This file is a facility map and gas tank location diagram for Rock Island Arsenal Joint Manufacturing and Technology Center (RIAJMTC) buildings and bulk gas storage. The diagram shows detailed locations of nitrogen, oxygen, argon, propylene, and helium tanks across multiple buildings (208, 210, 212W, 220, 222, 230, 250, 299), including their capacities ranging from single cylinders up to 6,000 gallons.

The map includes a comprehensive table listing 25 gas tank installations with their building locations, gas types, capacities, tank ID numbers, mixer IDs, trifecta IDs, and vaporizer switch IDs. The layout shows various facility features including smoking shelters, elevators, ramps, safety equipment, and utility infrastructure. The diagram appears to be supporting documentation for a bulk gas supply contract, providing bidders with detailed information about tank locations and specifications across the JMTC facility.

View the file

Other files for this federal contract opportunity

Other files attached to Bulk Gases and Amendment 0001, newest first.
File Type Posted
W519TC25Q2041 Amendment 0001.pdf PDF
Attachment 1001 Map.pdf PDF
Attachment 1002 - estimated quantities.xlsx XLSX spreadsheet
W519TC25Q2041.pdf PDF
Attachment 0002 - SOW Bulk Gases PM and Repair.pdf PDF
Attachment 0001 - SOW Gases.pdf PDF
Attachment 0004 - Price Matrix for 25Q2041 Bulk Gas.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OUTSIDE WEST

OUTSIDE SOUTHEAST

OUTSIDE SOUTHEAST

OUTSIDE SOUTHEAST

OUTSIDE SOUTHEAST

6 OUTSIDE SOUTHEAST

8 OUTSIDE SOUTHWEST

9 OUTSIDE SOUTHEAST

10 OUTSIDE SOUTHEAST

16 OUTSIDE NORTHWEST

OUTSIDE EAST (S)

OUTSIDE EAST (N)

OUTSIDE EAST (S)

