTROL
JOINT
'-8
EXISTING CONTROL JOINT
FRENGER STREET
KN
O
X
ST
R
EE
T
S-1
S-2
S-3
S-4 S-5
S-6
W-3 W-1
W-2
W-4
S-4 PHOTOGRAPH KEY SEE SHEET AD201 FOR
PHOTOGRAPHS OF TYPICAL CONDITIONS
LEGEND
SEWER CLEANOUTS.
PROTECT DURING
CONSTRUCTION
SEWER NEUTRALIZATION
SUMP TO REMAIN. PROTECT
DURING WORK.
6' -0
16'
BUILDING GROUNDS TO REMAIN.
REINSTALL INTO NEW WORK
BUILDING GROUNDS TO REMAIN.
REINSTALL INTO NEW WORK
6' -6
W-5
S-9
S-7
S-8
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
WOOTON HALL COLONNADE REPAIR
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
EXISTING COLONNADE PLAN DEMOLITION
AD100
2 612/28/23
REH
REH
FEJ 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
3723-A
XXX
XXX
XXX
XXX
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
SCALE:
EXISTING COLONNADE PLAN DEMOLITION
1/8" = 1'-0"
AD100
Stamp
BOTTOM OF FOUNDATION
-3'-0"± (3881.5') B.F.F.
WOOTON HALL F.F.E.
0'-0"(3884.5')
TOP OF WALKWAY
VARIES 8"± TYPICAL
7'- 5"
7'-
0"
'-0
1'-0"±
2'-0"±
BOTTOM OF FOUNDATION
-3'-0"(3881.5') B.F.F.
F.F.E.
0'-0"(3884.5')
TOP OF WALKWAY
VARIES
1'- 0"
3'-4"±
EXISTING PRECAST CAP
EXISTING (2) CONT. #5 IN
KNOCK OUT BOND BEAM
EXISTING SOLID
FILLED 12" CMU
EXISTING STUCCO FINISH
EXISTING (2) #8 VERTICAL
BAR EACH CELL
EXISTING PRECAST TRIM
EXISTING STONE VENEER
EXISTING METAL TRIM
EXISTING 4" WALKWAY SLAB TO
BE DEMOLISHED TO EXTENTS
SHOWN ON SHEET AD100
EXISTING DOWELS
EXISTING (3) #4 BARS CONT # 4 @ 24"O.C.
TRANS.. MIN. (2) TRANS BARS EA.
PER PILASTER
EXISTING (2) #8 VERTICAL
BAR EACH CELL
EXISTING #8 @ 12" O.C. VERTICAL
EXISTING STUCCO FINISH
EXISTING PRECAST TRIM
EXISTING MASONRY VENEER
EXISTING SOLID
FILLED 12" CMU
EXISTING 4" WALKWAY SLAB
EXISTING (3) #4 BARS CONT # 4 @ 24"O.C.
TRANS.. MIN. (2) TRANS BARS EA.
PER PILASTER
EXISTING DOWELS
EXISTING PAINTED 8"x2"x14" STEEL TUBE
TRELLIS MEMBERS @ 24" O.C. TYPICAL.
EXISTING PRECAST CAP
EXISTING (2) CONT. #5 IN
KNOCK OUT BOND BEAM
REMOVE ALL EXISTING
SEALANT AND BACKER
RODS COMPLETE
EXISTING STUCCO FINISH
AT BUILDING
THE INTENT OF THIS PROJECT IS TO CORRECT AND STABILIZE THE ROTATIONAL FAILURE OF THE
SOUTH AND WEST COLONNADE STRUCTURES. BOTH STRUCTURES HAVE AN APPROXIMATE .5°
ROTATIONAL FAILURE THAT HAS PRODUCED A 0" TO 1" SEPARATION FROM THE MAIN WOOTON HALL
STRUCTURE.
