MAINTENANCE ENGINEERING ORDER

(AMCOM Reg. 750-2)

MEO NO.

DATE PAGE 1 of

TITLE Tolerances Unless otherwise noted, dimensions are in inches and tolerances are:

Fractional ………………… ± 1/32 Decimal ………………... ± 0.010 Angular ………………… ± ½°

APPLICABILITY CSI Critical Characteristic Affected?

Impact Statement Attached?

REFERENCES FOR RDECOM USE ONLY

DOCUMENT(S) AFFECTED

PURPOSE OR PROBLEM

PROJECT ENGINEER ENGINEERING REVIEW ENGINEERING RELEASE

MED FORM 5-DEC-09 1401-R-E

AR 70-62 •11 May 2016 B 3182

Apr 27, 2018 1

Heating and Cooling General Practices for Parts Installations (T700, T401, T401C, T701C, T701D)

Technical

INTERIM USE OF THIS MEO IS AUTHORIZED

UNTIL AFFECTED DOCUMENT IS UPDATED.

MEO CHANGE TYPE

4) Normal - Can be implemented with normal priorityPRIORITY IMPLEMENTATION CATEGORY

T700 DAX

DMWR 1-2840-248-1 Dated 30 Sept 2014 TTS 184158, MEC-B336926

DOCUMENT CHANGE IS REQUIRED Verification: Hands-On Table-Top None

Clarify general heating and cooling guidance. Heating and cooling instructions are mandatory when there is specified the use of an arbor press. There is a concern that unmeasured force applied by arbor press could be excessive and cause damage to parts.

BONHAM.ROBI

N.L.1229254100

Digitally signed by

BONHAM.ROBIN.L.12292541

Date: 2018.04.10 11:30:44 -05'00'

MCCORD.MATT

HEW.KIRKLAND.

1275198800

Digitally signed by

MCCORD.MATTHEW.KIRKLA

ND.1275198800

Date: 2018.04.10 11:57:40 -05'00'

Matthew McCord

HORN.REINHOL

D.J.1087783495

Digitally signed by

HORN.REINHOLD.J.1087783

Date: 2018.04.11 14:05:22 -05'00'

Robin L Bonham Reinhold Horn PUBLICATION CHANGE REQUEST: REQUEST THAT THE FOLLOWING DATA BE INCLUDED IN THE NEXT

CHANGE OR REVISION TO THE PUBLICATION IDENTIFIED ABOVE.

WP NO. PAGE

NO.

PARA-

GRAPH

FIGURE/

TABLE

NO.

CHANGES

(EXACT WORDING OF CHANGES MUST BE GIVEN)

3-411

3-21.ad.

(2)

REVISE step as follows:

"(2) Repair part is able to be installed easily (without excessive force or the use of an arbor press)."

Distribution Statement D:- Distribution authorized to Department of Defense and U.S. DoD contractors only to protect critical technology effective as of 26 June 2014. Other requests for this document must be referred to U.S. Army Aviation and Missile Research, Development and Engineering Center, ATTN: RDMR -AEM , Corpus Christi, TX 78419-5211