DISCONNECTED

OUTSIDE WEST

OUTSIDE WEST

OUTSIDE NORTH

INSIDE RM425

INSIDE RM401

OUTSIDE SOUTHWEST

OUTSIDE SOUTHWEST

OUTSIDE WEST

23 OUTSIDE WEST

24 OUTSIDE WEST

RIA 34437NITROGEN

OXYGEN RIA 34214

RIA 34215

RIA 34213

RIA 34226

RIA 35130

RIA 34222

RIA 34218

RIA 34217

RIA 34219

RIA 34220

RIA 34224

RIA 34223

RIA 34212

RIA 34211

RIA 34315

RIA 34341

RIA 35145

RIA 35146

RIA 34382

RIA 90414

RIA 90415

RIA 34590

RIA 35009

RIA 35236

RIA 34592

RIA 34589 NO ID#

NO ID#

NO ID#

RIA 34593

NO ID#

RIA 34591

NO ID#

NO ID#

NO ID#

MANUAL

MANUAL

MANUAL

MANUAL

MANUAL

RIA 90416

RIA 90410

OXYGEN

NITROGEN

NITROGEN

ARGON

NITROGEN

OXYGEN

ARGON

PROPYLENE

NITROGEN

OXYGEN

ARGON

OXYGEN

NITROGEN

PROPYLENE

NITROGEN

NITROGEN

ARGON/OXYGEN

HELIUM

ARGON

NITROGEN

NITROGEN

ARGON

NITROGEN

SWITCH ID#VAPORIZERTRIFECTA ID#MIXER ID#TANK ID#CAPACITYGASLOCATIONBLDG

212W

212W

212W

212W

208 INSIDE 208-B-M3

3,000 Gal

1,000 Gal

1,000 Gal

1,000 Gal

450 Gal

450 Gal

6,000 Gal

3,000 Gal

1,500 Gal

1,000 Gal

3,000 Gal

1,500 Gal

1,500 Gal

900 Gal

3,000 Gal

15-CYLS

6,000 Gal

1-CYL

1-CYL

12-CYLS

1,000 Gal

3,000 Gal

5,500 L

5,500 L

25-CYLS

90413/90414

34382/90415

3-40623/3-40624

90413/90414RIA 34215

X X

X X

X X

X

X X

X X X X X X X

X X

X

X X

X

X

X

PAD

XXX

X X X X X X

X

X

X

X

X

X X

X

X

X X

X

X

X

X

GRASS FIELD

#16

SHELTER

SMOKING

#17

SHELTER

SMOKING

S H

E L

T E

R S

M O

K

IN

G

S H

E L

T E

R S

M O

K

IN

G

S H

E L

T E

R S

M O

K

IN

G

S H

E L

T E

R S

M O

K

IN

G

S H

E L

T E

R S

M O

K

IN

G

#5

SHELTER

SMOKING

#21

SHELTER

SMOKING

#8

SHELTER

SMOKING

#7

SHELTER

SMOKING

#9

SHELTER

SMOKING

#18

SHELTER

SMOKING

#10

SHELTER

SMOKING

#11

SHELTER

SMOKING

#13

SHELTER

SMOKING

#19

SHELTER

SMOKING

P T

P T

P T

PT1

PT15

P T

P T

PT7

P T

P T

PT9

P T

P T

P T

PT27

PT28

P T

P T

P T

P T

P T

P T

P T

P T

P T

PT23

P T

PT46

P T

P T

P T

PT34

PT32

PT35

P T

P T

P T

P T

PT43

P T

P T

PT63

P T

P T

PT61

P T

PT20

P T

P T

P T

PT11

P T

PT10

DOORS

RAMP

RAMP

cage

WINDOW = 42"x48"

WINDOW = 42"x48"

Safety

9'WIDE x 12'h. ROLL-UP 9'WIDE x 12'h. ROLL-UP

WINDOW = 42"x48"

INSPECTION

cage

Safety

BREAK

AREA

H E

A T

E R

H E

A T

E R

TUNNEL

COVER

TUNNEL

COVERCOVER

TUNNEL

COVERCOVER

E L

E V

E L

E V

D R

O P

D O

W N

'w

X

T w

X

T

RAMP UP

PEDESTRIAN RAMP - DOWN

ELEVATOR

UP UP

E L

E V

A T

O R

RAMP - DOWN

3"/48"=6.3%

B L

D G

B L

D G

H20

H20

DO

W

N

U P

UP

U P

UP

UP

DO

W

N

U P

D N

UP

DO

W

N

DO

W

N

UP

DOWN

UP

U P

DO

W

N

UP

ELEVATOR

ELEVATOR

ELEVATOR

D F

PLATFORM

RAMP DOWN

WATER VALVES

HYD

HYD

RAMP

ROLL - UP

AC

COMMUNICATION

IT

IT

OPEN WELL

T48

T47

T10

T40

T41

T42RAISED CONCRETE

STEPPED

RAISED CONCRETE

STEPPED

RAISED CONCRETE

STEPPED

NEW PIT

SAME LEVEL

ELEC. EQUIP

FIRE HOSE

DN

DOCK

AREA WELL

D N

AREA WELL

HOLE

MAN

T O

B A

L C

O N

Y

DOCK

U P

T O

B A

L C

O N

Y U

P

UP

MANHOLE

MANHOLE

STEAM

TUNNEL

SAFETY

LADDER

LADDER

EXISTING

LADDERS

SAFETY

LADDERS

SAFETY

LADDERS

SAFETY

FIRE

ALARM

SUMMIT

BLDG

HEAT

ELECTRICAL

LO

UV

ER

S

LO

UV

ER

S

RAISED WALK

ELECT

AIR

MAKEUP

AIR

MAKEUP

AIR

MAKEUP

C O

N C

R E

T E

P L

A T

F O

R M

'-2

H

IG

H

DN

DN

DN

DN DN

SLOPE DOWN TO GRADE

L A

N D

IN

G

RAMP UP

TANK

TANK PIT

UP

U P

FIRE CONTROL

GAS LINES

GAS LINES

PROPYLENE

BACK UP

3000 GALLON

NITROGEN TANK

VT 6000 H2776

PROPYLENE

FLASH BACK

ARRESTER

98/2

BACK UP

BACK UP BOTTLES

OXYGEN

VS 3000 NC250

4-4-08

ARGON

1500 GALLON

NEW 10-06

GASES GASES GASES

File details come from the government source that posted it. Updated .