NOTE:
EXISTING EXTERIOR WALL
OF WOOTON HALL
RETAIN EXISTING GRANULAR FILL
RETAIN EXISTING COMPACTED SOILS
.26°±
90° VERTICAL ORIGINAL
COLONNADE POSITION
.5°± ROTATION FROM VERTICAL
SEE SHEET AD201 FOR PHOTOGRAPHS OF TYPICAL CONDITIONS
NOTE:
DRAWING IS FOR REFERENCE ONLY. INDICATES COLONNADE REINFORCING
NOTE:
ORIGINAL DESIGN DOCUMENTS INDICATE THAT THE
TRELLIS MEMBERS ARE ANCHORED TO STEEL PLATE
AS SHOWN. SITE FIELD INVESTIGATION REVEALS THAT,
IF THE MEMBERS WERE INSTALLED AS DESIGNED, THE
CONNECTION HAS FAILED. SEE PHOTOGRAPH S-3 ON
SHEET AD201.
NOTE:
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
WOOTON HALL COLONNADE REPAIR
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
EXISTING COLONNADE DETAILS
AD200
3 612/28/23
REH
REH
FEJ 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
3723-A
XXX
XXX
XXX
XXX
2'
SCALE: 1"=1'-0"
0 1' 3'
SCALE:
EXISTING COLANNADE SECTION
1" = 1'-0"
AD200 SCALE:
EXISTING TYPICAL COLANNADE REINFORCING ELEVATION
1" = 1'-0"
AD200
SOUTH COLONNADE
WEST COLONNADE
S-1 LOOKING EAST S-2 LOOKING AT WEST END S-3 LOOKING AT TRELLIS BAR SEPARATION S-4 LOOKING AT EAST END INTERIOR OF COLONNADE S-5 LOOKING AT EAST END
S-6 LOOKING WEST
W-1 LOOKING NORTH
W-3 LOOKING AT SOUTH END
W-2 LOOKING NORTH W-4 LOOKING SOUTH
SEPARATION SEPARATIONSEPARATION
SEPARATION
S-7 SEWER CLEANOUTS S-8 NEUTRALIZATION SUMP S-9 TYPICAL BUILDING GROUND
W-5 LOOKING SOUTH
TREES SHOWN IN PICTURES HAVE BEEN REMOVED FROM SITE
COMPLETE BY NMSU. SEE PICTURE W-5.
NOTE:
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
WOOTON HALL COLONNADE REPAIR
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
REFERENCE PHOTOS
AD201
4 612/28/23
REH
REH
FEJ 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
3723-A
XXX
XXX
XXX
XXX
2' -0
2'
-0
2'-0" 2'-0" 2'-0" 2'-0"
STREET CURB. PROTECT
DURING CONSTRUCTION
ACTIVITIES. RESTORE TO
ORIGINAL CONDITION IF
DAMAGED BY CONSTRUCTION
ACTIVITIES.
COLONNADE STRUCTURE SEE 5/A200
WOOTON HALL
PROVIDE NEW GRATE. SEE
DETAIL 3/A200. TYPICAL OF 3
8'-0
3'-0"+/-
6'
PROVIDE CONCRETE DRAINAGE SWALE TO FLUSH WITH THE
BACK OF STREET CURB. SEE DETAIL 4/A200. TYPICAL OF 4.
PROVIDE 10 MIL. VAPOR BARRIER, 6" REINFORCE
(6"X6"X#10X#10 W.M.) CONCRETE SIDEWALK TO EXTENTS
INDICATED. SEE DETAILS 1/A200 AND 2/A200
EXISTING CONCRETE SIDEWALK
TO REMAIN IN PLACE. PROTECT
DURING CONSTRUCTION
ACTIVITIES.
EXISTING CONCRETE SIDEWALK.
PROTECT DURING CONSTRUCTION
ACTIVITIES.
EXISTING CONCRETE SIDEWALK
TO REMAIN IN PLACE. PROTECT
DURING CONSTRUCTION
ACTIVITIES.
EXISTING GRANULAR GROUND COVER.
MAINTAIN AND PROTECT FROM
CONTAMINATION OF CONSTRUCTION DEBRIS.
STREET CURB. PROTECT DURING
CONSTRUCTION ACTIVITIES. RESTORE
TO ORIGINAL CONDITION IF DAMAGED
BY CONSTRUCTION ACTIVITIES.
PROVIDE COMPACTED FILL
(EXISTING AND NEW SOILS AS
REQUIRED) AND REINSTALL THE
GRANULAR BASE FROM STOCKPILE
AT PIER EXCAVATION.
BASE BID:
ALL WORK ASSOCIATED WITH UNDERPINNING THE SOUTH
COLONNADE AS REQUIRED TO RESTORE THE COLONNADE TO ITS
ORIGINAL VERTICAL POSITION. THE COLONNADE STRUCTURE HAS
SETTLED AND ROTATED TO THE SOUTH TO AN APPROXIMATE .26
DEGREE ANGLE CREATING A 1" GAP, AT ITS TOP, FROM THE MAIN
WOOTON HALL STRUCTURE.
EXISTING GRANULAR GROUND
COVER. MAINTAIN AND PROTECT
FROM CONTAMINATION OF
CONSTRUCTION DEBRIS.
BID ALTERNATE #1:
ALL WORK ASSOCIATED WITH UNDERPINNING THE WEST COLONNADE AS
REQUIRED TO RESTORE THE COLONNADE TO ITS ORIGINAL VERTICAL
POSITION. THE COLONNADE STRUCTURE HAS SETTLED AND ROTATED TO
THE WEST TO AN APPROXIMATE .26 DEGREE ANGLE CREATING A 1" GAP, AT
ITS TOP, FROM THE MAIN WOOTON HALL STRUCTURE.
P79 P80
P77 P78
P75 P76
P73 P74
P71 P72 P69 P70
P67 P68
P65 P66
P63 P64
P61 P62
P59 P60
P57 P58
P55 P56
P49
P3
P4
P1
P2
P7
P8
P5
P6
P11
P12
P9
P10
P15
P16
P13
P14
P19
P20
P17
P18
P23
P24
P21
P22
P27
P28
P25
P26
P31
P32
P29
P30
P35
P36
P33
P34
P39
P40
P37
P38
P43
P44
P41
P42
P47
P48
P45
P46
P51 P52
P50
PROVIDE 4" REINFORCE
(6"X6"X#10X#10 W.M.) CONCRETE
SIDEWALK TO EXTENTS INDICATED.
PROVIDE 12" EXPANSION MATERIAL
AND SEALANT WHERE NEW
CONCRETE ABUTS EXISTING AND
OTHER NEW CONCRETE OR
VERTICAL SURFACE.
5' -3
9'-6"+/-
PROVIDE 4" REINFORCE
(6"X6"X#10X#10 W.M.) CONCRETE
SIDEWALK TO EXTENTS INDICATED.
PROVIDE 12" EXPANSION MATERIAL
AND SEALANT WHERE NEW WALL
ABUTS EXISTING AND OTHER NEW
CONCRETE OR VERTICAL SURFACE.
2' -0
MATCH
EXISTING
ELEVATION
'-2
P53 P54
39.939°
T.O.S.: MATCH
EXISTING
ELEVATION
T.O.S.: MATCH
EXISTING
ELEVATION
T.O.S.: MATCH
EXISTING
ELEVATION
T.O.S.: MATCH
EXISTING
ELEVATION
PROVIDE NEW GRATE. SEE
DETAIL 3/A200. TYPICAL OF 4. PROVIDE COMPACTED FILL
(EXISTING AND NEW SOILS AS
REQUIRED) AND REINSTALL THE
GRANULAR BASE FROM STOCKPILE
AT PIER EXCAVATION.
T.O.S.: MATCH
EXISTING
ELEVATION
T.O.S.: MATCH
EXISTING
ELEVATION
SLOPE 2%
PROVIDE #3 x 16" DOWELS @ 24"O.C. SET INTO 1"DIA. x 4" DEEP CORED HOLE AT
EXISTING 4" SLAB. ANCHOR WITH MINIMUM
4000PSI EPOXY GROUT. PROVIDE DOWELS
AT NEW ADJACENT SLAB WHEN PLACED.
ESTIMATED COLUMN
LOAD=24,993LB's @ 2,777 PER
SQ/FT. TYPICAL OF (6). SEE
DETAIL 2/A100
ESTIMATED COLUMN
LOAD=54,710LB's @ 2,777 PER
SQ/FT. TYPICAL OF (2).
ESTIMATED COLUMN LOAD=24,993LB's
@ 2,777 PER LF. TYPICAL OF (6).
SEE DETAIL 2/A100
123'-8"+/-
TOTAL ESTIMATED WEIGHT OF SOUTH COLONNADE = 325,000 LBS
TOTAL ESTIMATED WEIGHT OF
WEST COLONNADE = 250,000
MATCH
EXISTING
ELEVATION
PROVIDE CONCRETE DRAINAGE
SWALE TO FLUSH WITH THE BACK
OF STREET CURB. SEE DETAIL
4/A200. TYPICAL OF 4.
EXISTING CURB CUT
EXISTING CURB CUT
11'-8"+/-
EXISTING
CONTROL
JOINT
'-1
/4
PROVIDE #3 x 16" DOWELS @ 24"O.C. SET INTO 1"DIA. x 4" DEEP CORED HOLE AT
EXISTING SLAB 4". ANCHOR WITH MINIMUM
4000PSI EPOXY GROUT. PROVIDE AT NEW
ADJACENT SLAB WHEN PLACED.
PROVIDE 4" REINFORCE
(6"X6"X#10X#10 W.M.) CONCRETE
SIDEWALK TO EXTENTS INDICATED.
PROVIDE 12" EXPANSION MATERIAL
AND SEALANT WHERE NEW WALL
ABUTS EXISTING AND OTHER NEW
CONCRETE OR VERTICAL SURFACE.
PROVIDE 4" CRUSHED LIMESTONE
GRANULAR FILL. (580 SQ/FT +/-)
PROVIDE 4" CRUSHED LIMESTONE
GRANULAR FILL. (750 SQ/FT+/-)
MATCH EXISTING CURB
CUT ELEVATION
CONTROL JOINTS @ 5' O.C. TYPICAL
CONTRACTOR SHALL COMPLETE PIER SCHEDULE
LOG ON SHEET A200.
NOTE:
MATCH EXISTING
CURB CUT
ELEVATION
T.O.S. TOP OF SLAB
P1 PIER NUMBER
SQ/FT SQUARE FOOT
LEGEND
A200
A200
'-6
P31
P32
P29
P30
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
WOOTON HALL COLONNADE REPAIR
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
COLONNADE PLAN
A100 5 612/28/23
REH
REH
FEJ 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
3723-A
XXX
XXX
XXX
XXX
EXCAVATION AREA AS REQUIRED
PIER AS SPECIFIED
OUTLINE OF
EXISTING
FOOTING
COLONNADE
STRUCTURE.REINFORCED
SOLID FILLED 12"X8"X16"
CMU BLOCK WITH STONE
MASONRY VENEER. SEE
5/A200
NEW SLAB LINE
SCALE: 3/8"=1'-0"
0 1' 2' 4' 8'
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
SCALE:
COLONNADE PLAN
1/8" = 1'-0"
A100
SCALE:
ENLARGED TYPICAL PLAN AT FOOTING
3/8" = 1'-0"
A100
SCALE:
COLONNADE WALKWAY DETAIL
1-1/2" = 1'-0"
A200
SCALE:
COLONNADE WALKWAY DETAIL @ COLUMN
1-1/2" = 1'-0"
A200
T.O. SLAB
MATCH EXISTING
2% SLOPE
6" x 6" x #10 x #10 W.W.M. CONT.
PROVIDE SEALANT AND 12"
EXPANSION MATERIAL
10 MIL VAPOR BARRIER
EXISTING GRANULAR BASE
EXISTING COMPACTED SOILS
PROVIDE LIGHT BROOM FINISH
PERPENDICULAR TO DIRECTION
OF TRAVEL
8"
LINE OF EXISTING BUILDING
T.O. SLAB
MATCH EXISTING
2% SLOPE
6" x 6" x #10 x #10 W.W.M. CONT.
(2) #4 CONT.
W/ #4 @ 48" O.C.
PROVIDE SEALANT AND 12"
EXPANSION MATERIAL
10 MIL VAPOR BARRIER
EXISTING COMPACTED SOILS
NEW 6" SLAB ON GRADE
PROVIDE LIGHT BROOM FINISH
PERPENDICULAR TO DIRECTION
OF TRAVEL
8"
LINE OF EXISTING BUILDING
PROVIDE SEALANT AND 12"
EXPANSION MATERIAL
(2) #4 CONT.
W/ #4 @ 48" O.C.
8"
8"
8"
EXISTING COLONNADE COLUMN
EXISTING COLONNADE FOOTING
8"
6" 6"
1'-9"6" 6"
10 MIL VAPOR BARRIER
EXISTING GRANULAR BASE
EXISTING COMPACTED SOILS
2'-0" 6" x 6" x #10 x #10 W.W.M. CONT.
NEW 6" SLAB ON GRADE
PROVIDE LIGHT BROOM FINISH
PERPENDICULAR TO DIRECTION
OF TRAVEL
TRENCH GRATE BASIS OF DESIGN:
DURA TECH MODEL: 20W24DI OR
APPROVED EQUAL.1 3 4" x 1 3 4" x14" ANGLE
CONT.
ANCHORS @ 16"O.C.
SCALE:
TRENCH AND GRATE DETAIL
1-1/2" = 1'-0"
A200
BOTTOM OF FOUNDATION
-3'-0"(3881.5') B.F.F.
F.F.E.
0'-0"(3884.5')
TOP OF WALKWAY
VARIES
7'- 5"
7'-
0"
'-0
EXISTING PRECAST CAP
EXISTING REINFORCED SOLID FILLED
12" CMU. SEE DETAIL 2/AD200
EXISTING STUCCO FINISH
EXISTING PRECAST TRIM
EXISTING MASONRY VENEER
EXISTING METAL TRIM
EXISTING PAINTED
STEEL 8"x2"x14" TUBE
PROVIDE NEW SEALANT AND
BACKER RODS CONT. AROUND
EXISTING TUBE STEEL.
EXISTING STUCCO FINISH
AT EXISTING BUILDING
1'-9"6" 6"
EXISTING GRANULAR BASE
SCALE:
CONCRETE DRAINAGE TROUGH DETAIL
1-1/2" = 1'-0"
A200
EXISTING COMPACTED SOILS
1" CHAMFER
(5) # 4 CONT.
W/#4 @ 24" O.C.
6" 6"
EXISTING SOILS EXCAVATION
FILL. CONTRACTOR SHALL
ENSURE TO NOT UNDERMINED
FOUNDATION DURING REPAIR
EXISTING GRANULAR BASE
EXCAVATION FILL
PROVIDE SEALANT AND 12"
EXPANSION MATERIAL
NEW 6" SLAB ON GRADE
PROVIDE LIGHT BROOM FINISH
PERPENDICULAR TO DIRECTION
OF TRAVEL
6" x 6" x #10 x #10 W.W.M. CONT.
(2) #4 CONT. W/ #4 @ 48" O.C.
EXISTING PRECAST CAP
EXISTING STUCCO FINISH
PROVIDE NEW SEALANT AND
BACKER RODS CONT. AT
JOINT BETWEEN COLONNADE
AND EXISTING BUILDING
SCALE:
COLONNADE SECTION
1" = 1'-0"
A200
SCALE:
COLONNADE BUILDING INTERSECTION DETAIL
1" = 1'-0"
A200
EXISTING EXTERIOR WALL
OF WOOTON HALL
EXISTING EXTERIOR WALL
OF WOOTON HALL
PROVIDE NEW SEALANT AND
BACKER RODS CONT. AT
JOINT BETWEEN COLONNADE
AND EXISTING BUILDING
EXISTING EXTERIOR WALL
OF WOOTON HALL
EXISTING COLONNADE WALL
EXISTING COLONNADE WALL
PLAN VIEW
SECTION VIEW
EXISTING STUCCO FINISH
EXISTING STUCCO FINISH
UNDERPINNING PIER SCHEDULE
PIER #
DESIGN DEPTH (IN FEET) INSTALLED DEPTH (IN FEET) AND RIGHT OF REFUSAL
DEPTH DEPTH RIGHT OF REFUSAL
SOUTH COLONNADE
P1 100' P2 100' P3 100' P4 100' P5 100' P6 100' P7 100' P8 100' P9 100' P10 100' P11 100' P12 100' P13 100' P14 100' P15 100' P16 100' P17 100' P18 100' P19 100' P20 100' P21 100' P22 100' P23 100' P24 100' P25 100' P26 100' P27 100' P28 100' P29 100' P30 100' P31 100' P32 100' P33 100' P34 100' P35 100' P36 100' P37 100' P38 100' P39 100' P40 100' P41 100' P42 100' P43 100' P44 100' P45 100' P46 100' P47 100' P48 100'
WEST COLONNADE
P49 100' P50 100' P51 100' P52 100' P53 100' P54 100' P55 100' P56 100' P57 100' P58 100' P59 100' P60 100' P61 100' P62 100' P63 100' P64 100' P65 100' P66 100' P67 100' P68 100' P69 100' P70 100' P71 100' P72 100' P73 100' P74 100' P75 100' P76 100' P77 100' P78 100' P79 100' P80 100'
(2) #4 CONT.
W/ #4 @ 48" O.C.
NEW UNDERPINNING PIER SYSTEM AS SPECIFIED
NEW FOUNDATION BRACKET
EXISTING SOILS EXCAVATION
FILL. CONTRACTOR SHALL
ENSURE TO NOT UNDERMINED
FOUNDATION DURING REPAIR
(2) #4 CONT. W/ #4 @ 48" O.C.
(2) #4 CONT W/ #4 @ 24" O.C.
2'-0" 2'-0"
EXISTING CURB
NEW DRAINAGE TROUGH
12" EXPANSION MATERIAL
WITH SEALANT
WATER FLOW
CONTRACTOR SHALL COMPLETE PIER SCHEDULE LOG ON SHEET
A200.
NOTE:
4" 6" x 6" x #10 x #10 W.W.M. CONT. 4" SLAB ON GRADE
PROVIDE LIGHT BROOM FINISH
PERPENDICULAR TO DIRECTION
OF TRAVEL
EXISTING GRANULAR BASE
EXISTING COMPACTED SOILS
SCALE:
TYPICAL SIDEWALK DETAIL
1" = 1'-0"
A200
CONTRACTOR SHALL ALLOW FOR REPAIR OF
50 SQUARE FEET OF STUCCO FINISH FOR
BASE BID AND BID ALTERNATE #1 FOR A
TOTAL OF 100 SQUARE FEET.
NOTE:
NEW UNDERPINNING PIER SYSTEM
AS SPECIFIED
NEW FOUNDATION BRACKET
REPLACE SOILS AND COMPACT
REPLACE GRANULAR BASE
SECTION AT CURB
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
WOOTON HALL COLONNADE REPAIR
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
DETAILS
A200 6 612/28/23
REH
REH
FEJ 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
3723-A
XXX
XXX
XXX
XXX
2'
SCALE: 1"=1'-0"
0 1' 3'
| Sheets and Views |
| T100 |
| AD100 |
| AD200 |
| AD201 |
| A100 |
| A200 |
File details come from the government source that posted it. Updated .